Academic literature on the topic 'Filtração Direta Ascendente'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Filtração Direta Ascendente.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Filtração Direta Ascendente"

1

Botari, Alexandre, and Luiz Di Bernardo. "Modelação matemática macroscópica da perda de carga e da remoção de sólidos suspensos totais na filtração direta ascendente." Engenharia Sanitaria e Ambiental 12, no. 2 (June 2007): 149–59. http://dx.doi.org/10.1590/s1413-41522007000200006.

Full text
Abstract:
A utilização de um modelo matemático permite a obtenção de condições otimizadas de operação, o que conduz à melhoria do controle e da previsão do processo de filtração. Os modelos matemáticos descrevem o processo de filtração através dos mecanismos de remoção de partículas que ocorre no meio filtrante. Este trabalho propõe a modelação matemática baseada nos modelos que descrevem macroscopicamente o processo de filtração e que incluem, por exemplo, o mecanismo de desprendimento de partículas do meio filtrante e a alteração da porosidade do material retido durante a filtração. O modelo desenvolvido foi adaptado para a aplicação à filtração direta ascendente em material granular de areia grossa inserido no processo de dupla filtração.
APA, Harvard, Vancouver, ISO, and other styles
2

Botari, Alexandre, and Luiz Di Bernardo. "Modelação da perda de carga na filtração direta ascendente em meio granular de areia grossa e pedregulho." Engenharia Sanitaria e Ambiental 14, no. 2 (June 2009): 245–56. http://dx.doi.org/10.1590/s1413-41522009000200012.

Full text
Abstract:
Compreender e quantificar os mecanismos relacionados à perda de carga e à remoção de partículas em um meio filtrante granular é de importância fundamental para o estudo do processo da filtração. Este trabalho apresenta o desenvolvimento dos modelos de perda de carga na filtração em meios porosos e a proposição da modelação matemática semiempírica da perda de carga para meios filtrantes limpos e do desenvolvimento do perfil de perda de carga ao longo do tempo de filtração a partir da equação de Ergun. Objetivou-se a determinação dos valores das constantes da equação de Ergun para meio granular de areia grossa e pedregulho. Alguns exemplos de aplicação dessa modelação matemática são também apresentados e discutidos pelos autores com base em dados experimentais obtidos em uma estação piloto de dupla filtração.
APA, Harvard, Vancouver, ISO, and other styles
3

Castilhos Junior, Armando Borges de, Ramon Lucas Dalsasso, and Fabio Rohers. "Pré-tratamento de lixiviados de aterros sanitários por filtração direta ascendente e coluna de carvão ativado." Engenharia Sanitaria e Ambiental 15, no. 4 (December 2010): 385–92. http://dx.doi.org/10.1590/s1413-41522010000400011.

Full text
Abstract:
Vários problemas ambientais no Brasil decorrem do acelerado crescimento dos setores produtivos e, consequentemente, da multiplicidade dos resíduos sólidos urbanos gerados. A disposição destes em aterros sanitários é prática comum; entretanto, essa deposição requer medidas de proteção ambiental, incluindo o tratamento dos lixiviados. Este trabalho, conduzido em filtros de areia e coluna de carvão ativado, trata de proposta de tratamento físico-químico do lixiviado como alternativa ao processo biológico. No que se refere ao processo de filtração, observaram-se reduções de até 74% para DQO, 47% para DBO, 93% para cor, 90% para amônia e aumento de 0,3 para 0,9 na relação DBO5/DQO. Constataram-se limitações com relação à duração das carreiras de filtração, para o que se sugere avaliar outras granulometrias de areia e até mesmo tecnologias de tratamento.
APA, Harvard, Vancouver, ISO, and other styles
4

Lima, José Airton Pereira, and José Capelo-Neto. "Dupla filtração modificada utilizando filtro de pressão a montante de filtro ascendente no tratamento de águas eutrofizadas." Engenharia Sanitaria e Ambiental 20, no. 1 (March 2015): 89–102. http://dx.doi.org/10.1590/s1413-41522015020000110892.

Full text
Abstract:
A implantação de uma unidade de pré-tratamento a montante de um filtro ascendente (FA) existente objetiva condicionar a água bruta eutrofizada à capacidade de tratamento do FA. Essa solução esbarra na necessidade de se instalar essa unidade de pré-tratamento com cota mais elevada que o filtro a jusante. Nesta pesquisa, a instalação de um filtro de pressão de fluxo descendente possibilitou a eliminação do problema do desnível geométrico e a adequação da água bruta com elevada presença de fitoplâncton às limitações da filtração direta ascendente (FDA). O pré-filtro de pressão com melhor eficiência, o PFP1, apresentou uma remoção de 50% de cor aparente e 63% de turbidez. A eficiência global do sistema PFP/FA foi satisfatória, apresentando turbidez final inferior a 0,5 uT, cor aparente em torno de 5 uH, além de reduzir as perdas da água tratada de 11,7 para 4,5%.
APA, Harvard, Vancouver, ISO, and other styles
5

Botari, Alexandre, Luiz Di Bernardo, and Angela Di Bernardo Dantas. "Análise e modelação matemática da interação entre partículas na filtração direta utilizando a teoria coloidal." Engenharia Sanitaria e Ambiental 17, no. 1 (March 2012): 81–94. http://dx.doi.org/10.1590/s1413-41522012000100012.

Full text
Abstract:
Este trabalho utilizou a teoria coloidal para descrever o comportamento físico pelo balanço de forças e balanço de energia de complexos coloidais na água bruta e daqueles formados durante a filtração direta em escoamento ascendente. Nele são descritos os perfis de energia de interação entre as superfícies dos colóides para três geometrias: esférica, plana e cilíndrica; e quatro arranjos de interação entre as superfícies: dois cilindros, dois planos, duas esferas e uma esfera e um plano. Duas situações foram analisadas, antes e após a desestabilização eletrostática pela ação de sulfato de alumínio em águas de estudo contendo caulinita, utilizando-se a modelação e análise pela teoria DLVO (das iniciais de Derjarguin-Landau-Verwey-Overbeek) modificada, ou XDLVO, que inclui à abordagem tradicional das forças da dupla camada elétrica (DCE), forças de atração de superfície ou London-van der Waals (LvdW), forças estéricas, força hidrofóbica e forças de outras origens no cálculo do balanço de forças, a saber: repulsão molecular, denominada repulsão de Born, e a força oriunda das funções químicas ácido e Base (AB) de Lewis.
APA, Harvard, Vancouver, ISO, and other styles
6

Gusmão, Paulo Tadeu Ribeiro de, and Adriana Pereira Pinto. "Avaliação da Filtração Direta Ascendente em Pedregulho para Tratamento das Águas da Barragem Duas Unas , na Região Metropolitana do Recife." Revista DAE 58, no. 183 (2010): 16–20. http://dx.doi.org/10.4322/dae.2014.050.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Silva, Felipe Amaral, Celimar Azambuja Teixeira, Karina Querne de Carvalho, and Fernando Hermes Passig. "Avaliação de um sistema composto por filtração ascendente e radiação ultravioleta no tratamento da água de chuva." Revista Ibero-Americana de Ciências Ambientais 9, no. 4 (May 23, 2018): 177–91. http://dx.doi.org/10.6008/cbpc2179-6858.2018.004.0015.

Full text
Abstract:
O objetivo deste trabalho foi o de caracterizar a qualidade da água de chuva após passar pelo sistema de filtração rápida seguido pela desinfecção por radiação ultravioleta, além de analisar a caracterização da qualidade da água de chuva após passar pelo telhado de fibrocimento e avaliar os possíveis usos da água de chuva, além de avaliar a eficiência do tratamento proposto. O sistema de tratamento consiste em um filtro de brita, areia e carvão seguido por um reator com lâmpadas germicidas para a desinfecção da água de chuva coletada. Os resultados obtidos mostram, que a qualidade água de chuva armazenada na cisterna 1 é comparável a corpos d’água de classe 1 segundo a Resolução 357/2005 do CONAMA e, portanto, um tratamento simplificado poderia ser aplicado para torná-la potável. De acordo com os parâmetros analisados, a qualidade da água de chuva após o tratamento proposto atendeu aos padrões exigidos pela ABNT NBR 15527:2007:2007 e USEPA (2012) para usos não potáveis e que os parâmetros analisados (pH, Temperatura, Cor, Turbidez, OD, DQO, NH­­­3, NO-2, NO3-, PO43-, SO42-, CT, CTer e EC) atendem aos padrões exigidos pela Portaria 2914/2011 do Ministério da Saúde para água potável. A água obtida após tratamento pode ser utilizada para fins não potáveis e em atividades de contato direto, tais como banho e lavagem de roupa e desta forma minimizando a demanda por água potável. Desta forma, não limitar o aproveitamento de água de chuva apenas para fins não nobres, como por exemplo, descarga de sanitários, irrigação de jardim e limpeza de calçadas.
APA, Harvard, Vancouver, ISO, and other styles
8

Hideo Fuji, Eduardo, Daniele Satie Koga, Yorgos Noleto Coutroutsos, and Emília Kiyomi Kuroda. "PÓS-TRATAMENTO DE LIXIVIADO DE ATERRO SANITÁRIO POR FILTRAÇÃO DIRETA ASCENDENTE EM PEDREGULHO." Periódico Eletrônico Fórum Ambiental da Alta Paulista 9, no. 11 (November 10, 2013). http://dx.doi.org/10.17271/198008279112013694.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Dissertations / Theses on the topic "Filtração Direta Ascendente"

1

Kuroda, Emília Kiyomi. "Avaliação da filtração direta ascendente em pedregulho como pré-tratamento em sistemas de dupla filtração." Universidade de São Paulo, 2002. http://www.teses.usp.br/teses/disponiveis/18/18138/tde-07012016-121656/.

Full text
Abstract:
Este trabalho consiste na avaliação do desempenho do sistema composto por filtração direta ascendente em pedregulho seguida de filtração rápida descendente. A investigação experimental foi realizada em instalação piloto, variando-se a taxa de filtração nos filtros ascendente (60 a 240 m3/m2.d) e descendente (100 a 240 m3/m2.d) com e sem execução de descargas de fundo intermediárias no ascendente. A água bruta foi proveniente de um manancial superficial com pH entre 6,5 a 7,5, valores de turbidez compreendidos entre 8,5 e 21 uT, cor verdadeira entre 19 e 50 unidades Hanzen e alcalinidade entre 6,7 e 10 mg CaCO3/L. Adicionalmente, verificou-se o comportamento da instalação, para uma condição simulada de ocorrência de pico de turbidez de 380 uT, com curta duração. Em função dos resultados obtidos foi possível realizar considerações com relação à ocorrência de desprendimento/carreamento contínuo de flocos no filtro ascendente e constatar as influências da execução de descargas de fundo intermediárias, com produção de efluentes de melhor qualidade e carreiras de filtração mais prolongadas. O filtro ascendente com taxa de filtração de 120 m3/m2.d, foi capaz de absorver o pico de turbidez de 380 uT, produzindo efluente pré-filtrado com valores de turbidez entre 0,3 e 5,7 uT, e o filtro descendente, com taxa de filtração de 180 m3/m2.d, produziu efluente final com valores consistentemente menores que 1 uT, e na maior parte do tempo menores que 0,1 uT.
This work consists of a performance evaluation of the system composed by direct upflow filtration in gravel followed by rapid downflow filtration in sand. The experimental investigation was accomplished in pilot installation, being varied the filtration rate in the upflow (60 to 240 m3/m2.d.) and downflow (100 to 240 m3/m2.d.) filters with and without execution of intermediate downflushes in the first one. The raw water was provided from a superficial source with pH between 6,5 to 7,5, turbidity values between 8,5 and 21 UT, visible colour between 19 and 50 uH and alkalinity between 6,7 and 10 mg CaC03/L. ln addition, the behavior of the installation was verified, for a simulate condition of turbidity peak occurrence of 380 uT, with short duration. From the obtained results it was possible to accomplish considerations concerning the detachment occurrence/continuous flowing of flakes in the upflow filter and to verify the influences of the execution of intermediate downflushes, with production of better quality effluents and longer filter runs. The upflow filter with filtration rate of 120 m3/m2.d. was able to attenuate the turbidity peak of 380 uT, producing prefiltered effluent with turbidity values between 0,3 and 5,7 uT, and the downflow filter, with filtration rate of 180 m3/m2.d. produced final effluent with consistently values lower than 1 uT and in most of time lower than 0,1 uT.
APA, Harvard, Vancouver, ISO, and other styles
2

Pereira, Pinto Adriana. "Utilização da filtração direta ascendente em pedregulho como alternativa de pré-filtração em sistemas de dupla filtração." Universidade Federal de Pernambuco, 2006. https://repositorio.ufpe.br/handle/123456789/5570.

Full text
Abstract:
Made available in DSpace on 2014-06-12T17:40:23Z (GMT). No. of bitstreams: 2 arquivo6180_1.pdf: 3188051 bytes, checksum: 2e41a037f926af5a1d1f2281898acade (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2006
Desempenho da filtração direta ascendente em pedregulho como alternativa de pré-filtração em sistema Dupla filtração. O presente trabalho foi desenvolvido em instalação piloto, de novembro de 2002 a julho de 2004, para avaliação do desempenho da filtração direta ascendente em pedregulho. Foi utilizada água de superfície da Barragem de Duas Unas com turbidez variando de apresentou turbidez entre 4,1 e 125 uT, predominando valores entre 4,1 e 30 uT, e cor aparente, foram registrados valores entre 17,5 e 550 uC, predominando valores entre 17,5 e 250 uC. O Sulfato de Alumínio Comercial líquido era adicionado à água de superfície em dosagens pré-definidas através dos ensaios de coagulação e filtração (ECF) realizados com o Filtro de Laboratório de Areia (FLA).Após essa mistura, a água coagulada era filtrada da em um filtro de fluxo ascendente e meio granular constituído por pedregulho de granulometria (2,4 mm a 50 mm). A dosagem era definida através Foram aplicadas dosagens entre 19,74 a 41,70 mg SA/L durante os ensaios efetivos. As taxas de filtração testadas durante os treze ensaios efetivos variaram de 45 a 195 m3/m2.dia. Durante os ensaios efetivos foram executadas descargas de fundo intermediarias na unidade de filtração, para verificação da sua eficiência na remoção das impurezas acumuladas nos interstícios granula e sua influência na duração da carreira de filtração
APA, Harvard, Vancouver, ISO, and other styles
3

Pereira, Pinto Adriana. "Utilização da filtração direta ascendente em pedregulho como alternativa de pré-filtração em sistemas de dupla filtração." Universidade Federal de Pernambuco, 2005. https://repositorio.ufpe.br/handle/123456789/5756.

Full text
Abstract:
Made available in DSpace on 2014-06-12T17:41:41Z (GMT). No. of bitstreams: 2 arquivo6490_1.pdf: 3188051 bytes, checksum: 2e41a037f926af5a1d1f2281898acade (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2005
Desempenho da filtração direta ascendente em pedregulho como alternativa de pré-filtração em sistema Dupla filtração. O presente trabalho foi desenvolvido em instalação piloto, de novembro de 2002 a julho de 2004, para avaliação do desempenho da filtração direta ascendente em pedregulho. Foi utilizada água de superfície da Barragem de Duas Unas com turbidez variando de apresentou turbidez entre 4,1 e 125 uT, predominando valores entre 4,1 e 30 uT, e cor aparente, foram registrados valores entre 17,5 e 550 uC, predominando valores entre 17,5 e 250 uC. O Sulfato de Alumínio Comercial líquido era adicionado à água de superfície em dosagens pré-definidas através dos ensaios de coagulação e filtração (ECF) realizados com o Filtro de Laboratório de Areia (FLA).Após essa mistura, a água coagulada era filtrada da em um filtro de fluxo ascendente e meio granular constituído por pedregulho de granulometria (2,4 mm a 50 mm). A dosagem era definida através Foram aplicadas dosagens entre 19,74 a 41,70 mg SA/L durante os ensaios efetivos. As taxas de filtração testadas durante os treze ensaios efetivos variaram de 45 a 195 m3/m2.dia. Durante os ensaios efetivos foram executadas descargas de fundo intermediarias na unidade de filtração, para verificação da sua eficiência na remoção das impurezas acumuladas nos interstícios granula e sua influência na duração da carreira de filtração
APA, Harvard, Vancouver, ISO, and other styles
4

Rohers, Fábio. "Tratamento físico-químico de lixiviado de aterro sanitário por filtração direta ascendente." Florianópolis, SC, 2007. http://repositorio.ufsc.br/xmlui/handle/123456789/90200.

Full text
Abstract:
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológco. Programa de Pos-Graduação em Engenharia Ambiental.
Made available in DSpace on 2012-10-23T07:08:17Z (GMT). No. of bitstreams: 1 248446.pdf: 3536538 bytes, checksum: b30f2bd885d9f4bffa45e3a3ea78beb4 (MD5)
A disposição dos resíduos sólidos tem sido um grande problema em virtude da preocupação crescente da preservação ambiental. A rápida industrialização e urbanização resultaram num incremento do consumo de produtos ou materiais diversos, conseqüentemente, aumentando a geração de resíduos sólidos, principalmente nas grandes cidades e regiões metropolitanas. Uma das alternativas mais utilizadas para dispor os resíduos sólidos são os aterros sanitários. Mas esta técnica requer cuidados na sua execução para que atenda às normas ambientais, como a impermeabilização da camada de base e a cobertura do aterro. Os lixiviados gerados pela degradação biológica dos resíduos contidos no seu interior e pela ação das chuvas que infiltram pelo mesmo podem contaminar os recursos hídricos. Os lixiviados caracterizam-se pela sua composição complexa e sua variabilidade em relação à quantidade e qualidade gerada. Sua composição e a concentração de substâncias poluidoras são influenciadas pelos tipos de resíduos depositados no aterro. Em geral os lixiviados, ou chorume como são comumente denominados, apresentam altas concentrações de contaminantes orgânicos representados pela demanda química de oxigênio (DQO) e demanda bioquímica de oxigênio (DBO), e também com altas concentrações de amônia. Diversos tratamentos são utilizados a fim de minimizar o impacto do lixiviado de aterros no meio ambiente. De forma básica os tratamentos se dividem em biológicos e físico-químicos, com maior ênfase no tratamento biológico. O lixiviado de lixo é um líquido com elevado potencial poluente, os métodos convencionais utilizados em seu tratamento têm descartado-o com intensa coloração e alta toxicidade. Este trabalho teve como objetivo implantar em escala piloto um sistema de filtração direta ascendente, para o tratamento do lixiviado "in natura", proveniente do aterro sanitário da cidade de Biguaçu - SC. O estudo foi desenvolvido em duas etapas utilizando cloreto férrico, sulfato de alumínio e sulfato ferroso como coagulantes principais, a primeira com o objetivo da otimização dos parâmetros operacionais através dos ensaios de bancada utilizando o equipamento Jar Test, a segunda etapa já com os parâmetros ótimos conhecidos (Gradientes de velocidade para a mistura rápida, tempo da mistura e dosagem de coagulante) partiu-se para os ensaios no piloto, como acompanhamento da eficiência do tratamento foram utilizadas rotinas analíticas para a determinação da sua eficiência. O filtro ascendente foi construído com tubos de PVC de 150 mm de diâmetro e 4,2 m de altura tendo como meio filtrante pedregulho e areia com diversas granulometrias. A taxa de filtração aplicada foi de 100 m3/m2.d. O tratamento do lixiviado por filtração direta ascendente teve redução significativa da maioria dos parâmetros analisados, destacando a redução de aproximadamente 90% de cor aparente, DQO 65%, DBO 45% e amônia 33%. The disposition of solid residues has been a great problem due to the growing preoccupation of environmental preservation. The quick industrialization and urbanization resulted in an increase of consumption of products or diverse materials, consequently increasing the generation of solid residues, especially in the large cities and metropolitan areas. One of the most used alternatives to dispose of solid residues is the sanitary landfill. However, this technique requires detailed care in its execution in order to attend environmental norms, such as the waterproofing of the base layer and the cover of the landfill. The leachates generated by biological degradation of the residues contained in the interior of the landfill and by action of rains that infiltrate it may contaminate water resources. Leachates are characterized by their complex composition and their variability related to the quantity and quality generated. Their composition and the concentration of polluting substances are influenced by the types of residues deposited in the landfill. Leachates or manure, as they are commonly denominated, present high concentrations of organic contaminants represented by the chemical demand of oxygen (CDO) and by the biochemical demand of oxygen (BDO), and also with high concentrations of ammonia. Several treatments are used in order to minimize the impact of leachates of landfills on the environment. They basically are divided in biological and physical-chemical, with a greater emphasis on biological treatment. The garbage leachate is a liquid with a high polluting potential, and the conventional methods used in its treatment have discarded it with intense coloration and high toxicity. This study had the objective to implant, on a pilot scale, a direct ascending filtration system for the treatment of "in natura" leachates coming from the sanitary landfill of the city of Biguaçú, SC. The study was developed in two phases using ferric chloride, aluminum sulphate and ferrous sulphate as the main coagulants, the first with the objective of optimizing the operational parameters through tests of bench using the Jar Test equipment, and the second phase, with the optimum parameters already known (Gradients of velocity for the fast mixture, time of mixture and dosage of coagulant), parted for the tests on the pilot, as a follow-up of the efficiency of the treatment analytical routines were used for the determination of its efficiency. The ascending filter was built with PVC tubes of 150 mm diameter and 4.2 meters of height, having as a filtration environment small rocks and sands of several granulometries. The rate of filtration applied was of de 100 m3/m2.d. The treatment of leachates by direct ascending filtration had a significant reduction of most of the parameters analyzed, point out to the reduction of approximately 90% of the apparent color, CDO 65%, BDO 45% and ammonia 33%.
APA, Harvard, Vancouver, ISO, and other styles
5

Paula, Donizeti de. "Avaliação da dupla filtração para tratamento de água superficial utilizando filtração ascendente em areia grossa." Universidade de São Paulo, 2003. http://www.teses.usp.br/teses/disponiveis/18/18138/tde-31102016-142553/.

Full text
Abstract:
Este trabalho consiste na avaliação do desempenho de uma instalação piloto de dupla filtração no tratamento de água superficial, apresentando turbidez entre 8,5 e 21 uT. A instalação piloto constituída de um sistema de filtração de duas fases, com filtração direta ascendente em areia grossa seguida da filtração rápida descendente em areia fina. A taxa de filtração variou de 120 a 360 m3/m2.dia no filtro ascendente e de 200 a 400 m3/m2.dia no filtro ascendente. Foram executadas descargas de fundo intermediários no filtro ascendente durante a carreira de filtração para avaliar a instalação piloto. Além disso, simulou pico de turbidez, para avaliar as condições. Baseado no trabalho experimental concluiu-se que: (i) a eficiência global do sistema de dupla filtração ascendente em areia grossa foi satisfatória, apresentando efluente final com turbidez inferior a 1 uT e cor verdadeira inferior a 1 uH; (ii) a distribuição da perda de carga nas camadas do meio granular do FAAG não apresentou diferenças significativas para as variadas taxas de filtração e modo de operação (com e sem execução de DIFs); (iii) os ensaios que foram realizados com a execução de DIFs apresentaram carreiras de filtração mais longas.
This work concerns the study of the performance of a double filtration pilot plant whom treating surface water, presenting turbidity between 8,5 and 21,0 NTU. The pilot plant consisted of a two-stage filtration system, with an upflow coarse sand direct filtrer followed by a dowflow fine sand filter. Filtration rats varied from 120 to 360 m/day in the upflow filter and from 200 to 400 m/day in the downflow filter. Intermediate downflow in the upflow filter were performed during the run length do evaluate the performance of the pilot plant in addition, a peak of turbidity in the for influent selected filter operating varabile, was studied here in. Based on the experimental work carried out, it was concluded that: (i) the global efficiency of the system of double filtration with upflow filtration in coarse sand was satisfactory, presenting final efflents with inferior turbidity to 1,0 NTU and inferior true color to 1 uH; (ii) the distribution of the load loss in the layers of the granular middle of FAAG didn\'t present significant differences for the varied filtration taxes and operation way (with and without execution of DFIs); (iii) the rehearsals that were accomplished with the execution of DFIs presented longer filtration runs.
APA, Harvard, Vancouver, ISO, and other styles
6

Gusmão, Paulo Tadeu Ribeiro de. "Utilização de filtração direta ascendente como pré-tratamento à filtração rápida descendente para tratamento de água para abastecimento." Universidade de São Paulo, 2001. http://www.teses.usp.br/teses/disponiveis/18/18138/tde-07012016-161754/.

Full text
Abstract:
Em instalação piloto, de 06/1998 a 10/1999, utilizando-se água natural de superfície com baixas turbidez e cor, foram avaliados dois sistemas de dupla filtração, com pré-tratamento em filtração direta ascendente em areia com taxas de 200 a 360 m3/m2.dia (sistema S01) e em filtração direta ascendente em pedregulho com taxas de 80 a 190 m3/m2.dia (sistema S02) e com tratamento final em filtração rápida descendente com taxas de 115 a 480 m3/m2.dia. As dosagens do coagulante (produto comercial de sulfato de alumínio) foram definidas utilizando-se filtro de laboratório de areia, havendo indicações de coagulação no mecanismo de adsorção, com neutralização parcial de carga. Foram executadas descargas de fundo intermediárias nas unidades de filtração direta ascendente, com significativa redução na perda de carga no meio granular de pedregulho. A turbidez, cor aparente, Fe e Mn totais dos efluentes finais dos sistemas atenderam às Normas Brasileiras para produção de água potável. No sistema S02 o crescimento da perda de carga no meio granular foi menos intenso na unidade de filtração direta ascendente do que no filtro rápido descendente, ocorrendo o inverso no sistema S01, no qual, em alguns ensaios, o filtro rápido descendente mostrou-se desnecessário. As carreiras de filtração foram de 27 a 88 h no sistema S01 e de 14 a 35 h no sistema S02. Em determinados casos, a floculação predominou na unidade de filtração direta ascendente em pedregulho, prejudicando a qualidade do seu efluente. O sistema S02 mostrou-se mais vantajoso que o sistema S01, exceto quando, neste, a filtração rápida descendente foi desnecessária.
Based on me investigation carried out in pilot plant, from June 1998 to October 1999, using natural surface raw water with low turbidity and color, two systems of two-stage filtration have been evaluated. As a pretreatment, the first system (S01) used direct up-flow sand filtration (with filtration rates from 200 to 360 m3/m2.day), and the second system (S02) used direct up-flow roughing filtration (with filtration rates from 80 to 190 m3/m2.day), both with final treatment based on rapid filtration (with filtration rates from 115 to 480 m3/m2.day) The coagulant doses (commercial product of aluminum sulfate) have been established through the use of laboratory scale sand filter, presenting signs of coagulation in the adsorption mechanism, with partial charge neutralization. Intermediate bottom discharges in the direct up-flow filtration units have resulted in significant reduction in thee headloss in gravel granular medium. The turbidity, apparent-color, total iron and manganese concentrations of the final effluents of the systems have attended the Brazilian Standards for drinking water production. The increase of headloss in gravel granular medium in system S02 was smaller in me direct up-fiow filtration unit than in the rapid filter, the opposite occurring in system S01, where some tests have proved lhe rapid filter redundant. The filter runs time were 27 to 88 hours in system S01 and 14 to 35 hours in system S02. In certain cases, flocculation was predominant in the direct up-flow roughing filtration unit, jeopardizing the effiuent quality. System S02 has proved advantageous in relation to system S01, except when in system S01 the rapid filter was redundant.
APA, Harvard, Vancouver, ISO, and other styles
7

Sá, Mirtys Arruda de. "Avaliação do desempenho de uma Estação de Tratamento de Água com sistema de filtração direta ascendente em escala real." Universidade Federal de Pernambuco, 2012. https://repositorio.ufpe.br/handle/123456789/10689.

Full text
Abstract:
Submitted by Eduarda Figueiredo (eduarda.ffigueiredo@ufpe.br) on 2015-03-05T14:05:01Z No. of bitstreams: 2 mas.pdf: 3892034 bytes, checksum: aa7e509a42d26e668bc737e3fdd940a6 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
Made available in DSpace on 2015-03-05T14:05:01Z (GMT). No. of bitstreams: 2 mas.pdf: 3892034 bytes, checksum: aa7e509a42d26e668bc737e3fdd940a6 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2012-03-29
O desempenho de uma Estação de Tratamento de Água (ETA) depende, inicialmente, de uma seleção adequada da tecnologia de tratamento e de um projeto criterioso, acompanhados da disponibilidade de recursos humanos e materiais que propiciem uma boa rotina de operação. Neste trabalho foi avaliado o desempenho da tecnologia da Filtração Direta Ascendente adotada em uma Estação de Tratamento de Água em escala real, nos anos I e III, uma vez que nesse ano a companhia de saneamento responsável por sua implantação e operação, em face do precário desempenho que vinha presentando, introduziu modificações de modo a transformá-la em ETA do tipo convencional (ou de ciclo completo). O trabalho foi estruturado nas seguintes etapas: (i) coleta de informações preliminares e caracterização das unidades componentes da ETA; (ii) acompanhamento e registro dos procedimentos operacionais; (iii) coleta e análise das resultados operacionais da própria estação, especialmente parâmetros físicoquímicos indicadores de qualidade da água; e (iv) avaliação conjunta dos resultados e dos procedimentos operacionais adotados. A conclusão do trabalho ressalta aspectos de suma importância: o conhecimento da variação da qualidade da água bruta no processo de seleção da tecnologia de tratamento a ser utilizada; a necessidade, óbvia, de se implantar uma ETA em conformidade com o seu projeto executivo; a execução de procedimentos operacionais adequados; e a necessidade de correto e permanente controle operacional em todas as etapas do processo de tratamento.
APA, Harvard, Vancouver, ISO, and other styles
8

Nascimento, Marcely Ferreira. "Remoção de oocistos de Cryptosporidium por meio da filtração direta ascendente em areia : avaliação em escala piloto." reponame:Repositório Institucional da UnB, 2009. http://repositorio.unb.br/handle/10482/8991.

Full text
Abstract:
Dissertação (Mestrado em Tecnologia Ambiental e Recursos Hídricos)-Universidade de Brasília, Brasília, 2009.
Submitted by Luiza Moreira Camargo (luizaamc@gmail.com) on 2011-07-05T16:33:30Z No. of bitstreams: 1 2009_MarcelyFerreiraNascimento.pdf: 4078879 bytes, checksum: c6e557f5165ad0b2f47fa09946ad8df4 (MD5)
Approved for entry into archive by Jaqueline Ferreira de Souza(jaquefs.braz@gmail.com) on 2011-07-08T14:41:28Z (GMT) No. of bitstreams: 1 2009_MarcelyFerreiraNascimento.pdf: 4078879 bytes, checksum: c6e557f5165ad0b2f47fa09946ad8df4 (MD5)
Made available in DSpace on 2011-07-08T14:41:28Z (GMT). No. of bitstreams: 1 2009_MarcelyFerreiraNascimento.pdf: 4078879 bytes, checksum: c6e557f5165ad0b2f47fa09946ad8df4 (MD5)
Dentre as doenças de veiculação hídrica que vêm recebendo maior atenção nos últimos anos, destaca-se a Criptosporidiose que é causada pelo protozoário Cryptosporidium. Os oocistos de Cryptosporidium são resistentes ao estresse ambiental e à inativação por cloro e, devido ao seu tamanho, têm facilidade para passar através do processo de tratamento físico de água. Nesse contexto, o presente trabalho teve como objetivo avaliar a remoção de oocistos de Cryptosporidium parvum por meio da filtração direta ascendente em areia. Os experimentos de filtração direta ascendente, em escala piloto, foram realizados com água proveniente do Lago Paranoá inoculada com oocistos de Cryptosporidium parvum de modo a se obter concentração da ordem de 103 ooc./L na água de estudo. A taxa de filtração adotada foi de 120m³/m².d. Em nove experimentos de filtração a água de estudo apresentava valores baixos de turbidez (2,7 a 4,8 UT) e em três experimentos a turbidez era de cerca de 30 UT. Os resultados revelaram que a eficiência de remoção de oocistos de Cryptosporidium parvum no início do experimento de filtração foi, em média, 0,5 log menor que no período de funcionamento estável, em que a remoção média de oocistos de Cryptosporidium parvum foi de 3,5 log. Os valores de turbidez na água filtrada foram inferiores ao limite de 0,5 UT recomendado na legislação brasileira, Portaria MS No. 518/2004, e também inferiores ao limite da legislação americana (0,3 UT), exceto nos experimentos com turbidez mais elevada. A concentração de oocistos de Cryptosporidium parvum na água de lavagem do filtro confirmou o elevado risco de contaminação microbiológica desse resíduo. O tratamento estatístico dos dados indicou que na água filtrada não houve correlação significativa entre a concentração de oocistos de Cryptosporidium parvum e os parâmetros turbidez, coliformes totais e E.coli. Correlação fraca foi observada entre oocistos de Cryptosporidium parvum e contagem de partículas nas faixas de tamanho do oocisto de Cryptosporidium. Os resultados revelam que os filtros rápidos ascendentes apresentam eficiências de remoção de oocistos de Cryptosporidium parvum similares aos filtros rápidos descendentes. _______________________________________________________________________________ ABSTRACT
Among the waterborne diseases that have received increased attention in recent years stands out Cryptosporidiosis, which is caused by the parasite protozoan Cryptosporidium. Cryptosporidium oocysts are resistant to environmental stress and inactivation by chlorine and, due to their size,, may pass through the physical treatment processes of water. In this context, this study aimed to evaluate the removal of Cryptosporidium oocysts by up flow direct sand filtration. The experiments in pilot scale were carried out with Paranoá lake water spiked with Cryptosporidium parvum oocysts in order to obtain concentration of about 103 ooc./L in the study water. The filtration rate adopted was 120m³/m².d. In nine experiments the study water presented low levels of turbidity (2.7 to 4.8 NTU) and in three experiments the turbidity was of around 30 NTU. The results showed that the removal efficiency of Cryptosporidium parvum oocysts in the early stages of the filtration experiments was, in average 0.5 log lower than during filtration steady state where the average removal of Cryptosporidium parvum oocysts was 3.5 log. The values of turbidity in filtered water were below the limit of 0.5 NTU recommended by UT Brazilian Health Authority, Decree MS No. 518/2004, and also below the limit set by U.S. legislation (0.3 NTU), except in experiments with study water with higher turbidity. The concentration of Cryptosporidium parvum oocysts in the filter backwash water confirmed the high risk of microbiological contamination of the this waste. Statistical analysis indicated that there was no significant correlation between the concentration of Cryptosporidium parvum oocysts and characteristics such as turbidity, total coliform and E.coli in the filtered water. Weak correlation was found between Cryptosporidium parvum oocysts and particle counting in size range of Cryptosporidium oocyst. The results suggest that up flow direct filtration has similar removal efficiency of Cryptosporidium oocysts when compared with down flow filtration.
APA, Harvard, Vancouver, ISO, and other styles
9

Fujii, Eduardo Hideo. "Avaliação da aplicabilidade da filtração direta ascendente em pedregulho como pós-tratamento de lixiviado de aterro sanitário." Universidade Estadual de Londrina. Centro de Tecnologia e Urbanismo. Programa de Pós-Graduação em Engenharia de Edificações e Saneamento, 2014. http://www.bibliotecadigital.uel.br/document/?code=vtls000190019.

Full text
Abstract:
Atualmente, o método de disposição final de resíduos sólidos em aterro sanitário tem sido o mais aceito e empregado em países desenvolvidos ou subdesenvolvidos com uso de grande área territorial. Apesar das vantagens deste método, os resíduos sólidos depositados sofrem decomposições físicas, químicas e biológicas e são solubilizados na água, gerando produção de gás metano e de um líquido de coloração escura e altamente poluidor denominado chorume ou percolado/lixiviado de aterro sanitário. Este líquido apresenta composição variável e complexa e pode ter elevadas concentrações de nitrogênio amoniacal, matéria orgânica biodegradável e recalcitrante. Assim, faz-se necessário o seu pós-tratamento para remover a matéria orgânica recalcitrante, atendendo aos padrões físicos, químicos e biológicos de lançamento de efluente das legislações. Este trabalho avaliou a aplicabilidade do pós-tratamento por filtração direta ascendente em pedregulho - FDAP em lixiviado tratado previamente por stripping de amônia seguido de tratamento biológico por lodos ativados. Os ensaios na instalação piloto de FDAP foram realizados visando obter a melhor condição de eficiência e operação através de modificações da camada filtrante, variações na dosagem de coagulante e na taxa de filtração. Os parâmetros monitorados para avaliar a eficiência do pós-tratamento foram cor aparente, cor verdadeira, demanda química de oxigênio (DQO) e carbono orgânico total (COT). Os parâmetros típicos de concepção e de controle operacional foram: camada filtrante composta por pedregulho e areia, 3 descargas de fundo intermediárias, perda de carga limite de 120 cm, duração da carreira de filtração mínima de 24 horas, taxa de filtração de 15 m3 m2 dia-1, dosagem de 400 mg L-1 de Fe e pH 4,0. O sistema de filtração direta ascendente em pedregulho mostrou ser uma técnica aplicável para o pós-tratamento de lixiviado, com remoções variando de 96,0 a 99,7% para cor aparente, com residuais de 170 a 13 uH, respectivamente, de 99,4% para a cor verdadeira (com valor máximo de 24 uH), 81,8% para a DQO (com valor máximo de 200 mg L-1), 95,2% para o COT (com valor de 44 mg L-1) e carreira de filtração com duração de 37,1 h.
The current final disposal method of solid waste in landfills has been the most accepted and used in developed and developing countries with large territorial area. Despite the advantages of this method, the solid waste deposited undergo physical, chemical and biological decomposition and are solubilized in water, producing methane gas and a dark and highly pollutant liquid called landfill leachate. The landfill leachate has a complex and variable composition, and can have high concentrations of ammoniacal nitrogen, biodegradable and recalcitrant organic matter. Thus, it is necessary a post-treatment of landfill leachate to remove its recalcitrant organic matter and to reach the physical, chemical and biological standards for this effluent discharge by current regulations. This study evaluated the applicability of post-treatment by up-flow direct filtration in gravel - FDAP for leachate pretreated by ammonia stripping followed by biological treatment with activated sludge. The assays on the FDAP pilot plant were conducted to obtain the best condition and operating efficiency through modifications of the filter bed, variations on dosage of coagulant and filtration rate. Parameters monitored to evaluate treatment effectiveness were apparent color, true color, chemical oxygen demand (COD) and total organic carbon (TOC). Typical and operational control parameters were: filter bed composed of gravel and sand, 3 intermediate downflushes, head loss limited to 120 cm, minimum operation time of 24 h, filtration rate of 15 m3 m2 day-1, coagulant dosage of 400 mg L-1 Fe and pH 4,0. The results showed that the up-flow direct filtration in gravel system presented to be an applicable technical for post-treatment of leachate, removing apparent color from 96,0 to 99,7%, with residual of 170 to 13 uH, respectively, 99,4% of true color (with maximum value of 24 uH), 81,8% of COD (with a maximum value of 200 mg L-1), 95,2% of TOC (with value of 44 mg L-1), during 37,1 h of filtration.
APA, Harvard, Vancouver, ISO, and other styles
10

Benini, Bianca Dieile da Silva. "Remoção de substâncias húmicas na dupla filtração com filtro ascendente de pedregulho." Universidade de São Paulo, 2003. http://www.teses.usp.br/teses/disponiveis/18/18138/tde-11102016-164520/.

Full text
Abstract:
Este trabalho foi realizado com o objetivo de avaliar o comportamento de um sistema de dupla filtração, utilizando filtro ascendente de pedregulho seguido de filtro rápido descendente na remoção de substâncias húmicas. A parte experimental foi realizada em uma instalação piloto, que utilizou como afluente a água do Ribeirão Feijão na qual foi adicionado extrato de substâncias húmicas, previamente extraído de solo turfoso por meio de extração alcalina, para que a cor verdadeira da água de estudo resultasse entre 90 e 110 uH. As condições de coagulação, como gradiente de velocidade, dosagem e pH, foram definidos em ensaios com jarteste. As taxas utilizadas no filtro ascendente em pedregulho foram de 80 e 120 m3/m2.dia e no sistema de filtração rápida descendente de 80, 120, 150, 180, 220 e 240 m3/m2.dia. As carreiras tiveram duração máxima de 72 horas. A utilização do critério de realização de Descargas de Fundos Intermediárias (DFIs), quando o efluente do Filtro Ascendente de Pedregulho (FAP) atingisse valor maior ou igual 50 uH, não permitiu aumento da cor no efluente final. O sistema de dupla filtração estudado foi eficiente na remoção de cor, atingindo diversas vezes remoção completa; outros parâmetros relativos à concentração de substâncias húmicas, como absorvância (254 nm) e Carbono Orgânico Dissolvido (COD), foram removidos entre 89,1 a 93,6% e 27,5 a 48,5% respectivamente.
The present work was carried out to evaluate the removal of humic substances in a double filtration system, comprising on upflow gravel prefilter followed by a rapid down flow filter. Raw water was abstracted from the influent took to the municipal water treatment Plant 2. Humic substances were extracted from peat through alkaline process. The concentrated solution was pumped to raw water in order to obtain true colour of 90-110 Hu in the influent to the pilot plant. Filtration rates studied were as follows: 80 and 120 m3/m2.day in the upflow filter 80, 120, 150, 180, 220 e 240 m3/m2.day in the down flow filter. Maximum filter run length was fixed in 72 hours. Intermediate down flushes in the upflow filter were performed during the run when the effluent colour reached 50 Hu. It is concluded that the system performed efficiently to remove colour; in most part of the effluent colour remained bellow 1 Hu. Absorbance (254 nm) removal resulted high (between 89,1% and 93,6%). Dissolved organic carbon resulted satisfactory (27,5% to 48,5%).
APA, Harvard, Vancouver, ISO, and other styles
More sources
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography