Contents
Academic literature on the topic 'Fixação interna de fraturas/métodos'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Fixação interna de fraturas/métodos.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Journal articles on the topic "Fixação interna de fraturas/métodos"
Cueva, Luis Orlando Baselly, Sheila Canevese Rahal, Luciane Reis Mesquita, Maria Jaqueline Mamprim, Arthur Carlos da Trindade Alves, Washington Takashi Kano, Túlio Genari Filho, and Lídia Mitsuko Matsubara. "Considerações sobre fraturas em aves." Veterinária e Zootecnia 27 (March 12, 2020): 1–11. http://dx.doi.org/10.35172/rvz.2020.v27.351.
Full textMonteiro, Gustavo Cará, Benno Ejnisman, Carlos Vicente Andreoli, Alberto de Castro Pochini, and Edgler Olympio. "Resultados do tratamento das fraturas do terço proximal do úmero com placas de bloqueio." Acta Ortopédica Brasileira 19, no. 2 (April 2011): 69–73. http://dx.doi.org/10.1590/s1413-78522011000200001.
Full textOzturk, Hayati, and Kenan Kaygusuz. "Novo Parafuso (Acutrak®) No tratamento cirúrgico de jogadores de futebol de elite com fraturas do quinto metatarso." Acta Ortopédica Brasileira 17, no. 5 (2009): 262–64. http://dx.doi.org/10.1590/s1413-78522009000500001.
Full textCesconetto, Lorenzzo de Angeli, André Vítor Alves Araújo, Antonio Dionizio Albuquerque Neto, Daniel Assunção Cerqueira, and Antonio Augusto Campanha. "Tratamento de fratura bilateral de mandíbula atrófica severamente deslocada." Journal of the Brazilian College of Oral and Maxillofacial Surgery 5, no. 1 (March 25, 2019): 53–57. http://dx.doi.org/10.14436/2358-2782.5.1.053-057.oar.
Full textDallabrida, Ademar Luiz, João Eduardo Schossler, Eduardo Santiago Ventura de Aguiar, Gustavo Frassetto Amendola, José Henrique Souza da Silva, and José Mario Doleys Soares. "Análise biomecânica ex vivo de dois métodos de osteossíntese de fratura diafisária transversal em fêmur de cães." Ciência Rural 35, no. 1 (February 2005): 116–20. http://dx.doi.org/10.1590/s0103-84782005000100018.
Full textYang, Yunfeng, Jiaqian Zhou, Bing Li, Hongmou Zhao, Tao Yu, and Guangrong Yu. "Exploração operatória e redução de sindesmose em lesão de tornozelo de Weber tipo C." Acta Ortopédica Brasileira 21, no. 2 (April 2013): 103–8. http://dx.doi.org/10.1590/s1413-78522013000200007.
Full textHu, Sun-Jun, Shi-Min Zhang, and Guang-Rong Yu. "Tratamento das fraturas femorais subtrocantéricas com placas de bloqueio lateral da parte proximal do fêmur." Acta Ortopédica Brasileira 20, no. 6 (December 2012): 329–33. http://dx.doi.org/10.1590/s1413-78522012000600003.
Full textCâmara, Antônio Carlos Lopes, Eraldo Barbosa Calado, João Marcelo A. de Paula Antunes, Camila Marinho de M. Oliveira, José Augusto Bastos Afonso, and Nivaldo de Azevêdo Costa. "Tratamento conservativo e cirúrgico em 22 ruminantes com fraturas em membros." Pesquisa Veterinária Brasileira 34, no. 11 (November 2014): 1045–50. http://dx.doi.org/10.1590/s0100-736x2014001100001.
Full textMontovani, Jair Cortez, Emanuel Araújo Nogueira, Fabricio Dominici Ferreira, Arlindo Cardoso Lima Neto, and Victor Nakajima. "Cirurgia das fraturas do seio frontal: estudo epidemiológico e análise de técnicas." Revista Brasileira de Otorrinolaringologia 72, no. 2 (April 2006): 204–9. http://dx.doi.org/10.1590/s0034-72992006000200009.
Full textYu, Guangrong, Kai Chen, and Tao Yu. "Desenho de placa em forma de borboleta para tratamento de fraturas do calcâneo." Acta Ortopédica Brasileira 20, no. 6 (December 2012): 324–28. http://dx.doi.org/10.1590/s1413-78522012000600002.
Full textDissertations / Theses on the topic "Fixação interna de fraturas/métodos"
Fernandes, Itana Santos. "Análise mecânica e fotoelástica de diferentes métodos de fixação mandibular na região do forame mentual." Escola de Medicina e Saúde Pública, 2013. http://www7.bahiana.edu.br//jspui/handle/bahiana/92.
Full textMade available in DSpace on 2015-04-15T02:15:48Z (GMT). No. of bitstreams: 1 Itana Santos Fernandes.pdf: 716606 bytes, checksum: bfc40cd2b0d01dcd144f4f7220ea267e (MD5) Previous issue date: 2013
O tratamento de fraturas de mandíbula na região de sínfise e parassínfise com uso de miniplacas e parafusos é especialmente problemático devido às forças de torção presentes nestas áreas. Os primeiros estudos a cerca do tema sugerem o uso de duas miniplacas do sistema 2,0mm fixadas acima e abaixo do forame mentual, com parafusos monocorticias, para neutralizar as cargas funcionais. Com a melhoria das ligas metálicas e o desenvolvimento de novos tipos de dispositivos de fixação, é possível sugerir que a utilização de uma única placa na zona de tensão da mandíbula seja suficiente para estabilizar a fratura durante o período de reparo ósseo. O objetivo deste trabalho foi revisar a literatura sobre as técnicas de fixação interna de fraturas de parassínfise mandibular ressaltando a possibilidade de alteração de técnica para a diminuição do número de placas para a estabilização das fraturas.
Lyrio, Mariana Camilo Negreiros 1980. "Comparação entre métodos de fixação interna utilizadas no tratamento de fraturas do ângulo mandibular = estudo mecânico." [s.n.], 2011. http://repositorio.unicamp.br/jspui/handle/REPOSIP/290202.
Full textTese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-18T20:34:21Z (GMT). No. of bitstreams: 1 Lyrio_MarianaCamiloNegreiros_D.pdf: 27352279 bytes, checksum: c9fcc8fa65410e2e71a94c3f054de2c6 (MD5) Previous issue date: 2011
Resumo: Apesar dos diversos tipos de fixação interna existentes ainda não há um consenso quanto ao método de imobilização das fraturas do ângulo mandibular. Além disso, são poucos os estudos sobre a utilização de placas grade ultimamente lançadas no mercado. O presente estudo visou avaliar comparativamente a resistência entre três tipos de fixação interna em réplicas de hemimandíbulas de poliuretano seccionadas na região de ângulo mandibular, simulando uma fratura linear. As formas de fixação incluíram a utilização de placas em forma de grade com e sem barra intermediária e o método descrito por Champy (1978). O objetivo foi definir por meio de análise mecânica a técnica que permitiu maior resistência na fixação deste tipo de fratura. Os testes de carregamento linear vertical foram realizados em amostras de cada grupo estudado (n = 10) utilizando uma unidade de testes mecânicos para registro da carga atingida, nos momentos que o deslocamento vertical alcançou 3 mm e 5 mm. Médias e desvio padrão foram avaliados aplicando-se a Análise de Variância e o teste de Duncan em nível de significância de 5%. Concluiu-se que a técnica de fixação interna para as fraturas de ângulo mandibular descrita por Champy (1976) foi a mais resistente e, que a inclusão de barra vertical intermediária nas placas grade não ofereceu aumento da resistência quando comparadas às placas grade sem barra
Abstract: Although there are several methods of stable fixation, there is no consensus about the treatment of mandibular angle fractures, Also, there are few studies about grid plates recently commercially available. This study compares the resistance of three fixation methods in polyurethane hemimandible replicas. Those were osteotomized at the angle region to simulate a linear fracture. Fixation methods were four-hole 2.0mm grid plates with and without a vertical intermediate bar and 2.0mm four-hole straight plate. The objective was to determine, through mechanical analysis, the fixation method that results in greater resistance to displacement. The hemimandibles were submitted to vertical linear loading in a mechanical test unit for registration of load after displacement of 3 and 5mm. Means and standard deviation were determined. Variance analysis and Ducan's test were applied considering a significance level of 5%. Results showed that the 2.0 four-hole plates, positioned according to the Champy technique, provide greater stability than the grid plates. When a vertical intermediate bar was added to the grid plates, resistance of the system was not increased
Doutorado
Cirurgia e Traumatologia Buco-Maxilo-Faciais
Doutor em Clínica Odontológica
Raduan, Neto Jorge [UNIFESP]. "Tratamento das fraturas redutíveis e instáveis da extremidade distal do rádio - ensaio clínico randomizado comparativo dos métodos de fixação com placa volar bloqueada e com fixador externo." Universidade Federal de São Paulo (UNIFESP), 2015. http://repositorio.unifesp.br/handle/11600/39302.
Full textApproved for entry into archive by Diogo Misoguti (diogo.misoguti@gmail.com) on 2016-06-24T15:01:31Z (GMT) No. of bitstreams: 1 2015-12-doutorado-jorge-raduan-neto.pdf: 3009058 bytes, checksum: f417f06d1422ff0ff7fb5ef2c88c34c8 (MD5)
Made available in DSpace on 2016-06-24T15:01:31Z (GMT). No. of bitstreams: 1 2015-12-doutorado-jorge-raduan-neto.pdf: 3009058 bytes, checksum: f417f06d1422ff0ff7fb5ef2c88c34c8 (MD5) Previous issue date: 2015
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Introdução: No tratamento das fraturas instáveis da extremidade distal do rádio não há evidência conclusiva quanto à maior efetividade de um dos métodos de redução e fixação: incruenta com fixador externo (FE) ou aberta com placa volar bloqueada (PVB). Objetivo: O objetivo é determinar qual dos dois métodos é mais efetivo. Métodos: Oitenta pacientes foram incluídos neste ensaio clínico randomizado. O desfecho primário foi o questionário Disabilities of the Arm, Shoulder and Hand (DASH) e a mensuração da dor (EVA). A avaliação final deu-se com 12 meses de pós-operatório. Resultados: Na avaliação final não houve diferença entre os grupos nas avaliações do questionário DASH (3,71 para o grupo PVB e 2,72 para o grupo FE, p=0,58), e da dor pela EVA (0,84 para o grupo PVB e 0,53 para o grupo FE, p=0,39). O tratamento com PVB foi mais efetivo que aquele com FE na avaliação precoce com oito semanas para questionário DASH (21,82 para o grupo PVB e 39,88 para o grupo FE, p=0,0012). No grupo tratado com PVB, houve 11,7% de complicações e, no grupo tratado com fixador externo, 26,3%. Houve três falhas de tratamento no grupo tratado com PVB e nenhuma no outro grupo. Conclusão: Não se aferiram diferenças entre os grupos nas avaliações finais do questionário DASH e da dor pela EVA. Na avalição precoce com oito semanas, houve diferença favorável ao método de PVB.
Introduction: In the treatment of unstable fractures of the distal radius there is no conclusive evidence about the greater effectiveness of the reduction and fixation methods: bloodless external fixation (BEF) or open locked volar plate (LVP). The goal is to determine which of the two methods is most effective. Methods: Eighty patients were enrolled in this randomized clinical trial. The primary endpoint was the DASH questionnaire and measurement of pain (VAS). The final assessment was given at 12 months postoperatively. Results: In the final evaluation there was no difference between groups in assessments of the DASH questionnaire (3.71 for the LVP group and 2.72 for the BEF group, p = 0.58), and pain by VAS (0,84 to LVP group and 0.53 for the BEF group, p = 0.39). Treatment with LVP was more effective than one with BEF in early evaluation with eight weeks to DASH questionnaire (21.82 for the LVP group and 39.88 for the BEF group, p = 0.0012). In the group treated with LVP, there were 11.7% of complications and, in the group treated with external fixator, 26.3%. There were three treatment failures in the group treated with LVP and none in the other group. Conclusions: There were not assessed differences between groups in the final evaluations of the DASH questionnaire and the pain by VAS. In the early eight week assessment, there was positive difference to the LVP method.
FAPESP: 2012/00806-2
Jesus, Giorge Pessoa de [UNESP]. "Avaliação do comportamento mecânico de três diferentes tipos de osteossíntese em fratura de côndilo mandibular: análise por elementos finitos 3D." Universidade Estadual Paulista (UNESP), 2013. http://hdl.handle.net/11449/110827.
Full textO uso de duas miniplacas retas é o método mais indicado na literatura, para se prevenir complicações no tratamento de fraturas de côndilo. Diferentes estudos evidenciam que a estabilidade da osteossíntese é relacionada com as tensões mecânicas que ocorrem na região do côndilo, geradas pelos músculos da mastigação. O objetivo neste estudo foi avaliar o comportamento mecânico de três métodos de osteossíntese, por meio de um modelo mandibular de elementos finitos (MEF), comparando a distribuição de tensões e o comportamento dos materiais nas fraturas subcondilares baixas. Simulou-se uma fratura transversa subcondilar baixa, no modelo mandibular e a adaptação dos materiais de osteossíntese para a fixação da fratura. Três métodos de fixação com placas de titânio foram testados: 1) duas placas retas; 2) uma placa lambda e 3) uma placa trapezoidal. Os resultados mostraram que os métodos de osteossíntese proporcionam uma boa rigidez ao sistema de fixação, com pouco deslocamento na linha de fratura. Apesar disto, com a intensidade da força aplicada, todos os modelos estariam sujeitos a falhas, pois apresentaram valores de tensão de von Mises muito elevados. Comparando o desempenho dos três modelos de placas testados, observou-se que, a placa lambda se comportou melhor, havendo uma distribuição das tensões de von Mises sobre o material de fixação e tensão máxima principal sobre o osso mais homogênea.
The use of two straight plates is the most indicated in literature, to prevent the subcondilar fractures complications. Different studies have highlighted that the osteosynthesis stability is related to the mechanical stresses that occur in the region of the condyle, generated by the chewing muscles. This study evaluated the biomechanical behavior of three methods of fixation, through a mandibular finite element model (FEM), comparing the stress distribution and behavior of materials in low subcondilar fractures. A transverse fracture was simulated in the mandibular model and on adapting osteosynthesis materials for fracture fixation. Three methods of fixations using titanium plates were tested: two straight plates; one lambda plate and; one trapezoidal plate. The results showed that the method of osteosynthesis provides a good stiffness on the fixation system with little displacement at the fracture line. Nevertheless, by the intensity of the applied force, all models would be subject to failure, because they presented very high stress values. Comparing the performance of the three plate’s models tested, it was observed better behaviors for the lambda plate, with a more homogeneous distribution of von Mises stresses on the osteosynthesis devices and maximum principal strain over the bone.
Bastos, Endrigo Oliveira. "Avaliação do tratamento cirúrgico das fraturas de côndilo mandibular pelo acesso retromandibular transparotídeo." Universidade de São Paulo, 2010. http://www.teses.usp.br/teses/disponiveis/5/5158/tde-21122010-120024/.
Full textINTRODUCTION: Open reduction and rigid internal fixation through retromandibular transparotid approach has been increasingly accepted as one of the options for treatment of fractures of the mandibular condyle, which is still a controversial subject. OBJECTIVES: To evaluate surgical treatment through retromandibular transparotid approach for extracapsular fractures of mandibular condyle in adults. METHODS: Ten consecutive patients operated on by the author at University of São Paulo Medical School Hospital were retrospectively evaluated. All of them were adults with extracapsular fractures of mandibular condyle causing shortening greater than 2 mm or deviation greater than 10 degrees. Patients were operated through retromandibular transparotid approach and had their pre and postoperative CT scans assessed with tridimensional reconstruction. Quality of reduction at fracture site was classified as optimal, satisfactory or poor. In seven patients with unilateral fractures, non-fractured sides served as controls in quantitative assessment condylar head positioning. Variables condylar height and sagittal, axial and coronal inclinations were measured in preoperative and postoperative CT scans, on fractured and not fractured sides. The different measures were compared. On morbidity of the approach, were evaluated: facial animation asymmetry, incidence of salivary fistula or infection and quality of scar. At least 18 months after surgery, patients were called for an assessment of postoperative period. They were asked about the presence of clicking joints, limitation on mouth opening, facial pain and poor mastication. Situation at postoperative period was compared with the one previous to trauma. Patients were examined for clicking or pain on palpation, uncorrected intercuspation, chin deviation on mouth opening and limitation on protrusion or laterality. The maximum mouth opening was measured. RESULTS: At the fracture site, reduction was rated as satisfactory or ideal in nine patients. As for the positioning of the condylar head, for the variables height and coronal condylar inclination, preoperatively, there was statistical difference between fractured and normal sides. Postoperatively, there was no difference for any variable when comparing fractured and normal sides. There were no asymmetries in facial animation, salivary fistula or infection since immediate postoperative period. One patient had hypertrophic scar. In the late postoperative period, were found: maximum mouth opening between 39 and 55 mm, chin deviation at oral opening in one patient and the emergence of clicking in two, data that was not statistically different from the period before the trauma. CONCLUSIONS: Treatment of shortened or deviated extracapsular fractures of the mandibular condyle in adults by open reduction and rigid internal fixation through retromandibular transparotid approach can provide correction of condylar anatomy with low morbidity and satisfactory functional outcome
Guastaldi, Fernando Pozzi Semeghini [UNESP]. "Caracterização físico-química, morfológica, análise mecânica e de elementos finitos 3D, de diferentes placas e parafusos metálicos e técnicas de fixação interna, empregadas em fraturas de ângulo mandibular." Universidade Estadual Paulista (UNESP), 2013. http://hdl.handle.net/11449/101067.
Full textProposição: Realizar uma caracterização físico-química, morfológica e comparar o comportamento mecânico de uma liga experimental de Ti-Mo, ao sistema de fixação análogo à base de Ti, em fraturas de ângulo mandibular, favoráveis ao deslocamento. Adicionalmente, análises de elementos finitos 3D foram realizadas para avaliar o padrão de distribuição de tensões nas placas e nos parafusos. Material e Método: Vinte e oito réplicas de mandίbulas de poliuretano foram usadas e uniformemente seccionadas na região do ângulo mandibular esquerdo. Estas foram divididas em 4 grupos considerando o material das placas e as técnicas de fixação interna: grupo Eng 1P, uma placa (zona de tensão da mandίbula) e 4 parafusos de 6 mm de comprimento; grupo Eng 2P, duas placas (uma na zona de tensão da mandίbula e a outra na zona de compressão), a primeira fixada com 4 parafusos de 6 mm de comprimento e a segunda com 4 parafusos de 12 mm de comprimento, sendo todo o material de fixação do sistema 2.0-mm. Os mesmos grupos foram criados para a liga Ti-15Mo. Cada grupo foi submetido a uma carga vertical linear no primeiro molar. As médias e os desvios-padrão foram comparados para avaliação estatίstica (ANOVA; p < .05). Adicionalmente, foi construído um modelo de elementos finitos 3D considerando as mesmas variáveis para avaliar as tensões equivalentes de von Mises (σvM) nas placas e nos parafusos. Resultados: Diferença estatisticamente significativa (p < .05) foi encontrada quando foi realizada a comparação entre ambas as técnicas de fixação (1 e 2 placas), independentemente do material das placas (cpTi and Ti-15Mo). Quando considerado os valores das tensões equivalentes de von Mises (σvM) para...
Purpose: Perform a physico-chemical and morphological characterization and compare the mechanical behavior of an experimental Ti-Mo alloy to the analogous metallic Ti-based fixation system, for mandibular angle fractures, favorable to displacement. Additionally, finite element analysis was performed to assess the stress distribution in the plates and screws. Material and Method: Twenty eight polyurethane mandible replicas were used and uniformly sectioned on the left mandibular angle. These were divided into 4 groups considering the material of the plates and the internal fixation techniques: group Eng 1P, one 2.0-mm plate (tension zone of the mandible) and 4 screws 6 mm long; group Eng 2P, two 2.0-mm plates (one in the tension zone of the mandible and the other in the compression zone), the first fixed with 4 screws 6 mm long and the second with 4 screws 12 mm long. The same groups were created for the titanium alloy (Ti-15Mo). Each group was subjected to linear vertical loading at the first molar. Means and standard deviations were compared with respect to statistical significance (ANOVA; p < .05). Additionally, an three-dimensional finite element model reproducing the characteristics of the specimens used in the mechanical tests were created to evaluate the von Mises equivalent stress (σvM) in the plates and screws. Results: Statistically significant difference (p < .05) was found when the comparison between both internal fixation techniques (1 and 2 plates) was performed, regardless the materials of the plates (cpTi and Ti-15Mo). When considering the von Mises equivalent stress (σvM) values for the comparison between both groups (Eng and Ti-15Mo) with 1 plate, an decrease of 10.5% in the plate and an decrease of 29.0% in the screws... (Complete abstract click electronic access below)
Gracitelli, Mauro Emilio Conforto. "Estudo randomizado da osteossíntese das fraturas da extremidade proximal do úmero com placa ou haste intramedular." Universidade de São Paulo, 2015. http://www.teses.usp.br/teses/disponiveis/5/5140/tde-24022016-091653/.
Full textINTRODUCTION: Fractures of the proximal humerus are common, with an increasing incidence in the elderly and with a high impact on quality of life and shoulder function. For displaced fractures, the locking plate is the most used method of osteosynthesis. Studies have shown good clinical results with the use of locking plates, but also with the fixation with locking intramedullary nail. The aim of this study was to compare the clinical outcomes, radiographic results and the complications between these two methods in patients with displaced proximal humerus fractures. METHODS: In this prospective, randomized clinical trial, 72 patients with displaced fractures of the proximal humerus, classified as Neer 2- or 3-part, were randomly assigned to receive osteosynthesis with either locking plate (36 patients - Plate Group) or locking intramedullary nail (36 patients - Nail Group). The clinical outcomes were evaluated at 3, 6 and 12 months and included the Constant and Murley, University of California at Los Angeles (UCLA) and Disability of Arm, Shoulder and Hand (DASH) scores, visual analog scale (VAS) and the passive range of motion. Radiographic findings (consolidation and head shaft angle) and complications, which included the evaluation of rotator cuff by ultrasound, were also evaluated. The primary outcome was the Constant and Murley score at 12 months. RESULTS: Sixty-five patients completed 12 months of follow-up, 32 in the Nail Group and 33 in the Plate Group. The mean Constant score at 12 months was 70.3 points for the Nail Group and 71.5 points for the Plate Group (p = 0.750) and the mean Relative Constant score was 81% for the Nail Group and 85% points for the Plate Group (p = 0.400). There was also no difference at 3 and 6 months for the Constant score. VAS, DASH and radiographic findings also did not differ at 3, 6 and 12 months. Range of motion showed a 2.1 points difference in favor of the Nail Group for medial rotation at 6 months (p = 0.042), with no difference for the other motions at 3, 6 and 12 months. The UCLA score presented a difference of 4.0 points at 3 months, with better results for the Nail Group (p = 0.005), but no significant difference at 6 and 12 months. Thirty-eight complications were recorded, 28 in the Nail Group and 10 in the Plate Group, with significant difference (p = 0.001). Complications occurred in 18 patients, 11 (34%) of the Nail Group and seven (21%) of the Plate Group, with no significant difference (p = 0.137). CONCLUSIONS: Locking plates and locking intramedullary nail yielded similar clinical and radiographic results. Locking intramedullary nail fixation has a higher risk for complications and reoperations
Bassit, Ana Cristina Ferreira. ""Efeito da terapia por ondas de choque na consolidação óssea após osseossíntese de fêmur com hastes bloqueadas: estudo experimental em cães (canis familiaris)"." Universidade de São Paulo, 2004. http://www.teses.usp.br/teses/disponiveis/5/5160/tde-13092006-140217/.
Full textThe effect of extracorporeal shock wave therapy (ESWT) on bone healing, after bilateral femoral osteotomies and osteosynthesis with interlocking nails, was studied in 8 dogs. The right femurs composed the control group, and the left femurs, the treated group, which received 2000 pulses of shock wave, with 18 kV, 5 mJ (-6dB) energy on the fracture line. Radiographs after 4, 8 and 12 weeks, revealed increased periosteal proliferation in the treated group. The results (treated/control ratio) of the scintigraphic exams, performed on weeks 2, 4, 6, 8, 10 and 12, were statistically higher for the treated group. The ESWT led to increased osteogenic activity on acute fracture's bone healing.
Cavali, Paulo Tadeu Maia 1965. "Estudo clinico das artrodeses cervicais anteriores fixadas com placas e parafusos unicorticais." [s.n.], 2001. http://repositorio.unicamp.br/jspui/handle/REPOSIP/309009.
Full textDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas
Made available in DSpace on 2018-07-28T19:16:25Z (GMT). No. of bitstreams: 1 Cavali_PauloTadeuMaia_M.pdf: 17627848 bytes, checksum: 455e120e8c0e2d9c82cd9222d7885aae (MD5) Previous issue date: 2001
Resumo: O objetivo deste estudo é analisar os resultados das artrodeses cervicais anteriores, fixadas com placas e parafusos unicorticais, utilizados no tratamento de diversas patologias. Quarenta e oito pacientes foram tratados pelo grupo de Cirurgia da Coluna Vertebral da Faculdade de Ciências Médicas, da Universidade Estadual de Campinas (32 homens e 16 muJheres), sendo submetidos à artrodese e à fixação anterior cervical com enxerto autólogo e placa de Morscher. As cirurgias foram realizadas para tratamento de trauma cervical em 16 casos, metástases em 2 casos, hérnia discal em 13 casos, artrose em 14 casos e miscelânea em 3 casos. O tempo médio de seguimento foi de 34 meses e a consolidação ocorreu em 95,8% dos casos. As complicações incluíram cinco casos de soltura do parafuso e 2 casos de fratura de placa. Os resultados demonstraram que a fixação das artrodeses cervicais anteriores com placa de Morscher, em um ou mais níveis, pode promover fixação imediata e estável com alto índice de fusão, preservando a lordose cervical e apresentando baixa incidênciade complicações
Abstract: The purpose of this study is to analyse the results of anterior cervical arthrodesis fixed with plates and unicortical screws in the treatment of different diseases. Forty-eight patients ( 32 males and 16 females ) were treated ftom 1993 until1998 at the Spine Center of the Hospital das Clínicas - Unicamp and submitted to anterior cervical arthrooesis and fixation with autologus bone graft and Morscher cervical plate. The indications for operation were cervical trauma in 16 cases, metastasis in 2 cases, disc hemiation in 13 cases, arthrosis in 14 cases and miscellany in 3 cases. The follow-up was 34 months and consolidation occured in alI cases but two. Complications included 5 cases of screws loosening and 2 cases of plate ftacture. The outcomes show that the Morscher cervical plate can promote immediate and stable fixation with high fusion rate, mantains cervicallordosis and presents a low complication rate
Mestrado
Cirurgia
Mestre em Cirurgia
Andrade, Neto José de Souza. "Avaliação da lipocalina associada à gelatinase de neutrófilos (NGAL) em idosos após osteossíntese de fêmur /." Botucatu, 2015. http://hdl.handle.net/11449/127984.
Full textBanca: Luiz Antonio Vane
Banca: Vera Lucia Fernandes de Azevedo
Resumo: Introdução: A lesão renal aguda (LRA) ocorre em 23% dos pacientes hospitalizados. É responsável por alta morbimortalidade e, ainda assim, não há um marcador precoce e acurado de diagnóstico. Pacientes idosos estão em risco e frequentemente desenvolvem LRA no pós-operatório de grandes cirurgias ortopédicas. Objetivos: Avaliar o biomarcador NGAL plasmático como preditor precoce de LRA no período pós-operatório de fratura de fêmur em idosos. Método: 57 pacientes idosos submetidos à operação de correção de fratura de fêmur foram estudados prospectivamente após 48 horas do pós-operatório. Amostras de sangue foram coletadas para análise de NGAL logo ao término da cirurgia, no período de 4 e 24 horas depois. Amostras da creatinina foram coletadas na admissão hospitalar, 24 e 48 horas no pós-operatório. Foi analisada a acurácia da molécula de NGAL para diagnóstico de LRA. Resultados: Dezesseis (28%) pacientes desenvolveram LRA e apresentaram valores mais elevados de NGAL no plasma com diferença estatística significativa. A análise da área sob a curva Receiving Operator Characteristic demonstrou em 4 horas valor de 0.799 (0.663 a 0.936, p< 0,001); em 24 horas valor de 0.805(0.665 a 0.946, p<0,001). Conclusão: A molécula de NGAL apresentou uma boa acurácia para predição de LRA quando medido após 4 e 24 horas do período pós-operatório
Abstract: Introduction: Introduction: Acute kidney injury is common in hospitalized patients undergoing surgical procedures. It is responsible for a high mortality and yet, there is no early and reliable diagnostic marker. Elderly patients are at risk and often undergo orthopedic procedures as surgical repair of femur fractures. Objectives: To evaluate serum NGAL as a predictor of AKI in the postoperative correction of femur fractures in the elderly. Methodology: 56 elderly patients undergoing surgical repair of femoral fracture were studied prospectively for 48 hours postoperatively. Blood samples were collected for analysis of NGAL after surgery, 4 and 24 hours later. Creatinine measurements collected 24 and 48 hours postoperatively. Accuracy of NGAL was analyzed for diagnosis of acute kidney injury. Results: 16 (28.1%) of patients developed AKI and had significantly higher values of serum NGAL. In 4hours the AUROC = 0799 (0663-0936, p <0.001). In 24 hours the AUROC = 0.805 (0665-0946, p <0001). Conclusion: The molecule of NGAL showed good accuracy for prediction of AKI within 24 hours when measured after 04 hours and 24 hours postoperatively
Mestre