Dissertations / Theses on the topic 'Flash point'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the top 44 dissertations / theses for your research on the topic 'Flash point.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.
Ingram, James Martyn. "Development of an explosimeter for the determination of residual fuel oil head space flammability hazards." Thesis, London South Bank University, 1995. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.336418.
Full textHo, San-Ping. "Water spray suppression and intensification of high flash point hydrocarbon pool fires." Link to electronic thesis, 2003. http://www.wpi.edu/Pubs/ETD/Available/etd-0829103-153046.
Full textRowley, Jeffrey R. "Flammability Limits, Flash Points, and Their Consanguinity: Critical Analysis, Experimental Exploration, and Prediction." BYU ScholarsArchive, 2010. https://scholarsarchive.byu.edu/etd/2233.
Full textCarrion, Domenech Luis Enrique. "Study of high flash point ethyl alcohol-based secondary fluids applied in Ground Source Heat Pumps systems." Thesis, KTH, Skolan för industriell teknik och management (ITM), 2019. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-260335.
Full textEtylalkohol (etanol) som köldbärare är mycket populärt som värmeöverföringsvätska för indirekt kylsystemmed bergvärmepumpsystem (BVP) i Sverige, Norge, Schweiz, Finland och andra europeiska länder. Fleraundersökningar har gjorts om kylsektorns framtid, köldmedier och kylsystem. Dessutom strängaförordningar som F-gas förordning och Kigali- förordning tvingar en utfasning av många nuvarande allmäntanvända köldmedier med den höga globala uppvärmningspotentialen (GWP), dvs. R134a eller R410A. Därför förväntas det att kylsystem och deras köldbärare spela en nyckelroll för att minimera köldmediumsmängd i systemen, minska de indirekta köldmedieläckage och öka säkerheten under drift. Syftet med detta examensarbete är att undersöka effekten av olika tillsatser för att öka flammanpunkten tillsammans med etanolbaserade köldbärare och validera deras termofysikaliska egenskaper genom att jämföra dem med referensvärden för rena etanolvattenlösningar. Studien syftar till att utforma en nykommersiell etylalkoholbaserad produkt för BVP-system som skulle kunna ersätta befintliga produkter på den svenska marknaden och kan arbeta med naturliga eller brandfarliga köldmedier med låg GWP. Olika tillsatser med hög flampunkt testades såsom 1-propylalkohol, n-butylalkohol, glycerol och propylenkarbonat. Termofysikaliska egenskaper undersöktes och en BVP-modell i Excel skapades för att bedöma energiprestanda för olika blandningarna. De erhållna resultaten för olika blandningar visar att glycerol i en låg koncentration som tillsats kan vara framtidens additiv för de etylalkoholbaserade köldbärare på grund av dess höga flampunkt (160 ºC) som förmodligen kan minska brandrisken för etylalkoholblandningar. Dessutom hade glycerol och etanolblandningar den lägsta viskositeten (c.a.12% lägre jämfört med ren etylalkoholblandningar) som bidrar tillen minskning av pumpeffekten med c.a. 4,5% jämfört med rena etylalkoholblandningar. Däremot visade etylalkohol och glycerol blandningen c.a. 4% lägre värmeöverövergångstal jämfört med de rena etylalkoholblandningar på grund av lägre värmeledningsförmåga jämfört med ren etylalkoholblandningar. Slutligen är glycerol en ganska billig och naturlig produkt som inte har några korrosionsproblem eftersom etylalkohol och glycerol är mindre frätande än vatten. Även om flampunkttest inte genomfördes i projektet, förväntas det att flampunkten ökas lite på grund av den höga flampunkten av glycerol jämfört med etylalkohol och andra tillsatser. Därför förväntas det att brännbarhetsrisken förknippad med etylalkoholbaserade köldbärare reduceras.
Carareto, Natalia Daniele Dorighello 1984. "Solid-liquid equilibrium and flash point of fatty mixtures = Equilíbrio sólido-líquido e ponto de fulgor de misturas graxas." [s.n.], 2014. http://repositorio.unicamp.br/jspui/handle/REPOSIP/255155.
Full textTese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos
Made available in DSpace on 2018-08-24T15:58:48Z (GMT). No. of bitstreams: 1 Carareto_NataliaDanieleDorighello_D.pdf: 2781126 bytes, checksum: a569200223f2c962deb5f7e6129613dd (MD5) Previous issue date: 2014
Resumo: O estudo das propriedades físico-químicas de materiais graxos é uma demanda mundial crescente, principalmente devido ao incentivo do seu uso como fonte de energia e para a alimentação. Faz-se importante estudar e compreender todas as condições de equilíbrio que podem ser observadas durante o processamento de compostos graxos, por exemplo, óleos vegetais e biodieseis, desde a sua extração, refino e estocagem. Dados de equilíbrio sólido-líquido podem ser usados para melhorar ou propor novos processos de separação. Já o ponto de fulgor é uma propriedade importante que deve ser observada no armazenamento, transporte e produção de compostos inflamáveis, como o biodiesel. Este trabalho teve como objetivos estudar o equilíbrio sólido-líquido de misturas binárias graxas formadas por álcoois graxos, ésteres graxos ou ácidos graxos, e avaliar o ponto de fulgor de misturas de ésteres etílicos, que são constituintes principais de biodieseis, e etanol, presente em teores residuais. Os pontos de fulgor de ésteres etílicos, e também de misturas binárias destes ésteres com etanol foram determinados experimentalmente e a partir dos resultados foi proposto um modelo empírico para a predição do ponto de fulgor de biodieseis em função da sua composição e teor de etanol. Os diagramas de equilíbrio sólido-líquido de sistemas binários formados por ácidos + álcoois graxos ou formados por álcoois + álcoois graxos foram determinados experimentalmente através de calorimetria exploratória diferencial (DSC) com a intenção de melhor compreender as reações eutética, peritética e metatética que aparecem nos diagramas de equilíbrio tanto com taxas de aquecimento linear ou via o uso da ferramenta de stepscan DSC. Para complementar o estudo foram usadas técnicas de difração de Raios-X e microscopia óptica com controle de temperatura. O efeito da pressão sobre o equilíbrio sólido-líquido foi avaliado para misturas binárias de ésteres etílicos ou de álcoois graxos utilizando-se microscopia ótica acoplada a um aparato experimental que permite o aumento da pressão até 80 MPa. Foram utilizados os modelos termodinâmicos para coeficiente de atividade Margules 2 e 3-sufixos e NRTL para descrever a linha liquidus dos sistemas que apresentaram ponto peritético, e um modelo termodinâmico preditivo foi aplicado para modelar o ESL em função da pressão e, em ambos os casos, obteve-se um ajuste satisfatório em comparação aos dados experimentais
Abstract: The study on the physicochemical properties of fatty materials has acquired a growing importance, mainly due to the incentive of their use in energy and nutrition. The efficient production and use of fatty compounds requires a good knowledge of their properties and phase behavior that are necessary for development of processes, especially in production steps such as extraction and refining, but also during storage of the final products. Solid-liquid equilibrium data can be used to improve or propose new separation processes. Also the flash point is an important property that must be considered during storage, transportation and production of flammable compounds, such as biodiesel. This work aimed to study the solid-liquid equilibrium of binary mixtures consisting of fatty alcohols, fatty esters or fatty acids, and to evaluate the flash point of mixtures of ethyl esters, the major constituents of biodiesels, and ethanol, also present in biodiesel in residual levels. Flash points of ethyl esters, and also of the binary mixtures of ethyl esters with ethanol were determined experimentally. An empirical model for predicting the flash point of biodiesels as a function of composition and ethanol content was proposed. The solid-liquid phase diagrams of binary mixtures of fatty alcohol + fatty alcohol or fatty alcohols + fatty acid were determined experimentally by differential scanning calorimetry (DSC), using a linear heating rate, or by a stepscan DSC method, with the aim of investigating the occurrence of the eutectic, peritectic and metatectic reactions. X-ray diffraction and optical microscopy with temperature control techniques were applied to complement the understanding of the phase diagrams. The effect of pressure on the solid-liquid equilibrium was investigated for the binary mixtures of ethyl esters or fatty alcohols using an optical microscope coupled to a high pressure cell which allows the pressure increase up to 80 MPa. Margules 2 and 3-suffix and NRTL thermodynamic models were used for describing the liquidus line of the systems that presented peritectic point, and a predictive thermodynamic model was used to model the ESL function of pressure, which in both cases, gave a satisfactory fit compared to the experimental data
Doutorado
Engenharia de Alimentos
Doutora em Engenharia de Alimentos
Mattos, Rodrigo Alves de 1979. "Estudo da influência de aditivos naturais nos pontos de entupimento a frio, de turbidez e de fulgor de biodiesel e de misturas diesel-biodiesel." [s.n.], 2012. http://repositorio.unicamp.br/jspui/handle/REPOSIP/248843.
Full textTese (doutorado) - Universidade Estadual de Campinas, Instituto de Química
Made available in DSpace on 2018-08-21T17:49:21Z (GMT). No. of bitstreams: 1 Mattos_RodrigoAlvesde_D.pdf: 2518556 bytes, checksum: a8c7635c9785df284e4cea0c8053443c (MD5) Previous issue date: 2012
Resumo: O presente trabalho foi realizado usando biodieseis preparados a partir de óleos de soja, canola, milho, girassol e, também, de gordura suína, através de reações transesterificação. Para todos esses biodieseis foram determinados o ponto de entupimento a frio, o ponto de fulgor e o perfil cromatográfico. Estes biodieseis foram misturados com diesel de petróleo para se produzir misturas contendo 5% do biocombustível (B5), 10% (B10) e 20% (B20), e os ensaios citados foram realizados nestas amostras. Visando a diminuição do ponto de entupimento a frio, alguns aditivos naturais foram testados e se mostraram eficientes. Por exemplo, o limoneno reduziu o ponto de entupimento do biodiesel de óleo soja em mais de 7°C. No biodiesel de gordura suína a redução foi de 10°C, o que significa o ponto de entupimento a frio em temperatura inferior a 13°C. Os aditivos utilizados são solúveis nos biodieseis estudados e, também, nas misturas diesel-biodiesel, pelo menos nas concentrações testadas. Como importante exemplo de abaixamento do ponto de entupimento a frio das misturas diesel-biodiesel de gordura suína com 10% de biodiesel (B10), podese citar o caso da terebentina que provocou uma redução de aproximadamente 8°C (de 12,7ºC para 5,0°C). Este mesmo aditivo caus ou uma redução de 13,6 ºC (de 20,3ºC para 6,7ºC), na mistura diesel-biodiesel de gordura suína com 20% de biodiesel (B20). Este resultado é muito significativo por implicar na possibilidade de usar este tipo de combustível mesmo em regiões mais ao sul do país durante o inverno
Abstract: The present studies were performed preparing biodiesel from soya, canola, corn, sunflower oils and the fat swine, through transesterification reaction. The biodiesel produced from these oils were studied for: cold filter plugging point, flash point and for chromatographic analysis. The biodiesels were mixed with diesel to produce blends containing 5% of the biofuel (B5), 10% (B10) and 20% (B20), and these samples were also analyzed by the same techniques as discussed earlier. In order to decrease the cold filter plugging point, some natural additives have been tested and were proved effectively. For example, limonene caused more than 7°C reduction in the cold filter plugging point of soybean biodiesel. In the biodiesel obtained from the swine fats, the reduction was found around 10°C and less than 13°C for the cold filter plugging point. The additives are soluble in studied biodiesels and also in the dieselbiodiesel blends, at least, in the concentrations tested. One of the important example of the reduction in the cold filter plugging point of diesel-biodiesel blends of swine fats with 10% biodiesel (B10), using turpentine as additive which caused reduction of approximately 8°C (from 12,7ºC up to 5,0°C). The same additive caused a reduction of 13,6 ºC (from 20.3 ºC up to 6.7 °C) in the cold filter plugging point of diesel -biodiesel blends of swine fats with 20% biodiesel (B20). This result is very significant because it is possible to use this type of fuel in south regions of the country during the winter
Doutorado
Quimica Analitica
Doutor em Ciências
Balingit, JoAnn Alegre. "Internet plagiarism as flash point and folklore / do high school students plagiarize more from Internet sources than from print-based sources?" Access to citation, abstract and download form provided by ProQuest Information and Learning Company; downloadable PDF file, 144 p, 2008. http://proquest.umi.com/pqdweb?did=1654487881&sid=3&Fmt=2&clientId=8331&RQT=309&VName=PQD.
Full textDorighello, Carareto Natalia Daniele. "Equilibre solide-liquide et point d'éclair de mélanges de corps gras." Thesis, Pau, 2014. http://www.theses.fr/2014PAUU3048.
Full textThe study on the physicochemical properties of fatty materials has acquired a growing importance, mainly due to the incentive of their use in energy and nutrition. The efficient production and use of fatty compounds requires a good knowledge of their properties and phase behavior that are necessary for development of processes, especially in production steps such as extraction and refining, but also during storage of the final products. Solid-liquid equilibrium data can be used to improve or propose new separation processes. Also the flash point is an important property that must be considered during storage, transportation and production of flammable compounds, such as biodiesel. This work aimed to study the solid-liquid equilibrium of binary mixtures consisting of fatty alcohols, fatty esters or fatty acids, and to evaluate the flash point of mixtures of ethyl esters, the major constituents of biodiesels, and ethanol, also present in biodiesel in residual levels. Flash points of ethyl esters, and also of the binary mixtures of ethyl esters with ethanol were determined experimentally. An empirical model for predicting the flash point of biodiesels as a function of composition and ethanol content was proposed. The solid-liquid phase diagrams of binary mixtures of fatty alcohol + fatty alcohol or fatty alcohols + fatty acid were determined experimentally by differential scanning calorimetry (DSC), using a linear heating rate, or by a stepscan DSC method, with the aim of investigating the occurrence of the eutectic, peritectic and metatectic reactions. X-ray diffraction and optical microscopy with temperature control techniques were applied to complement the understanding of the phase diagrams. The effect of pressure on the solid-liquid equilibrium was investigated for the binary mixtures of ethyl esters or fatty alcohols using an optical microscope coupled to a high pressure cell which allows the pressure increase up to 80 MPa. Margules 2 and 3-suffix and NRTL thermodynamic models were used for describing the liquidus line of the systems that presented peritectic point, and a predictive thermodynamic model was used to model the ESL function of pressure, which in both cases, gave a satisfactory fit compared to the experimental data
Fregolente, Lernardo Vasconcelos 1980. "Aplicação de planejamento de experimentos em diferentes etapas do refino de petroleo." [s.n.], 2009. http://repositorio.unicamp.br/jspui/handle/REPOSIP/266397.
Full textTese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica
Made available in DSpace on 2018-08-12T16:55:11Z (GMT). No. of bitstreams: 1 Fregolente_LeonardoVasconcelos_D.pdf: 1867297 bytes, checksum: 6a22c8c7c525474c0864d4df237dce16 (MD5) Previous issue date: 2009
Resumo: Neste trabalho, a técnica de planejamento de experimentos foi aplicada em diferentes estudos de otimização realizados na Refinaria de Paulínia (Replan). O trabalho abrange aplicações da técnica em escala laboratorial, em ferramenta computacional, até a utilização da técnica em diferentes plantas industriais. Os estudos de laboratórios consistiram na avaliação da dependência da lubricidade do diesel metropolitano em relação à sua composição e no desenvolvimento de uma nova metodologia para determinação do ponto de fulgor de frações leves de petróleo. Através de planejamentos fatoriais aplicados a um simulador do processo de coqueamento retardado (denominado DC-SIM), foram geradas equações polinomiais simples para a previsão de rendimentos dos produtos da unidade em sua etapa reacional. Utilizando estas equações, curvas de nível foram obtidas, as quais auxiliam na análise do comportamento da unidade frente a modificações nas condições de operação. Duas aplicações consistiram na realização de testes em plantas industriais. Primeiramente, utilizando planejamentos em dois níveis, foram levantados novos modelos para o controle avançado de uma torre de fracionamento de naftas através da realização de testes de identificação utilizando perturbações em degrau. A metodologia de planejamento de experimentos possibilitou uma análise multivariável do sistema. Finalmente, foram realizados experimentos seguindo planejamentos com configuração estrela para a maximização da recuperação de moléculas na faixa de destilação do GLP nas áreas de fracionamento de gases das duas unidades de coqueamento retardado da Replan. Por se tratar da maior refinaria de petróleo do país, sendo responsável por cerca de 20% da capacidade de refino no Brasil, a utilização de planejamentos fatoriais foi de fundamental importância para a viabilização de alguns testes em planta, já que reduz significativamente o número de experimentos necessários quando comparada à metodologia de avaliação de um fator por vez. Desta forma, o impacto dos testes na produção de derivados foi minimizado. Além disso, os resultados obtidos propiciaram um ganho econômico expressivo para a refinaria.
Abstract: In this work, experimental design technique was applied to different optimization studies, which were carried out in the Paulínia Refinery (Replan). The work covers applications of the technique in laboratorial scale, in computational tool, and the use of the technique in different industrial plants. The laboratory studies consisted in the evaluation of the dependence of the metropolitan diesel oil lubricity in relation to its composition and in the development of a new methodology to determine the flash point of light fractions of petroleum. Through factorial designs applied to a delayed coke simulator (named DC-SIM), simple polynomial equations were generated to predict the products yields of the unit in the reaction step. Using these equations, contour plots were obtained, which helped the analysis of the process response due to changes in the operating conditions. Two applications were done in industrial plants. First, using two level factorial designs, new models were adjusted to be used in the advanced control of a naphtha fractionation tower. The identification tests were carried out giving step disturbance in the manipulated variables. The experimental design methodology allowed a multivariable analysis of the system. Finally, experiments were done according to star configuration factorial designs in order to maximize the recovery of LPG molecules in the gases fractionating units of two delayed coke plants of Replan. Since Replan is the biggest oil refinery in Brazil, responsible for 20% of the national refining capacity, the use of factorial designs had a fundamental importance to allow the running of some tests in the plant. It reduces significantly the number of experiments, when it is compared to univariate methodology. Therefore, the impact of the tests in the production was minimized. Furthermore, the results provided very expressive financial earns
Doutorado
Desenvolvimento de Processos Químicos
Doutor em Engenharia Química
Silveira, Eva Lúcia Cardoso 1981. "Desenvolvimento de novas propostas para análise de bioesel e estudo da relação entre ponto de fulgor e o teor de álcool reiduol." [s.n.], 2012. http://repositorio.unicamp.br/jspui/handle/REPOSIP/248838.
Full textTese (doutorado) - Universidade Estadual de Campinas, Instituto de Química
Made available in DSpace on 2018-08-21T09:33:03Z (GMT). No. of bitstreams: 1 Silveira_EvaLuciaCardoso_D.pdf: 1544784 bytes, checksum: 21e0e9cae43209115424068ca5568476 (MD5) Previous issue date: 2012
Resumo: Um método de baixo custo é proposto neste trabalho para a análise quantitativa do álcool residual em biodiesel através da determinação do ponto de fulgor. Foram analisados ésteres metílicos obtidos de óleos de soja, milho, girassol e de sebo bovino. Os ésteres etílicos foram obtidos de óleo de soja. Em todos os casos ficou evidente que há uma correlação entre o ponto de fulgor e o teor de álcool residual no biodiesel. Assim, o parâmetro ponto de fulgor pode ser usado diretamente para determinar o teor de álcool residual do biodiesel. Foi proposto também um método para a determinação de fósforo em biodiesel por espectrofotometria de absorção molecular UV-Vis. As amostras de biodiesel são mineralizadas por calcinação a 550 °C seguindo dissolução do resíduo em H2SO4 1,0 mol L. O procedimento analítico é baseado na formação do complexo azul de molibdênio. Empregou-se o ácido 1-amino-2-naftol-4-sulfônico como agente redutor. O método foi aplicado para amostras de biodiesel de soja, canola, girassol e de sebo bovino. Os limites de detecção e quantificação obtidos para fósforo foram de 0,57 mg kg e 1,71 mg kg, respectivamente. O desvio padrão relativo médio obtido foi cerca de 5 %. A simplicidade do procedimento adicionado à precisão, exatidão e o baixo custo indicam que é uma excelente opção para a determinação de fósforo em biodiesel. Um terceiro método, neste caso, para a determinação de ânions em biodiesel baseado na extração com água assistida por ultrassom também foi desenvolvido neste trabalho. Os extratos obtidos das amostras de biodiesel foram analisados por cromatografia de íons. Os limites de quantificação foram 0,97; 4,10; 0,30; 2,47 e 0,26 mg kg para acetato, formiato, cloreto, fosfato e sulfato, respectivamente. A técnica de cromatografia de íons mostrou-se viável para a separação e quantificação de ânions orgânicos e inorgânicos em biodiesel simultaneamente diminuindo assim o tempo de análise
Abstract: A low cost method is proposed in this work for the quantitative analysis of residual alcohol in biodiesel through determination of the flash point. We analyzed methyl esters obtained from oils such as soy, corn, sunflower and of bovine fat. The ethyl esters were obtained from soy oil. In all cases it became very evident that there is a correlation between the flash point and the residual alcohol content in the biodiesel. Therefore the parameter flash point can be used to directly determine the residual alcohol content of biodiesel. A method has been proposed for the determination of phosphorus in biodiesel by UV-vis molecular absorption spectrophotometry. The biodiesel samples are mineralized using an ashing procedure at 550 °C following dissolution of the residue in 1.0 mol L H2SO4. The analytical procedure is based on the formation of a blue molybdenum complex. 1-amino-2naphthol-4-sulfonic acid is used as reducing agent. The method was applied to biodiesel samples of soy, canola and sunflower oils and of bovine fat. The limits of detection and quantification are 0.57 mg kg and 1.71 mg kg, respectively. The average standard deviation obtained was about 5 %. The simplicity of the procedure added to its precision, accuracy and low cost indicate that it is an excellent option for the determination of phosphorus in biodiesel. A third method, in this case, for the determination of anions in biodiesel based on extraction with ultrasound assisted water has also been developed in this study. The extracts of biodiesel samples were analyzed by ion chromatography. The limits of quantification obtained were 0.97, 4.10, 0.30, 2.47 and 0.26 mg kg for acetate, formate, chloride, phosphate and sulfate, respectively. The technique of ion chromatography proved to be feasible for the simultaneously separation and quantification of organic anions in biodiesel, thereby reducing analysis time
Doutorado
Quimica Analitica
Doutora em Ciências
Gao, Hantian. "Nanoscale Characterization and Control of Native Point Defects in Metal Oxide Semiconductors and Device Structures." The Ohio State University, 2021. http://rave.ohiolink.edu/etdc/view?acc_num=osu1618838504594148.
Full textMazoyer, Pascale. "Analyse et caractérisation des mécanismes de perte de charge relatifs aux diélectriques multicouches du point mémoire EPROM." Université Joseph Fourier (Grenoble), 1994. http://www.theses.fr/1994GRE10009.
Full textKrištofík, František. "Stabilita aprotických elektrolytů v lithno-iontových akumulátorech." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2014. http://www.nusl.cz/ntk/nusl-220955.
Full textJosyula, Sai Prashanth. "On the Applicability of a Cache Side-Channel Attack on ECDSA Signatures : The Flush+Reload attack on the point multiplication in ECDSA signature generation process." Thesis, Blekinge Tekniska Högskola, Institutionen för datalogi och datorsystemteknik, 2015. http://urn.kb.se/resolve?urn=urn:nbn:se:bth-10820.
Full textDoležal, Filip. "Administrativní objekt - Brno,Medlánky." Master's thesis, Vysoké učení technické v Brně. Fakulta stavební, 2018. http://www.nusl.cz/ntk/nusl-371890.
Full textAyvazyan, Vigen. "Etude de champs de température séparables avec une double décomposition en valeurs singulières : quelques applications à la caractérisation des propriétés thermophysiques des matérieux et au contrôle non destructif." Thesis, Bordeaux 1, 2012. http://www.theses.fr/2012BOR14671/document.
Full textInfrared thermography is a widely used method for characterization of thermophysical properties of materials. The advent of the laser diodes, which are handy, inexpensive, with a broad spectrum of characteristics, extend metrological possibilities of infrared cameras and provide a combination of new powerful tools for thermal characterization and non destructive evaluation. However, this new dynamic has also brought numerous difficulties that must be overcome, such as high volume noisy data processing and low sensitivity to estimated parameters of such data. This requires revisiting the existing methods of signal processing, adopting new sophisticated mathematical tools for data compression and processing of relevant information.New strategies consist in using orthogonal transforms of the signal as a prior data compression tools, which allow noise reduction and control over it. Correlation analysis, based on the local cerrelation study between partial derivatives of the experimental signal, completes these new strategies. A theoretical analogy in Fourier space has been performed in order to better understand the «physical» meaning of modal approaches.The response to the instantaneous point source of heat, has been revisited both numerically and experimentally. By using separable temperature fields, a new inversion technique based on a double singular value decomposition of experimental signal has been introduced. In comparison with previous methods, it takes into account two or three-dimensional heat diffusion and therefore offers a better exploitation of the spatial content of infrared images. Numerical and experimental examples have allowed us to validate in the first approach our new estimation method of longitudinal thermal diffusivities. Non destructive testing applications based on the new technique have also been introduced.An old issue, which consists in determining the initial temperature field from noisy data, has been approached in a new light. The necessity to know the thermal diffusivities of an orthotropic medium and the need to take into account often three-dimensional heat transfer, are complicated issues. The implementation of the double singular value decomposition allowed us to achieve interesting results according to its ease of use. Indeed, modal approaches are statistical methods based on high volume data processing, supposedly robust as to the measurement noise
Hsu, Wen-Chi, and 許文綺. "The Extreme Flash Point Behavior of Ternary Mixtures- The Maximum-Minimum Flash Point." Thesis, 2017. http://ndltd.ncl.edu.tw/handle/nmffp8.
Full text國立高雄第一科技大學
環境與安全衛生工程系碩士班
105
The flash point is one of the most important parameters for evaluating the fire and explosion hazards of flammable liquids. The extreme flash point behavior of binary mixtures including the maximum flash point and the minimum flash point. Most of the researches of extreme flash point limited in binary system. However, in the real world, muti-component solutions are used more frequently. In previous study, the minimum flash point behavior of ternary mixture was discussed. However, there is no study discussed about the ternary mixtures which show max-minimum flash point behavior. If we can predict the Max-MinFPB of ternary mixture, it can be applied in hazard reduction and avoiding the potential hazard of fire and explosion on process operation, so this study focus on the Maximum-minimum flash point behavior of ternary mixtures. Beside the experiment data, we also use the prediction model to predict the flash point of mixture which developed for flammable mixtures by Liaw et al. The substances selected included phenol+cyclohexanol+isoamyl butyrate and phenol+1-octanol+acetophenone. Both of them have maximum and minimum flash point. One of the result for the two studied ternary mixtures which have Max-Min flash point in this study is the maximum flash point is the maximum flash point of binary constituent, and the minimum flash point is the minimum flash point of binary constituent. The maximum flash point behavior increase the flash point of mixtures foe the two mixtures. This result can be applied in the hazard reduction of fire and explosion and the design of process operation.
Li, Yi-Hua, and 李依樺. "Flash point prediction by UNIFAC approach." Thesis, 2009. http://ndltd.ncl.edu.tw/handle/64489391655243426974.
Full text中國醫藥大學
職業安全衛生學系碩士班
97
The implementation of GHS (Globally Harmonized System of Classification and Labeling of Chemicals) is the international trend, and Taiwan has implemented GHS since 2008. In the implementation of GHS, the flash point of mixtures is the critical property to classify flammable liquids. The flash point value of liquids is the primary parameter in hazard classification for the flammable liquids. If a flash point prediction model for mixtures is developed, the flash point of mixtures can be estimated rapidly and economically, and it is helpful in the promotion of GHS. The problem of classification of flammable liquids was faced in 2008 in Taiwan, and it is urgently and immediately necessary to be resolved. This study is to give a solution for the estimation of flash point for mixtures, the necessity for classification of flammable liquids. The traditional models for predicting flash point of mixtures usually by the activity coefficient approach. However, the parameters of activity coefficient were regressed from phase equilibrium data in the literatures. If there is no such parameter in literatures for the desired mixture, the model cannot predict the flash point oft hat mixture. Thus, this research aims at the improvement of deficiency of the flash point prediction models in the literatures by useing UNIFAC (Universal Quasi-chemical Functional Group Activity Coefficient) equation, Dortmund-UNIFAC equation and Lyngby-UNIFAC equation. In this study, we were aim at the prediction model for miscible mixtures. From the result, it is suggested to use different type of UNIFAC equation to estimast activivity coefficient in the predition of flash point for different mixture type. In addition to the academic value, the result can be applied to help the government and industries to promote the implementation of GHS. Potential application for the model concerns the assessment of fire and explosion hazards, and the development of inherently safer designs for chemical processes.
LIOU, JYUN-SIAN, and 劉俊賢. "The Study of Flash Point Behavior for Ternary Mixture with Three Binary Constituents Exhibiting Maximum Flash Point." Thesis, 2018. http://ndltd.ncl.edu.tw/handle/jfd2r7.
Full text國立高雄第一科技大學
環境與安全衛生工程系碩士班
106
Flammable mixtures have the risk of fire and explosion hazards. The flash point is one of the important reference factors for risk assessment. The composition of the flammable mixture is different, and the flash point behavior is also different. It has been shown in the literature that the binary mixture has the maximum or minimum flash point behavior. In real world, multi-component solutions are used more frequently, and the simplest combination of multi-component mixtures is a ternary mixture. In previous study, the minimum flash point behavior of ternary mixtures was discussed, but the study of the maximum flash point behavior of a ternary mixtures is less. Therefore, this study will investigate the maximum flash point behavior of the ternary mixtures. In the study, we used prediction model of the flash point of a ternary flammable liquid proposed by Liao et al., and used the experimental data as proof. Finally, we discuss the flash point behavior of the ternary mixture. The substances selected included phenol+cycloheptanol+4-tertbutylpyridine and phenol+cycloheptanol+3-butylpyridine. Both have maximum flash point behavior. In this study, we used a flash point analyzer made by Eralytics for analysis and used the ASTM D7094 standard test method of the American Society for Testing and Materials. According to the experimental results of the two studies of ternary mixtures, the maximum flash point is the maximum flash point of binary mixture. According to the characteristics of the maximum flash point behavior, the flash point of the mixture can be increased. This result can be used to reduce the risk of fire and explosion, and can provide a study of the flash point of negative deviation solution.
Chun, Lin Shen, and 林聖鈞. "Binary mixtures exhibiting maximum flash-point behavior." Thesis, 2005. http://ndltd.ncl.edu.tw/handle/22056522365788263759.
Full text中國醫藥大學
環境醫學研究所
93
The flash-point specification is one of the major safety data items specified in the typical material safety data sheet, but even those listed in a variety of MSDS sheet are, typically, only valid for a pure and specific compound composition. The existence of maximum flash-point solution was demonstrated in this study. The behavior of such a solution has the potential to be applied in hazard reduction. The sufficient condition for a binary mixture to form a maximum flash-point solution and the equations to determine the maximum flash-point composition and maximum flash-point are proposed here. The derivative of flash point with respect to composition derived previously, which was based upon the flash point-prediction model proposed in a previous study, was applied to derive both the sufficient conditions and equations referred to above. Such a condition and equations both were verified by comparison of predicted results with experimentally derived data. The results reveal that this derived condition is satisfactory for the identification of the status of a liquid solution as being a maximum flash-point solution and the proposed equations satisfactory to successfully estimate the value of the maximum flash-point composition and the maximum flash point. The Flash Point Analyzer, HFP 362-Tag, manufactured by Walter Herzog GmbH (Germany) was used to measure the flash point of liquid solutions associated with different composition as tests. The Flash Point Analyzer is operated according to the standard test method, ASTM D56.
Chen, Hao-Ying, and 陳皓楹. "Investigation of the Ionic Liquid’s Flash Point." Thesis, 2013. http://ndltd.ncl.edu.tw/handle/8dcy38.
Full text中國醫藥大學
職業安全與衛生學系碩士班
101
The ionic liquid is considered to be a green solution (the Ionic Liquids ILS).They have a high degree of thermal stability and low volatility. It is proven to be replaced by volatile organic solvents, and can be widely used in other areas. Recently, ionic liquids have been confirmed flammable and classified in a flash point greater than 93 ° C above the liquid Class III B. Most of the research was on the application, unless to discuss about flash point. Studies have demonstrated the generation mechanism of the ionic liquid Flash point is different from the traditional organic solvents. The flash point of ionic liquids can’t be confused with traditional organic solvents. In this research, we use Thermogravimetric analysis (TGA), Fourier Transform Infrared Spectroscopy (FTIR) and Flash point tester. We use seven kind of the sample are [C6mim] [Cl], [C4mim] [Cl], [C4mim][ NTf2] [C6mim][NTf2],[C2mim][NTf2], [C10mim][NTf2], [C12mim][NTf2]. Among, [C6mim][Cl] and [C2mim] [NTf2] have been tested in different heating temperatures and use of the FTIR measurements the product of finished testing the flash point. We hope to use the results to identify that the reason of the ionic liquid flash point. In this study, we use the isothermal TGA test [C2mim][NTf2] and [C4mim][NTf2] calculated the kinetic parameters. The results of this study can be used in the prediction flash point of the ionic liquid. And then, the results can be used in hazardous classification of ternary mixtures, and can be applied in process safety design and hazard reduction.
Chen, Yi-Chien, and 陳怡蒨. "A study of the flash point for ionic liquids." Thesis, 2010. http://ndltd.ncl.edu.tw/handle/96700143045935711584.
Full text中國醫藥大學
職業安全衛生學系碩士班
98
This study used dynamic thermogravimetry and FTIR to analyze the gas phase composition before and after the pyrolysis of ionic liquids. The method proposed in literature by use of the thermal diagram of DSC and TGA to estimate the flashpoint of ILs was used and the results were compared with those obtained from flash point tester. A new proposed method by use the tested isothermal TGA decomposition rate at different temperature was tested and was used to estimate the pyrolysis kinetic parameters of ionic liquids. Finally, the estimated flashpoints of ILs were compared with the experimental data. The flash point of ionic liquids was tested by the Flash point tester (Walter Herzog GmbH Pensky-Martens HFP 360). The decomposition behavior of ionic liquids was analyzed by the thermogravimetric analyzer (Mettler Toledo TGA/SDTA851e) and Differential scanning calorimetry (Mettler Toledo DSC821e). The FTIR Multicomponent (FTIR Gas Analyzer GASMET Dx-4015) was used to analyze gas phase composition of the pyrolysis products of ionic liquids. The results tested from dynamic thermogravimetry and FTIR indicated that the gas phase compositions were different. It demonstrated that the estimation of flashpoint of ionic liquids from TGA decomposition data is not appropriate. The method proposed in this study by use of the pyrolysis kinetic parameters from isothermal TGA decomposition rate of ionic liquids. The estimation of flashpoint by use of TGA decomposition data will underestimate the fire and explosion hazard of ionic liquids. By use of the kinetic parameters to estimate flashpoint of ILs proposed in this study give an accuracy result, and reduce the cost of flash point testing.
Wu, Yu-Shan, and 吳玉珊. "Predictive model of flash point for pure organic substances." Thesis, 2006. http://ndltd.ncl.edu.tw/handle/79bmp7.
Full text國立中央大學
化學工程與材料工程研究所
94
Organic substances are used in manufacture processes widely. These substances have many hazardous characters, including toxicity, corrosion, and flammability or combustibility. The flammability has the most concern. Furthermore, flash point is usually used as a flammable index for describing flammability of substances. A predictive model of flash point for organic substances based on the group contribution method is proposed in the study. User can use this model by the groups involving in substance molecule to calculate the flash point without other properties. And building up the predictive model without any restriction is the target of this study.
邱益裕. "the prediction of the flash point for aqueous-organic solutions." Thesis, 2003. http://ndltd.ncl.edu.tw/handle/27968442054698482826.
Full text中國醫藥學院
環境醫學研究所
91
A mathematical model for predicting a binary aqueous-organic solutions and an analogous model for predicting the flash point of multiple components aqueous-organic solutions has been proposed, in order to predict the flash point for multi-component solutions. The binary aqueous-organic solutions, water + methanol, water + ethanol, water + n-propanol, and water +2-propanol were used as an example to valid this proposed model for a binary aqueous-organic solutions. The results were plotted against the predictive curves from the flash point prediction model and those simulated by the model described by Crowl & Louvar. The method described by Crowl & Louvar can only be used to estimate the flash point of a binary aqueous-organic solution for the composition range of water composition close to zero, and can not be applied to the composition range of water composition apart from unity. The results reveal that this model is able to precisely predict the flash point over the entire composition range of binary aqueous-organic solutions by way of utilizing the flash-point data pertaining to the flammable component. The ternary aqueous-organic solutions, water + methanol + ethanol, and water + methanol +2-propanol were used as an example to valid this proposed model for a termary aqueous-organic solutions. The results reveal that the model is able to precisely predict the flash point over the entire composition range of multiple components aqueous-organic solutions by way of utilizing the flash point of the individual components. If the binary parameters for a ternary solution are not accessible, such a model based upon the binary parameters of binary solutions may provide a very acceptable means of predicting flash point for a ternary solution as revealed by a comparison between predicted and experimental data. The composition effect on flash point derived in this manuscript can be used in the analysis of the sensitivity of flash point variation for dilution with water, and such a result can be applied in the process safety design/operation to decide if the dilution of a flammable liquid with water is effective at specified composition.
Huang, Yu-chian, and 黃渝茜. "Analysis of Decomposition Products of Ionic Liquid at Flash Point." Thesis, 2015. http://ndltd.ncl.edu.tw/handle/60238322986355246536.
Full text國立高雄第一科技大學
環境與安全衛生工程研究所
103
Ionic Liquids have a high degree of thermal stability, catalyst and extremely low vapor pressure. It as a green solvent and proven to be replaced by volatile organic solvents in industry. Recently, research has been verified that ionic liquids is flammable and be classified in a flash point greater than 93℃ above the liquid Class III B. The reason for ionic liquids combustible is different from the traditional organic solvents defined liquids. The flash point for traditional organic solvent are relative to their vapor pressures, but the cause of flash point for ionic liquid is combustible to vapor pressures.The flash point of ionic point is caused by decomposition. This study is used the Thermogravimetric analysis (TGA) and fourier transform infrared spectroscopy (FTIR) to measure 1-ethyl-3methylimidazolium ethyl sulfate ([Emim][EtSO4])、1-hexyl-3-methylimidazolium chloride ([C6mim][Cl]) and 1-butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([Bmim][NTf2]). Analysis of decomposition products of ionic liquid flash point by TGA/FTIR is helpful for investigation of the ionic lipqid’s flash point. In this study found that ionic liquid near the flash point will decompose the flammable gas like methanol, ethen, chloromethane etc. Realizing the cause for flammability of ionic liquid is helpful for fire, explosion hazard, process safety design and harzard reduction.
Chen, Chien-Tsun, and 陳建村. "The flash-point prediction for binary partially miscible aqueous-organic solutions." Thesis, 2007. http://ndltd.ncl.edu.tw/handle/61126106979825604276.
Full text中國醫藥大學
職業安全衛生學系碩士班
95
Flash point is the most important variable used to characterize fire and explosion hazard of liquids. Herein, partially miscible mixtures are presented within the context of liquid-liquid extraction processes. This paper describes development of a model for predicting the flash point of binary aqueous-organic solutions with partial miscibility. To confirm the predictive efficacy of the derived flash points, the model was verified by comparing the predicted values with the experimental data for the studied mixtures: water + 1-butanol; water + 2-butanol; water + isobutanol; water + 1-pentanol; and, water + 1-octane. Our results reveal that immiscibility in the two liquid phases should not be ignored in the prediction of flash point. Overall, the predictive results of this proposed model describe the experimental data well. Based on this evidence, therefore, it appears reasonable to suggest potential `application for our model in assessment of fire and explosion hazards, and development of inherently safer designs for chemical processes containing binary partially miscible mixtures of water with one flammable solvent.
Tsai, Tsung-Pin, and 蔡琮彬. "The flash point prediction for partially miscible system by UNIFAC approach." Thesis, 2012. http://ndltd.ncl.edu.tw/handle/55587572217030035061.
Full text中國醫藥大學
職業安全與衛生學系碩士班
100
The partially miscible mixtures are used in heterogeneous distillation process and liquid-liquid extraction process. This research aims at the deficiency improvement of necessity of experimental interaction parameters for the flash point prediction models proposed in the literatures by using UNIFAC (Universal Quasi-chemical Functional Group Activity Coefficient) type models. In this study, we were aim at the prediction model for partially miscible mixtures. The partially miscible aqueous-organic mixtures and the partially miscible mixtures of flammable solvents were used to verify the prediction capability of the method. Our results revealed that the combined model is able to represent well the measured flash point over the entire flammable composition range of all studied binary and ternary mixtures, although there are some deviations in the estimated region of two liquid phases. However, we can predict the flash point of binary partially miscible mixtures without experimental binary interaction parameters. Based on this evidence, therefore, it appears reasonable to suggest potential application for our model in the assessment of fire and explosion hazards, and development of inherently safer designs for chemical process containing partially miscible mixtures.
SIE, FU-YUAN, and 謝福源. "The Disappearing Flash Point-Study and Creative Works of Ink Painting." Thesis, 2018. http://ndltd.ncl.edu.tw/handle/3h6skx.
Full text國立臺灣藝術大學
書畫藝術學系
106
Artists are quite sensitive in terms to reaction to the environment and convey their opinions toward the society through different forms of art works, expressing their care for the land or society, regardless through critical or implicit approach. In the paper, “The Disappearing Flash Point,” the author starts with self-identity and group identity and converts the author’s emotion of identity into printing. The work reflects the author’s comprehension on the surrounding of the society, where viewers appreciate the aesthetics conveyed from the work of the author and grow reflection for the society due to the sentiment toward the work. The composition of paper displays figures with text, supplemented by literature review. The paper collects different arguments of scholars and various fields of research as reference, probing into the internal idea of works to provide clarify on the creation context and accumulate subsequent strength of creation. The second chapter of the thesis describes the different aspects of identity, mainly exploring the cultural identity of Taiwan. The third chapter of the thesis used different artists as a reference to explore the relevance of self-works. The fourth chapter illustrates the context of self-creation. The fifth chapter concludes with creative experience, and outlines self-reflection and the outlooks of my creation. The author adopts “identity” in the internal idea of works as the focus and apply “self” and “local” as the main orientation of analysis for the various types of identity classification. The author adopts symbol, simplicity and decoration for modes of creation, in an attempt to present the pure and preserve the rhythmic approach for the work. With regards to the materials used for works, except for the “Only Me Series” featuring people, the “Island Series” use the objects of traditional flowers, decomposing and restructuring to interpret the care for the society through natural image. In this era of rapid circulation of information, the expression forms of contemporary arts become even more complicated and hence artists will need to maintain their core value in arts and capture the essence and attitude of advanced techniques in order to maintain their creation strength and grow.
Lu, Wen-Hung, and 呂文宏. "The Flash-Point Prediction for Partially Miscible Mixtures of Flammable Solvents." Thesis, 2006. http://ndltd.ncl.edu.tw/handle/68589709441672612835.
Full text中國醫藥大學
職業安全衛生學系碩士班
94
The flash point is one of the major safety data items specified in the typical material safety data sheet, but even those listed in a variety of MSDS sheet are, typically, only valid for a pure and specific compound composition. Flash point is also one of the major quantities used to characterize the fire and explosion hazard of liquids. The partially miscible mixtures are used in liquid-liquid extraction processes. This study presented a model for predicting the flash point of partially miscible of binary flammable solvent. The model was validated using the mixtures, methanol + octane, methanol + 2,2,4-trimethylpentane, ethanol + tetradecane, methanol + decane, acetone + decane and methanol + decane + acetone,respectively. In this study, the mathematical model was derived based on the theory of Vapor-Liquid Equilibrium, Liquid-Liquid Equilibrium and the theory of Le Chatelier’s rule. The Flash Point Analyzer, HFP 360 Pensky-Martens and HFP 362-Tag, manufactured by Walter Herzog GmbH (Germany) were used to measure the flash point of liquid solutions. The Flash Point Analyzers are operated according to the standard test method, ASTM D93 and ASTM D56. The results of this study revealed the model that predicts the flash point for binary partially-miscible mixtures of flammable solvent accurately and it including the flash point at the two margins of two liquid phases. These predictions could be applied to assess the fire and explosion hazard in real environment and safety designs for chemical processes.
CHEN, MAN-CHING, and 陳曼菁. "Study of the Non-flash Behavior of Aqueous-organic Solutions with Substance of Flash Point Being Greater Than 100℃." Thesis, 2019. http://ndltd.ncl.edu.tw/handle/xguwy4.
Full text國立高雄科技大學
環境與安全衛生工程系
107
While aqueous-organic mixtures or the leakage of flammable liquids are letting out in the process, it usually dilute water to eliminate fire and explosion hazard. However, this couldn’t be sure that flammability hazard of flammable liquids is eliminated. Therefore, flash point is become the important reference. In the study, the flash point test is to dilute flammable liquids by water, and explore binary aqueous – organic solution under the inerting effects of the lower flammability limit of the gas phase. We found it can not to flash in the test. And the trend is the same as study of Malcolm et al. In the study, we selected substances included water+1,2-ethanediol and water+caprolactam and water+1,4-butanediol and water+2-pyrrolidinone and water+1,2-propanedil, all of them have higher flash points and lower volatility. And we improved the deficiency of the flash point prediction model of Liaw et al., and it was used to predict the upper water level and the maximum flash point of aqueous–organic solution not to flash, and use the experimental data as proof. In 2014, the deficiency of the flash point prediction model of Liaw et al. was only applied in predicting lower flash point and higher volatility, so we improved the liquid phase composition of water and the activity coefficient of water at inerization point, let it apply in all binary aqueous–organic solutions. The results show that this model can successfully forecast the upper water level and the maximum flash point of aqueous–organic solution not to flash. Therefore, such a model can be used to determine whether the organic aqueous mixture is flammable or not.
Chiu, Chao-Yang, and 邱昭陽. "The flash-point prediction for ternary partially miscible mixtures of flammable solvents." Thesis, 2008. http://ndltd.ncl.edu.tw/handle/00925282848019707383.
Full text中國醫藥大學
職業安全衛生學系碩士班
96
Flash point is the most important variable used to characterize fire and explosion hazard of liquids. Even that has been listed in a variety of MSDS sheet, it is only valid for pure substance or specific compound composition. The partially miscible mixtures are used in liquid-liquid extraction process and heterogeneous distillation processs. This study intended to present a model for predicting the flash point of ternary partially miscible mixtures of flammable solvents. In this manuscript, the predicting model was derived based on the theory of Vapor-Liquid Equilibrium (VLE), Liquid-Liquid Equilibrium (LLE) and Le Chateliers’ rule. The experimental flash point data were used to validate this proposed model. The flash point analyzer, HFP 362-Tag, manufactured by Walter Herzog GmbH (Germany) was used to measure the flash point of studied mixtures, methanol + toluene + 2, 2, 4-trimethylpentane and acetone + methanol + n- decane. Our results reveal that immiscibility in the two liquid phase should not be ignored in the prediction of flash point. The predictive results of the proposed model could descryibe the experimental data well even it was applied to an immiscible solution. Based on this evidence, therefore, it appears reasonable to suggest potentiall application for our model in assessment of fire and explosion hazards, and development of inherently safer designs for chemical processs containing ternary partially miscible mixtures of flammable solvents.
Thomas, Derrick. "Critical Analysis and Review of Flash Points of High Molecular Weight Poly-functional C, H, N, O Compounds." Thesis, 2011. http://hdl.handle.net/1969.1/ETD-TAMU-2011-05-9289.
Full textPDF file replaced 4-20-2012 at request of Thesis Office.
Yang, Chieh-An, and 楊傑安. "The study of maximum flash-point behavior for ternary mixtures of flammable solvents." Thesis, 2011. http://ndltd.ncl.edu.tw/handle/16117747754079281658.
Full text中國醫藥大學
職業安全與衛生學系碩士班
99
Flash point is the major and important physical property to charactize the fire and explosion hazards of substances in the operatation, transportation and storage of flammable (or combustible) liquid. Different mixtures of flammable solvents appear different flash point behaviors. The study of binary mixtures exhibiting maximum flash point behavior had verified flash point of the mixture may be larger than those of the individual components and it decrease the risk of fire and explosion. However, the number of mixture solvents often larger than two components. Therefore the ternary flammable solvents maximum flash point behavior deserved to investigate. In this study, the flash point of ternary solutions were tested by the flash point tester(Walter Herzog GmbH HFP 362-Tag and HFP 360-Pensky Martens) .Three ternary solutions:phenol+cyclohexanol+cyclohexanone, phenol+acetophenone+1-propanol and phenol+cyclohexanol+benzyl alcohol were used to investigate maximum flash point behavior of ternary solutions. The experimental results were compared with the data of flash point prediction model. The change of flash point behavior at binary maximum flash point mixtures addition of a third component observed in this study. The results displayed three different ternary flash point behaviors, and provided more possible behaviors to classification. The study of negative deviation of multi-component had promoted and reduced the risk of flammable solvents.
Lin, Hsin-Hua, and 林欣樺. "The Flash Point Prediction Model for Organic Compounds Using Quantitative Structure Property Relationship Approach." Thesis, 2014. http://ndltd.ncl.edu.tw/handle/85199786319479513520.
Full text國立高雄第一科技大學
環境與安全衛生工程研究所
102
Flash point(FP) is the major index for categorizing the fire hazards of liquid compounds, and it is also one of the important characteristics used for assessing the fire and explosion hazards of a compound. However, due to limitations on experiments, the FP of compounds requires a certain amounts of sample, thus while the sample is of high-priced or is of toxic, there are substantial difficulties for conducting such experiments. Therefore, the prediction of flash points is an important safety subject. In this study, Using the quantitative structure property relationship (QSPR) approach built a model to predict the FP of organic compounds. This FP model is built from a set of 729 organic compounds, which are collected from the DIPPR 2012 database supported by American Institute of Chemical Engineer. The collected 729 organic compounds are randomly divided into a training set of 583 compounds and a testing set of 146 compounds and then Dragon 6 software and CODESSA Pro software are employed to calculate the corresponding molecular descriptors for each compounds. The stepwise regression method are then applied to choose molecular descriptors that are highly correlated with FP. This model has five molecular descriptors, the R2 value to be of 0.9055, the average error in percentage to be of 3.22% and predict the test data with Q2 = 0.8804, the average error in percentage to be of 3.33%.
王慈嫒. "A mathematical model for predicting the flash point of a solution with inorganic salt system." Thesis, 2004. http://ndltd.ncl.edu.tw/handle/74685463517618673684.
Full text中國醫藥大學
環境醫學研究所
92
The flash-point specification is one of the major safety data items specified in the typical material safety data sheet, but even those listed in a variety of MSDS sheets are, typically, only valid for a specific compound composition. In this study, a mathematical model which may used for predicting the flash point of a solution with inorganic salt system has been proposed and subsequently verified by experimentally-derived data. In this study, the mathematical model was derived based on the theory of vapor-liquid equilibrium and the theory of Le Chatelier’s rule. The Flash Point Analyzer, HFP 362-Tag, manufactured by Walter Herzog GmbH (Germany) was used to measure the flash point of liquid solutions associated with different compositions as tested. The Flash Point Analyzer is operated according to the standard test method, ASTM D56. The results reveal that this model is able to precisely predict the flash point over the entire composition range of acetone-methanol-inorganic salt system and aqueous-organ solution with inorganic salt system by way of utilizing the flash point data pertaining to the flammable components. The addition of inorganic-salt into a flammable solution is able to reduce the activity coefficient of the liquid solution, such that can increase the flash point of such a solution. Addition of inorganic salt into the flammable solutions would form a solution which is negative deviation from ideal solution, such that increase the flash point of flammable solutions. Such a result can be applied in the process safety design/operation.
CHEN, WAN-CHI, and 陳婉綺. "Predicting Flash Point and Auto-Ignition temperature of Liquid Organic Compounds using Quantitative Structure Activity Relationships Approach." Thesis, 2018. http://ndltd.ncl.edu.tw/handle/cy9nu8.
Full text國立高雄第一科技大學
環境與安全衛生工程系碩士班
106
Many flammable materials are used in industrial processes, so avoiding fire hazards is a critical issue for such processes. Liquid organic compounds are most commonly used chemical during process, we use flash point (FP) to determine what category of flammable liquid they are and decide the storage method through its category. Besides we also understand the combustion characteristics of the chemical through the auto-ignition temperature (AIT), and determine what correct specifications of explosion-proof electric equipment is provided for handling such flammable materials in order to effectively prevent the occurrence of fire and explosion. However, using experimental methods to evaluate physical properties of the chemicals is usually time consuming, costly, and it is even precarious for toxic or explosive chemicals. Therefore, REACH regulation encourages the use of cost effective alternatives, such as the Quantitative Structure Activity Relationships (QSAR) approach. Our study retrieved all data from DIPPR 801 database maintained by the American Institute of Chemical Engineers (AIChE), and selected only experimental data to avoid using predicted value to affect the model results. Eventually, 786 experimental data were used to establish a flash point prediction model with four descriptors. This model gives the goodness-of-fit performance (
Wu, Hsuan-Ta, and 吳弦達. "A mathematical model for predicting the flash point of ternary partially miscible mixtures of aqueous-organic system." Thesis, 2009. http://ndltd.ncl.edu.tw/handle/05865227148471033829.
Full text中國醫藥大學
職業安全衛生學系碩士班
97
Flash point is a variable used in characterizing fire and explosion hazard of liquids. The partially miscible mixtures are used in heterogeneous distillation process and liquid-liquid extraction process. The purpose of this study is to build a mathematical model to predict the flash point of the ternary partially miscible mixtures of aqueous-organic system. The proposed model was validated by use of water +ethanol + 1-butanol, water + ethanol + 2-butanol and water + 1-butanol + 2-butanol mixtures. The VLLE parameters were used to estimate the span of the tie lines and their flash point, and the VLE parameters were used to estimate the flash point in mutual solubility region. The flash point prediction model was verified by the experimental data to be able to estimate the range of the miscible and partially miscible phase during the simulation, as well as the constant flash point on each tie line.
Patel, Suhani Jitendra. "Integrating Safety Issues in Optimizing Solvent Selection and Process Design." Thesis, 2010. http://hdl.handle.net/1969.1/ETD-TAMU-2010-08-8248.
Full textNatalia, Daniele Dorighello Carareto. "Equilibre solide-liquide et point d'éclair de mélanges de corps gras." Thesis, 2014. http://www.theses.fr/2014PAUU3048/document.
Full textThe study on the physicochemical properties of fatty materials has acquired a growing importance, mainly due to the incentive of their use in energy and nutrition. The efficient production and use of fatty compounds requires a good knowledge of their properties and phase behavior that are necessary for development of processes, especially in production steps such as extraction and refining, but also during storage of the final products. Solid-liquid equilibrium data can be used to improve or propose new separation processes. Also the flash point is an important property that must be considered during storage, transportation and production of flammable compounds, such as biodiesel. This work aimed to study the solid-liquid equilibrium of binary mixtures consisting of fatty alcohols, fatty esters or fatty acids, and to evaluate the flash point of mixtures of ethyl esters, the major constituents of biodiesels, and ethanol, also present in biodiesel in residual levels. Flash points of ethyl esters, and also of the binary mixtures of ethyl esters with ethanol were determined experimentally. An empirical model for predicting the flash point of biodiesels as a function of composition and ethanol content was proposed. The solid-liquid phase diagrams of binary mixtures of fatty alcohol + fatty alcohol or fatty alcohols + fatty acid were determined experimentally by differential scanning calorimetry (DSC), using a linear heating rate, or by a stepscan DSC method, with the aim of investigating the occurrence of the eutectic, peritectic and metatectic reactions. X-ray diffraction and optical microscopy with temperature control techniques were applied to complement the understanding of the phase diagrams. The effect of pressure on the solid-liquid equilibrium was investigated for the binary mixtures of ethyl esters or fatty alcohols using an optical microscope coupled to a high pressure cell which allows the pressure increase up to 80 MPa. Margules 2 and 3-suffix and NRTL thermodynamic models were used for describing the liquidus line of the systems that presented peritectic point, and a predictive thermodynamic model was used to model the ESL function of pressure, which in both cases, gave a satisfactory fit compared to the experimental data
Yuan, Chengwu. "A new relative permeability model for compositional simulation of two and three phase flow." Thesis, 2010. http://hdl.handle.net/2152/ETD-UT-2010-12-2517.
Full texttext
Coelho, Bruna Patrícia Pinheiro Lopes. "Estudo de Otimização de Processo da Unidade de Produção de Fuelóleo Regenerado e Estudo do Potencial de Valorização do Mesmo." Master's thesis, 2020. http://hdl.handle.net/10362/108080.
Full textJONZA, JAMES M. "PHYSICAL STUDIES OF THERMOPLASTICS. I. MELTING TEMPERATURE MODIFICATIONS IN BISPHENOL A POLYCARBONATE. II. A MELTING POINT DEPRESSION STUDY OF POLYCARBONATE/POLYCAPROLACTONE BLENDS. III. THERMAL CONDUCTIVITY MEASUREMENTS OF ORIENTED POLYETHYLENES (DIFFUSIVITY, FLASH METHOD, MISCIBILITY, ANNEALING)." 1985. https://scholarworks.umass.edu/dissertations/AAI8602648.
Full textLeung, Ming-Kei, and 梁銘基. "First flush analysis of agricultural non-point source." Thesis, 2008. http://ndltd.ncl.edu.tw/handle/46935419760533270469.
Full text國立成功大學
環境工程學系碩博士班
96
Stormwater runoff was monitored on 6 separate agricultural watersheds, which were chosen to represent distinct types of farming and spreading chicken fields, along with various watershed characteristics. A total of 57 storm events were monitored to investigate the first flush phenomenon. There are two first flush phenomenon definition, one is concentration first flush(CFF), another is mass first flush(MFF). CFF may be defined as the initial period of stormwater runoff during which the concentration of pollutants is substantially higher than during later stages. MFF may be defined as the initial period of stormwater runoff during which the quality of pollutants throughout the majority of the pollution load. The magnitude of the first flush phenomenon was calculated using a method of data analysis which results in determining the dynamics event mean concentration ratio(REMC) and mass first flush ratio(MFFn). In addition, statistical and graphical correlation analysis of the REMC and MFFn with storm characteristics and environmental factors was made to determine if the first flush is related to site or storm characteristics. As the results, although the percentage of impervious area near zero, we can still be found strength to moderate concentration first flush phenomenon and moderate to mild mass first flush phenomenon in agricultural area. The results and analyses performed also indicates that the concentration first flush phenomenon of SS,COD and TP correlate well with total rainfall, total runoff and rain time but there are no correlation between the mass first flush phenomenon. No correlation was observed between the first flush phenomenon and area, slope and porosity. In this study, through cluster analysis proved that the first flush phenomenon in agricultural areas occurred mainly on non-soluble pollutants.
Tsai, Yi-Chen, and 蔡宜珍. "Prediction of Flash Points Using Quantitative Structure Property Relationship Approach." Thesis, 2011. http://ndltd.ncl.edu.tw/handle/93996806301460900631.
Full text中國醫藥大學
職業安全與衛生學系碩士班
99
Flash point (FP) is the primary property to classify flammable liquids for the purpose of assessing their fire and explosion hazards. Because of the advancement of technology in discovery or synthesis of new compounds, there is often a significant gap between the demand for such data and their availability. In this regard a reliable theoretical method to estimate the FP is indispensable. Although many works of predicting FP have been reported in literature, most methods require other physical properties to predict FP. However, the Quantitative Structure Activity Relationship (QSAR) approach could predict the desired property without using any other properties by experiment, and this is the reason why the REACH regulation adopt this approach as one of the an alternative methods while experimental data are unavailable. In this work, a QSPR studies are presented for predicting the FP of a data set of 230-organosilicon compounds and 1565-organic compounds, respectively. The collected 230 organosilicon compounds are randomly divided into a training set of 184 compounds and a testing set of 46 compounds. Then stepwise regression method is used to select the required molecular descriptors for predicting the FP of organosilicon compounds from 1538 candidate descriptors. Depending on the p-value for accepting a descriptor to enter the model, models with different number of descriptors are obtained. A 13-descriptor model and a 6-descriptor model are obtained with the p-value of 5 × 10-4 and 1 × 10-5, respectively. It is found that the 6-descriptor model could fit the training data with R2 = 0.8981 and predict the test data with Q2 = 0.8533 and the 13-descriptor model could fit the training data with R2 = 0.9293 and predict the test data with Q2 = 0.9245. On the other hand, the collected 1565 organic compounds are also randomly divided into a training set of 1254 compounds and a testing set of 311 compounds. The genetic algorithms and stepwise regression method are used to select the required molecular descriptors from 1785 candidate descriptors. A 10-descriptor model is obtained with the p-value of 5 × 10-16, and it is found that this model could fit the training data with R2 = 0.8958 and predict the test data with Q2 = 0.9210.