Academic literature on the topic 'Flat slab structure'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Flat slab structure.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Dissertations / Theses on the topic "Flat slab structure"

1

Bai, Jong-Wha. "Seismic fragility and retrofitting for a reinforced concrete flat-slab structure." Thesis, Texas A&M University, 2004. http://hdl.handle.net/1969.1/521.

Full text
Abstract:
The effectiveness of seismic retrofitting applied to enhance seismic performance was assessed for a five-story reinforced concrete (RC) flat-slab building structure in the central United States. In addition to this, an assessment of seismic fragility that relates the probability of exceeding a performance level to the earthquake intensity was conducted. The response of the structure was predicted using nonlinear static and dynamic analyses with synthetic ground motion records for the central U.S. region. In addition, two analytical approaches for nonlinear response analysis were compared. FEMA 356 (ASCE 2000) criteria were used to evaluate the seismic performance of the case study building. Two approaches of FEMA 356 were used for seismic evaluation: global-level and member-level using three performance levels (Immediate Occupancy, Life Safety and Collapse Prevention). In addition to these limit states, punching shear drift limits were also considered to establish an upper bound drift capacity limit for collapse prevention. Based on the seismic evaluation results, three possible retrofit techniques were applied to improve the seismic performance of the structure, including addition of shear walls, addition of RC column jackets, and confinement of the column plastic hinge zones using externally bonded steel plates. Finally, fragility relationships were developed for the existing and retrofitted structure using several performance levels. Fragility curves for the retrofitted structure were compared with those for the unretrofitted structure. For various performance levels to assess the fragility curves, FEMA global drift limits were compared with the drift limits based on the FEMA member-level criteria. In addition to this, performance levels which were based on additional quantitative limits were also considered and compared with FEMA drift limits.
APA, Harvard, Vancouver, ISO, and other styles
2

Wagner, Lara Suzanne. "Investigations of Upper Mantle Structure using Broadband Seismology." Diss., Tucson, Arizona : University of Arizona, 2005. http://etd.library.arizona.edu/etd/GetFileServlet?file=file:///data1/pdf/etd/azu%5Fetd%5F1204%5F1%5Fm.pdf&type=application/pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Porter, Ryan Charles. "Broadband Seismological Imaging of Flat-Slab Subduction and its Long-Term Impact on Lithospheric Structure and Processes." Diss., The University of Arizona, 2011. http://hdl.handle.net/10150/205469.

Full text
Abstract:
In subduction zones, the dip of the downgoing oceanic lithosphere has a profound impact on the nature and extent of deformation as well as the generation of melt. In ~10% of subduction zones, the downgoing slab assumes a low-angle, or horizontal geometry, referred to as flat-slab subduction. The focus of this work is to better understand both the driving forces and impacts of flat-slab subduction on the Earth's lithosphere and asthenosphere. This is accomplished by focusing on three areas impacted by flat-slab subduction. The first area is the Pampean region of central Argentina and Chile, a modern flat-slab subduction zone. In this region, we invert Rayleigh-wave-dispersion data to produce a 3D shear velocity model. The flat slab is visible within the upper mantle as a high-velocity body containing low-velocity pockets that dissipate inboard from the trench. We interpret these velocities in the context of slab hydration and argue that the subducting Nazca plate is initially hydrated at the trench and dewaters as it subducts. The second area is southern California, which was impacted by Laramide flat-slab subduction. In this area, we use receiver functions to locate and parameterize anisotropy within the crust. Results show a persistent NE-SW oriented layer of lower crustal anisotropy. We conclude that this layer consists of schists that were emplaced during Laramide flat-slab subduction and have remained largely intact since. The final component of this work is a study of the Colorado Plateau in which we use ambient-noise tomography and receiver functions to study lithospheric structure. Results show fast crust, a complicated Moho and intact Laramide features throughout the crust beneath the Colorado Plateau while slower crust with a sharp Moho is observed along its margins. Based on these observations, published tomographic data and the volcanic and uplift history of the region, we argue that delamination of the lower crust has occurred beneath the Marysvale volcanic field. This process was driven by the gravitational instability of a dense mafic root that formed during mid-Tertiary magmatism related to the rollback of the Farallon flat slab.
APA, Harvard, Vancouver, ISO, and other styles
4

Linkimer, Abarca Lepolt. "Lithospheric Structure of the Pampean Flat Slab (Latitude 30-33S) and Northern Costa Rica (Latitude 9-11N) Subduction Zones." Diss., The University of Arizona, 2011. http://hdl.handle.net/10150/202730.

Full text
Abstract:
The Pampean flat slab subduction in west-central Argentina (latitude 30-33S) and the steeply dipping Northern Costa Rica subduction zone (latitude 9-11N) show significant along-trench variations in both the subducting and overriding plates. This dissertation contains the results of three seismological studies using broadband instruments conducted in these subduction zones, with the aim of understanding the structure of the lithosphere and the correlation between the variability observed in the downgoing and the overriding plates. In the Costa Rica region, by analyzing teleseismic receiver functions we investigate the variability in the hydration state of the subducting Cocos Plate and the nature of three distinct crustal terranes within the overriding Caribbean Plate: the Nicoya and Chorotega terranes that display an oceanic character, and the Mesquito Terrane, which is more compatible with continental crust.In the Pampean region of Argentina, we apply a regional-scale double-difference tomography algorithm to earthquake data recorded by the SIEMBRA (2007-2009) and ESP (2008-2010) broadband seismic networks to obtain high-resolution images of the South America lithosphere. We find that most of the upper mantle has seismic properties consistent with a depleted lherzolite or harzburgite, with two anomalous regions above the flat slab: a higher Vp/Vs ratio anomaly consistent with up to 10% hydration of mantle peridotite and a localized lower Vp/Vs ratio anomaly consistent with orthopyroxene enrichment. In addition, we study the geometry and brittle deformation of the subducting Nazca Plate by determining high-quality earthquake locations, slab contours, and focal mechanisms. Our results suggest that the subduction of the incoming Juan Fernandez Ridge controls the slab geometry and that ridge buoyancy and slab pull are key factors in the deformation of the slab. The spatial distribution of the slab seismicity suggests variability in the hydration state of the subducting Nazca Plate and/or in strain due to slab bending. These observations support the hypothesis that the along-trench variability in bathymetric features and hydration state of the incoming plate has profound effects in the subducting slab geometry and the upper plate structure in both flat and steeply dipping subduction zones.
APA, Harvard, Vancouver, ISO, and other styles
5

Trygstad, Steinar. "Structural Behaviour of Post Tensioned Concrete Structures : Flat Slab. Slabs on Ground." Doctoral thesis, Norwegian University of Science and Technology, Faculty of Engineering Science and Technology, 2001. http://urn.kb.se/resolve?urn=urn:nbn:no:ntnu:diva-114.

Full text
Abstract:
<p>In this investigation strength and structural behaviour of prestressed concrete is studied with one full scale test of one flat slab, 16000 mm x 19000 mm, and three slabs on ground each 4000 mm x 4000 mm with thickness 150 mm. The flat slab was constructed and tested in Aalesund. This slab has nine circular columns as support, each with diameter 450 mm. Thickness of this test slab was 230 mm and there were two spans in each direction, 2 x 9000 mm in x-direction and 2 x 7500 mm in y-direction from centre to centre column. The slab was reinforced with twenty tendons in the middle column strip in y-direction and eight tendons in both outer column strips. In x-direction tendons were distributed with 340 mm distance. There were also ordinary reinforcement bars in the slab. Strain gauges were welded to this reinforcement, which together with the deflection measurements gives a good indication of deformation and strains in the structure.</p><p>At a live load of 6.5 kN/m<sup>2</sup> shear failure around the central column occurred: The shear capacity calculated after NS 3473 and EuroCode2 was passed with 58 and 69 %, respectively. Time dependent and non-linear FE analyses were performed with the program system DIANA. Although calculated and measured results partly agree well, the test show that this type of structure is complicated to analyse by non-linear FEM.</p><p>Prestressed slabs on ground have no tradition in Norway. In this test one reinforced and two prestressed slabs on ground were tested and compared to give a basis for a better solution for slabs on ground. This test was done in the laboratory at Norwegian University of Science and Technology in Trondheim. The first slab is reinforced with 8 mm bars in both directions distributed at a distance of 150 mm in top and bottom. Slab two and three are prestressed with 100 mm<sup>2</sup> tendons located in the middle of slab thickness, and distributed at a distance of 630 mm in slab two and 930 mm in slab three. Strain gauges were glued to the reinforcement in slab one and at top and bottom surface of all three slabs. In slab two and three there were four load cells on the tendons.</p><p>Each slab were loaded with three different load cases, in the centre of slab, at the edge and finally in the corner. This test shows that stiffness of sub-base is one of the most important parameters when calculating slabs on ground. Deflection and crack load level depends of this parameter. Since the finish of slabs on ground is important, it can be more interesting to find the load level when cracks start, than deflection for the slab. It is shown in this test that crack load level was higher in prestressed slabs than in reinforced slab. There was no crack in the top surface with load in the centre, but strain gauges in the bottom surface indicate that crack starts at a load of 28 kN in the reinforced slab, and 45 kN in the prestressed slabs. Load at the edge give a crack load of 30 kN in reinforced slab, 45 kN and 60 kN in prestressed slabs. The last load case gives crack load of 30 kN in reinforced slab, 107 kN and 75 kN in prestressed slabs. As for the flat slab, FE analyses were performed for all of the three slabs on ground, and analyses shows that a good understanding of parameters like stiffness of sub-base and tension softening model, is needed for correct result of the analyses.</p>
APA, Harvard, Vancouver, ISO, and other styles
6

Russell, Justin. "Progressive collapse of reinforced concrete flat slab structures." Thesis, University of Nottingham, 2015. http://eprints.nottingham.ac.uk/28991/.

Full text
Abstract:
In 1968 a relatively small gas exposition on the 18th floor of the Ronan Point tower building resulted in the partial collapse of the structure. This event highlighted that progress collapse may occur to structures under an accidental loading event. Other events, including the bombing of the Murrah federal building in 1993 in Oklahoma, have resulted in the common design requirement that a structure be capable of surviving the removal of a load bearing element. This approach, often referred to as the sudden column loss scenario, effectively ignores the cause of the damage and focuses on the structure’s response afterwards. The refinement of the analysis varies, with options to include the nonlinear and dynamic behaviours associated with extreme events, or to use simplified linear and static models with factors included to account for the full behaviour. Previous research into progressive collapse has highlighted that providing ductility in the connections, and avoiding brittle failures, is important in ensuring the structure maintains integrity after a column loss event. However, the majority of this work has been focused on the behaviour of steel and Reinforced Concrete (RC) frame structures. As flat slab construction is a popular method for many structures, due to the flexibility it offers for layouts and its low storey heights, it is an important to consider flat slab behaviour in more detail. Furthermore, slab elements behave differently to frame structures due to the Alternative Load Paths (ALPs) that can develop after a column loss via two-dimensional bending mechanisms. Additionally, punching shear failure is a known issue due to the thin section depths. This work addresses the issue of the response of RC flat slab structures after a sudden column loss. As previous case studies have demonstrated that brittle failures may lead to progressive collapse of such structures, a complete understanding of the response is required. The nonlinear behaviour of a slab structure, due to both material and geometric factors, is investigated to determine the additional capacity available beyond the usual design limits. Additionally, the dynamic factors involved, primarily due to inertial effects, are also considered. To achieve this, experimental and numerical studies were conducted. A series of 1/3 scale models of slab substructures were constructed to replicate column loss events. Two types of tests were conducted, a static push down test with a support removed and a sudden dynamic column removal case. Displacements, strains and support reactions were recorded throughout, along with cracking patterns. For the dynamic tests a high speed camera was used to obtain the deflection response in the short time period after removal and to observe the formation of cracks. Comparisons between the two cases allowed determination of the dynamic effects on the response of the system. The experimental programme was then replicated using a Finite Element (FE) model. The results taken from the experimental case were used to validate the material and modelling assumptions made during the numerical simulations. This validated model was finally used to investigate a wider range of variables and assess the response of typical structural arrangements, with particular focus on the nonlinear and dynamic factors involved after a sudden column loss. The experimental and numeral investigations demonstrated that after the loss of a column, flat slab structures can maintain integrity due to a change in the load paths away from the removal location. Although in some cases a large amount of flexural damage to the concrete and reinforcement occurred, such effects did not lead to complete failure. However, during the experimental programme some punching shear failures occurred, usually at the corner column locations. From the numerical analysis, shear forces of over twice the fully supported condition occurred as a result of removing a column, which may exceed the designed capacity. Comparisons between a static and dynamic analysis provides information into a suitable Dynamic Amplification Factor (DAF) for use with simplified modelling approaches. Based on the range of structures considered, the maximum increase in deflections as a result of a sudden removal was 1.62 times the static case, this is less than the commonly used factor of 2.0. Additionally, this factor reduces as the nonlinearity increases due to further damage, with a smallest DAF calculated at 1.39. This factor can be reduced further if the column is not removed instantaneously. Finally, the material strengthening effect, due to high strain rates, was considered with the conclusion that as such effects only make a limited increase in the capacity of the slab and may be conservatively ignored. In conclusion, RC flat slab structures are capable of resisting progressive collapse after the loss of a column. This is primarily due to their ability to develop ALPs. However, while flexural damage is usually fairly minimal, progressive punching shear failure is a critical design condition as it may result in a complete collapse. Furthermore, the inertial effects involved after a sudden removal can increase the damage sustained, although current design methods may be over conservative.
APA, Harvard, Vancouver, ISO, and other styles
7

Han, Ugur Burak. "Zdravotnické centrum." Master's thesis, Vysoké učení technické v Brně. Fakulta stavební, 2017. http://www.nusl.cz/ntk/nusl-265591.

Full text
Abstract:
The aim of this diploma thesis is to design a health care center in Brno. The building is located in Ivanovice/Brno. The building is ambulatory health care center with two doctor's offices for adult patients, one doctor's office for child patients and one dentist's clinic. Also, there is a pharmacy in the building. Reinforced concrete strip foundation and reinforced concrete basement peripheral walls are designed for the building. For above ground floors, ceramic masonry blocks are designed for structural load bearing frame. Green roof solution is chosen for the roof of the building.
APA, Harvard, Vancouver, ISO, and other styles
8

Van, der Merwe Johann Eduard. "Rocking shear wall foundations in regions of moderate seismicity." Thesis, Stellenbosch : University of Stellenbosch, 2009. http://hdl.handle.net/10019.1/1957.

Full text
Abstract:
Thesis (MScEng (Civil Engineering))--University of Stellenbosch, 2009.<br>ENGLISH ABSTRACT: In regions of moderate seismicity it has been shown that a suitable structural system is created when designing the shear wall with a plastic hinge zone at the lower part of the wall, with the shear walls resisting lateral loads and all other structural elements designed to resist gravity loads. A suitably stiff foundation is required for the assumption of plastic hinge zones to hold true. This foundation should have limited rotation and should remain elastic when lateral loads are applied to the structure. Ensuring a foundation with a greater capacity than the shear wall results in excessively large shear wall foundations being required in areas of moderate seismicity for buildings with no basement level. This study aims to investigate the feasibility of reducing the size of shear wall foundations in areas of moderate seismicity for buildings with no basement level. The investigation is aimed at allowing shear wall foundation rocking and taking into account the contribution of structural frames to the lateral stiffness of the structure. An example building was chosen to investigate this possibility. Firstly, lateral force-displacement capacities were determined for a shear wall and an internal reinforced concrete frame of this investigated building. Nonlinear momentrotation behaviour was determined for the wall foundation size that would traditionally be required as well as for six other smaller foundations. The above capacity curves against lateral loads were then used to compile a simplified model of the structural systems assumed to contribute to the lateral stiffness of the building. This simplified model therefore combined the effect of the shear wall, internal frame and wall foundation. Nonlinear time-history analyses were performed on this simplified model to investigate the dynamic response of the structure with different wall foundation sizes. By assessing response results on a global and local scale, it was observed that significantly smaller shear wall foundations are possible when allowing foundation rocking and taking into account the contribution of other structural elements to the lateral stiffness of the building.<br>AFRIKAANSE OPSOMMING: Daar is reeds getoon dat ʼn voldoende strukturele sisteem verkry word in gebiede van gematigde seismiese risiko indien ʼn skuifmuur ontwerp word met ʼn plastiese skarnier sone naby die ondersteuning van die muur. Skuifmure word dan ontwerp om weerstand te bied teen laterale kragte met alle ander strukturele elemente ontwerp om gravitasie kragte te weerstaan. Vir die aanname van plastiese skarnier sones om geldig te wees word ʼn fondasie met voldoende styfheid benodig. Só ʼn fondasie moet beperkte rotasie toelaat en moet elasties bly wanneer laterale kragte aan die struktuur aangewend word. ʼn Fondasie met ʼn groter kapasiteit as dié van die skuifmuur lei daartoe dat uitermate groot fondasies benodig word in gebiede van gematigde seismiese risiko vir geboue met geen kelder vlak. Hierdie studie is daarop gemik om die moontlikheid van kleiner skuifmuur fondasies te ondersoek vir geboue met geen kelder vlak in gebiede van gematigde seismiese risiko. Die ondersoek het ten doel om skuifmuur fondasie wieg aksie toe te laat en die bydrae van strukturele rame tot die laterale styfheid van die struktuur in ag te neem. Eerstens is die laterale krag-verplasing kapasiteit van ʼn skuifmuur en ʼn interne gewapende beton raam van die gekose gebou bepaal. Nie-lineêre moment-rotasie gedrag is bepaal vir die skuifmuur fondasie grootte wat tradisioneel benodig sou word asook vir ses ander kleiner fondasie grotes. Die bogenoemde kapasiteit kurwes is gebruik om ʼn vereenvoudigde model van die strukturele sisteme wat aanvaar word om laterale styfheid tot die gebou te verleen, op te stel. Hierdie vereenvoudigde model kombineer gevolglik die effek van die skuifmuur, interne raam en skuifmuur fondasie. Nie-lineêre tydgeskiedenis analises is uitgevoer op die vereenvoudigde model ten einde die dinamiese reaksie van die struktuur te ondersoek vir verskillende fondasie grotes. Resultate is beoordeel op ʼn globale en lokale vlak. Daar is waargeneem dat aansienlik kleiner skuifmuur fondasies moontlik is deur wieg aksie van die fondasie toe te laat en die bydrae van ander strukturele elemente tot die laterale styfheid van die gebou in ag te neem.
APA, Harvard, Vancouver, ISO, and other styles
9

Samadian, Fariborz. "Investigation of shear reinforcement for reinforced concrete flat slabs." Thesis, University of Westminster, 1997. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.362692.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Sudarsana, I. Ketut. "Punching shear in edge and corner column slab connections of flat plate structures." Thesis, University of Ottawa (Canada), 2001. http://hdl.handle.net/10393/6326.

Full text
Abstract:
The behavior and strength of edge and corner column slab connections of flat plate structures subjected to shear force only, moment only as well as combined shear force and moment were investigated. A two bay by two bay flat plate structure (nine columns) and eight isolated edge column slab connections were constructed and tested to failure. After the tests of the four edge column connections of the continuous slab were completed, the edge connections were repaired using two types of concretes (normal concrete and CAB expansive concrete) and tested to failure. Interaction diagrams between shear force and unbalanced moment at edge column slab connections based on building code provisions (ACI 318-99, CSA A23.3-94 and CEB-FIP MC90) and three alternative approaches (Regan's approach, the Truss Model and the Strip Model) proposed in the literature are examined using the results of the present experimental work. Interaction diagrams for corner connections calculated using Regan's approach and the building code provisions are compared with the experimental results. The shear strength of edge and corner connections is calculated according to ACI 318-99, CSA A23.3-85, BS8110-85, CEB-FIP MC90 and the alternative approaches of Regan, Sherif, Gardner, Elgabry, the Truss Model and the Strip Model. All alternative approach predictions of shear strength of edge connections, except Sheril's, are conservative. The average ratio of measured shear strength to calculated shear strength ranges from 0.90 to 1.30 with coefficients of variation (COV) ranging from 0.18 to 0.40. Gardner's approach, that considered a linear shear stress distribution as in ACI 318-99, with a critical shear section taken at the column perimeter or perimeter of loaded area gives the most conservative and the least scatter of the test results compared with the other proposed approaches. The measured shear strengths of the corner connections are compared to the calculated shear strengths based on the building code provisions and five alternative approaches available in the literature (i.e. Ingvarsson's, Regan's, Zaghlool's, Gardner's and Desayi's approach). On the basis of the present test results, the effects of load eccentricity (M/V) and reinforcement ratio (rho avg) on shear strength of edge column slab connections are investigated. The reduction in shear capacity of edge connections due to the increase in M/V ratios approximates a logarithmic function. The effect of the reinforcement ratio on the shear strength of the present tests on the edge and corner connections calculated using the North American codes is not obvious. However, tests by Zaghlool (1973) and Regan (1981) show that the shear strength increased with an increase in reinforcement ratio. The strength and stiffness of repaired edge connections were investigated using the four, previously failed, edge connections of the continuous slab specimen. Connections repaired using normal concrete can have similar strength and stiffness as the original connections. However, the connections repaired using the CAH expansive concrete exhibited less strength and stiffness compared to the original edge connections.
APA, Harvard, Vancouver, ISO, and other styles
More sources
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography