Dissertations / Theses on the topic 'Fracture fixation, internal'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the top 50 dissertations / theses for your research on the topic 'Fracture fixation, internal.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.
Shelton, Julia C. "Stability and failure of internal fixation systems." Thesis, Queen Mary, University of London, 1989. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.296780.
Full textRobb, Julie Lynn. "In vitro evaluation of veterinary and human suture anchors in metaphyseal bone of the canine tibia." Diss., Columbia, Mo. : University of Missouri-Columbia, 2006. http://hdl.handle.net/10355/5908.
Full text"August 2006" The entire dissertation/thesis text is included in the research.pdf file; the official abstract appears in the short.pdf file (which also appears in the research.pdf); a non-technical general description, or public abstract, appears in the public.pdf file. Vita. Includes bibliographical references.
Stoffel, Karl Kilian. "Modern concepts in plate osteosynthesis." University of Western Australia. School of Surgery and Pathology, 2007. http://theses.library.uwa.edu.au/adt-WU2007.0116.
Full textStankewich, Charles J. "The hip fracture epidemic : prevention and treatment strategies /." Thesis, Connect to this title online; UW restricted, 1998. http://hdl.handle.net/1773/8088.
Full textAngelini, Alessandro Janson. "Tratamento das fraturas com traço simples da diafise do femur, com tecnica minimamente invasiva e placa em onda." [s.n.], 2006. http://repositorio.unicamp.br/jspui/handle/REPOSIP/312286.
Full textTese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas
Made available in DSpace on 2018-08-08T02:22:20Z (GMT). No. of bitstreams: 1 Angelini_AlessandroJanson_D.pdf: 8473233 bytes, checksum: 3996290e908ef6f361b3a4bf25baf1d9 (MD5) Previous issue date: 2006
Resumo: A partir de resultados de estudos mecânicos com a placa em onda, demonstrando sua maior rigidez em montagens com algum tipo de contato cortical, surge este estudo com o objetivo de analisar o desempenho desse tipo de placa no tratamento das fraturas de traço simples da diáfise do fêmur. Foram incluídos, retrospectivamente, 57 pacientes, consecutivos, tratados com a placa em onda com técnica de osteossíntese biológica, com seguimento mínimo de um ano de pós-operatório. Obteve-se índice de consolidação de 94,74% (54 em 57 pacientes) em tempo médio de 12,88 semanas. Conclui-se que o método pode ser considerado uma alternativa às hastes intramedulares, com índices de consolidação semelhantes
Abstract: Mechanical studies with wave plates, were a higher rigidity was shown in models with cortical contact, suggested a study to analyze the use of wave plate in femoral simple shaft fractures. A consecutive series of 57 patients treated with wave plates and biological internal fixation, and a minimal follow up of 1 year after surgery. Healing occurred in 94,74% (54 of 57 patients) with an average of 12 weeks. In conclusion, this method could be considered an alternative to intramedullary nailing, with similar success rates
Doutorado
Cirurgia
Doutor em Cirurgia
Skoglund, Björn. "Following the mevalonate pathway to bone heal alley /." Linköping : Department of Clinical and Experimental Medicine, Materials in Medicine, Section of Orthopaedics and Sports Medicine, Faculty of Health Sciences, Linköping University, 2007. http://www.bibl.liu.se/liupubl/disp/disp2007/med1033s.pdf.
Full textHaynes, Rhona Claire. "Internal hip fracture fixation systems : analysis of implant performance for the optimisation of test protocols." Thesis, University of Bath, 1996. https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.320560.
Full textSantos, Saulo Ellery 1983. "Análise topográfica através de análise metalográfica de placa e parafuso do sistema 2,4mm com sistema de travamento em três diferentes quantidades de ciclos de autoclavagem." [s.n.], 2012. http://repositorio.unicamp.br/jspui/handle/REPOSIP/288782.
Full textTese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-20T05:38:06Z (GMT). No. of bitstreams: 1 Santos_SauloEllery_D.pdf: 17593176 bytes, checksum: 114d3bc8c68cd4b332a698a936817b96 (MD5) Previous issue date: 2012
Resumo: Sistemas de fixação interna estável são utilizados em cirurgia óssea, sejam elas de fraturas ou osteotomias programadas, podem ser submetido a múltiplos procedimentos de esterilização procedimentos antes da implantação em um ambiente de acolhimento. Durante a sua utilização eventualmente o cirurgião depara-se com intercorrências cirúrgicas como quebra da placa durante a dobragem ou quebra de parafusos durante sua inserção e isso de fato ocorre na prática clínica. O objetivo do autor neste estudo foi avaliar se o processo repetido de autoclavagens influencia nas características de dureza e microscópicas das placas e parafusos do sistema 2,4mm "locking". A amostra foi dividas em placas: grupo I (0) controle, grupo II submetido a 20 processos de autoclavagem e grupo III submetido a 60 processos de autoclavagem. Os parafusos foram divididos da mesma forma: grupo I (0), grupo II (20) e grupo III (60). Após o preparo do corpo de provas foram realizados os testes de dureza e avaliação em microscopia da microestrutura. Encontrou-se uma média de valores de dureza de 180,2; 183,8 e 171,8 Vickers respectivamente para os grupos I, II e III das placas (p=0,497) e os valores médios de 328,8; 340,8 e 355,3 Vickers respectivamente para os grupos I, II e III dos parafusos (p=0,283). Na análise microscópica tanto dos parafusos quanto das placas observou-se imagens em 500x que revelaram a microestrutura do material, com grânulos em conformações diferentes, de acordo com a margem analisada, observam-se ainda formação de maclas, principalmente na margem interna, o que pode ser decorrente de força de pressão/cisalhamento durante processo de usinagem, mas sem diferenças entre os grupos. Baseado nos resultados obtidos nas amostras estudadas, observou-se que o processo repetido de autoclavagens não alterou significativamente as características de dureza e microscópicas do material analisado
Abstract: Stable internal fixation systems are used in bone surgery, either fractures or osteotomies, It can be submitted to multiple procedures sterilization procedures before implantation. During its use eventually the surgeon is confronted with surgical complications such as rupture of the plate during bending or breakage of screws during insertion, and this in fact occurs in clinical practice. The aim of study was to evaluate if the repeated autoclaving influences the characteristics of hardness and microscopic of plates and screws of 2.4 mm system "locking". The sample was divided into plates: group I (0) control, group II was subjected to 20 sterilization processes and group III underwent 60 procedures for autoclaving. The screws were divided equally: group I (0), group II (20) and group III (60). After preparing the sample, and were carried out hardness testing and evaluation in the microscopy of microstructure. We found a mean hardness value of 180.2, 183.8 and 171.8 Vickers respectively for the groups I, II and III of the plates (p = 0.497) and mean values of 328.8, 340.8 and 355.3 Vickers respectively for the groups I, II and III of the screws (p = 0.283). Microscopic analyzes of both screws and the plates was observed images 500x revealed that the microstructure of the material, with granules in different conformations in accordance with the margin analyzed, there are still forming twinned, especially in the inset, which may be due to pressure force / shear during the machining process, but no differences between groups was observed. Based on the results obtained in all samples, it was observed that the repeated autoclaving does not significantly alter the characteristics of the material hardness and microscopic examination
Doutorado
Cirurgia e Traumatologia Buco-Maxilo-Faciais
Doutor em Clínica Odontológica
Johansson, Torsten. "Displaced Femoral Neck Fractures : A prospective randomized study of clinical outcome, nutrition and costs." Doctoral thesis, Linköping : Univ, 2002. http://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-5233.
Full textWall, Gert. "Studies on segmental displacement after Le Fort I and bilateral sagittal split osteotomies stabilized by rigid internal fixation." Malmö : Dept. of Oral Surgery and Oral Medicine, School of Dentistry, University of Malmö, 2001. http://catalog.hathitrust.org/api/volumes/oclc/47627005.html.
Full textBlomfeldt, Richard. "Surgical treatment of patients with displaced femoral neck fractures : aspects on outcome and selection criteria /." Stockholm, 2006. http://diss.kib.ki.se/2006/91-7140-801-0/.
Full textRibeiro, Júnior Paulo Domingos [UNESP]. "Avaliação in vitro do uso de uma miniplaca convencional e locking, de 4 e 7 furos, para tratamento das fraturas de ângulo mandibular." Universidade Estadual Paulista (UNESP), 2008. http://hdl.handle.net/11449/101039.
Full textConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Este estudo avaliou in vitro a influência do tipo de miniplaca (convencional ou locking) e do número de parafusos instalados no segmento ósseo distal e proximal para a promoção da estabilidade óssea e resistência da osteossínteses pelo método Champy, utilizada para o tratamento de fraturas de ângulo mandibular. Sessenta hemi-mandíbulas de poliuretano, com consistência similar ao osso mandibular, foram divididas em 4 grupos (n=15) e seccionadas na região de ângulo mandibular simulando uma fratura. Os segmentos ósseos foram fixados por diferentes tipos de miniplacas usando sistema 2.0- mm e parafusos monocorticais de 2.0 x 6.0mm. Nos grupos 1 e 2, dois parafusos convencionais (G1) ou locking (G2) foram instalados em cada segmento ósseo usando respectivamente miniplacas retas convencionais e locking; Nos grupos 3 e 4, três parafusos convencionais (G3) ou locking (G4) foram instados no segmento ósseo proximal e quatro parafusos convencionais (G3) ou locking (G4) foram instalados no segmento distal, usando uma miniplaca convencional (G3) e locking (G4) de sete furos, reta. As hemi-mandíbulas foram submetidas a um teste de compressão utilizando uma máquina universal de ensaio INSTRON até que houvesse um distanciamento entre os segmentos ósseos de 4 mm, seja no sentido horizontal ou vertical. Os dados registrados foram submetidos à avaliação estatística pelo método ANOVA e teste de Tukey utilizando um nível de significância de 1%. As miniplacas locking ofereceram maior resistência ao teste de compressão do que as miniplacas convencionais (p<0.01). Porém, não existiu diferença entre o uso de miniplacas de 7 ou 4 furos (p>0.01). Apesar de não estatisticamente significante os resultados numéricos sugeriram que as miniplacas locking longas oferecem maior resistência ao teste de compressão que as miniplacas locking curtas.
This study evaluated in vitro the influence of the type of miniplate (conventional or locking) and the number of screws installed in the proximal and distal segments on the stability and resistance of Champy’s osteosynthesis in mandibular angle fractures. Sixty polyurethane hemimandibles with bone-like consistency were randomly assigned to 4 groups (n=15) and sectioned in the mandibular angle region to simulate fracture. The bone segments were fixed by different osteosynthesis methods using 2.0-mm miniplates and 2.0 x 6 mm monocortical screws: Groups 1 and 2- Two conventional (G1) or locking (G2) screws were installed in each bone segment using either a conventional (G1) or a locking (G2) straight miniplate; Groups 3 and 4- Three conventional (G3) or locking (G4) screws were installed in the proximal segment and four conventional (G3) or locking (G4) screws were installed in the distal segment using a either a conventional (G3) or a locking (G4) 7-hole straight miniplate. The hemimandibles were loaded in compressive strength in an Instron machine until a 4-mm displacement occurred between the segments either vertically or horizontally. Data were analyzed statistically by ANOVA and Tukey’s test at 1% significance level. The locking plate/screw systems provided significantly greater resistance to displacement under compressive load than the conventional plate/screw systems (p<0.01). However, no statistically significant difference was found between 7-hole and 4-hole miniplates (p>0.01). In conclusion, the locking miniplates offered more resistance than conventional miniplates and long locking miniplates provided greater (number results) bone stability compared to short ones.
Érnica, Natasha Magro [UNESP]. "Tratamento cirúrgico intrabucal das fraturas de ângulo mandibular com uma miniplaca de titânio: estudo clínico e radiográfico." Universidade Estadual Paulista (UNESP), 2002. http://hdl.handle.net/11449/88954.
Full textO objetivo deste estudo foi avaliar, clínica e radiograficamente, pacientes com fraturas de ângulo mandibular tratadas por meio de redução cirúrgica e fixação com uma miniplaca de titânio de 2,0 mm de espessura, associada a parafusos monocorticais. Foram avaliados retrospectivamente 21 pacientes, com 22 fraturas fraturas de ângulo mandibular, tratados pela equipe de Cirurgia e Traumatologia Buco-Maxilo- Facial da Faculdade de Odontologia de Araçatuba - UNESP, na Santa Casa de Misericórdia de Araçatuba e Santa Casa de Misericórdia de Birigüi, Estado de São Paulo, no período de julho de 1999 a fevereiro de 2002. Todas as fraturas de ângulo mandibular avaliadas foram fixadas utilizando uma miniplaca de 2,0 mm de espessura, com parafusos monocorticais, disposta ao longo da linha oblíqua mandibular, sem utilização de fixação intermaxilar no pós-operatório. O tempo de proservação variou de 6 a 44 meses, com média de 15 meses e 1 dia. Foi observada, para essas fraturas, incidência de 14,3% de complicações pós-operatórias, sendo 4,8% infecção, 4,8% má-oclusão e 4,8% distúrbios sensoriais - hiperestesia no local de retenção da miniplaca. Dentre as complicações, a única que exigiu nova intervenção cirúrgica sob anestesia local foi a infecção pós-operatória. Assim, pode-se concluir que o método empregado foi clinicamente adequado para o tratamento de fraturas simples de ângulo mandibular, a presença de apenas uma miniplaca não interferiu no índice de complicações pós-operatórias, e o método evitou a fixação intermaxilar pós- operatória.
The aim of this study was to evaluate clinical and radiographic, mandibular angle fractures treated by open reduction and one single 2.0 mm titanium miniplate fixation associated with monocortical screws. The author retrospectively evaluated 21 patients, with 22 mandibular angle fractures, operated by Oral and Maxillofacial Surgery Division from the Dental School of Araçatuba, UNESP, Brazil, during the period from July 1999 to February 2002. All mandibular angle fractures studied were treated by open reduction and internal fixation with one single 2.0 mm miniplate, positioned along the mandible oblique line, without post-operative intermaxilar fixation. Follow-up ranged from 6 to 44 months, with a mean of 15 months and 1 day. Complications occurred in 3 patients (14,3%). One patient (4,8%) presented post-operative infection, one (4,8%) malocclusion, and one (4,8%) sensory disturbance - hyperesthesia in the region of the retained miniplate. The only case requiring a further surgical intervention under general anesthesia was the infection case. Thus, results allowed to conclude that the fixation method was suitable for treatment of simple mandibular angle fractures, the presence of only one single miniplate did not interfere on the post-operative complication rate, and the method avoided post-operative intermaxilar fixation.
Demko, Jennifer Lynn. "Axial pull-out strength of 3.5 cortical and 4.0 cancellous bone screws placed in canine proximal tibias using manual and power tapping." Master's thesis, Mississippi State : Mississippi State University, 2008. http://library.msstate.edu/etd/show.asp?etd=etd-03312008-205137.
Full textRibeiro, Júnior Paulo Domingos. "Avaliação in vitro do uso de uma miniplaca convencional e locking, de 4 e 7 furos, para tratamento das fraturas de ângulo mandibular /." Araçatuba : [s.n.], 2008. http://hdl.handle.net/11449/101039.
Full textBanca: Wilson Roberto Poi
Banca: Celso Koogi Sonoda
Banca: Maria Papageorge
Banca: Kalpakam Shastri
Resumo: Este estudo avaliou in vitro a influência do tipo de miniplaca (convencional ou locking) e do número de parafusos instalados no segmento ósseo distal e proximal para a promoção da estabilidade óssea e resistência da osteossínteses pelo método Champy, utilizada para o tratamento de fraturas de ângulo mandibular. Sessenta hemi-mandíbulas de poliuretano, com consistência similar ao osso mandibular, foram divididas em 4 grupos (n=15) e seccionadas na região de ângulo mandibular simulando uma fratura. Os segmentos ósseos foram fixados por diferentes tipos de miniplacas usando sistema 2.0- mm e parafusos monocorticais de 2.0 x 6.0mm. Nos grupos 1 e 2, dois parafusos convencionais (G1) ou locking (G2) foram instalados em cada segmento ósseo usando respectivamente miniplacas retas convencionais e locking; Nos grupos 3 e 4, três parafusos convencionais (G3) ou locking (G4) foram instados no segmento ósseo proximal e quatro parafusos convencionais (G3) ou locking (G4) foram instalados no segmento distal, usando uma miniplaca convencional (G3) e locking (G4) de sete furos, reta. As hemi-mandíbulas foram submetidas a um teste de compressão utilizando uma máquina universal de ensaio INSTRON até que houvesse um distanciamento entre os segmentos ósseos de 4 mm, seja no sentido horizontal ou vertical. Os dados registrados foram submetidos à avaliação estatística pelo método ANOVA e teste de Tukey utilizando um nível de significância de 1%. As miniplacas locking ofereceram maior resistência ao teste de compressão do que as miniplacas convencionais (p<0.01). Porém, não existiu diferença entre o uso de miniplacas de 7 ou 4 furos (p>0.01). Apesar de não estatisticamente significante os resultados numéricos sugeriram que as miniplacas locking longas oferecem maior resistência ao teste de compressão que as miniplacas locking curtas.
Abstract: This study evaluated in vitro the influence of the type of miniplate (conventional or locking) and the number of screws installed in the proximal and distal segments on the stability and resistance of Champy's osteosynthesis in mandibular angle fractures. Sixty polyurethane hemimandibles with bone-like consistency were randomly assigned to 4 groups (n=15) and sectioned in the mandibular angle region to simulate fracture. The bone segments were fixed by different osteosynthesis methods using 2.0-mm miniplates and 2.0 x 6 mm monocortical screws: Groups 1 and 2- Two conventional (G1) or locking (G2) screws were installed in each bone segment using either a conventional (G1) or a locking (G2) straight miniplate; Groups 3 and 4- Three conventional (G3) or locking (G4) screws were installed in the proximal segment and four conventional (G3) or locking (G4) screws were installed in the distal segment using a either a conventional (G3) or a locking (G4) 7-hole straight miniplate. The hemimandibles were loaded in compressive strength in an Instron machine until a 4-mm displacement occurred between the segments either vertically or horizontally. Data were analyzed statistically by ANOVA and Tukey's test at 1% significance level. The locking plate/screw systems provided significantly greater resistance to displacement under compressive load than the conventional plate/screw systems (p<0.01). However, no statistically significant difference was found between 7-hole and 4-hole miniplates (p>0.01). In conclusion, the locking miniplates offered more resistance than conventional miniplates and long locking miniplates provided greater (number results) bone stability compared to short ones.
Doutor
Kayatt, Fernando Esgaib [UNESP]. "Avaliação do seio maxilar após fratura do complexo zigomático-maxilar tratado com fixação interna rígida em dois pontos: estudo radiográfico em humanos." Universidade Estadual Paulista (UNESP), 2002. http://hdl.handle.net/11449/88953.
Full textO complexo zigomático maxilar é a segunda área da face mais atingida por injúrias, superada apenas pelos ossos nasais. É elemento essencial na configuração da face, uma vez que é a principal estrutura formadora do terço médio facial. É importante na biomecânica, está situado entre o víscero e o neurocrânio, desempenha papel fundamental na absorção e escoamento das forças de mastigação através dos pilares de reforço e sustentação. Nesse contesto encontra-se o seio maxilar cujas funções destacamse: diminuição do peso do crânio; auxiliar a ressonância da voz, a produção e a armazenagem do muco, a umidificação do ar inspirado, a manutenção do aquecimento da fossa nasal, servir como acessório do olfato, definir o contorno facial, entre outras. Avaliamos, através de radiografias PA de Waters, 40 pacientes, sendo 20 pacientes traumatizados nessa região, que foram submetidos à fixação interna rígida em dois pontos e 20 pacientes hígidos, comparando a projeção da imagem do contorno do seio maxilar. Estas avaliações foram realizadas em um período pós-operatório superior a 6 meses. Após análise dos resultados, concluímos que baseado nos achados radiográficos e nos valores de áreas dos seios maxilares, a fixação interna rígida em dois pontos mostrou-se eficaz no tratamento das fraturas não cominutivas do complexo zigomáticomaxilar.
The ZMC is the second facial area most affected by injuries, only surpassed by nasal bones fractures. It’s an essential element in facial configuration because it’s the middle third facial main structure. It’s important biomechanical being situated between the visceral and neurocranium, develop fundamental absorving and draining of the chewing forces job, across the sustaintation and strenghten pillars. Inside this complex the maxillary sinus and its functions are: to reduce head weight, to help voice ressonance, to produce and to store mucus, to umidificate the breathen air, to maintain the nasal fossa warm, olfative accessory and to define the facial contour and others. The research was performed through PA Waters radiography; 40 patients: 20 traumatizated patients in this region, submitted to the two points IRF and 20 health patients were evaluated, comparing the image projection of the maxillary sinus and observating the stability of this kind of fixation. These evaluations were made in post-operative periods, latter 6 months. After result analysis we concluded, based radiography evidence and measurement maxillary sinus area, the two points IRF are efficient on treatment of ZMC fractures not cominutive.
Kayatt, Fernando Esgaib. "Avaliação do seio maxilar após fratura do complexo zigomático-maxilar tratado com fixação interna rígida em dois pontos : estudo radiográfico em humanos /." Araçatuba : [s.n.], 2002. http://hdl.handle.net/11449/88953.
Full textResumo: O complexo zigomático maxilar é a segunda área da face mais atingida por injúrias, superada apenas pelos ossos nasais. É elemento essencial na configuração da face, uma vez que é a principal estrutura formadora do terço médio facial. É importante na biomecânica, está situado entre o víscero e o neurocrânio, desempenha papel fundamental na absorção e escoamento das forças de mastigação através dos pilares de reforço e sustentação. Nesse contesto encontra-se o seio maxilar cujas funções destacamse: diminuição do peso do crânio; auxiliar a ressonância da voz, a produção e a armazenagem do muco, a umidificação do ar inspirado, a manutenção do aquecimento da fossa nasal, servir como acessório do olfato, definir o contorno facial, entre outras. Avaliamos, através de radiografias PA de Waters, 40 pacientes, sendo 20 pacientes traumatizados nessa região, que foram submetidos à fixação interna rígida em dois pontos e 20 pacientes hígidos, comparando a projeção da imagem do contorno do seio maxilar. Estas avaliações foram realizadas em um período pós-operatório superior a 6 meses. Após análise dos resultados, concluímos que baseado nos achados radiográficos e nos valores de áreas dos seios maxilares, a fixação interna rígida em dois pontos mostrou-se eficaz no tratamento das fraturas não cominutivas do complexo zigomáticomaxilar.
Abstract: The ZMC is the second facial area most affected by injuries, only surpassed by nasal bones fractures. It's an essential element in facial configuration because it's the middle third facial main structure. It's important biomechanical being situated between the visceral and neurocranium, develop fundamental absorving and draining of the chewing forces job, across the sustaintation and strenghten pillars. Inside this complex the maxillary sinus and its functions are: to reduce head weight, to help voice ressonance, to produce and to store mucus, to umidificate the breathen air, to maintain the nasal fossa warm, olfative accessory and to define the facial contour and others. The research was performed through PA Waters radiography; 40 patients: 20 traumatizated patients in this region, submitted to the two points IRF and 20 health patients were evaluated, comparing the image projection of the maxillary sinus and observating the stability of this kind of fixation. These evaluations were made in post-operative periods, latter 6 months. After result analysis we concluded, based radiography evidence and measurement maxillary sinus area, the two points IRF are efficient on treatment of ZMC fractures not cominutive.
Mestre
Gaiarsa, Guilherme Pelosini. "Estudo comparativo entre as osteossínteses de tornozelo com implantes convencionais e bioabsorvíveis." Universidade de São Paulo, 2013. http://www.teses.usp.br/teses/disponiveis/5/5140/tde-26032013-111341/.
Full textThe current gold standard fixation system for surgical ankle fractures are the metallic implants, steel or titanium made. Resorbable implants have been developed to avoid stress shielding and a new surgery for implant removal, common with metal implants. Use of resorbable implants is well documented in the literature for a range of craniofacial fractures, with good results. The purpose of this study was to compare the outcome of ankle fractures using biodegradable and metal plates. Patients were randomly and prospectively treated with resorbable or metal fixation system. Post-operatively, the ankle was immobilized with a plaster cast for 1 week, removable cast for other 4 weeks. Half and full weight bearing were allowed at weeks 3 and 6. nineteen patients were followed for 9 months. Functional recovery was similar in both groups at 6 and 9 months, three patients in metal group complained implant-related problems, and had their implants removed, and one in resorbable had an acute dehiscence, solved with surgical debridement and closure. At 6 and 9 months, the AOFAS score was applied for all patients. The functional results were similar in both groups. Implant removal was necessary in three patients from the metallic group. The resorbable plate provided qualitatively similar fracture healing results as the metal plate
Johnson, Aaron Joseph. "Humeral fracture fixation techniques a FEA comparison of locing [i.e. locking] and compression techniques with cadaveric pullout comparison of cortical compression and internal locking screws /." College Park, Md.: University of Maryland, 2007. http://hdl.handle.net/1903/7367.
Full textThesis research directed by: Dept. of Mechanical Engineering. Title from t.p. of PDF. Includes bibliographical references. Published by UMI Dissertation Services, Ann Arbor, Mich. Also available in paper.
Pinto, Clarice Maia Soares de Alcântara 1986. "Metallographic, gas and energy dispersive x-ray analyses of osteosynthesis plates and screws and dental implants removed from patients with clinical indication = Análise metalográfica, de gases e espectrometria por energia dispersiva de raios-x de placas e parafusos para osteossíntese e de implantes dentários removidos de pacientes com indicação clínica." [s.n.], 2013. http://repositorio.unicamp.br/jspui/handle/REPOSIP/287888.
Full textDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-24T07:46:17Z (GMT). No. of bitstreams: 1 Pinto_ClariceMaiaSoaresdeAlcantara_M.pdf: 1620980 bytes, checksum: 1e0ec8457d9b0d64bf078cf763f07f37 (MD5) Previous issue date: 2013
Resumo: O objetivo do presente trabalho foi avaliar a microestrutura e a composição química dos implantes dentários, placas e parafusos para osteossíntese removidos de pacientes em casos com indicação clínica. No trabalho 1, foram realizadas análises metalográfica, de gases e de espectrometria por energia dispersiva de raios-X de placas e parafusos de titânio utilizados para osteossíntese e removidos de 30 pacientes. Os prontuários destes pacientes foram avaliados para obtenção de dados referentes à idade, gênero, procedimento cirúrgico que havia motivado a inserção das placas e parafusos para osteossíntese, a razão clínica para remoção e o tempo de permanência destes dispositivos in situ. Quarenta e oito placas e 238 parafusos foram removidos no total. Infecção consistiu na principal causa para remoção destes dispositivos, correspondendo a 43.3% dos casos. O principal sítio do qual as placas e os parafusos foram removidos foi a mandíbula, equivalendo a 66.6% dos casos. Todas as placas e parafusos analisados estavam dentro das normas F67 e F136 da ASTM (American Society for Testing and Materials) de acordo com a análise metalográfica e a espectrometria por energia dispersiva de raios-X. Na análise de gases, cinco amostras apresentaram valores acima do regulamentado pela ASTM para os elementos Hidrogênio e/ou Oxigênio. A partir do estudo, pôde-se concluir que as propriedades físicas e químicas das amostras não estavam associadas à condição clínica que ocasionou a remoção destes dispositivos e que o tempo de permanência destes implantes in situ não determinou alterações em suas propriedades. No trabalho 2, foram realizadas análises metalográfica e de espectrometria por energia dispersiva de raios-X para avaliação de 38 implantes dentários de titânio removidos de 29 pacientes com indicação clínica. Os prontuários destes pacientes foram avaliados para obtenção de dados referentes à idade, gênero, razão clinica para remoção e tempo de permanência dos implantes. Falta de osseointegração sem sintomatologia ou sinais de infecção associados foi a principal causa para falha dos implantes, correspondendo a 55.1% dos casos. A maxila foi o sítio de falha dos implantes dentários em dezessete pacientes (58.6%) enquanto doze pacientes (41.4%) apresentaram falha de implantes instalados na mandíbula. Todos os implantes analisados eram constituídos de titânio comercialmente puro e apresentaram-se dentro da norma F67 da ASTM. A partir do estudo, pôde-se concluir que as propriedades físicas e químicas dos implantes dentários analisados não estavam associadas ao insucesso no tratamento e à falha destes dispositivos
Abstract: The aim of this study was to evaluate the microstructure and chemical composition of dental implants, bone plates and screws removed from patients in cases of clinical indication. In the first study, metallographic, gas and energy dispersive X-ray analyses were performed to evaluate osteosynthesis plates and screws retrieved from 30 patients. The medical records of these patients were evaluated to obtain data regarding age, gender, surgical procedure that had motivated the insertion of osteosynthesis plates and screws, the reason for removal and the period of time of these devices in situ. Forty-eight plates and 238 screws were removed in total. Infection was the main reason for these devices removal, representing 43.3% of cases. Mandible was the main site for plates and screws removal, corresponding to 66.6% of cases. All plates and screws analyzed were within the specifications F67 and F136 of ASTM (American Society for Testing and Materials) according metallographic and energy dispersive X-ray analyses. In gas analysis, five samples had hydrogen and/or oxygen values above the regulated by ASTM. From the study, it was concluded that the physical and chemical properties of the samples were not associated with the clinical condition that caused the removal of these devices, and retention time of these implants did not determine changes in their properties. In the second study, metallographic and energy dispersive X-ray analyses were performed for evaluation of 38 dental implants removed from 29 patients with clinical indication. Medical records of these patients were evaluated to obtain data regarding age, gender, reason for removal and period of time in situ. Lack of osseointegration without symptomatology or signs of infection was the main reason for dental implants failure, corresponding to 55.1% of cases. Maxilla was the site of implants failure in seventeen patients (58.6%) while twelve patients (41.4%) had failure of dental implants installed in mandible. All dental implants analyzed were manufactured of commercially pure titanium and were within the ASTM F67 specification. From the study, it was concluded that physical and chemical properties of dental implants analyzed were not associated with failure of these devices.
Mestrado
Cirurgia e Traumatologia Buco-Maxilo-Faciais
Mestra em Clínica Odontológica
Queiroz, Christiano Sampaio. "Estudo comparativo entre a fixação interna e a fixação in-termaxilar no reparo ósseo de fraturas mandibulares por meio de imagem radiográfica digital." Programa de Pós- Graduação em Odontologia da UFBA, 2007. http://www.repositorio.ufba.br/ri/handle/ri/10520.
Full textSubmitted by Suelen Reis (suziy.ellen@gmail.com) on 2013-04-23T15:07:00Z No. of bitstreams: 9 Dissertação Christiano Queiroz9.pdf: 175521 bytes, checksum: 51b44b81e110bb6c6dc002a13333f327 (MD5) Dissertação Christiano Queiroz8.pdf: 155984 bytes, checksum: f5c4a46d60e77b0718848fab96f85373 (MD5) Dissertação Christiano Queiroz7.pdf: 1461220 bytes, checksum: 621ab609ba799dba10e909031c8cccc9 (MD5) Dissertação Christiano Queiroz6.pdf: 1474051 bytes, checksum: c8186f90fc20cb7c9db3cd0f92c1c773 (MD5) Dissertação Christiano Queiroz5.pdf: 860472 bytes, checksum: 1e0bb30340dc455ba5886425887a6b73 (MD5) Dissertação Christiano Queiroz4.pdf: 145777 bytes, checksum: 002d8ab1dd097ffae4cef5a4ac414724 (MD5) Dissertação Christiano Queiroz3.pdf: 175599 bytes, checksum: 87cbe8be31bd0209f31d80cfd461be9c (MD5) Dissertação Christiano Queiroz2.pdf: 159009 bytes, checksum: 8b8dae41086fcfc427e8a67780010cc4 (MD5) Dissertação Christiano Queiroz1.pdf: 195113 bytes, checksum: 4c0bba61fcc22b702a39d4a21f319e93 (MD5)
Approved for entry into archive by Rodrigo Meirelles(rodrigomei@ufba.br) on 2013-05-08T11:49:28Z (GMT) No. of bitstreams: 9 Dissertação Christiano Queiroz9.pdf: 175521 bytes, checksum: 51b44b81e110bb6c6dc002a13333f327 (MD5) Dissertação Christiano Queiroz8.pdf: 155984 bytes, checksum: f5c4a46d60e77b0718848fab96f85373 (MD5) Dissertação Christiano Queiroz7.pdf: 1461220 bytes, checksum: 621ab609ba799dba10e909031c8cccc9 (MD5) Dissertação Christiano Queiroz6.pdf: 1474051 bytes, checksum: c8186f90fc20cb7c9db3cd0f92c1c773 (MD5) Dissertação Christiano Queiroz5.pdf: 860472 bytes, checksum: 1e0bb30340dc455ba5886425887a6b73 (MD5) Dissertação Christiano Queiroz4.pdf: 145777 bytes, checksum: 002d8ab1dd097ffae4cef5a4ac414724 (MD5) Dissertação Christiano Queiroz3.pdf: 175599 bytes, checksum: 87cbe8be31bd0209f31d80cfd461be9c (MD5) Dissertação Christiano Queiroz2.pdf: 159009 bytes, checksum: 8b8dae41086fcfc427e8a67780010cc4 (MD5) Dissertação Christiano Queiroz1.pdf: 195113 bytes, checksum: 4c0bba61fcc22b702a39d4a21f319e93 (MD5)
Made available in DSpace on 2013-05-08T11:49:28Z (GMT). No. of bitstreams: 9 Dissertação Christiano Queiroz9.pdf: 175521 bytes, checksum: 51b44b81e110bb6c6dc002a13333f327 (MD5) Dissertação Christiano Queiroz8.pdf: 155984 bytes, checksum: f5c4a46d60e77b0718848fab96f85373 (MD5) Dissertação Christiano Queiroz7.pdf: 1461220 bytes, checksum: 621ab609ba799dba10e909031c8cccc9 (MD5) Dissertação Christiano Queiroz6.pdf: 1474051 bytes, checksum: c8186f90fc20cb7c9db3cd0f92c1c773 (MD5) Dissertação Christiano Queiroz5.pdf: 860472 bytes, checksum: 1e0bb30340dc455ba5886425887a6b73 (MD5) Dissertação Christiano Queiroz4.pdf: 145777 bytes, checksum: 002d8ab1dd097ffae4cef5a4ac414724 (MD5) Dissertação Christiano Queiroz3.pdf: 175599 bytes, checksum: 87cbe8be31bd0209f31d80cfd461be9c (MD5) Dissertação Christiano Queiroz2.pdf: 159009 bytes, checksum: 8b8dae41086fcfc427e8a67780010cc4 (MD5) Dissertação Christiano Queiroz1.pdf: 195113 bytes, checksum: 4c0bba61fcc22b702a39d4a21f319e93 (MD5) Previous issue date: 2007
A avaliação radiográfica convencional da consolidação de fraturas é um método pouco confiável, não apenas por depender da experiência do examinador, como também da qualidade do exame. Desta forma, imagens seriadas que apresentem densidade e contraste não uniformes ou diferenças de projeção geométrica podem determinar o diagnóstico incorreto da reparação de fraturas após seu tratamento. Mesmo imagens consideradas suficientes para o diagnóstico podem não permitir a observação de mudanças sutis nos tecidos mineralizados devido à sua baixa sensibilidade e devido à limitada acuidade visual humana. O emprego, entretanto, de métodos de investigação mais sensíveis e objetivos poderia aumentar a acurácia dessa avaliação. Este estudo objetivou comparar, por meio de radiografias panorâmicas digitalizadas, a reparação dos traços de fraturas mandibulares, após a instituição de duas formas diferentes de tratamento: a redução aberta, seguida da imobilização dos fragmentos com materiais de fixação interna (grupo controle), e a redução fechada com a fixação intermaxilar (grupo teste). Para isto, os pacientes foram submetidos a três exames radiográficos pós-operatórios (uma semana, um mês e três meses após o tratamento), que, após digitalizados (600 dpi, 8 bits), foram corrigidos em brilho e tamanho no Programa Photoshop. Em seguida essas imagens foram analisadas por três diferentes métodos no Programa ImageTool®: análise visual no vídeo, mensuração da média e do coeficiente de variação dos níveis de cinza e por subtração radiográfica digital. Os resultados revelaram a predominância de áreas de neoformação óssea no grupo tratado com fixação interna, em todos os tempos avaliados. Assim, pode-se concluir que a redução aberta com fixação interna das fraturas mandibulares determinou uma reparação em menor tempo que a redução fechada por meio da fixação intermaxilar.
Salvador
Zogaib, Rodrigo Kallás 1973. "Osteossíntese minimamente invasiva com uso de placas em ponte das fraturas transversas da diáfise do úmero (Classificadas pela Ao-Assif como 12.A3)." [s.n.], 2013. http://repositorio.unicamp.br/jspui/handle/REPOSIP/308489.
Full textDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas
Made available in DSpace on 2018-08-22T13:03:57Z (GMT). No. of bitstreams: 1 Zogaib_RodrigoKallas_M.pdf: 9326160 bytes, checksum: a09bd895633ff41c62b544b7b84de884 (MD5) Previous issue date: 2013
Resumo: Entre novembro de 2000 e abril de 2011, 22 pacientes com 23 fraturas transversas da diáfise umeral foram tratados com redução indireta e fixação com placa e parafusos através de técnica minimamente invasiva. A seguimento pós-operatório variou de 6 a 126 meses ( media 51.6 meses). Quinze pacientes, eram do sexo masculino e sete feminino. A idade dos pacientes variou de 18 a 66 (media 33.5) anos. Todas as fraturas consolidaram, e nenhuma apresentou lesão neurovascular associada. As fraturas consolidaram em até 2.7 meses. O arco de movimento do ombro e cotovelo foram simétricos quando comparado ao lado não envolvido, salvo em um paciente que apresentou-se com déficit de extensão do cotovelo, mas tinha fratura de olecrano ipsilateral, e foi tratado com redução e fixação com banda de tensão. Houve complicações sem repercussão clínica em sete casos, que foram o cúbito varo de aproximadamente 5 graus em cinco pacientes e falha dos parafusos proximais em 2 casos. Não houve ocorrência de infeção ou lesão iatrogênica do nervo radial A avaliação da função pós operatória do braço, ombro, e mão (DASH SCORE) foi testada e variou de 0 a 12.5 ( media de 5.45) Em conclusão, osteossíntese minimamente invasiva com placa em ponte (MIPO) , pode ser considerada uma opção segura e eficaz para o tratamento de fraturas transversas da diáfise do úmero
Abstract: Between November 2000 and April 2011, 22 patients with 23 transverse mid-shaft humeral fractures were treated with minimally invasive plate osteosynthesis techniques. Follow-up duration ranged from 6 to 126 (mean 51.6) months. Fifteen patients were male and seven were female. The age of the patients ranged from 18 to 66 (mean 33.5) years. All fractures healed and no associated neurovascular lesion developed. All fractures united within an average of 2.5 months. Ranges of shoulder and elbow motion were symmetric with those of the uninjured extremity. Complications occurred in seven cases, in five cases, comprising 5° cubitus varus with no functional repercussion, and in two cases, the proximal screw failed, but the fracture healing in the same mean time. Disabilities of the arm, shoulder, and hand (DASH) scores ranged from 0 to 12.5 (mean 5.45). One patient who presented with lack of elbow extension was found to have an ipsilateral olecranon fracture, which was treated with tension-band osteosynthesis. No infection or iatrogenic injury of the radial nerve occurred. In conclusion, minimally invasive bridging-plate osteosynthesis may be considered an option for the treatment of transverse mid-shaft humeral fractures
Mestrado
Fisiopatologia Cirúrgica
Mestre em Ciências
Moura, Andrezza Lauria de 1982. "Análise fractográfica e de resistência mecânica de duas marcas de placas de titânio em fraturas simuladas em corpo de hemimandíbulas de alumínio." [s.n.], 2013. http://repositorio.unicamp.br/jspui/handle/REPOSIP/287837.
Full textDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-23T00:56:38Z (GMT). No. of bitstreams: 1 Moura_AndrezzaLauriade_M.pdf: 4155630 bytes, checksum: 44572134d9e31084a7892cb0866a1d79 (MD5) Previous issue date: 2013
Resumo: O propósito no estudo foi avaliar comparativamente, através de teste de carregamento linear e análise fractográfica, duas marcas de material de fixação interna estável com dois métodos de fixação em fraturas simuladas em corpo de hemimandíbulas de alumínio. O trabalho foi dividido em dois grupos: Grupo I com duas estruturas de alumínio semelhantes à hemimandíbulas e fixação com duas placas de titânio de quatro furos do sistema 2,0mm, sendo uma placa na zona de compressão e outra zona de tensão, totalizando 20 placas de titânio; e grupo II, com duas estruturas de alumínio semelhantes à hemimandíbulas e fixação de uma placa de titânio de quatro furos do sistema 2,0mm na zona neutra de corpo de mandíbula, totalizando 10 placas de titânio. Testes de carregamento linear foram realizados por meio da máquina para ensaio universal mecânica Instron®, até a fratura do material. Após os testes, foram realizadas as análises fractográficas das superfícies de fratura dos materiais de fixação (grupos I e II) através de microscópio eletrônico de varredura FEI®, com o objetivo de analisar orientações, texturas e falhas dos materiais. Médias e desvio padrão das cargas e deslocamentos foram avaliados aplicando-se a Análise de Variância (ANOVA) two-way e teste de Tukey em nível de significância de 5%. Os resultados mostraram que o método de fixação com duas placas retas de quatro furos apresentou maior resistência à carga (p<0,01), quando comparado ao grupo de apenas uma placa de titânio na zona neutra mandibular. Ainda, a marca Traumec® apresentou maior resistência mecânica (p<0,01) quando utilizada no método com duas placas de fixação e a marca Tóride® (p<0,01) apresentou maior resistência as carga quando utilizada no método com apenas uma placa de fixação. A fractografia informou que todas as fraturas ocorreram por sobrecarga dúctil e micromecanismo alveolar
Abstract: The purpose of the study was to comparatively evaluate, through linear load test and fractographic analysis, two brands of stabel internal fixation in two methods of fixation in simulated body fractures in aluminium hemimandibules. The study was divided into two groups: Group I with two aluminum structures similar to hemimandibles for fixation of one 2,0mm miniplate in the compression zone and another one in tension zone, totaling 20 miniplates; and group II, with two aluminum structures similar to hemimandibles for fixation of one 2,0mm miniplate in the neutral zone of the mandible, totaling 10 miniplates. Mechanical tests were performed via mechanical universal testing machine Instron¿ until complete failure of the material. After the tests, fractography analysis of fractured surfaces were done in all materials (groups I and II) by a FEI¿ scanning electron microscopy, with the objective of analyzing orientation and textures of materials failures. Means and standard deviations of load and displacement were evaluated by applying the analysis of variance (ANOVA) two-way and the Tukey test at a significance level of 5%. The results showed that the method of fixation with two titanium plates with four holes showed higher resistance loads (p<0,01), when compared to only one titanium plate in the neutral zone of the mandible. Furthermore, the brand Traumec¿ showed higher mechanical strength (p<0,01) when used in the method with two fixing plates and the brand Toride¿ (p<0,01) showed a higher resistance to loads when used in the method with only one miniplate. The fractography reported that all fractures occurred in ductile overload and alveolar micromechanisms
Mestrado
Cirurgia e Traumatologia Buco-Maxilo-Faciais
Mestra em Clínica Odontológica
Mukka, Sebastian. "Aspects on treatment of femoral neck fractures : studies on treatment methods, surgical approach and external validity." Doctoral thesis, Umeå universitet, Ortopedi, 2015. http://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-108269.
Full textLårbenshalsfrakturer (FNF) är en utmaning för dagens sjukvård och förknippad med hög mortalitet i den äldre befolkningen. FNF orsakas främst av lågenergitrauma efter fall i samma plan hos patienter med benskörhet. Total höftledsprotes (THA) har visat sig ge en bättre höftfunktion, livskvalitet med färre omoperationer hos äldre patienter än sluten reposition samt fixering med skruvar (IF) under de första två-fyra åren efter operation. Få studier har publicerats med långtidsuppföljning av THA jämfört med IF. Vid behandling av felställd FNF med halv höftledsplastik (HA) eller THA finns olika kirurgiska metoder (snittföring) för implantation av protesen. Majoriteten av ortopedkliniker i Sverige använder direkt lateral (DL) eller posteriolateral (PL) snittföring. PL har kopplats till en ökad risk för luxation av protesen (urledsvridning), vilket i sin tur genererat en högre risk för omoperation jämfört med DL. Få studier har utvärderat höftfunktion med avseende på snittföring. Detsamma gäller vilka radiologiska faktorer som påverkar risken förprotesluxation. Det finns olika typer av studiedesigner för utvärdering av medicinska och kirurgiska behandlingsmetoder. Studiedesignen med högst bevisvärde anses vara den randomiserade kontrollerade studien (RCT). För att en RCT skall hålla hög kvalitet krävs intern och extern validitet. Intern validitet syftar på ett korrekt studieupplägg som mäter det som avses och undviker påverkan av icke önskvärda faktorer. Extern validitet (EV) innebär att erhållna resultat från studien är generaliserbara och kan extrapoleras till andra grupper än den studerade. Det inga rapporter i ortopediska litteraturen med fokus på EV med patienter som drabbats av FNF. Studie I: Prospektiv randomiserad studie av 100 patienter med en felställd FNF jämförs THA med IF med avseende på höftfunktion och reoperationer. Uppföljning gjordes efter tre månader samt 1, 2, 4, 11 och 17 år. HHS som mått på höftfunktion var högre och andelen reoperationer lägre för patienter som behandlades med THA. Studie II: Prospektiv kohortstudie med 183 patienter med felställd FNF behandlade med HA och antingen DL eller PL. Vi fann ingen skillnad i patientrapporterad höftfunktion utvärderat med HHS och WOMAC efter 1 år men en ökad förekomst av hälta vid DL. Studie III: Retrospektiv kohortstudie av 373 patienter opererade med en cementerad bipolär HA och PL. Postoperativa röntgenbilder granskades avseende femoral offset (FO), postoperativ benlägdsskillnad (LLD) samt acetabulär Wibergvinkel och relaterades till återkommande protesluxationer. Detta relaterades till återkommande luxationer. Uppföljningstiden varierade mellan 6 månader och 7 år. Patienter med återkommande luxationer hade en minskad postoperativ global FO, förkortad LLD och grundare acetabulum på den opererade sidan jämfört med kontroller. Studie IV: Prospektiv kohortstudie av 840 patienter med felställd FNF där patienter som ingick i en RCT jämförs med de som inte gav sitt samtycke för deltagande eller ej inkluderats i screeningprocessen. De patienterna som inte gav sitt samtycke hade ökad dödlighet, men ingen skillnad i höftfunktion jämfört med deltagare. Slutsatser • Friska och kognitivt vitala äldre patienter med god höftfunktion innan en felställd lårbenshalsfraktur bör behandlas med total höftledsprotes. • DLsnittföring ger ett lika bra patientrapporterad höftfunktion men en ökad förekomst av hälta jämfört med PL snitt vid behandling med halvprotes på grund av en felställd lårbenshalsfraktur. • Ansträngning bör göras för att återställa benlängdsskillnad samtfemoral offset och därigenom minska risken för återkommande luxation. • Våra resultat tyder på att patienter som deltar i en randomiserad studie har lägre dödlighet än patienter som avböjt att delta samt de som missats i screeningprocessen. Det är viktigt att ta hänsyn till när extrapolerar studieresultat till ett hälso-och sjukvårdssystem. Detta bör vägas in i värderingen av studieresultatens externa validitet.
Bastos, Endrigo Oliveira. "Avaliação do tratamento cirúrgico das fraturas de côndilo mandibular pelo acesso retromandibular transparotídeo." Universidade de São Paulo, 2010. http://www.teses.usp.br/teses/disponiveis/5/5158/tde-21122010-120024/.
Full textINTRODUCTION: Open reduction and rigid internal fixation through retromandibular transparotid approach has been increasingly accepted as one of the options for treatment of fractures of the mandibular condyle, which is still a controversial subject. OBJECTIVES: To evaluate surgical treatment through retromandibular transparotid approach for extracapsular fractures of mandibular condyle in adults. METHODS: Ten consecutive patients operated on by the author at University of São Paulo Medical School Hospital were retrospectively evaluated. All of them were adults with extracapsular fractures of mandibular condyle causing shortening greater than 2 mm or deviation greater than 10 degrees. Patients were operated through retromandibular transparotid approach and had their pre and postoperative CT scans assessed with tridimensional reconstruction. Quality of reduction at fracture site was classified as optimal, satisfactory or poor. In seven patients with unilateral fractures, non-fractured sides served as controls in quantitative assessment condylar head positioning. Variables condylar height and sagittal, axial and coronal inclinations were measured in preoperative and postoperative CT scans, on fractured and not fractured sides. The different measures were compared. On morbidity of the approach, were evaluated: facial animation asymmetry, incidence of salivary fistula or infection and quality of scar. At least 18 months after surgery, patients were called for an assessment of postoperative period. They were asked about the presence of clicking joints, limitation on mouth opening, facial pain and poor mastication. Situation at postoperative period was compared with the one previous to trauma. Patients were examined for clicking or pain on palpation, uncorrected intercuspation, chin deviation on mouth opening and limitation on protrusion or laterality. The maximum mouth opening was measured. RESULTS: At the fracture site, reduction was rated as satisfactory or ideal in nine patients. As for the positioning of the condylar head, for the variables height and coronal condylar inclination, preoperatively, there was statistical difference between fractured and normal sides. Postoperatively, there was no difference for any variable when comparing fractured and normal sides. There were no asymmetries in facial animation, salivary fistula or infection since immediate postoperative period. One patient had hypertrophic scar. In the late postoperative period, were found: maximum mouth opening between 39 and 55 mm, chin deviation at oral opening in one patient and the emergence of clicking in two, data that was not statistically different from the period before the trauma. CONCLUSIONS: Treatment of shortened or deviated extracapsular fractures of the mandibular condyle in adults by open reduction and rigid internal fixation through retromandibular transparotid approach can provide correction of condylar anatomy with low morbidity and satisfactory functional outcome
Gracitelli, Mauro Emilio Conforto. "Estudo randomizado da osteossíntese das fraturas da extremidade proximal do úmero com placa ou haste intramedular." Universidade de São Paulo, 2015. http://www.teses.usp.br/teses/disponiveis/5/5140/tde-24022016-091653/.
Full textINTRODUCTION: Fractures of the proximal humerus are common, with an increasing incidence in the elderly and with a high impact on quality of life and shoulder function. For displaced fractures, the locking plate is the most used method of osteosynthesis. Studies have shown good clinical results with the use of locking plates, but also with the fixation with locking intramedullary nail. The aim of this study was to compare the clinical outcomes, radiographic results and the complications between these two methods in patients with displaced proximal humerus fractures. METHODS: In this prospective, randomized clinical trial, 72 patients with displaced fractures of the proximal humerus, classified as Neer 2- or 3-part, were randomly assigned to receive osteosynthesis with either locking plate (36 patients - Plate Group) or locking intramedullary nail (36 patients - Nail Group). The clinical outcomes were evaluated at 3, 6 and 12 months and included the Constant and Murley, University of California at Los Angeles (UCLA) and Disability of Arm, Shoulder and Hand (DASH) scores, visual analog scale (VAS) and the passive range of motion. Radiographic findings (consolidation and head shaft angle) and complications, which included the evaluation of rotator cuff by ultrasound, were also evaluated. The primary outcome was the Constant and Murley score at 12 months. RESULTS: Sixty-five patients completed 12 months of follow-up, 32 in the Nail Group and 33 in the Plate Group. The mean Constant score at 12 months was 70.3 points for the Nail Group and 71.5 points for the Plate Group (p = 0.750) and the mean Relative Constant score was 81% for the Nail Group and 85% points for the Plate Group (p = 0.400). There was also no difference at 3 and 6 months for the Constant score. VAS, DASH and radiographic findings also did not differ at 3, 6 and 12 months. Range of motion showed a 2.1 points difference in favor of the Nail Group for medial rotation at 6 months (p = 0.042), with no difference for the other motions at 3, 6 and 12 months. The UCLA score presented a difference of 4.0 points at 3 months, with better results for the Nail Group (p = 0.005), but no significant difference at 6 and 12 months. Thirty-eight complications were recorded, 28 in the Nail Group and 10 in the Plate Group, with significant difference (p = 0.001). Complications occurred in 18 patients, 11 (34%) of the Nail Group and seven (21%) of the Plate Group, with no significant difference (p = 0.137). CONCLUSIONS: Locking plates and locking intramedullary nail yielded similar clinical and radiographic results. Locking intramedullary nail fixation has a higher risk for complications and reoperations
Olofsson, Birgitta. "Old people with femoral neck fracture : delirium, malnutrition and surgical methods - an intervention program." Doctoral thesis, Umeå : Univ, 2007. http://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-1049.
Full textMorita, Augusto Teruo. "Placas e parafusos polimericos auto-reforçados para fixação interna rigida de fraturas." [s.n.], 2006. http://repositorio.unicamp.br/jspui/handle/REPOSIP/248658.
Full textTese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica
Made available in DSpace on 2018-08-06T15:37:34Z (GMT). No. of bitstreams: 1 Morita_AugustoTeruo_D.pdf: 5448584 bytes, checksum: b45ea2a6a097d79180fbd6e43996e982 (MD5) Previous issue date: 2006
Resumo: O objetivo deste trabalho foi preparar placas e parafusos auto-reforçados a partir do copolímero poli(L/DL ácido láctico), para serem utilizados na fixação interna rígida de fraturas. Este copolímero pode ser hidrolisado quando inserido no corpo humano e seus produtos de degradação são expelidos através do ciclo metabólico. Foi construído um aparelho de autoreforçamento que deve ser acoplado a uma Máquina Universal de Ensaios, capaz de orientar uniaxialmente amostras poliméricas através da passagem por uma matriz aquecida de dimensões menores que a amostra. Foram realizados ensaios prévios de auto-reforçamento com amostras de poliestireno. Ensaios de auto-reforçamento com o copolímero poli(L/DL ácido láctico) mostraram que o auto-reforçamento induziu um aumento nas propriedades mecânicas, medidas sob flexão, de ~60% no módulo de elasticidade e de ~90% na tensão máxima. A amostra moldada apresentou linhas brancas quando dobrada a temperatura ambiente, indicando a fragilização. Por outro lado, as amostras auto-reforçadas podem ser dobradas a temperatura ambiente sem que ocorresse ruptura frágil ou fragilização. Através de ensaios de difração de raios-X determinou-se que a amostra é semi-cristalina após o auto-reforçamento, apesar dos ensaios de calorimetria diferencial de varredura não identificarem positivamente a formação desta estrutura semi-cristalina. A esterilização por raios-g causa uma grande queda na massa molar, porém não altera as propriedades mecânicas. Ensaios de degradação in-vitro, com solução tampão de fosfato numa temperatura de 37 °C, das amostras esterilizadas mostraram que a massa molar sofre uma queda durante todo o ensaio de degradação e as propriedades mecânicas sofrem uma pequena queda após 15 semanas. As amostras auto-reforçadas podem ser usinadas na forma de placas e parafusos. As placas usinadas do copolímero de poli(ácido láctico) ainda podem ser dobradas a temperatura ambiente sem que ocorra quebra ou formação de linhas brancas
Abstract: In this work self-reinforced plates and screws to be used for rigid internal fixation of fractures were produced using the poly(L/DL-lactic acid) copolymer. This copolymer can be hydrolyzed when implanted in the human body and its degradation products are expelled by the metabolic cycle. A self-reinforcement module was built. It can be attached to a Universal Mechanical Testing Machine, which is capable to uni-axially orient the polymeric sample though a heated die. Initial tests of processing and self-reinforcement were conducted with polystyrene. Self-reinforcement tests were conducted with the poly(L/DL-lactic acid) copolymer. The results show that the die-drawing process induced an increase in the flexural mechanical properties of ~60% in the elastic modulus and of ~90% in the maximum tension, both measured under flexion conditions. White lines (crazing) appears when the molded sample was bent at ambient temperature, whereas the self-reinforced sample could be bent in the same conditions without fracture or sample fragilization. X-ray diffraction results indicated that the self-reinforced sample exhibits a semi-crystalline structure; notwithstanding the differential scanning calorimetry results do not conclusively identify the sample morphology. g-rays sterilization caused a decrease in the molar mass, but the mechanical properties were not affected. In-vitro degradation test were conducted at 37 °C in a buffered aqueous solution. Sterilized samples show a larger decrease in the molar mass since the beginning of the test, but the mechanical properties exhibits a smaller decrease during the test. The self-reinforced samples can be molded to the form of plates and screws. The final sample could be bent at ambient temperature without fragilization
Doutorado
Quimica Inorganica
Doutor em Ciências
Mendes, Marcelo Breno Meneses 1984. "Estudo mecânico e microestrutural em dois sistemas de fixação interna usados em osteotomia sagital mandibular." [s.n.], 2014. http://repositorio.unicamp.br/jspui/handle/REPOSIP/288763.
Full textTese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-24T03:19:50Z (GMT). No. of bitstreams: 1 Mendes_MarceloBrenoMeneses_D.pdf: 3820602 bytes, checksum: 7c13797c10676481e3ebfd0492c570a9 (MD5) Previous issue date: 2014
Resumo: O objetivo deste estudo foi avaliar, através da análise de rugosidade superficial, microscopia eletrônica de varredura (MEV), análise de composição através de espectroscopia de raios-X e análise de resistência mecânica, dois diferentes sistemas de fixação interna usados em fixação de osteotomia sagital do ramo mandibular. Foram selecionadas cinco placas retas do sistema 2,0 mm com quatro furos e 20 parafusos de 6 mm de comprimento de dois sistemas de fixação interna, grupo I: Tóride (Tóride Indústria e Comércio Ltda. -Mogi Mirim, São Paulo -Brasil) e grupo II: Medartis (Medartis AG -Basel, Suíça). Para os testes mecânicos, foram selecionadas dez hemimandíbulas de poliuretano, dividindo-as igualmente entre os grupos I e II. Inicialmente, foi realizada análise de rugosidade superficial em todas as placas dos dois sistemas, e os dados foram submetidos à análise de variância e teste de Tukey (p>0,05) para a comparação entre as médias. Em seguida, as mesmas placas foram avaliadas no espectrômetro por meio de difração de raios-X e logo após foram analisadas no MEV. Por último, foi realizado o teste mecânico, no qual as hemimandíbulas de poliuretano foram fixadas e submetidas ao teste de carregamento (1mm/min). Os dados foram analisados quanto à carga de pico (em Newtons) e o deslocamento de pico (em mm) para todos os grupos estudados, e posteriormente submetidos ao teste t. Os grupos testados apresentaram vestígios superficiais dos processos de usinagem, principalmente nas margens dos elos. O grupo II apresentou revestimento com uma camada de nitreto de titânio. A análise da rugosidade revelou diferença entre as regiões de centro e margem da placa para o grupo I; diferente do grupo II, o qual apresentou valor de rugosidade menor e mais uniforme. O teste mecânico revelou que o grupo II apresentou maior carga de pico. Os dados demonstraram que há diferença microestrutural e mecânica entre os grupos testados.
Abstract: The aim of this study was to evaluate, through surface roughness analysis, scanning electron microscopy (SEM), composition analysis by X-ray spectroscopy and analysis of mechanical strength, two different systems used in internal fixation of mandibular sagittal split osteotomy fixation. Five straight 2.0 mm system plates with four holes and 20 screws 6 mm length of two internal fixation systems were selected, group I: Toride (Toride Indústria e Comércio Ltda -Mogi Mirim, São Paulo -Brazil.) and group II: Medartis (Medartis AG -Basel, Switzerland). For mechanical testing, ten polyurethane hemimandibles were used, distributing them equally into groups I and II. Initially, surface roughness analysis was performed on all plates of the two systems, and the data were subjected to analysis of variance and Tukey's test (p> 0.05) for comparison between means. Then, the same plates were evaluated in the spectrometer by means of X-ray diffraction and after this evaluation, they were subjected to SEM. Finally, mechanical testing was performed, in which the polyurethane mandibles were fixed and subjected to the load (1mm/min) test on an Instron testing machine, Model 4411 (Instron Corp., Norwood, MA). Data were analyzed for peak load (in Newtons) and peak displacement (in mm) for all groups, and then subjected to t test. The groups tested showed superficial traces of machining processes, especially on links periphery. Group II had coated with a layer of titanium nitride. The roughness analysis revealed differences among the regions of the center and edge of the plate for group I; group II showed roughness value smaller and more uniform, than group I.The mechanical test showed that group II had higher peak load. The data demonstrated that there are microstructural and mechanical differences between the tested groups.
Doutorado
Cirurgia e Traumatologia Buco-Maxilo-Faciais
Doutor em Clínica Odontológica
Celegatti, Filho Tóride Sebastião 1966. "Desenvolvimento de placas para fixação interna rígida : estudo da resistência a compressão em fraturas simuladas de côndilo da mandíbula." [s.n.], 2013. http://repositorio.unicamp.br/jspui/handle/REPOSIP/290054.
Full textDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-23T15:57:19Z (GMT). No. of bitstreams: 1 CelegattiFilho_TorideSebastiao_M.pdf: 4195192 bytes, checksum: e279d02d5c5aabef9927997e90717129 (MD5) Previous issue date: 2013
Resumo: O propósito neste estudo foi desenvolver placas em forma de Y com espessuras de 0,6, 1,0 e 1,5 mm para ser usadas em fratura de colo de côndilo da mandíbula e submetê-las ao ensaio de resistência mecânica de compressão. Fo-ram desenvolvidas 10 placas em Y para cada espessura, contendo 8 furos. As placas foram confeccionadas de acordo com projeto idealizado pelo autor e fabricado pela empresa Toride Indústria e Comércio Ltda., Mogi Mirim, SP, Brasil. As placas foram confeccionadas com titânio comercialmente puro (grau ll), conforme norma ASTM F-67. Os processos para desenvolvimento das placas foram feitos em programa de desenho mecânico Solid Works. A confecção das placas seguiu a metodologia de fabricação já existente na empresa, compreendendo processo de usinagem em equipamento modelo Discovery Romi de 4 eixos, o qual mantém precisão e controle dimensional com tolerância de ± 0,10 mm. Foram também confeccionadas 30 hemi-mandíbulas do lado esquerdo, com resina de poliuretano rígido de densidade 40 a 50 PCF onde as placas foram fixadas para conter fratura simulada da cabeça do côndilo. O teste de carregamento foi executado na máquina para ensaio universal Instron, modelo 4411, aplicando carga na posição médio-lateral e ântero-posterior na cabeça do côndilo. ANOVA com 2 fatores e teste de Tukey com 5% de significância foram aplicados nos resultados. Quando a carga foi aplicada no sentido médio-lateral, a placa de maior espessura (1,5 mm) obteve a maior resistência, mas sem diferença estatística entre os deslocamentos de 5,0 e 10,0 mm. No sentido ântero-posterior, a placa com maior resistência foi a de menor espessura, seguida pela de maior espessura. Pode-se concluir que: 1 - No sentido médio-lateral, os maiores valores de resistência foram observados no deslocamento de 15 mm, exceto para as placas 0,6 e 1,5 mm com valores similares em 10 e 20 mm respectivamente; 2 - A placa com espessura de 1,5 mm foi a única que apresentou maior valor médio em todos os deslocamentos; 3 - No sentido ântero-posterior, os maiores valores de resistência foram vistos no deslocamento de 15 mm e os menores em 5 mm para todas as espessuras de placas; 4 - A placa com espessura de 0,6 mm foi a que apresentou maiores valores em todos os deslocamentos e 5 - No sentido ântero-posterior, o carregamento de 20 mm não foi alcançado
Abstract: The purpose of this study was to develop a Y plate with thicknesses of 0.6, 1.0 and 1.5 mm for use in condylar mandible fracture and submit them to the me-chanical strength testing Compression. For this study 30 plates were used for surgical containment internal, Y geometry and holes 8, 10 plates with a thickness of 0.6 10 mm plates with 1.0 mm thickness and 10 plates with thickness of 1.5 mm. This model plate was designed by the author and manufactured by Toride Industry e Comercio Ltda., Mogi Mirim, Brazil. The plates were made from commercially pure titanium (grade II), according to ASTM F-67. The processes for developing the plates were made in program Solid Works mechanical design engineering company by Toride, following the procedures of the project. The making of the plates followed the methodology in an existing manufacturing company, including process equipment machining model Romi Discovery of 04 axes, which keeps ac-curacy and dimensional control with a tolerance of ± 0.10 mm, required by the quality system of the company Toride. Were prepared hemi-jaws 30 on the left side with hard polyurethane resin density 40-50 PCF where the plates were fixed. The load test was run on the test equipment universal Servohidráulico Instron Model 4411 (Instron Corp., Norwood, MA.), and will have to evaluate the strength of plates attached Hemi-mandibles applying the force in mid-lateral position, and the force applied at Antero-posterior position, were predetermined three shifts, ob-taining values of average load in the three, Statistical analysis of variance by ANOVA used 02 factors, the Tukey test at 5% significance level was applied. When the load was applied in the medial-lateral plate of greater thickness (1.5 mm) gave the highest strength, but no statistical difference in displacement of 5.0 and 10.0 mm. Antero-posterior direction on the plate was the biggest strength of thinner, following the greater thickness. It can be concluded that: 1 - In the medial - lateral direction, the highest values of resistance were observed in the displacement of 15 mm, except for the 0.6 and 1.5 mm plates with similar values in 10 and 20 mm respectively; 2 - A plate with thickness of 1.5 mm was the one with the highest average value on all shifts; 3 - In the antero-posterior direction, the highest values of resistance were seen in the displacement of 15 mm and 5 mm in the minors for all thicknesses of plates; 4 - A plate with thickness of 0.6 mm showed the highest values in all shifts and; 5 - In the antero-posterior direction, the loading of 20 mm was not achieved
Mestrado
Materiais Dentarios
Mestre em Materiais Dentários
Bassit, Ana Cristina Ferreira. ""Efeito da terapia por ondas de choque na consolidação óssea após osseossíntese de fêmur com hastes bloqueadas: estudo experimental em cães (canis familiaris)"." Universidade de São Paulo, 2004. http://www.teses.usp.br/teses/disponiveis/5/5160/tde-13092006-140217/.
Full textThe effect of extracorporeal shock wave therapy (ESWT) on bone healing, after bilateral femoral osteotomies and osteosynthesis with interlocking nails, was studied in 8 dogs. The right femurs composed the control group, and the left femurs, the treated group, which received 2000 pulses of shock wave, with 18 kV, 5 mJ (-6dB) energy on the fracture line. Radiographs after 4, 8 and 12 weeks, revealed increased periosteal proliferation in the treated group. The results (treated/control ratio) of the scintigraphic exams, performed on weeks 2, 4, 6, 8, 10 and 12, were statistically higher for the treated group. The ESWT led to increased osteogenic activity on acute fracture's bone healing.
Ip, Wing-yuk. "Design and biomechanical study of internal fixation devices for difficult phalangeal fractures." Click to view the E-thesis via HKUTO, 2002. http://sunzi.lib.hku.hk/hkuto/record/B3197966X.
Full text葉永玉 and Wing-yuk Ip. "Design and biomechanical study of internal fixation devices for difficult phalangeal fractures." Thesis, The University of Hong Kong (Pokfulam, Hong Kong), 2002. http://hub.hku.hk/bib/B3197966X.
Full textFurukawa, Taizo. "High-strength hydroxyapatite/poly (L-lactide) composites for internal fixation of bone fractures." Kyoto University, 2000. http://hdl.handle.net/2433/180873.
Full textSia, Charles Pactol, and 謝漢明. "Internal versus intermaxillary fixation in vertical subsigmoid osteotomy for mandibular setback: arandomized controlled trial." Thesis, The University of Hong Kong (Pokfulam, Hong Kong), 2011. http://hub.hku.hk/bib/B46600097.
Full textChow, Lop-keung Raymond. "Clinical morbidity of resorbable plates and screws for internal fixation in orthognathic surgery." Click to view the E-thesis via HKUTO, 2003. http://sunzi.lib.hku.hk/hkuto/record/B31954285.
Full textChow, Lop-keung Raymond, and 周立強. "Clinical morbidity of resorbable plates and screws for internal fixation in orthognathic surgery." Thesis, The University of Hong Kong (Pokfulam, Hong Kong), 2003. http://hub.hku.hk/bib/B31954285.
Full textJanicek, John Charles. "In vitro three dimensional biomechanical comparison of two internal fixation methods in equine adult radii." Diss., Columbia, Mo. : University of Missouri-Columbia, 2007. http://hdl.handle.net/10355/4927.
Full text"August 2007" The entire dissertation/thesis text is included in the research.pdf file; the official abstract appears in the short.pdf file (which also appears in the research.pdf); a non-technical general description, or public abstract, appears in the public.pdf file. Includes bibliographical references.
Rosa-Ballaben, Nátalie Massaro. "Osteossíntese minimamente invasiva com placa bloqueada nas fraturas de tíbia em cães /." Jaboticabal, 2014. http://hdl.handle.net/11449/110436.
Full textBanca: Cláudia Valéria Seullner Brandão
Banca: Paola Castro Moraes
Resumo: Avanços na compreensão da biologia óssea e das complicações das fraturas têm levado a modificações na abordagem da fixação interna das mesmas, sendo a osteossíntese minimamente invasiva com placa (MIPO) uma das mais recentes evoluções para o manejo biológico das fraturas. O objetivo do presente estudo foi avaliar o uso de placas bloqueadas aplicadas de forma minimante invasiva em fraturas de tíbia de cães. Foram utilizados 10 cães apresentando fraturas de tíbia, de idades e raças variadas. Os animais foram avaliados quanto a deambulação, intensidade do edema, exames radiográficos, e densitometria óptica nos períodos 0, 15, 30, 60, 90 e 120 dias de pós-operatório. Após 15 dias de pós-operatório 80% dos cães já utilizavam o membro ao caminhar e apresentavam formação de edema leve a ausente no membro operado. Após 30 dias de pós-operatório 100% dos cães já apoiavam o membro ao caminhar e não apresentavam formação de edema no membro. Todos os pacientes apresentaram sinais radiográficos e densitométricos de início de consolidação óssea após 15 dias de pós-operatório. O tratamento de fraturas de tíbia por meio da MIPO é uma alternativa eficaz, resultando em utilização precoce do membro e união clínica efetiva, e pode ser realizada sem uso de intensificadores de imagem
Abstract: Advances in the comprehension of the bone healing and complications of the treatment of the fractures have been changed some concepts. Less invasive procedures have been advocated. A minimally invasive plate osteosynthesis (MIPO) is one of the best ways to avoid over tissue damage. The aim of this study was to evaluate the use of MIPO in tibial fractures in dogs. Ten dogs presenting a tibial fracture were used. Deambulation, swelling intensity and radiographic changes were evaluated preoperatively, just after the procedure and at 15, 30, 60, 90 e 120 days postoperatively. Six of 10 (60%) dogs were able to walk at 15 days postoperatively with slight swelling and mild lameness. Two of 10 (20%) presented normal walking at the same period. At 30 days postoperatively all dogs were able to walk normally. Six of them were not lame and 9 did not present swelling. Bone healing could be followed by radiographic evaluation. All dog presented initial radiographic signs of bone healing after 15 days postoperatively. Two of 10 showed clinical union at this time. In five of 10 (50%) clinical union could be observed after 60 days. The treatment of tibial fractures by MIPO is an effective alternative resulting in early and effective clinical union and can be performed without the use of image intensifiers
Mestre
Rosa-Ballaben, Nátalie Massaro [UNESP]. "Osteossíntese minimamente invasiva com placa bloqueada nas fraturas de tíbia em cães." Universidade Estadual Paulista (UNESP), 2014. http://hdl.handle.net/11449/110436.
Full textAvanços na compreensão da biologia óssea e das complicações das fraturas têm levado a modificações na abordagem da fixação interna das mesmas, sendo a osteossíntese minimamente invasiva com placa (MIPO) uma das mais recentes evoluções para o manejo biológico das fraturas. O objetivo do presente estudo foi avaliar o uso de placas bloqueadas aplicadas de forma minimante invasiva em fraturas de tíbia de cães. Foram utilizados 10 cães apresentando fraturas de tíbia, de idades e raças variadas. Os animais foram avaliados quanto a deambulação, intensidade do edema, exames radiográficos, e densitometria óptica nos períodos 0, 15, 30, 60, 90 e 120 dias de pós-operatório. Após 15 dias de pós-operatório 80% dos cães já utilizavam o membro ao caminhar e apresentavam formação de edema leve a ausente no membro operado. Após 30 dias de pós-operatório 100% dos cães já apoiavam o membro ao caminhar e não apresentavam formação de edema no membro. Todos os pacientes apresentaram sinais radiográficos e densitométricos de início de consolidação óssea após 15 dias de pós-operatório. O tratamento de fraturas de tíbia por meio da MIPO é uma alternativa eficaz, resultando em utilização precoce do membro e união clínica efetiva, e pode ser realizada sem uso de intensificadores de imagem
Advances in the comprehension of the bone healing and complications of the treatment of the fractures have been changed some concepts. Less invasive procedures have been advocated. A minimally invasive plate osteosynthesis (MIPO) is one of the best ways to avoid over tissue damage. The aim of this study was to evaluate the use of MIPO in tibial fractures in dogs. Ten dogs presenting a tibial fracture were used. Deambulation, swelling intensity and radiographic changes were evaluated preoperatively, just after the procedure and at 15, 30, 60, 90 e 120 days postoperatively. Six of 10 (60%) dogs were able to walk at 15 days postoperatively with slight swelling and mild lameness. Two of 10 (20%) presented normal walking at the same period. At 30 days postoperatively all dogs were able to walk normally. Six of them were not lame and 9 did not present swelling. Bone healing could be followed by radiographic evaluation. All dog presented initial radiographic signs of bone healing after 15 days postoperatively. Two of 10 showed clinical union at this time. In five of 10 (50%) clinical union could be observed after 60 days. The treatment of tibial fractures by MIPO is an effective alternative resulting in early and effective clinical union and can be performed without the use of image intensifiers
Asprino, Luciana 1974. "Comparação da resistencia ao carregamento de tres tecnicas de fixação interna rigida utilizadas no tratamento de fraturas condilares : estudo in vitro, em hemimandibulas de poliuretano." [s.n.], 2005. http://repositorio.unicamp.br/jspui/handle/REPOSIP/287882.
Full textTese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-04T05:16:45Z (GMT). No. of bitstreams: 1 Asprino_Luciana_D.pdf: 2820978 bytes, checksum: 12a98cf496579afbd3ea8036f938836c (MD5) Previous issue date: 2005
Resumo: O objetivo deste estudo foi avaliar comparativamente a resistência de três técnicas de fixação interna rígida com uso de mini placas em fratura de côndilo mandibular. Foram obtidas 80 réplicas de hemimandíbulas humanas em resina de poliuretano, sendo 20 do grupo controle. As 60 hemimandíbulas restantes foram submetidas a seccionamento simulando fratura subcondilar e em seguida fixadas com três técnicas da aplicação de placas e parafusos do sistema 2,Omm, que deram origem a seis grupos experimentais, cada um com 10 hemimandíbulas. As técnicas de fixação foram: uma placa de quatro furos com quatro parafusos de 6mm; uma placa de quatro furos com quatro parafusos de 8mm; e duas placas de quatro furos com quatro parafusos de 6mm cada. Cada sistema foi submetido ao teste de carregamento com aplicação de carga no sentido médiolateral e antero-posterior em máquina de ensaio universal Instron 4411. Foram mensurados valores de carga e deslocamento de pico. Médias e desvio padrão foram avaliados aplicando-se Análise de Variância (P<.05), verificada a significância estatística, aplicou-se o teste de Tukey com nível de significância de 5%. Tanto para o valor de carga como de deslocamento de pico, as hemimandíbulas fixadas com duas placas tiveram melhor comportamento, seguidas de uma placa com quatro parafusos de 8mm e uma placa com quatro parafusos de 6mm. Os sistemas de fixação aplicados foram mais resistentes ao carregamento no sentido antero-posterior e a aplicação de parafusos de 8mm aumentou a resistência da fixação comparado à aplicação de parafusos de 6 mm somente no teste antero-posterior. Pode-se concluir, dentro das condições testadas, que a utilização do sistema de fixação com a utilização de duas placas traz maior resistência à fixação aplicada às fraturas condilares. E, pode-se sugerir, que o uso de parafusos mais longos aumentaria a resistência da fixação aplicada à fratura de côndilo mandibular
Abstract: The aim of this study was to comparatively evaluate the resistance of three plating rigid internal fixation techniques for mandibular condylar process fractures. Eighty synthetic hemi-mandible replicas made in polyurethane were used to evaluate a control, and three mandibular condyle plating techniques using 2.0mm system plates and screws. The plating techniques were fixation with a four-hole plate and four 6-mm screws, fixation with a four-hole plate and four 8-mm screws and fixation with two four-hole plates with four 6-mm screws each. Each one was subjected to linear loading in medial to lateral and anterior to posterior directions by an Instron 4411 servo hydraulic mechanical testing unit. Load peak value and peak displacement were measured. Means and standard derivations were derived and compared for statistical significance using an analyses variance (P<.05) and compared by Tukey test. Statistically significant differences were noted between fixation groups for the different mechanical measures evaluated under the different directions of linear loading. The two-plate fixation system presented better behavior, followed by one plate with four 8-mm screws and one plate with four 6-mm screws. The employed fixation systems were more resistant to antero-posterior load and the use of 8-mm screws improved the resistance of the fixation when compared to 6-mm screws only in the antero-posterior test. Under the conditions tested the two-plate fixation system provided the most favorable mechanical behavior. We can suggest that lengthy screws can increase the stability at fixation of mandibular condylar process fractures
Doutorado
Cirurgia e Traumatologia Buco-Maxilo-Faciais
Doutor em Clínica Odontológica
Hedin, Hanne. "External Fixation of Femoral Fractures in Children : Clinical, radiological and functional outcome and cost analysis." Doctoral thesis, Uppsala University, Orthopaedics, 2003. http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-3322.
Full textThe overall aim of this thesis was to evaluate the outcome when treating children for displaced femoral fractures with external fixation.
In a consecutive and prospective study during the period 1993-2000, 96 children aged 3-15 years with 98 displaced femoral fractures were treated with external fixation and early mobilisation. The mean age was 8.1 years, the mean hospital stay was 8.7 days and the mean treatment time was 61 days. All fractures healed. Minor complications included pin tract infections (18%), clinical insignificant malunions, heterotopic ossification and two re-reductions. Major complications (6%) included two re-fractures after significant trauma and three plastic deformations after premature fixator removal leading to an osteotomy.
Radiological evaluation was performed up to one year for the whole group and for a subgroup up to two years. The evaluation showed that malunions were few and prone to remodelling almost completely. Although the fractures were fixated without shortening, as recommended earlier, the overgrowth was far less than expected.
Isokinetic muscle strength was measured in both hamstrings and quadriceps in 31 of the patients and compared with 31 matched children without previous injury to the legs. Early mobilisation seems to prevent residual muscle weakness previously shown after treatment with traction or cast for femoral fractures in children.
A cost analysis was performed, comparing three different treatment modalities of femoral shaft fractures: traction in hospital, traction in hospital/at home and external fixation. The analysis included both total medical costs and costs for the care provider. The most important factors were days spent at the hospital and the sick leave for the care provider. Treatment that can minimise these factors will contribute strongly to a lowering of health care costs.
Conclusion: External fixation of displaced femoral fractures in children can be used as standard treatment in children aged 3-15 years. The treatment provides satisfactory results with a low rate of major complications. Early mobilisation seems to prevent residual muscle weakness. The treatment reduce the number of days in hospital and the number of days of sick leave for the care provider and contributes strongly to lowering health care costs.
Vieira, e. Oliveira Thalita Regina 1981. "Fixação das fraturas da sífise mandibular = avaliação mecânica em mandíbulas de poliretano." [s.n.], 2011. http://repositorio.unicamp.br/jspui/handle/REPOSIP/310498.
Full textDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas
Made available in DSpace on 2018-08-17T14:31:09Z (GMT). No. of bitstreams: 1 Oliveira_ThalitaReginaVieirae_M.pdf: 1115745 bytes, checksum: 5dfbff585807258a186160f2079d47c9 (MD5) Previous issue date: 2011
Resumo: Este estudo teve como objetivo avaliar, comparativamente, o comportamento mecânico de quatro diferentes métodos de fixação de fraturas de sínfise mandibular. Quarenta réplicas de mandíbulas, confeccionadas em poliuretano, foram utilizadas para o ensaio experimental. As amostras foram divididas em quatro grupos com diferentes métodos de fixação: uma miniplaca, duas miniplacas dispostas paralelamente, duas miniplacas dispostas perpendicularmente e dois parafusos inseridos pela técnica lag screw, todos do sistema de 2,0mm. Cada grupo foi submetido ao teste mecânico em uma máquina de ensaio universal, Instron 4411 (Instron Corp, Norwood, MA), recebendo uma carga vertical linear na região do primeiro molar inferior esquerdo. Os valores das cargas foram mensuradas nos deslocamentos de 1 mm, 3 mm, 5 mm e 10 mm. Os resultados foram comparados por meio da Análise de Variância (p<0.05) e do Teste de Tukey. O método que utilizou uma miniplaca mostrou o menor valor de resistência, quando comparado aos outros métodos de fixação. A técnica lag screw apresentou resistência estatisticamente maior que as duas placas paralelas, em todos os deslocamentos. As duas miniplacas perpendiculares mostraram menor resistência que a técnica lag screw, quando o deslocamento atingiu 1 e 3 mm e resistência estatisticamente semelhante nos deslocamentos de 5 e 10 mm. Entretanto, as duas miniplacas perpendiculares não apresentaram diferença estatisticamente significante em relação ao grupo das duas miniplacas paralelas. Desta forma, a técnica lag screw apresentou melhor comportamento mecânico para a fixação das fraturas de sínfise mandibular, que os demais métodos avaliados neste estudo
Abstract: The aim of this study was to evaluate comparatively the mechanical behavior of 4 different internal fixation methods for mandibular symphysis fractures. Forty polyurethane mandible replicas were used. They were divided in to four groups with different fixation methods: 1 miniplate, 2 parallel miniplates, 2 perpendicular miniplates, 2 lag screws, all of them of a 2.0mm system. Each group was subjected to linear vertical loading at the molar region by an Instron 4411 servohydraulic mechanical testing unit (Instron Corp, Norwood, MA). Load values were measured at 1 mm, 3 mm, 5 mm, and 10 mm of displacement. Means and standard derivations were compared for statistical significance using a variance analysis (p < .05) and compared by the Tukey test. The one 2.0-mm miniplate showed the lowest load scores when compared with other fixation methods. The two 2.0-mm lag screw technique showed higher resistance statistically significant in comparison with two 2.0-mm parallel miniplates for all displacements. The two 2.0-mm perpedicular miniplates showed lower resistance than two 2.0-mm lag screw technique when the displacement was 1 and 3 mm, and statiscally similar results at 5 and 10 mm of displacement. However, the two 2.0-mm perpendicular miniplates group was not statiscally different from the two 2.0-mm parallel miniplates group. The lag screw technique showed better mechanical behavior for fixation of symphyseal fractures than the other methods when subjected to linear vertical loading at the molar region
Mestrado
Fisiopatologia Cirúrgica
Mestre em Ciências
Yamamoto, Marcos Kazuo. "Necessidade de reabordagem cirúrgica após tratamento de fraturas mandibulares por fixação interna rígida." Universidade de São Paulo, 2010. http://www.teses.usp.br/teses/disponiveis/23/23149/tde-18112010-124009/.
Full textMandibular fractures are frequent and their treatment is through rigid internal fixation (RIF). Complications can occur after treatment of the mandibular fractures which may require a new surgical procedure, and there are a few studies about that in the literature. The purpose of this retrospective study was to evaluate the characteristics, possible risk factors, and the kinds of treatment did in patients which needed another surgery after treatment of mandibular fracture with RIF. From 364 patients with mandibular fractures treated by RIF, there were 17 patients (4.7%) with need of a new surgery, and 3 patients coming from another city were included, comprising a total of 20 patients who needed a new surgery. There was predominance of the male gender, with a mean age of 31.4 years, being frequent smoking and alcohol abuse. Multiple and comminuted fractures on the body and angle sites, teeth in the fracture line, and intraorally exposed fractures were frequent. Delay time to the first surgery was high, and extraoral approaches and system 2.0mm were predominant. The most common complications were pain, infection and abnormal mobility. In the bacterial culture there was predominance of Staphylococcus aureus, and the most frequent radiographic images were of diffuse bone resorption, loosening of screws, bone sequestration, fracture line visible, loose fixation, and fractured plate. A new surgery occurred with a mean of 7.5 months after the first intervention and comprised plate and screws removal associated or not to a new fixation or bone sequestra removal, and only a case the fracture needed to be osteotomized. Histologically there was predominance of chronic osteomyelitis. The diagnoses in decreasing order were infection, nonunion, osteomyelitis and exposed plate, although many patients had more than one diagnosis. It was evidenced the frequency of smoking and alcohol abuse, multiple and comminuted fracture on the body and angle regions, teeth in the fracture line, intraoral fracture exposition, high delay time and extraoral approaches predisposing complications of the mandibular fractures, and images showing bony resorption, loose hardware and bone sequestra, as well as histological diagnosis of osteomyelitis as characteristic of the cases requiring a new surgery.
Oliveira, Kerlison Paulino de. "Avalia??o mec?nica in vitro utilizando miniplacas quadradas e retangulares do sistema 2.0 mm em fraturas da regi?o anterior de mand?bula." Universidade Federal do Rio Grande do Norte, 2012. http://repositorio.ufrn.br:8080/jspui/handle/123456789/17806.
Full textThe aim of this study was to comparatively evaluate the mechanical strength of squared and rectangular 2.0 mm system miniplates comparing them to the standard configuration with 2 straight miniplates in stabilizing fractures in the anterior mandible. Ninety synthetic polyurethane mandible replicas were used in mechanical test. The samples were divided into six groups of three different methods for fixation. Groups 1, 2 and 3 showed complete fractures in symphysis, characterized by a linear separation between the medial incisor, and groups 4, 5 and 6 showed complete fractures in parasymphysis with oblique design. Groups 1 and 4 were represented by the standard technique with two straight miniplates parallel to each other. Groups 2 and 5 were stabilized by squared miniplates and groups 3 and 6 were fixed by rectangular design. Each group was subjected to a mechanical test at a displacement speed of 10 mm/min on a universal testing machine, receiving linear vertical load on the region of the left first molar. The values of the maximum load and when displacements reached 5 mm were obtained and statistically analyzed by calculating the confidence interval of 95%. Fixation systems using squared (G2) and rectangular (G3) miniplates obtained similar results. No statistically significant differences with respect to the maximum load and the load at 5 mm displacement were found when compared to standard method in symphyseal fractures (G1). In parasymphysis the fixation method using squared miniplates (G5) obtained results without significant differences regarding the maximum load and the load at 5 mm when compared to the standard configuration (G4). The fixation method using rectangular miniplates (G6) showed inferior results which were statistically significant when compared to the standard configuration (G4) for parasymphysis fractures. The mechanical behavior of the fixation methods was similar, except when rectangular miniplates were used. The fixation methods showed better results with statistical significance in symphyseal fractures
O prop?sito deste estudo foi avaliar comparativamente a resist?ncia mec?nica de miniplacas quadradas e retangulares do sistema 2.0 mm, comparando-as ? configura??o padr?o, com 2 miniplacas retas, na estabiliza??o de fraturas na regi?o anterior de mand?bula. Noventa r?plicas de mand?bulas de poliuretano foram utilizadas no ensaio mec?nico. As amostras foram divididas em 6 grupos com 3 m?todos de fixa??o do sistema 2.0 mm. Os grupos 1, 2 e 3 apresentavam fraturas sinfis?rias completas, caracterizadas pela separa??o linear entre os incisivos mediais, e os grupos 4, 5 e 6 apresentavam fraturas parassinfis?rias completas com desenho obl?quo. Os grupos 1 e 4 foram representados pelo m?todo padr?o, com 2 miniplacas retas, dispostas paralelamente entre si. Os grupos 2 e 5 tiveram as mand?bulas estabilizadas por meio de miniplacas quadradas e os grupos 3 e 6, pelas retangulares. Cada grupo foi submetido a um teste mec?nico realizado por meio de uma m?quina de ensaio universal, na velocidade de 10mm/minuto, recebendo carga vertical linear na regi?o de primeiro molar esquerdo. Os valores da carga m?xima e da carga com deslocamento pr?-estabelecido em 5 mm foram obtidos e submetidos ? an?lise estat?stica a partir do c?lculo do intervalo de confian?a de 95%. Os sistemas de fixa??o utilizando miniplacas quadradas (G2) e retangulares (G3) obtiveram resultados similares, sem diferen?as estatisticamente significativas em rela??o ? carga m?xima e ? carga no deslocamento de 5 mm, quando comparada ? configura??o padr?o (G1), nas fraturas sinfis?rias da mand?bula. Nas fraturas parassinfis?rias, o m?todo de fixa??o utilizando miniplacas quadradas (G5) obteve resultados sem diferen?as estatisticamente significativas no que se refere ? carga m?xima e ? carga no deslocamento de 5 mm, quando comparadas ? configura??o padr?o (G4). O m?todo de fixa??o utilizando as miniplacas retangulares (G6) obteve resultados inferiores, estatisticamente significantes, quando comparado ? configura??o padr?o (G4) nas fraturas parassinfis?rias. O comportamento mec?nico dos m?todos de fixa??o estudados foi similar, exceto nas fraturas parassinfis?rias, quando se utilizaram as miniplacas com a configura??o retangular. Os m?todos de fixa??o utilizados apresentaram melhores resultados, com signific?ncia, nas fraturas sinfis?rias
Zacharias, Stephanie Cabral. "Clínica e cirurgia de equinos." Master's thesis, Universidade de Évora, 2016. http://hdl.handle.net/10174/19249.
Full textLanka, Gopi Krishna. "Stability of the Mandible–Strut Plate Complex in Isolated Angle Fractures: A Finite Element Study." University of Cincinnati / OhioLINK, 2018. http://rave.ohiolink.edu/etdc/view?acc_num=ucin1535382405124984.
Full textFigueiredo, Adriana Valente de. "Estudo biomecânico ex vivo em coluna tóraco-lombar de cães com técnicas de estabilização utilizando Placa Bloqueada, Clamp Rod Internal Fixation, Pino com Cimento Ósseo e Técnica Segmentar Modificada." Universidade de São Paulo, 2013. http://www.teses.usp.br/teses/disponiveis/10/10137/tde-20082014-145759/.
Full textSpinal fractures and luxations resulting from trauma consist frequent disorder in clinical veterinary practice, being thoracolumbar spine the region that is the most commonly affected in canines, thus in many cases surgical treatment is necessary. There are several proposed techniques of implants to perform spinal stabilization; however, few studies of the thoracolumbar spine were carried out to evaluate the biomechanical properties of each technic. Therefore, the objective of the present study is to analyze biomechanical effects comparing the strength and the stiffness promoted by five different technics of stabilization in the thoracolumbar spine (pin with bone cement, modified segmental stabilization, locking plate and clamp rod internal fixation) under compression and bending forces. In the study, thirty four thoracolumbar dog spines were used, dividing the specimens in five groups. In order to perform the biomechanical tests, it was used a Kratos testing machine (model KE3000MP) and loading cell of 100 Kg. Each body of proof was submitted to three biomechanical tests, the control, in the segment intact, after disarticulation of the T13/L1 and after the realization of one of the proposed technics. Data were exported to statistical analyses to the Statistical Package for the Social Sciences (SPSS) version 18.0. The results led to the conclusion that despite there was no statistically significant difference between the techniques, the Locking Plate was the technique that promoted greater rigidity and stability in the injured vertebrae, followed by the Clamp Rod Internal Fixation bicortical, Modified Segmental Instrumentation and Pins with Bone Cement. Statistically, the locking plate and the Clamp Rod Internal Fixation with bicortical pins showed more stiffness and stability in T13/L1 when compared to the Clamp Rod Internal Fixation monocortical, which did not achieved the adequate rigidity for the stabilization of the vertebrae.
Benegas, Eduardo. "Estudo comparativo entre a haste intramedular bloqueada e a placa em ponte no tratamento cirúrgico das fraturas da diáfise do úmero." Universidade de São Paulo, 2008. http://www.teses.usp.br/teses/disponiveis/5/5140/tde-12022009-130247/.
Full textThe purpose of the study is to compare clinical and radiographic outcomes between nonreamed locked intramedullary nail and bridging plate for the treatment of humeral shaft fracture. Forty humeral shaft fractures in 39 patients, A, B or C AO types were treated between June 2003 and December 2007. The cases were randomly assigned into two groups being 21 fractures fixed by a 4.5 mm bridging plate, and 19 by nonreamed intramedullary locking nail. Two cases had open fractures, one Gustilo type II, the other type IIIa. Twenty five patients were male (64%), ages ranging from 19 to 75 years old (mean age 41 years and 10 months). The right side was treated in 22 patients (55%) and fall was the most frequent cause of fracture (46%). The minimal period of follow-up was six months and the maximum was 60 months for the bridging plate group (mean=34.5 months) and ranged from eight to 58 months (mean=27months) for the nail group. Only one case from the nail group presented a nonunion. One case, in the plate group, developed a deep infection, and another one, in the nail group, had a superficial infection. Two cases of the bridging plate group had adhesive capsulites and in one case of the nail group the distal screw became prominent. A transient neuropraxis of the antebrachial lateral cutaneous nerve was found in one case of the nail group, but it recovered in three days. There were no differences between the groups concerning pain, function, active flexion and strength of flexion of the shoulder, as well as pain, range of motion, muscle strength, and stability of the elbow. According to the UCLA score, we had 85.7% excellent and good results in the plate group and 79% in the nail group. According to Broberg and Morrey score for the elbow, we had 85.7% excellent and good results in the plate group and 90.5% in the nail group. Just one patient, from the nail group, was not satisfied with the final result, according to subjective criteria. In conclusion, there were no differences in the final clinical and radiographic results between the two methods of fixation
Goulart, Douglas Rangel 1987. "Development of plate of osteosynthes for mandibular angle fracture with boné loss = finite elemento analysis and mechanical test = Desenvolvimento de placa de fixação interna para o tratamento de fratura complexa de ângulo mandibular: avaliação pelo método dos elementos finitos e teste mecânico." [s.n.], 2014. http://repositorio.unicamp.br/jspui/handle/REPOSIP/287887.
Full textDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-08-24T09:12:42Z (GMT). No. of bitstreams: 1 Goulart_DouglasRangel_M.pdf: 2699898 bytes, checksum: e7d2281b73e4ff46b282bf86177c5b1a (MD5) Previous issue date: 2014
Resumo: Apesar da evolução do tratamento das fraturas de ângulo mandibular, o conhecimento torna-se restrito quando se trata de fraturas com múltiplos traços ou perda de estrutura óssea, devido à falta de investigações específicas na área. Dessa forma, o objetivo desse trabalho é desenvolver e avaliar um novo design de placa de fixação interna para tratamento de fraturas complexas de ângulo mandibular por meio do método dos elementos finitos e teste de carregamento linear. Primeiramente foi gerado um modelo tridimensional da mandíbula fraturada no software Rhinocerus 4.0, seguida pela modelagem de placas e parafusos do sistema 2,0 mm. Os modelos foram exportados para o Ansys®, no qual foi aplicado deslocamento de 3 mm no rebordo alveolar na região que corresponde a fossa central do primeiro molar ipsilateral a fratura. Foram avaliados três grupos segundo o método de fixação interna: duas placas do sistema 2,0 mm; duas placas do sistema 2,0 mm locking; e uma placa com novo design do sistema 2,0 mm locking. O modelo computacional foi transferido para um modelo in vitro com mandíbulas de poliuretano, com os mesmos grupos de fixação e padrão de fratura mandibular. Cada grupo foi composto por cinco mandíbulas, cada amostra foi submetida ao teste de carregamento linear na máquina de ensaio universal Instron modelo 4411 até o deslocamento de 5 mm. Para o modelo computacional foi observada uma distribuição mais equilibrada de tensão no novo design de placa, além disso, a fixação com a nova placa apresentou uma tendência de manter os segmentos aproximados. Porém foi observada superioridade da força de reação do grupo com duas placas 2,0 mm locking (651,67 N). No ensaio mecânico o grupo com duas placas locking apresentou maior resistência ao deslocamento de 3 mm com diferenças estatisticamente significativa que o grupo da nova placa (one-way ANOVA; F = 4,92, p = ,013). Foi desenvolvido um modelo de placa para o tratamento de fratura de ângulo mandibular, que na análise de elementos finitos apresentou uma distribuição mais equilibrada das tensões, porém o grupo com duas placas locking apresentou maior resistência mecânica. A nova placa pode substituir duas placas convencionais sem prejuízo de resistência mecânica e com vantagens de apresentar a tendência de manter os segmentos fraturados aproximados quando submetidos a deslocamento
Abstract: Despite the developments concerning the treatment of mandibular angle fractures, knowledge becomes limited when it comes to multiple fractures lines or loss of bone due to the lack of specific investigation in this field. Thus, the aim of this work is developing and evaluating a new design of internal fixation plate for the treatment of the complex mandibular fractures by the finite element method and mechanical testing. A three dimensional model of the fractured mandible was generated in Rhinocerus 4.0 software, and also was performed the modeling of the 2.0 mm system plates. The models have been exported to ANSYS ®, in which it was performed a static application of a force to generate displacement of 3 mm in the first molar region ipsilateral to the fracture. Three groups were evaluated according to the method of internal fixation: two plates of the 2.0 mm non-locking system, two plates of 2.0 mm locking system, and a plate with new design 2.0mm locking system. The computational model was transferred to an in vitro experiment with polyurethane mandibles with the same fixation groups and fracture pattern. Each group with five mandibles was subjected to linear loading test in a universal testing machine Instron Model 4411 to the displacement of 5 mm. A more balanced distribution of stress in the new plate design was observed. In addition, the new plate modified the mechanical behavior of the fractured region with a tendency to keep the approximate segments. However, the superiority of the reaction force of the group with two 2.0mm locking plates was observed (651.67 N). In the mechanical test the group with two locking plates showed greater resistance to the 3 mm displacement with statistically significant difference than the new plate group ( one-way ANOVA , F = 4.92 , p = 013)
Mestrado
Cirurgia e Traumatologia Buco-Maxilo-Faciais
Mestre em Clínica Odontológica