To see the other types of publications on this topic, follow the link: Gas compressor station.

Journal articles on the topic 'Gas compressor station'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 journal articles for your research on the topic 'Gas compressor station.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse journal articles on a wide variety of disciplines and organise your bibliography correctly.

1

Kryshtopa, S. I., L. I. Kryshtopa, M. М. Hnyp, I. M. Mykytiy, and M. M. Tseber. "Development of energy efficient system of gas cooling of mobile diesel compressor stations of oil and gas industry." Oil and Gas Power Engineering, no. 1(33) (September 3, 2020): 81–89. http://dx.doi.org/10.31471/1993-9868-2020-1(33)-81-89.

Full text
Abstract:
The developments of domestic and foreign specialists in the field of improving the energy efficiency of mobile diesel compressor stations of the oil and gas industry is studied. The disadvantages of existing mobile diesel compressor stations in terms of their energy efficiency are identified. Theoretical studies of energy efficiency directions and designs of existing mobile diesel compressor stations have been carried out. It has been studied that for efficient operation of a compressor station it is rational to increase the load of compressors and organize the operation of equipment in energy
APA, Harvard, Vancouver, ISO, and other styles
2

Maria Gligor, Alina. "Considerations on the automation of a natural gas compressor station." MATEC Web of Conferences 184 (2018): 03007. http://dx.doi.org/10.1051/matecconf/201818403007.

Full text
Abstract:
Natural gas compressor stations are very important components of a natural gas life cycle. Unfortunately, in Romania most of the existing natural gas compressor stations are equipped only with old-type automation systems, with a high degree of physical and moral wear. The current paper describes the main elements and functions of an automation system that was implemented in a natural gas compressor station, offering an improved pressure control function, but also the possibility to control the compressors from a distance, for example from a central dispatching station.
APA, Harvard, Vancouver, ISO, and other styles
3

Kurz, Rainer, Matt Lubomirsky, and Klaus Brun. "Gas Compressor Station Economic Optimization." International Journal of Rotating Machinery 2012 (2012): 1–9. http://dx.doi.org/10.1155/2012/715017.

Full text
Abstract:
When considering gas compressor stations for pipeline projects, the economic success of the entire operation depends to a significant extent on the operation of the compressors involved. In this paper, the basic factors contributing to the economics are outlined, with particular emphasis on the interaction between the pipeline and the compressor station. Typical scenarios are described, highlighting the fact that pipeline operation has to take into account variations in load.
APA, Harvard, Vancouver, ISO, and other styles
4

Caryana, Yusep K. "An Indonesian Experience, Consumers’ Demand For Cng Compression Facilities Performance." Scientific Contributions Oil and Gas 21, no. 1 (1998): 9–15. http://dx.doi.org/10.29017/scog.21.1.950.

Full text
Abstract:
Compressed Natural Gas (CNG) has been used to fuel vehicles in many countrie, including in Indonesia. However, there are many difficulties to overcome in CNG public acceptance. In Indonesia, one of these may be CNG consumer’s preference for certain CNG refuelling stations over others. Finding causes of this may help increase acceptance of CNG by Indonesian motorists and enable CNG to make a better contribution to achievingthe country’s energy diversification policy. It is hypothesized that the variation in intake pressures at CNG station to be a cause for preference by CNG consumers. This hypo
APA, Harvard, Vancouver, ISO, and other styles
5

Kryzhanivskyy, Ye I., V. Ya Grudz, V. Ya Grudz (jun.), R. B. Tereshchenko, and R. M. Govdjak. "OPTIMIZING THE MODES OF COMPRESSOR STATIONS UNDER THE CONDITIONS OF THEIR PARTIAL LOAD." Oil and Gas Power Engineering, no. 1(31) (June 26, 2019): 36–42. http://dx.doi.org/10.31471/1993-9868-2019-1(31)-36-42.

Full text
Abstract:
The principle of construction of stochastic and deterministic mathematical models for prediction of operating modes of gas pumping units at compressor stations of main gas pipelines and their optimization in conditions of incomplete loading of the gas transmission system is proposed. Calculation of the parameters of the technological mode of operation of the compressor stations of gas pumping units is based on the use of combined characteristics of centrifugal superchargers, the processing of which by means of mathematical statistics allowed to obtain analytical expressions for the characteris
APA, Harvard, Vancouver, ISO, and other styles
6

Gulbala Alasgarov, Gulbala Alasgarov, Alovsat Baghirov Alovsat Baghirov, and Shahriyar Baghirov Shahriyar Baghirov. "DIAGNOSTICS OF THE OPTIMAL OPERATING MODES OF GAS TURBINE COMPRESSOR STATIONS BASED ON THE ANALYSIS OF TECHNOLOGICAL PROCESSES." PAHTEI-Procedings of Azerbaijan High Technical Educational Institutions 12, no. 01 (2022): 14–28. http://dx.doi.org/10.36962/pahtei1201202214.

Full text
Abstract:
The article is dedicated to the analysis of the influence of the seasonally changing ambient temperature on the technological parameters of the compression process at a gas turbine compressor station for the transportation of natural and associated gas collected from oil and gas fields by an offshore subsea gas pipeline. As a result of the analysis, indicators of suction and discharge pressure, compressor capacity, ambient temperature during the summer and winter months were collected at each stage of a multi-unit two-stage compressor station. The indicators were divided into intervals, the nu
APA, Harvard, Vancouver, ISO, and other styles
7

Vanyashov, A. D., V. V. Karabanova, and A. A. Nefedov. "Evaluation of the prospects for the use of single-stage centrifugal compressors based on high-pressure stages with an inlet guide device at linear gas compressor stations." Omsk Scientific Bulletin. Series Aviation-Rocket and Power Engineering 8, no. 3 (2024): 36–45. http://dx.doi.org/10.25206/2588-0373-2024-8-3-36-45.

Full text
Abstract:
The issues of evaluating the technical and economic prospects for the use of gas pumping units with single-stage centrifugal compressors with an axial suction nozzle, created on the basis of high-pressure stages with axial impellers and an adjustable inlet guide device, at linear gas compressor stations are considered. A brief description of the methodology for recalculating tests of a small compressor stage performed in air for working conditions as part of a gas compressor station is given. A comparative assessment of the competitiveness of the proposed compressor type with existing types of
APA, Harvard, Vancouver, ISO, and other styles
8

Zhussupova, Dinara, Mukhtarbay Otelbaev, and Saule Burgumbayeva. "Modeling Gas Compressor Station Operation to Minimize Fuel Costs for Surge Zone Protection." International Journal of Rotating Machinery 2024 (March 15, 2024): 1–18. http://dx.doi.org/10.1155/2024/5560308.

Full text
Abstract:
Gas transportation through the pipeline network requires high pressure; otherwise, movement will be impossible. Due to friction with the walls of the pipes, the gas loses both speed and pressure. Therefore, it is necessary to increase the pressure in the main pipeline, which can extend for thousands of kilometers. For this purpose, compressor stations are located along the main network, facilitating the gas transport process by raising it to the required pressure. Compressor stations mainly consume the transported gas, with approximately 5% expended on gas compression. This article presents a
APA, Harvard, Vancouver, ISO, and other styles
9

BASKANBAYEVA, D. D., K. K. YELEMESSOV, L. B. SABIROVA, and N. K. AUBAKIROVA. "INTEGRATION OF SAFETY AND EFFICIENCY OF COMPRESSOR UNITS IN PETROLEUM INDUSTRIAL ENVIRONMENTS." Neft i Gaz 144, no. 6 (2024): 48–63. https://doi.org/10.37878/2708-0080/2024-6.05.

Full text
Abstract:
In this article, the analysis of safety, reliability and efficiency indicators of compressor units according to operating data was carried out. The disadvantages of a commercial nature are revealed, for example, the degree of compressor loading depending on the location of the CNG station, hindering business development. Then the analysis of technical characteristics is carried out, the task is formulated and the most acceptable way of its organizational and technical solution is found. Kazahstan buys compressors for natural gas compression abroad, so, among other things, we are talking about
APA, Harvard, Vancouver, ISO, and other styles
10

Berdnik, A. N. "IMPROVEMENT OF THE AIR-CLEANING DEVICE OF THE GAS TURBINE INSTALLATION OF THE COMPRESSOR STATION OF THE MAIN GAS PIPELINE." Spravochnik. Inzhenernyi zhurnal, no. 312 (March 2023): 3–7. http://dx.doi.org/10.14489/hb.2023.03.pp.003-007.

Full text
Abstract:
Presented a various types of pollution of compressed air at the entrance to the combustion chamber of a gas turbine installation depending on the geographical location of the compressor station of the main gas pipeline. Shown is a comparison of technical and economic indicators of two design schemes of air-purifying devices of a gas turbine installation at the compressor station of the main gas pipeline.
APA, Harvard, Vancouver, ISO, and other styles
11

Abbaspour, M., K. S. Chapman, and P. Krishnaswami. "Nonisothermal Compressor Station Optimization." Journal of Energy Resources Technology 127, no. 2 (2004): 131–41. http://dx.doi.org/10.1115/1.1871248.

Full text
Abstract:
A detailed mathematical model of compressor stations and pipes is essential for optimizing the performance of the gas pipeline system. Most of the available literature on compressor station modeling is based on isothermal solutions for pipe flow, which is inadequate for our purposes. In the present work, the pipe flow is treated as nonisothermal unsteady one-dimensional compressible flow. This is accomplished by treating the compressibility factor as a function of pressure and temperature, and the friction factor as a function of Reynolds number. The solution method is the fully implicit finit
APA, Harvard, Vancouver, ISO, and other styles
12

Rauf Huseynli, Rauf Huseynli. "PURPOSE AND DESCRIPTION OF THE COMPRESSOR STATION." PAHTEI-Procedings of Azerbaijan High Technical Educational Institutions 06, no. 02 (2021): 53–57. http://dx.doi.org/10.36962/pahtei0602202153.

Full text
Abstract:
All work on the construction of pumping and compressor stations is usually divided into two groups of zero cycle work and ground cycle work. The work of the zero cycle includes the preparation of the construction site, earthworks, work on the construction of foundations for buildings, pumping units and technological equipment, work on the construction of underground pipelines and utilities. The work of the ground cycle includes work on the construction of buildings for pumping and compressor shops and auxiliary buildings, installation work on installation and fixing on the foundations in the d
APA, Harvard, Vancouver, ISO, and other styles
13

Sebuhi Ahmedov, Aslan Yusifli, Sebuhi Ahmedov, Aslan Yusifli. "OPTIMIZATION SYSTEM FOR LOCAL CONTROL OF COMPRESSOR STATION." PAHTEI-Procedings of Azerbaijan High Technical Educational Institutions 44, no. 09 (2024): 05–09. http://dx.doi.org/10.36962/pahtei44092024-01.

Full text
Abstract:
The article was devoted to the characteristics of using a compressor to process gas deposits. It is an important principle that the liquid is lifted to the surface of the earth by the energy of the gas compressed from the layer during processing. The structure of the well, the diameter of the exploitation belt, and the fountain pipes should be determined in such a way that there is little pressure in the well and in the trunk. Fountain pipes should not be lowered from the barrier to reducing pressure in the well's trunk and saving metal consumption. Depending on the daily gas volume of oil dep
APA, Harvard, Vancouver, ISO, and other styles
14

Natig, Sabir Seyidahmadov. "METHODOLOGY OF EXPERIMENTAL INVESTIGATIONS OF VALVE OPERATION." EUREKA: Physics and Engineering 5 (September 30, 2019): 56–63. https://doi.org/10.21303/2461-4262.2019.00991.

Full text
Abstract:
Tightness, as well as the reliability of the valve plate, is a complex property of the effective operation of compressor cylinders of the first stage and, in general, gas-engine reciprocating compressors. The issue of valve plate tightness is a subject of independent study, since technical and economic efficiency depends on their work. In this connection, only some data obtained under operating conditions are presented in this work. As a research result, it is found that, taking into account the identified requirements for the gas lift system, in order to effectively increase the operating hou
APA, Harvard, Vancouver, ISO, and other styles
15

Vorontsov, M. A., V. Yu Glazunov, A. S. Grachev, M. S. Mashtalir, S. A. Pospelov, and A. V. Chernyshev. "Comparison of methods for modeling the gas-dynamic characteristics of high-pressure centrifugal compressors that ensure the operation of field low-temperature separation units using the example of a modification with a pressure ratio of up to 1.9...2.1." Herald of Dagestan State Technical University. Technical Sciences 51, no. 3 (2024): 6–14. http://dx.doi.org/10.21822/2073-6185-2024-51-3-6-14.

Full text
Abstract:
Objective. Currently, for the development of Valanginian and other deeplying (compared to the Cenomanian) deposits, low-temperature separation (LTS) units with turboexpander units (TDA) are used, and the booster compressor station (BCS) is one of the key technological facilities necessary to ensure the efficient operation of promising technologies for gas preparation using the NTS method with TDA turboexpander units for transport. The purpose of the study is to substantiate optimal operating modes, as well as to develop measures for the technological development of a booster compressor station
APA, Harvard, Vancouver, ISO, and other styles
16

Kalashnikov, Dmitriy, Yuriy Borisov, and Elizaveta Kalashnikova. "Natural gas intracyclic attachment for energy generating unit based on gas turbine plant." E3S Web of Conferences 114 (2019): 06004. http://dx.doi.org/10.1051/e3sconf/201911406004.

Full text
Abstract:
In this article, problems of effectiveness increasing in complex power supply are considered. Disadvantages of centralized power engineering and advantages of power engineering capabilities organization in immediate consumer proximity are presented. Consumer needs satisfaction in electricity, heat supply and cold supply are offered to be realized by conversion of district and quarter boiler houses to trigeneration stations, which are based on gas turbine plants units. In this research, solutions of problem related to lack of fuel gas pressure for gas turbine engine power, which is included in
APA, Harvard, Vancouver, ISO, and other styles
17

Brezean, Octavian Andrei. "Increase efficiency and process optimization for an existing gas compressor station unit in Oil and Gas industry." IOP Conference Series: Earth and Environmental Science 968, no. 1 (2022): 012001. http://dx.doi.org/10.1088/1755-1315/968/1/012001.

Full text
Abstract:
Abstract As most gas compression facilities in Romania are from the 60’s-80, there is an increased demand to increase their efficiency. The paper explains researches on energy, economic and functional efficiency of equipment and processes during the modernization of a compressor station in oil and gas industry. It is meant to serve as a general guide for methods and procedures usually used in the industry in Romania, to improve the efficiency of an existing compressor station.
APA, Harvard, Vancouver, ISO, and other styles
18

Asihono, Panglima Machmud Subarkah, and Nur Budi Mulyono. "Maintaining the Reliability of Production Facilities in Operation Management of Upstream Oil and Gas Industries: Case Study at GNK Gas Compression Station PT. PEP ZONA 4." European Journal of Business and Management Research 8, no. 2 (2023): 154–62. http://dx.doi.org/10.24018/ejbmr.2023.8.2.1858.

Full text
Abstract:
PT PEP as an upstream energy company has the vision to become a world-class energy company. It has a mission to run oil, gas, and new and renewable energy businesses in an integrated manner, based on strong commercial principles. GNK Gas Compression Station is one of the production facilities incorporated in the work area of PT PEP where the station receives gas from GNK 3 Block Station, GNK 2 Block Station, and GNK 1 Block Station.GNK Gas Compression Station consists of several pieces of production equipment which is aging facilities with a minimalist design that adapts to the needs of the fi
APA, Harvard, Vancouver, ISO, and other styles
19

S, Owhor B., Ossia C. V, and Aikhuele D. O. "Reliability Analysis of Gas Compressing System Using Cumulative Distribution Functions." Saudi Journal of Civil Engineering 9, no. 03 (2025): 80–86. https://doi.org/10.36348/sjce.2025.v09i03.004.

Full text
Abstract:
This study evaluated the reliability of natural gas compressing system at Soku and Obigbo gas stations over a period of 4 years. Historical failure data of the compressing system at the gas stations were evaluated using exponential cumulative distribution function (ECDF) and Weibull cumulative distribution function (WCDF) to analyze the compressors reliability. The mean time between successive maintenance at the gas stations occurred within a short interval. This implies a high frequency of failures of the compressing system. The WCDF and ECDF established that the reliability of the gas compre
APA, Harvard, Vancouver, ISO, and other styles
20

Azka Roby Antari and Zulfan Yusuf Asdan. "ANALISIS KENDALA OPERASIONAL PADA KOMPRESOR SKG X MILIK PT. P PRABUMULIH PADA PERIODE APRIL 2018 – MARET 2019." Jurnal Cakrawala Ilmiah 3, no. 2 (2023): 499–516. http://dx.doi.org/10.53625/jcijurnalcakrawalailmiah.v3i2.6725.

Full text
Abstract:
The gas compressor engine is the main equipment at the Gas Compressor Station (SKG). The working principle is gas compression, the compressor has rotating impeller blades pushing the gas into the diffuser forcing the gas to move into the vessel until the pressure on the gas increases. At SKG X PT. P Prabumulih who supplies gas to PT. Pusri, there are 4 compressor units (A, B, C, D), where in one day three compressor units are operating, and one compressor unit is in stand-by condition or under maintenance so it does not operate. The total operating hours of all compressors in one day is 72 hou
APA, Harvard, Vancouver, ISO, and other styles
21

O, Zaporozhets, Karpenko S, Puzik S, and Sagaidak B. "MODEL OF SOUND LEVELS CALCULATION FOR NOISE FROM COMPRESSOR STATIONS FOR JUSTIFICATION OF SANITARY PROTECTION ZONE BOUNDARIES." National Transport University Bulletin 1, no. 50 (2021): 81–91. http://dx.doi.org/10.33744/2308-6645-2021-3-50-081-091.

Full text
Abstract:
This article is devoted to the study of sound levels for noise from a gas turbine plant and technological equipment of a compressor station in everyday operation, in order to assess the sustainability of the conditions of sanitary protection zones around the compressor station and in order to protect the population living near the compressor station. The main purpose of the study is to assess the compliance of the sizes of sanitary protection zones in terms of noise load on environment. The main source of noise at compressor gas-pumping stations is determined by the noise regime at the industr
APA, Harvard, Vancouver, ISO, and other styles
22

Kowalski, Rafał, Szymon Kuczyński, Mariusz Łaciak, Adam Szurlej, and Tomasz Włodek. "A Case Study of the Supercritical CO2-Brayton Cycle at a Natural Gas Compression Station." Energies 13, no. 10 (2020): 2447. http://dx.doi.org/10.3390/en13102447.

Full text
Abstract:
Heat losses caused by the operation of compressor units are a key problem in the energy efficiency improvement of the natural gas compression station operation. Currently, waste heat recovery technologies are expensive and have low efficiency. One of these technologies is organic Rankine cycle (ORC) which is often analyzed in scientific works. In this paper, the authors decided to investigate another technology that allows for the usage of the exhaust waste energy—the supercritical Brayton cycle with CO2 (S-CO2). With a thermodynamic model development of S-CO2, the authors preformed a case stu
APA, Harvard, Vancouver, ISO, and other styles
23

Song, Ying, Liang Feng, and Wenchen Cao. "Discussion on operation flexibility of Zhonggui natural gas pipeline." E3S Web of Conferences 300 (2021): 01015. http://dx.doi.org/10.1051/e3sconf/202130001015.

Full text
Abstract:
Zhongwei station of West to east natural gas pipeline is connected to the north of Zhonggui line, and Guiyang station of China-Myanmar natural gas pipeline is connected to the south, which has important strategic significance in Southwest China. At present, the tie line mainly carries out gas transmission from Zhongwei to Guiyang. Only some pipeline sections and offload stations have reverse transmission function, while all compressor stations have no reverse transmission and pressurization function. In order to evaluate the flexibility of the operation of the Zhonggui line and give some sugge
APA, Harvard, Vancouver, ISO, and other styles
24

Aygun, Safarova Agamirza, and İslmayilova Maleyka. "DEVELOPMENT OF MATHEMATICAL MODEL FOR GAS COMPRESSOR STATIONS." Annali d'Italia 66 (April 29, 2025): 94–97. https://doi.org/10.5281/zenodo.15303127.

Full text
Abstract:
A gas compressor station is a station whose main task is to increase the pressure of natural gas. This is done both during its production and during transportation and storage. At the same time, it is necessary to constantly maintain a given value of the discharge pressure, taking into account the main parameters that affect the operation of the compressor of the unit.Thus, it should be noted that the topic of creating control systems for compressor units is relevant today. As is known, one of the initial stages of an optimal control system is the construction of a mathematical model based on
APA, Harvard, Vancouver, ISO, and other styles
25

Zhang, Jiawei, Lin Li, Qizhi Zhang, and Yanbin Wu. "Optimization of Load Sharing in Compressor Station Based on Improved Salp Swarm Algorithm." Energies 15, no. 15 (2022): 5720. http://dx.doi.org/10.3390/en15155720.

Full text
Abstract:
In long-distance gas transmission pipelines, there are many booster compressor stations consisting of parallel compressors that provide pressure for the delivery of natural gas. So, it is economically important to optimize the operation of the booster compressor station. The booster compressor station optimization problem is a typical mixed integer nonlinear programming (MINLP) problem, and solving it accurately and stably is a challenge. In this paper, we propose an improved salp swarm algorithm based on good point set, adaptive population division and adaptive inertia weight (GASSA) to solve
APA, Harvard, Vancouver, ISO, and other styles
26

Kurz, R., and R. C. White. "Surge Avoidance in Gas Compression Systems." Journal of Turbomachinery 126, no. 4 (2004): 501–6. http://dx.doi.org/10.1115/1.1777577.

Full text
Abstract:
The phenomenon of compressor surge and its prevention have drawn significant attention in the literature. An important aspect of surge avoidance lies in the design of the compressor station and, in particular, the piping upstream and downstream of the compressor. Most anti-surge systems are perfectly capable of avoiding surge during normal operating conditions. However, unplanned emergency shutdowns present a significant challenge, and surge avoidance in these cases depends to a large degree on the station layout. In this paper, data from a compressor that surged during an emergency shutdown a
APA, Harvard, Vancouver, ISO, and other styles
27

Seyidahmadov, Natig Sabir. "METHODOLOGY OF EXPERIMENTAL INVESTIGATIONS OF VALVE OPERATION." EUREKA: Physics and Engineering 5 (September 17, 2019): 56–63. http://dx.doi.org/10.21303/2461-4262.2019.00991.

Full text
Abstract:
Tightness, as well as the reliability of the valve plate, is a complex property of the effective operation of compressor cylinders of the first stage and, in general, gas-engine reciprocating compressors. The issue of valve plate tightness is a subject of independent study, since technical and economic efficiency depends on their work. In this connection, only some data obtained under operating conditions are presented in this work. As a research result, it is found that, taking into account the identified requirements for the gas lift system, in order to effectively increase the operating hou
APA, Harvard, Vancouver, ISO, and other styles
28

Johnson, Keith D., Craig D. Martin, and Travis G. Davis. "Treatment of Wastewater Effluent from a Natural Gas Compressor Station." Water Science and Technology 40, no. 3 (1999): 51–56. http://dx.doi.org/10.2166/wst.1999.0135.

Full text
Abstract:
Florida Gas Transmission Company (FGTC), an Enron/Sonat affiliate, owns and operates a major interstate natural gas pipeline system that extends from South Texas to South Florida. At various locations along the pipeline are located compressor stations that boost the pressure of the natural gas flowing through the pipelines. As part of their normal operation, these stations generate small amounts of oily effluent as a result of cooling water blow-down, engine/parts wash-down, lube-oil-contaminated wastewater and rainwater from containment areas. In early 1997, economic considerations led FGTC t
APA, Harvard, Vancouver, ISO, and other styles
29

Özcan, Fatih, and Muhsin Kılıç. "Dynamic Modeling of a Compressed Natural Gas Refueling Station and Multi-Objective Optimization via Gray Relational Analysis Method." Applied Sciences 15, no. 9 (2025): 4908. https://doi.org/10.3390/app15094908.

Full text
Abstract:
Compressed natural gas (CNG) refueling stations operate under highly dynamic thermodynamic conditions, requiring accurate modeling and optimization to ensure efficient performance. In this study, a dynamic simulation model of a CNG station was developed using MATLAB-SIMULINK, including detailed subsystems for multi-stage compression, cascade storage, and vehicle tank filling. Real gas effects were incorporated to improve prediction accuracy of the pressure, temperature, and mass flow rate variations during fast filling. The model was validated against experimental data, showing good agreement
APA, Harvard, Vancouver, ISO, and other styles
30

Schreder, Alexander S., Oleg A. Kurasov, Petr V. Burkov, Alexey N. Gavrilin, and Dmitry V. Ermakov. "Negative impact of vibration on process pipelines of a compressor station with electrically driven gas pumping units." Bulletin of the Tomsk Polytechnic University Geo Assets Engineering 335, no. 10 (2024): 167–77. http://dx.doi.org/10.18799/24131830/2024/10/4729.

Full text
Abstract:
Relevance. In gas industry, the amount of equipment that has outlived its intended service life is increasing every year. In accordance with the law “On Industrial Safety of Hazardous Production Facilities,” compressor stations are dangerous objects, the reliable operation of which largely determines the condition of main gas pipelines. Technological pipelines of a compressor station are important objects of this system. They are subject to strict requirements due to the action of static and dynamic loads on them. Reliability of compressor stations is based on the results of a study of the con
APA, Harvard, Vancouver, ISO, and other styles
31

Farukhshina, R. R., S. V. Kitayev, and N. M. Darsaliya. "Improving the Energy Efficiency of a Gas Compression System at a Compressor Station." IOP Conference Series: Earth and Environmental Science 988, no. 3 (2022): 032051. http://dx.doi.org/10.1088/1755-1315/988/3/032051.

Full text
Abstract:
Abstract For natural gas pumping via main gas line gas compressor units are used. During the gas compressor units’ operation, there are natural gas consumption as a fuel and for technological needs. To prevent the escape of gas from the internal cavity of the centrifugal compressor N-370-18-1 into machine room, the design considers a hydraulic seal “oil-gas”. The feature of centrifugal compressor with hydraulic seal “oil-gas” is the discharge of gas from the degassing chamber through a candle into the atmosphere. Rational use of wasted gas make it possible to gain a benefit by saving raw and r
APA, Harvard, Vancouver, ISO, and other styles
32

Faramarzi, Mostafa, Saeed Dinarvand, Mahmood Farzaneh-Gord, and Hossein Tamim. "Analysis of Cylindrical Damper Effects on Turbine Meters Accuracy in a Pulsating CNG Suction Line: An Optimal Design through CFD Simulations." International Journal of Chemical Engineering 2022 (April 18, 2022): 1–13. http://dx.doi.org/10.1155/2022/8745699.

Full text
Abstract:
Turbine meters are used in compressed natural gas (CNG) stations in abundance to measure the volumetric flow rate of the inlet gas. These types of meters are very sensitive to oscillating and pulsating flows. When the station’s reciprocating compressor starts to work, due to the piston and valve performance, pulsating flow will create in the suction line and downstream of turbine meter. This pulsation makes false pulses in the meter and finally makes difference between the measured gas flow from the metering of the gas company and the amount of gas that has been sold at the station. In this st
APA, Harvard, Vancouver, ISO, and other styles
33

Vorontsov, M. A., V. Yu Glazunov, A. S. Grachev, M. S. Mashtalir, S. A. Pospelov, and A. V. Chernyshev. "Analysis of methods for modeling operating modes of compressor equipment that ensures the operation of field low-temperature separation units." Herald of Dagestan State Technical University. Technical Sciences 50, no. 4 (2024): 6–16. http://dx.doi.org/10.21822/2073-6185-2023-50-4-6-16.

Full text
Abstract:
Objective. A booster compressor station (BCS) is one of the key technological facilities necessary to ensure the effective operation of low-temperature separation technology for natural gas in field gas preparation systems for transportation. Ensuring promising operating modes of booster compressor stations with high efficiency is an urgent task. Method. One of the tools for solving this problem is mathematical modeling of the operating modes of centrifugal compressors (hereinafter - CPC), which are part of gas pumping units (GPU). The basis of the mathematical model is the gas dynamic charact
APA, Harvard, Vancouver, ISO, and other styles
34

Arsent'ev, Oleg, Leonid Golovatiukov, Grigory Shitenkov, and Anna Terekhova. "AUTOMATED COMPRESSOR TESTING STATION PNEUMATIC SYSTEMS OF THE DRILLING RIG." Scientific Papers Collection of the Angarsk State Technical University 2023, no. 1 (2023): 170–74. http://dx.doi.org/10.36629/2686-7788-2023-1-170-174.

Full text
Abstract:
The features of the use of pneumatic systems in drilling equipment for oil and gas production are considered. To improve reliability, it is proposed to introduce a test procedure for the main element of the pneumatic system - the compressor. An automated system for testing compressors has been developed, which implements all program modes and allows you to determine the degree of compressor performance
APA, Harvard, Vancouver, ISO, and other styles
35

Berdnik, A. N. "INCREASING THE EFFICIENCY OF FUEL GAS CONSUMPTION OF THE GAS TURBINE ENGINE OF THE COMPRESSOR STATION OF THE MAIN GAS PIPELINE." Spravochnik. Inzhenernyi zhurnal, no. 298 (January 2022): 17–21. http://dx.doi.org/10.14489/hb.2022.01.pp.017-021.

Full text
Abstract:
Various technological schemes for saving fuel gas of a gas turbine engine of a compressor station of a main gas pipeline are presented. Shown is a comparison of technical and economic indicators of a gas turbine engine using three technological schemes associated with the possibility of reducing the consumption of fuel gas at the compressor station of the main gas pipeline.
APA, Harvard, Vancouver, ISO, and other styles
36

Kagiri, Charles, Lijun Zhang, and Xiaohua Xia. "A Hierarchical Optimisation of a Compressed Natural Gas Station for Energy and Fuelling Efficiency under a Demand Response Program." Energies 12, no. 11 (2019): 2165. http://dx.doi.org/10.3390/en12112165.

Full text
Abstract:
Compressed natural gas stations serve customers who have chosen compressed natural gas powered vehicles as an alternative to diesel and petrol based ones, for cost or environmental reasons. The interaction between the compressed natural gas station and electricity grid requires an energy management strategy to minimise a significant component of the operating costs of the station where demand response programs exist. Such a strategy when enhanced through integration with a control strategy for optimising gas delivery can raise the appeal of the compressed natural gas, which is associated with
APA, Harvard, Vancouver, ISO, and other styles
37

Kamala Aliyeva, Kamala Aliyeva, and Elsevar Allahverdiyev Elsevar Allahverdiyev. "IMPROVEMENT OF WORKING PERFORMANCE OF THE GAS COMPRESSOR STATION." PAHTEI-Procedings of Azerbaijan High Technical Educational Institutions 07, no. 03 (2021): 18–24. http://dx.doi.org/10.36962/0703202118.

Full text
Abstract:
The working performance of compressor unit for compressing of gas to required pressure for injection of gas to underground reservoir and for transportation of it is considered. Performance data of compressor station for 2018 and 2019 analyzed. Dependencies of power consumption, specific consumption of gas which uses as fuel for compressor is designed. Changes in noted above parameters during given two years are found based on detail analysis. The expediency of processing the signals of the sensors connected to the monitoring and control system of the compressor station, using fuzzy logic algor
APA, Harvard, Vancouver, ISO, and other styles
38

Harasymiv, V. M., O. V. Moiseenko, and T. G. Harasymiv. "Application and algorithmic software of the control system of the technical state parameters of the two-stage centrifugal compressor." METHODS AND DEVICES OF QUALITY CONTROL, no. 1(44) (June 28, 2020): 110–18. http://dx.doi.org/10.31471/1993-9981-2020-1(44)-110-118.

Full text
Abstract:
Efficiency of the technical state of the compressor station basic components depends on the timely prediction of the appearance of damages. It is defined by the estimation of the technical state of the basic components during the compression process. It is known that the two-stage centrifugal compressors are commonly used in the Ukrainian compressor stations. So, application software and algorithm for the two-stage centrifugal compressor have been developed, what allows to define its technical state parameters, taking into account the construction features of the compressor volute. The algorit
APA, Harvard, Vancouver, ISO, and other styles
39

Mykhail, Kologrivov, and Buzovskyi Vitalii. "Development of a model of the optimal temperature mode of the main gas pipeline operation." Eastern-European Journal of Enterprise Technologies 5, no. 8 (113) (2021): 30–37. https://doi.org/10.15587/1729-4061.2021.242440.

Full text
Abstract:
The influence of the ambient air temperature on changes in the parameters and thermophysical characteristics of the gas pumped through the underground pipeline was investigated. This was done because there are no scientifically sound recommendations for the optimal gas temperature after coolers at the compressor station. The presence of the site of inversion of heat exchange between gas and soil – a change in the direction of heat exchange along the length of the gas pipeline was revealed. It was proved that the air temperature above the soil surface should be substituted into the formul
APA, Harvard, Vancouver, ISO, and other styles
40

Ohanian, S., and R. Kurz. "Series of Parallel Arrangement in a Two-Unit Compressor Station." Journal of Engineering for Gas Turbines and Power 124, no. 4 (2002): 936–41. http://dx.doi.org/10.1115/1.1478074.

Full text
Abstract:
This paper discusses how to determine the arrangement of compressors in a two-unit gas pipeline station where there is no standby unit. The compressors are driven by variable speed drivers such as gas turbines or variable frequency electric motors. Both series and parallel arrangements are analyzed in a transient simulation mode to determine which operation mode is more advantageous. Among the assumptions in this paper are the performance characteristics of the compressor. It will be outlined how these performance characteristics influence the conclusions.
APA, Harvard, Vancouver, ISO, and other styles
41

Botros, K. K., P. J. Campbell, and D. B. Mah. "Dynamic Simulation of Compressor Station Operation Including Centrifugal Compressor and Gas Turbine." Journal of Engineering for Gas Turbines and Power 113, no. 2 (1991): 300–311. http://dx.doi.org/10.1115/1.2906563.

Full text
Abstract:
Dynamic simulation of the operation of a compressor station requires mathematical modeling of the dynamic behavior of the compressor unit and various piping elements. Such models consist of large systems of nonlinear partial differential equations describing the pipe flow together with nonlinear algebraic equations describing the quasi-steady flow through various valves, constrictions, and compressors. In addition, the models also include mathematical descriptions of the control system, which consists of mixed algebraic and ordinary differential (mad) equations with some inequalities represent
APA, Harvard, Vancouver, ISO, and other styles
42

Grudz, Volodymyr, Yaroslav Grudz, Myroslav Iakymiv, Mykola Iakymiv, and Pavlo Iagoda. "Forecasting rational working modes of long-operated gas-transport systems under conditions of their incomplete loading." Eastern-European Journal of Enterprise Technologies 4, no. 8(112) (2021): 6–15. http://dx.doi.org/10.15587/1729-4061.2021.239147.

Full text
Abstract:
Prolonged operation of the gas-transport system in conditions of partial loading involves frequent changes in the volume of gas transportation, which necessitates prompt forecasting of system operation. When forecasting the modes of operation of the gas transport system, the main criterion of optimality implies the maximum volume of gas pumping. After all, in this case, the largest profit of the gas-transport company is achieved under the condition of full provision of consumers with energy. In conditions of incomplete loading of the gas-transport system caused by a shortage of gas supply, opt
APA, Harvard, Vancouver, ISO, and other styles
43

Volodymyr, Grudz, Grudz Yaroslav, Iakymiv Myroslav, Iakymiv Mykola, and Iagoda Pavlo. "Forecasting rational working modes of long-operated gas-transport systems under conditions of their incomplete loading." Eastern-European Journal of Enterprise Technologies 4, no. 8 (112) (2021): 6–15. https://doi.org/10.15587/1729-4061.2021.239147.

Full text
Abstract:
Prolonged operation of the gas-transport system in conditions of partial loading involves frequent changes in the volume of gas transportation, which necessitates prompt forecasting of system operation. When forecasting the modes of operation of the gas transport system, the main criterion of optimality implies the maximum volume of gas pumping. After all, in this case, the largest profit of the gas-transport company is achieved under the condition of full provision of consumers with energy. In conditions of incomplete loading of the gas-transport system caused by a shortage of gas supply, opt
APA, Harvard, Vancouver, ISO, and other styles
44

Makarov, Nikolai, and Vladimir Makarov. "Local diffusion airfoil control as an effective way of increasing the adaptability of gas air cooler fan unit." Izvestiya vysshikh uchebnykh zavedenii. Gornyi zhurnal 1 (February 15, 2022): 72–83. http://dx.doi.org/10.21440/0536-1028-2022-1-72-83.

Full text
Abstract:
Problem statement. Industrial safety and compressed gas cooling efficiency at compressor stations of the main gas pipeline is an essential task that gives urgency to the issue of mathematical modeling of energy conversion control in the impellers of gas air cooler (GAC) fan units. GAC fan units are high-speed and adaptable. So, they can make the Russian oil and gas complex highly competitive globally. Research objective is to develop a method of controlling the diffusion airfoil of the impeller blade profiles, which is the main reason for GAC fan units’ low adaptability. Methods of research. T
APA, Harvard, Vancouver, ISO, and other styles
45

Asyari, Rena Amalika. "PEMODELAN PENENTUAN LOKASI STASIUN KOMPRESOR UNTUK PIPA TRANSMISI GAS DARI SUMATERA SELATAN – JAWA BARAT." Jurnal E-Komtek (Elektro-Komputer-Teknik) 2, no. 1 (2019): 43–53. http://dx.doi.org/10.37339/e-komtek.v2i1.93.

Full text
Abstract:
In the gas transmission pipe system definitely will be affected by several good factors was external and internal. The factor external like the influence of the outside environment also topography this territory. The internal factor like the friction, head loss and other. The pressure that was given in the point of the beginning the station, will experience the decline in the pressure together with the transmission of this gas. If this situation was allowed then gas will not arrive at his aim. So was needed by a functioning motive power increased the pressure, until gas arrived at his destinat
APA, Harvard, Vancouver, ISO, and other styles
46

Kolotilov, Yu V., S. V. Kitaev, N. M. Darsalia, and O. V. Smorodova. "SYSTEM ANALYSIS OF EQUIPMENT OF COMPRESSOR STATIONS ON MAIN GAS PIPELINES TO ESTABLISH THE PRIORITIES OF EFFICIENT USE OF ENERGY RESOURCES." Oil and Gas Studies, no. 3 (July 1, 2017): 106–11. http://dx.doi.org/10.31660/0445-0108-2017-3-106-111.

Full text
Abstract:
It is shown that it is possible to significantly improve the energy efficiency of compressor stations on gas pipelines in underloading conditions. Significant energy savings can be obtained through the use of optimization calculations of the design characteristics of the real gas pumping units and to implement such an urgent task it is necessary to develop a variety of mathematical models of system analysis with the possibility of their implementation in the design optimization of compressor station complexes.
APA, Harvard, Vancouver, ISO, and other styles
47

Odilov, Nurmukhammad. "SAFETY METHODS AT GAS FILLING STATIONS FOR CARS." Journal of Academic Research and Trends in Educational Sciences 1, no. 1 (2021): 27–36. https://doi.org/10.5281/zenodo.5732362.

Full text
Abstract:
This article analyzes the advantages and disadvantages of compressed natural gas used as a fuel in cars, as well as safety rules at gas filling compressor stations. The main causes of the explosion of gas cylinders in cars are described, and recommendations for improving measures to prevent them are developed.
APA, Harvard, Vancouver, ISO, and other styles
48

Wadhah H. Al Doori, Anmmar Mahmoud Ahmed, and Ahmed Hasan Ahmed. "Modern Thermodynamic Analysis by the Energic-Exergic Method of Gas Turbine Power Plants 55 MW in Taza-Iraq." CFD Letters 14, no. 10 (2022): 112–19. http://dx.doi.org/10.37934/cfdl.14.10.112119.

Full text
Abstract:
Abstract Because of the increasing demand for energy in the recent period, it has become necessary to intensify the study in the field of evaluating the performance of the gas station under the first and second laws efficiency. The energy and exergy losses of gas stations are represented by the compressor, combustion chamber, and turbine. Therefore, this work aims to analyze the energy and exergy of a 55 MW Taza gas power station. The investigation demonstrated that the most significant misfortunes of the exergy happened in the combustion chamber, where was 66.5MW the most minimal misfortunes
APA, Harvard, Vancouver, ISO, and other styles
49

Kologrivov, Mykhail, and Vitalii Buzovskyi. "Development of a model of the optimal temperature mode of the main gas pipeline operation." Eastern-European Journal of Enterprise Technologies 5, no. 8 (113) (2021): 30–37. http://dx.doi.org/10.15587/1729-4061.2021.242440.

Full text
Abstract:
The influence of the ambient air temperature on changes in the parameters and thermophysical characteristics of the gas pumped through the underground pipeline was investigated. This was done because there are no scientifically sound recommendations for the optimal gas temperature after coolers at the compressor station. The presence of the site of inversion of heat exchange between gas and soil – a change in the direction of heat exchange along the length of the gas pipeline was revealed. It was proved that the air temperature above the soil surface should be substituted into the formula for
APA, Harvard, Vancouver, ISO, and other styles
50

Gorbijchuk, M. I., O. T. Bila, B. V. Pashkovskyi, and N. T. Lazoriv. "ALGORITHMIC AND SOFTWARE OF THE COMPUTER SYSTEM FOR THE SELECTION OF OPTIMAL QUANTITY OF NATURAL GAS OPERATING PARALLEL WORKERS." METHODS AND DEVICES OF QUALITY CONTROL, no. 1(42) (June 27, 2019): 47–55. http://dx.doi.org/10.31471/1993-9981-2019-1(42)-47-55.

Full text
Abstract:
In connection with reduction of volumes of transporting of gas through the gas-transport system of Ukraine the issue of the day is the rational loading of the compressor stations taking into account the technical state of gascompressor units. The mathematical model was developed in the article on principles of fuzzy logic, that gave an opportunity to define the technical state of gascompressor units that are working in parallel taking into account such parameters as the productivity of supercharger, expense of fuel gas, pressure and temperature on an entrance, pressure and temperature on the e
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!