To see the other types of publications on this topic, follow the link: Generator voltage regulation.

Dissertations / Theses on the topic 'Generator voltage regulation'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 dissertations / theses for your research on the topic 'Generator voltage regulation.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

Aintablian, Hrair. "External characteristics and voltage regulation of a 3-phase induction generator under load." Ohio : Ohio University, 1989. http://www.ohiolink.edu/etd/view.cgi?ohiou1182275061.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Elkhomri, Othman. "DSP IMPLEMENTATION OF DC VOLTAGE REGULATION USING ADAPTIVE CONTROL FOR 200 KW 62000 RPM INDUCTION GENERAT." Master's thesis, University of Central Florida, 2006. http://digital.library.ucf.edu/cdm/ref/collection/ETD/id/2926.

Full text
Abstract:
The thesis discusses the development of closed loop system to control the DC voltage for 200 kW induction generator rated at a speed of 62000 RPM under different load conditions. The voltage regulation has been implemented using PI controller. A gain scheduling control algorithm has been developed to select the appropriate controller gains with respect to the generator load. Further, a relationship between the generator loads and the controller gains has been established. This relationship has been modeled using adaptive control technique to vary the gains automatically at any load condition.
APA, Harvard, Vancouver, ISO, and other styles
3

Tischer, Celso Becker. "Desenvolvimento de uma topologia híbrida a três fios para regulação de tensão aplicada em microcentrais hidrelétricas." Universidade Federal de Santa Maria, 2013. http://repositorio.ufsm.br/handle/1/8522.

Full text
Abstract:
Conselho Nacional de Desenvolvimento Científico e Tecnológico<br>This dissertation presents the study of a three-wire hibrid topology for voltage regulation for micro-hydroelectric generators that use self-excited induction in isolated operation. Initially, a literature review is presented in order to identify the main voltage regulation topologies applied to self-excited induction generators in the literature. From this review, a hybrid topology is proposed, which aims to regulate the voltage supplied by the generator to the isolated system. Thus, the mathematical modeling of the system is pr
APA, Harvard, Vancouver, ISO, and other styles
4

Trapp, Jordan Gustavo. "Gerador de indução isolado com tensão e freqüência reguladas por conversor matricial esparso." Universidade Federal de Santa Maria, 2008. http://repositorio.ufsm.br/handle/1/8454.

Full text
Abstract:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior<br>The induction generator has characteristics making it interesting for alternative sources of energy, such as low cost, ruggedness, low maintenance, high availability and good dynamic behavior. So, it is very much applied in alternative energy systems, where low cost, low maintenance and easy availability are essential characteristics. Although this generator is very attractive, its operation presents problems related to a poor voltage regulation, load dependent variable frequency, and the need of large size self-excitation capacito
APA, Harvard, Vancouver, ISO, and other styles
5

Scherer, Lucas Giuliani. "Topologia híbrida e métodos de controle aplicados à regulação de tensão de geradores de indução auto-excitados." Universidade Federal de Santa Maria, 2016. http://repositorio.ufsm.br/handle/1/3698.

Full text
Abstract:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior<br>This doctoral thesis deals with the study, analysis and development of a new hybrid topology for voltage regulation of stand-alone microgeneration systems employing self-excited induction generators. The hybrid topology proposed considers a three-phase four-wire system and employs a distribution static synchronous compensator (DSTATCOM) in combination with banks of switchable capacitors (BCC) to perform the regulation of the terminal voltages of the induction generator. As a result of using the proposed topology, it is expected the
APA, Harvard, Vancouver, ISO, and other styles
6

Nye, Jonathan Mark. "Increasing distributed generation penetration when limited by voltage regulation." Thesis, Stellenbosch : Stellenbosch University, 2014. http://hdl.handle.net/10019.1/86605.

Full text
Abstract:
Thesis (MEng)--Stellenbosch University, 2014.<br>ENGLISH ABSTRACT: This work investigated the influence of photo-voltaic generators on the voltage control of distribution feeders and the methods that can be used to increase the maximum penetration levels of these feeders. Initially, a brief overview of the reasons why it is necessary to increase the generation penetration levels on distribution feeders was provided. A review of various issues associated with connecting generation to the distribution network; methods and technologies that can be used to increase penetration levels; and ways to
APA, Harvard, Vancouver, ISO, and other styles
7

Guimaraes, Geraldo C. "Computer methods for transient stability analysis of isolated power generation systems with special reference to prime mover and induction motor modelling." Thesis, University of Aberdeen, 1990. http://digitool.abdn.ac.uk/R?func=search-advanced-go&find_code1=WSN&request1=AAIU028173.

Full text
Abstract:
This thesis aims to establish computer methods for the transient stability analysis of electric power systems which operate isolated from the large interconnected system. A typical isolated system is characterized by a compact network in which the size of the load is relatively large when compared to the total, installed generation capacity. The stability problems are thus more severe for this system than for the grid-type system. This results in the need for more accurate representations for the system components in the computer studies. This work considers particularly the prime mover and th
APA, Harvard, Vancouver, ISO, and other styles
8

WANG, YAWEI. "High Performance Synchronous Reluctance Machines: Design and Applications." Doctoral thesis, Università degli studi di Padova, 2018. http://hdl.handle.net/11577/3425753.

Full text
Abstract:
As one of the oldest machine topologies, the concept of synchronous reluctance (REL) machine can be traced back as early as 1900s. In the last 20 years, particularly, the REL machines have attracted more and more attention in both academic and industrial fields. Without permanent magnets and rotor bars, the rotor construction of the REL machine is more robust than either permanent magnet (PM) machines or induction machines (IMs). In addition, it achieves the merits of low cost, low maintenance, and high reliability. All these features reveal the REL machine to be an attractive alternative to t
APA, Harvard, Vancouver, ISO, and other styles
9

BARTESELLI, EDOARDO. "Accurate Voltage Reference Generator for Audio Interface in 65/55nm CMOS Technology." Doctoral thesis, Università degli Studi di Milano-Bicocca, 2022. http://hdl.handle.net/10281/364988.

Full text
Abstract:
Negli ultimi anni i dispositivi mobili sono molto complessi e ricchi di funzionalità che consumano molta energia. Per questo motivo, l'industria elettronica sta spingendo verso la riduzione del consumo di energia e corrente nei dispositivi elettronici per aumentare la durata della batteria. Tutto va fatto mantenendo le stesse prestazioni o migliorandole. Questa tesi presenta un accurato generatore di riferimento di tensione per interfaccia audio in tecnologia CMOS a 65/55nm e particolare attenzione è stata posta al consumo di corrente. Il riferimento è costituito da un riferimento di tensione
APA, Harvard, Vancouver, ISO, and other styles
10

Ivanic, Boris. "AVR for a synchronous generator with a six-phase PM alternator and rotating excitation system." Thesis, Uppsala universitet, Elektricitetslära, 2013. http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-201997.

Full text
Abstract:
Automatic voltage regulation is necessary for all power producing synchronous generators to ensure that the produced power have a constant and stable voltage level and to sustain grid stability. The aim of this thesis is to design and build an automatic voltage regulator for a synchronous generator. A six-phase permanent magnet alternator will be used to excite the rotor with solid-state relay controlled rotating bridge rectifier. The field current is regulated by a closed loop control system that is based on a programmable logic controller, PLC. Programing of the PLC is executed in the develo
APA, Harvard, Vancouver, ISO, and other styles
11

Tibebu, Eyuel. "An automatic voltage regulating system with Bluetooth communicating devices for brushless excitation of a synchronous generator." Thesis, Uppsala universitet, Elektricitetslära, 2013. http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-202587.

Full text
Abstract:
This thesis has been performed in order to earn a master's degree in electrical engineering. The task was to implement an automatic voltage regulator, AVR, to control the terminal voltage of the synchronous generator Svante at the Division of Electricity at Uppsala University. The AVR uses Bluetooth technology to transfer a control signal produced by a programmable logical controller, PLC, to phase- mounted SSRs that decides what proportion of the AC from a six-phase brushless exciter that is to be used for the magnetization of the rotor. Test runs of the AVR were preformed with a regulator op
APA, Harvard, Vancouver, ISO, and other styles
12

Padilha, Lucas Nery. "Análise comparativa de estratégias para regulação de tensão em sistemas de distribuição de energia elétrica na presença de geradores distribuídos." Universidade de São Paulo, 2010. http://www.teses.usp.br/teses/disponiveis/18/18154/tde-10082010-141601/.

Full text
Abstract:
Para que a instalação de geração distribuída possa de fato beneficiar a operação das redes de distribuição e de subtransmissão de energia elétrica, seus impactos técnicos devem ser cuidadosamente estudados, sobretudo em redes de distribuição, as quais foram inicialmente planejadas para operar com fluxo de potência unidirecional. Dentre esses impactos, a influência da geração distribuída na regulação da tensão é um aspecto de suma importância, pois está diretamente relacionada à qualidade do fornecimento da energia elétrica aos consumidores. Neste contexto, é importante conhecer e dispor de mei
APA, Harvard, Vancouver, ISO, and other styles
13

OLIVEIRA, Tiago Elias Castelo de. "The Concept of Dynamic Hosting Capacity of Distributed Renewable Generation Considering Voltage Regulation and Harmonic Distortion." reponame:Repositório Institucional da UNIFEI, 2018. http://repositorio.unifei.edu.br/xmlui/handle/123456789/1817.

Full text
Abstract:
Submitted by repositorio repositorio (repositorio@unifei.edu.br) on 2018-11-27T18:05:11Z No. of bitstreams: 1 tese_2018033.pdf: 33566735 bytes, checksum: 64079a275e2a232b703a2e509e9a8d04 (MD5)<br>Made available in DSpace on 2018-11-27T18:05:11Z (GMT). No. of bitstreams: 1 tese_2018033.pdf: 33566735 bytes, checksum: 64079a275e2a232b703a2e509e9a8d04 (MD5) Previous issue date: 2018-09<br>This thesis introduces a brief analysis on hosting capacity and related concepts as applied to distribution network systems. Furthermore, it addresses the applicability of hosting capacity study methodologies t
APA, Harvard, Vancouver, ISO, and other styles
14

Zhao, Huiying. "Regulation and Control of AC Microgrid Systems with Renewable Generation and Battery Energy Storage System." Case Western Reserve University School of Graduate Studies / OhioLINK, 2018. http://rave.ohiolink.edu/etdc/view?acc_num=case1536342769000338.

Full text
APA, Harvard, Vancouver, ISO, and other styles
15

Ahmed, Mohamed Hassan Abouelella. "Power Architectures and Design for Next Generation Microprocessors." Diss., Virginia Tech, 2019. http://hdl.handle.net/10919/103175.

Full text
Abstract:
With the rapid increase of cloud computing and the high demand for digital content, it is estimated that the power consumption of the IT industry will reach 10 % of the total electric power in the USA by 2020. Multi-core processors (CPUs) and graphics processing units (GPUs) are the key elements in fulfilling all of the digital content requirements, but come with a price of more power-hungry processors, driving the power per server rack to 20 KW levels. The need for more efficient power management solutions on the architecture level, down to the converter level, is inevitable. Recently, data c
APA, Harvard, Vancouver, ISO, and other styles
16

Ghosh, Shibani. "A Real-time Management of Distribution Voltage Fluctuations due to High Solar Photovoltaic (PV) Penetrations." Diss., Virginia Tech, 2017. http://hdl.handle.net/10919/74424.

Full text
Abstract:
Due to the rapid growth of grid-tied solar photovoltaic (PV) systems in the generation mix, the distribution grid will face complex operational challenges. High PV penetration can create overvoltages and voltage fluctuations in the network, which are major concerns for the grid operator. Traditional voltage control devices like switched capacitor banks or line voltage regulators can alleviate slow-moving fluctuations, but these devices need to operate more frequently than usual when PV generation fluctuates due to fast cloud movements. Such frequent operations will impact the life expectancy o
APA, Harvard, Vancouver, ISO, and other styles
17

Godoy, Lívia Lisandro Judice. "Utilização de unidades de microgeração fotovoltaica para regulação centralizada de tensão." reponame:Biblioteca Digital de Teses e Dissertações da UFRGS, 2017. http://hdl.handle.net/10183/173132.

Full text
Abstract:
A Geração Distribuída no Brasil tem crescido ao longo dos anos, especialmente na fonte fotovoltaica e na categoria que a ANEEL denomina microgeração distribuída, que são centrais geradoras de energia elétrica com potência instalada menor ou igual a 75 kW e conectada na rede de distribuição por meio de instalações de unidades consumidoras. Apesar dos problemas tradicionais que podem ocorrer com a inserção em larga escala, como maiores perdas e desvios de tensão, as placas fotovoltaicas, conectadas à rede de distribuição por meio de um inversor, trazem a possibilidade de controlar a tensão no po
APA, Harvard, Vancouver, ISO, and other styles
18

Ami, Sumit Mazumder. "Power quality improvements in low voltage distribution networks containing distributed energy resources." Thesis, Queensland University of Technology, 2015. https://eprints.qut.edu.au/81410/1/Sumit%20Mazumder_Ami_Thesis.pdf.

Full text
Abstract:
In this thesis various schemes using custom power devices for power quality improvement in low voltage distribution network are studied. Customer operated distributed generators makes a typical network non-radial and affect the power quality. A scheme considering different algorithm of DSTATCOM is proposed for power circulation and islanded operation of the system. To compensate reactive power overflow and facilitate unity power factor, a UPQC is introduced. Stochastic analysis is carried out for different scenarios to get a comprehensive idea about a real life distribution network. Combined o
APA, Harvard, Vancouver, ISO, and other styles
19

Ziari, Iman. "Planning of distribution networks for medium voltage and low voltage." Thesis, Queensland University of Technology, 2011. https://eprints.qut.edu.au/46684/1/Iman_Ziari_Thesis.pdf.

Full text
Abstract:
Determination of the placement and rating of transformers and feeders are the main objective of the basic distribution network planning. The bus voltage and the feeder current are two constraints which should be maintained within their standard range. The distribution network planning is hardened when the planning area is located far from the sources of power generation and the infrastructure. This is mainly as a consequence of the voltage drop, line loss and system reliability. Long distance to supply loads causes a significant amount of voltage drop across the distribution lines. Capacitors
APA, Harvard, Vancouver, ISO, and other styles
20

Pramono, Hadi Sasongko. "Etude et réalisation de régulateurs adaptatifs numériques de tension et de vitesse d'un groupe turbo-alternateur." Grenoble INPG, 1988. http://www.theses.fr/1988INPG0052.

Full text
Abstract:
Cette thèse décrit l'étude et la réalisation d'un régulateur numérique de groupe turbo alternateur dont les paramètres varient en fonction du point de fonctionnement de la machine. D'abord, une étude comparative d'application de la commande adaptative aux groupes de production est présentée. Les méthodes de commande adaptative comportant le schéma, la stratégie, le type et le nombre de variables sont analysées dans la suite de façon à trouver la plus convenable. Ensuite, est présentée l'étude théorique de la conception de régulateurs adaptatifs modal et optimal. Les performances des régulateur
APA, Harvard, Vancouver, ISO, and other styles
21

Sagha, Hossein. "Development of innovative robust stability enhancement algorithms for distribution systems containing distributed generators." Thesis, Queensland University of Technology, 2015. https://eprints.qut.edu.au/91052/1/Hossein_Sagha_Thesis.pdf.

Full text
Abstract:
This project was a step forward in improving the voltage profile of traditional low voltage distribution networks with high photovoltaic generation or high peak demand. As a practical and economical solution, the developed methods use a Dynamic Voltage Restorer or DVR, which is a series voltage compensator, for continuous and communication-less power quality enhancement. The placement of DVR in the network is optimised in order to minimise its power rating and cost. In addition, new approaches were developed for grid synchronisation and control of DVR which are integrated with the voltage qual
APA, Harvard, Vancouver, ISO, and other styles
22

Silva, Daniel Leandro da. "Análise do uso de baterias para o problema do impacto da conexão de geração fotovoltaica à rede de distribuição." reponame:Repositório Institucional da UFABC, 2017.

Find full text
Abstract:
Orientadora: Profa. Dra. Ahda Pionkoski Grilo Pavani<br>Dissertação (mestrado) - Universidade Federal do ABC, Programa de Pós-Graduação em Engenharia Elétrica, Santo André, 2017.<br>O uso da energia solar fotovoltaica tem aumentado significativamente nos últimos anos. Atualmente, uma das formas mais empregadas para o aproveitamento desta fonte de energia é a instalação de placas fotovoltaicas em telhados de instalações residenciais. No Brasil, especificamente, este tipo de instalação vem crescendo desde a implementação do sistema de compensação de créditos, em que os consumidores podem injetar
APA, Harvard, Vancouver, ISO, and other styles
23

Katewa, Luis. "Pre-study and system design of a mobile platform simulator system." Thesis, KTH, Hälsoinformatik och logistik, 2018. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-288928.

Full text
Abstract:
There are many ways to produce energy, using e.g. gas or hydro turbines. To guarantee a stable power output, it is important to consider components that could control and adjust the output power automatically. The intention of this thesis work is to carry out a pre-study and system design of a mobileplatform simulator system that could be used by companies like Siemens and help them to reduce their OPEX (Operational expenditure) and easily evaluate their AVR (AutomaticVoltage Regulator) solutions and test improvements. In this document, Siemens has decided to call the simulator system, MPSS (M
APA, Harvard, Vancouver, ISO, and other styles
24

Tonhá, Henrique Mesquita. "Análise da geração distribuída sob a perspectiva de maximização de potência injetada em sistemas de distribuição." Universidade Federal de Goiás, 2017. http://repositorio.bc.ufg.br/tede/handle/tede/7401.

Full text
Abstract:
Submitted by Erika Demachki (erikademachki@gmail.com) on 2017-06-01T22:22:40Z No. of bitstreams: 2 Dissertação - Henrique Mesquita Tonhá - 2017.pdf: 3159304 bytes, checksum: 5bac33b411dcef9b02cd77d8fda8d1a8 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)<br>Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2017-06-02T11:12:05Z (GMT) No. of bitstreams: 2 Dissertação - Henrique Mesquita Tonhá - 2017.pdf: 3159304 bytes, checksum: 5bac33b411dcef9b02cd77d8fda8d1a8 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)<br>M
APA, Harvard, Vancouver, ISO, and other styles
25

Alves, Guilherme Henrique. "Uma proposta de regulador automático de tensão microcontrolado para geradores síncronos isolados." Universidade Federal de Uberlândia, 2016. https://repositorio.ufu.br/handle/123456789/17931.

Full text
Abstract:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior<br>Os sistemas de controle de excitação em máquinas síncronas devem detectar com bastante rapidez as mudanças causadas pela entrada de carga no gerador isolado e atuar no sistema de excitação de forma rápida e eficiente, para manter a tensão terminal em níveis desejados. Ao contrário de outros trabalhos realizados nesta área com circuitos eletrônicos analógicos, em muitos casos, este controlador pode ser construído utilizando tecnologia microcontrolada por possuir alto nível de eficiência no controle, circuito com flexibilidade para i
APA, Harvard, Vancouver, ISO, and other styles
26

Sousa, Neto Cecilio Martins de. "Estabilizador de sistema de pot?ncia para m?quinas s?ncronas de polos salientes utilizando a transformada Wavelet." Universidade Federal do Rio Grande do Norte, 2013. http://repositorio.ufrn.br:8080/jspui/handle/123456789/15474.

Full text
Abstract:
Made available in DSpace on 2014-12-17T14:56:13Z (GMT). No. of bitstreams: 1 CecilioMSN_DISSERT.pdf: 1132732 bytes, checksum: 95ce32ef2cdf325116d25b76e2b1858a (MD5) Previous issue date: 2013-07-05<br>Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico<br>The power system stabilizers are used to suppress low-frequency electromechanical oscillations and improve the synchronous generator stability limits. This master thesis proposes a wavelet-based power system stabilizer, composed of a new methodology for extraction and compensation of electromechanical oscillations in electrical pow
APA, Harvard, Vancouver, ISO, and other styles
27

CARVALHO, Rodrigo Mendonça de. "Reguladores de tensão e geração distribuída em uma implementação de fluxo de potência a três e a quatro fios." Universidade Federal de Goiás, 2012. http://repositorio.bc.ufg.br/tede/handle/tde/974.

Full text
Abstract:
Made available in DSpace on 2014-07-29T15:08:18Z (GMT). No. of bitstreams: 1 DISSERTACAO_MESTRADO_Rodrigo M de Carvalho_2012.pdf: 3438844 bytes, checksum: 3b54078140704053b5706662ad841ff3 (MD5) Previous issue date: 2012-04-20<br>As a distribution network grows, the need for voltage control and regulator devices increases, as well as the need for supplying the demands, which assists in monitoring and correction of their magnitudes. Thus, the use of voltage regulators and, more recently, distributed generation applications contribute to the improvement of the process of electric power distribu
APA, Harvard, Vancouver, ISO, and other styles
28

Carolino, Su?lio Fernandes. "Regulador autom?tico de tens?o robusto utilizando t?cnicas de controle adaptativo." Universidade Federal do Rio Grande do Norte, 2013. http://repositorio.ufrn.br:8080/jspui/handle/123456789/15466.

Full text
Abstract:
Made available in DSpace on 2014-12-17T14:56:12Z (GMT). No. of bitstreams: 1 SuelioFC_DISSERT.pdf: 1266723 bytes, checksum: 8001a23164a7a48663a60001950fc3e0 (MD5) Previous issue date: 2013-02-01<br>Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico<br>The stability of synchronous generators connected to power grid has been the object of study and research for years. The interest in this matter is justified by the fact that much of the electricity produced worldwide is obtained with the use of synchronous generators. In this respect, studies have been proposed using conventional an
APA, Harvard, Vancouver, ISO, and other styles
29

Kincl, Zdeněk. "Multifunkční display pro pozemní zdroj." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2009. http://www.nusl.cz/ntk/nusl-217990.

Full text
Abstract:
The aim of this thesis was to design a concept and circuit for multifunction display. This unit is used in ground power supply for preflighting preparation of army helicopters. Multifunction display measures voltages and currents of AC and DC generators, teperatures of cooling air and fuel quantity. Display indicates a operational and fault states of ground power supply. The main element of multifunction display is 32-bit microprocessor from the manufacturer NXP, family ARM7. All information are displaying on graphic vacuum fluorescent display GU256x128.
APA, Harvard, Vancouver, ISO, and other styles
30

Peres, Larissa Marques. "Estudos de desempenho dinâmico de geradores síncronos de produtores independentes em sistemas de geração distribuída via ATPDraw." Universidade Federal de Uberlândia, 2013. https://repositorio.ufu.br/handle/123456789/14545.

Full text
Abstract:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior<br>This work aims to analyze the dynamic performance of a synchronous generator and its controls in a distributed generation system, as well as evaluate the impacts of its operation when connected to the distribution grid, using for this task the ATPDraw interface/tool of software ATP. Within this context, it is firstly necessary to obtain suitable models to represent the synchronous machine control systems (voltage regulator, speed governor and stabilizer system) in ATPDraw. Furthermore, for stability analysis, it is developed a math
APA, Harvard, Vancouver, ISO, and other styles
31

Hrtáň, Michal. "Pomocné vinutí pro napájení napěťového regulátoru synchronního generátoru." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2014. http://www.nusl.cz/ntk/nusl-220567.

Full text
Abstract:
The theme of this thesis is the design and verification of the auxiliary winding to supply the voltage regulator of the synchronous generator. The synchronous generator for which the auxiliary winding proposed is three-phase, low voltage with double layer random wound stator winding. The generator excitation is brushless with auxiliary rotating exciter. The auxiliary winding is designed for placement in the stator teeth, along with the main winding. The sizing of the auxiliary winding is derived from the power requirements the voltage regulator. Draft winding is validated analytical calculatio
APA, Harvard, Vancouver, ISO, and other styles
32

Sattouf, Mousa. "Systém snímání dat a ovládání vodní elektrárny prostřednictvím internetové techniky." Doctoral thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2015. http://www.nusl.cz/ntk/nusl-233685.

Full text
Abstract:
Vodní energie se nyní stala nejlepším zdrojem elektrické energie na zemi. Vyrábí se pomocí energie poskytované pohybem nebo pádem vody. Historie dokazuje, že náklady na tuto elektrickou energii zůstávají konstantní v průběhu celého roku. Vzhledem k mnoha výhodám, většina zemí nyní využívá vodní energie jako hlavní zdroj pro výrobu elektrické energie.Nejdůležitější výhodou je, že vodní energie je zelená energie, což znamená, že žádné vzdušné nebo vodní znečišťující látky nejsou vyráběny, také žádné skleníkové plyny jako oxid uhličitý nejsou vyráběny, což činí tento zdroj energie šetrný k životn
APA, Harvard, Vancouver, ISO, and other styles
33

Chang, Tze Hwa, and 張志華. "Implement of Voltage Regulation of Synchronous Generator Using." Thesis, 1995. http://ndltd.ncl.edu.tw/handle/18908198559335627209.

Full text
APA, Harvard, Vancouver, ISO, and other styles
34

MENG-TA, YOU, and 游孟達. "Development of Voltage Regulation Controller for Vehicle Synchronous Generator." Thesis, 2018. http://ndltd.ncl.edu.tw/handle/56mt6g.

Full text
Abstract:
碩士<br>明新科技大學<br>電機工程系碩士班<br>106<br>Abstract This paper presents an improved power supply voltage regulator system for vehicles. The system includes a permanent magnet synchronous generator, a three-phase full-bridge power transistor switch (MOSFET), an engine ignition system with 42V or (12V) 18650 Lithium battery ,and a rotor magnetic field-oriented vector controller (FOC). The composition of the voltage loop controller. converting control variables from static coordinate to synchronous rotation coordinate. designed with of the PI Controller is in the synchronous rotation coordinate. The 1865
APA, Harvard, Vancouver, ISO, and other styles
35

Huang, Wei-Kang, and 黃維綱. "A Dynamic Voltage Restorer for the Voltage Regulation of a Grid-tied Squirrel-cage Induction Generator." Thesis, 2011. http://ndltd.ncl.edu.tw/handle/08995278877551962429.

Full text
Abstract:
碩士<br>國立臺灣大學<br>電機工程學研究所<br>99<br>The development and use of green energies receive much attention because of energy crisis and climate changes. Wind energy generation plays an important role in green energy developments since it has many advantages such as low cost, no pollutions, inexhaustible supply of wind energy. Among the various types of wind power generator, squirrel-cage induction generators have been widely employed due to low costs and easy to control. However, the squirrel-cage induction generators are not capable of providing voltage regulation when the system is subjected to load
APA, Harvard, Vancouver, ISO, and other styles
36

Tu, Chun-Hung, and 凃俊宏. "Performance Assessment and DC-Link Voltage Regulation System Design of Slotless Tubular Linear Generator." Thesis, 2011. http://ndltd.ncl.edu.tw/handle/13695670925498740965.

Full text
Abstract:
碩士<br>國立中山大學<br>電機工程學系研究所<br>99<br>The aim of this thesis is to design a controllable DC-link output voltage for isolated slotless tubular linear generators (STLG), which is capable of directly harnessing wave and solar thermal energies. For supplying stable DC-link voltage to load, a suitable voltage regulation circuit is designed based on the integrate system performance assessment. Electrical and mechanical parameters in this refined STLG design are involved to analyze the operational behaviors through magnetic equivalent circuit analysis at different operating modes. From the theoretical m
APA, Harvard, Vancouver, ISO, and other styles
37

Sheen, Jinn-Chyuan, and 沈進泉. "Voltage Regulation of an Isolated Self-excited Induction Generator by using Solid-state Synchronous Condenser." Thesis, 1995. http://ndltd.ncl.edu.tw/handle/21389358019100102231.

Full text
APA, Harvard, Vancouver, ISO, and other styles
38

Gatavi, Ehsan. "Voltage regulation and reactive power compensation to improve low voltage ride-through capability for doubly fed induction generator-based wind turbine." Thesis, 2019. http://hdl.handle.net/1959.7/uws:54766.

Full text
Abstract:
Of all the renewable energies, wind power is proliferating and it now plays a significant part in the power supply. The system known as Doubly Fed Induction Generator (DFIG) is the most popular wind turbine, because it plays a very significant role in enhancing low voltage ride through (LVRT) capability. Ancillary services such as voltage control and reactive power capability are the main concerns in wind power control systems and need to be managed in detail and with great care. The lack of reactive power during a fault period can result in instability in generators and/or disconnection of a
APA, Harvard, Vancouver, ISO, and other styles
39

Dastagir, Ghulam. "Voltage and frequency regulation of a stand-alone self-excited induction generator with an unregulated prime mover." Thesis, 2008. http://spectrum.library.concordia.ca/975637/1/MR40878.pdf.

Full text
Abstract:
The squirrel-cage induction machine is very attractive for small and medium power generation schemes because of its low cost, robustness and high power density (W/kg). However, the magnitude and the frequency of the generated voltage depend upon the rotor speed, the amount of capacitive excitation, and the load in stand-alone systems with unregulated prime movers. A common approach for providing regulated voltage and frequency to the load is the use of an asynchronous link (ac-dc-ac) power electronic converter. The main disadvantage of this scheme is that the two series connected ac-dc convert
APA, Harvard, Vancouver, ISO, and other styles
40

Chauhan, Priyesh Jagdishchandra. "Investigation on various aspects of generalized impedance controller for voltage and frequency regulation of self-excited induction generator." Thesis, 2012. http://localhost:8080/xmlui/handle/12345678/6551.

Full text
APA, Harvard, Vancouver, ISO, and other styles
41

Huang, Li-Hsuan, and 黃禮宣. "A PLL-Based Clock Generator With Voltage Regulator." Thesis, 2005. http://ndltd.ncl.edu.tw/handle/50051026138818857863.

Full text
Abstract:
碩士<br>南台科技大學<br>電子工程系<br>93<br>Every product has different specification, so it is meaningless to design all specification to the best and produce high cost. This paper is to modify some circuit based on product specification in order to make balance of cost and specification. We start to study how to use the least cost to reduce Locking time and increase locking speed of phase lock loops without modifiying original circuit characteristics. In addition, VCO circuit in the system is a high pass filter. Noise of VCO will make contribution to output frequency. So, we must use technique of designi
APA, Harvard, Vancouver, ISO, and other styles
42

Huang, Jen-Wei, and 黃仁煒. "Design of Dynamic Voltage Regulator for a Grid-connected Induction Generator." Thesis, 2007. http://ndltd.ncl.edu.tw/handle/15700962748554191427.

Full text
Abstract:
碩士<br>國立臺灣大學<br>電機工程學研究所<br>95<br>As the issue of environmental protection receives increasing attention, renewable energy source, such as wind turbine-induction generator system, is getting more and more important. Three phase induction generators provide the desired electric power in a wind energy conversion system. Induction machines are not commonly employed as generators except in the case of wind farms due to their unsatisfactory voltage regulation. The purpose of this thesis is to analyze and design the Dynamic Voltage Regulator(DVR) for a wind energy conversion system with an induction
APA, Harvard, Vancouver, ISO, and other styles
43

Lin, Chang-ting, and 林昌廷. "Research on Dynamic Voltage Regulation to Doubly-Fed Wind Generators using STATCOM." Thesis, 2008. http://ndltd.ncl.edu.tw/handle/01741909645533951662.

Full text
Abstract:
碩士<br>國立中正大學<br>電機工程所<br>97<br>In this thesis, we analyze the voltage quality and stability problems for wind farm connecting to power system, and the principles of reactive power compensation. Wind generation units without proper reactive compensation devices may induce voltage fluctuations to the system. Moreover, voltage variations from transmission system may lead to voltage sags at wind generator terminal and frequent tripping would occur, which would reduce the life time of wind generators. Using fixed capacitor for reactive power compensation has some problems, for example, insufficient
APA, Harvard, Vancouver, ISO, and other styles
44

Chen, Shiang-Cong, and 陳翔琮. "Design of a Dynamic Voltage Regulator for a Squirrel-Cage Induction Generator." Thesis, 2010. http://ndltd.ncl.edu.tw/handle/40509484098556323575.

Full text
Abstract:
碩士<br>臺灣大學<br>電機工程學研究所<br>98<br>To Reduce emission, much effort has been devoted to the development of green energy techniques. Among the various types of green energy generations, wind energy conversion is studied in thesis. Squirrel-cage induction generators have been widely employed for wind energy conversion due to their low costs and high reliability. However, the squirrel-cage induction generators are not capable of providing voltage regulation due to the lack of rotor excitation. To improve the reactive power support and voltage regulation of a squirrel-cage induction generator, a dyn
APA, Harvard, Vancouver, ISO, and other styles
45

Chen, Woei-Luen, and 陳偉倫. "Design of Voltage and Frequency Regulator for a Wind Turbine-Induction Generator System." Thesis, 2006. http://ndltd.ncl.edu.tw/handle/46216037819653625990.

Full text
Abstract:
博士<br>國立臺灣大學<br>電機工程學研究所<br>94<br>Voltage regulator and frequency regulator are designed for a wind turbine-induction generator system. Much effort has been placed on control strategy exploration and controller design of the static synchronous compensator (STATCOM) and the variable blade pitch in a wind energy conversion system (WECS). An output feedback linear quadratic controller is designed for the STATCOM and the variable blade pitch in order to reach the voltage and mechanical power control. Then a systematic approach based on pole assignment technique is used to refine the weighting m
APA, Harvard, Vancouver, ISO, and other styles
46

Wu, Chun-Shien, and 吳俊賢. "Low-Cost Dual Output Voltage Level Low-dropout Linear Regulator Using a Novel MUX-based Adjustable Reference Voltage Generator." Thesis, 2008. http://ndltd.ncl.edu.tw/handle/68777859719416065521.

Full text
Abstract:
碩士<br>國立成功大學<br>電機工程學系碩博士班<br>96<br>In this thesis, we present a dual output voltage levels low drop-out (LDO) linear regulator. The regulator could produce two different output voltage levels for the same output by using an external selection signal. The proposed LDO structure is suitable for a power management system that required more than one supply voltage level with small area. The output voltage levels are 1V and 2.5V in this design. Our proposed dual output voltage level LDO linear regulator consists of a novel two-level reference voltage generator, a fast discharging path for the swit
APA, Harvard, Vancouver, ISO, and other styles
47

"Enhanced voltage regulation in lightly-loaded, meshed distribution networks using a phase shifting transformer." Thesis, 2013. http://hdl.handle.net/10210/8398.

Full text
Abstract:
M.Ing. (Electrical and Electronic Engineering)<br>Long transmission lines in power system require high line loading in order to lower voltage limits due to line losses. For relatively long lines, line charging is high and thus higher voltage limits reached at low loading. It follows then that it is a challenge to maintaining the voltages between the acceptable limits for relatively long lines. This dissertation highlights the problems experienced when load varying from very low to very high is supplied by very long parallel lines of different impedance characteristic. When the load is extremel
APA, Harvard, Vancouver, ISO, and other styles
48

Yang, Bo-Han, and 楊博涵. "Simulation and Analysis for Voltage Regulation of Control Center of a Nuclear Generation Plant." Thesis, 2011. http://ndltd.ncl.edu.tw/handle/y3d83d.

Full text
Abstract:
碩士<br>中原大學<br>電機工程研究所<br>99<br>Accident on Voltage regulator system of control center of Lunmen generation plant has occurred at 13:45 on March 31 2010. Although Taipower has conducted a preliminary investigation which result in the over –voltage as cause of the incident and requested manufacturer of CVCF to find out the reasons why this system was not stable, and to improve the system. But the working operation and the reason for over-voltage is still not clear. This research clarifies the operation phenomena of ferroresonance transformer which is adopted for the voltage regulation of CVCF by
APA, Harvard, Vancouver, ISO, and other styles
49

Yu, Wen-Yi, and 游文毅. "ANALYSIS OF CAPACITOR INSTALLATION AND VOLTAGE REGULATION FOR DISTRIBUTION POWER SYSTEM WITH DISPERSED GENERATION." Thesis, 2005. http://ndltd.ncl.edu.tw/handle/85466877166890631966.

Full text
Abstract:
碩士<br>大同大學<br>電機工程學系(所)<br>94<br>ABSTRACT The so-called Distributed Power Generation or Dispersed Power Generation System refers to small power generator that is closed to the load terminal and the power generation capacity is comparatively less. It can be formed as area power supply system or can be connected in parallel to large-scale power system. For distribution in the past, the Taipower would supply a one-way power, therefore this was simpler in respect of control, management, repair or fee collection. However, when there are many dispersed power generation systems (abbreviated as DG) on
APA, Harvard, Vancouver, ISO, and other styles
50

Chen, Wen-Cheng, and 陳文政. "A Capacitor-free Low Dropout Voltage Regulator for Portable Generators’ Back-end Application." Thesis, 2013. http://ndltd.ncl.edu.tw/handle/39880037754486369335.

Full text
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!