To see the other types of publications on this topic, follow the link: Goniometrija.

Journal articles on the topic 'Goniometrija'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 journal articles for your research on the topic 'Goniometrija.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse journal articles on a wide variety of disciplines and organise your bibliography correctly.

1

Žukauskienė, Milda, and Laimutė Samsonienė. "EISENOS TRENIRUOKLIO „EIK“ NAUDOJIMO GALIMYBĖS SENYVO AMŽIAUS ASMENIMS PO GALVOS SMEGENŲ KRAUJOTAKOS SUTRIKIMO." Health Sciences 31, no. 1 (2021): 93–103. http://dx.doi.org/10.35988/sm-hs.2021.019.

Full text
Abstract:
Svarbiausia treniruoklių savybė – universalumas, patikimumas ir plačios naudojimo galimybės. Straipsnyje aptariamas eisenos treniruoklio EIK pritaikomumas ir naudojimo galimybės senyvo amžiaus neįgaliesiems. Tyrimo tikslas – įvertinti treniruoklio EIK naudojimo galimybes asmenims, patyrusiems galvos smegenų kraujotakos sutrikimą, parengti praktines rekomendacijas. Veiklos tyrime taikyti kokybiniai ir kiekybiniai tyrimometodai: ekspertų apklausa, medicininių dokumentų analizė, testavimas (goniometrija, raumenų jėgos vertinimas, 10 m ėjimo; 6 min. ėjimo testai ir kt.), filmavimas, fotografavimas
APA, Harvard, Vancouver, ISO, and other styles
2

Simanynaitė, Augustė, Vilma Juodžbalienė, and Simona Krasuckienė. "Fizinių pratimų ir funkcinės elektrostimuliacijos poveikis kojos funkcijai po juosmeninės stuburo srities dermoidinės cistos pašalinimo. Atvejo analizė." Reabilitacijos mokslai: slauga, kineziterapija, ergoterapija 1, no. 24 (2021): 66–77. http://dx.doi.org/10.33607/rmske.v1i24.1077.

Full text
Abstract:
Tyrimo pagrindimas. Dermoidinės cistos pasitaiko retai, dažniausiai jos diagnozuojamos vaikams. Nepaisant gerybinio šių cistų pobūdžio, neurochirurginė pašalinimo operacija, galinti sukelti neurologinį deficitą, dažnai yra neišvengiama. Veiksmingas pooperacinių liekamųjų reiškinių pašalinimas arba lengvinimas bei gyvenimo kokybės gerinimas yra labai aktualūs klausimai, todėl tyrėme, ar inovatyvios technologijos, pavyzdžiui, kineziterapija derinama su funkcine elektrostimuliacija ,,Bioness L300“ padeda pasiekti reikšmingų rezultatų.
 Tyrimo tikslas. Nustatyti fizinių pratimų ir funkcinės e
APA, Harvard, Vancouver, ISO, and other styles
3

Zachovajevienė, Brigita, and Pavelas Zachovajevas. "Čiurnos mobilumo įtaka vidutinio ir vyresnio amžiaus žmonių pusiausvyrai." Sveikatos mokslai 25, no. 5 (2015): 146–51. http://dx.doi.org/10.5200/sm-hs.2015.103.

Full text
Abstract:
Tyrimo metu buvo vertinama čiurnos sąnarių judesių amplitudė, statinė ir dinaminė pusiausvyra vyresnio ir vidutinio amžiaus žmonių grupėse prieš ir po čiurnos sąnarių mobilizacijos ir blauzdos tempimo procedūros. Tiriamųjų kontingentą sudarė 61 tiriamasis. Tiriamieji pagal amžių buvo suskirstyti į dvi grupes: vidutinio ir vyresnio amžiaus. Vidutinio amžiaus grupę sudarė 30 asmenų, kurių amžiaus vidurkis buvo 54,63±2,61 metai. Vyresnio amžiaus grupę sudarė 31 asmuo, kurių amžiaus vidurkis 65,39±3,8 metai. Tyrimo metodai. Pasyviai čiurnos sąnarių judesių amplitudei vertinti – goniometrija. Stati
APA, Harvard, Vancouver, ISO, and other styles
4

Miravinskaitė, Gabrielė, and Vaida Pokvytytė. "Kineziterapijos poveikis sėdimą darbą dirbančių moterų kaklo skausmui, judesių amplitudei ir raumenų funkcijai." Reabilitacijos mokslai: slauga, kineziterapija, ergoterapija 2, no. 23 (2021): 38–50. http://dx.doi.org/10.33607/rmske.v2i23.985.

Full text
Abstract:
Tyrimo pagrindimas. Kaklo skausmas yra vienas dažniausių sėdimą darbą dirbančių žmonių sveikatos sutrikimų (Kocur et al., 2019).
 Tikslas – įvertinti ir palyginti masažo poveikį sėdimą darbą dirbančių moterų kaklo skausmui, skausmo slenksčiui, judesio baimei, giliųjų raumenų funkcijai, judesių amplitudei, funkcinės kaklo negalios lygiui ir gyvenimo kokybei.
 Metodai. Tirta 20 sėdimą darbą dirbančių moterų, kurios jautė nespecifinį kaklo skausmą. Atrankos metu į tyrimą nebuvo įtrauktos moterys, turinčios kaklinės radikulopatijos galimybę. Įvertinant tiriamųjų būklę buvo naudojami spec
APA, Harvard, Vancouver, ISO, and other styles
5

Da Silva, Rodrigo Luis Ferreira. "Comparação entre a avaliação da amplitude articular estática do cotovelo por meio de três diferentes métodos: goniometria, biofotogrametria e goniometria da imagem radiológica." Fisioterapia Brasil 10, no. 2 (2017): 106. http://dx.doi.org/10.33233/fb.v10i2.1511.

Full text
Abstract:
Introdução: O objetivo deste estudo foi verificar a confiabilidade e objetividade da goniometria e da biofotogrametria para a avaliação de uma posição do cotovelo através da comparação dos dados obtidos por estes métodos com os obtidos pela goniometria radiológica. Material e Métodos: A pesquisa contou com dezesseis indivíduos, sendo seis examinadores e dez avaliados. Para todas as técnicas de medida utilizadas, cada avaliador colheu três medidas de um mesmo ângulo do cotovelo (143º), que foi considerado como ângulo alvo das análises estatísticas e neste estudo chamado de ângulo chave. Resulta
APA, Harvard, Vancouver, ISO, and other styles
6

Iunes, Denise Hollanda. "Análise comparativa do ângulo do quadríceps medido através da goniometria e da fotogrametria computadorizada." Fisioterapia Brasil 11, no. 3 (2017): 164. http://dx.doi.org/10.33233/fb.v11i3.1373.

Full text
Abstract:
A goniometria é um método largamente utilizado nas clínicas de fi sioterapia e, atualmente, com o advento da tecnologia, a fotogrametria digital vem sendo considerada também como uma alternativa para a avaliação quantitativa das assimetrias posturais na avaliação postural. Portanto, o propósito deste estudo foi analisar e comparar o ângulo do quadríceps bilateralmente por meio da goniometria manual e da fotogrametria. Vinte e oito indivíduos foram mensurados pelo mesmo examinador, na posição ortostática e supina. Para a realização da fotografi a digital, os pontos anatômicos foram marcados com
APA, Harvard, Vancouver, ISO, and other styles
7

Tedeschi, Marcos Antonio. "Goniometria: sua prática e controvérsias." Fisioterapia Brasil 3, no. 1 (2019): 36. http://dx.doi.org/10.33233/fb.v3i1.2939.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Stratford, Paul W. "Wrist Goniometric Measurements." Physical Therapy 74, no. 7 (1994): 684–85. http://dx.doi.org/10.1093/ptj/74.7.684.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Raso, Vanessa Vilela Monte. "Análise de confiabilidade intra e interexaminadores da medida do ângulo Q na goniometria". Fisioterapia Brasil 10, № 1 (2017): 5. http://dx.doi.org/10.33233/fb.v10i1.1492.

Full text
Abstract:
A mensuração do ângulo Q é um procedimento de avaliação utilizado corriqueiramente pelos fisioterapeutas, portanto, o presente estudo teve o objetivo de analisar a confiabilidade da mensuração do ângulo Q realizado intra e interexaminadores através da goniometria. Foram analisados 30 indivíduos de ambos os sexos com idades entre 20 e 50 anos. Para captura dos dados foram utilizados os mesmos goniômetros e fitas métricas. Os resultados obtidos demonstram que não houve correlação significativa entre as análises dos diferentes examinadores em um mesmo momento, assim como também não houve correlaç
APA, Harvard, Vancouver, ISO, and other styles
10

Da Silva, Rodrigo Luis Ferreira. "Correlação entre fleximetria e goniometria radiológica para avaliações da amplitude articular estática do cotovelo." Fisioterapia Brasil 12, no. 5 (2017): 359. http://dx.doi.org/10.33233/fb.v12i5.939.

Full text
Abstract:
Este estudo objetivou determinar o grau de confiabilidade intra e interexaminador de avaliações realizadas por meio de fleximetria, e o seu grau de correlação com avaliações realizadas por goniometria radiológica. 10 indivíduos tiveram seu cotovelo direito estabilizado por chapas de ferro em ângulo fixo, que foi mensurado por 04 fisioterapeutas, com o uso de um flexímetro, em 3 dias diferentes com intervalo de uma semana entre os mesmos. Após estas avaliações, os cotovelos foram radiografados, com o mesmo ângulo estabilizado, para análise pela goniometria radiológica. Estas medidas apresentara
APA, Harvard, Vancouver, ISO, and other styles
11

Gulda, Dominika, Magdalena Drewka, and Monika Monkiewicz. "THE USE OF GONIOMETRY IN EQUESTRIAN AND CYNOLOGICAL SPORTS." Journal of Central European Agriculture 14, no. 4 (2013): 1364–73. http://dx.doi.org/10.5513/jcea01/14.4.1360.

Full text
APA, Harvard, Vancouver, ISO, and other styles
12

Santana, Levy Aniceto. "Estudo comparativo entre as medidas da goniometria e da fleximetria passiva na articulação do joelho". Fisioterapia Brasil 11, № 2 (2017): 84. http://dx.doi.org/10.33233/fb.v11i2.1346.

Full text
Abstract:
Objetivo: O objetivo deste estudo foi comparar as medidas da goniometria e da fl eximetria passiva na articulação do joelho. Metodologia: Trata-se de um estudo transversal, cuja amostra foi composta por 33 indivíduos saudáveis de ambos os sexos, 17 homens e 16 mulheres com média de idade de 21,76 ± 2,11 anos. Os instrumentos utilizados para o estudo foram o Goniômetro Universal Carci e o Flexímetro Sanny. O registro da medida da goniometria e da fl eximetria foi obtido após a fl exão passiva do joelho dominante em sua amplitude máxima com o indivíduo em decúbito ventral. Os dados foram analisa
APA, Harvard, Vancouver, ISO, and other styles
13

Ablyaeva, A. V. "Ergonomics of school workplaces as an important factor in preserving the health of adolescents." Russian Journal of Occupational Health and Industrial Ecology 60, no. 11 (2020): 707–9. http://dx.doi.org/10.31089/1026-9428-2020-60-11-707-709.

Full text
Abstract:
Introduction. Workplaces of adolescents in school may create risk factors for disorders of the musculoskeletal system, which affect the work ability and quality of future life. The aim of this study was to assess the rationality of the working posture of adolescents at school using the analysis of goniometric indicators. Materials and methods. A total of 414 jobs were studied: 244 primary school children and 170 senior school children. Plots of working postures of teenagers were constructed, and goniometric indicators were compared with the recommended ranges. Results. Almost all goniometric i
APA, Harvard, Vancouver, ISO, and other styles
14

Cherepanska, I. Yu, O. M. Bezvesilna, and A. Yu Sazonov. "Precise Intelligent Goniometric System." Visnyk of Vinnytsia Politechnical Institute 143, no. 2 (2019): 7–14. http://dx.doi.org/10.31649/1997-9266-2019-143-2-7-14.

Full text
APA, Harvard, Vancouver, ISO, and other styles
15

Whyte, Enda, Tiarnán Ó Doinn, Miriam Downey, and Siobhán O’Connor. "Reliability of a Smartphone Goniometric Application in the Measurement of Hip Range of Motion Among Experienced and Novice Clinicians." Journal of Sport Rehabilitation 30, no. 6 (2021): 969–72. http://dx.doi.org/10.1123/jsr.2020-0165.

Full text
Abstract:
Context: Deficits in the hip range of motion are associated with hip and groin injuries. Accurate and reliable goniometric measurements are important in identifying those at risk of injury and determining the efficacy of treatment interventions. Smartphone goniometric applications are regularly used to assess joint ranges of motion; however, there is limited knowledge on the reliability of this method in relation to the hip, particularly between clinicians with different levels of experience. Objective: To determine the intratester and intertester reliability of a smartphone clinometer applica
APA, Harvard, Vancouver, ISO, and other styles
16

Çelik, M. Timuçin, A. Özmen, S. Avki, and Ö. Şengöz Şirin. "Measurements of normal joint angles by goniometry in calves." Veterinary and Comparative Orthopaedics and Traumatology 27, no. 02 (2014): 120–23. http://dx.doi.org/10.3415/vcot-13-04-0046.

Full text
Abstract:
SummaryThe aim of this study was to establish normal reference values of the forelimb and hindlimb joint angles in normal Holstein calves.Thirty clinically normal Holstein calves that were free of any detectable musculoskeletal abnormalities were included in the study. A standard transparent plastic goniometer was used to measure maximum flexion, maximum extension, and range-of-motion of the shoulder, elbow, carpal, hip, stifle, and tarsal joints. The goniometric measurements were done on awake calves that were positioned in lateral recumbency. The goniometric values were measured and recorded
APA, Harvard, Vancouver, ISO, and other styles
17

Cook, James R., Nancy A. Baker, Rakié Cham, Erin Hale, and Mark S. Redfern. "Measurements of Wrist and Finger Postures: A Comparison of Goniometric and Motion Capture Techniques." Journal of Applied Biomechanics 23, no. 1 (2007): 70–78. http://dx.doi.org/10.1123/jab.23.1.70.

Full text
Abstract:
A marker-based kinematic hand model to quantify finger postures was developed and compared to manual goniometric measurements. The model was implemented with data collected from static postures of five subjects. The metacarpal phalangeal (MCP) and proximal interphalangeal (PIP) joints were positioned in flexion of approximately 30, 60, and 90 degrees for 5 subjects. Wrist flexion/extension and ulnar/radial deviations were also examined. The model-based angles for the MCP and PIP joints were not statistically equivalent to the goniometric measurements, with differences of −1.8 degrees and +3.5
APA, Harvard, Vancouver, ISO, and other styles
18

Martin, RobRoy L., and Thomas G. McPoil. "Reliability of Ankle Goniometric Measurements." Journal of the American Podiatric Medical Association 95, no. 6 (2005): 564–72. http://dx.doi.org/10.7547/0950564.

Full text
Abstract:
This article reviews the existing range-of-motion measurement literature related to ankle dorsiflexion and plantarflexion to determine whether the reliability of ankle range-of-motion measurements can be defined, how the characteristics of the study population or clinician affect reliability, and the level of responsiveness for these measures. A MEDLINE search was performed through February 2004, and 11 articles met the inclusion criteria established for this review. Ample evidence was found for intrarater reliability for ankle dorsiflexion and plantarflexion range of motion. Although some evi
APA, Harvard, Vancouver, ISO, and other styles
19

Gajdosik, Richard L. "Goniometric Measurements at the Knee." Physical Therapy 67, no. 6 (1987): 979–80. http://dx.doi.org/10.1093/ptj/67.6.979a.

Full text
APA, Harvard, Vancouver, ISO, and other styles
20

Parish, Melanie, Benjamin Bugden, and Karen PY Liu. "Psychometric properties of the goniometric assessment of the Dart Thrower’s Motion." Hand Therapy 23, no. 3 (2018): 110–16. http://dx.doi.org/10.1177/1758998318769335.

Full text
Abstract:
Introduction The Dart Thrower’s Motion is an important movement for hand function. A goniometric clinical measure of Dart Thrower’s Motion has been developed. However, its validity and reliability in people with wrist and hand injury is not known. This study investigated the inter-rater and test–retest reliability and criterion validity of the Dart Thrower’s Motion measure. Methods A cross-sectional design was used. Thirty-five participants with hand or wrist injury completed the goniometric assessment of the Dart Thrower’s Motion and goniometric wrist active range of motion assessment three t
APA, Harvard, Vancouver, ISO, and other styles
21

Chevidikunnan, Mohamed Faisal, Amer Al Saif, Harish Pai K, and Lawrence Mathias. "Comparing goniometric and radiographic measurement of Q angle of the knee." Asian Biomedicine 9, no. 5 (2017): 631–36. http://dx.doi.org/10.5372/1905-7415.0905.433.

Full text
Abstract:
AbstractBackgroundThe Q angle is a relevant clinical diagnostic measurement to detect various disorders of the knee. The common method used to measure the Q angle in the routine clinical practice is by radiography. An alternative to radiographic measurement is goniometry, by which exposure to x-rays can be avoided.ObjectivesTo compare and correlate the goniometric measurement of Q angle with radiographic measurement of the Q angle in patients with acute knee pain.MethodsWe selected 45 patient participants with a mean age of 32.5 years who satisfied the inclusion criteria for this study. All th
APA, Harvard, Vancouver, ISO, and other styles
22

Jaanson, P., F. Manoocheri, and E. Ikonen. "Goniometrical measurements of fluorescence quantum efficiency." Measurement Science and Technology 27, no. 2 (2016): 025204. http://dx.doi.org/10.1088/0957-0233/27/2/025204.

Full text
APA, Harvard, Vancouver, ISO, and other styles
23

Pino-Sánchez, Jean, Oscar Tapia-Claudio, Pamela Merino-Salazar, and Yolis Campos-Villalta. "Estudio comparativo entre la anamnesis y la ergonometría en la detección de limitaciones biomecánicas por sintomatología musculoesquelética." Investigación Clínica 62, no. 1 (2021): 52–62. http://dx.doi.org/10.22209/ic.v62n1a05.

Full text
Abstract:
El objetivo del presente estudio fue comparar las limitaciones biomecánicas encontradas, aplicando la anamnesis y la evaluación goniométrica, en trabajadores con síntomas musculoesqueléticos, y en otros asintomáticos, durante la evaluación médica periódica en una empresa ecuatoriana. Durante el 2018, se diagnosticaron y evaluaron 96 trabajadores administrativos y operativos- obreros, de una empresa manufacturera privada, mediante anamnesis y goniometría. Los resultados se compararon mediante la t de Student. En el 80% de los segmentos evaluados se hallaron diferencias estadísticas significativ
APA, Harvard, Vancouver, ISO, and other styles
24

Ocal, Mehmet, and Seyyid Sabanci. "Comparison of goniometric measurements of the stifle joint in seven breeds of normal dogs." Veterinary and Comparative Orthopaedics and Traumatology 29, no. 03 (2016): 214–19. http://dx.doi.org/10.3415/vcot-15-05-0090.

Full text
Abstract:
SummaryObjective: To compare the goniometric measurements of the stifle joint in seven dog breeds, and to determine the relationship among goniometric measurements, age, body weight, tibial plateau angle, crus and thigh circumferences, and widths of quadriceps, hamstring, and gastrocnemius muscles in healthy dogs.Methods: We used a total of 126 dogs from seven different breeds, and recorded the angle of the stifle joint at standing, extension, and flexion together with the range of motion (ROM). The circumferences of the thigh and crus were also measured. Medio -lateral radiographic projection
APA, Harvard, Vancouver, ISO, and other styles
25

Timi, Jorge Ribas, Sergio Quilici Belczak, Aline Yoshimi Futigami, and Fernando Morandini Pradella. "A anquilose tíbio-társica e sua importância na insuficiência venosa crônica." Jornal Vascular Brasileiro 8, no. 3 (2009): 214–18. http://dx.doi.org/10.1590/s1677-54492009000300005.

Full text
Abstract:
CONTEXTO: O desenvolvimento de anquilose em pacientes com insuficiência venosa crônica (IVC) pode ser evidenciado em diversos estágios da patologia através de medidas da amplitude de movimento da articulação do tornozelo tomadas com a utilização de um goniômetro. OBJETIVO: Relacionar a diminuição da amplitude de movimento da articulação tíbio-társica na IVC dos membros inferiores (MMII) medida por goniometria com a gravidade da IVC, utilizando-se a classificação CEAP. MÉTODOS: No período de março de 2003 a agosto de 2004, 86 pacientes (67 mulheres e 19 homens) com média de idade de 50,6 anos f
APA, Harvard, Vancouver, ISO, and other styles
26

Richard, Reg, Ingrid S. Parry, Alexis Santos, and W. Scott Dewey. "Burn Hand or Finger Goniometric Measurements." Journal of Burn Care & Research 38, no. 6 (2017): e960-e965. http://dx.doi.org/10.1097/bcr.0000000000000529.

Full text
APA, Harvard, Vancouver, ISO, and other styles
27

Correges, Philippe, Patrick Sors, and Yves Dunant. "Simple goniometric search for electron microscopy." Microscopy Research and Technique 36, no. 5 (1997): 440–41. http://dx.doi.org/10.1002/(sici)1097-0029(19970301)36:5<440::aid-jemt15>3.0.co;2-s.

Full text
APA, Harvard, Vancouver, ISO, and other styles
28

Riddle, Dan L., Jules M. Rothstein, and Robert L. Lamb. "Goniometric Reliability in a Clinical Setting." Physical Therapy 67, no. 5 (1987): 668–73. http://dx.doi.org/10.1093/ptj/67.5.668.

Full text
APA, Harvard, Vancouver, ISO, and other styles
29

Elveru, Robert A., Jules M. Rothstein, and Robert L. Lamb. "Goniometric Reliability in a Clinical Setting." Physical Therapy 68, no. 5 (1988): 672–77. http://dx.doi.org/10.1093/ptj/68.5.672.

Full text
APA, Harvard, Vancouver, ISO, and other styles
30

Okeke, H. "Comparison of goniometric measurement reliability of hip joint flexion and proximal interphalangeal joint flexion in healthy adults." South African Journal of Physiotherapy 55, no. 4 (1999): 24–28. http://dx.doi.org/10.4102/sajp.v55i4.578.

Full text
Abstract:
Background For many reasons’ physiotherapists measure joint range of motion of their patients. There are usually variations in measurement values of each motion when measured either by the same person or by different observers. Also, reliability studies have resulted in varying levels of reliability coefficients. The purpose of this study was to compare the goniometric measurement reliability of a complex joint represented by the hip joint and a simple joint represented by proximal interphalangeal (PIP) flexion motions and to assess whether the two joint motions could be equally reliably measu
APA, Harvard, Vancouver, ISO, and other styles
31

Dorofeev, N. V., A. V. Grecheneva, and O. R. Kuzichkin. "Complex processing of goniometric and acoustic signals in the automated control system of the rehabilitation exoskeleton." MATEC Web of Conferences 272 (2019): 01047. http://dx.doi.org/10.1051/matecconf/201927201047.

Full text
Abstract:
The technique of express-assessment of intervertebral disk changes is described. This technique is based on the automation of goniometric and arthrophonometric measurements to reduce of the trauma in the regulation and using of the rehabilitation exoskeleton. It is characterized by the application of an individual biomechanical model of a human being, built on the basis of an individual n-shaped angular model and a three-dimensional biomechanical model. The using wavelet filtering and neural network algorithms for the detection and classification of pathologies when processing of the goniometr
APA, Harvard, Vancouver, ISO, and other styles
32

WILLIAMS, N. W., J. M. T. PENROSE, C. M. CADDY, E. BARNES, D. R. HOSE, and P. HARLEY. "A Goniometric Glove for Clinical Hand Assessment." Journal of Hand Surgery 25, no. 2 (2000): 200–207. http://dx.doi.org/10.1054/jhsb.1999.0360.

Full text
Abstract:
The construction of a goniometric glove is described. Each of the sensors in the glove was calibrated over a custom built metal hand using blocks of known angles as angular references. The digital data output from each sensor of the glove were converted into angular displacements at each joint. The glove was validated for consistency of measurement and accuracy over a custom built metal jig and in the human hand. The accuracy of the glove was found to be within the limits of traditional goniometry. It is proposed that goniometric gloves could be useful in the assessment of hand function.
APA, Harvard, Vancouver, ISO, and other styles
33

Rаzinkоv, S. N., Е. А. Rеshetnyak, and E. А. Zhidko. "Measurement of the Coordinates of Radio Emission at High Frequencies by Goniometric and Goniometric-Range Finding Methods." Measurement Techniques 62, no. 12 (2020): 1056–63. http://dx.doi.org/10.1007/s11018-020-01734-y.

Full text
APA, Harvard, Vancouver, ISO, and other styles
34

Belczak, Cleusa Ema Quilici, Gildo Cavalheri Jr., José Maria Pereira de Godoy, Roberto Augusto Caffaro, and Sergio Quilici Belczak. "Relação entre a mobilidade da articulação talocrural e a úlcera venosa." Jornal Vascular Brasileiro 6, no. 2 (2007): 149–55. http://dx.doi.org/10.1590/s1677-54492007000200009.

Full text
Abstract:
CONTEXTO: O presente estudo avalia a mobilidade da articulação talocrural nos seis estágios clínicos da classificação CEAP (clínica, etiológica, anatômica e patofisiológica do International Consensus Committee Reporting Standards on Venous Disease) para doença venosa utilizando a goniometria, e detecta redução da mobilidade articular nos estágios mais avançados da doença, C5 e C6 (úlcera cicatrizada ou ativa). OBJETIVO: Investigar a existência de uma relação entre a severidade clínica da doença venosa crônica dos membros inferiores e a diminuição do grau de mobilidade da articulação talocrural
APA, Harvard, Vancouver, ISO, and other styles
35

Nicolini, Renata D´Agostini. "Programa de hidroterapia no movimento de dorsiflexão de indivíduos hemiparéticos espásticos." Fisioterapia Brasil 11, no. 1 (2017): 34. http://dx.doi.org/10.33233/fb.v11i1.1329.

Full text
Abstract:
Este trabalho foi desenvolvido com a finalidade de avaliar um programa de hidroterapia, analisando o movimento de dorsiflexão, durante a marcha, em pacientes hemiparéticos espásticos. O presente estudo caracterizou-se por apresentar paradigma quantitativo, abordagem pré-experimental com análise antes e depois em um mesmo grupo. Foram selecionados 7 indivíduos com hemiparesia espástica em decorrência de AVE (Acidente Vascular Encefálico). Os colaboradores foram submetidos a uma avaliação neurofuncional, à goniometria manual do movimento de dorsiflexão e à filmagem da marcha para análise posteri
APA, Harvard, Vancouver, ISO, and other styles
36

Nolasco, Christiane De Souza, Filipe Abdalla dos Reis, André Merjan de Figueiredo, and Érica Martinho Salvador Laraia. "Confiabilidade e aplicabilidade de dois métodos de avaliação da amplitude de movimento de dorsiflexão do tornozelo." ConScientiae Saúde 10, no. 1 (2011): 83–92. http://dx.doi.org/10.5585/conscientiaesaude/2011/v10n1/2439.

Full text
Abstract:
Introdução: A limitação da amplitude de movimento de dorsiflexão é o parâmetro mais utilizado na avaliação e evolução da abordagem fisioterapêutica. Objetivos: Avaliar a confiabilidade e aplicabilidade da goniometria e do teste Weight-Bearing para a mensuração de dorsiflexão do tornozelo. Método: Participaram 25 voluntários, do sexo masculino, com idade média de 38,81 (± 6,26), distribuídos em dois grupos: G1 (n=13 Não-atleta) e G2 (n=12 Atletas). A medida da dorsiflexão do tornozelo foi realizada com goniômetro universal adaptado com haste metálica de 45 cm e por meio do teste Weigth-Bearing.
APA, Harvard, Vancouver, ISO, and other styles
37

Jaeger, Gayle H., Denis J. Marcellin-Little, Venita DePuy, and B. Duncan X. Lascelles. "Validity of goniometric joint measurements in cats." American Journal of Veterinary Research 68, no. 8 (2007): 822–26. http://dx.doi.org/10.2460/ajvr.68.8.822.

Full text
APA, Harvard, Vancouver, ISO, and other styles
38

Gerhardt, John J., and Robert D. Rondinelli. "Goniometric Techniques for Range-of-Motion Assessment." Physical Medicine and Rehabilitation Clinics of North America 12, no. 3 (2001): 507–28. http://dx.doi.org/10.1016/s1047-9651(18)30047-0.

Full text
APA, Harvard, Vancouver, ISO, and other styles
39

Podrigalo, L. V., A. A. Volodchenko, O. A. Rovnaya, and B. Stankiewicz. "Analysis of martial arts athletes’ goniometric indicators." Physical education of students 21, no. 4 (2017): 182. http://dx.doi.org/10.15561/20755279.2017.0406.

Full text
APA, Harvard, Vancouver, ISO, and other styles
40

Potekhina, Yu P., D. R. Dautov, D. A. Goryacheva, D. V. Pavlov, and A. A. Kurnikova. "Goniometric evaluation of students’ musculoskeletal system condition." Journal of Anatomy and Histopathology 7, no. 3 (2018): 46–50. http://dx.doi.org/10.18499/2225-7357-2018-7-3-46-50.

Full text
APA, Harvard, Vancouver, ISO, and other styles
41

Fish, Dale R., and Lydia Wingate. "Sources of Goniometric Error at the Elbow." Physical Therapy 65, no. 11 (1985): 1666–70. http://dx.doi.org/10.1093/ptj/65.11.1666.

Full text
APA, Harvard, Vancouver, ISO, and other styles
42

Adair, Henry, David Levine, and Denis Marcellin-Little. "Validity and repeatability of goniometry in normal horses." Veterinary and Comparative Orthopaedics and Traumatology 29, no. 04 (2016): 314–19. http://dx.doi.org/10.3415/vcot-15-11-0182.

Full text
Abstract:
SummaryPurpose: To assess validity and inter- and intra-tester reliability of equine goniometry and to establish values for carpal, meta -carpophalangeal, tarsal, and metatarsophalangeal flexion and extension in horses.Subjects: Seventeen healthy equine subjects of varied breeds were used.Methods: Three investigators blindly and independently measured in triplicate the extension and flexion of carpal, metacarpo -phalangeal, tarsal, and metatarsophalangeal joints of 17 horses after sedation. Radiographs of these joints in flexion and extension were acquired while under sedation. Goniometric and
APA, Harvard, Vancouver, ISO, and other styles
43

De Godoy, José Maria Pereira. "Cinesioterapia na amplitude articular do ombro no pós-cirúrgico do câncer de mama." Fisioterapia Brasil 8, no. 3 (2018): 168. http://dx.doi.org/10.33233/fb.v8i3.1768.

Full text
Abstract:
Oobjetivodesteestudofoiavaliaraeficáciadosexercíciosterapêuticosnaaquisiçãodeamplitudearticulardoombropós-tratamento cirúrgico docâncerdemama. Participaram dapesquisa12mulheressubmetidas amastectomia(sete) e quadrantectomia (cinco). A goniometria foi utilizadaparaavaliação deamplitudearticulardoombro,anteseapósaexecuçãodoprogramadeexercícios. A cinesioterapia foi realizadapordozesemanas,emsessõesde quarenta ecincominutos, duasvezesporsemana.Paraanálisedosresultadosfoi utilizadaporcentagememédia. Àprimeiraavaliação, todas aspacientesapresentaramlimitaçãoarticulardoombronaflexãoequasetodas naabd
APA, Harvard, Vancouver, ISO, and other styles
44

Carvalho, Alberito Rodrigo de, Márcio Edyr Rahn, Maiara Diedrichs, et al. "Concordância inter-observador em testes de avaliação proprioceptiva do joelho por goniometria." Fisioterapia e Pesquisa 17, no. 1 (2010): 7–12. http://dx.doi.org/10.1590/s1809-29502010000100002.

Full text
Abstract:
O propósito deste foi determinar o grau de concordância inter-avaliador de dois testes que mensuram a propriocepção do joelho por meio da goniometria, em uma amostra de universitárias (n=13; 23,8±6,4 anos). Mensurou-se a acurácia proprioceptiva pelos testes de percepção do limiar de movimento passivo lento (T1), movendo-se passivamente a perna até o ângulo alvo; e pelo teste de senso de posição articular (T2), solicitando-se movimento ativo até o ângulo alvo, previamente atingido passivamente. Os ângulos alvos foram sorteados e as medições feitas simultaneamente, de forma cega, por dois avalia
APA, Harvard, Vancouver, ISO, and other styles
45

Ribeiro Neto, Nelson Coimbra, Hélio Gustavo Santos, Brenda Carreiro, Gleica Prenholato Dias Campanha, Lorena Liduíno, and Isaías Leal. "Ocorrência de Lesões de Punho e Mão e Análise Álgica em Praticantes de Jiu-jítsu." Saúde e Pesquisa 9, no. 2 (2016): 283. http://dx.doi.org/10.17765/1983-1870.2016v9n2p283-290.

Full text
Abstract:
No jiu-jítsu predominam técnicas de luta sobre a imposição da força bruta e, juntamente com os princípios biomecânicos, otimiza a força muscular do lutador, anula a do oponente e utiliza as valências físicas deste contra ele próprio. Desse modo, buscou-se identificar a ocorrência de lesões de punho e mão e análise da dor em praticantes de jiu-jítsu. Esta é uma pesquisa de campo, descritiva, de análise quali-quantitativa, com 6 participantes avaliados em sua preensão palmar, goniometria de punho, além dos testes de Phalen e Finkelstein e aplicação da Escala Visual Analógica, diagrama corporal e
APA, Harvard, Vancouver, ISO, and other styles
46

Anselmi-Tamburini, Umberto, Paolo Lupotto, and Giorgio Spinolo. "An Electronic Driver for the Automatic Divergence Slit Attachment of Commercial Diffractometers." Powder Diffraction 5, no. 4 (1990): 192–94. http://dx.doi.org/10.1017/s0885715600015773.

Full text
Abstract:
AbstractThe paper describes a stepping motor unit which can replace the mechanical connection between a goniometric circle (ϑ or 2ϑ) and the rotatory movement of the Automatic Divergence Slit attachment.
APA, Harvard, Vancouver, ISO, and other styles
47

Souza, Soraia Figueiredo de, Alexandre Mazzanti, Alceu Gaspar Raiser, et al. "Estimulação elétrica neuromuscular em cães submetidos à imobilização rígida temporária da articulação fêmoro-tíbio-patelar." Ciência Rural 37, no. 1 (2007): 165–70. http://dx.doi.org/10.1590/s0103-84782007000100026.

Full text
Abstract:
Com o objetivo de avaliar o efeito da estimulação elétrica neuromuscular (EENM) de baixa freqüência sobre o músculo vasto lateral, foram utilizados 11 cães, agrupados aleatoriamente em três grupos, denominados de I ou controle, de II (EENM após imobilização) e de III (EENM durante e após imobilização). A articulação fêmoro-tíbio-patelar direita foi imobilizada por 30 dias pelo método de transfixação percutânea tipo II. Os cães do grupo III iniciaram as sessões de eletroterapia, três vezes por semana, durante (30 dias) e após a imobilização (60 dias); e os cães dos grupos II após a remoção da i
APA, Harvard, Vancouver, ISO, and other styles
48

Rаzinkоv, Sergey N., Еvgeniy А. Rеshetnyak, and Elena А. Zhidko. "Measurement of coordinates of sources of radio emission at high frequencies goniometric and goniometric and range-metering by methods." Metrologiya, no. 4 (2019): 33–50. http://dx.doi.org/10.32446/0132-4713.2019-4-33-50.

Full text
APA, Harvard, Vancouver, ISO, and other styles
49

Smith, RP, JJ Dias, A. Ullah, and B. Bhowal. "Visual and Computer Software-Aided Estimates of Dupuytren'ss Contractures: Correlation with Clinical Goniometric Measurements." Annals of The Royal College of Surgeons of England 91, no. 4 (2009): 296–300. http://dx.doi.org/10.1308/003588409x359259.

Full text
Abstract:
INTRODUCTION Corrective surgery for Dupuytren's disease represents a significant proportion of a hand surgeon's workload. The decision to go ahead with surgery and the success of surgery requires measuring the degree of contracture of the diseased finger(s). This is performed in clinic with a goniometer, pre- and postoperatively. Monitoring the recurrence of the contracture can inform on surgical outcome, research and audit. PATIENTS AND METHODS We compared visual and computer software-aided estimation of Dupuytren's contractures to clinical goniometric measurements in 60 patients with Dupuytr
APA, Harvard, Vancouver, ISO, and other styles
50

Lewis, E., L. Fors, and W. J. Tharion. "Interrater and Intrarater Reliability of Finger Goniometric Measurements." American Journal of Occupational Therapy 64, no. 4 (2010): 555–61. http://dx.doi.org/10.5014/ajot.2010.09028.

Full text
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!