Academic literature on the topic 'Harmonic Distortion'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Harmonic Distortion.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Harmonic Distortion"

1

R, Vikram Ragave, Sridhar Babu S.P, Rahul M, and Ravichandran C.S. "Design and Development of Three Phase Detuned Filter Reactor for Reduction of Harmonic Distortion in Power Systems." June 2023 5, no. 2 (June 2023): 212–25. http://dx.doi.org/10.36548/jei.2023.2.008.

Full text
Abstract:
Harmonics refers to a form of electrical distortion that can adversely impact power systems, electrical equipment, and the overall quality of power supply. The presence of non-linear loads, such as electronic devices, can cause the current waveform to deviate from the ideal sine wave, resulting in higher frequency currents that are multiples of the fundamental frequency. These distortions can lead to several negative effects, such as reduced power factor, increased energy losses, equipment overheating, and electromagnetic interference. These, in turn, can lower system efficiency, increase energy consumption, and escalate equipment maintenance costs. Several approaches have been developed to address the adverse effects of harmonics, such as the use of filters, capacitors, and other reactive components. These techniques aim to minimize harmonic distortion and improve power supply quality. This paper examines the effectiveness of a 1kVAr detuned reactor in mitigating harmonic distortion in power systems and electrical components. The detuned filter reactor reduces the harmonic distortion actively. It does so by monitoring the harmonic content of the power and injecting a counteracting current to cancel out the harmonic frequencies, creating a subtle "detuning" effect that reduces harmonic distortion. Detuned filter reactors find extensive application in radio and audio equipment, among other fields.
APA, Harvard, Vancouver, ISO, and other styles
2

Korzhuk, M. S., V. A. Akulinin, M. V. Zabolotnykh, and V. M. Korzhuk. "Biodistortiometry as a new method for determining the properties of agricultural products." IOP Conference Series: Earth and Environmental Science 954, no. 1 (January 1, 2022): 012040. http://dx.doi.org/10.1088/1755-1315/954/1/012040.

Full text
Abstract:
Abstract The development of new methods for the study of agricultural products is an actual task. A large number of studies on the electrical properties of biological objects are performed today for scientific and industrial purposes. Distortions of electric signals are considered conventionally as harmful. The authors performed test-bench analysis of harmonic distortion, produced by different agricultural products. Apple, banana, tomato, tangerine were tested. The digital source of sinusoidal signals and a computed spectrum analyzer were main components of the test-bench circuit. Results of measurements of harmonics, from first to tenth, were presented in a graphic form. Each kind of agricultural products created harmonic distortion with an authentic set and a level of harmonics. So, the authors have shown the ability of analyzing harmonic distortions to determine properties of agricultural products.
APA, Harvard, Vancouver, ISO, and other styles
3

Belchior, Fernando Nunes, Paulo Fernando Ribeiro, and Frederico Marques Carvalho. "Comparative Analysis of Instruments Measuring Time Varying Harmonics." International Journal of Emerging Electric Power Systems 17, no. 4 (August 1, 2016): 463–69. http://dx.doi.org/10.1515/ijeeps-2015-0175.

Full text
Abstract:
Abstract This paper aims to evaluate the performance of commercial class A and class S power quality (PQ) instruments when measuring time-varying harmonics. By using a high precision programmable voltage and current source, two meters from different manufacturers are analyzed and compared. Three-phase voltage signals are applied to PQ instruments, considering 3 situations of time-varying harmonic distortions, whose harmonic distortion values are in accordance with typical values found in power systems. This work is relevant considering that international standardization documents do not pay much attention to this aspect of harmonic distortion.
APA, Harvard, Vancouver, ISO, and other styles
4

Ayub, Munirah, Chin Kim Gan, and Aida Fazliana Abdul Kadir. "Harmonic Performance of Grid-Connected PV System under Various Penetration Levels." Applied Mechanics and Materials 699 (November 2014): 486–91. http://dx.doi.org/10.4028/www.scientific.net/amm.699.486.

Full text
Abstract:
This paper studies the harmonic performance of grid-connected PV system under various penetration levels. The system under study was modelled in MATLAB/Simulink environment. Current and voltage distortions were studied in terms of the percentage of Total Harmonic Distortion (THD) under different PV penetration scenarios. The results showed that the Grid-Connected PV generates a different level of harmonics distortion depending on the PV penetration level that was injected to the grid.
APA, Harvard, Vancouver, ISO, and other styles
5

Chua, Kein Huat, Dick Sang Hoo, Yun Seng Lim, Mohammad BabrdelBonab, Li Wang, and Pei Yin Wong. "Harmonic Analysis of a Third Rail Systems: A Case Study in Malaysia." Journal of Electronics and Advanced Electrical Engineering 1, no. 2 (May 3, 2021): 26–33. http://dx.doi.org/10.47890/jeaee/2020/keinhuatchua/11120010.

Full text
Abstract:
Harmonic distortion is one of the most important power quality issues in third rail electrification systems. The use of rectifiers and inverters in the third rail system can inject a significant amount of harmonic distortion to the electrical network. This paper aims to investigate the harmonic distortions for a DC urban third rail system at various operating conditions. The electrical network of Mass Rapid Transit Line 2 (MRT 2) Malaysia is modelled using ETAP software. The model had considered the effect of the inter-phase transformer in the 12-pulse rectifier. The current injection method is used to measure harmonic distortion at Point of Common Coupling (PCC) at the 132 kV and 33 kV buses. A normal and degraded operating conditions of power supply are investigated. From the simulation results, it is found that the 11th and 13th order harmonics have exceeded the statutory limit at 33 kV network for the normal operating condition. For the degraded operating condition, only the 11th harmonic order has exceeded the statutory limit. Keywords: Harmonic Distortion; DC Urban Rail; Various Operating Conditions
APA, Harvard, Vancouver, ISO, and other styles
6

Pielahn, M., K. Mudunkotuwa, and Dharshana Muthumuni. "Modeling Solar Converters for Harmonic and Resonance Studies." International Journal of Smart Grid and Sustainable Energy Technologies 1, no. 1 (December 17, 2019): 10–13. http://dx.doi.org/10.36040/ijsgset.v1i1.181.

Full text
Abstract:
Solar and renewable plants are increasingly being added to national grids. One technical drawback of renewable generators is that they tend to cause a significant harmonic distortion of the current and voltage waveforms. The harmonic distortions are amplified when the natural resonances of the grid interact with the injected harmonics from the power electronic based PV generation. A sustained harmonic distortion can lead to equipment failure, reduced plant output or a complete plant shutdown. Therefore, it is important to study harmonic interactions and resonance issues using fully detailed EMT models before the commissioning of a renewable plant. This paper outlines important features of modelling solar converters for the use of harmonic and resonance studies.
APA, Harvard, Vancouver, ISO, and other styles
7

Carvalho, Cesar Augusto Belchior, Genaro Mariniello da Silva, Bruna Cardoso Paz, Sylvain Barraud, Maud Vinet, Olivier Faynot, and Marcelo Antonio Pavanello. "Performance and Analysis of n-Type Vertically Stacked Nanowires Regarding Harmonic Distortion." Journal of Integrated Circuits and Systems 15, no. 2 (August 11, 2020): 1–5. http://dx.doi.org/10.29292/jics.v15i2.202.

Full text
Abstract:
This paper studies the harmonic distortion (or non-linearity) of vertically stacked SOI nanosheets with different fin widths and channel lengths. The total harmonic distortion and third order harmonic distortion are used as figures of merit in this work. The four approaches applied verifies the correlation between the harmonic distortions and the variety of transistor’s dimensions available for analysis.
APA, Harvard, Vancouver, ISO, and other styles
8

Al-Sharif, Yahya M., Gamal M. Sowilam, and Tamer A. Kawady. "Harmonic Analysis of Large Grid-Connected PV Systems in Distribution Networks: A Saudi Case Study." International Journal of Photoenergy 2022 (November 23, 2022): 1–14. http://dx.doi.org/10.1155/2022/8821192.

Full text
Abstract:
The increasing penetration of grid-connected PV rooftops at the distribution level still entails significant technical challenges affecting seriously the power quality indices such as harmonics and voltage fluctuations. Owing to the intermittent nature of renewable resources, the changing incident energy from renewables can generate considerable amounts of harmonics. Moreover, power electronic devices and nonlinear loads that are used frequently in the industry may exaggerate the harmonic distortions as well. Accordingly, utilizing suitable filtration techniques for harmonic reduction is crucial. In order to evaluate the impacts of grid-connected PVs in modern grids, a case study on power quality and voltage profile is conducted with a large grid-connected PV microgrid of 9570 kW, feeding a large hospital project in Saudi Arabia as an initial phase of implementing this project in the future. For eliminating the possible increase in harmonic distortion, a single-tuned filter is used to cope with the permissible limits according to the known IEEE standards. This filtering technique is chosen due to its advantages including the simplicity, suitability for significant integer harmonic orders, and low cost. For evaluation tests, a detailed simulation is developed by the ETAP program for the overall selected project as well as the aimed PV subsystem. Several simulation tests are conducted to investigate the harmonic distortion problem. The results show a significant reduction in the individual harmonic distortion (IHD) and the total harmonic distortion (THD) below 8% according to considered IEEE standards for LV networks. Both 6 and 12 pule inverters are considered. This is considered an important step in the realization of such large PV projects in the field.
APA, Harvard, Vancouver, ISO, and other styles
9

Meriläinen, Esa. "Comparative Measurements on Loudspeaker Distortion: Current vs. Voltage Control." Archives of Acoustics 42, no. 1 (March 1, 2017): 71–81. http://dx.doi.org/10.1515/aoa-2017-0008.

Full text
Abstract:
Abstract Modulation and harmonic distortion produced by ordinary moving-coil direct-radiator drive units are measured under current control and voltage control. A realistic two-tone test signal is used to investigate the detrimental effect of the voice coil electromotive forces on the voltage-to-current conversion that is critical with voltage control. Dramatic improvements in distortion performance are obtained with current control. Current nonlinearities in voltage-controlled speakers are shown to be the dominant source of modulation and odd harmonic distortions at signal frequencies above the fundamental resonance region. Currents in conductive voice coil formers also seem to be significant sources of distortion; with current control and non-conductive formers, odd harmonics and related modulation products virtually vanished in the upper midrange.
APA, Harvard, Vancouver, ISO, and other styles
10

Hoo, Dick Sang, Kein Huat Chua, Yun Seng Lim, Boon Han Lim, Mohammad Babrdel Bonab, and Li Wang. "Mitigation of harmonic distortions in third rail electrical systems." International Journal of Power Electronics and Drive Systems (IJPEDS) 14, no. 1 (March 1, 2023): 348. http://dx.doi.org/10.11591/ijpeds.v14.i1.pp348-357.

Full text
Abstract:
<span lang="EN-US">The extensive use of power electronic converters in the third rail system increases the harmonic distortions on the rail electrical feeding systems. Electrical machines and transformers could be overheated causing premature failures of the devices. It is therefore important to address the harmonic distortions on the electrical networks during real-time operation, which includes the degraded operation, not just the normal operation. In this paper, the harmonic distortions of a third rail system are investigated using electrical transient and analysis program (ETAP) simulation software. Four operating scenarios, namely the normal operation and three degraded operations, are considered in the studies. The degraded operations occur when one of the bulk supply transformers or 33 kV feeders is out of service. The findings of the studies showed that the 11<sup>th</sup> and 13<sup>th</sup> order harmonics are the dominant harmonic orders due to the use of 12-pulse rectifiers on the third rail system. Single-tuned harmonic filters are designed and placed in the 33 kV feeders to mitigate the individual voltage harmonic distortion (IHD<sub>v</sub>) and the total voltage harmonic distortion (THD<sub>v</sub>) so that it is within the statutory of IEEE 519:2014.</span>
APA, Harvard, Vancouver, ISO, and other styles
More sources

Dissertations / Theses on the topic "Harmonic Distortion"

1

Farooq, Haroon. "Investigating the harmonic distortion in distribution systems." Thesis, Glasgow Caledonian University, 2012. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.572811.

Full text
Abstract:
Newer technologies like Electric Vehicles (EVs) and Distributed Generation (DG) are being viewed as potential harmonic distortion threats for the distribution systems which are already facing increased harmonic stress due to the increased use of the non-linear home appliances in the recent years. Therefore, it is necessary to evaluate and analyze the harmonic distortion due to the various non-linear home appliances, EV battery chargers and DG inverters to give a clear picture of the future scenario. So that future technologies can be accommodated in the distribution systems while the existing harmonic distortion threats are dealt with. This research work investigates the harmonic spectrums of various non-linear residential loads, battery chargers and DG inverters which are then deployed to perform various simulations of the distribution systems, using Electrical Transient Analyzer Program (ET AP), considering several different scenarios. A high penetration level of non-linear residential loads is considered to simulate the current scenario. The results show high level of harmonic distortion at the Point of Common Coupling (PCC). The investigation is then extended to simulate the future scenarios by considering advent of the EV s and DG. The results indicate a significant increase in the Total Harmonic Distortion in the Voltage (THDv) in the presence of EVs and DG, at the PCC. Currently, Demand Side Management (DSM) strategies are primarily being designed based upon the daily load profile only. This research work gives a different perspective for the DSM based upon "Daily Harmonic Profile" developed by combining the experimental and simulation results. The results indicate that throughout the day, the THDv has a value of more than 1.5 % with per hour average THDv being equal to 3.25 %. The-situation worsens if the increased winter loading is considered to investigate the daily harmonic profile. This research work also explores the potential impacts of the developed profile on the DSM schemes to control the harmonic distortion in the future distribution systems.
APA, Harvard, Vancouver, ISO, and other styles
2

Jones, Kevin David. "Harmonic distortion correction using active power line conditioners." Thesis, Monterey, Calif. : Springfield, Va. : Naval Postgraduate School ; Available from National Technical Information Service, 1995. http://handle.dtic.mil/100.2/ADA300873.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Panigada, Andrea. "Harmonic distortion correction in pipelined analog to digital converters." Diss., [La Jolla] : University of California, San Diego, 2009. http://wwwlib.umi.com/cr/ucsd/fullcit?p3355107.

Full text
Abstract:
Thesis (Ph. D.)--University of California, San Diego, 2009.
Title from first page of PDF file (viewed June 10, 2009). Available via ProQuest Digital Dissertations. Vita. Includes bibliographical references.
APA, Harvard, Vancouver, ISO, and other styles
4

Dalvi, Mahesh. "Computer controlled generation of PWM waveform using harmonic distortion minimization scheme." Ohio : Ohio University, 1997. http://www.ohiolink.edu/etd/view.cgi?ohiou1177442328.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Thunberg, Erik. "On the Benefit of Harmonic Measurements in Power Systems." Doctoral thesis, Stockholm, 2001. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-3219.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Arvidsson, Marcus, and Daniel Karlsson. "Attenuation of Harmonic Distortion in Loudspeakers Using Non-linear Control." Thesis, Linköpings universitet, Reglerteknik, 2012. http://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-78645.

Full text
Abstract:
The first loudspeaker was invented almost 150 years ago and even though much has changed regarding the manufacturing, the main idea is still the same. To produce clean sound, modern loudspeaker consist of expensive materials that often need advanced manufacturing equipment. The relatively newly established company Actiwave AB uses digital signal processing to enhance the audio for loudspeakers with poor acoustic properties. Their algorithms concentrate on attenuating the linear distortion but there is no compensation for the loudspeakers' non-linear distortion, such as harmonic distortion. To attenuate the harmonic distortion, this thesis presents controllers based on exact input-output linearisation. This type of controller needs an accurate model of the system. A loudspeaker model has been derived based on the LR-2 model, an extension of the more common Thiele-Small model. A controller based on exact input-output linearisation also needs full state feedback, but since feedback risk being expensive, state estimators were used. The state estimators were based on feed-forward or observers using the extended Kalman filter or the unscented Kalman filter. A combination of feed-forward state estimation and a PID controller were designed as well. In simulations, the total harmonic distortion was attenuated for all controllers up to 180 Hz. The simulations also showed that the controllers are sensitive to inaccurate parameter values in the loudspeaker model. During real-life experiments, the controllers needed to be extended with a model of the used amplifier to function properly. The controllers that were able to attenuate the harmonic distortion were the two methods using feed-forward state estimation. Both controllers showed improvement compared to the uncontrolled case for frequencies up to 40 Hz.
APA, Harvard, Vancouver, ISO, and other styles
7

Lee, J. H. "Two-dimensional modelling and harmonic distortion analysis of bipolar transistors." Thesis, Brunel University, 1986. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.356585.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Seitz, Jeffrey L. "An interactive CD-ROM to teach harmonic and intermodulation distortion." Virtual Press, 1997. http://liblink.bsu.edu/uhtbin/catkey/1048367.

Full text
Abstract:
This study had two purposes: first, to collect information relating to harmonic and intermodulation distortion from several sources into one comprehensive report and second, to describe and develop an interactive CD-ROM as a new method of learning harmonic and intermodulation distortion. The CD-ROM allows students to interact and control the percentage amount of harmonic and intermodulation distortion in order to "calibrate" their ears. In addition, the practical testing environment changes on a random basis to continually challenge the users. These situations allow students to interact at their own speed and therefore customize their learning development.
School of Music
APA, Harvard, Vancouver, ISO, and other styles
9

Gedo, Christopher N. "Computer analysis of harmonic distortion in electrical power distribution systems." Thesis, Monterey, California. Naval Postgraduate School, 1991. http://hdl.handle.net/10945/28056.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Duggan, E. "Measurement, analysis and mathematical modelling of harmonic distortion in power systems." Thesis, Staffordshire University, 1990. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.232907.

Full text
APA, Harvard, Vancouver, ISO, and other styles
More sources

Books on the topic "Harmonic Distortion"

1

Gedo, Christopher N. Computer analysis of harmonic distortion in electrical power distribution systems. Monterey, Calif: Naval Postgraduate School, 1991.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
2

Wu, Tsu-Yin. Effect of carrier heating on the second order harmonic distortion in CATV semiconductor lasers. Leicester: De Montfort University, 1998.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
3

Paice, D. A. Power electronic converter harmonics: Calculations and multipulse methods. Palm Harbor, Fla. (114 Rosewood Ct., Palm Harbor 34685): Paice and Associates, 1994.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
4

Paice, D. A. Power electronic converter harmonics: Multipulse methods for clean power. Piscataway, NJ: IEEE Press, 1996.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
5

Paulo, Ribeiro, ed. Time-varying waveform distortions in power systems. Chichester, West Sussex, U.K: Wiley, 2009.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
6

Zhou, Clarence. 16-Channel Low Harmonic Distortion High-Voltage Analog Switches. Microchip Technology Incorporated, 2019.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
7

Zhou, Clarence. Low Harmonic Distortion, 32-Channel SPST, High-Voltage Analog Switch. Microchip Technology Incorporated, 2018.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
8

Elmenzo, Marlene. Low Harmonic Distortion, 24-Channel SPST High Voltage Analog Switch. Microchip Technology Incorporated, 2016.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
9

Zhou, Clarence. Low Harmonic Distortion, 24-Channel SPST High Voltage Analog Switch. Microchip Technology Incorporated, 2018.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
10

Wolters-Broder, Lisa. AN2303 - 4-Channel Integrated Ultrasound Pulser HV7321 Second Harmonic Distortion Measurement. Microchip Technology Incorporated, 2016.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
More sources

Book chapters on the topic "Harmonic Distortion"

1

Weik, Martin H. "harmonic distortion." In Computer Science and Communications Dictionary, 713. Boston, MA: Springer US, 2000. http://dx.doi.org/10.1007/1-4020-0613-6_8241.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Weik, Martin H. "single-harmonic distortion." In Computer Science and Communications Dictionary, 1596. Boston, MA: Springer US, 2000. http://dx.doi.org/10.1007/1-4020-0613-6_17522.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Weik, Martin H. "total harmonic distortion." In Computer Science and Communications Dictionary, 1798. Boston, MA: Springer US, 2000. http://dx.doi.org/10.1007/1-4020-0613-6_19767.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Weik, Martin H. "frequency harmonic distortion." In Computer Science and Communications Dictionary, 649. Boston, MA: Springer US, 2000. http://dx.doi.org/10.1007/1-4020-0613-6_7645.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Wakileh, George J. "Limits of Harmonic Distortion." In Power Systems, 137–44. Berlin, Heidelberg: Springer Berlin Heidelberg, 2001. http://dx.doi.org/10.1007/978-3-662-04343-1_6.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Weik, Martin H. "modulation-frequency harmonic distortion." In Computer Science and Communications Dictionary, 1038. Boston, MA: Springer US, 2000. http://dx.doi.org/10.1007/1-4020-0613-6_11729.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Radulov, Georgi, Patrick Quinn, Hans Hegt, and Arthur van Roermund. "New Harmonic-Distortion-Suppression Method." In Smart and Flexible Digital-to-Analog Converters, 177–83. Dordrecht: Springer Netherlands, 2011. http://dx.doi.org/10.1007/978-94-007-0347-6_13.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Eargle, John M. "Second Harmonic Distortion in Horns." In Electroacoustical Reference Data, 90–91. Boston, MA: Springer US, 1994. http://dx.doi.org/10.1007/978-1-4615-2027-6_44.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Afanas’eva, Elena, and Anatoly Golberg. "Topological mappings of finite area distortion." In Harmonic Analysis and Partial Differential Equations, 15–43. Cham: Springer Nature Switzerland, 2023. http://dx.doi.org/10.1007/978-3-031-25424-6_2.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Zhang, Xueyuan, and Dominik Moosbauer. "Application of Harmonic and Total Harmonic Distortion Instrumentation in Corrosion." In Advances in Electrochemical Techniques for Corrosion Monitoring and Laboratory Corrosion Measurements, 160–79. 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959: ASTM International, 2019. http://dx.doi.org/10.1520/stp160920170220.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Conference papers on the topic "Harmonic Distortion"

1

Morrison, R. E. "Harmonic distortion in commercial establishments." In IEE Colloquium on Sources and Effects of Harmonic Distortion in Power Systems. IEE, 1997. http://dx.doi.org/10.1049/ic:19970546.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Yacamini, R. "Overview on sources of harmonic distortion." In IEE Colloquium on Sources and Effects of Harmonic Distortion in Power Systems. IEE, 1997. http://dx.doi.org/10.1049/ic:19970544.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Manjaly, Anna Davis, and Justin King. "Probabilistic Poly Harmonic Distortion Model." In 2021 16th European Microwave Integrated Circuits Conference (EuMIC). IEEE, 2022. http://dx.doi.org/10.23919/eumic50153.2022.9783670.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Bennett, P. C. "The effects of harmonic distortion on equipments." In IEE Colloquium on Sources and Effects of Harmonic Distortion in Power Systems. IEE, 1997. http://dx.doi.org/10.1049/ic:19970548.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Hussein, Abdelrahman Farouk. "Proposal - Harmonic Mitigation Challenges in Unconventional ESP Applications." In SPE Middle East Artificial Lift Conference and Exhibition. SPE, 2022. http://dx.doi.org/10.2118/206918-ms.

Full text
Abstract:
Abstract Permian oil producers are facing increasing pressure from electric utilities to reduce power system harmonics, and the consequences for non-compliance can be severe. This paper details the results of a field-scale effort to reduce harmonics for a ChampionX UNBRIDLED® ESP Systems customer in the Permian basin, and how proper application and troubleshooting of harmonic filters exceeded customer and utility goals. Electric utilities have long understood that variable speed drives (VSDs) are a significant source of harmonic distortion. However, distortion limits generally have not been imposed on oil producers because utilities have not been significantly impacted, until now. Due to the large number of VSDs currently operating in the Permian basin (predominantly 6- pulse drives), the harmonics problem for utilities has reached a tipping point. In some locations, distortion of the power grid has become so severe that utilities are no longer able to communicate with smart metering devices – such devices are essential for utility billing and loss of communication with even one of these devices is a serious issue. As a result, Permian utilities have begun mandating harmonic distortion limits, as well as setting deadlines to complete harmonic remediation work. Failure to meet the utility mandates can result in severe consequences for oil producers, including disconnection of electric service or heavy penalties.
APA, Harvard, Vancouver, ISO, and other styles
6

Imarazene, Khoukha, El Madjid Berkouk, and Hachemi Chekireb. "Selective harmonics elimination: PWM method versus optimized total harmonic distortion." In 2013 IV International Conference on Power Engineering, Energy and Electrical Drives (POWERENG). IEEE, 2013. http://dx.doi.org/10.1109/powereng.2013.6635622.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Chang-Song Li, Zhi-Xuan Bai, Xian-Yong Xiao, Ya-Mei Liu, and Yi Zhang. "Research of harmonic distortion power for harmonic source detection." In 2016 17th International Conference on Harmonics and Quality of Power (ICHQP). IEEE, 2016. http://dx.doi.org/10.1109/ichqp.2016.7783437.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Downs, S. P. C. "Harmonic measurements on transmission systems." In IEE Colloquium on Sources and Effects of Harmonic Distortion in Power Systems. IEE, 1997. http://dx.doi.org/10.1049/ic:19970547.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Ras, P., M. Daly, and G. Baeten. "Harmonic distortion in slip sweep records." In SEG Technical Program Expanded Abstracts 1999. Society of Exploration Geophysicists, 1999. http://dx.doi.org/10.1190/1.1821095.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Danstrom, Eric. "Indirect Measurement of Total Harmonic Distortion." In International Congress & Exposition. 400 Commonwealth Drive, Warrendale, PA, United States: SAE International, 1990. http://dx.doi.org/10.4271/900240.

Full text
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography