To see the other types of publications on this topic, follow the link: HUMIDITY IN BUILDINGS.

Dissertations / Theses on the topic 'HUMIDITY IN BUILDINGS'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 dissertations / theses for your research on the topic 'HUMIDITY IN BUILDINGS.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

Sinclair, L. H. "Heat and moisture transfer across multilayer walls under varying temperature and humidity conditions." Thesis, University of Brighton, 1988. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.233446.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Yardım, Bülent Tunçoku Sarp. "Examination of dampness problems of a historic house/." [s.l.]: [s.n.], 2006. http://library.iyte.edu.tr/tezler/master/mimarirestorasyon/T000539.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Basmaci, Benjamin. "Improving indoor thermal comfort in residential buildings in Andean regions of Peru." Thesis, KTH, Hållbar utveckling, miljövetenskap och teknik, 2018. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-248456.

Full text
Abstract:
In the Peruvian Andes, inadequate housing represents an important problem for the local rural people. Over 3000 meters above sea level, communities suffer from very low indoor temperatures this becomes an issue which affects the health and indoor thermal comfort of the building. At early winter mornings, outdoor temperatures can occasionally go down to -15°C and indoor temperatures can drop below zero. Previous work in the field has been done by the Pontifical Catholic University of Peru PUCP, to address thermal comfort in Langui, Peru involving participatory design techniques, multidisciplina
APA, Harvard, Vancouver, ISO, and other styles
4

Lee, Song-Yng. "Adsorption of moisture and indoor pollutants on a mixed-adsorbent /." free to MU campus, to others for purchase, 1997. http://wwwlib.umi.com/cr/mo/fullcit?p9841165.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Buchta, Stanislav. "Dřevo a vnitřní prostředí staveb." Doctoral thesis, Vysoké učení technické v Brně. Fakulta stavební, 2014. http://www.nusl.cz/ntk/nusl-233823.

Full text
Abstract:
The present doctoral thesis engages in an internal environment of wooden buildings. Currently, the specialists endeavour to design and realize this type of buildings as low-energy consuming. In an effort, they minimize the thermal losses by reduction of heat transfer coefficient of external walls and reduction or elimination of their air permeability. Not always structural and technical requirements of this kind of buildings are satisfied and also a sanitary and health protection is not fully sustained. Increase in a relative air humidity of internal environment has a negative impact on moistu
APA, Harvard, Vancouver, ISO, and other styles
6

Procházková, Adéla. "Energetické hodnocení budovy pro občanskou vybavenost obce." Master's thesis, Vysoké učení technické v Brně. Fakulta stavební, 2016. http://www.nusl.cz/ntk/nusl-240433.

Full text
Abstract:
The aim of thesis is the energy evaluation of building for public facilities - kindergarten. From the beginning work deals with the analysis of a given topic, standard and legal regulations associated with the topic. This knowledge is further applied to a specific building. It follows by evaluation of the current state of the building, its systems, internal environment and analysis of measures leading to energy savings and ensuring the quality of the indoor environment of building. Work also deals with experimental measurements of selected parameters of the internal environment.
APA, Harvard, Vancouver, ISO, and other styles
7

Betuz, Naima Ebru. "Assessment Of Indoor Air Quality In Crowded Educational Spaces." Master's thesis, METU, 2013. http://etd.lib.metu.edu.tr/upload/12615317/index.pdf.

Full text
Abstract:
Indoor air quality has become a challenge together with the global aim &lsquo<br>decreasing energy consumption&rsquo<br>. Increasing insulation levels of building envelopes but implementing inaccurate building system details has caused excessive heat, accumulation of pollutants, etc. in spaces. In terms of educational spaces, the increase in complaints and illnesses due to unfavorable indoor air conditions leads to a decrease in concentration and so academic performance of students and staff. In the context, the aim of the study was indicating the poor indoor air quality conditions caused by i
APA, Harvard, Vancouver, ISO, and other styles
8

Israelsson, Simon, and Anton Hallgren. "Ventilation i flerbostadshus- hur fungerar den ur ett fuktperspektiv?" Thesis, Linnéuniversitetet, Institutionen för byggteknik (BY), 2018. http://urn.kb.se/resolve?urn=urn:nbn:se:lnu:diva-76585.

Full text
Abstract:
För att skapa ett bra inomhusklimat i flerbostadshus ställs höga krav på ventilationssystemet för att ta hand om den fukt som skapas. Det finns således anledning att undersöka om Boverkets byggreglers krav för minsta luftflöde är tillräckligt ur fuktsynpunkt. Syftet är att uppmärksamma problem med ökande fukttillskott i nyproducerade flerbostadshus vilket skulle kunna förändra projekteringen av ventilation i framtiden. För att kunna undersöka om Boverkets byggreglers krav är tillräckligt ur fuktsynpunkt analyseras relativ fuktighet och fukttillskott i fyra flerbostadshus i Jönköping. Det framg
APA, Harvard, Vancouver, ISO, and other styles
9

Bučko, Ondrej. "Efektivní řízení technologií budov s důrazem na měření vlhkosti a koncentrace CO2." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2021. http://www.nusl.cz/ntk/nusl-442540.

Full text
Abstract:
The diploma thesis deals with automated measurement of humidity and CO2 concentration inside buildings. Results of this measurement form the input parameters for the effective management of technologies reducing the energy performance of buildings. In the introduction, the issue of indoor air quality of buildings and indicators characterizing this quality are approached. The technical part of the thesis consists of making a measuring device which contains two prototype sensors provided by Teco Inc. with online access to measured data. The measurement of relative humidity, CO2 concentration and
APA, Harvard, Vancouver, ISO, and other styles
10

Chadima, Tomáš. "Analýza vnitřního klimatu lázeňského komplexu." Master's thesis, Vysoké učení technické v Brně. Fakulta stavební, 2019. http://www.nusl.cz/ntk/nusl-392187.

Full text
Abstract:
The thesis deals with the environmental assessment of buildings, concrete objects Letní lázně at Karlova Studánka. The first part describes the issue and legislation. There is also described a method of experimental measurement and methods of moisture measurement. The second part deals with the analysis of the specified object, description of selected renewable sources and description of possible modifications of the object. The third part is devoted to modeling and simulation of the specified object in DesignBuilder. Using the model were created various simulations with various modifications
APA, Harvard, Vancouver, ISO, and other styles
11

Engström, Tobias, and Jesper Johansson. "Projektera och producera en fuktsäker byggnad : En studie som klarlägger ansvarstagandet och hur kommunikationen mellan aktörer kan förbättras." Thesis, Karlstad University, Faculty of Technology and Science, 2007. http://urn.kb.se/resolve?urn=urn:nbn:se:kau:diva-1193.

Full text
Abstract:
<p>Tidigare studier visar att ansvarsfrågan för fuktsäkerheten är oklar samt att kunskapsöverföringen mellan byggprocessens olika aktörer brister. Detta kan leda till bristande fuktsäkerhet som i sin tur kan leda till hälsoproblem för de boende.</p><p>Den 1 juni 2006 kom Boverket ut med en ny regelsamling (BBR) och som numer innehåller tydligare regler och omformulerade krav gällande fuktsäkert byggande.</p><p>Detta arbete syftar till att redovisa risker med informationsspridningen mellan byggprocessens olika skeden samt att redovisa vilka förändringar som måste göras av aktörerna för att uppf
APA, Harvard, Vancouver, ISO, and other styles
12

Hansson, Linus, Andreas Nyberg, and Jonas Wahlberg. "Fuktsäkringsarbete i ett byggprojekt : – En undersökning om hur byggprocessens aktörer arbetar för att uppnå samhällskraven." Thesis, Karlstad University, Division for Engineering Sciences, Physics and Mathematics, 2006. http://urn.kb.se/resolve?urn=urn:nbn:se:kau:diva-176.

Full text
Abstract:
<p>Lagen säger att man inte får uppföra byggnader så att det riskerar människors hälsa. Trots detta uppförs byggnader så att ohälsa uppstår för de boende. Arbetet behandlar hur man i ett byggprojekt arbetar med fuktsäkring. Syftet är att undersöka hur man i projektet arbetar med att fuktsäkra byggnaderna. Målet är att lyfta fram var i processen det finns risker när det gäller fuktsäkring, och även ge förslag till förbättringar av arbetet med fuktsäkringen. En studie över lagar och förordningar har gjorts för att se vilka krav som ställs på en byggnad ur fuktsynpunkt samt hur branschregler till
APA, Harvard, Vancouver, ISO, and other styles
13

Pretlove, Stephen Edward Charles. "Predicting relative humidity in UK dwellings." Thesis, University College London (University of London), 2000. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.555004.

Full text
Abstract:
Mould growth affects a significant proportion of dwellings in the UK and Europe. The house dust mite is also known to inhabit most dwellings and is one of the key factors affecting the health of the occupants. One of the key variables affecting mould growth and house dust mite populations is relative humidity. The relative humidity in a dwelling is dependent upon both the moisture levels and the temperature. The ability to assess the impact of different interventions on the relative humidity depends upon the ability to model both the internal temperature and the internal vapour pressure. This
APA, Harvard, Vancouver, ISO, and other styles
14

Kwiatkowski, jerzy. "Moisture in buildings air-envelope interaction." Lyon, INSA, 2009. http://theses.insa-lyon.fr/publication/2009ISAL0012/these.pdf.

Full text
Abstract:
L'humidité relative de l'air est un des paramètres les plus importants ayant une influence sur le confort, la qualité de l'air intérieur et aussi sur la performance énergétique et la durabilité des enveloppes. Les matériaux qui adsorbent et désorbent l’humidité peuvent être utilisés pour modérer l’amplitude des variations de l’humidité relative et ainsi améliorer le climat intérieur et diminuer les consommations énergétiques. Le transfert de masse dans les matériaux hygroscopiques, même si il est pris dans les simulations dynamiques des bâtiments, il est simplifié. Négliger le transport de vap
APA, Harvard, Vancouver, ISO, and other styles
15

Wang, Xiaotao. "Study of Sensor Network Applications in Building Construction." Thesis, KTH, Reglerteknik, 2013. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-140422.

Full text
Abstract:
This thesis presents a study of wireless sensor networks applied in monitoring the curing process of concrete building structure. To replace the massive user intervention of the traditional monitoring methods with automated data acquisition, various types of sensors are developed for different concrete tests, including compressive strength measurement, maturity test, and relative humidity test. The main purpose of the thesis is to provide an analysis of existing commercial sensors as well as research prototypes, comparing different test methods and communication models. Distribution of sensors
APA, Harvard, Vancouver, ISO, and other styles
16

af, Klintberg Tord. "Air Gap Method : Air-Gaps in Building Construction to avoid Dampness & Mould." Doctoral thesis, KTH, Byggnadsteknik, 2012. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-102873.

Full text
APA, Harvard, Vancouver, ISO, and other styles
17

Pommer, Linda. "Oxidation of terpenes in indoor environments : A study of influencing factors." Doctoral thesis, Umeå University, Ecology and Environmental Science, 2003. http://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-29.

Full text
Abstract:
<p>In this thesis the oxidation of monoterpenes by O3 and NO2 and factors that influenced the oxidation were studied. In the environment both ozone (O3) and nitrogen dioxide (NO2) are present as oxidising gases, which causes sampling artefacts when using Tenax TA as an adsorbent to sample organic compounds in the air. A scrubber was developed to remove O3 and NO2 prior to the sampling tube, and artefacts during sampling were minimised when using the scrubber. The main organic compounds sampled in this thesis were two monoterpenes, alfa-pinene and delta-3-carene, due to their presence in both i
APA, Harvard, Vancouver, ISO, and other styles
18

Nalbone, Joseph Torey. "Evaluation of building and occupant response to temperature and humidity: non-traditional heat stress considerations A comparison of different construction types used by the Texas Department of Criminal Justice." Texas A&M University, 2004. http://hdl.handle.net/1969.1/1504.

Full text
Abstract:
This study examined the effects of construction types on the indoor environment of selected prison facilities in the State of Texas. Three collocated facilities of the Texas Department of Criminal Justice were monitored for temperature, relative humidity and barometric pressure over a period of fifteen months. The objectives of the study were to examine the response of the built environment to the stressors of ambient conditions, characterize the influence of the construction method for each facility and study the responses of the occupants of the buildings. From the data, an apparent temperat
APA, Harvard, Vancouver, ISO, and other styles
19

Uherka, Pavel. "Tepelně-vlhkostní analýza konstrukcí masivních dřevostaveb." Master's thesis, Vysoké učení technické v Brně. Fakulta stavební, 2016. http://www.nusl.cz/ntk/nusl-240341.

Full text
Abstract:
This thesis deals with massive wooden buildings especially with regard to the current approach to their design, assessment and approval. In this thesis are shown future possibilities of development of traditional wooden buildings with regard to current thermal technical requirements. Theoretical considerations are then compared with measurements which were performed on massive wooden wall samples.
APA, Harvard, Vancouver, ISO, and other styles
20

Rudblad, Stig. "Nasal mucosal reactivity after long-time exposure to building dampness /." Stockholm, 2004. http://diss.kib.ki.se/2004/91-974455-5-X/.

Full text
APA, Harvard, Vancouver, ISO, and other styles
21

Fikejsl, Tomáš. "Technická zařízení budov v budovách s téměř nulovou spotřebou." Master's thesis, Vysoké učení technické v Brně. Fakulta stavební, 2017. http://www.nusl.cz/ntk/nusl-265497.

Full text
Abstract:
The thesis deals with the issue will be nearly zero energy. The theoretical part is divided into several chapters. Describes the requirements of applicable legislation of the Czech Republic and the EU and the application of renewable energy in these buildings. The third and last part serves as a basis for part of the experiment. Calculation section applies theoretical knowledge into practice. The subject has become a new residential building in which they are designed to ensure the technical equipment required internal environment. The proposal concerns the heating, ventilation, cooling, domes
APA, Harvard, Vancouver, ISO, and other styles
22

Nogová, Tereza. "Hodnocení metod pro stanovení vlhkosti ve stavebních konstrukcích." Master's thesis, Vysoké učení technické v Brně. Fakulta stavební, 2015. http://www.nusl.cz/ntk/nusl-227695.

Full text
Abstract:
This thesis compares the methods for the determination of air and moisture condensation in the construction. There are descriptions of the various methods and formulas for measuring humidity and methods for the calculation of condensation in building structures. The practical part describes the development of a method for verifying the condensation of moisture in construction. Parts of this work are the materials and methods for the development of the humidity sensor. There were used two methods – capacitive and resistive for measuring moisture condensation. In the conclusion is the evaluation
APA, Harvard, Vancouver, ISO, and other styles
23

Rouchier, Simon. "Hygorthermal performance assessment of damaged building materials." Phd thesis, Université Claude Bernard - Lyon I, 2012. http://tel.archives-ouvertes.fr/tel-00980172.

Full text
Abstract:
An importantmatter in the field of building physics is the questioning of how wellbuildings sustain ageing, and how their overall efficiency evolves over their lifetime.Many causes for degradation are carried by moisture transfer through these porousmaterials. Indeed, infiltratedwatermay transport chemicals, altermechanical properties,and cause freeze thaw damage or mould development. It may also affect thermalproperties and energetic efficiency, as well as the health and comfort of the occupants.The understanding of how moisture transfer properties evolve during the lifespan ofbuildingmateria
APA, Harvard, Vancouver, ISO, and other styles
24

Sjödin, Johan. "Steel-to-timber dowel joints : Influence of moisture induced stresses." Licentiate thesis, Växjö University, School of Technology and Design, 2006. http://urn.kb.se/resolve?urn=urn:nbn:se:vxu:diva-1286.

Full text
Abstract:
<p>Joints are critical parts of timber structures, transmitting static and dynamic forces between structural members. The ultimate behavior of a loaded building depends strongly on the structural configuration and the capacity of the joints. The collapse of a whole building or less extensive accidents that may occur is usually starting as a local failure inside or in the vicinity of a joint. Such serious failures have recently occurred in our Nordic countries. Especially the collapse of two large glued laminated timber structures clearly indicates the need of an improved joint design. The tren
APA, Harvard, Vancouver, ISO, and other styles
25

Burešová, Eliška. "Analýza metod měření vlhkosti ve stavebních materiálech." Master's thesis, Vysoké učení technické v Brně. Fakulta stavební, 2021. http://www.nusl.cz/ntk/nusl-433576.

Full text
Abstract:
The diploma thesis is focused on the issue of measuring the moisture content in building materials using indirect methods that allow its long-term measurement. The theoretical part of the thesis provides an overview of the forms of moisture in porous building materials and provide an overview of the principles of measuring moisture content. In the experimental part of the thesis, the aim is to verify the available methods for long-term monitoring of moisture in building materials built into building structures. Proven methods of measuring humidity include resistance, capacitive and microwave m
APA, Harvard, Vancouver, ISO, and other styles
26

Ekstrand-Tobin, Annika. "Hälsopåverkan av åtgärder i fuktiga byggnader /." Linköping : Univ, 2003. http://www.bibl.liu.se/liupubl/disp/disp2003/tek859s.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
27

Cavallius, Matilda, and Oskar Rehnstedt. "Befuktning : Installationer, processer och hälsofördelar." Thesis, KTH, Byggteknik och design, 2017. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-215298.

Full text
Abstract:
Det finns tydliga hälsofördelar med en relativ fuktighet på 40–60% inomhus. Trots detta finns det idag inga direktiv på hur man ska styra den relativa fuktigheten inomhus. Många gånger diskuteras det kring avfuktning men i denna rapport tas befuktning upp ur ett hälsoperspektiv.I denna studie har det undersökts huruvida befuktningssystem skulle kunna användas i större utsträckning till fördel för människors hälsa.I rapporten redogörs för olika befuktningmetoder samt deras termofysiska processer - adiabatisk eller isotermisk. Dessutom undersöks vad som händer med energin i luften och vattenånga
APA, Harvard, Vancouver, ISO, and other styles
28

Bendouma, Mathieu. "Systèmes d’isolation thermique par l’extérieur : études expérimentales et numériques des transferts de chaleur et d’humidité." Thesis, Lorient, 2018. http://www.theses.fr/2018LORIS485/document.

Full text
Abstract:
L’isolation thermique par l’extérieure (ITE) constitue une solution technique intéressante pour améliorer les performances énergétiques du secteur du bâtiment. Cependant, l’ITE peut venir modifier l’équilibre hygrothermique de l’enveloppe et affecter sa durabilité, notamment au regard de l’humidité. Dans ce contexte, un premier travail a consisté à étudier en laboratoire le comportement hygrothermique de trois systèmes d’ITE rapportés sur une paroi en parpaing : un système ETICS (PSE sous enduit mis en œuvre par voie humide) et deux systèmes sous bardage (mis en œuvre par voie sèche), dont un
APA, Harvard, Vancouver, ISO, and other styles
29

Belleudy, Clément. "Modélisation des transferts d’air et leur impact sur le comportement hygrothermique de l'enveloppe des bâtiments." Thesis, Université Grenoble Alpes (ComUE), 2016. http://www.theses.fr/2016GREA0002/document.

Full text
Abstract:
Dans un contexte de durcissement des règlementations thermiques, la maîtrise de l'étanchéité à l'air des bâtiments est essentielle pour atteindre les objectifs de consommation énergétique. Les fuites d'air parasites à travers l'enveloppe, dues aux défauts de conception ou à une mauvaise mise en oeuvre, mènent à une surconsommation énergétique, mais aussi à des pathologies liées à l'humidité, mettant en péril la durabilité du bâti et la santé des occupants. Le risque lié à l'humidité est particulièrement présent dans les cas des enveloppes légères à ossature bois, sensibles aux transferts d'air
APA, Harvard, Vancouver, ISO, and other styles
30

Bravenec, David. "Diagnostika a návrh eliminace tepelných mostů budov." Master's thesis, Vysoké učení technické v Brně. Fakulta stavební, 2017. http://www.nusl.cz/ntk/nusl-265536.

Full text
Abstract:
This thesis presents a comparison of building materials for vertical bearing structures of buildings, thermal insulation materials and mutual combination of structural materials and insulators. Furthermore, there are possibilities for solving the most common insulation thermal bridges construction. The paper evaluated the pros and cons of different combinations of building materials. Teplo and Area programs were used for the calculations.
APA, Harvard, Vancouver, ISO, and other styles
31

Mandrara, Zaratiana. "Impact thermique des revêtements en bois sur l’ambiance intérieure des bâtiments : application dans l’habitat traditionnel en France et à Madagascar." Thesis, Lyon, INSA, 2011. http://www.theses.fr/2011ISAL0052/document.

Full text
Abstract:
Les constructions traditionnelles en bois en France et à Madagascar témoignent de l’utilisation ancienne d’abondantes ressources forestières locales. Le bois peut être considéré comme un matériau naturel et renouvelable dans la mesure où les ressources forestières sont gérées durablement. L’utilisation du bois dans la construction contribue largement à la maîtrise du cycle du carbone atmosphérique et à la limitation des émissions de gaz à effet de serre. Ce travail présente les principales caractéristiques physiques du matériau bois et des systèmes constructifs associés, montrant l’importance
APA, Harvard, Vancouver, ISO, and other styles
32

Wu, Dongxia. "Experimental and numerical study on passive building envelope integrated by PCM and bio-based concrete." Electronic Thesis or Diss., Université de Lorraine, 2022. http://www.theses.fr/2022LORR0104.

Full text
Abstract:
Les économies d'énergie et la réduction des émissions des gaz à effet de serre dans le secteur du bâtiments ainsi que le maintien d’un confort hygrométrique prennent une importance majeur ces dernières décennies. L'utilisation de matériaux à changement de phase (MCP) ou de matériaux hygroscopiques d'origine végétale pour l'enveloppe des bâtiments est une solution prometteuse. Les MCP conduit à améliorer le confort thermique intérieur et à réduire la consommation d'énergie, tandis que les matériaux hygroscopiques biosourcés sont des matériaux respectueux de l'environnement et permettent la régu
APA, Harvard, Vancouver, ISO, and other styles
33

Sjödin, Johan. "Strength and Moisture Aspects of Steel Timber Dowel Joints in Glulam Structures : An Experimental and Numerical Study." Doctoral thesis, Växjö universitet, Institutionen för teknik och design, 2008. http://urn.kb.se/resolve?urn=urn:nbn:se:vxu:diva-2002.

Full text
Abstract:
Joints are critical parts of timber structures, transmitting static and dynamic forces between structural members. The ultimate behavior of e.g. a building depends strongly on the structural configuration and the capacity of its joints. The complete collapse of a building or other less extensive accidents that may occur usually start as a local failure inside or in the vicinity of a joint. Such serious failures have recently occurred in the Nordic countries. Especially the collapses of two large glued-laminated timber (glulam) structures clearly indicate the need of an improved joint design. T
APA, Harvard, Vancouver, ISO, and other styles
34

Berger, Julien. "Contribution à la modélisation hygrothermique des bâtiments : application des méthodes de réduction de modèle." Thesis, Grenoble, 2014. http://www.theses.fr/2014GRENA028/document.

Full text
Abstract:
Les bâtiments existants reposent sur un équilibre stable qui assure leur durabilité. Toute exécution de travaux de réhabilitation qui déplace cet équilibre peut être à l'origine de désordres. En ce sens, les travaux peuvent être qualifiés de pathogènes. Dans le cadre de rénovations énergétiques, la problématique de l'humidité dans les bâtiments existants nécessite donc une attention particulière. Il convient donc de fournir aux acteurs de la construction des modèles de simulation du comportement hygrothemique global des bâtiments et d'évaluer les risques de pathologies liées à l'humidité. L'él
APA, Harvard, Vancouver, ISO, and other styles
35

Лазаренко, С. М. "Програмно-апаратна реалізація припливно витяжної установки й управління елементами вентиляції як частина системи «розумного дому»". Thesis, Чернігів, 2021. http://ir.stu.cn.ua/123456789/22992.

Full text
Abstract:
Лазаренко, С. М. Програмно-апаратна реалізація припливно витяжної установки й управління елементами вентиляції як частина системи «розумного дому» : дипломна робота : 123 - Комп’ютерна інженерія / С. М. Лазаренко ; керівник роботи Є. В. Риндич ; НУ "Чернігівська політехніка", кафедра Інформаційних та комп’ютерних систем. - Чернігів, 2021. - 98 с.<br>Роботу присвячено розгляду і розробці системи припливно-витяжної вентиляції з рекуперацією тепла і вологи у приватному будинку як частини системи «розумного дому». Створено класифікації функціональних і структурних особливостей систем «розум
APA, Harvard, Vancouver, ISO, and other styles
36

Taouirte, Yousra. "Etude des mοyens innοvants d'améliοratiοn des perfοrmances énergétique dans le bâtiment : expérimentatiοn et mοdélisatiοn". Electronic Thesis or Diss., Normandie, 2025. http://www.theses.fr/2025NORMC205.

Full text
Abstract:
La transition vers une construction durable et écoénergétique est un enjeu clé dans la lutte contre le changement climatique et la réduction de l’empreinte carbone du secteur du bâtiment. Pour répondre à ces défis, l’utilisation de matériaux biosourcés représente une alternative prometteuse en raison de leur faible impact environnemental et de leurs propriétés naturelles de régulation thermique et hygrométrique. Cependant, ces matériaux présentent encore des limites en matière de performance énergétique et de stabilité hygrothermique, nécessitant une optimisation pour leur intégration à grande
APA, Harvard, Vancouver, ISO, and other styles
37

Gonçalves, Gonçalo Machado Monteiro Ferreira. "Influence of materials’ hygroscopicity in the control of relative humidity and temperature of old buildings." Master's thesis, 2017. http://hdl.handle.net/10362/30795.

Full text
Abstract:
The comfort of buildings indoor environment and materials durability are severally affected by peaks of temperature and relative humidity (RH) in interior of buildings and therefore they should be controlled and damped. The presence of people inside buildings as well as artificial illumination and all kind of equipment cause a releasing of moisture to environment, which originates an increment of its relative humidity. The occupants, artificial illumination and equipment also originate a temperature raising depending the occupants’ activity and the quantity and power of illumination and equip
APA, Harvard, Vancouver, ISO, and other styles
38

Csiszar, Joseph. "Analysis of the economic aspects of insulation in buildings with special reference to the stresses in framed structures, resulting from changes in temperature and humidity." Thesis, 2015. http://hdl.handle.net/10539/17013.

Full text
Abstract:
The consideration of the problems of economic insulation against temperature variation has only come to the fore in recent years* The outstanding developments in methods of central heating which have grown up with the XXth Century have brought with them a desire to investigate the manner in vAiich heat losses occur in different types of buildings. After the Great War, shortage of capital, lack of fuel, and the general want of suitable material for building oaused a demand for general construction on much cheaper lines and vith the use of much lighter material* One difficulty of this
APA, Harvard, Vancouver, ISO, and other styles
39

Carvalho, Sara Raquel Loureiro dos Santos. "Humidade em edifícios antigos : reabilitação do edifício do Governo Civil do Porto para instalação de um Hotel de 4 estrelas." Master's thesis, 2015. http://hdl.handle.net/10437/6993.

Full text
Abstract:
Orientação: João Carlos Santos<br>Esta dissertação tem como objetivo analisar as anomalias provocadas pela humidade nos edifícios antigos e as suas soluções de reparação, focando-se no caso do estudo do edifício do Governo Civil do Porto, na Rua Augusto Rosa. Os edifícios antigos são caracterizados pelas suas técnicas de construção e pelos materiais utilizados na sua conceção que, com o decorrer do tempo, desenvolvem anomalias que necessitam ser combatidas eficazmente para evitar a sua propagação, sendo a humidade o agente de deterioração que mais danos causa. Numa primeira parte, é realizad
APA, Harvard, Vancouver, ISO, and other styles
40

Montanaro, Umberto. "Building Indoor Air Temperature and Humidity Control via Innovative Techniques." Tesi di dottorato, 2016. http://www.fedoa.unina.it/10681/1/PhD_Thesis_Montanaro.pdf.

Full text
Abstract:
In this thesis a novel Model Reference Adaptive Control approach, developed to tame the thermohygrometric behaviour of buildings and to guarantee the indoor comfort, is presented. The main advantages of the proposed method are: i) robustness with respect to a large class of perturbations, external disturbances, nonlinear unmodelled dynamics or parameters uncertainty; ii) ability to impose some given profiles to the thermohygrometric variables, iii) accurate regulation and fast tracking of indoor air temperature and humidity in the case of stringent requirements in special building spaces. In o
APA, Harvard, Vancouver, ISO, and other styles
41

CHANG, WEN-TE, and 張文德. "The Development of Building Physiology Information System - Monitoring in Temperature and Humidity." Thesis, 2009. http://ndltd.ncl.edu.tw/handle/64156845523777890383.

Full text
Abstract:
碩士<br>逢甲大學<br>土木及水利工程所<br>97<br>Physical signs can be used to diagnose health in a human body and from the standpoint of building medicine, the physical signs of a building (temperature, humidity, stress, strain) can have the same importance when it comes to building health management. Ways to measure the internal temperature and humidity of concrete structures (e.g. using thermal couple and optical fiber) include commonly used embedding or wiring methods, but in application the cost is high and radio frequency and wiring are difficult to maintain. This study uses low cost Radio Frequency Inte
APA, Harvard, Vancouver, ISO, and other styles
42

Joshi, Shailesh Narayan. "Performance evaluation of duct-mounted relative humidity sensors used in building HVAC applications /." 2005.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
43

Juang, Gwo-Jyh, and 莊國誌. "A Study on Humidity Diagnosis and Improvement Methods of Building Material in Taiwan." Thesis, 2010. http://ndltd.ncl.edu.tw/handle/r3ztv7.

Full text
Abstract:
碩士<br>國立臺北科技大學<br>建築與都市設計研究所<br>98<br>The hot and damp climate of Taiwan suits the environment which the mold grows, drifts in particular in the air mold spore or the metabolite, easy to become humanity&apos;&apos;s anaphylactogen, initiates asthma, anaphylaxis and measles, allergic rhinitis, conjunctivitis, gastroenteritis and dermatitis. In recent years many people use humidifiers at home that easily causes the home to be poorly ventilated, usually with the humidity maintained above 70% which is extremely easy to encourage mold reproduction. Besides the control room in humidity, the most eff
APA, Harvard, Vancouver, ISO, and other styles
44

Ching-I, Chen, and 陳靜怡. "Analysis of Model of Emision of VOCs for Temperature and Humidity from Building Materials." Thesis, 2001. http://ndltd.ncl.edu.tw/handle/25097969907197965687.

Full text
Abstract:
碩士<br>中國文化大學<br>材料科學與製造研究所<br>89<br>The volatile organic compounds (VOCs) from indoor materials and products are the major sources of indoor air pollution, and the emissions can resulted in health or comfort problems and drop the indoor air quality(IAQ). Those indoor materials and products include furniture, decoration, wallpaper, tapestry, carpet, ceiling, coating materials, binder, solvents and addivities. Refer to the standard methods of U.S. ASTM D-5116-90, we set up a small environmental test system. The small environmental test system was used to develop the emissions characte
APA, Harvard, Vancouver, ISO, and other styles
45

Chen, Chang-Yuan, and 陳昶源. "The Conditioning Effect of Compisite Walls and Roofs on The Thermal Insulation ,Temperature and Relative Humidity of Wooden Structure Building." Thesis, 2000. http://ndltd.ncl.edu.tw/handle/09769442179428068496.

Full text
Abstract:
碩士<br>國立臺灣大學<br>森林學研究所<br>88<br>The thermal effects of wood structural building wall and roof with thermal insulation material were investigated in this study. The experimental results are summarized as follows: The wooden structure building wall with solid wood and cement board materials were tested, the heat flow of wall materials decreased with increasing thickness, and the thermal resistance and overall thermal resistance of wall materials increased with increasing thickness. The thermal conductivity of wooden structure building wall and roof was <0.02(W/m‧k). And It’s lower tha
APA, Harvard, Vancouver, ISO, and other styles
46

Ali, S. M., B. Khan, Geev Mokryani, C. A. Mehmood, M. Jawad, and U. Farid. "Environment driven consumer EC model incorporating complexities of consumer body dynamics." 2019. http://hdl.handle.net/10454/17106.

Full text
Abstract:
Yes<br>Energy consumption (EC) of consumers primarily depends on comfort level (CL) affirmed by brain sensations of the central nervous system. Environmental parameters such as surroundings, relative humidity, air temperature, solar irradiance, air pressure, and cloud cover directly influence consumer body temperature that in return affect blood dynamics perturbing brain comfort sensations. This CL (either in summer, winter, autumn, or spring season) is a function of external environment and internal body variations that force a consumer toward EC. To develop a new concept of consumer's EC, fi
APA, Harvard, Vancouver, ISO, and other styles
47

Huang, Chi-Bin, and 黃啟賓. "A Study on the Sintering of High Performance Humidity Control Ceramic of Green Building Material by MSWI Boiler Ash, Palygorskite and Waste Glass." Thesis, 2015. http://ndltd.ncl.edu.tw/handle/70076661910234247234.

Full text
Abstract:
碩士<br>淡江大學<br>水資源及環境工程學系碩士班<br>103<br>Municipal solid waste incinerator (MSWI) will produce fly ash which contains a large amount of heavy metals and the leaching concentration usually doesn’t meet the regulatory limits of EPA. Therefore, the fly ash is considered to be hazardous waste. Fly ash divided into reaction ash and boiler ash. Many studies have found that the reaction ash always contains large amount of alkalinity and heavy metals. However, sintering process will decompose the components and it will also generate lots of gas that like the foaming characteristics. Leaching concentratio
APA, Harvard, Vancouver, ISO, and other styles
48

Yi, Lin Fang, and 林芳毅. "A study of traditional quadrangle building and variation of indoor temperature and relative humidity of Lin’s Ancient compound at Nan-zi District , Kaohsiung City." Thesis, 2004. http://ndltd.ncl.edu.tw/handle/70934267104655800341.

Full text
Abstract:
碩士<br>樹德科技大學<br>建築與古蹟維護研究所<br>91<br>The studies of Taiwan traditional architect have drawn much attention to temples and large official buildings instead of civil architecture that can better reflect local history and the reality of ordinary people life. Lin Ancient House locates at Nan-tzi, Kaohsiung City. The house was built 112 years ago and a famous building in the area where the residents worked as farmers at that time. This article aims to explore the historical meaning in terms of architecture and produce detailed measurements regarding the physical aspects of the house. Using the ce
APA, Harvard, Vancouver, ISO, and other styles
49

Chang, Wen-Hsuan, and 張文軒. "Humidity Control Characteristics and Capacity of Porous Building Material Produced from LED Waste Quartz Sand and CRT Waste Glass Addition Waste Catalyst by Sintering." Thesis, 2015. http://ndltd.ncl.edu.tw/handle/42772730150338617328.

Full text
Abstract:
碩士<br>國立宜蘭大學<br>環境工程學系碩士班<br>103<br>This study fabricates humidity control porous ceramics the following operating conditions: a compaction pressure (5MPa), sintering temperature of 600–750°C, sintering time of 5 minutes, temperature increase rate of 5°C/min, and a percentage of light emitting doide (LED) waste quartz sand, cathode ray tube (CRT) waste panel glass, CRT waste funnel glass in waste catalyst of 0–40%. The heat-treated samples were identified using X-ray diffraction (XRD), Fourier transmission infrared spectroscopy (FTIR), scanning electron microscopy (SEM). The equilibrium moistu
APA, Harvard, Vancouver, ISO, and other styles
50

STUDENÁ, Sandra. "Zhodnocení stávajícího stavu stavby kravína v Zubčicích z hlediska mikroklimatických a stavebně technických podmínek." Master's thesis, 2016. http://www.nusl.cz/ntk/nusl-253179.

Full text
Abstract:
The thesis deals with the specific agricultural buildings for housing and breeding of dairy cows in terms of civil engineering and microclimatic conditions. The theoretical part describes the requirements for microclimate in stables, general and legislative requirements for indoor environmental quality, methods and tools for measuring microclimate, materials and construction of stable objects for cattle breeding. The second (practical) part of the thesis shows the research of selected buildings. This part examines the internal microclimate of the stables and technical condition of the building
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!