Academic literature on the topic 'ICP mass spectrometer'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'ICP mass spectrometer.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "ICP mass spectrometer"

1

Labusov, V. A., A. A. Dzyuba, V. G. Garanin, et al. "Optical spectrometers Grand: a new tool for measuring mass fractions of analytes." Аналитика и контроль 28, no. 3 (2024): 259–69. https://doi.org/10.15826/analitika.2024.28.3.004.

Full text
Abstract:
In 2023, optical spectrometers Grand were included in the Russian State Register of Measuring Instruments under No. 89108-23 as a tool for measuring the mass fractions of analytes in natural and industrial materials. These spectrometers are manufactured by VMK-Optoelektronika company in ten modifications, nine of which are atomic emission spectrometers and one is an atomic absorption spectrometer: Atomic emission spectrometers a. Grand-Globula, Grand-Kristall, and Grand-Express arc and spark discharge spectrometers for direct (without preliminary chemical preparation) analysis of powder sample
APA, Harvard, Vancouver, ISO, and other styles
2

Baranovskaya, Natalia V., Svetlana I. Mazukhina, Alexander M. Panichev, et al. "Features of chemical elements migration in natural waters and their deposition in the form of neocrystallisations in living organisms (physico-chemical modeling with animal testing)." Bulletin of the Tomsk Polytechnic University Geo Assets Engineering 335, no. 2 (2024): 187–201. http://dx.doi.org/10.18799/24131830/2024/2/4459.

Full text
Abstract:
Relevance. An original modeling method is presented, which allows obtaining qualitatively new results in practice of ecological-geochemical and biomedical research. Aim. To obtain new data on the forms of element migration in the conditions of animal and human organism parameters by means of physicochemical modeling (PC "Selector") with verification of calculated data with the results obtained for real natural objects and animal organisms. Objects. Samples of natural waters and tissues of wild animals. Methods. Computer modeling (PC "Selector"); inductively coupled plasma mass spectrometry (IC
APA, Harvard, Vancouver, ISO, and other styles
3

Nikolaeva, I. V., A. A. Kravchenko, S. V. Palessky, S. V. Nechepurenko, and D. V. Semenova. "ICP-MS AND ICP-AES ANALYSIS OF PLANT REFERENCE MATERIALS." Industrial laboratory. Diagnostics of materials 85, no. 6 (2019): 11–24. http://dx.doi.org/10.26896/1028-6861-2019-85-6-11-24.

Full text
Abstract:
Two methods — ICP-MS and ICP-AES are used for certification of the new reference material — needles of Siberian pine (NSP-1). Techniques of the analysis include decomposition of plant samples in two different ways: acid digestion in a microwave system MARS-5 and lithium metaborate fusion followed by ICP-MS and ICP-AES analysis of the solutions. Simultaneous determinations of all the elements were carried out in low, medium and high resolution using SF-mass-spectrometer ELEMENT and atomic-emission spectrometer IRIS Advantage with external calibrations and internal standards (In — ICP-MS, Sc —IC
APA, Harvard, Vancouver, ISO, and other styles
4

Makarov, V. A., and T. K. Savosteenko. "Determination of the mass fraction of potassium and sodium oxides in the dust of electric furnace filters by atomic emission spectrometry with inductively coupled plasma." Litiyo i Metallurgiya (FOUNDRY PRODUCTION AND METALLURGY), no. 3 (October 20, 2020): 62–66. http://dx.doi.org/10.21122/1683-6065-2020-3-62-66.

Full text
Abstract:
A method of measuring the mass fraction of potassium and sodium oxides in the dust filters of electric arc furnaces by atomic emission spectrometry with the inductively coupled plasma (AES-ICP) was developed. Possibilities of atomic emission spectrometers of iCAP series for determination of potassium and sodium in dust of filters of electric arc furnaces are investigated.A method for converting potassium and sodium oxides into solution is proposed. Calibration of the spectrometer was carried out on aqueous solutions with a known concentration of potassium and sodium. For the preparation of cal
APA, Harvard, Vancouver, ISO, and other styles
5

Makarov, V. A., and T. K. Savosteenko. "Determination of phosphorus mass fraction in steels of plasma atomic emission spectrometry." Litiyo i Metallurgiya (FOUNDRY PRODUCTION AND METALLURGY), no. 1 (March 26, 2021): 86–90. http://dx.doi.org/10.21122/1683-6065-2021-1-86-90.

Full text
Abstract:
A method for measuring the mass fraction of phosphorus in steels by atomic emission spectrometry with the inductively coupled plasma (AES-ICP) has been developed. Possibilities of atomic emission spectrometers of iCAP series for determination of phosphorus in steels allowing to reduce considerably duration of the analysis and to increase its profitability in comparison with chemical methods of the analysis are investigated. A method of decomposition of steel for the complete transfer of phosphorus into solution is proposed. The possibility of software spectrometers “iTeva” in the analysis by t
APA, Harvard, Vancouver, ISO, and other styles
6

KAWAGUCHI, Hiroshi, Tomokazu TANAKA, Tetsunari NAKAMURA, and Atsushi MIZUIKE. "Construction of ICP/mass spectrometer and its characteristics." Bunseki kagaku 36, no. 4 (1987): 271–75. http://dx.doi.org/10.2116/bunsekikagaku.36.4_271.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Hieftje, Gary M., James H. Barnes, Ole A. Grøn, et al. "Evolution and revolution in instrumentation for plasma-source mass spectrometry." Pure and Applied Chemistry 73, no. 10 (2001): 1579–88. http://dx.doi.org/10.1351/pac200173101579.

Full text
Abstract:
Plasma-source mass spectrometry, usually in the form of inductively coupled plasma mass spectrometry (ICP-MS), has matured into a widely accepted method for ultra-trace multielemental analysis. However, the method exhibits shortcomings. For example, it does not provide adequate precision for isotope ratio measurements if many isotopes are to be determined. Moreover, isobaric overlaps (spectral interferences) can be very troublesome in some situations. Similarly, matrix interferences can adversely affect many determinations. Yet, it is in the area of high-speed transient measurements that ICP-M
APA, Harvard, Vancouver, ISO, and other styles
8

Yamashita, Shuji, Kota Yamamoto, Hiroaki Takahashi, and Takafumi Hirata. "Size and isotopic ratio measurements of individual nanoparticles by a continuous ion-monitoring method using Faraday detectors equipped on a multi-collector-ICP-mass spectrometer." Journal of Analytical Atomic Spectrometry 37, no. 1 (2022): 178–84. http://dx.doi.org/10.1039/d1ja00312g.

Full text
Abstract:
We investigated the capability of high-gain Faraday detectors equipped on a multi-collector-ICP-mass spectrometer (MFC-ICP-MS) in performing both particle size and Ag isotopic ratio determination for individual silver nanoparticles (Ag NPs).
APA, Harvard, Vancouver, ISO, and other styles
9

Logunov, Alexander, Andrey Vorotyntsev, Igor Prokhorov, et al. "Plasma–Chemical Low-Temperature Reduction of Aluminum with Methane Activated in Microwave Plasma Discharge." Metals 15, no. 5 (2025): 514. https://doi.org/10.3390/met15050514.

Full text
Abstract:
High-purity aluminum is widely used in metallurgy, microelectronics and chemical synthesis. In this work, the method of carbothermic reduction of aluminum powder in a microwave plasma discharge with the formation of valuable organic products such as synthesis gas, acetylene and benzene was used. Al powder was studied by inductively coupled plasma mass spectrometry (ICP-MS), scanning electron microscopy (SEM) and powder X-ray diffraction (XRD). The yield of by-products was studied by gas chromatography equipped with a mass spectrometer, as well as optical emission spectroscopy of plasma dischar
APA, Harvard, Vancouver, ISO, and other styles
10

Nielsen, Sune G., Jeremy D. Owens, and Tristan J. Horner. "Analysis of high-precision vanadium isotope ratios by medium resolution MC-ICP-MS." Journal of Analytical Atomic Spectrometry 31, no. 2 (2016): 531–36. http://dx.doi.org/10.1039/c5ja00397k.

Full text
Abstract:
We present and verify a new method to measure vanadium isotope ratios using a Thermo Scientific Neptune multi-collector inductively-coupled plasma mass spectrometer (MC-ICP-MS) operated in medium mass resolution mode.
APA, Harvard, Vancouver, ISO, and other styles
More sources

Dissertations / Theses on the topic "ICP mass spectrometer"

1

Ma, Haibin. "Ion Transport Behaviors Upstream and Downstream from the Sampling Cone of an Inductively Coupled Plasma Mass Spectrometer." BYU ScholarsArchive, 2009. https://scholarsarchive.byu.edu/etd/2196.

Full text
Abstract:
Inductively coupled plasma - mass spectrometry (ICP-MS) is the technique of choice worldwide for trace elemental determinations because of its excellent ionization ability, low detection limits and fast analysis speeds. However, the ICP-MS still suffers from some disadvantages, such as spectral overlap and severe matrix effects. Matrix effects or interferences, partly arise from changes in the analyte transmission through the interfacial region between the ICP and mass spectrometer with changes in sample matrix. Better understanding of the transmission behaviors of analyte through the sampling
APA, Harvard, Vancouver, ISO, and other styles
2

Macedone, Jeffrey Harris. "Ion Transmission in the first vacuum stage of an Inductively Coupled Plasma Mass Spectrometer." BYU ScholarsArchive, 2005. https://scholarsarchive.byu.edu/etd/274.

Full text
Abstract:
The inductively coupled plasma mass spectrometer (ICP-MS) is the instrument of choice for trace and ultra-trace elemental analysis. However, the ICP-MS suffers from matrix effects. Matrix effects occur when instrument response varies as the composition of the sample matrix is changed. Matrix effects, or non-spectroscopic interferences, limit the accuracy of routine analysis. Identification of the sources of matrix effects provide a basis for reducing or eliminating them. As inaccuracies in the ICP-MS are more severe than those in the ICP atomic emission spectrometer, the problem may be due, at
APA, Harvard, Vancouver, ISO, and other styles
3

Edmund, Alisa Jane. "Laser-Induced Fluorescence Imaging of Calcium and Barium Ion Beams in the Second Vacuum Stage of a Commercial Inductively Coupled Plasma Mass Spectrometer." BYU ScholarsArchive, 2014. https://scholarsarchive.byu.edu/etd/4135.

Full text
Abstract:
Inductively coupled plasma-mass spectrometers (ICP-MS) have become the workhorses of many analytical labs over the past few decades. Despite the instruments' high sensitivities and low detection limits there is still a demand for improvements in several aspects of their performance. One area of improvement is in the understanding of "space charge effects" Space charge effects are classified as problems associated with the ion beam. Problems are created when the mutual repulsions of the ions make consistent focusing of the ion beam difficult. This is particularly problematic with samples conta
APA, Harvard, Vancouver, ISO, and other styles
4

Somers, William R. "Testing Direct Simulation Monte Carlo Methods Against the Fluid Equations in the Inductively Coupled Plasma Mass Spectrometer." Diss., CLICK HERE for online access, 2008. http://contentdm.lib.byu.edu/ETD/image/etd2621.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Fields, Robert Eugene 1958. "Application of a quadrupole ion trap mass spectrometer to ICP-MS and the direct detection of x-rays using a charge-injection device." Diss., The University of Arizona, 1997. http://hdl.handle.net/10150/282314.

Full text
Abstract:
This work describes the construction of an inductively-coupled plasma tandem quadrupole mass spectrometer where a quadrupole ion storage trap acts as a second sector and collision cell to achieve neutralization or collisional dissociation of interfering species before mass analysis. Because most elements exist as singly-charged ions in an inductively-coupled plasma (ICP) plume, the ICP can be used as an ionization source for mass analysis (ICP/MS). By reducing the sample to elemental ions before mass analysis, ICP/MS spectra tend to be simple compared with those obtained by ICP-optical emissio
APA, Harvard, Vancouver, ISO, and other styles
6

Radicic, William Neil. "Velocity and Temperature Characterization of the First Vacuum Stage Expansion in an Inductively Coupled Plasma - Mass Spectrometer." Diss., CLICK HERE for online access, 2004. http://contentdm.lib.byu.edu/ETD/image/etd435.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Wu, Shitou [Verfasser], Gerhard [Akademischer Betreuer] [Gutachter] Wörner, and Klaus [Gutachter] Simon. "Laser Ablation-Inductively Coupled Plasma-Mass Spectrometer (LA-ICP-MS) in Geosciences: Further Improvement for Elemental Analysis / Shitou Wu ; Gutachter: Gerhard Wörner, Klaus Simon ; Betreuer: Gerhard Wörner." Göttingen : Niedersächsische Staats- und Universitätsbibliothek Göttingen, 2017. http://d-nb.info/113991121X/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Lofthouse, Simon D. "Sample introduction into inductively coupled plasma mass spectrometry." Thesis, University of Hull, 1999. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.343161.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Carter, Julian Robert. "Fundamental and applied measurements in ICP-MS." Thesis, University of Plymouth, 2002. http://hdl.handle.net/10026.1/1085.

Full text
Abstract:
Fundamental and applied aspects of ICP-MS have been investigated to gain an increased understanding of the technique and improve on its analytical capabilities. Dissociation temperatures of polyatomic ions were calculated using a double-focusing sector instrument, to obtain more reliable mass spectral data with controlled vapour introduction via a Dreschel bottle to allow accurate calculation of the ingredients in the plasma. The equilibrium temperature for the plasma, operated at 1280 W calculated using CO*, and as the thermometric probes, was c.a. 5800 - 7400 K, while using ArO* and ArC* as
APA, Harvard, Vancouver, ISO, and other styles
10

Schmidt, Benita. "Detection and Characterisation of Nanoparticles using Inductively Coupled Plasma Mass Spectrometry." Doctoral thesis, Humboldt-Universität zu Berlin, 2019. http://dx.doi.org/10.18452/20162.

Full text
Abstract:
In dieser Doktorarbeit wurde eine analytische Methode zur Charakterisierung metallischer Nanopartikel (NPs) entwickelt und die Methode bei der Untersuchung natürlicher Proben angewendet. Mit einem analytisches System bestehend aus einem Mikrotropfengenerator (microdroplet generator, MDG) zusammen mit einem pneumatischen Zerstäuber und einem induktiv gekoppeltem Plasma-Massenspektrometer (ICP-MS) konnte eine quantitative und qualitative Charakterisierung von NPs durchgeführt werden. Der MDG wurde verwendet um die Kalibrierungsfunktion für die massenspektrometrische Quantifizierung der Metalle
APA, Harvard, Vancouver, ISO, and other styles
More sources

Books on the topic "ICP mass spectrometer"

1

VanHaecke, Frank. Isotopic analysis: Fundamentals and applications using ICP-MS. Wiley-VCH, 2012.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
2

Thomas, Robert. Practical guide to ICP-MS: A tutorial for beginners. 2nd ed. CRC Press, 2008.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
3

Thomas, Robert. Practical guide to ICP-MS: A tutorial for beginners. 2nd ed. CRC Press, 2008.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
4

Thomas, Robert. Practical guide to ICP-MS: A tutorial for beginners. 2nd ed. CRC Press, 2008.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
5

Kapała, Jan. Metody interpretacji widm mas związków nieorganicznych i ich zastosowania w wybranych badaniach termodynamicznych. Oficyna Wydawnicza Politechniki Wrocławskiej, 2010.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
6

1970-, Speakman Robert J., and Neff Hector, eds. Laser ablation ICP-MS in archaeological research. University of New Mexico Press, 2005.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
7

Caro, Guillermo Manuel Muñoz. From photoprocessing of interstellar ice to amino acids and other organics. Universiteit Leiden, 2003.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
8

Todoli, José-Luis, and Jean-Michel Mermet. Liquid Sample Introduction in ICP Spectrometry: A Practical Guide. Elsevier Science & Technology Books, 2011.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
9

Michalski, Rajmund. Application of IC-MS and IC-ICP-MS in Environmental Research. Wiley & Sons, Limited, John, 2016.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
10

Michalski, Rajmund. Application of IC-MS and IC-ICP-MS in Environmental Research. Wiley & Sons, Incorporated, John, 2016.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
More sources

Book chapters on the topic "ICP mass spectrometer"

1

Thomas, Robert J. "How to Select an ICP Mass Spectrometer." In Measuring Heavy Metal Contaminants in Cannabis and Hemp. CRC Press, 2020. http://dx.doi.org/10.1201/9781003004158-30.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Thomas, Robert. "How to Evaluate an ICP Mass Spectrometer." In Practical Guide to ICP-MS and Other Atomic Spectroscopy Techniques, 4th ed. CRC Press, 2023. http://dx.doi.org/10.1201/9781003187639-26.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Sylvester, Paul. "Laser Ablation Inductively Coupled Mass Spectrometer (LA ICP-MS)." In Encyclopedia of Scientific Dating Methods. Springer Netherlands, 2014. http://dx.doi.org/10.1007/978-94-007-6326-5_75-1.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Sylvester, Paul. "Laser Ablation Inductively Coupled Mass Spectrometer (LA ICP-MS)." In Encyclopedia of Scientific Dating Methods. Springer Netherlands, 2015. http://dx.doi.org/10.1007/978-94-007-6304-3_75.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Neff, Hector. "Laser Ablation ICP-MS in Archaeology." In Mass Spectrometry Handbook. John Wiley & Sons, Inc., 2012. http://dx.doi.org/10.1002/9781118180730.ch37.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Mozhayeva, Darya, and Carsten Engelhard. "CE Coupled to ICP-MS and Single Particle ICP-MS for Nanoparticle Analysis." In Capillary Electrophoresis-Mass Spectrometry. Springer US, 2022. http://dx.doi.org/10.1007/978-1-0716-2493-7_16.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Cocherie, Alain, and Michèle Robert. "LA-MC-ICP-MS Applied to U-PB Zircon Geochronology." In Mass Spectrometry Handbook. John Wiley & Sons, Inc., 2012. http://dx.doi.org/10.1002/9781118180730.ch31.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Morton, Jackie, Zoë A. Quinn, Vladimir I. Baranov, et al. "ICP-MS Applications." In Inductively Coupled Plasma Mass Spectrometry Handbook. Blackwell Publishing Ltd., 2009. http://dx.doi.org/10.1002/9781444305463.ch9.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Vogt, Carla, and Christopher Latkoczy. "Laser Ablation ICP-MS." In Inductively Coupled Plasma Mass Spectrometry Handbook. Blackwell Publishing Ltd., 2009. http://dx.doi.org/10.1002/9781444305463.ch6.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Thomas, Robert J. "An Overview of ICP Mass Spectrometry." In Measuring Heavy Metal Contaminants in Cannabis and Hemp. CRC Press, 2020. http://dx.doi.org/10.1201/9781003004158-4.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Conference papers on the topic "ICP mass spectrometer"

1

Thiruvengetam, Prabaharan, G. John Langley, Julie Herniman, et al. "Monitoring Aging of Natural Ester Insulating Fluid using Supercritical Fluid Chromatography-Mass Spectrometry (SFC-MS)." In 2024 IEEE 5th International Conference on Dielectrics (ICD). IEEE, 2024. http://dx.doi.org/10.1109/icd59037.2024.10613221.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Han, Jiaxin, Yaxuan Yan, and Pengtao Jia. "Research on Feature Dimension Reduction Method of Serum Mass Spectrometry Data Based on Machine Learning." In 2024 9th International Conference on Intelligent Computing and Signal Processing (ICSP). IEEE, 2024. http://dx.doi.org/10.1109/icsp62122.2024.10743246.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Rodgers, Ryan P., Parviz Rahimi, Barry Messer, Terry Phillips, and Alan G. Marshall. "Advanced Evaluation of Crude Compositions for Optimum Corrosion Resistance and Processing Capabilities." In CORROSION 2006. NACE International, 2006. https://doi.org/10.5006/c2006-06582.

Full text
Abstract:
Abstract Naphthenic acids are minor constituents in most petroleum crudes; however, these acids have special significance due to their potential for corrosivity in refinery equipment. In order to evaluate the degree of corrosivity, it is important to identify the chemical nature of naphthenic acid constituents. This paper reports on a new Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (FT-ICR MS) technique to positively identify and provide information on the relative abundance of the naphthenic acid as well as other polar and nonpolar species present in crude oil without special
APA, Harvard, Vancouver, ISO, and other styles
4

Fredeen, Kenneth J. "Applications of Laser Sampling Inductively Coupled Plasma Mass Spectrometry." In Laser Applications to Chemical Analysis. Optica Publishing Group, 1992. http://dx.doi.org/10.1364/laca.1992.pd2.

Full text
Abstract:
Laser sampling inductively coupled plasma mass spectrometry (LS-ICP-MS) is a increasingly popular technique for the direct determination of trace elements in solid materials. In this technique, a high-power pulsed laser is used to vaporize a portion of a solid specimen. The sample vapor is then swept into an ICP discharge, which ionizes the vapor before it is subsequently sampled by a mass spectrometer.
APA, Harvard, Vancouver, ISO, and other styles
5

Quang Do, Vinh, Kinjal Ramani, Kerstin Thurow, and Heidi Fleischer. "Integration of a micro reactor system to a ICP mass spectrometer." In 2017 IEEE International Instrumentation and Measurement Technology Conference (I2MTC). IEEE, 2017. http://dx.doi.org/10.1109/i2mtc.2017.7969876.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Usman, Abida. "Optimization of Lead (Pb) Isotopes Measurement Using Quadrupole-Inductively Coupled Plasma Mass Spectrometer (Q-ICP-MS)." In Proceedings of the 18th International Conference on Heavy Metals in the Environment. openjournals ugent, 2016. http://dx.doi.org/10.21825/ichmet.71210.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Jacobsen, Stein, Christopher Parendo, Zachary Eriksen, Hairuo Fu, and Yvan Gérard. "The Nu Sapphire SP001 collision cell MC-ICP mass spectrometer: Application to high-precision measurements of K and Ca isotopes." In Goldschmidt2023. European Association of Geochemistry, 2023. http://dx.doi.org/10.7185/gold2023.20550.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Kanai, Taizo, Masahiro Furuya, Takahiro Arai, et al. "Effect of Two-Phase Flow Structure in Decontamination Factor of Filtered Containment Venting System." In 2014 22nd International Conference on Nuclear Engineering. American Society of Mechanical Engineers, 2014. http://dx.doi.org/10.1115/icone22-30385.

Full text
Abstract:
In order to gain the best use of filtered containment venting systems (FCVSs), the decomtamination factor of FCVSs is to be investigated as a function of system parameter including steam flow rate, pressure, temperature, water level, and operating time. A full-height test facilities were designed and constructed in Central Research Institute of Electric Power Industry (CRIEPI), Japan to evaluate the decontamination factor (DF) in FCVSs. The target types are the orifice and the venturi FCVSs. The height and the internal diameter of the cylindrical test vessel is 8 m and 0.5 m. Bubbly flows were
APA, Harvard, Vancouver, ISO, and other styles
9

Gupta, N. K. "Assessing the Impact of Equipment Aging on System Performance Using Simulation Modeling Methods." In ASME 2006 Pressure Vessels and Piping/ICPVT-11 Conference. ASMEDC, 2006. http://dx.doi.org/10.1115/pvp2006-icpvt-11-93061.

Full text
Abstract:
The radiological Inductively Coupled Plasma Mass Spectrometer (ICP-MS) is used to analyze the radioactive samples collected from different radioactive material processing operations at Savannah River Site (SRS). The expeditious processing of these samples is important for safe and reliable operations at SRS. As the radiological (RAD) ICP-MS machine ages, the experience shows that replacement parts and repairs are difficult to obtain on time for reliable operations after 5 years of service. A discrete event model using commercial software EXTEND was prepared to assess the impact on sample turn
APA, Harvard, Vancouver, ISO, and other styles
10

Pilecka-Ulcugaceva, Jovita, Inga Grinfelde, Anda Bakute, Juris Burlakovs, and Maris Bertins. "THE SPATIAL AND TEMPORAL DISTRIBUTION OF ALUMINUM EMISSIONS IN AIR FROM TRANSPORT IN JELGAVA." In 23rd SGEM International Multidisciplinary Scientific GeoConference 2023. STEF92 Technology, 2023. http://dx.doi.org/10.5593/sgem2023/4.1/s19.44.

Full text
Abstract:
The number of transport units in cities is increasing every year. This trend contributes to air pollution problems in many rapidly urbanizing countries. Various heavy metals and other chemical elements, including aluminum, have been related to air quality degradation. Poor air quality affects people, especially young children, the elderly, and people with chronic illnesses, causing health problems and aggravating existing problems. The aim of the research is to find out which parts of the city of Jelgava have the highest risk of aluminum pollution in the air. In the research was used Jelgava c
APA, Harvard, Vancouver, ISO, and other styles

Reports on the topic "ICP mass spectrometer"

1

Benn, D., R. Linnen, and T. Martins. Evaluating white mica as an indicator mineral for lithium bearing pegmatites, Wekusko Lake pegmatite field, Manitoba, Canada. Natural Resources Canada/CMSS/Information Management, 2021. http://dx.doi.org/10.4095/328982.

Full text
Abstract:
This project investigates the potential use of white micas as an indicator mineral within Li-bearing pegmatites and the potential of field portable techniques, such as Raman spectroscopy and Laser Induced Breakdown Spectroscopy (LIBS) as real-time techniques in exploration. The pegmatites in the Wekusko Lake field, Manitoba, Canada, display five zones of varying mineralization. White micas display two textures in the field (primary igneous and secondary) and four textures were identified by backscattered electron imaging (poor zonation, rimmed, patchy and exsolution). The white micas were anal
APA, Harvard, Vancouver, ISO, and other styles
2

Gottlieb, E. LaserChron (Nu Instruments High Resolution ICP Mass Spectrometer) data of Triassic and Carboniferous outcrop samples from the Karen Creek, Ivishak, and Nuka Formations, western and eastern Brooks Range, Alaska. Alaska Division of Geological & Geophysical Surveys, 2012. http://dx.doi.org/10.14509/24666.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Gottlieb, E. LaserChron (Nu Instruments High Resolution ICP Mass Spectrometer) data of core from the East Simpson Test Well #1, Ikpikpuk Test Well #1, Inigok Test Well #1, and Peard Test Well #1 wells. Alaska Division of Geological & Geophysical Surveys, 2012. http://dx.doi.org/10.14509/24665.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Yin, N. Applications of inductively coupled plasma mass spectrometry (ICP-MS) to geoanalysis. Natural Resources Canada/ESS/Scientific and Technical Publishing Services, 1993. http://dx.doi.org/10.4095/193301.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Lewis, L. A. {sup 99}Tc bioassay by inductively coupled plasma mass spectrometry (ICP-MS). Office of Scientific and Technical Information (OSTI), 1998. http://dx.doi.org/10.2172/658288.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Plouffe, A., D. Petts, I M Kjarsgaard, and M. Polivchuk. Laser ablation inductively coupled plasma mass spectrometry mapping of porphyry -related epidote from south-central British Columbia. Natural Resources Canada/CMSS/Information Management, 2023. http://dx.doi.org/10.4095/331671.

Full text
Abstract:
The microscopic composition of thirteen samples of epidote related to porphyry Cu mineralization was mapped using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) at the Geological Survey of Canada. The objective of this research is to improve the indicator mineral method of mineral exploration in glaciated terrains by utilizing the trace element composition of epidote. Six bedrock samples from porphyry Cu deposits of south-central British Columbia (Gibraltar, Mount Polley and Woodjam), three bedrock samples from the Nicola Group located close (<2 km) from the
APA, Harvard, Vancouver, ISO, and other styles
7

Gallimore, David L. Uncertainty Measurement for Trace Element Analysis of Uranium and Plutonium Samples by Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES) and Inductively Coupled Plasma-Mass Spectrometry (ICP-MS). Office of Scientific and Technical Information (OSTI), 2012. http://dx.doi.org/10.2172/1043523.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Bourdeau, J. E., and R. D. Dyer. Regional-scale lake-sediment sampling and analytical protocols with examples from the Geological Survey of Canada. Natural Resources Canada/CMSS/Information Management, 2023. http://dx.doi.org/10.4095/331911.

Full text
Abstract:
Regional-scale lake sediment surveys have been successfully used since the 1970s as a means for reconnaissance geochemical exploration. Lake sediment sampling is typically performed in areas with a lack of streams and an overabundance of small-sized (=5 km across) lakes. Lake sediments are known to have major, minor and trace element concentrations that reflect the local geology. Overall, lake sediment surveys are planned and conducted following four distinct stages: 1) background research, 2) orientation survey, 3) regional survey, and 4) detailed survey. At the Geological Survey of Canada, s
APA, Harvard, Vancouver, ISO, and other styles
9

Longerich, H. P. Determination of 147Sm/144Nd isotope ratios in geological materials using inductively coupled plasma-mass spectrometry (ICP-MS). Natural Resources Canada/ESS/Scientific and Technical Publishing Services, 1993. http://dx.doi.org/10.4095/193310.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Balaram, V. Rare-earth element analysis of iron-formation reference samples by inductively coupled plasma mass spectrometry (ICP-MS). Natural Resources Canada/ESS/Scientific and Technical Publishing Services, 1993. http://dx.doi.org/10.4095/164254.

Full text
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!