To see the other types of publications on this topic, follow the link: IEEE 14 bus system.

Journal articles on the topic 'IEEE 14 bus system'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 journal articles for your research on the topic 'IEEE 14 bus system.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse journal articles on a wide variety of disciplines and organise your bibliography correctly.

1

Hiwarkar, Dr Chandrashekhar S., Abhay M. Halmare, Anurag A. Belsare, Nitin B. Mohriya, and Roshan Milmile. "Load Flow Analysis on IEEE 14 Bus System." International Journal for Research in Applied Science and Engineering Technology 10, no. 4 (2022): 1572–74. http://dx.doi.org/10.22214/ijraset.2022.41590.

Full text
Abstract:
Abstract: This article presents a load flow analysis of an IEEE14 BUS system using the Newton-Raphson method, which simplifies the analysis of load balancing problems. The software used for the programming platform is MATLAB. This paper gives an overview of the electrical performance and power flows (real and reactive) under a steady state. There are various methods for load flow computations. The gauss-seidel method is more popular in smaller systems because of less computational time. In the case of larger systems computation time increases in this condition, the Newton-Raphson method is pre
APA, Harvard, Vancouver, ISO, and other styles
2

Araga, Idris A., and A. E. Airoboman. "Enhancement of voltage stability in an interconnected network using unified power flow controller." Journal of Advances in Science and Engineering 4, no. 1 (2021): 65–74. http://dx.doi.org/10.37121/jase.v4i1.141.

Full text
Abstract:
In this paper, the optimal placement of Unified Power Flow Controllers (UPFC) in a large-scale transmission network in order to improve the loadability margin was considered. In other to achieve this aim, the Line Stability Factor (LQP) as a technique for the optimal location of UPFC in the IEEE 14-bus network and 56-bus Nigerian national grid was adopted. The power injection model for the UPFC was employed to secure improvements in the loading margin of the IEEE 14-bus network and 56-bus Nigerian national grid system. Continuation power flow was used to assess the effect of UPFC on the loadab
APA, Harvard, Vancouver, ISO, and other styles
3

Chakravorty, J., and J. Saraswat. "Deciding Optimal Location of DPFC in Transmission Line Using Artificial Algae Algorithm." Engineering, Technology & Applied Science Research 9, no. 2 (2019): 3978–80. http://dx.doi.org/10.48084/etasr.2667.

Full text
Abstract:
In this paper, the application of artificial algae algorithm (AAA) in optimal placement distributed power flow controller (DPFC) with MCFC in transmission networks has been proposed The proposed method is tested on IEEE 14- bus system and the results are discussed. The biggest advantage of DPFC is that it can control the active and reactive power flow and bus voltages, simultaneously. In this paper, the optimal placement of one DPFC in IEEE-14 bus system and then optimal placement of two DPFCs in IEEE-14 bus system has been proposed. Optimal placement of DPFC in power system by AAA leads to in
APA, Harvard, Vancouver, ISO, and other styles
4

Chakravorty, Jaydeep, and Jyoti Saraswat. "Deciding Optimal Location of DPFC in Transmission Line Using Artificial Algae Algorithm." Engineering, Technology & Applied Science Research 9, no. 2 (2019): 3978–80. https://doi.org/10.5281/zenodo.2647823.

Full text
Abstract:
In this paper, the application of artificial algae algorithm (AAA) in optimal placement distributed power flow controller (DPFC) with MCFC in transmission networks has been proposed The proposed method is tested on IEEE 14- bus system and the results are discussed. The biggest advantage of DPFC is that it can control the active and reactive power flow and bus voltages, simultaneously. In this paper, the optimal placement of one DPFC in IEEE-14 bus system and then optimal placement of two DPFCs in IEEE-14 bus system has been proposed. Optimal placement of DPFC in power system by AAA leads to in
APA, Harvard, Vancouver, ISO, and other styles
5

Gongada, Sandhya Rani, Muktevi Chakravarthy, and Bhukya Mangu. "Power system contingency classification using machine learning technique." Bulletin of Electrical Engineering and Informatics 11, no. 6 (2022): 3091–98. http://dx.doi.org/10.11591/eei.v11i6.4031.

Full text
Abstract:
One of the most effective ways for estimating the impact and severity of line failures on the static security of the power system is contingency analysis. The contingency categorization approach uses the overall performance index to measure the system's severity (OPI). The newton raphson (NR) load flow technique is used to extract network variables in a contingency situation for each transmission line failure. Static security is categorised into five categories in this paper: secure (S), critically secure (CS), insecure (IS), highly insecure (HIS), and most insecure (MIS). The K closest neighb
APA, Harvard, Vancouver, ISO, and other styles
6

Sandhya, Rani Gongada, Chakravarthy Muktevi, and Mangu Bhukya. "Power system contingency classification using machine learning technique." Bulletin of Electrical Engineering and Informatics 11, no. 6 (2022): 3091~3098. https://doi.org/10.11591/eei.v11i6.4031.

Full text
Abstract:
One of the most effective ways for estimating the impact and severity of line failures on the static security of the power system is contingency analysis. The contingency categorization approach uses the overall performance index to measure the system's severity (OPI). The newton raphson (NR) load flow technique is used to extract network variables in a contingency situation for each transmission line failure. Static security is categorised into five categories in this paper: secure (S), critically secure (CS), insecure (IS), highly insecure (HIS), and most insecure (MIS). The K closest ne
APA, Harvard, Vancouver, ISO, and other styles
7

Mohammad, Yousuf, and Abdul Ghani. "Determine Weakest Bus for IEEE 14 Bus Systems." International Journal of Computer Applications 182, no. 27 (2018): 7–10. http://dx.doi.org/10.5120/ijca2018918087.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Paulraj Jayasimman, I., G. Jenitha, C. Gnanavel Chinnaraj, and J. Joseline Manora. "Graph Energy Value Of IEEE-14 Bus System." Journal of Physics: Conference Series 1850, no. 1 (2021): 012016. http://dx.doi.org/10.1088/1742-6596/1850/1/012016.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Hyacinth, Lourdusamy Ramya, and Venugopal Gomathi. "Optimal PMU Placement Technique to Maximize Measurement Redundancy Based on Closed Neighbourhood Search." Energies 14, no. 16 (2021): 4782. http://dx.doi.org/10.3390/en14164782.

Full text
Abstract:
This paper proposes a method for the optimal placement of phasor measurement units (PMUs) for the complete observability of a power system based on the degree of the neighbourhood vertices. A three-stage algorithm is used to determine the minimum number of PMUs needed to make the system observable. The key objective of the proposed methodology is to minimize the total number of PMUs to completely observe a power system network and thereby minimize the installation cost. In addition, the proposed technique also focuses on improving the measurement redundancy. The proposed method is applied on s
APA, Harvard, Vancouver, ISO, and other styles
10

Kumar, K. Sowjan, B. Nagaraju, K. Satvika, et al. "Optimal Placement and Size Selection 0f Photovoltaic System in IEEE 14 Bus Power Transmission Network." International Journal of Innovative Research in Engineering and Management 9, no. 4 (2022): 161–68. http://dx.doi.org/10.55524/ijirem.2022.9.4.31.

Full text
Abstract:
The analysis and design of energy systems is usually carried out using power flow analysis. This is used for determining the magnitude and phase angle of the load buses and the real and reactive power flows on the transmission lines, as well as the real and reactive powers injected into the buses. In this paper single photo voltaic system is connected to IEEE 14 bus system and run the power flow system and find thecomparison between single and double voltaic systems. In the paper of larger systems computation time increases in this condition, Newton Raphson method.This paper aims to develop a
APA, Harvard, Vancouver, ISO, and other styles
11

Wang, Zhong-Jie, Shu-Ying Yuan, Xuan Zhao, and Cheng-Chao Lu. "Differential evolution-based optimal placement of phase measurement unit considering measurement redundancy." International Journal of Modeling, Simulation, and Scientific Computing 06, no. 01 (2015): 1550016. http://dx.doi.org/10.1142/s1793962315500166.

Full text
Abstract:
Phase measurement unit (PMU) is the key equipment for electric power system, which has been used to monitor and control power grid. But it is too expensive to deploy on each bus. So, we need to investigate how to deploy PMU to satisfy our observation requirements with minimum PMU numbers. This problem is called the optimal PMU placement (OPP). In this paper, we employ differential evolution (DE) algorithm to solve the OPP problem. Our optimization target is to make the power grid completely observable with maximum redundancy and minimum number of PMU. The proposed method is tested on IEEE 14-b
APA, Harvard, Vancouver, ISO, and other styles
12

Shreya, K. Mysore, and Ankaliki Shekhappa. "Topology transformation approach for optimal PMU placement for monitoring and control of power system." i-manager's Journal on Power Systems Engineering 12, no. 1 (2024): 16. http://dx.doi.org/10.26634/jps.12.1.21081.

Full text
Abstract:
The efficient placement of Phasor Measurement Units (PMUs) is crucial to minimize their number while ensuring full power system observability. A power system is deemed observable when the voltage at every bus is known. This study proposes a topology transformation approach that combines a Zero-Injection Bus (ZIB) with one of its neighboring buses to achieve optimal PMU placement. The choice of the neighboring bus for combination with the ZIB significantly influences the outcome of the merging process. To identify the optimal candidate bus for merging with the ZIB, the proposed approach utilize
APA, Harvard, Vancouver, ISO, and other styles
13

Gupta, Santosh Kumar, and Sanjeev Kumar Mallik. "Fast assessment of the voltage stability using reconfigured power system network and artificial neural network approaches." Engineering Research Express 5, no. 3 (2023): 035047. http://dx.doi.org/10.1088/2631-8695/acf189.

Full text
Abstract:
Abstract Planning and running power systems must take voltage stability into account. Instability is mostly caused by the power system’s failure to supply the demand for reactive power. The voltage stability margin must be understood by utilities if they are to operate the power system with the highest level of security and dependability. This paper uses reconfigured 12 bus, 10 bus, and 8-bus reconfigured networks of the interconnected IEEE 14 bus system to demonstrate the proposed quick method for assessing the voltage stability. The original (IEEE 14 bus) and the reconfigured (12 bus, 10 bus
APA, Harvard, Vancouver, ISO, and other styles
14

LILIK, J. AWALIN, ABD. HALIM SYAHIRA, RAMLI AZUANA, and ISMAIL BAZILAH. "PMU PLACEMENT BASED FAULT LOCATION USING MULTI OBJECTIVES SHORTEST PATH ALGORITHM." Seybold Report 17, no. 05 (2022): 10–23. https://doi.org/10.5281/zenodo.6555856.

Full text
Abstract:
<strong>Abstract</strong> The ability of the system to supply all kinds of loads during natural problems or fault has yet to be addressed. This work focuses on designing a wide-area measurement system to manage and control the power system during faults. IEEE 14 bus system and measurement of voltage and current were simulated by using PSCAD.&nbsp; In order to observe the effectiveness of measurement during a fault, multiobjective shortest path algorithm is considered in this paper. There are 19 fault cases have been simulated. Based on the calculation by utilizing multiobjective shortest path
APA, Harvard, Vancouver, ISO, and other styles
15

P, Olaogun. "Application of Static Synchronous Compensator for Improvement of Power System Transient Stability." Arid-zone Journal of Basic and Applied Research 4, no. 1 (2024): 65–87. http://dx.doi.org/10.55639/607.454443.

Full text
Abstract:
Transient stability is the power system’s ability to maintain synchronism when exposed to severe disturbances such as loss of generation, rapid load changes, transmission lines tripping, switching operations and faults. Transient instability causes cascading outages, system collapse and economical losses. This study employed static synchronous compensator (STATCOM) for power system transient stability improvement. The system’s steady state and transient responses were respectively modelled with Newton-Raphson power flow and modified-Euler linearized swing equations. A balanced three-phased sho
APA, Harvard, Vancouver, ISO, and other styles
16

Ibrahim, Alhamrouni, Ismail Rasyid, Salem Mohamed, Ismail Bazilah, Jusoh Awang, and Sutikno Tole. "Integration of STATCOM and ESS for power system stability improvement." International Journal of Power Electronics and Drive System (IJPEDS) 11, no. 2 (2020): 859–69. https://doi.org/10.11591/ijpeds.v11.i2.pp859-869.

Full text
Abstract:
The power system enters a state of voltage instability due to the inability of the power system to meet the demand for active power and reactive power due to the increase of system load. In order to stabilize the power system, the installation of STATCOM and ESS needs to be performed. The main objective of this paper is to identify the suitable size and location of STATCOM and ESS for power system stability improvement. First, the IEEE 14 bus system was simulated using DIgSILENT software in ideal condition. Then, the system loadability was increased up to 200% of initial value to locate the we
APA, Harvard, Vancouver, ISO, and other styles
17

Dhana Sai Sri, M., and P. Srinivasa Varma. "Evaluation and Analysis of Available Transfer Capability in Deregulated Power System Environment." International Journal of Engineering & Technology 7, no. 1.8 (2018): 188. http://dx.doi.org/10.14419/ijet.v7i1.8.16399.

Full text
Abstract:
Reliability of network is need of the hour in the present power system market and is constrained by capability of the network. The network calculations are performed using accurate and high efficient strategies. In order to perform power transactions in the system, the computation of available transfer capability is essential which a metric of capability of the system. Generally, effect wattless power is not taken into account in the methodologies for computation of linear available transfer capability. In this paper, a methodology which considers the reactive power flows for enhancement of li
APA, Harvard, Vancouver, ISO, and other styles
18

Ibrahim, Ahmad Asrul, Khairuddin Khalid, Hussain Shareef, and Nor Azwan Mohamed Kamari. "A Bounded Exhaustive Search Technique for Optimal Phasor Measurement Unit Placement in Power Grids." Symmetry 12, no. 12 (2020): 2021. http://dx.doi.org/10.3390/sym12122021.

Full text
Abstract:
This paper proposes a technique to determine the possible optimal placement of the phasor measurement unit (PMU) in power grids for normal operating conditions. All possible combinations of PMU placement, including infeasible combinations, are typically considered in finding the optimal solution, which could be a massive search space. An integer search algorithm called the bounded search technique is introduced to reduce the search space in solving a minimum number of PMU allocations whilst maintaining full system observability. The proposed technique is based on connectivity and symmetry cons
APA, Harvard, Vancouver, ISO, and other styles
19

Jethmalani, C. H. Ram, Poornima Dumpa, Sishaj P. Simon, and K. Sundareswaran. "Transmission Loss Calculation using A and B Loss Coefficients in Dynamic Economic Dispatch Problem." International Journal of Emerging Electric Power Systems 17, no. 2 (2016): 205–16. http://dx.doi.org/10.1515/ijeeps-2015-0181.

Full text
Abstract:
Abstract This paper analyzes the performance of A-loss coefficients while evaluating transmission losses in a Dynamic Economic Dispatch (DED) Problem. The performance analysis is carried out by comparing the losses computed using nominal A loss coefficients and nominal B loss coefficients in reference with load flow solution obtained by standard Newton-Raphson (NR) method. Density based clustering method based on connected regions with sufficiently high density (DBSCAN) is employed in identifying the best regions of A and B loss coefficients. Based on the results obtained through cluster analy
APA, Harvard, Vancouver, ISO, and other styles
20

Mohammad, Naseem Akhlakh, Khan Ahmad Ahmad, Minai Faiz, and Hameed Salman. "OPTIMAL LOCATION OF TCSC FOR REDUCTION IN SYSTEM LOSSES." International Journal of Advances in Engineering & Scientific Research 1, no. 7 (2014): 35–42. https://doi.org/10.5281/zenodo.10725336.

Full text
Abstract:
&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; <em>The existing transmission system are currently facing challenges to enhance &nbsp;the power transfer capabilities. This is where the Flexible AC Transmission Systems (FACTS) technology comes into effect. With relatively low investment, compared to new transmission or generation facilities, the FACTS technology allows the industries to better utilization of &nbsp;the existing transmission and generation reserves, while enhancing the power sy
APA, Harvard, Vancouver, ISO, and other styles
21

Chakravorty, J., and J. Saraswat. "Improving Power Flow Capacity of Transmission Lines Using DPFC with a PEM Fuel Cell." Engineering, Technology & Applied Science Research 9, no. 6 (2019): 4883–85. http://dx.doi.org/10.48084/etasr.3155.

Full text
Abstract:
The electrical power system is one complex architecture integrating generation, transmission, distribution, and utilization sections. The exponential increase in power requirements made this system more complex and dynamic. Providing good quality and uninterrupted power has become a challenge. In this respect, FACTS devices are playing a vital role in improving power quality and also in increasing the transmission capacity of lines. In this paper. Distributed Power Flow Controller (DPFC), with a PEM fuel cell, has been used in an IEEE-14 bus system to improve system power flow capacity. The pr
APA, Harvard, Vancouver, ISO, and other styles
22

Chakravorty, J., and J. Saraswat. "Improving Power Flow Capacity of Transmission Lines Using DPFC with a PEM Fuel Cell." Engineering, Technology & Applied Science Research 9, no. 6 (2019): 4883–85. https://doi.org/10.5281/zenodo.3566122.

Full text
Abstract:
The electrical power system is one complex architecture integrating generation, transmission, distribution, and utilization sections. The exponential increase in power requirements made this system more complex and dynamic. Providing good quality and uninterrupted power has become a challenge. In this respect, FACTS devices are playing a vital role in improving power quality and also in increasing the transmission capacity of lines. In this paper. Distributed Power Flow Controller (DPFC), with a PEM fuel cell, has been used in an IEEE-14 bus system to improve system power flow capacity. The pr
APA, Harvard, Vancouver, ISO, and other styles
23

Mandava, Srihari, Vanishree J, and Ramesh V. "A Spanning Tree Approach in Placing Multi-channel and Minimum Channel PMU’s for Power System Observability." International Journal of Electrical and Computer Engineering (IJECE) 5, no. 3 (2015): 518. http://dx.doi.org/10.11591/ijece.v5i3.pp518-524.

Full text
Abstract:
Synchronized phasor measurements have become the measurement technique of choice for electric power systems. They provide positive sequence voltage and current measurements synchronized to within a microsecond. The objective is to use the spanning tree approach and tree search technique for optimal placement of multichannel and minimum channel synchronized phasor measurement units (PMUs) in order to have full observability of Power System. The novel concept of depth of observability is used and its impact on the number of PMU placements is explained. The spanning tree approach is used for the
APA, Harvard, Vancouver, ISO, and other styles
24

Thota, Praveen Kumar, Ganapathy Somaskandan, and Manikandan Mani. "The Voltage stability analysis for grid-connected PV system using optimized control tested by IEEE 14 &30 bus system." International Journal of Experimental Research and Review 30 (April 30, 2023): 109–18. http://dx.doi.org/10.52756/ijerr.2023.v30.012.

Full text
Abstract:
In the research work presented in this paper, we present a grid-connected solar photovoltaic (PV) system, which is focused on various factors, such as the low oxide emission and high energy efficiency of the system. Solar PV systems have a greater impact on grid stability than any other energy source. IEEE 14 bus test system is used to verify the voltage stability of the bus. It is a concept of a methodology using a RNN-based PV controller in conjunction with a Landsman converter to maintain the PV system's voltage-gain ratio and improve it. Conversely, an ANN-based boost Integrated Landsman C
APA, Harvard, Vancouver, ISO, and other styles
25

Awalin, Lilik Jamilatul, Syahirah Abd Halim, Nor Azuana Ramli, Jafferi Jafferi, and Mohd Syukri Ali. "Wide area monitoring system control management of theIEEE-14 bus system using least square support vector regression." Indonesian Journal of Electrical Engineering and Computer Science 27, no. 2 (2022): 780–92. https://doi.org/10.11591/ijeecs.v27.i2.pp780-792.

Full text
Abstract:
The wide area monitoring system (WAMS) records and monitors every fault or disturbance that occurs in a power system network using phasor measuring units (PMUs). Extensive monitoring of the condition of theelectrical power system can ensure the sustainability of reliable energy. Theaccuracy of the PMUs placement can be determined using the least squaresupport vector regression (LS-SVR) technique. The primary goal of this study is to assess the level of accuracy of the PMUs placement using meansquare error (MSE). First, the IEEE-14 bus system equipped with PMUs was built in Matlab software usin
APA, Harvard, Vancouver, ISO, and other styles
26

Gupta, Santosh Kumar, Ashish Ranjan, Dhananjay Kumar, et al. "Assessment of photovoltaic generation penetration effect on the maximum loadability of the system." Engineering Research Express 6, no. 1 (2024): 015312. http://dx.doi.org/10.1088/2631-8695/ad2d4a.

Full text
Abstract:
Abstract This paper proposed a method to investigate the effect of increasing PV penetration on the voltage stability of an IEEE 14-bus test system considering maximum PV penetration and system loadability limit. The critical bus of the test system has been decided based on nose curve analysis. The solar PV system is deployed with the most critical bus of the system. The effect of increasing PV penetration on the improvement in the loading capacity of various power system components like transmission lines, transmission line transformers, and generators is investigated over the adopted test sy
APA, Harvard, Vancouver, ISO, and other styles
27

Thotakura, Bharath kumar, Hema Bhargavi Borra, and Chinmai Alla. "A novel petri nets algorithm using conditional probability for the evaluation of composite power system reliability." International Journal of Engineering & Technology 7, no. 2 (2018): 564. http://dx.doi.org/10.14419/ijet.v7i2.10909.

Full text
Abstract:
Reliability of an electrical power system plays a vital role in providing continuous power supply to consumers with greater quality. The power demand is increasing day by day due to the increased population, modern society and are seeking highly reliable power. The assessment of reliability is very difficult due to the presence of large number of components and complex power system network con-figurations. This paper address a novel useful step by step algorithm for the assessment of average power availability at load buses us-ing the concept of modified Petri nets with conditional probability
APA, Harvard, Vancouver, ISO, and other styles
28

R. Sukhesh, H., Senthil Vadivu U., Prabhakar Karthikey, and . "Optimal Placement of Fuzzy based UPQC Topologies with Distributed Generation for Power Quality Enhancement in IEEE 14 Bus System." International Journal of Engineering & Technology 7, no. 4.10 (2018): 99. http://dx.doi.org/10.14419/ijet.v7i4.11.20817.

Full text
Abstract:
An Unified Power Quality Conditioner (UPQC), is a combination of shunt and series Active Power Filter (APF), has become a standard accepted solution in the area of current and voltage harmonics mitigation of a power system network. This paper furnishes a comparative analysis of the power quality enhancement and optimization in positioning for three different VSI based UPQC system configurations namely: 3P3W UPQC topology, 3P4W UPQC based on 2C shunt inverter topology and 3P4W UPQC based on 4L shunt inverter topology, all supported with the Fuzzy Logic Controller (FLC), placed at different loca
APA, Harvard, Vancouver, ISO, and other styles
29

Ghosh, Pronob K., Soumesh Chatterjee, and Anik Tahabilder. "Graph-Theory Based Optimal PMU Allocation Considering ZIB Effects." Instrumentation Mesure Métrologie 19, no. 4 (2020): 297–300. http://dx.doi.org/10.18280/i2m.190407.

Full text
Abstract:
Continuous monitoring is the prerequisite for secure operation and efficient control of power system. This paper presents a new and straightforward approach to monitor the system efficiently. Optimal PMU placement (OPP) deals with the complete system observability with a minimum number of PMU. The Modified Graph theoretic configuration has been presented here to select some strategic locations for PMU installation. Initially, a new technique has been used here to form spanning tree from its system graph. Some standard bus systems i.e. IEEE 7-bus, IEEE 14-bus, and 30-bus have been used to test
APA, Harvard, Vancouver, ISO, and other styles
30

Corpus, Marco Junior Ticllacuri, and Jonatas B. Leite. "Evaluation of FACTS Contributions Using Branch Flow Model and Newton–Raphson Algorithm." Energies 17, no. 4 (2024): 918. http://dx.doi.org/10.3390/en17040918.

Full text
Abstract:
Flexible alternating current transmission systems (FACTSs) have been widely incorporated in electric power systems in order to control system parameters. This paper proposes the modeling of four FACTS devices, using the Branch Flow Model (BF) as an optimization problem to reduce the complexity of the Newton–Raphson (NR) load flow code with FACTS devices. The devices are represented as variable impedances, as a function of a firing angle, and as voltage source converters (VSCs) located on the buses and transmission lines. This proposed model solves the problem associated with the selection of a
APA, Harvard, Vancouver, ISO, and other styles
31

Liu, Bin, Feng Liu, Bingxu Zhai, and Haibo Lan. "Investigating continuous power flow solutions of IEEE 14‐bus system." IEEJ Transactions on Electrical and Electronic Engineering 14, no. 1 (2018): 157–59. http://dx.doi.org/10.1002/tee.22773.

Full text
APA, Harvard, Vancouver, ISO, and other styles
32

Hilal, Ahmad Bhat*1 &. Er. Ravinder Kaur2. "POWER QUALITY IMPROVEMENT ON 14 BUS IEEE SYSTEM USING UPQC." INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY 7, no. 8 (2018): 526–37. https://doi.org/10.5281/zenodo.1402447.

Full text
APA, Harvard, Vancouver, ISO, and other styles
33

Adegoke, Samson Ademola, Yanxia Sun, and Zenghui Wang. "Minimization of Active Power Loss Using Enhanced Particle Swarm Optimization." Mathematics 11, no. 17 (2023): 3660. http://dx.doi.org/10.3390/math11173660.

Full text
Abstract:
Identifying the weak buses in power system networks is crucial for planning and operation since most generators operate close to their operating limits, resulting in generator failures. This work aims to identify the critical/weak node and reduce the system’s power loss. The line stability index (Lmn) and fast voltage stability index (FVSI) were used to identify the critical node and lines close to instability in the power system networks. Enhanced particle swarm optimization (EPSO) was chosen because of its ability to communicate with better individuals, making it more efficient to obtain a p
APA, Harvard, Vancouver, ISO, and other styles
34

Awalin, Lilik Jamilatul, Syahirah Abd Halim, Nor Azuana Ramli, Jafferi Bin Jamaludin, and Mohd Syukri Ali. "Wide area monitoring system control management of the IEEE-14 bus system using least square support vector regression." Indonesian Journal of Electrical Engineering and Computer Science 27, no. 2 (2022): 780. http://dx.doi.org/10.11591/ijeecs.v27.i2.pp780-792.

Full text
Abstract:
The &lt;span&gt;wide area monitoring system (WAMS) records and monitors every fault or disturbance that occurs in a power system network using phasor measuring units (PMUs). Extensive monitoring of the condition of the electrical power system can ensure the sustainability of reliable energy. The accuracy of the PMUs placement can be determined using the least square support vector regression (LS-SVR) technique. The primary goal of this study is to assess the level of accuracy of the PMUs placement using mean square error (MSE). First, the IEEE-14 bus system equipped with PMUs was built in Matl
APA, Harvard, Vancouver, ISO, and other styles
35

Chillab, Riyadh Kamil, Aqeel S. Jaber, Mouna Ben Smida, and Anis Sakly. "Optimal DG Location and Sizing to Minimize Losses and Improve Voltage Profile Using Garra Rufa Optimization." Sustainability 15, no. 2 (2023): 1156. http://dx.doi.org/10.3390/su15021156.

Full text
Abstract:
Distributed generation (DG) refers to small generating plants that usually develop green energy and are located close to the load buses. Thus, reducing active as well as reactive power losses, enhancing stability and reliability, and many other benefits arise in the case of a suitable selection in terms of the location and the size of the DGs, especially in smart cities. In this work, a new nature-inspired algorithm called Garra Rufa optimization is selected to determine the optimal DG allocation. The new metaheuristic algorithm stimulates the massage fish activity during finding food using MA
APA, Harvard, Vancouver, ISO, and other styles
36

Isaac, Samuel, Soyemi Adebola, Awelewa Ayokunle, Katende James, and Awosope Claudius. "Voltage collapse prediction using artificial neural network." International Journal of Electrical and Computer Engineering (IJECE) 11, no. 1 (2021): 124. http://dx.doi.org/10.11591/ijece.v11i1.pp124-132.

Full text
Abstract:
Unalleviated voltage instability frequently results in voltage collapse; which is a cause of concern in power system networks across the globe but particularly in developing countries. This study proposed an online voltage collapse prediction model through the application of a machine learning technique and a voltage stability index called the new line stability index (NLSI_1). The approach proposed is based on a multilayer feed-forward neural network whose inputs are the variables of the NLSI_1. The efficacy of the method was validated using the testing on the IEEE 14-bus system and the Niger
APA, Harvard, Vancouver, ISO, and other styles
37

Samuel, Isaac, Adebola Soyemi, Ayokunle Awelewa, James Katende, and Claudius Awosope. "Voltage collapse prediction using artificial neural network." International Journal of Electrical and Computer Engineering (IJECE) 11, no. 1 (2021): 124–32. https://doi.org/10.11591/ijece.v11i1.pp124-132.

Full text
Abstract:
Unalleviated voltage instability frequently results in voltage collapse; which is a cause of concern in power system networks across the globe but particularly in developing countries. This study proposed an online voltage collapse prediction model through the application of a machine learning technique and a voltage stability index called the new line stability index (NLSI_1). The approach proposed is based on a multilayer feed-forward neural network whose inputs are the variables of the NLSI_1. The efficacy of the method was validated using the testing on the IEEE 14-bus system and the Niger
APA, Harvard, Vancouver, ISO, and other styles
38

Pandey, Vipin Kumar, and Dr Malaya Saurava Dash. "MODELING OF 14 BUS SYSTEM WITH UPFC FOR TRANSIENT STABILITY ENHANCEMENT." SMART MOVES JOURNAL IJOSCIENCE 5, no. 4 (2019): 8. http://dx.doi.org/10.24113/ijoscience.v5i4.219.

Full text
Abstract:
The revolution of Power Electronics Technology has given opportunities for developing the FACTS devices for stable operation of power system. In the last two decades number of Power Electronic based devices are implemented and known as FACTS (Flexible AC transmission System).These devices are effectively used for voltage control, power flow control, harmonic elimination, damping oscillation and improving transient stability and minimization of losses. Static and Transient stability enhancement of IEEE 14 bus system is done with the help of UPFC. Fault is created at a bus and the results show t
APA, Harvard, Vancouver, ISO, and other styles
39

Haj-ahmed, Mohammed, Mais M. Aldwaik, and Dia Abualnadi. "Optimal Allocation of Phasor Measurement Units Using Particle Swarm Optimization: An Electric Grid Planning Perspective." Energies 18, no. 5 (2025): 1225. https://doi.org/10.3390/en18051225.

Full text
Abstract:
In this paper, the particle swarm optimization (PSO) technique is used to optimally allocate phasor measurement units (PMUs) within standard test systems and a real-world power system. PMUs are allocated at system substations in a manner that ensures complete system observability while minimizing installation costs. This study considers IEEE 14-, 30-, and 57-bus standard test systems, along with the Jordanian national high-voltage grid. The optimal allocation was performed separately on the 132 kV and 400 kV buses of the Jordanian grid. Additionally, a novel technique for further minimization
APA, Harvard, Vancouver, ISO, and other styles
40

Okorie, Patrick, Abdullahi Kunya, Yusuf Jibril, and Adam Abubakar. "Protection Coordination of Distribution Network with Optimally Placed Distribution Generation." ELEKTRIKA- Journal of Electrical Engineering 18, no. 3 (2019): 13–20. http://dx.doi.org/10.11113/elektrika.v18n3.171.

Full text
Abstract:
In this study, optimal distribution network protection coordination scheme with directional over current relays is developed. In addition, impact of optimally placed Distribution Generation (DG) on the protection coordination scheme is subsequently evaluated using relay Coordination Time Interval (CTI). As such, the study is carried out in two stages. In the first stage, optimal relays settings (time dial settings and pickup current) are determined. While in the second stage, the maximum DG penetration level with changes in the protection coordination is evaluated. Particle Swarm Optimization
APA, Harvard, Vancouver, ISO, and other styles
41

Alhamrouni, Ibrahim, Rasyid Ismail, Mohamed Salem, Bazilah Ismail, Awang Jusoh, and Tole Sutikno. "Integration of STATCOM and ESS for power system stability improvement." International Journal of Power Electronics and Drive Systems (IJPEDS) 11, no. 2 (2020): 859. http://dx.doi.org/10.11591/ijpeds.v11.i2.pp859-869.

Full text
Abstract:
The power system enters a state of voltage instability due to the inability of the power system to meet the demand for active power and reactive power due to the increase of system load. In order to stabilize the power system, the installation of STATCOM and ESS needs to be performed. The main objective of this study is to identify the suitable size and location of STATCOM and ESS for power system stability improvement. First, the IEEE 14 bus system was simulated using DIgSILENT software in ideal condition. Then, the system loadability was increased up to 200% of initial value to locate the we
APA, Harvard, Vancouver, ISO, and other styles
42

de Albuquerque, Felipe Proença, Rafael Nascimento, Carlos A. Prete, and Eduardo Coelho Marques da Costa. "Phasor Measurement Unit-Driven Estimation of Transmission Line Parameters Using Variable Noise Model." Energies 17, no. 14 (2024): 3587. http://dx.doi.org/10.3390/en17143587.

Full text
Abstract:
Accurate parameters are crucial in modern energy systems to ensure the reliable operation of all components. Given the substantial volume of data in monitored systems, high-performance methods are necessary. This paper proposes a new Bayesian multi-output regressor for estimating the parameters of a three-phase transmission line. The presented approach achieves acceptable accuracy in parameter estimation using only one end of the line. The Bayesian regressor is developed using information derived from the data themselves, eliminating the need to explicitly model the system. This capability all
APA, Harvard, Vancouver, ISO, and other styles
43

Deepa, SN, and J. Rizwana. "Minimization of losses and FACTS installation cost using proposed differential gravitational search algorithm optimization technique." Journal of Vibration and Control 23, no. 2 (2016): 235–51. http://dx.doi.org/10.1177/1077546315576612.

Full text
Abstract:
The optimal location of Flexible AC Transmission Systems (FACTS) controllers in a multi-machine power system using proposed differential gravitational search algorithm (DGSA) optimization method is proposed in this paper. The main objective of this paper is to employ DGSA optimization technique to solve optimal power flow problem in the presence of Unified Power Flow controller for improving voltage profile by reducing losses along with the installation cost thereby enhancing the power system stability. A differential operator is incorporated into the gravitational search algorithm for effecti
APA, Harvard, Vancouver, ISO, and other styles
44

Sasikala, Dr K., Dr J. Jayakumar, Dr A. Senthil Kumar, Dr Shanty Chacko, and Dr Hephzibah Jose Queen. "Regression Based Predictive Machine Learning Model for Pervasive Data Analysis in Power Systems." International Journal of Electrical and Electronics Research 10, no. 3 (2022): 550–56. http://dx.doi.org/10.37391/ijeer.100324.

Full text
Abstract:
The main aim of this paper is to highlight the benefits of Machine Learning in the power system applications. The regression-based machine learning model is used in this paper for predicting the power system analysis and Economic analysis results. In this paper, Predictive ML models for two modified IEEE 14-bus and IEEE-30 bus systems, integrated with renewable energy sources and reactive power compensative devices are proposed and developed with features that include an hour of the day, solar irradiation, wind velocity, dynamic grid price, and system load. An hour-wise input database for the
APA, Harvard, Vancouver, ISO, and other styles
45

Soban, Soban, R. Sireesha, BP .., Pavithra G., and Soban Badonia. "Grey Wolf Optimizer Algorithm for Multi-Objective Optimal Power Flow." Journal of Intelligent Systems and Internet of Things 12, no. 1 (2024): 20–32. http://dx.doi.org/10.54216/jisiot.120102.

Full text
Abstract:
This article introduces the Grey Wolf Optimizer (GWO) algorithm, a novel method aimed at tackling the challenges posed by the multi-objective Optimal Power Flow (OPF) problem. Drawing inspiration from the foraging behavior of grey wolves, GWO stands apart from traditional approaches by enhancing initial solutions without relying on gradient data collection from the objective function. In the domain of power system optimization, the OPF problem is widely acknowledged, involving constraints related to generator parameters, valve-point loading, reactive power, and active power. The proposed GWO t
APA, Harvard, Vancouver, ISO, and other styles
46

Meddeb, Asma, Nesrine Amor, Mohamed Abbes, and Souad Chebbi. "A Novel Approach Based on Crow Search Algorithm for Solving Reactive Power Dispatch Problem." Energies 11, no. 12 (2018): 3321. http://dx.doi.org/10.3390/en11123321.

Full text
Abstract:
This paper presents a novel meta-heuristic approach based on the crow search algorithm (CSA) for solving the optimal reactive power dispatch (ORPD) problem. The ORPD is formulated as a nonlinear optimization problem designed to minimize power losses while satisfying the required constraints. The CSA is a recent efficient approach that depends on the intelligent behavior of crows. Nowadays, it has been used to solve many complex engineering optimization problems where it has proven its power and effectiveness. Motivated by the high ability in solving complex optimization problems and faster con
APA, Harvard, Vancouver, ISO, and other styles
47

Che Mat Haris, Harizan, Ismail Musirin, and Mohamad Fadhil Mohd Kamal. "Maximum Loadability Identification Using Self-Tuning Algorithm Considering Voltage Limit." Applied Mechanics and Materials 785 (August 2015): 393–97. http://dx.doi.org/10.4028/www.scientific.net/amm.785.393.

Full text
Abstract:
Due to the complexity of power system nowadays, voltage limit has become a concerned issue. This phenomenon attracted numerous studies in finding the ultimate solution. This paper presents the development of self-tuning technique for identifying maximum loadability for selected buses in a power system network. The algorithm is able to perform fast process in consideration of the voltage limit between 0.9 p.u. to 1.05 p.u. as the acceptable voltage limit in power system community. The proposed concept is conducted for single and multi-load increment; executed on IEEE 14-Bus RTS and IEEE 26-Bus
APA, Harvard, Vancouver, ISO, and other styles
48

Giri, Jayprakash, Sh Rajiv Chauhan, and Smt Nidhi Mishra. "Performance Study on IEEE Bus System for Contingency Problem and Mitigation." SMART MOVES JOURNAL IJOSCIENCE 7, no. 3 (2021): 49–57. http://dx.doi.org/10.24113/ijoscience.v7i3.382.

Full text
Abstract:
The increasing dependence of most businesses on electricity requires regular improvements in distribution systems. The main objective of this study is to provide load balancing in the distribution network by reducing the loss of system performance without violating the voltage and current limits of the power supplies. And the selection of the power system contingency by calculating the transmission line failure performance indices using the load flow analysis on the IEEE 14 bus system. To determine and tabulate the voltage on each bus, the actual current flow on each line and power system leak
APA, Harvard, Vancouver, ISO, and other styles
49

Rohit, Babu, and Bhattacharyya Biplab. "Optimal placement of PMU for complete observability of the interconnected power network considering zero-injection bus: A numerical approach." International Journal of Applied Power Engineering 9, no. 2 (2020): 135~146. https://doi.org/10.5281/zenodo.7349686.

Full text
Abstract:
This paper presents an approach to place the phasor measurement unit (PMU) optimally, which minimizes the setup cost of PMU. This methodology attains complete state estimation of the interconnected power networks. An integer linear programming (ILP) method is explored for the optimal PMU placement problem. It is used to determine the optimal location and minimum number of PMUs necessary to make the interconnected power network completely observable. ILP may provide many solutions if acquainting buses to zero injection buses are unhandled. In the case of more than one solution, a bus observabil
APA, Harvard, Vancouver, ISO, and other styles
50

Ahmad, Fateh Mohamad Nor, and Sulaiman Marizan. "Voltage instability analysis based on modal analysis technique and artificial neural network." Indonesian Journal of Electrical Engineering and Computer Science 13, no. 3 (2019): 1274–79. https://doi.org/10.11591/ijeecs.v13.i3.pp1274-1279.

Full text
Abstract:
One of the paramount importance in the operation of electrical power system operation order to sustain the equilibrium of the system is the stability of the load buses&rsquo; voltages. If the load buses voltages are not stable, this can cause serious problem especially power system blackout. This paper presents the analysis of voltage instability in electric power system by using modal analysis technique. However, one of the challenges of modal analysis is the intencive and complex calculation procedures. In order to overcome that, this paper implements Artificial Neural Network (ANN) to impro
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!