Academic literature on the topic 'Insertion-extraction'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Insertion-extraction.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Journal articles on the topic "Insertion-extraction"
Wang, Zhaoxiang, Xuejie Huang, and Liquan Chen. "Lithium insertion/extraction in pyrolyzed phenolic resin." Journal of Power Sources 81-82 (September 1999): 328–34. http://dx.doi.org/10.1016/s0378-7753(99)00262-1.
Full textTsumura, T. "Lithium insertion/extraction reaction on crystalline MoO3." Solid State Ionics 104, no. 3-4 (December 11, 1997): 183–89. http://dx.doi.org/10.1016/s0167-2738(97)00418-9.
Full textLi, Jiaxin, Chuxin Wu, and Lunhui Guan. "Lithium Insertion/Extraction Properties of Nanocarbon Materials." Journal of Physical Chemistry C 113, no. 42 (September 29, 2009): 18431–35. http://dx.doi.org/10.1021/jp9061658.
Full textNytén, Anton, Saeed Kamali, Lennart Häggström, Torbjörn Gustafsson, and John O. Thomas. "The lithium extraction/insertion mechanism in Li2FeSiO4." J. Mater. Chem. 16, no. 23 (2006): 2266–72. http://dx.doi.org/10.1039/b601184e.
Full textde Picciotto, La, and MM Thackeray. "Insertion/extraction reactions of lithium with LiV2O4." Materials Research Bulletin 20, no. 12 (December 1985): 1409–20. http://dx.doi.org/10.1016/0025-5408(85)90158-8.
Full textOtake, Hiroki, Yoko Sato, Eiji Nakatani, Philip Hawke, Shingo Takei, Akihiko Ogino, Hideaki Asai, Atsushi Abe, Kohta Fukuta, and Moriyasu Adachi. "Oxytetracycline-hydrocortisone ointment reduces the occurrence of both dry socket and post-extraction pain after third molar extraction: An observational study." PLOS ONE 16, no. 7 (July 2, 2021): e0254221. http://dx.doi.org/10.1371/journal.pone.0254221.
Full textKim, Sung-Hu, Ju-Won Lee, Joo-Ho Kim, Han-Wook Lee, Won-Geun Jung, and Gun-Ki Lee. "Insertion Path Extraction of Catheter for Coronary Angiography." Journal of the Korean Institute of Information and Communication Engineering 15, no. 4 (April 30, 2011): 951–56. http://dx.doi.org/10.6109/jkiice.2011.15.4.951.
Full textTsumura, T. "Lithium extraction/insertion from LiMn2O4 — effect of crystallinity." Solid State Ionics 90, no. 1-4 (September 1996): 197–200. http://dx.doi.org/10.1016/s0167-2738(96)00404-3.
Full textGu, Zonglin, Zaixing Yang, Binquan Luan, Xifa Zhou, Linbi Hong, Hong Zhou, Judong Luo, and Ruhong Zhou. "Membrane Insertion and Phospholipids Extraction by Graphyne Nanosheets." Journal of Physical Chemistry C 121, no. 4 (January 23, 2017): 2444–50. http://dx.doi.org/10.1021/acs.jpcc.6b10548.
Full textKawakita, Jin, Takashi Miura, and Tomiya Kishi. "Lithium insertion and extraction kinetics of Li1+xV3O8." Journal of Power Sources 83, no. 1-2 (October 1999): 79–83. http://dx.doi.org/10.1016/s0378-7753(99)00270-0.
Full textDissertations / Theses on the topic "Insertion-extraction"
Scott, Jeff E. "Vibratory insertion and extraction of surgical implants." Online access for everyone, 2006. http://www.dissertations.wsu.edu/Thesis/Fall2006/j_scott_120406.pdf.
Full textLaird, Daniel T. "Voice Encode/Decode System for PCM Insertion and Extraction." International Foundation for Telemetering, 1994. http://hdl.handle.net/10150/611660.
Full textIn the field of aircraft testing the need to efficiently record the cockpit voice communication without consuming a significant amount of the acquisition frame bandwidth has been an issue for years. There are methods, based on commercially available products, that allow for voice placement into PCM streams that will satisfy the requirement of relatively low bandwidth consumption. In this paper I will discuss a design that makes minimal demand on bandwidth, with the freedom to vary the placement of the voice within the minor acquisition frame.
Hamdi, Rachid. "Filtres en polarisation dédiés aux applications insertion/extraction optiques reconfigurables." Evry, Institut national des télécommunications, 2008. http://www.theses.fr/2008TELE0008.
Full textMechin, David. "Etude et réalisation de multiplexeurs insertion-extraction à réseaux de Bragg." Phd thesis, Université Jean Monnet - Saint-Etienne, 2001. http://tel.archives-ouvertes.fr/tel-00287814.
Full textNedjari, Tayeb. "Réseaux de neurones artificiels et connaissances symboliques : insertion, raffinement et extraction." Paris 13, 1998. http://www.theses.fr/1998PA132024.
Full textBorden, Michael J. "Modification of All-Hexadedral Finite Element Meshes by Dual Sheet Insertion and Extraction." BYU ScholarsArchive, 2002. https://scholarsarchive.byu.edu/etd/3449.
Full textBertoldi, Odile. "Etude et réalisation d'un multiplexeur à insertion-extraction de longueur d'ondes en optique intégrée sur verre." Grenoble INPG, 2005. http://www.theses.fr/2005INPG0153.
Full textLn the last few years, the development of telecommunications has led to an increase of informations rate. To solve this problem wavelength multiplexing possible in optic seems to be a good solution: it allows the simultaneous transmission in a same fibre of several signais of different wavelengths. The solution chosen here use ion exchange on glass substrate and combine a Mach Zehnder interferometer realised with buried waveguides and a diffraction grating etched upon surface waveguides. Before the realisation of the global component, we have developed a particular process of ion-exchange: selectively buried waveguides. It allows to realise 3 dimensional waveguides namely waveguides with some parts buried inside the glass substrate and some parts at the surface of the glass substrate. The process we developed allows to realise waveguides with a burying depth difference of 10 μm unless the transition between the buried parts and the surface parts creates excess losses or change the polarisation. This corresponds to the simulations. Then, we have checked the validity of the fabrication process of etched diffraction gratings at the surface of a glass substrate: we have realised Bragg Filters by the association of a selectively buried waveguides upon which a grating has been etched. We obtained filters with a rejection rate of 21 dB and a rejection band width of 0,45 nm. Finally, we have realised the global component, association couplers made by ion exchange in glass and the previously described Bragg filters. This assembly led to the realisation of a drop filter with a rejection rate close to 30 dB and a rejection band of 0,45 nm around 1548 nm
Bitauld, David. "Association d'un réseau de diffraction à un réseau de Bragg intracavité pour le filtrage optique accordable." Paris 11, 2005. http://www.theses.fr/2005PA112259.
Full textThe constant growth of the needs in data transmission rates has led to the development of wavelength division multiplexing (WDM). The demultiplexing associated with WDM requires very selective filters with fast tuning possibilities. In this thesis, we propose a filtering technique associating a diffraction grating with an intracavity Bragg grating. Two filters have been implemented experimentally using this principle: one using a liquid crystal intracavity grating and one using an acousto-optic Bragg grating. The liquid crystal device has a bandwidth of 0. 09nm, which is very interesting but this technique does not allow to tune the filter. A tunable Bragg grating can be implemented using the acousto-optic effect. The device we made using an acousto-optic cell has a bandwidth of 0. 076nm with a signal to noise ratio of 20dB. This filter is tunable on a range of 2. 2nm, which allows to separate 30 wavelengths. The bandwidth and the tuning range can be easily adapted by changing the diffraction grating's orientation or its period. A numerical simulation of the response of the filter for a gaussian beam has been developped and it fits the experimental results. It allows us to calculate the performances that could be obtained with filters designed differently. For example, replacing our acoust-optic cell by one with a wider active medium (commercially available) would allow us to separate 500 frequencies. It would then be possible to have a tuning range of 100nm with a bandwidth of 0. 2nm
Olivier, Ségolène. "Nouvelles structures miniatures dans des cristaux photoniques bidimensionnels planaires pour les fonctions de l'optique intégrée." Paris 6, 2002. http://www.theses.fr/2002PA066454.
Full textSahlabadi, Mohammad. "A NOVEL BIOINSPIRED DESIGN FOR SURGICAL NEEDLES TO REDUCE TISSUE DAMAGE IN INTERVENTIONAL PROCEDURES." Diss., Temple University Libraries, 2018. http://cdm16002.contentdm.oclc.org/cdm/ref/collection/p245801coll10/id/508489.
Full textPh.D.
The needle-based procedures are usually considered minimally invasive. However, in insertion into soft tissues such as brain and liver, the tissue damage caused by needle insertion can be very significant. From the literature, it has been known that reduction in needle insertion and extraction forces as well as tissue deformation during the insertion results in less invasive procedure. This work aims to design and develop a new bioinspired design for surgical needles which reduce the insertion and extraction forces of the needle, and its damage to the tissue. Barbs in honeybee stinger decrease its insertion force significantly. Inspired by that finding, a new honeybee-inspired needle was designed and developed, and its insertion mechanics was studied. To study the insertion mechanics of honeybee-inspired needle, insertion tests into artificial and biological tissues were performed using both honeybee-inspired and conventional needles. The barb design parameters effects on needle forces were studied through multiple insertion and extraction tests into PVC gels. The design parameters values of the barbs were experimentally modified to further reduce the ultimate insertion and extraction forces of the needle. Bioinspired needle with modified barb design parameters values reduces the insertion force by 35%, and the extraction force by 20%. To show the relevance, the insertion tests into bovine liver and brain tissue were performed. Our results show that there was a 10-25% decrease in the insertion force for insertions into bovine brain, and a 35-45% reduction in the insertion force for insertions into the bovine liver using the proposed bioinspired needles. The bioinspired and conventional needles were manufactured in different scales and then used to study the size scale effect on our results. To do so, the insertion tests into tissue-mimicking PVC gels and liver tissues were performed. The results obtained for different sizes of the needle showed 25-46% decrease in the insertion force. The tissue deformations study was conducted to measure tissue deformation during the insertion using digital image correlation. The tissue deformation results showed 17% decrease in tissue deformation using barbed needles. A histological study was performed to accurately measure the damage caused by needle insertion. Our results showed 33% less tissue damage using bioinspired needles. The results of the histological study are in agreement with our hypothesis that reducing needle forces and tissue deformation lead to less invasive percutaneous procedures.
Temple University--Theses
Books on the topic "Insertion-extraction"
Corps, United States Marine, ed. Helicopter insertion/extraction. [Washington, DC]: U.S. Marine Corps, 1992.
Find full textAgarwal, Anil, Neil Borley, and Greg McLatchie. Oral and maxillofacial surgery. Oxford University Press, 2017. http://dx.doi.org/10.1093/med/9780199608911.003.0015.
Full textBook chapters on the topic "Insertion-extraction"
Kiziak, Tanja. "Long extraction or parenthetical insertion? Evidence from judgement studies." In Linguistik Aktuell/Linguistics Today, 121–44. Amsterdam: John Benjamins Publishing Company, 2007. http://dx.doi.org/10.1075/la.106.08kiz.
Full textCappetti, Nicola, Carmen Brancaccio, Francesca De Sio, and Carlotta Fontana. "A Novel Procedure to Design a Positionable and Stable Drilling Template for Spine Surgery." In Lecture Notes in Mechanical Engineering, 200–205. Cham: Springer International Publishing, 2021. http://dx.doi.org/10.1007/978-3-030-70566-4_32.
Full textPercy, Andrew J., and Christoph H. Borchers. "Detailed Method for Performing the ExSTA Approach in Quantitative Bottom-Up Plasma." In Methods in Molecular Biology, 353–84. New York, NY: Springer US, 2021. http://dx.doi.org/10.1007/978-1-0716-1024-4_25.
Full textSchoenfeld, Mark H. "Pacemaker Insertion, Revision, and Extraction." In Electrophysiological Disorders of the Heart, 417–27. Elsevier, 2012. http://dx.doi.org/10.1016/b978-1-4377-0285-9.00034-x.
Full textSCHOENFELD, M. "Pacemaker Insertion, Revision, Extraction, and Follow-Up." In Electrophysiological Disorders of the Heart, 767–807. Elsevier, 2005. http://dx.doi.org/10.1016/b978-0-443-06570-5.50045-9.
Full textKawachi, Y., I. Mogi, H. Kanoh, Κ. Ooi, and S. Ozeki. "Magnetic effects on Li+ extraction/insertion reactions in spinel-type manganese oxides." In Studies in Surface Science and Catalysis, 917–20. Elsevier, 2001. http://dx.doi.org/10.1016/s0167-2991(01)82236-9.
Full textDatta, Debasish. "Optical Packet and Burst-Switched Networks." In Optical Networks, 575–94. Oxford University Press, 2021. http://dx.doi.org/10.1093/oso/9780198834229.003.0015.
Full textPiovanetti, Omar. "Tube Misdirection and Inadequate Tube Length." In Complications of Glaucoma Surgery. Oxford University Press, 2013. http://dx.doi.org/10.1093/oso/9780195382365.003.0050.
Full textBegam, K. M., M. S. Michael, and S. R. S. Prabaharan. "TOPOTACTIC LITHIUM INSERTION/EXTRACTION PROPERTIES OF A NEW POLYANION MATERIAL2(4)3[0 ≤ < 3] FOR RECHARGEABLE LITHIUM BATTERIES." In Solid State Ionics, 461–68. WORLD SCIENTIFIC, 2004. http://dx.doi.org/10.1142/9789812702586_0049.
Full textAlpuim, Ana, Marisa Esteves, Sónia Pereira, and Manuel Filipe Santos. "Monitoring Time Consumption in Complementary Diagnostic and Therapeutic Procedure Requests." In Applying Business Intelligence to Clinical and Healthcare Organizations, 208–40. IGI Global, 2016. http://dx.doi.org/10.4018/978-1-4666-9882-6.ch011.
Full textConference papers on the topic "Insertion-extraction"
Weiss, Andreas, Vasilios Andrikopoulos, Michael Hahn, and Dimka Karastoyanova. "Enabling the Extraction and Insertion of Reusable Choreography Fragments." In 2015 IEEE International Conference on Web Services (ICWS). IEEE, 2015. http://dx.doi.org/10.1109/icws.2015.96.
Full textMcGarry, K. J. "Knowledge extraction and insertion from radial basis function networks." In IEE Colloquium on Applied Statistical Pattern Recognition. IEE, 1999. http://dx.doi.org/10.1049/ic:19990372.
Full textSu, Xiaojing, Pengzheng Gao, Yayi Wei, and Weijie Shi. "SRAF rule extraction and insertion based on inverse lithography technology." In Optical Microlithography XXXII, edited by Jongwook Kye and Soichi Owa. SPIE, 2019. http://dx.doi.org/10.1117/12.2511914.
Full textLee, Seung Mi. "Hydrogen insertion and extraction mechanism in single-walled carbon nanotubes." In NANONETWORK MATERIALS: Fullerenes, Nanotubes, and Related Systems. AIP, 2001. http://dx.doi.org/10.1063/1.1420068.
Full textWang, Jianguo, Wenxing Zhang, Bo Qin, and Wei Shi. "Research on Rules Extraction from Neural Network based on Linear Insertion." In 2010 WASE International Conference on Information Engineering (ICIE 2010). IEEE, 2010. http://dx.doi.org/10.1109/icie.2010.103.
Full textJin, Yanxia, Rong Zhu, Xin Qi, Jinrui Zhang, Qifu Cheng, Bo Ma, and Yao Jia. "An Image Watermark Insertion and Extraction Method Based on EDA-PSO." In Proceedings of the 2019 2nd International Conference on Sustainable Energy, Environment and Information Engineering (SEEIE 2019). Paris, France: Atlantis Press, 2019. http://dx.doi.org/10.2991/seeie-19.2019.58.
Full textFurcas, Paola, Rosanna Pastorelli, Giulia Salmini, and Massimo Vanzi. "High Power Testing of Optical Connectors." In ISTFA 2002. ASM International, 2002. http://dx.doi.org/10.31399/asm.cp.istfa2002p0439.
Full textMcNelly, Brendan P., Robert Leary, Sean Brennan, and Karl Reichard. "Characterizing Successful Robotic Insertion and Removal From a Dry Storage Cask Using Peg-Like Jamming and Wedging Analysis." In ASME 2016 Pressure Vessels and Piping Conference. American Society of Mechanical Engineers, 2016. http://dx.doi.org/10.1115/pvp2016-63634.
Full textYang, Bo, and Hiroshi Murata. "A finite element-domain decomposition coupled resistance extraction method with virtual terminal insertion." In 2007 Joint 50th IEEE International Midwest Symposium on Circuits and Systems (MWSCAS) and the IEEE Northeast Workshop on Circuits and Systems (NEWCAS 2007). IEEE, 2007. http://dx.doi.org/10.1109/mwscas.2007.4488812.
Full textKaľavský, Peter, Róbert Rozenberg, Pavol Petríček, Vladimír Socha, and Luboš Socha. "Rope procedures for extraction and insertion of persons used by helicopter emergency medical service." In 13th Research and Education in Aircraft Design. Brno: Fakulta strojniho inzenyrstvi VUT v Brne, 2019. http://dx.doi.org/10.13164/conf.read.2018.8.
Full textReports on the topic "Insertion-extraction"
Ketner, Natalie. Rapid Sample Insertion/Extraction Systems for Gamma Irradiation. Office of Scientific and Technical Information (OSTI), August 2018. http://dx.doi.org/10.2172/1734488.
Full textKetner, Natalie. Rapid Sample Insertion/Extraction Systems for Gamma Irradiation. Office of Scientific and Technical Information (OSTI), August 2018. http://dx.doi.org/10.2172/1734489.
Full text