To see the other types of publications on this topic, follow the link: Intégrité des membranes à osmose inverse.

Dissertations / Theses on the topic 'Intégrité des membranes à osmose inverse'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 22 dissertations / theses for your research on the topic 'Intégrité des membranes à osmose inverse.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

Pype, Marie-Laure. "Monitoring reverse osmosis membrane integrity and virus rejection in water reuse." Thesis, Montpellier 2, 2013. http://www.theses.fr/2013MON20234/document.

Full text
Abstract:
Les procédés d'osmose inverse (OI) permettent la production d'eau recyclée de très haute qualité grâce à l'élimination de contaminants organiques et inorganiques et de micro-organismes. Le suivi du bon fonctionnement de ce procédé est nécessaire pour valider la rétention des virus pathogènes afin de protéger la santé des usagers. La présence de minéraux et matières organiques dans les effluents rend inévitable le colmatage des membranes lors de leur fonctionnement et diminue ainsi leur performance. Afin d'éviter et d'éliminer ces colmatages, les stations de traitements des eaux utilisent des produits chimiques. Ces derniers vont modifier les performances globales des membranes en polyamide comme par exemple la diminution de la perméabilité à l'eau, et plus particulièrement les performances de rétention des virus, or l'ensemble de ces perturbations n'est que très peu compris et donc peu maitrisé. L'abattement des virus par l'OI sur des membranes intègres ou modifiées (ex : colmatage) ont donc été déterminés en mesurant la rétention d'un virus modèle de type phage MS2 et de substituts comme les sels (mesurés par conductivité), la rhodamine-WT (R-WT) ou les sulfates. La conductivité est, en effet, la technique de contrôle standard dans les stations de traitement des eaux (échelle industrielle).Le premier objectif de ce travail est d'évaluer l'utilisation d'un autre paramètre, les matières organiques dissoutes (DOM) comme nouveau substitut de virus et de déterminer l'impact du dysfonctionnement des procédés d'OI sur l'abattement des DOM et des sels à l'échelle industrielle. Les DOM peuvent en effet également être utilisées comme indicateur de qualité des eaux en fonction de leurs compositions et de leurs concentrations. L'abattement des DOM est donc testé comme nouvelle technique de surveillance afin de distinguer les fuites des changements de performance des membranes. Il est conclu que les DOM peuvent être utilisées comme nouvelle technique de contrôle. De plus, une variation de l'abattement des DOM peut aider à identifier des fuites de manière plus robuste que par l'abattement des sels. Le deuxième objectif est de déterminer l'effet des défauts membranaires sur les abattements d'un virus modèle (phage MS2) et de quatre substituts (R-WT, DOM, sulfate et sels) à l'échelle de systèmes de laboratoire. Deux systèmes à flux longitudinal est utilisés : une membrane plane et un module à spirale. Dans un premier temps, l'effet du colmatage sur les abattements de ces différents virus et substituts est étudié. Le colmatage organique, créé en utilisant un mélange de matières organiques, a pour effet d'augmenter de plus de 0,1 log les abattements de la R-WT, des sels et des DOM. Cette augmentation générale peut être due au blocage des cavités de la membrane et/ou par la sorption des substituts sur les matières organiques.Le colmatage inorganique, créé en utilisant un mélange de sels, n'a pas d'effet sur le rejet des substituts sauf pour les sels qui montre un comportement différent entre les deux systèmes. Dans le système à membrane plane, la couche inorganique permet d'augmenter le passage des sels à travers la membrane. Par opposition, il n'y a pas d'effet sur leur abattement avec le module à spirale. Cette variation entre les deux systèmes peut être causée par la différence de configuration (module à spirale contre membrane plane). Dans un deuxième temps, l'effet du chlore (modes passif et actif) sur la rétention de ces cinq composés est mesuré. Après un contact de 9000 ppm.h de NaOCl à pH 7, la surface membranaire change chimiquement. La formation de liaison Cl dans la couche en polyamide et la rupture des liaisons NH provoquent l'augmentation de la perméabilité à l'eau et diminuent l'abattement de l'ensemble des substituts. Malgré une forte diminution de 1,2 log de l'abattement en sel, l'abattement minimum du phage MS2 reste de 3 log<br>One of the major applications of reverse osmosis (RO) process is the production of high quality recycled water by providing a barrier to remove organic and inorganic contaminants as well as pathogens including viruses. In order to protect public health, validation and monitoring of the RO process integrity are necessary to ensure its correct operation. During operation a certain degree of fouling is inevitable and can reduce RO membrane performance. Thus, chemicals are often used in water treatment plants to prevent or remove the membrane fouling. However, these chemicals can modify the integrity of the polyamide layer on RO membrane overtime. Up-to-date, the impact of membrane's physical change on its virus removal efficiency cause by the chemical use during operation is still not well understood.A minimum virus removal efficiency of intact and impaired (e.g. by fouling) RO membranes can be ascertained by measuring the rejection of MS2 phage and virus surrogates such as salt as measured by conductivity, rhodamine-WT (R-WT) or sulphate. However, conductivity measurement is the only full-scale standard monitoring technique. The removal of dissolved organic matter (DOM), which has been used as an indicator of water quality, can possibly be used for this purpose.The first objective of this work was to assess the suitability of DOM as a virus surrogate and to determine the impact of process failure on salt and DOM rejection in full-scale plants. A change of the conductivity does not necessarily mean that the membrane integrity has been breached. Thus, DOM monitoring has been tested and combined with the conductivity monitoring in order to distinguish between leaks and changes in membrane performances. It was concluded that DOM could be used as new monitoring technique. Moreover, a variation of DOM rejection can help identifying leaks better than just conductivity profiling alone.The second objective was to determine the effect of membrane impairments on the rejection of one model virus (MS2 phage) and four virus surrogates (R-WT, DOM, sulphate and salt) using lab-scale RO set-ups. To this aim, two different cross-flow set-ups were used: a flat-sheet and a single 2.5” spiral-wound module.Firstly, the effects of organic fouling and scaling on the rejection of model virus and virus surrogates were studied separately. Organic fouling was created using a mix of organic foulants. The result of this study showed an increase of the rejection by more than 0.1 log for R-WT, salt and DOM. The general increase of the surrogates' rejection might be due to the blocking of cavities of the polyamide membrane and/or to the sorption of surrogates to the fouling layer, which was observed by different autopsy techniques.Scaling was created using a mix of inorganic salts in order to reconstitute the composition of a RO feed water and avoiding the presence of organic foulants. Scaling was found to have no impact on the rejection of all tested virus surrogates except for salt. Salt rejection showed a change of behaviour between different set-ups: with the 2.5” module set-up the inorganic layer led to a stabilisation of the salt rejection, whereas the salt rejection increased with the flat-sheet set-up. This could be explained by the variations of the systems configuration (i.e. spiral module versus flat-sheet, feed spacer height, etc.).Secondly, the long-term impact of membrane ageing by exposure to chlorine, either active under filtration or passive by soaking, on the rejection of the model virus and four surrogates was studied. After a contact time of 9000 ppm∙h NaOCl at pH 7, the membrane surface chemistry changed. The introduction of chlorine in the membrane chemistry and the breakage of amide bonds caused an increase of the water permeability and a decrease of the model virus and virus surrogates rejection
APA, Harvard, Vancouver, ISO, and other styles
2

Ettori, Axel. "Vieillissement chimique de membranes d'osmose inverse." Toulouse 3, 2011. http://thesesups.ups-tlse.fr/1409/.

Full text
Abstract:
Ce travail porte sur l'étude du vieillissement chimique de membranes d’osmose inverse (OI) en présence de chlore, oxydant couramment utilisé en traitement d'eau. Une analyse multi-échelle d'une couche nanométrique de polyamide aromatique (PA) présente en surface d'une membrane OI commercialisée (SW30HRLE-400 de Dow FilmTecTM) a été réalisée. Des analyses par XPS et FTIR en ATR ont montré que les compositions élémentaire et chimique en surface et en profondeur du PA sont rapidement modifiées par chloration, une réaction de substitution électrophile réalisée en 2 temps, à des doses d'exposition au chlore actif variant de 40 à 4000 ppm. H, auxquelles les membranes OI sont susceptibles d'être exposées en exploitation. L'incorporation du chlore au sein du PA s'accompagne d'une augmentation monotone continue de la fraction de fonctions carbonyle non associées traduisant une mobilité accrue au sein du PA, mécanisme de vieillissement principal identifié dans ce travail. Ces transformations chimiques couplées à des variations de propriétés de transfert en osmose inverse déterminées à l'échelle du laboratoire mettent en évidence trois domaines d'influence de la chloration. Pour une exposition inférieure à 400 ppm. H HOCl, espèce active dans la chloration pour un pH en solution supérieur à 5,0, soit pour un ratio de 1 atome chlore incorporé pour 2 atomes d'azote (élément constitutif de la couche active), la sélectivité eau/soluté de la membrane OI est améliorée. Elle pourrait résulter d'un accroissement de la fraction et/ou de la dimension de volumes libres au sein du PA. L'amélioration des performances en osmose inverse est en revanche réalisée aux dépens de la tolérance de la membrane OI à une exposition consécutive à HOCl, comme mis en évidence par des essais de chloration séquentielle à l'échelle pilote. Au-delà de la dose d'exposition seuil, de 400 ppm. H HOCl, les performances en sélectivité en OI se détériorent et la structure du PA est irréversiblement fragilisée mécaniquement, vraisemblablement par la transition d'un état ductile à un état fragile. Enfin, le vieillissement chimique du PA semble se stabiliser pour une dose supérieure à 2000 ppm. H HOCl, soit pour un ratio de 1 atome de chlore incorporé pour 1 atome d’azote. A ces doses d'exposition, la mobilité des chaines du PA est décrite par des modifications de la perméabilité à l'eau, conditionnées par la pression appliquée et par le flux de transfert initial d'un anion<br>In this dissertation, a study on the chemical aging of reverse osmosis membranes (RO) with exposure to chlorine, an oxidant commonly used in water treatment, is presented. A multi-scale analysis was performed to investigate the chemical aging of a thin film aromatic polyamide (PA), active layer of a composite RO membrane (SW30HRLE-400, Dow FilmTecTM). XPS and ATR-FTIR analysis show that elemental and chemical composition at the surface and in the bulk of the PA nanolayer are rapidly modified during chlorination, a two-step electrophilic substitution reaction, at free chlorine doses between 40 and 4000 ppm. H, at which RO membranes are likely to be exposed to during operation. A continuous increase in the fraction of non associated carbonyl groups was observed with the incorporation of chlorine within the PA. It is believed to result in an increase in the mobility of the PA layer, main chemical aging mechanism found during this study. Three characteristic chlorine induced PA structure modifications have been identified by combining transport property variations determined during RO experiments at the lab scale and chemical transformations. At a chlorine exposure below 400 ppm. H HOCl, free chlorine active specie at a pH above 5. 0, corresponding to a bound chlorine to nitrogen (characteristic element of the PA) 1:2 ratio, water / solute selectivity of the RO membrane is improved. This phenomenon is believed to be caused by an increase in the fraction and/or size of free volumes within the PA. However, enhancement of RO membrane performance is achieved at the expense of its tolerance to subsequent exposure to HOCl, as demonstrated at the pilot scale during a study on the effects of continuous chlorination. At an exposure dose above 400 ppm. H HOCl, RO selectivity capabilities and PA layer mechanical properties are permanently impaired, likely by embrittlement. Finally, PA chemical aging seems to level off for an exposure to 2000 ppm. H HOCl, corresponding to a bound chlorine to nitrogen 1:1 ratio. In these conditions, PA chain mobility can be described by water permeability, as observed from the latter’s variations with the applied pressure and with the initial flux of an anion
APA, Harvard, Vancouver, ISO, and other styles
3

Roth, Estelle. "Détection et modélisation du vieillissement et du colmatage de membranes d'osmose inverse par traitement numérique de signaux issus de traçage par des ions : application à l'étude des membranes FT30-4040 utilisées dans la préparation d'eau ultrapure." Mulhouse, 1998. http://www.theses.fr/1998MULH0528.

Full text
Abstract:
L'étude des performances de modules d'osmose inverse spiralés FT30-4040 intégrés au procédé de traitement d'eau pour dialyse rénale des Hôpitaux de Colmar met en évidence la difficulté de caractériser l'état des membranes. Des expériences de traçage ont donc été réalisées sur ces modules. L'injection de traceur (solutions de NaCl, HCl et NaOH) étant réalisée en amont de la pompe multiétagée, la réponse impulsionnelle du pack membranaire s'obtient par déconvolution grâce au filtre de Kalman du signal expérimental par la fonction d'appareillage mesurée en court-circuitant le pack membranaire. Les premières expériences sont réalisées à faible pression pour éviter la perméation. Les distributions obtenues sont monodisperses et présentent des traînes. La modélisation en série de mélangeurs parfaits avec échange met en évidence l'existence des excursions du traceur dans la membrane. Ensuite, la pression est augmentée et la perméation a lieu. La distribution du traceur en sortie de membrane côté rejet confirme les observations précédentes. Celles obtenues côté perméat sont monodisperses pour un traçage avec des solutions de HCl et de NaCl. Pour les membranes usées, elles sont polydisperses avec apparition d'écoulements préférentiels proches de l'origine avec l'usure. Ces distributions se décomposent en une somme pondérée de distributions de type piston à dispersion axiale : chacune représentant un mode de perméation à travers la membrane. La réjection de la membrane baisse suite à la formation de ces nouveaux modes. Un modèle de connaissance à paramètres localisés distingue chaque zone d'écoulement dans le module membranaire. La membrane est représentée en une série de pistons à dispersion en parallèle. Ils permettent de définir des coefficients de dispersion axiale dans la membrane. Une baisse des capacités de réjection de la membrane s'assimile à une augmentation des coefficients de diffusion des traceurs dans la membrane.
APA, Harvard, Vancouver, ISO, and other styles
4

Vourch, Mickaël. "Traitement d'eaux de procédés de laiterie : production d'eau réutilisable par opérations à membranes." Rennes 1, 2004. http://www.theses.fr/2004REN10112.

Full text
Abstract:
Dans l'industrie laitière, les phases de démarrage, d'équilibrage et d'arrêt des installations génèrent des eaux de procédés, composées de matière laitière diluée sans produits chimiques. Les objectifs sont de traiter par membranes (nanofiltration ou osmose inverse, OI) ces fluides afin de simultanément valoriser la matière laitière concentrée et de réutiliser l'eau produite sur site. Des eaux de procédés modèles (définies par des enquêtes et des rencontres avec des industriels laitiers) et industrielles ont été concentrées; les protéines du lactosérum et le lactose forment progressivement un gel qui diminue le flux de perméat et qui limite le facteur de concentration. Les eaux obtenues par OI sont comparables (COT, Carbone Organique Total et conductivité) aux condensats d'évaporation qui sont déjà reutilisés industriellement. Un traitement de finition par OI produit une eau déminéralisée avec une teneur en COT, principalement due au lactose, conforme à la norme sur l'eau potable.
APA, Harvard, Vancouver, ISO, and other styles
5

Tansakul, Chatkaew. "Procédés hybrides à membranes pour le prétraitement d'eau de mer avant dessalement par osmose inverse." Toulouse, INSA, 2009. http://eprint.insa-toulouse.fr/archive/00000305/.

Full text
Abstract:
Ce travail s’inscrit dans une approche innovante d'intégration de différents procédés membranaires. L'objectif général est l'étude du prétraitement d'eau de mer avant dessalement par osmose inverse afin de réduire le potentiel de colmatage de l'eau vis-à-vis des membranes d'osmose. La démarche adoptée dans cette étude consiste à comparer différents procédés hybrides à membrane : la coagulation couplée à l'ultrafiltration (UF) d'une part et l'adsorption couplée à l'ultrafiltration d'autre part dans différentes conditions opératoires, et pour différents coagulants et adsorbants. Pour cela, des essais de laboratoire et à l'échelle pilote ont été conduits avec une eau de mer réelle de la Méditerranée. Quel que soit le procédé de prétraitement concerné (UF seule ou procédé hybride/UF), l'effet de la qualité du perméat obtenu sur les performances d'une membrane d'osmose ne permet pas de discriminer les procédés. Des taux de rétention en sels élevés, une faible concentration des matières organiques dans le perméat d'osmose inverse et un colmatage progressif dû au dépôt des sels et des matières organiques sont observés pour des expériences en laboratoire à l'échelle de quelques heures. La mise en oeuvre de procédés hybrides adsorption par charbon actif en poudre/UF par rapport au procédé d'UF seule a conduit à des résultats particulièrement intéressants : un faible SDI3, un taux de rétention en matières organiques élevé (70 %) et un colmatage très réduit de la membrane d'UF. De plus, l'approfondissement de l'étude de ce couplage, mis en oeuvre en cellule tangentielle, a montré qu'une augmentation de la vitesse de circulation permet encore une réduction du colmatage. Concernant les procédés hybrides de coagulation/UF, nos résultats montrent qu'ils permettent une diminution du SDI3 et une réduction importante du colmatage. Cependant, ils présentent une faible amélioration du taux de rétention (23 %) par rapport à l'UF seule<br>This thesis emphasizes on an innovative integrated approach of membrane processes. The main objective is to study the seawater pretreatment process before seawater reverse osmosis (SWRO) desalination for reducing the fouling potential of water towards RO membranes. The approach followed in this study is to compare different hybrid membrane processes: the coagulation combined with ultrafiltration (UF) and the adsorption combined with ultrafiltration, at different operating conditions and with different coagulants and adsorbents. Consequently, lab- and pilot-scale experiments were carried out with real seawater from Mediterranean Sea. The effect of permeate quality on the performance of RO membrane cannot be distinguished for lab-scale short term experiments whatever the pretreatment process (UF alone or hybrid process/UF) used. High salt retention, low organic concentration in the RO permeate and gradual fouling due to salt and organic matter deposit are observed. The hybrid process Powdered Activated Carbon adsorption/UF leads to particularly interesting results: low SDI3, high organic matter retention rate (70 %) and low UF membrane fouling. Furthermore, the study of this hybrid process carried out in cross-flow filtration showed that an increase of cross-flow velocity allows reducing more the fouling. Concerning the hybrid processes coagulation/UF, the results showed that coagulation/UF allows decreasing the SDI3, significantly reducing the fouling. Nevertheless, it performs low improvement in organic matter retention rate (23 %)
APA, Harvard, Vancouver, ISO, and other styles
6

El, Khabbaze Hatim. "Traitement de solutions modèles du lait par des membranes de nanofiltration et d’osmose inverse." Rennes 1, 2008. http://www.theses.fr/2008REN1S009.

Full text
Abstract:
Les diminutions de flux de membranes d’osmose inverse et de nanofiltration dépendent de l’augmentation de la pression osmotique et/ou du colmatage. Pour comparer leur contribution relative on introduit les pertes de flux ≜Josm et ≜Jf. Lors de la filtration de lactosérum, de lait écrémé et de solutions modèles (ultrafiltrat lait, protéines solubles) les pertes ≜Josm sont supérieures à ≜Jf (colmatage) à des pressions ≤ 15 bar lorsque le flux limite de l’osmose inverse est atteint (20-25 bar) ; en nanofiltration, le facteur est de 2 fois au minimum. De plus en mode concentration continue, en raison d’une polarisation de concentration (convection) plus forte de la membrane de nanofiltration la pression osmotique à la paroi devient supérieure à celle de l’osmose inverse. Ces éléments permettront la gestion du procédé de concentration pour éviter notamment la précipitation du lactose dans la couche limite à la paroi de la membrane<br>Flux decline of reverse osmosis and nanofiltration membranes depend on increase of osmotic pressure and/or fouling. In order to compare their relative roles, flux declines ≜Josm et ≜Jf. Were proposed. Runs with whey, skimmed milk and model solutions (milk ultrafiltrate, soluble proteins) show that flux losses ≜Josm were higher than ≜Jf (fouling) at pressures ≤ 15 bar or equal when reverse osmosis limiting flux was reached (20-25 bar) ; for nanofiltration, this ratio was 2 fold at least. Moreover, in continuous concentration mode, osmotic pressure at the nanofiltration membrane wall became higher than that of reverse osmosis due to an enhanced concentration polarisation (convection). These effects should permit a better process prediction with a prevention of lactose precipitation at the membrane wall
APA, Harvard, Vancouver, ISO, and other styles
7

Meng, Linghua. "Caractérisation et extraction par techniques séparatives membranaires de polyphenols actifs et fonctionnels de Perilla frutescens." Aix-Marseille 3, 2007. http://www.theses.fr/2007AIX30045.

Full text
Abstract:
L’extraction des polyphénols de Perilla frutescens est optimisée à l’échelle du laboratoire pour obtenir un extrait rouge riche en antioxydants. Les composés phénoliques sont identifiés par RMN ou CL-SM, dont l’acide coutarique, la lutéoline-7-O-glucuronide et la vicénine-2 sont pour la première fois identifiés chez Perilla. L’extraction, la purification et la concentration de l’extrait de Perilla en grande quantité sont réalisées à l’échelle pilote par des procédés membranaires : microfiltration tangentielle, couplée avec l’osmose inverse (OI), équipées de membranes de type industriel. Les extraits microfiltrés sont concentrés par OI et/ou évaporation, jusqu’à un facteur de réduction volumique de 117. La stabilisation des extraits anthocyaniques est réalisée par atomisation, et l’activité antioxydante (AAO) est analysée par méthode DPPH. On a comparé l’AAO et la composition en polyphénols de 10 chémovars de Perilla. La malonylshisonine et l’acide rosmarinique sont les plus actifs en AAO<br>The extraction of polyphenols of Perilla frutescens is optimized at the laboratory scale to obtain a red extract, rich in antioxidant. The extracted polyphenolics are identified by NMR and LC-MS. Coutaric acid, luteolin O-glucuronide and vicenin-2 are for the first time identified in Perilla. The extraction, the purification and the concentration of Perilla extracts in large quantity are carried out at the pilot plant scale using coupled-membrane process: cross-flow microfiltration (CFM) and reverse osmosis (RO) equipped with industrial-type membranes. The microfiltrated extracts were concentrated by RO and/or by evaporation, up to a volume reduction factor of 117. Stabilization of anthocyanin extracts was carried out by spray-drying pilot unit to preserve their antioxidant activity (AOA), determined using DPPH method. AOA and polyphenol composition of 10 Perilla chemovars were compared. Malonylshisonin and rosmarinic acid are the most active compounds amongst all phenolics extracted from Perilla samples
APA, Harvard, Vancouver, ISO, and other styles
8

Bassani-Linck, Valquiria. "Valorisation de formes galéniques végétales : désalcoolisation et concentration de solutions extractives sur membrane d'osmose inverse." Montpellier 1, 1990. http://www.theses.fr/1990MON13514.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Combernoux, Nicolas. "Traitement d'effluents nucléaires aqueux : étude de la dégradation des membranes d'osmose inverse sous irradiation gamma." Thesis, Aix-Marseille, 2015. http://www.theses.fr/2015AIXM4374.

Full text
Abstract:
L’utilisation du procédé d’osmose inverse (OI) pour le traitement d’effluents nucléaires aqueux pose la problématique des effets de radiolyse et de vieillissement des membranes sous irradiation ɣ. Les performances des membranes (perméabilité, taux de rétention en strontium et césium) après irradiation ɣ ont été étudiées. L’irradiation par une source externe (60Co) a été réalisée dans différentes conditions représentatives de situations réelles (0,1 à 1 MGy, à 0,5 et 5 kGy.h-1, présence ou absence d’eau et d’oxygène). Une démarche analytique innovante et complémentaire (FTIR-ATR, XPS, production de gaz et d’espèces hydrosolubles) a été mise en œuvre afin d’obtenir des informations pertinentes sur les effets de l’irradiation sur les matériaux constitutifs. La chute des performances, débutant entre 0,2 MGy et 0,5 MGy, en présence d’oxygène et d’eau (débit de dose 0,5 kGy.h-1), est liée à des scissions de chaînes localisées sur la couche active de la membrane. Les dégradations se sont révélées plus faibles en absence d’oxygène et d’eau et à débit de dose à élevé. Les performances des membranes ont ensuite été évaluées sur trois matrices aqueuses différentes représentant respectivement des effluents radioactifs issus de situation post-accidentelle, accidentelle ou procédé. Les essais menés à l’échelle laboratoire et pilote montrent que dans chaque cas, l’utilisation de l’OI est possible en choisissant des membranes et des conditions opératoires adaptées. Pour finir, le temps pour atteindre une valeur seuil de dose intégrée reçue par les membranes a été estimé grâce au logiciel RABBI : une dizaine de jours pour l’effluent accidentel, plusieurs années pour les deux autres cas<br>The treatment of nuclear liquid wastes by reverse osmosis (RO) involved issues of the water radiolysis and the membrane ageing due to ɣ irradiation effects. Membrane performances (permeability, strontium and cesium retention) were assessed after ɣ irradiation. Irradiation was carried out with an external 60Co source in different conditions that simulated real used of the process (dose from 0.1 to 1 MGy, dose rate of 0.5 and 5 kGy.h-1, with or without oxygen or water). Several analytical methods were performed to evaluate irradiation effects (ATR-FTIR, XPS, gas production, water soluble species released from the membrane). The methodology developed led to relevant information due to an innovative analytical protocol. Membrane performances started dropping between 0.2 and 0.5 MGy with oxygen and water (dose rate 0.5 kGy.h-1). This shift was linked to chains scissions inside the membrane active layer. The membrane degradation was weaker without oxygen or water or at high dose rate (5 kGy.h-1). Results showed that each analysis comforted each other. Membrane performances were also evaluated with three different types of liquid effluents, representing radioactive effluents from a post-disaster situation (groundwater type), disaster situation (seawater) or process water. Experiments were carried out at lab and pilote scales. Results indicated that the treatment of each effluent was possible by RO with an adequate choice of membrane and operating parameters. Finally, the time to reach an integrated dose threshold for the membrane in real conditions was estimated with the RABBI software : a dozen of days in the case of disaster situation to several years in the two other cases
APA, Harvard, Vancouver, ISO, and other styles
10

Mai, Zhaohuan. "Procédés membranaires pour le traitement de l'eau, étude et modélisation des interctions entre membranes et composés organiques." Phd thesis, Ecole Centrale Paris, 2013. http://tel.archives-ouvertes.fr/tel-00969165.

Full text
Abstract:
L'objectif de cette thèse est de mettre en évidence le comportement à l'échelle microscopique des composés organiques au cours des procédés de traitement de mélanges complexes, en particulier les procédés membranaires. Pour cela des outils expérimentaux et de modélisation ont été mis au point. Les méthodes de caractérisation expérimentale des mélanges complexes et de l'état de surface des solides utilisés sont entre autres la construction d'isothermes d'adsorption et la mesure des tensions interfaciales par la méthode de la goutte posée. Le cas étudié ici est celui de la filtration de solutions modèles de tensioactifs par osmose inverse. Nous avons montré que le comportement des composés organiques (tensioactifs) influence la performance du procédé membranaire et les propriétés de membranes. L'outil de simulation du comportement des composés en phase liquide et à l'interface liquide-solide permettant une description à une échelle plus fine que celle atteignable expérimentalement est la DPD (Dissipative Particle Dynamics). Une première étape a permis de simuler l'agrégation des tensioactifs en solution et de retrouver les valeurs expérimentales des concentrations micellaires critiques et nombres d'agrégation de tensioactifs anioniques. L'étude de l'adsorption des tensioactifs sur une membrane d'osmose inverse a été initiée, avec pour objectif de mettre en évidence l'organisation des composés à l'échelle locale. L'apport des outils développés a été démontré et leur utilisation pourra être approfondie dans des travaux ultérieurs.
APA, Harvard, Vancouver, ISO, and other styles
11

Mondamert, Leslie. "Seawater desalination, autopsy and cleaning of reverse osmosis membranes recovered from full-scale plants and pilot units." Poitiers, 2010. http://www.theses.fr/2010POIT2264.

Full text
APA, Harvard, Vancouver, ISO, and other styles
12

Menjeaud, Christiane. "Etude des conditions de formation "in situ" d'une membrane d'osmose inverse sur un support poreux en acier inoxydable et caractérisation." Montpellier 2, 1989. http://www.theses.fr/1989MON20213.

Full text
Abstract:
En osmose inverse la separation des solutes est regie par des mecanismes de solubilisation-diffusion. L'importance des affinites chimiques des trois constituants (solvant, solute, membrane) est telle, qu'une membrane d'osmose inverse donnee peut presenter un debit de permeat et un taux de retention differents, selon la solution a traiter. D'ou l'idee d'une membrane d'osmose inverse formee in situ, specifique, adaptable, deposee sur un support poreux standard. Cette membrane, si elle est destructible pourra etre redeposee a volonte. Ce dernier point ayant l'avantage de minimiser les pretraitements, de pouvoir deposer plusieurs types de membrane avec un meme appareillage tout en adaptant le procede a la solution a traiter
APA, Harvard, Vancouver, ISO, and other styles
13

Ding, Minxia. "Molecular simulations of reverse osmosis membranes." Thesis, Rennes 1, 2015. http://www.theses.fr/2015REN1S058/document.

Full text
Abstract:
L'osmose inverse (OI) est actuellement le procédé le plus utilisé mondialement pour le dessalement des eaux saumâtres et de l’eau de mer. Cette thèse s'est intéressée à la simulation moléculaire de membranes d'OI afin d'améliorer la compréhension des propriétés structurales, dynamiques et de transport de l'eau et d'ions à l'intérieur de ces matériaux. La membrane d'OI étudiée dans ce travail est une membrane de polyamide aromatique, matériau le plus utilisé actuellement en OI. Dans la première partie de ce travail, une méthodologie a été développée pour construire un modèle atomique en trois dimensions d'une membrane polyamide fortement réticulé. Des simulations de dynamique moléculaire à l’équilibre (EMD) et hors-équilibre (NEMD) ont été réalisées pour étudier le comportement de l'eau et des ions Na+ et Cl- à travers la membrane. Les simulations EMD ont montré que les caractéristiques structurales de la membrane modèle étaient en bon accord avec celles d'une membrane typique d'OI. Les propriétés dynamiques et diélectriques de l'eau confinée dans la membrane ont également été étudiées et il a été montré que celles-ci étaient fortement modifiées par rapport à une phase volumique. Deux types de techniques NEMD ont été utilisés pour étudier le transport baromembranaire à travers la membrane modèle. La perméabilité à l'eau pure a été trouvée en très bon accord avec les données expérimentales rapportées dans la littérature et les deux méthodes NEMD ont révélé une très forte rétention saline, confirmant ainsi la pertinence du modèle de membrane d'OI développé dans ce travail<br>Reverse osmosis (RO) is currently the leading process used worldwide for both brackish and seawater desalination. This thesis focuses on the molecular simulation of RO membranes in order to improve the understanding of structure, dynamics and transport of water and ions inside these materials. The RO membrane studied in this work is a typical polyamide RO membrane. In the first step of this work, a methodology for building a fully atomic and three-dimensional model of a highly cross-linked polyamide membrane was developed. Both equilibrium molecular dynamics (EMD) and non-equilibrium molecular dynamics (NEMD) simulations were further performed to investigate the behavior of water and ions (Na+ and Cl-) through the membrane. EMD simulations showed that the structural characteristics of the model polyamide membrane were in good agreement with those of a typical RO membrane. The dynamics and dielectric properties of water confined in the RO membrane were also studied and have shown to be dramatically modified with respect to the bulk phase. Two types of NEMD techniques were employed to investigate pressure-driven transport through the model membrane. Pure water permeability was found to be in very good agreement with experimental data reported in the literature for similar membrane materials and both NEMD methods highlighted very high salt rejection properties, thus confirming the relevance of the model membrane developed in this work
APA, Harvard, Vancouver, ISO, and other styles
14

Cros, Séverine. "Concentration et dessalement de jus de cuisson de produits de la mer par des procédés à membranes en vue de la récupération d'arômes." Lorient, 2004. http://www.theses.fr/2004LORIS042.

Full text
Abstract:
Les jus de cuisson de produits de la mer sont très polluants car fortement chargés en matières organiques. Ces jus, dotés d’une bonne qualité aromatique, peuvent cependant être valorisés. L’objectif de cette thèse était de concevoir un procédé à membranes effectuant à la fois la concentration et la dépollution de ces jus et d’évaluer sa faisabilité technico-économique. La structure du procédé a été définie sur la base de la qualité aromatique des concentrés obtenus, évaluée par analyse sensorielle et par CPG-SM. Les jus sont clarifiés par filtration, puis dessalés par électrodialyse, et enfin concentrés par osmose inverse. Les performances des deux dernières étapes ont été étudiées et modélisées afin de simuler différents modes de conduite de l’installation. Les simulations ont été utilisées pour dimensionner une installation industrielle, puis estimer son coût. Les résultats montrent que le procédé retenu permet de répondre à l’objectif fixé, à un coût raisonnable<br>Seafood industries generate a great amount of cooking juices which have a high polluting load. Reducing this one is an obligatory step before the release into the environment. On the other hand, these juices contain potentially valuable aromas. The aim of this thesis was first to find a membrane process capable to both concentrate flavour compounds and remove the polluting load of these effluents and secondly to prove its economical feasibility. This process was chosen on the basis of the aroma concentrate quality obtained. It consists in a first step of clarification, then a desalination by electrodialysis and a concentration by reverse osmosis. Performances of these two last steps were evaluated to build models usable to the development of a simulator. This one was used to size and evaluate the cost of an industrial plant and to test the influence of several scenarii on the membrane surface. Results have shown that seafood industries could have an interest to install such a process
APA, Harvard, Vancouver, ISO, and other styles
15

Rapenne, Sophie. "Dessalement d'eaux de mer par osmose inverse : impact des procédés conventionnels sur les caractéristiques physicochimiques et microbiologiques de la ressource et étude du colmatage." Poitiers, 2007. http://www.theses.fr/2007POIT2353.

Full text
Abstract:
Les avancées récentes dans les technologies membranaires ont permis une large application de l’osmose inverse au dessalement d’eaux de mer. Pourtant, le fonctionnement opérationnel des usines demeure un challenge. La mise en place d’un prétraitement adapté à la qualité de l’eau d’alimentation et à ses fluctuations saisonnières est nécessaire afin de minimiser le colmatage des membranes. L’objectif de ces travaux a été d’étudier l’impact des prétraitements conventionnels et membranaires sur la qualité de l’eau. Les expériences ont été conduites à l’échelle du laboratoire avec de l’eau de l’Océan Atlantique et sur unités pilote situées sur la Mer Méditerranée et en Australie. Le prétraitement conventionnel est constitué d’une coagulation au chlorure ferrique suivie par une filtration sur filtre bicouche (sable/anthracite). L’impact de la pré ou post-chloration a aussi été étudié à l’échelle du laboratoire. Les analyses de carbone organique total (COT) et de microorganismes (bactéries hétérotrophes et cellules picophytoplanctoniques), réalisées par cytométrie en flux, ont montré une faible élimination du COT (environ 15%) et une élimination d’environ 80% des microorganismes par coagulation. Le prétraitement membranaire par UF ne permet pas d’éliminer de COT mais assure une élimination quasi totale des microorganismes. Le pouvoir colmatant en ultrafiltration ou microfiltration subit une diminution significative après prétraitement. Enfin, les tests d’osmose inverse à l’échelle du laboratoire ont prouvé la difficulté de relier la présence d’un dépôt à la surface de la membrane à une baisse tangible de ses performances hydrauliques<br>Reverse osmosis is a leading process for seawater desalination. Pre-treatment is essential in designing RO plant to ensure long-term performance of the RO membranes and minimize membrane fouling. It must be adapted to the seasonal variations of the feed water quality. The objective of our work was to study the impact of conventional and membrane pre-treatment processes on water quality. The experiments were carried out on a lab-scale unit with seawater from the Atlantic Ocean and on pilot-scale units located on the French Riviera and in Australia. The conventional treatment train consisted of Fe (Ferric chloride) coagulation followed by dual media (sand/anthracite) filtration. The impact of pre or post-chlorination was also studied at bench-scale. Several parameters were monitored both in raw and treated waters including Total Organic Carbon (TOC) and microorganisms content (picophytoplanktonic cells and bacteria), analysed by flow cytometry. The conventional pre-treatment removes only 15% or less of the TOC and 80% of the microorganisms whereas the membrane pre-treatment removes all the microorganisms but no TOC. The fouling potential measured by ultrafiltration or microfiltration is significantly reduced after pre-treatment. The reverse osmosis tests conducted at the lab scale showed the difficulty to establish a link between the deposit of foulants on the membrane and a decrease of the hydraulic performances
APA, Harvard, Vancouver, ISO, and other styles
16

Adje, Félix Anoh. "Production par procédés membranaires couplés d'extraits polyphénoliques de Carapa procera, Delonix regia et Hibiscus sabdariffa. Détermination des structures moléculaires et des activités antioxydantes." Aix-Marseille 3, 2009. http://www.theses.fr/2009AIX30054.

Full text
Abstract:
L’extraction des polyphénols de feuilles de Carapa procera, de fleurs de Delonix regia et de calices d Hibiscus sabdariffa est optimisée à l'échelle du laboratoire pour obtenir des extraits rouge riches en antioxydants. Les anthocyanes, les flavonols et les acides phénols de ces 3 plantes endémiques de Côte d'Ivoire ont été caractérisés par CL-SM et RMN pour la première fois dans les 2 premières plantes et confirmés dans la troisième. La macération 12-16h dans l' eau d échantillons séchés localement, la macération 1h avec assistance par ultrasons, la microfiltration et la concentration des extraits à l'échelle pilote a permis la production de 250L de microfiltrat/plante avec des débits moyens de 100 à 200 L. H-1. M-2. B-1 à 0,6 bar, de concentrer de 100 à 120 fois le volume de ces microflltrats à 16 et 20 L. H-1. M-2 à 40 bar et a 20° C et de produire par atomisation, avec des rendements de 5 à 10% des poudres d' extraits polyphénoliques (30 à 160 [micro]mol. G-1 AG eq), dont on a déterminé la capacité antioxydante par DPPH et ABTS (de 8 à 30 mmol. L-1 AG eq pour les concentrés d'OI et 220 à 500 mmol. G-1 TEAC pour les poudres)<br>The extraction of the polyphenols of Carapa procera leaves, of Delonix regia flowers and of Hibiscus sabdariffa calyx was optimized at laboratory scale to obtain a red extracts rich in antioxidants. Anthocyanins, flavonols and phenolic acids of these 3 endemic plants from Ivory Coast were characterized by LC-MS and NMR for the first time in the 2 first plants and confirmed in the third. Water maceration, 12-16h time, of locally dried samples, 1hour time ultrasound-assisted maceration, microfiltration and concentration of the extracts at pilot plant scale allowed the production of 250L of microfiltrate/plant processed with average MFT flows of 100 to 200 L. H-1. M-2. B-1 at 0,6 bar, the volume concentration of the microfiltrates of 100 to 120 times with 16 and 20 L. H -1. M -2 fluxes at 40 bar and at 20°C and to produce powders by atomization, with a 5 to 10 % yield, of polyphenolic extracts (30 in 160 [micro]mol. L-1 AG eq), of which the antioxidant capacity was determined by DPPH and ABTS (from 8 to 30 mmol. L-1 AG eq for RO concentrates and from 220 to 500 mmol. G-1 TEAC for powders)
APA, Harvard, Vancouver, ISO, and other styles
17

Sagne, Camille. "Etude des mécanismes de transfert de molécules organiques en osmose inverse : application au recyclage des condensats issus de la concentration des vinasses de distilleries." Phd thesis, AgroParisTech, 2008. http://tel.archives-ouvertes.fr/tel-00292725.

Full text
Abstract:
L'osmose inverse semble un procédé intéressant pour traiter les condensats de distilleries et les recycler en fermentation alcoolique. Il permettrait de retenir les molécules organiques inhibitrices de la fermentation. Cependant, les mécanismes de rétention de ces molécules sont encore mal connus et l'optimisation du procédé reste très empirique.<br />Des méthodes de chromatographies liquides et gazeuses ont été développées et/ou améliorées pour quantifier les composés inhibiteurs et un test de fermentation a été mis au point. Les membranes les plus adaptées ainsi qu'un pilote à membrane spiralée ont été sélectionnés pour réaliser l'étude. <br />Les molécules et les membranes ont été caractérisées plus finement : les premières par des descripteurs moléculaires, les secondes par mesures de potentiels zêta et d'angles de contact. Du fait de ces propriétés, le phényl-2-éthanol, l'acide butyrique et le furfural s'adsorbent fortement sur les membranes. L'acide acétique se dissout dans l'eau interstitielle.<br />Ces interactions expliquent partiellement le transfert des solutés au cours du procédé, mais d'autres phénomènes sont en jeu : la diffusion dans la membrane, la densité de flux de perméat, les compétitions entre molécules. <br />L'utilisation de la membrane ESPA2 à 10 bar, à pH naturel permet d'obtenir un perméat fermentescible jusqu'à un facteur de réduction volumique de 8.<br />Un modèle a été développé pour prendre en compte les interactions et représenter le traitement industriel. Les constantes d'adsorption sont obtenues expérimentalement tandis que le coefficient de diffusion est ajusté.
APA, Harvard, Vancouver, ISO, and other styles
18

Song, Xuefan. "Structural characterization and molecular modeling of the active aromatic polyamide layer in reverse-osmosis membranes." Thesis, université Paris-Saclay, 2020. http://www.theses.fr/2020UPASB024.

Full text
Abstract:
Les membranes d’osmose inverse (OI) sont des membranes composites, dont la couche active de surface, directement responsable des performances de rétention, est en polyamide aromatique réticulé (PAA, épaisseur ∼200 nm), polymérisé sur un support poreux en polysulfone lui-même déposé sur une couche en polyester non tissé. L’osmose inverse est un procédé de plus en plus utilisé pour le traitement des effluents industriels mais le comportement des petits solutés organiques neutres reste difficile à prédire. Ce travail combine une approche expérimentale de caractérisation structurale de ce polymère avec une approche par modélisation moléculaire, afin d’améliorer la compréhension des phénomènes à l’échelle moléculaire.Nous avons étudié une membrane commerciale (CPA2) ainsi que des films auto-supportés, synthétisés au laboratoire à différentes températures du solvant organique (-20 °C, 0 °C, 15 °C et 29 °C). Leurs propriétés structurales (morphologie, topologie, épaisseur, rugosité, fraction de vide, densité apparente, densité de la phase dense et structure chimique) ont été analysées par différentes techniques comme la Microscopie Electronique à Balayage, la Microscopie à Force Atomique (AFM), la profilométrie, l’ellipsométrie, la sorption dynamique de vapeur, la spectrométrie photo-électronique X et la spectroscopie AFM à Infra-Rouge. Les deux familles de films sont constituées d’une base dense sur laquelle se trouve : une structure de type “crête-et-vallée” pour la CPA2 ; une structure avec des motifs “cheminées” pour les échantillons synthétisés. L’épaisseur moyenne et la taille des cheminées augmentent avec la température. A partir d’un taux de vide moyen de 35 % et d’une densité apparente de 0,81 g·cm-3 obtenus pour le PAA de la CPA2, on calcule pour sa phase dense une densité de 1,25 g·cm-3 pour le polymère sec, et de 1,48 g·cm-3 quand il est humide, ce qui représente une des très rares déterminations expérimentales pour le PAA dense d’une membrane commerciale. De nouveaux descripteurs ont été utilisés pour étudier le taux de réticulation de ce polymère. Dans le cas de la CPA2, ils permettent de déceler une hétérogénéité chimique dans l’épaisseur.Plusieurs constructions tout-atome du PAA ont été réalisées en créant des liaisons amides entre le chlorure de trimesoyle (TMC) et le m-phenylènediamine (MPD), pour des rapports initiaux en monomères (MPD : TMC) variant entre 0,25 et 5. On souhaite mimer ainsi les hétérogénéités de composition dans les membranes et comprendre l’influence des concentrations initiales en réactifs sur la structure du film. Plusieurs étapes de modélisation ont été nécessaires pour atteindre l’équilibre, en particulier une longue simulation (plusieurs microsecondes) à tenseur de pression et température constantes. La composition en monomères dans les structures construites varie entre 0,68 et 2,61, correspondant à des fractions de groupements acyl/amine ayant réagi, respectivement de 0,45/1,0 à 0,99/0,57. Ces résultats sont cohérents avec les structures de films de PAA expérimentaux. La densité moyenne des boîtes de simulation est pratiquement indépendante du détail de la structure, de l’ordre de 1,26 g·cm-3, en accord avec nos résultats sur la CPA2.Des isothermes de sorption d’eau ont ensuite été réalisés pour l’ensemble des films expérimentaux et par Monte Carlo dans l’ensemble osmotique pour plusieurs matrices polymères simulées. A faible activité en eau, les résultats simulés sont cohérents avec ceux des films expérimentaux, validant ainsi l’ensemble de la méthodologie de modélisation. A forte activité en eau, la prise en eau est inférieure à celle observée expérimentalement. Ceci pourrait être attribué à la présence de “vides” dans les matériaux réels. Enfin, on note une quasi absence de gonflement en simulation, en accord avec nos résultats expérimentaux pour la CPA2<br>Commercial reverse osmosis (RO) membranes typically consist of an active aromatic polyamide layer (APA, thickness ∼200 nm), polymerized on a porous polysulfone support, itself attached to a polyester backing fabric. RO membranes are widely used in industrial waste-water treatments and their performances are essentially dominated by the active APA layer. However, neutral organic molecules rejections and the corresponding transfer behaviors are difficult to predict. In this work, we combined experimental structural characterizations and molecular modeling investigations on APA films, in order to improve transfer understanding at molecular level.APA layer of commercial CPA2 RO membrane and a set of free-standing APA films synthesized at four organic solvent temperatures (-20°C, 0°C, 15°C and 29°C) were investigated. Their structural properties including the morphology, topology, thickness, roughness, void fraction, effective density, dense layer density and chemical structure were characterized via various techniques such as Field Emission Scanning Electron Microscopy (FE-SEM), Atomic Force Microscopy (AFM), Profilometry, Spectroscopic Ellipsometry, Dynamic water sorption (DVS), X-ray photoelectron spectra (XPS) and Atomic force microscopy-based infrared spectroscopy (AFM-IR). Both film types had a multi-level topological structure with a dense base upon which generates: a valley-ridge structure for CPA2 or a chimney-like structure for synthesized samples, for which thickness and chimneys size increased with temperature. Based on the obtained average void fraction of 35% and the apparent volumetric density of 0.81 g·cm-3, the density of the dense regions of CPA2 APA layer was calculated at 1.25 g·cm-3 when dry and 1.48 g·cm-3 when hydrated. This completes the very few experimental density values found for the dense part of commercial APA films. With the help of a new set of chemical structure descriptors, the chemical depth-heterogeneity of CPA2 APA layer was investigated. The film synthesized at -20°C performed a remarkable water uptake of 65% at 91%RH, which might be attributed to its orderly distributed and small-size chimney morphology on top-surface.All-atoms molecular models of APA polymer were constructed by forming amide bonds between trimesoyl chloride (TMC) and m-phenylenediamine (MPD) with a set of initial MPD:TMC monomers ratios, varying from 0.25 to 5. The purposes were, on one hand, to mimic APA’s possible depth-dependent heterogeneous structures with boxes of different cross-linking degrees; on the other hand, to understand the effect of different initial monomer proportions during the IP on APA film’s structure. Several steps were necessary in order to obtain equilibrated samples, including a very long (several microseconds) constant stress and temperature molecular simulation. Final MPD:TMC (connected) ratios ranging from 0.68 to 2.61 were observed, corresponding to systems with acyl/amine group connectivity degrees at 45%/100% or 99%/57%, respectively. These results were consistent with chemical structure evaluation of real APA films. A similar density around 1.26 g·cm-3 were observed for all systems, consistent with the experimental density of CPA2 APA.Water sorption isotherms were computed using Monte Carlo method in osmotic ensemble for several simulated polymer matrixes and were obtained via DVS for experimental layers. At low water activity, water sorption behaviors of simulated polymers were in agreement with experimental data, validating the overall simulation methodology. At high water activity, water absorption was underestimated by molecular simulations. This could be attributed to the existence of void space in real APA films. No significant swelling was observed in simulations, which was in agreement with our experimental results for CPA2
APA, Harvard, Vancouver, ISO, and other styles
19

Méricq, Jean-Pierre. "Approche intégrée du dessalement d’eau de mer : Distillation membranaire sous vide pour la réduction des rejets salins et possibilités de couplage avec l’énergie solaire." Toulouse, INSA, 2009. http://eprint.insa-toulouse.fr/archive/00000341/.

Full text
Abstract:
Le problème de pénurie en eau potable se pose encore de nos jours dans de nombreux pays. Du fait de l’importance de la ressource en eau présente dans les océans, la solution du dessalement de l’eau de mer est en constant progrès. Ce dessalement se fait actuellement majoritairement par osmose inverse. Cependant, ce procédé membranaire est limité en facteur de concentration en raison de la pression osmotique de l’eau de mer qui augmente avec la concentration en sels. Il en résulte des volumes importants de rejets salins dans l’eau de mer ce qui perturbe l’équilibre du milieu naturel. Une approche originale a été proposée dans le cadre du projet européen MEDINA afin de réduire ces rejets. Il s’agit de l’utilisation du procédé de distillation membranaire sous vide (DMV) au sein d’une filière intégrée d’OI. En effet, la DMV permet d’opérer à de fortes concentrations en sels et elle peut également être couplée avec l’énergie solaire dans un objectif d’économie d’énergie. La démarche adoptée dans cette étude consiste à étudier l’utilisation de la DMV pour des eaux très concentrées en sels, à la fois des eaux synthétiques mais aussi des eaux réelles (eaux de mer et rétentats d’osmose inverse). Une double approche à la fois expérimentale (à l’aide d’un pilote à échelle laboratoire) et théorique (par un outil de modélisation) a été utilisée. Les résultats ont montré l’intérêt de la DMV pour la surconcentration des rétentats d’OI. En effet, la DMV peut travailler à des fortes concentrations en sels jusqu’à 300 g. L-1 tout en maintenant des flux de perméat encore importants (7 L. H-1. M-2) et un perméat avec une très faible salinité (taux de rejet en sels de 99,96 %). Les volumes de rejets peuvent ainsi être réduits par 5 et le taux de conversion augmente jusqu’à presque 90 %. Les phénomènes de colmatage (cristallin, organique et biologique) sont également limités. Des dépôts de cristaux de sels ont pu être observés et analysés. Des mécanismes de cristallisation ont été proposés mettant en évidence le rôle majeur du calcium. Le couplage de la DMV avec des technologies solaires thermiques permet une réduction importante de la demande énergétique. Les utilisations d’étangs solaires à gradient de salinité et de collecteurs solaires thermiques ont été comparées et ont montré les potentialités intéressantes des collecteurs solaires thermiques en termes de température atteinte et donc de flux de perméat<br>The lack of potable water is still a problem in many countries. Considering the nearly endless water resource in the oceans, seawater desalination is an increasing attractive solution. Reverse Osmosis (RO) desalination is the main technology used nowadays. However, RO is limited in recovery factor due to the osmotic pressure which increases with salinity. It results high brine volume rejected directly in seawater which induces environmental perturbations. An innovative approach was proposed in the frame of the European project MEDINA in order to reduce these brines: the use of vacuum membrane distillation (VMD) in an integrated RO desalination process. Indeed, VMD allows operating at high salt concentration and can be coupled with solar thermal energy in order to reduce energy requirement. The present work consisted in studying use of VMD for highly salty concentrated waters, both for synthetic and real waters (seawater and RO retentate). An experimental approach was used with a lab-scale pilot plant completed by a theorical approach with a modelling tool. Results show the interest of VMD for the overconcentration of RO retentates. Indeed, VMD can be operated at high salt concentration up to 300 g. L-1 maintaining still high permeate fluxes (7 L. H-1. M-2) and nearly pure permeate (salt rejection of 99. 96 %). Brine volumes can so be reduced by 5 and recovery factor increased up to nearly 90 %. Fouling (organic, scaling or bio-fouling) is limited. Salt crystal deposit has been observed and analysed. Precipitation mechanisms have been proposed, mainly with the crucial part of the calcium. VMD coupling with solar thermal technologies allow an important reduction of the energy requirement. Use of salinity gradient solar ponds and solar thermal collectors have been compared and have shown the potentialities of using solar thermal collector in order to obtain high temperatures and so high permeate fluxes
APA, Harvard, Vancouver, ISO, and other styles
20

Jacob, Matthieu. "Réutilisation des eaux usées épurées par association de procédés biologiques et membranaires." Thesis, Toulouse, INSA, 2011. http://www.theses.fr/2011ISAT0040/document.

Full text
Abstract:
Les procédés de réutilisation des eaux usées doivent être robustes, fiables et rentables pour que leur utilisation se démocratise et devienne complémentaire des traitements des eaux de surface. Le couplage d’un procédé biologique et de procédés membranaires représente une solution prometteuse pour répondre à ces challenges. Cette étude se focalise sur l’impact des conditions de fonctionnement du procédé secondaire (en particulier par bioréacteur à membrane BAM) sur le colmatage du procédé tertiaire de nanofiltration (NF) ou d’osmose inverse (OI) ainsi que sur le devenir des micropolluants et microorganismes tout au long de la chaine de traitement. Dans un premier temps, des expériences à court terme de filtration avec différentes membrane NF et d’OI ont été réalisées afin de caractériser les interactions entre effluents secondaires et membranes. Il a ainsi été observé de très fortes rétentions de tous les micropolluants ciblés par la Directive Cadre Européenne. En termes de colmatage, la chute de flux de l’OI, essentiellement liée pour ces essais de courte durée à une augmentation de pression osmotique puis à un dépôt de cristaux minéraux, peut être maîtrisée en contrôlant le pH et la concentration en carbonate et phosphate de l’effluent secondaire. Par ailleurs, des chutes de flux plus importantes sont observées lors des filtrations réalisées avec les membranes de NF qui sont plus sensibles au colmatage irréversible. Dans un second temps, l’optimisation de la filière de traitement des eaux usées urbaines couplant un bioréacteur à membranes à un procédé d’OI a été réalisée à partir d’une unité pilote fonctionnant en continu. La sélection de conditions opératoires adéquates a permis de faire fonctionner le procédé d’OI pendant plus de quatre mois sans qu’aucune maintenance ne soit réalisée. Une faible chute de flux de l’OI, linéaire sur toute la période de filtration, essentiellement dû à l’adsorption de molécules organiques à la surface de la membrane, a été observée. Sur l’ensemble de la période d’essais, la filière BAM/OI permet d’obtenir un abattement optimal en micropolluants présents. Lorsque des micropolluants sont injectés à des concentrations plus élevées (simulation d’une brusque dégradation de la qualité des eaux en entrée de filière) dans le bioréacteur, une chute de l’activité de la biomasse couplée à un relargage de produits microbiens solubles peut être observée. Néanmoins, ces pics de pollution n’ont eu aucun impact sur le colmatage de la membrane du BAM ni sur celle de l’OI. La filière BAM-OI permet donc de garantir un taux de rejet élevé et une productivité d’environ 15 L.h-1.m2 quelles que soient les fluctuations de la composition de l’eau usée urbaine à traiter<br>In order to be competitive compare to surface water treatments, wastewater reuse needs robust, reliable and profitable combination of technologies. The combination of bioreactors and membrane processes seems to be a promising solution to these challenges. This study focus on the impact of the operating conditions of the secondary treatment (particularly the membrane bioreactor (MBR)) on the nanofiltration (NF) and reverse osmosis (RO) tertiary treatments as well as the fate of micropollutants and microorganisms along the treatment line. Firstly, short term filtration experiments with various NF and RO membranes were performed in order to characterize the interactions between secondary treatment effluents (STE) and membranes. High retentions of micropollutants listed by the European water framework directive were observed. During these short term experiments, RO flux decline is mainly due to an increase of osmotic pressure and then a precipitation of salts that can be solved by controlling the pH and thus the carbonate and phosphate concentration of the STE. In addition, higher flux declines are observed with NF because of a higher irreversible fouling behavior. Secondly, continuous long term tests were performed on a pilot unit combining a MBR and a RO processes. The appropriate selection of operating conditions allowed treating wastewater during more than four months without any maintenance. A linear low flux decline, mainly due to adsorption of organic molecules at the membrane surface was observed. During this filtration period, the MBR/RO process presented very high micropollutant retentions. When micropollutants are injected at higher concentration (simulation of sudden fluctuation of feed composition) into the MBR, a drop of biomass activity combined with soluble microbial products release can be observed. Nevertheless, these peaks of pollution did not cause any additional fouling of MBR as well as RO membranes. MBR/RO process is then a reliable technology that can guaranty high retention and productivity (around 15 L.h-1.m-2) whatever the fluctuations of the feed composition
APA, Harvard, Vancouver, ISO, and other styles
21

Luo, Jianquan. "Traitement d'effluents industriels par filtration membranaire dynamique à fort cisaillement." Compiègne, 2012. http://www.theses.fr/2012COMP2026.

Full text
Abstract:
La filtration membranaire est facile à combiner avec d’autres technologies pour traiter les eaux usées industrielles, en produisant de l'eau réutilisable et en récupérant des composants organiques/inorganiques. Le déclin du flux à cause de la polarisation de concentration et du colmatage de la membrane est une limitation importante dans l'application des technologies membranaires pour traiter les eaux usées. Afin de contrôler le déclin du flux, la filtration membranaire à fort cisaillement a été utilisée pour traiter les eaux usées de nettoyage et laitières dans ce travail. Les comportements du flux, les mécanismes de colmatage, le rôle des polluants et les stratégies de contrôle du colmatage dans le traitement des eaux usées par la filtration membranaire avec un cisaillement amélioré ont été étudiés pour fournir de précieuses informations pour les applications industrielles. Le déclin du flux dans le traitement des eaux usées détergentes par nanofiltration (NF) peut être restreint lorsque la couche de polarisation de concentration tensioactive est éliminée par un taux de cisaillement élevé sur la membrane. L’augmentation du pH a eu un effet positif en augmentant la répulsion électrostatique entre les molécules de surfactant et de la membrane. Le colmatage de la membrane peut être éliminé par un rinçage à l'eau, et la perméabilité membranaire récupérée complètement sans nettoyage chimique. Le colmatage des membranes dans le traitement des eaux usées laitières est plus compliqué. Avec un taux de cisaillement et une pression élevés, un léger déclin du flux dû à l'adsorption des polluants (le lactose, les ions multivalents de sel et leurs agrégats) est observé. Pendant cette phase, le colmatage par adsorption en surface, le rétrécissement et le colmatage des pores, régis par l’interaction de polluants-membrane, sont les mécanismes principaux de réduction du flux. En l'absence de nettoyage chimique, ce colmatage par adsorption peut induire la formation d’un gâteau par des agrégats de protéines et du calcium, ce qui entraîne un fort déclin du flux. Un prétraitement par ultrafiltration (UF) peut réduire le colmatage des membranes de NF à un taux de cisaillement faible à cause de l'élimination des caséines et des protéines de lactosérum, alors qu'il a un effet négatif sur la NF lorsque que le taux de cisaillement est élevé. Nous avons proposé les conditions opératoires suivantes : conditions hydrodynamiques extrêmes et celles d’un flux de seuil (threshold flux). La condition extrême signifie l’application d’un taux de cisaillement élevé et d’une pression de 40 bar, tandis que le fonctionnement au flux de seuil consiste à limiter le flux pour réduire le colmatage (le point au-dessus duquel le flux cesse d'augmenter linéairement avec la pression transmembranaire). Le premier mode donne un flux très élevé et une bonne qualité du perméat, mais le deuxième est intéressant pour des tests de longue durée grâce à un faible déclin du flux. Il peut être conclu qu’en utilisant la filtration dynamique, le déclin du flux peut être parfaitement contrôlé par l’application d’un fort taux de cisaillement sur la membrane. L’opération en conditions extrême avec un nettoyage chimique approprié et l’opération du flux de seuil avec un colmatage faible, sont deux choix possibles pour la filtration dynamique à fort cisaillement. La comparaison et l'applicabilité de ces deux opérations doivent encore être étudiées<br>Membrane filtration is easy to combine with other technologies to treat industrial wastewater, for the production of reusable water and the reutilization of organic/inorganic components. But flux decline due to concentration polarization and membrane fouling is an important limitation in applying membrane technologies to recycle wastewater. In order to reduce flux decline, shear-enhanced membrane filtration was used to treat detergent and dairy wastewaters in this work. Flux behaviors, fouling mechanisms, foulant roles and control strategies in recycling wastewater by shear-enhanced membrane filtration were investigated to provide useful information for industrial applications. The flux decline in the treatment of detergent wastewater by nanofiltration (NF) could be controlled as the surfactant concentration polarization layer was reduced by high shear rate on the membrane. Increasing feed pH had a positive effect by enhancing electrostatic repulsion between surfactant molecules and membrane. The membrane fouling layer could be broken up by water rinse, and thus membrane permeability could be fully recovered without any chemical cleaning. Membrane fouling in the treatment of dairy wastewater was more complicated. When operating at high shear rate and pressure, after a stable flux period, a slow flux decline caused by surface adsorption of foulants (lactose, multivalent salt ions and their aggregates) occurred. In this adsorption fouling stage, pore narrowing and blocking governed by foulant–membrane interaction were the main fouling mechanisms. In absence of chemical cleaning, this adsorption fouling could induce cake fouling formation by proteins-calcium aggregates, resulting in severe flux decline. Ultrafiltration (UF) pretreatment could reduce NF membrane fouling at low shear rate due to the elimination of caseins and whey proteins, while it had a negative effect on NF of UF permeate at high shear rates. Two new membrane operations, i. E. At extreme hydrodynamic conditions and threshold flux conditions, were proposed. Extreme hydrodynamic conditions consists in high shear rate and high applied pressure (up to 40 bar), while threshold flux operation implies limiting the flux to reduce fouling (the point above which flux ceases to increase linearly with transmembrane pressure). The former had high process efficiency and good permeate quality, but the latter is advantageous in long-term runs due to low flux decline. It can be concluded that, using shear-enhanced membrane filtration, flux decline can be well controlled by its high shear rate on the membrane. Extreme hydrodynamic operation with suitable chemical cleaning and threshold flux operation with low fouling rate, are two possible choices for dynamic shear-enhanced membrane process. The comparison and applicability of these two operations need to be further studied
APA, Harvard, Vancouver, ISO, and other styles
22

Lopes, Gustavo Henndel. "On the coupling of membrane transport to hydrodynamics and bulk mass transfer in reverse osmosis : numerical modeling and experimental studies." Thesis, Ecole centrale de Marseille, 2014. http://www.theses.fr/2014ECDM0013/document.

Full text
Abstract:
La prédiction des performances des séparations membranaires barométriques, fortement affectées par la polarisation de concentration, serait une avancée importante pour le dimensionnement et l’optimisation des procédés. Dans ce contexte, les équations couplées de Navier-Stokes et de conservation du soluté adimensionnées sont résolues numériquement dans le cas d’un écoulement stationnaire laminaire en filtration tangentielle. Le canal plan bidimensionnel comporte des parois perméables soumises à des conditions aux limites du type solubilisation-diffusion. Le flux de perméat, le taux de rétention et le débit, la concentration et la chute de pression du rétentat sont déterminés localement. Les simulations soulignent l’influence des perméabilités membranaires au soluté et au solvant sur la polarisation de concentration et la dépendance non-asymptotique du taux de rétention avec la pression appliquée. Le modèle est validé pour des modules plans et spiralés d’osmose inverse et de nanofiltration dense en comparant les calculs à des résultats expérimentaux tirés de la littérature et de nos propres essais pilotes de dessalement. Aussi, une méthode à l’échelle de la paillasse permettant de déterminer les perméabilités au soluté et au solvant par des expériences d’osmose et diffusion est développée et appliquée à des membranes d’osmose inverse et de nanofiltration. La divergence des mécanismes de transfert engendrés sous l’influence de la pression ou sous l’influence d’un gradient osmotique est mise en évidence. Le modèle numérique et la méthode expérimentale sont des outils prometteurs d’applicabilité immédiate dans le domaine des membranes<br>The prediction of the performance of pressure-driven membrane separations, deeply affected by concentration polarization, would be an important advance for process design and optimization. In this context, the dimensionless coupled Navier-Stokes and solute conservation equations are solved numerically for a steady laminar cross-flow filtration. The two-dimensional flat channel consists of permeable walls subject to solution-diffusion boundary conditions. The permeate flux, the rejection rate and the retentate’s flow rate, concentration and pressure drop are determined locally. The simulations highlight the influence of the membrane solute and solvent permeabilities on concentration polarization and the non-asymptotic dependence of the rejection rate on the applied pressure. The model is validated for reverse osmosis and tight-nanofiltration plate-and-frame and spiral-wound modules by comparison to experimental results from the literature and from our own pilot desalination tests. Furthermore, a bench-scale method enabling the determination of solute and solvent permeabilities from osmotic-diffusive experiments is developed and applied to reverse osmosis and nanofiltration membranes. The divergence between the transport mechanisms engendered by pressure and by an osmotic gradient is evidenced. The numerical model and the experimental method are new promising tools with immediate applicability in the membrane field
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!