To see the other types of publications on this topic, follow the link: Karman's cannula.

Journal articles on the topic 'Karman's cannula'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 27 journal articles for your research on the topic 'Karman's cannula.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse journal articles on a wide variety of disciplines and organise your bibliography correctly.

1

Tomar, Neetu Sangwan, Seerat Sandhu, Supriya Mahipal, and Abhimanyu Chaudhary. "A comparative study to evaluate endometrial aspiration using Karman’s cannula versus dilatation and curettage in cases of abnormal uterine bleeding." International Journal of Reproduction, Contraception, Obstetrics and Gynecology 9, no. 3 (2020): 1218. http://dx.doi.org/10.18203/2320-1770.ijrcog20200903.

Full text
Abstract:
Background: Abnormal uterine bleeding (AUB) is defined as any variation from the normal menstrual cycle such as changes in regularity, frequency, duration of flow or amount of flow. Objective of this study was to compare the adequacy and diagnostic accuracy of endometrial aspiration using Karman’s cannula versus dilatation and curettage in women with abnormal uterine bleeding.Methods: This prospective study was conducted on 250 women with AUB in age group of more than 40 years. In all patients, endometrial aspiration was done with manual vacuum aspiration (MVA) syringe attached to 4 mm Karman'
APA, Harvard, Vancouver, ISO, and other styles
2

International, Journal of Medical Science and Innovative Research (IJMSIR). "Diagnostic Efficacy of Endometrial Aspiration Cytology with Histopathological Correlation." International Journal of Medical Science and Innovative Research (IJMSIR) 9, no. 6 (2024): 08–14. https://doi.org/10.5281/zenodo.15449508.

Full text
Abstract:
<strong>Abstract</strong> <strong>Introduction</strong>: Endometrial cytopathology is a powerful tool for the detection of a wide variety of benign atypias, inflammatory changes, and infectious organisms. It is also helpful for the cyto-hormonal evaluation of patients and the detection of endometrial malignancies. <strong>Aims</strong>: To assess the diagnostic accuracy of endometrial aspiration technique and to compare the cyto-morphology of aspirated smears with histopathology<sup> </sup> Materials and Methods:<em> </em>Endometrial aspiration was performed using Karman&rsquo;s cannula in 100
APA, Harvard, Vancouver, ISO, and other styles
3

Gupta, Meeta, Puneeta Gupta, and Poonam Yadav. "A randomized comparative study to compare Karman's cannula and pipelle biopsy for evaluation of abnormal uterine bleeding." Journal of Mid-life Health 13, no. 1 (2022): 67. http://dx.doi.org/10.4103/jmh.jmh_292_20.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Zutshi, Vijay, Monika Gupta, Panchampreet Kaur, Aarzoo Malik, Sufian Zaheer, and Puneet Gambhir. "Office endometrial sampling: a comparison between Endosampler and Karman cannula number 4." International Journal of Reproduction, Contraception, Obstetrics and Gynecology 7, no. 10 (2018): 3965. http://dx.doi.org/10.18203/2320-1770.ijrcog20183874.

Full text
Abstract:
Background: Endometrial aspiration biopsy is one of the primary steps in diagnostic evaluation of a women presenting with suspected endometrial pathology. The aim of present study was to compare specimen adequacy, ease of doing the procedure, patient comfort and cost effectiveness in office endometrial sampling by endosampler vs Karman cannula number 4.Methods: This was a prospective comparative study where 102 patients were included. In 50% of patients, endosampler was used and Karman cannula was used in the rest. All procedures were noted, analysed and done in outpatient department and vario
APA, Harvard, Vancouver, ISO, and other styles
5

Cho, J. Y., S. H. Cha, and S. Y. Kim. "Curved Karman cannula for suction curettage." International Journal of Gynecology & Obstetrics 42, no. 3 (1993): 273–74. http://dx.doi.org/10.1016/0020-7292(93)90225-l.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Kumar, Atul, and Alka Kumar. "Broken Tip of Karman Cannula Removed at Hysteroscopy." Journal of Minimally Invasive Gynecology 21, no. 4 (2014): 537–38. http://dx.doi.org/10.1016/j.jmig.2013.12.093.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Kumar, Atul, and Alka Kumar. "Broken Tip of Karman Cannula Removed at Hysteroscopy." Journal of Minimally Invasive Gynecology 22, no. 4 (2015): 700–701. http://dx.doi.org/10.1016/j.jmig.2015.02.004.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Karasahin, Kazim Emre, and Ibrahim Alanbay. "Comment on “Broken Tip of Karman Cannula Removed at Hysteroscopy”." Journal of Minimally Invasive Gynecology 22, no. 4 (2015): 699–700. http://dx.doi.org/10.1016/j.jmig.2015.01.033.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Anant, Monika. "Novel use of Karman Cannula: Repositioning of malpositioned intrauterine contraceptive device." Eastern Journal of Medical Sciences 2, no. 4 (2017): 52–53. http://dx.doi.org/10.32677/ejms.2017.v02.i04.001.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

C Ngene, Nnabuike. "Multiple uterine perforations during manual vacuum aspiration: the need to increase the clinical awareness of attending healthcare professionals." African Health Sciences 22, no. 1 (2022): 180–2. http://dx.doi.org/10.4314/ahs.v22i1.23.

Full text
Abstract:
Background: The risk of uterine perforation during manual vacuum aspiration (MVA) is reduced by using Karman cannula (which has a rounded tip) during the procedure.&#x0D; Methods: A 35-year-old multigravida at 13 gestational weeks presented with vaginal bleeding of a day duration and ultrasound evidence of retained products of conception suggestive of incomplete miscarriage. The patient was rhesus D positive and stable. She had MVA which was performed using Karman cannula, and developed severe vaginal bleeding. The differential diagnoses were incomplete uterine evacuation and uterine perforati
APA, Harvard, Vancouver, ISO, and other styles
11

Insogna, I., S. A. Missmer, L. V. Farland, E. S. Ginsburg, and P. Brady. "Karman cannula aspiration: an alternative to presumptive methotrexate for pregnancy of unknown location after IVF." Fertility and Sterility 106, no. 3 (2016): e343. http://dx.doi.org/10.1016/j.fertnstert.2016.07.971.

Full text
APA, Harvard, Vancouver, ISO, and other styles
12

Brady, Paula, Anthony N. Imudia, Awoniyi O. Awonuga, Diane L. Wright, Aaron K. Styer, and Thomas L. Toth. "Pregnancies of unknown location after in vitro fertilization: minimally invasive management with Karman cannula aspiration." Fertility and Sterility 101, no. 2 (2014): 420–26. http://dx.doi.org/10.1016/j.fertnstert.2013.10.056.

Full text
APA, Harvard, Vancouver, ISO, and other styles
13

Huy, H. Pham. "O749 Evaluation of the evacuation of molar pregnancy by using Karman plastic cannula with manual vacuum aspiration (MVA) and electric aspiration." International Journal of Gynecology & Obstetrics 107 (October 2009): S307. http://dx.doi.org/10.1016/s0020-7292(09)61122-x.

Full text
APA, Harvard, Vancouver, ISO, and other styles
14

Kilicci, Cetin, Ebru Çogendez, Pınar Kumru, Evrim Bostanci Ergen, Nermin Koc, and Cigdem Abide Yayla. "Cytological assessment of endometrial washings obtained with Karman cannula using a liquid-based preparation method for the detection of endometrial pathologies." Archives of Gynecology and Obstetrics 298, no. 1 (2018): 171–77. http://dx.doi.org/10.1007/s00404-018-4788-3.

Full text
APA, Harvard, Vancouver, ISO, and other styles
15

Giampaolino, P., N. De Rosa, I. Morra, et al. "Management of Cesarean Scar Pregnancy: A Single-Institution Retrospective Review." BioMed Research International 2018 (March 5, 2018): 1–9. http://dx.doi.org/10.1155/2018/6486407.

Full text
Abstract:
Objective. Cesarean scar pregnancy (CSP) is a rare condition that occurs when the pregnancy implants in a cesarean scar. An early diagnosis and a proper management are fundamental to prevent maternal complications. We review and discuss the different treatment employed in our unit to reduce morbidity, preserve fertility, and predict possible complications. Methods. The reported treatment has been expectant management, operative hysteroscopy approach, and intramuscular injection of 50 mg methotrexate (MTX), followed by cervical dilation and manual vacuum aspiration (D&amp;S) with a Karman cannu
APA, Harvard, Vancouver, ISO, and other styles
16

S Saleh, Hend, Hala E Sherif, and Eman M Mahfouz. "Single Dose of Methotrexate Therapy Followed By Suction Curettage for Management of Cesarean Scar Pregnancy." Obstetrics Gynecology and Reproductive Sciences 3, no. 1 (2019): 01–04. http://dx.doi.org/10.31579/2578-8965/028.

Full text
Abstract:
Objective Implantation of the pregnancy in a cesarean scar is a rare condition named ; Cesarean scar pregnancy (CSP). Maternal complications can be prevented with the early diagnosis and an appropriate management .It is a Prospective clinical study to evaluate the efficacy and success rate of single dose use of methotrexate (MTX) followed by dilation and suction (D&amp;S) regimen in management of women with cesarean scar pregnancy (CSP) . Methods 50mg of MTX in the form of a single dose Intramuscular injection then cervical dilatation and suction aspiration with a Karman cannula(D&amp;S) under
APA, Harvard, Vancouver, ISO, and other styles
17

Saleh, Hend. "Single Dose of Methotrexate Therapy Followed By Suction Curettage for Management of Cesarean Scar Pregnancy." Obstetrics Gynecology and Reproductive Sciences 3, no. 3 (2019): 01–05. http://dx.doi.org/10.31579/2578-8965/028.

Full text
Abstract:
Objective Implantation of the pregnancy in a cesarean scar is a rare condition named ; Cesarean scar pregnancy (CSP). Maternal complications can be prevented with the early diagnosis and an appropriate management .It is a Prospective clinical study to evaluate the efficacy and success rate of single dose use of methotrexate (MTX) followed by dilation and suction (D&amp;S) regimen in management of women with cesarean scar pregnancy (CSP) . Methods 50mg of MTX in the form of a single dose Intramuscular injection then cervical dilatation and suction aspiration with a Karman cannula(D&amp;S) under
APA, Harvard, Vancouver, ISO, and other styles
18

Kochar, Swati, Kirti Solanki, Laxmi Poonia, Priyanka Gaur, Krishna Poonia, and Shweta Choudhary. "A comparison of endometrial sampling histopathology by Pipelle curette versus Karman cannula in patients with abnormal uterine bleeding at a tertiary care hospital in Northwest Rajasthan." Journal of Current Research in Scientific Medicine 7, no. 2 (2021): 87. http://dx.doi.org/10.4103/jcrsm.jcrsm_23_21.

Full text
APA, Harvard, Vancouver, ISO, and other styles
19

S Saleh, Hend, Hala E Sherif, and Eman M Mahfouz. "Single dose of Methotrexate therapy followed by suction curettage for management of Cesarean Scar Pregnancy." MOJ Women's Health 9, no. 2 (2020): 45–48. http://dx.doi.org/10.15406/mojwh.2020.09.00268.

Full text
Abstract:
Aim: To evaluate the efficacy and safety of single dose of of Systemic MTX 50 mg/m2 followed by D&amp;S in cases of Cesarean scar pregnancy (CSP). Objective: Implantation of the pregnancy in a cesarean scar is a rare condition named; Cesarean scar pregnancy (CSP). Maternal complications can be prevented with the early diagnosis and an appropriate management. It is a prospective clinical study to evaluate the efficacy and success rate of single dose use of methotrexate (MTX) followed by dilation and suction (D&amp;S) regimen in the management of women with cesarean scar pregnancy (CSP). Methods
APA, Harvard, Vancouver, ISO, and other styles
20

Rajlaxmi Mundhra, Prerna Kumari, Anupama Bahadur, et al. "Correlation of endometrial thickness using transvaginal sonography with histopathology in women with abnormal uterine bleeding: A cross-sectional study." Asian Journal of Medical Sciences 14, no. 7 (2023): 122–26. http://dx.doi.org/10.3126/ajms.v14i7.50450.

Full text
Abstract:
Background: Abnormal uterine bleeding (AUB) is one of the most common complaints seen in gynecological practice, and transvaginal sonography (TVS) remains the first-line, non-invasive diagnostic tool in these women. Aims and Objectives: The aim was to study the endometrial thickness (ET) using TVS and correlate it with histopathological findings obtained through endometrial biopsy in patients with AUB. Materials and Methods: This was a prospective observational study conducted in a tertiary care center in Northern India, from January 2018 to June 2019. One hundred and sixty women in the reprod
APA, Harvard, Vancouver, ISO, and other styles
21

"Endometrial Aspiration Cytology by Karman's Cannula with Histopathological Correlation." International Journal of Science and Research (IJSR) 6, no. 12 (2017): 1679–83. http://dx.doi.org/10.21275/art20179120.

Full text
APA, Harvard, Vancouver, ISO, and other styles
22

Bulutlar, Eralp, and Gizem Berfin Uluutku Bulutlar. "Efficacy of Cold Karman Cannulae in Reducing Pain During Office-Based Endometrial Biopsy: A Prospective Randomized Controlled Trial." Gynecology Obstetrics & Reproductive Medicine, February 21, 2025, 1–6. https://doi.org/10.21613/gorm.2025.1537.

Full text
Abstract:
Objective: The study aimed to evaluate the efficacy of cold Karman cannulae, stored at -17°C, in reducing pain levels during office-based endometrial biopsy procedures. Study Design: This prospective, randomized controlled trial was conducted between 2021 and 2022, involving 300 female patients aged 30-60, with abnormal uterine bleeding or increased endometrial thickness. Participants were randomly assigned to two groups: the experimental group, which used cold Karman cannulae (n=150), and the control group, which used room temperature cannulae (n=150). Pain levels were assessed using the Nume
APA, Harvard, Vancouver, ISO, and other styles
23

Ajmera, Swarnlata, Seema Gupta, and Rohit Ajmera. "DIAGNOSTIC EFFICACY OF ENDOMETRIAL ASPIRATION CYTOLOGY WITH HISTOPATHOLOGICAL CORRELATION." International Journal of Medical and Biomedical Studies 5, no. 7 (2021). http://dx.doi.org/10.32553/ijmbs.v5i7.1997.

Full text
Abstract:
Background: To assess the diagnostic accuracy of endometrial aspiration technique and to compare the cyto-morphology of aspirated smears with histopathology&#x0D; Methods: Endometrial aspiration was performed using Karman’s cannula in 100 cases who presented with abnormal uterine bleed, infertility and postmenopausal bleed. The endometrial specimens obtained by D&amp;C were processed and evaluated histologically. The endometrial aspirated smears were reviewed for cytomorphological findings and were correlated with histopathological findings for diagnostic accuracy.&#x0D; Results: Aspiration cy
APA, Harvard, Vancouver, ISO, and other styles
24

Jain, Namita, Seema Sharma, Isha Kriplani, and Alka Kriplani. "A Foreign Body (Broken Karman’s Cannula Tip No. 8) in Uterus: Nightmare for an Obstetrician." Journal of Obstetrics and Gynecology of India, December 8, 2023. http://dx.doi.org/10.1007/s13224-023-01908-y.

Full text
APA, Harvard, Vancouver, ISO, and other styles
25

"Effect of Tissue Fragments Remain in the Karman Cannula on the Histopathological Diagnosis of Abnormal Uterine Bleeding." Journal of the College of Physicians and Surgeons Pakistan 34, no. 11 (2024): 1390–92. http://dx.doi.org/10.29271/jcpsp.2024.11.1390.

Full text
APA, Harvard, Vancouver, ISO, and other styles
26

"Effect of Tissue Fragments Remain in the Karman Cannula on the Histopathological Diagnosis of Abnormal Uterine Bleeding." Journal of the College of Physicians and Surgeons Pakistan 34, no. 11 (2024): 1648–50. http://dx.doi.org/10.29271/jcpsp.2024.11.1648.

Full text
APA, Harvard, Vancouver, ISO, and other styles
27

N Desai, Killol, Vidya K Satapara, Gunvanti Rathod, and Alpeshkumar M Maru. "Evaluation and Diagnostic Utility of Endometrial Aspiration Cytology In Abnormal Uterine Bleeding In Compare With Histopathology." International Journal of pharma and Bio Sciences 13, no. 2 (2022). http://dx.doi.org/10.22376/ijpbs.2022.13.2.b30-37.

Full text
Abstract:
Abnormal uterine bleeding (AUB) is a frequently encountered problem for which women used to have gynecological consultation. Endometrial aspiration cytology (EAC) is an acceptable and valuable diagnostic procedure for screening the endometrial status. The study was conducted to evaluate the utility of EAC in women with AUB, and to compare cytological findings were compared with the histopathological findings. Cross-sectional cohort study done at different districts of Gujarat from October 2011 to June 2021. A total of 1405 patients presenting with AUB were subjected to EAC using a 4?mm Karman’
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!