Academic literature on the topic 'Keratograph'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Keratograph.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Keratograph"

1

Chen, Minjie, Anji Wei, Jianjiang Xu, Xingtao Zhou, and Jiaxu Hong. "Application of Keratograph and Fourier-Domain Optical Coherence Tomography in Measurements of Tear Meniscus Height." Journal of Clinical Medicine 11, no. 5 (2022): 1343. http://dx.doi.org/10.3390/jcm11051343.

Full text
Abstract:
To compare the interoperator repeatability of tear meniscus height (TMH) measurements obtained with a keratograph and Fourier-domain optical coherence tomography (FD-OCT) and to assess the agreement between the methods.Forty-seven eyes with DED and 41 healthy eyes were analyzed using the Schirmer test I and tear breakup time test (TBUT). The TMH was measured three times with each device. The repeatability of measurements was assessed by within-subject standard deviation (Sw), repeatability (2.77 Sw), coefficient of variation (CoV) and intraclass correlation coefficient (ICC). Efficacy in detec
APA, Harvard, Vancouver, ISO, and other styles
2

Park, Seo Woo, Ha-Rim So, Ji Won Baek, et al. "A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients." Journal of the Korean Ophthalmological Society 66, no. 4 (2025): 175–80. https://doi.org/10.3341/jkos.2025.66.4.175.

Full text
Abstract:
Purpose: To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.Methods: From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a sca
APA, Harvard, Vancouver, ISO, and other styles
3

García-Marqués, José Vicente, Noelia Martínez-Albert, Cristian Talens-Estarelles, Santiago García-Lázaro, and Alejandro Cerviño. "Repeatability of Non-invasive Keratograph Break-Up Time measurements obtained using Oculus Keratograph 5M." International Ophthalmology 41, no. 7 (2021): 2473–83. http://dx.doi.org/10.1007/s10792-021-01802-4.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Shin, Haeeun, Soyeon Jung, and Ji Won Jung. "Comparison of Each Eye According to the Order of Noninvasive Keratographic Tear Film Evaluation." Korean Journal of Ophthalmology 37, no. 3 (2023): 230–35. http://dx.doi.org/10.3341/kjo.2022.0135.

Full text
Abstract:
Purpose: To investigate the effect of order of examination on the results of noninvasive keratograph tear film evaluation using Keratograph5M in dry eye patients.Methods: One hundred and four patients with dry eye symptoms were analyzed retrospectively. All patients underwent bilateral noninvasive tear film evaluation using measurements of tear meniscus height (TMH) and noninvasive keratograph break-up time (NIKBUT) obtained using Keratograph5M. Measurements were performed sequentially in the order of right TMH, left TMH, right NIKBUT, and left NIKBUT.Results: There was no statistically signif
APA, Harvard, Vancouver, ISO, and other styles
5

Best, N., L. Drury, and J. S. Wolffsohn. "Clinical evaluation of the Oculus Keratograph." Contact Lens and Anterior Eye 35, no. 4 (2012): 171–74. http://dx.doi.org/10.1016/j.clae.2012.04.002.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Arriola, Villalobos P., Vigo JI Fernández, Valle D. Diaz, nieves JE Peraza, Pérez C. Fernández, and del Castillo JM Benítez. "Assessment of lower tear meniscus measurements obtained with Keratograph and agreement with Fourier-domain optical-coherence tomography." Br J Ophthalmol 99, no. 8 (2015): 1120–5. https://doi.org/10.1136/bjophthalmol-2014-306453.

Full text
Abstract:
<strong>Aims:&nbsp;</strong>To compare intraobserver repeatability and interobserver and intersession reproducibility of lower tear meniscus height measurements (LTMH) obtained with the new Keratograph 5M and a Fourier-domain optical-coherence tomography (OCT; Spectralis OCT) and to assess the agreement between the two devices. <strong>Methods:&nbsp;</strong>This is a observational cross-sectional study. Thirty eyes of 30 normal subjects were randomly imaged twice with both devices in our setting. Two examiners randomly made LTMH measurements using the devices. To assess intraobserver repeatab
APA, Harvard, Vancouver, ISO, and other styles
7

Shin, Haeeun, Soyeon Jung, and Ji Won Jung. "Effects of Non-invasive Keratograph Break-Up Time on the Repeatability of Keratometry Measurements." Journal of the Korean Ophthalmological Society 64, no. 2 (2023): 99–107. http://dx.doi.org/10.3341/jkos.2023.64.2.99.

Full text
Abstract:
Purpose: To evaluate the effects of the non-invasive keratograph break-up time on the repeatability of keratometric measurements derived using the Keratograph 5M in patients with dry eye syndrome.Methods: Thirty-six patients with dry eye and 30 controls were enrolled. We measured keratometric values twice in all subjects and explored whether the two measurements differed by more than 0.5 diopter (D) (the absolute value). We also evaluated the relationship between the absolute difference and the non-invasive keratograph break-up time (NIKBUT).Results: The intraclass correlation coefficients for
APA, Harvard, Vancouver, ISO, and other styles
8

Srinivasan, Sruthi, Kara Menzies, Luigina Sorbara, and Lyndon Jones. "Non-contact meibography using a novel keratograph." Contact Lens and Anterior Eye 35 (December 2012): e31-e32. http://dx.doi.org/10.1016/j.clae.2012.08.099.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Inferrera, Leandro, Emanuela Aragona, Adam Wylęgała, et al. "The Role of Hi-Tech Devices in Assessment of Corneal Healing in Patients with Neurotrophic Keratopathy." Journal of Clinical Medicine 11, no. 6 (2022): 1602. http://dx.doi.org/10.3390/jcm11061602.

Full text
Abstract:
To prove the role of high-tech investigation in monitoring corneal morphological changes in patients with neurotrophic keratopathy (NK) using Keratograph 5M (K5M) and anterior segment OCT (AS-OCT), corneal healing was monitored with Keratograph 5M (Oculus, Wetzlar, Germany) and AS-OCT (DRI, Triton, Topcon, Tokyo, Japan) in 13 patients (8F and 5M), aged from 24 to 93 years (67.8 ± 19) with severe NK, who were treated with Cenegermin 0.002% (20 μg/mL) (Oxervate®, Dompè, Farmaceutici Spa, Milan, Italy). The surface defects were evaluated on Keratograph 5M with ImageJ software and the corneal thic
APA, Harvard, Vancouver, ISO, and other styles
10

Mencucci, Rita, Alberto Morelli, Eleonora Favuzza, Angelo Galano, Anna Maria Roszkowska, and Michela Cennamo. "Hypochlorous acid hygiene solution in patients affected by blepharitis: a prospective randomised study." BMJ Open Ophthalmology 8, no. 1 (2023): e001209. http://dx.doi.org/10.1136/bmjophth-2022-001209.

Full text
Abstract:
Background/aimsTo investigate the clinical outcomes and antimicrobial activity of an hypochlorous acid hygiene solution compared with hyaluronic acid wipes for blepharitis treatment in patients with dry eye disease (DED).MethodsThis study involved 48 eyes of 48 patients affected by blepharitis with mild to moderate DED. 24 patients were treated with a hypochlorous acid hygiene solution (HOCL group) and 24 patients were treated with hyaluronic acid wipes (HYAL group) for a period of 4 weeks. The following clinical outcomes were assessed before (V0) and after the treatment period (V1): non-invas
APA, Harvard, Vancouver, ISO, and other styles
More sources

Dissertations / Theses on the topic "Keratograph"

1

Norris, Taylor N. "Evaluation of Oculus Keratograph 5M Tear Film Scans on Eyes Wearing Contact Lenses." The Ohio State University, 2021. http://rave.ohiolink.edu/etdc/view?acc_num=osu1616608423052127.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Hartmann, Laura Katharina. "Stellenwert des Scheimpflug-Imaging in der refraktiven Hornhautchirurgie : Keratograph versus Pentacam bei myoper Laser in situ Keratomileusis." Diss., lmu, 2011. http://nbn-resolving.de/urn:nbn:de:bvb:19-126619.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Yang, Chih Huang. "Vitamin D in dry eye and myopia." Thesis, Queensland University of Technology, 2017. https://eprints.qut.edu.au/113952/1/Chih%20Huang_Yang_Thesis.pdf.

Full text
Abstract:
Vitamin D is important to human health with a variety of systemic diseases linked to vitamin D deficiency. The effect of a two month treatment of a vitamin D oral supplement on the ocular surface in older people with dry eye and on binocular vision in younger adults with short-sightedness was assessed. Vitamin D had a beneficial effect on symptoms of dry eye in older people and improved the accommodation function in younger adults. This work suggests that the development of vitamin D eye drops might be useful for these conditions.
APA, Harvard, Vancouver, ISO, and other styles
4

Carvalho, Luis Alberto Vieira de. "Desenvolvimento de um instrumento computadorizado para medida da curvatura da cornea durante o ato cirúrgico." Universidade de São Paulo, 1996. http://www.teses.usp.br/teses/disponiveis/76/76132/tde-03092010-155309/.

Full text
Abstract:
Neste trabalho foi desenvolvido um novo instrumento para monitoramento computadorizado da curvatura da região central anterior da córnea humana durante cirurgias refrativas. Através da projeção de um anel iluminado na córnea, imagens dos reflexos são digitalizadas e processadas. Algoritmos baseados em técnicas de visão computacional e geometria óptica determinam a curvatura da região central (4mm), com alta precisão e desempenho. Mapas coloridos com códigos de cor em dioptrias (proporcionais ao inverso do raio da curvatura) são gerados para auxiliar o oftalmologista cirurgião no diagnóstico.<b
APA, Harvard, Vancouver, ISO, and other styles
5

Hartmann, Laura Katharina [Verfasser]. "Stellenwert des Scheimpflug-Imaging in der refraktiven Hornhautchirurgie : Keratograph versus Pentacam bei myoper Laser in situ Keratomileusis / vorgelegt von Laura Katharina Hartmann." 2011. http://d-nb.info/1010510193/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Book chapters on the topic "Keratograph"

1

del Rosario Sánchez Valerio, María. "Current Diagnostic Tests for Dry Eye Disease in Sjögren’s Syndrome." In Eye Diseases - Recent Advances, New Perspectives and Therapeutic Options [Working Title]. IntechOpen, 2022. http://dx.doi.org/10.5772/intechopen.103671.

Full text
Abstract:
Sjogren’s syndrome (Sicca Syndrome) is mainly characterized by the presence of dry eye disease (DED). The diagnosis of DED in patients with Sjogren’s syndrome has been limited to tests such as the Schirmer test, tear breakup time (TBUT), and corneal stains; however, currently we can evaluate the functional unit in detail lacrimal, which is affected in patients with dry eye and Sjögren’s syndrome; thanks to technology that provides objective details for this difficult diagnostic. The newer evaluations that provide the greatest diagnostic value for Sjogren’s syndrome are: noninvasive keratograph
APA, Harvard, Vancouver, ISO, and other styles

Conference papers on the topic "Keratograph"

1

Klein, Stanley A. "Improvements for Video-Keratography." In Ophthalmic and Visual Optics. Optica Publishing Group, 1993. http://dx.doi.org/10.1364/ovo.1993.ofd.3.

Full text
Abstract:
Last year's meeting on Ophthalmic Optics featured two sessions on corneal topography with an excellent overview by Applegate (1992). This large interest in the field made me think that a technological breakthrough must recently have occurred in the algorithm for quantifying corneal curvature.
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!