Dissertations / Theses on the topic 'Lajas'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the top 50 dissertations / theses for your research on the topic 'Lajas.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.
Stukins, Stephen. "Spatial and temporal palynological trends in marginal marine depositional system : Lajas Formation, Neuquén Basin, Argentina." Thesis, University of Aberdeen, 2011. http://digitool.abdn.ac.uk:80/webclient/DeliveryManager?pid=167073.
Full textLatorre, Diaz Denis Fernando. "Propuesta de mejora del proceso de atención de pedidos del área de almacén para disminuir la cantidad de pedidos no atendidos en la municipalidad distrital de Lajas - Chota." Bachelor's thesis, Universidad Católica Santo Toribio de Mogrovejo, 2021. http://hdl.handle.net/20.500.12423/3442.
Full textIdrogo, Cotrina Marleni, and Delgado Olga Mercedes Carranza. "Estrategia tarea de movimiento para mejorar el aprendizaje del esquema corporal en niños de 4 años de una institución educativa de Lajas." Bachelor's thesis, Universidad Católica Santo Toribio de Mogrovejo, 2018. http://hdl.handle.net/20.500.12423/3349.
Full textChamba, Anguizaca Doménica del Rocio, and Anguizaca Doménica del Rocio Chamba. "Gestión pedagógica y calidad del servicio educativo de la I.E. “Juan León Mera” del cantón las Lajas en el periodo lectivo 2014-2015." Master's thesis, Universidad Nacional Mayor de San Marcos, 2016. http://cybertesis.unmsm.edu.pe/handle/cybertesis/5085.
Full textDetermina la relación entre la gestión pedagógica y la calidad educativa en la Institución Educativa “Juan León Mera”. Es un estudio de tipo correlacional descriptivo y de diseño no experimental de tipo transversal. La población está constituida por 390 alumnos de 5° y 6° de primaria y 4° y 5° de secundaria. La muestra es de 194 alumnos, igual número de padres de familia, 47 docentes y 3 directivos. Utiliza un instrumento validado por El Instituto Peruano de Evaluación, Acreditación y Certificación de la Calidad de la Educación Básica (IPEBA) según Resolución N° 003-2011-SINEACE/P y una encuesta elaborada por Elera (2010). Los resultados obtenidos en la investigación mediante la correlación de Rho de Spearman permiten afirmar que existe relación negativa débil según la percepción de docentes, estudiantes y padres de familia entre la gestión pedagógica y calidad del servicio educativo.
Tesis
Chamba, Anguizaca Doménica del Rocio. "Gestión pedagógica y calidad del servicio educativo de la I.E. “Juan León Mera” del cantón las Lajas en el periodo lectivo 2014-2015." Master's thesis, Universidad Nacional Mayor de San Marcos, 2016. https://hdl.handle.net/20.500.12672/5085.
Full textDetermina la relación entre la gestión pedagógica y la calidad educativa en la Institución Educativa “Juan León Mera”. Es un estudio de tipo correlacional descriptivo y de diseño no experimental de tipo transversal. La población está constituida por 390 alumnos de 5° y 6° de primaria y 4° y 5° de secundaria. La muestra es de 194 alumnos, igual número de padres de familia, 47 docentes y 3 directivos. Utiliza un instrumento validado por El Instituto Peruano de Evaluación, Acreditación y Certificación de la Calidad de la Educación Básica (IPEBA) según Resolución N° 003-2011-SINEACE/P y una encuesta elaborada por Elera (2010). Los resultados obtenidos en la investigación mediante la correlación de Rho de Spearman permiten afirmar que existe relación negativa débil según la percepción de docentes, estudiantes y padres de familia entre la gestión pedagógica y calidad del servicio educativo.
Tesis
Faron-Bartels, Renata [Verfasser]. "Piedras votivas de Pampacolca : nuevos datos sobre lajas pintadas del sur del Perú = Votivsteine aus Pampacolca : neue Daten über Steinplatten aus Südperu / Renata Faron-Bartels." Berlin : Freie Universität Berlin, 2011. http://d-nb.info/1025939530/34.
Full textPerdomo, Madelen Herrera. "Ecologia de Atta insularis Guérin (Insecta: formicidade) em uma pastagem de Leucaena leucocephala (Fabacea) e Panicum maximum (Poaceae) em San José de Las lajas, Cuba." Florianópolis, SC, 2008. http://repositorio.ufsc.br/xmlui/handle/123456789/90871.
Full textMade available in DSpace on 2012-10-23T16:15:26Z (GMT). No. of bitstreams: 1 248582.pdf: 3157063 bytes, checksum: 356bb750544cc99902e2bc4ddbd9ed51 (MD5)
Este trabalho teve como objetivo aprofundar no estúdio da ecologia da formiga cortadeira Atta insularis em uma pastagem de Leucaena leucocephala e Panicum maximum. Para isto, foi verificada a densidade, distribuição espacial e morfologia externa dos ninhos, as plantas hospedeiras, as estratégias de limpeza e forrageio e o efeito dos fatores climáticos e a sazonalidade nestas atividades. O estudo foi desenvolvido em um sistema silvipastoril de uma unidade de produção leiteira do Instituto de Ciência Animal no município San José de las Lajas, La Habana, Cuba. Na área de estudo havia dois tipos de solo: o Latossolo Vermelho Eutroférrico e o Nitossolo Vermelho Eutroférrico. As amostragens foram feitas semanalmente entre os meses de janeiro a novembro de 2007. Para conhecer a distribuição dos ninhos foram utilizados os índices de dispersão variância/média e a lei da potência de Taylor. Os testes não paramétricos de Mann-Whitney e Friedman foram empregados para verificar a influência do solo e das plantas na distribuição dos ninhos. Também foi utilizada a correlação de Spearman e as análises multivariadas de correspondência múltipla, de conglomerados e de discriminante para avaliar o efeito dos fatores climáticos e das variáveis qualitativas nas atividades de Atta insularis. A distribuição espacial dos ninhos foi de tipo agregada com 99 ninhos.ha-1. A maior ocorrência de ninhos (125 ninhos/ha), de plantas de Leucaena leucocephala (679 plantas.ha-1) e de outras plantas lenhosas (22 plantas.ha-1) foi observada no solo Nitossolo Vermelho Eutroférrico. A altura, os diâmetros, o número de olheiros e de trilhas dos montículos, apresentaram, na maioria dos casos, correlações significativas (p<0,01 e p<0,05) positivas, entre si e, negativas, com as variáveis climáticas, sendo a umidade relativa e as precipitações acontecidas antes das amostragens os fatores que mais influenciaram nestas medidas. Assim, o período pouco chuvoso e a realização da atividade de forrageio favoreceram o incremento das dimensões dos montículos. As cortadeiras coletaram 7 espécies de plantas e utilizaram mais (p<0,001) os folíolos de Leucaena leucocephala e os materiais secos de diferentes plantas, em especial de Panicum maximum. A limpeza total não teve diferenças entre os períodos do ano, no entanto, a realocação de solo foi maior (p<0,01) no período chuvoso. A atividade de forrageio teve correlações significativas (p<0,01 e p<0,05) positivas entre quase todas as medidas e negativas com os fatores climáticos. A intensidade de forrageio de Leucaena leucocephala, de seus folíolos e o forrageio total foi mais intenso nos período pouco chuvoso, as variáveis climáticas que mais influenciaram nesta atividade foram a umidade relativa e a temperatura. Conclui-se que os ninhos de Atta insularis tiveram uma distribuição espacial de tipo agregada. O solo Nitossolo Vermelho Eutroférrico teve o maior número de ninhos. A umidade relativa foi o fator climático que mais influiu na morfologia externa e nas atividades de limpeza e forrageio. No período pouco chuvoso, os montículos foram maiores e o forrageio mais intenso no sistema silvipastoril estudado.
Cevallos, Torres Rosario del Carmen. "Evaluación del desempeño docente y su relación con la enseñanza-aprendizaje del área de Estudios Sociales en los estudiantes de Educación General Básica de la Escuela “Ciudad de Loja” del cantón Las Lajas, Ecuador, periodo 2014-2015." Master's thesis, Universidad Nacional Mayor de San Marcos, 2016. https://hdl.handle.net/20.500.12672/5315.
Full textDetermina la relación que existe entre la evaluación del desempeño docente con la enseñanza-aprendizaje del área de estudios sociales en los estudiantes de Educación General Básica de la Escuela “Ciudad de Loja” del Cantón Las Lajas, Ecuador, Periodo 2014-2015. Desde la perspectiva de una investigación de tipo descriptivo utilizando el diseño correlacional; se llevó a cabo un conjunto de actividades utilizando los conceptos teóricos básicos de la evaluación del desempeño docente y la enseñanza aprendizaje del área de estudios sociales, a través del muestreo no probabilístico se eligió una muestra de 94 estudiantes del 5to año 34, del 6to año 38 y 7mo año 22 estudiantes de Educación General Básica, 02 directivos, 03 docentes del área de ciencias sociales, a quienes se les aplico mediante la técnica de la encuesta a través de un cuestionario y lista de cotejo, para la Variable Dependiente revisión de actas finales. De acuerdo a los resultados, afirma con un 95% de probabilidad que existe relación significativa entre la evaluación del desempeño docente con la enseñanza aprendizaje del área de estudios sociales en los estudiantes de Educación Básica, los datos fueron procesados estadísticamente a través de las medidas de tendencia central y están presentados en gráficos también procesados con el software estadístico SPSS 22. Finalmente, logró determinar cómo el desarrollo curricular, la gestión del aprendizaje, el desarrollo profesional y el compromiso Ético se relacionan con la enseñanza aprendizaje del área de estudios sociales en los estudiantes de Educación Básica “Ciudad de Loja ”; LAS LAJAS-Ecuador, Periodo lectivo 2014-2015.
Tesis
Gonzalez, Rogério Luciano Miziara. "Análise de lajes pela teoria das charneiras plásticas e comparação de custos entre lajes maciças e lajes treliçadas." Universidade de São Paulo, 1997. http://www.teses.usp.br/teses/disponiveis/18/18134/tde-20032018-103702/.
Full textThe main purpose of this work is to systematize the building rectangular compact slab calculation, using the yield line theory. The necessary formulation is presented. Deflections of reinforced concrete slabs are also discussed, making evident that cracking and time dependent effects are important parameters to be considered. Finally, a comparison with the elastic method for compact slabs design and with the lattice slab systems is presented, considering two examples of building floors, taking into account technical and financial (expenses) aspects of the results.
Lima, Henrique Jorge Nery de. "Análise experimental da punção de lajes lisas tipo Bubbledeck." reponame:Repositório Institucional da UnB, 2015. http://dx.doi.org/10.26512/2015.03.D.18978.
Full textSubmitted by Raquel Viana (raquelviana@bce.unb.br) on 2015-10-27T17:52:00Z No. of bitstreams: 1 2015_HenriqueJorgeNerydeLima.pdf: 6993717 bytes, checksum: 78b476f031b2b70c6f9092c00fcaecce (MD5)
Approved for entry into archive by Marília Freitas(marilia@bce.unb.br) on 2015-12-20T15:43:20Z (GMT) No. of bitstreams: 1 2015_HenriqueJorgeNerydeLima.pdf: 6993717 bytes, checksum: 78b476f031b2b70c6f9092c00fcaecce (MD5)
Made available in DSpace on 2015-12-20T15:43:20Z (GMT). No. of bitstreams: 1 2015_HenriqueJorgeNerydeLima.pdf: 6993717 bytes, checksum: 78b476f031b2b70c6f9092c00fcaecce (MD5)
Esta pesquisa avalia experimentalmente o comportamento da ligação laje-pilar, localizadas internamente à edificação em um sistema de lajes lisas de concreto armado, de uma recente técnica construtiva de lajes de concreto armado, denominada Bubbledeck. Essa técnica consiste em um método construtivo composto pela adição de esferas plásticas em lajes de concreto armado, uniformemente espaçadas entre duas telas de aço, com uso cada vez mais frequente em países como Holanda, Austrália, Estados Unidos, Canadá, Reino Unido e Dinamarca. Foram analisadas quatro modelos de lajes nesse estudo experimental, três lajes do tipo Bubbledeck e uma laje maciça de referência, todas as lajes possuem dimensões de 2500 x 2500 mm de comprimento, altura nominal com 280 mm, pilar circular com 300 mm de diâmetro e mesma taxa de armadura. Os parâmetros variados foram: método construtivo, utilização ou não de pré-laje; e utilização de armadura de cisalhamento. Os pontos analisados nos resultados experimentais foram: os deslocamentos verticais, deformações na superfície do concreto, deformações na armadura de flexão e cisalhamento, fissuração e o modo de ruptura de cada laje. Os dados experimentais foram comparados com os métodos teóricos estabelecidos em normas de projeto. As normas avaliadas foram: o ACI 318 (2011), o Eurocode 2 (2010) e a NBR 6118 (2014). Uma vez que nenhuma destas normas não tratam desse sistema construtivo de lajes Bubbledeck, foi proposta uma adaptação na determinação da área de concreto a ser considerada na seção do perímetro crítico. Verificou-se que o método construtivo não interferiu de forma considerável na resistência ao cisalhamento na ligação laje-pilar das lajes Bubbledeck e que a armadura de cisalhamento adotada mesmo conferindo maior ductilidade à laje, também não conferiu maior incremento de resistência à punção.
This research experimentally evaluates the behavior of slab-column connection, internally located at the building, in a reinforced concrete flat slabs system, a recent construction technique of reinforced concrete slabs, called Bubbledeck. This technique consists of new constructive method comprises the addition of plastic balls in reinforced concrete slabs, evenly spaced between two steel screens. Its use is increasingly common in countries like the Netherlands, Australia, USA, Canada, UK and Denmark. Four slabs models were analyzed in this experimental study (three Bubbledeck type and a reference solid), all of the slabs have dimensions of 2500 x 2500 mm length, nominal height of 280 mm, centered circular cross section column of 300 mm diameter and the same flexural reinforcement ratio. The varied parameters in Bubbledeck slabs were: construction method, use or not of pre-slab; and use of shear reinforcement. The points analyzed the experimental results were: vertical displacements, strains in the concrete surface deformations in the armor of bending and shear cracking and failure mode of each slab. The experimental data were compared with the theoretical methods established in design codes. The codes were evaluated: ACI 318 (2011), the Eurocode 2 (2010) and the NBR 6118 (2014). Since none of these codes do not address this constructive system Bubbledeck slabs, proposed an adaptation in determining the concrete area to be considered in the critical section perimeter. It was found that the construction method did not affect considerably the shear strength of the slab-column connection of Bubbledeck slabs and shear reinforcement adopted even giving greater ductility to the slab, also did not confer greater resistance to increase the punching.
Caixeta, Edielce Cristina. "Investigação experimental da fadiga em lajes de pontes com ou sem pré-lajes." Universidade de São Paulo, 2010. http://www.teses.usp.br/teses/disponiveis/3/3144/tde-20102010-151801/.
Full textConcrete bridge slabs, massive or pre-slabs, are structural elements susceptible to fatigue, due to loading applied to them. Pre-slabs, result of two different concretes, become even more susceptible to fatigue. This research presents the studies, tests and analysis of the results about the behavior of concrete bridge massive slabs or pre-slabs reinforced with steel bars and welded steel meshes due to fatigue loading. Axial testing in air of CA50 f10 mm in continuous bars and steel meshes were made in order to build the Wöhler Curve to the Brazilian conditions. Besides that, tests were made in 23 concrete slabs, 6 massive slabs and 17 preslabs, with several reinforcements arrangements, submitted to static and dynamic loading. The reinforcement configurations adopted in the slabs were based on the commonly used in these bridge elements in scale ½. One of main reasons that lead this experimental research development was the scarcity of data about the behavior of concrete slabs reinforced with rebars and welded mesh made in Brazil, submitted to cycle loading. Another reason was the lack of studies about the iteration between pre-slab and concrete cover. It was verified that no rupture was found in this region of the structure due to midspan cycle loading. The welding process caused loss of fatigue resistance.
Cavalcanti, Paulo de Sá Pereira. "Investigação experimental da fadiga ao cisalhamento em lajes de pontes com pré-lajes." Universidade de São Paulo, 2010. http://www.teses.usp.br/teses/disponiveis/3/3144/tde-28022011-170148/.
Full textA significant number of bridges have been built in the form of grids of pre-cast beams on which pre-slab are supported, with posterior concreting of concrete cover, completing the execution of the slabs. This construction process has been widely used in order to rationalize the construction without shoring, shortening considerably the time of construction and thereby reducing costs. However in developing the project, it is known that these slabs are elements highly susceptible to fatigue and, keeping in mind the existence of concrete in two stages (pre-slab and final cover) and different ages, doubts about the behavior of this interface with respect to dynamic loads acting over the lifetime are generated. The scarcity of studies and researches related to this issue led to the realization of this experimental work, in order to study the behavior of these elements subjected to fatigue loading and their final resistance in relation to the failure load before and after fatigue loading. Tests were made in 9 concrete slabs, 6 with usual surface roughness (salience of crushed aggregates 1) and 3 with low roughness (smoothing with wooden spatula). It was verified that no rupture due to fatigue loading were identified and the resistance of the slabs submitted to fatigue loading remained on the same level of those not fatigued, when carried to cracking at the end of the tests.
Menéndez, Ledo Mauricio. "Análise experimental à punção de lajes lisas tipo BubbleDeck com pilar interno." reponame:Repositório Institucional da UnB, 2016. http://repositorio.unb.br/handle/10482/21638.
Full textSubmitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2016-09-09T19:33:41Z No. of bitstreams: 1 2016_MauricioMenéndezLedo.pdf: 8763008 bytes, checksum: 447b2ea5dac1c91234df76acb1879ba6 (MD5)
Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2016-11-01T14:51:22Z (GMT) No. of bitstreams: 1 2016_MauricioMenéndezLedo.pdf: 8763008 bytes, checksum: 447b2ea5dac1c91234df76acb1879ba6 (MD5)
Made available in DSpace on 2016-11-01T14:51:22Z (GMT). No. of bitstreams: 1 2016_MauricioMenéndezLedo.pdf: 8763008 bytes, checksum: 447b2ea5dac1c91234df76acb1879ba6 (MD5)
Um sistema de lajes nervuradas relativamente recente é o sistema BubbleDeck, composto de esferas plásticas de polipropileno inseridas em lajes de concreto. Dentre as vantagens deste sistema pode-se destacar principalmente a redução do peso próprio se comparada à laje maciça, porém, como toda laje nervurada, cuidado especial deve ser dedicado à análise do cisalhamento das nervuras, além da punção na ligação laje / pilar. Nesta pesquisa foram ensaiadas experimentalmente quatro lajes lisas, sendo duas do tipo maciça e duas do tipo BubbleDeck, ensaiadas no Laboratório de Estruturas da Universidade de Brasília. Os modelos locais ensaiados simulam a ligação laje-pilar interno de uma edificação com carregamento simétrico. As dimensões dos modelos de laje foram de 2500 x 2500 mm e 280 mm de espessura com pilar circular centrado de 300 mm de diâmetro, utilizando mesma taxa de armadura de flexão para todos os modelos e concreto de 45 MPa. Foi avaliada a resistência à punção em lajes tipo BubbleDeck considerando a técnica construtiva deste tipo de laje (armadura de cisalhamento não ancorada à armadura de flexão e distribuição da armadura de punção padrão BubbleDeck) e comparada com lajes maciças considerando armadura de cisalhamento ancorada e com uma das distribuições especificadas pelas normas (distribuição em cruz). Os resultados obtidos nos ensaios foram analisados quanto a: deslocamentos verticais, deformações na superfície comprimida do concreto, deformações nas armaduras de flexão e cisalhamento, mapas de fissuração, e modo de ruptura das lajes. Foram comparadas com as cargas de ruptura as estimativas de carga última à punção pelo ACI 318 (2011), pelo EUROCODE 2 (2004) e pela NBR 6118 (2014). Para o cálculo do perímetro crítico das lajes BubbleDeck foi sugerida uma diminuição na área efetiva de concreto quando é interceptado pela zona dos vazios esféricos. Os resultados obtidos em laboratório evidenciaram que as lajes BubbleDeck atingiram cargas de ruptura aproximadamente 20% menores que as lajes maciças, e que o uso ou não de pré-laje não influenciou na resistência última a punção das lajes. Com as modificações de cálculo sugeridas nesta pesquisa, para as lajes BubbleDeck as normas ACI 318 (2011) e EUROCODE 2 (2004) foram as que melhor estimativa de cargas ultimas apresentaram. ________________________________________________________________________________________________ ABSTRACT
The BubbleDeck system is a relatively recent type of waffle slab being used, where polypropylene plastic balls are used embedded to the concrete slab. Among the advantages are the weight reductions, besides being a flat slab. However, special care should be devoted to the shear at the strips, besides the punching shear at the column/slab connection. In this research are experimentally evaluated four flat slabs, two of these are solid slabs and two are BubbleDeck type, tested in the structures laboratory at the University of Brasilia. The tested models correspond to interior column/slab connection of a building, with dimensions of 2500 x 2500 mm long, 280 mm thick, circular column with 300 mm diameter, the same flexural reinforcement ratio and concrete strength of 45 MPa. It was evaluated the punching shear resistance in BubbleDeck slabs type considering the construction technique of this type of slab (shear reinforcement not anchored to the reinforcement bending and standard BubbleDeck punching shear distribution) and compared to solid slabs considering anchored shear reinforcement and a distributions specified by the rules (distribution crosswise). The test results obtained were analyzed with respect to: vertical displacements of the slabs, deformations in the compressed surface of the concrete, deformations in flexural and shear reinforcement, cracking maps, and the slabs failure mode. The estimated punching shear last load according to ACI 318 (2011), EUROCODE 2 (2004) and NBR 6118 (2014) were evaluated. The results obtained in the laboratory showed that the BubbleDeck slabs reached last loads approximately 20% smaller than the solid slabs, and the use or not of pre-slab did not influence the last punching shear resistance. By the calculating adaptions suggested in this research, the standards ACI 318 (2011) and EUROCODE 2 (2004 ) were the best adapted, with good precision when estimating the strength of BubbleDeck slabs.
Tiano, Pasquale. "Magnetic dating of Vesuvian lavas." Thesis, University of Plymouth, 2001. http://hdl.handle.net/10026.1/2045.
Full textGurriet, Philippe C. (Philippe Charles). "Geochemistry of Hawaiian dredged lavas." Thesis, Massachusetts Institute of Technology, 1988. http://hdl.handle.net/1721.1/54327.
Full textSilvany, Tatiana Theophilo. "Deslocamentos transversais em lajes-cogumelo." Universidade de São Paulo, 1996. http://www.teses.usp.br/teses/disponiveis/18/18134/tde-14052018-110743/.
Full textFlat plates are structural systems that present some advantages when compared to slabs with beams. On the other hand, when beams are removed some problems can arise, such as slab deflections, global instability of the building and punching shear. This work deals with the flat plate deflections, comparing computed deflections using different procedures: crossing beam method, Rangan method and finite element method. Basic concepts for the calculation of these deflections, the cracking stage to be adopted in order to determine the stiffness and the effects of concrete creep and shrinkage using the ACI 209R-92 are presented. Three examples are developed. Based on the results, it is noticed that the computed deflections using different procedures depend on the esteemed stiffness, since the influence of cracking stage in the slab deflections is great. In the first two examples, the difference between the results calculated using the Rangan method (which adopts a standard cracking stage) and the finite element method (considering cracking) is very variable; the results differ within a range of 1% to 200%. The results calculated with two finite element program (which consider cracking by different ways) do not present differences greater than 14%.
Dawacairen. "Xizang huo fo de zheng zhi jiao se ji qi li shi bian qian = The political role of living Buddha in Tibet and their historical transformations /." click here to view the abstract and table of contents, 2000. http://net3.hkbu.edu.hk/~libres/cgi-bin/thesisab.pl?pdf=b15722636a.pdf.
Full textAlbuquerque, Nívea Gabriela Benevides de. "Comportamento das ligações de lajes lisas de concreto armado com pilares de borba sujeitas a excentricidades interna e externas." reponame:Repositório Institucional da UnB, 2014. http://repositorio.unb.br/handle/10482/17442.
Full textSubmitted by Ana Cristina Barbosa da Silva (annabds@hotmail.com) on 2014-12-18T15:00:31Z No. of bitstreams: 1 2014_NiveaGabrielaBenevidesdeAlbuquerque.pdf: 62275227 bytes, checksum: b47e61ad1a632a18dc73e98cd51ed5cc (MD5)
Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2014-12-29T17:14:09Z (GMT) No. of bitstreams: 1 2014_NiveaGabrielaBenevidesdeAlbuquerque.pdf: 62275227 bytes, checksum: b47e61ad1a632a18dc73e98cd51ed5cc (MD5)
Made available in DSpace on 2014-12-29T17:14:09Z (GMT). No. of bitstreams: 1 2014_NiveaGabrielaBenevidesdeAlbuquerque.pdf: 62275227 bytes, checksum: b47e61ad1a632a18dc73e98cd51ed5cc (MD5)
São apresentados os resultados de uma pesquisa experimental sobre punção em ligações de lajes lisas de concreto armado com pilares de borda considerando-se a transferência de momentos e cisalhamento não uniforme devido às excentricidades no apoio, especialmente utilizando excentricidades externas, dada a necessidade de maiores diretrizes normativas. Foram ensaiados 13 modelos locais de 2.350 mm x 1.700 mm de um pavimento de concreto armado com 180 mm de espessura em torno do pilar de borda com seção transversal quadrada de 300 mm x 300 mm de lado, com projeções na base para imposição das excentricidades que reproduziram uma porção de laje. A posição do apoio sob o pilar determinou a excentricidade – variável principal entre os modelos – sendo também controladas as condições de contorno e taxas de armadura de flexão. Parâmetros adicionais como armadura de cisalhamento (studs) e de torção (estribos) foram investigados em 4 desses modelos. Os resultados obtidos com os ensaios possibilitaram avaliar comparativamente o comportamento dos modelos quanto às deformações nas armaduras de flexão, cisalhamento e torção e do concreto, deslocamentos verticais e horizontais, padrão de fissuração, modos de ruptura e cargas últimas das lajes. São apresentadas as previsões da capacidade última das ligações ensaiadas conforme as prescrições das normas correntes, em particular o EC2 (2004), no qual é baseada a norma brasileira e o ACI 318 (2011), incluindo também estimativas do banco de dados formado a fim de mostrar uma visão mais ampla do problema. Uma metodologia simplificada de cálculo para obtenção da carga última foi desenvolvida na tentativa de auxiliar a compreensão do modo pelo qual ocorre a transferência das cargas e momentos na ligação entre a laje e o pilar de borda quando submetido às excentricidades. Por fim, uma simulação numérica é reproduzida, correlacionando-se os dados monitorados em laboratório aos resultados provenientes da modelagem em elementos finitos visando obter a distribuição do esforço cortante no perímetro crítico. De posse dos resultados calibrados e validados, são propostas mudanças nos valores de k do EC2 (2004) para que as previsões de capacidade resistente à punção em ligações de borda forneçam valores mais próximos aos experimentais. ____________________________________________________________________________________ ABSTRACT
This work presents the punching results of an experimental research on reinforced concrete flat slab-edge column connections considering the moment transferring and uneven shear due to support eccentricities, especially outward ones, since it’s been recognized the need for further guidelines on code provisions, mainly with respect to the design process using outward eccentricities. Thirteen local models were tested, reproducing a 2,350 mm x 1,700 mm portion of a 180 mm thick reinforced concrete slab adjacent to a 300 mm x 300 mm squared edge column, provided with an 830 mm of total height projection at the base for the imposition of eccentricities. The position of the support under the column has determined the eccentricity – the main variable among models. Boundary conditions and flexural geometrical ratio have also been controlled. Additional parameters such as shear reinforcement (studs) and torsional reinforcement (stirrups) were investigated in four of these models. The results obtained from the experimental tests comparatively show the models’ behaviour with relation to its strain capacity on the flexural, shear and torsional reinforcement and concrete surface, vertical and horizontal displacements, crack pattern, failure modes and ultimate loads. Predictions of ultimate capacity of the tested connections are presented following the requirements of current standards, particularly EC2 (2004), on which is based the Brazilian standard and ACI 318 (2011), also including estimation of a database to show an overview of these scenarios. A simplified calculation methodology for obtaining the ultimate load was developed focusing on a greater comprehension of the way loads and moments are transferred from the slab to the edge column when subjected to eccentricities. Finally, a numerical simulation is reproduced, by matching the data based on lab monitoring to the results from finite element modelling in order to obtain the distribution of the critical shear perimeter. With those calibrated and validated results, changes in the values of k from EC2 (2004) for punching predictions of edge connections are proposed, providing closer values to the test ones.
Alejandro, Ceballos Manuel. "Análise experimental à punção em lajes tipo Bubbledeck com armadura de cisalhamento." reponame:Repositório Institucional da UnB, 2017. http://repositorio.unb.br/handle/10482/24276.
Full textSubmitted by Raiane Silva (raianesilva@bce.unb.br) on 2017-07-17T17:40:48Z No. of bitstreams: 1 2017_ManuelAlejandroCeballos.pdf: 22588428 bytes, checksum: 72b575e3a5a69365b10f9d30c1914493 (MD5)
Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2017-08-24T20:14:30Z (GMT) No. of bitstreams: 1 2017_ManuelAlejandroCeballos.pdf: 22588428 bytes, checksum: 72b575e3a5a69365b10f9d30c1914493 (MD5)
Made available in DSpace on 2017-08-24T20:14:30Z (GMT). No. of bitstreams: 1 2017_ManuelAlejandroCeballos.pdf: 22588428 bytes, checksum: 72b575e3a5a69365b10f9d30c1914493 (MD5) Previous issue date: 2017-08-24
Esta pesquisa avalia o comportamento experimental à punção da ligação laje pilar interno numa edificação submetida a carregamento simétrico usando lajes Bubbledeck reforçadas ao cisalhamento mediante utilização de Pinos (Studs) e treliças entre as nervuras. As seis lajes ensaiadas (cinco lajes do tipo Bubbledeck e uma laje maciça), foram confeccionadas no laboratório de estruturas da UnB e apresentaram as seguintes caraterísticas: lajes com lados de 2500 x 2500 mm e com espessura de 280 mm, moldadas com concreto de resistência em torno de 33 MPa, e apoiadas em segmentos de pilar de seção circular com 300 mm de diâmetro e mesma taxa de armadura. Os parâmetros medidos no desenvolvimento deste programa experimental foram, os deslocamentos verticais, deformações na superfície do concreto, deformações na armadura de flexão e cisalhamento (pinos e treliças), alem da inspeção visual do modo de ruptura e a fissuração de cada laje, os quais foram comparados e analisados com os métodos teóricos estabelecidos nas seguintes Normas: ACI 318 (2014), Eurocode 2 (2004), NBR 6118 (2014) e fib MC2010 (2010). Tudo isto permitiu estudar a influência de parâmetros como: o uso de armadura de cisalhamento nas nervuras (treliças), e o uso de armadura de cisalhamento (studs) na resistência à punção da ligação laje-pilar. Já que nenhuma dessas normas considera os vazios deixados pelas esferas no cálculo da resistência à punção em lajes Bubbledeck, foi proposta uma adaptação na determinação da área de concreto a ser considerada na seção do perímetro crítico. Verificou-se que as adaptações feitas no fib MC2010 (2010) apresentaram os valores de carga ultima de punção mais próximos dos resultados experimentais, e que o uso de treliças de 60_ ou 45_ geraram um incremento na resistência das lajes testadas ao serem comparadas com a laje Bubbledeck de referência.
This paper evaluates the experimental behavior of punching shear correspond to interior column/slab connection of a building subject to symmetrical loading, using Bubbledeck slabs, reinforced to shear using Studs and trusses between the ribs. The six slabs tested (five Bubbledeck-type slabs and one massive slab) were made in the UnB structures laboratory and had the following properties: slabs with sides of 2500 x 2500 mm and 280 mm thick, molded with resistance concrete around 33 MPa, and supported on circular column with 300 mm diameter and same flexural reinforcement ratio . The parameters measured in the development of this experimental program included: vertical displacements, deformations on the concrete surface, deformations in the flexural reinforcement and deformations im shear reinforcement (studs and trusses), cracking and rupture mode of each slab, which were compared and analyzed with the theoretical methods established in the following Standards: ACI 318 (2014), Eurocode 2 (2004), NBR 6118 (2014) and fib MC2010 (2010). This allowed the opportunity to study the influence of parameters such as: the use of shear reinforcement in the ribs (trusses), and the use of shear reinforcement, in the punching shear resistance of the column/slab connection. Given that none of these norms considers the voids left by the spheres in the calculation of the punching shear resistance in Bubbledeck slabs, an adjustment was proposed in the determination of the concrete area to be considered in the critical perimeter section. It was found that the use of 60_ or 45 _ trusses generated an increase in the resistance of the slabs tested when compared to the reference Bubbledeck slab, and that while the modified standards were estimated, fib MC2010 (2010) showed the highest values the experimental results.
Kerkelä, J. (Joni). "Pilvipalveluiden haavoittuvuudet laaS -palvelumuodossa." Bachelor's thesis, University of Oulu, 2016. http://urn.fi/URN:NBN:fi:oulu-201601201070.
Full textMontoya, V. Karol. "Club de canotaje Laja." Tesis, Universidad de Chile, 2009. http://www.repositorio.uchile.cl/handle/2250/115800.
Full textNicácio, Wanderley Gustavo. "Comportamento à punção de lajes de concreto armado tipo bubbledeck." reponame:Repositório Institucional da UnB, 2018. http://repositorio.unb.br/handle/10482/32546.
Full textSubmitted by Fabiana Santos (fabianacamargo@bce.unb.br) on 2018-08-27T21:05:27Z No. of bitstreams: 1 2018_WanderleyGustavoNicácio.pdf: 30765952 bytes, checksum: 81e5701ccda6742875f7ac2cbcce6af7 (MD5)
Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2018-08-31T16:53:40Z (GMT) No. of bitstreams: 1 2018_WanderleyGustavoNicácio.pdf: 30765952 bytes, checksum: 81e5701ccda6742875f7ac2cbcce6af7 (MD5)
Made available in DSpace on 2018-08-31T16:53:41Z (GMT). No. of bitstreams: 1 2018_WanderleyGustavoNicácio.pdf: 30765952 bytes, checksum: 81e5701ccda6742875f7ac2cbcce6af7 (MD5) Previous issue date: 2018-08-27
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES).
Ao longo dos anos foram desenvolvidos novos sistemas de lajes com vazios moldados a partir de formas de plástico, com destaque para as lajes BubbleDeck (BD). Nestes sistemas, o conceito consiste em colocar formas de plástico reciclado oco entre duas malhas de armadura, no centro de uma laje de concreto. A laje BD é comumente associada ao sistema de lajes lisas, que tem como uma de suas preocupações do ponto de vista de dimensionamento a ruptura localizada por punção na ligação laje-pilar. Esta pesquisa avalia experimentalmente o comportamento à punção, num sistema de lajes lisas de concreto armado dos tipos BD e maciça, localizadas internamente à edificação e submetidas a carregamento simétrico. No total foram ensaiados 11 modelos com dimensões de 2500 x 2500 mm de comprimento base, altura nominal de 280 mm, pilares circulares centrados com dimensão de 300 mm de diâmetro e mesma taxa da armadura de flexão, variando-se: a utilização de pré-laje, a distribuição das armaduras de cisalhamento e sua respectiva forma de ancoragem. Os resultados obtidos com os ensaios possibilitaram avaliar comparativamente o comportamento dos modelos quanto aos deslocamentos verticais, deformação específica no concreto, no aço e na armadura de cisalhamento, carga última, fissuração, superfície e modo de ruptura. São apresentadas as previsões da capacidade última das ligações ensaiadas conforme as prescrições adaptadas das normas ACI 318 (2014), Eurocode 2 (2004) e ABNT NBR 6118 (2014), incluindo também as recomendações do fib Model Code 2010 (2012). De posse de todos resultados, foi proposta uma adequação da NBR 6118 (2014) para o caso de punção em lajes BD, de forma a apresentar previsões mais próximas dos resultados experimentais. Por fim, foi verificada a viabilidade da utilização do software FEMIX 4.0 para representar o comportamento de lajes BubbleDeck.
Various types of voided concrete slabs have been used throughout the years, especially the BubbleDeck slabs (BD). In these systems, the concept consists of placing forms of hollow plastic balls between the tensile and compressive reinforcement meshes, in the middle of the concrete slab. The BD slab is commonly associated with the flat slab system, which warns the designer about a punching shear failure at slab-column connections. This research experimentally evaluates the behavior in punching shear in systems of BD type flat slabs and solid slabs, simulating an inner slab-column connection of a building and submitted to symmetrical loading. In total, 11 models measuring 2500 x 2500 mm in length, nominal height of 280 mm, supported on centered circular column with a 300 mm diameter and the same flexural reinforcement ratio, varying the use of precast panel, the distribution of shear reinforcement and its anchorage. The results obtained from the experimental tests are comparatively shown with respect to the slabs vertical displacement, the concrete, flexural and shear reinforcement strains, ultimate loads, cracking patterns, surface and failure modes. Predictions of ultimate capacity of the tested connections are calculated according to the requirements of the ACI 318 (2014), Eurocode 2 (2004) and ABNT NBR 6118 (2014) standards, and the fib Model Code 2010 (2012). With these results, it was proposed an amendment to of NBR 6118 (2014) for the case of punching in BD slabs, in order to match the experimental results. Finally, the feasibility of the FEMIX 4.0 software to numerically simulate the behavior of BubbleDeck slab was verified.
Valdivia, Alatrista Carla Marlene. "Una mirada territorial en la planificación sostenible de las ciudades urbano-rurales. Caso: el territorio de Lamas, región de San Martín." Pontificia Universidad Católica del Perú, 2019. http://hdl.handle.net/20.500.12404/16927.
Full textTrabajo de investigación
Albuquerque, Elaine Jaricuna Pereira de. "Punção em lajes lisas com armadura de cisalhamento e pilares de centro retangulares." reponame:Repositório Institucional da UnB, 2010. http://repositorio.unb.br/handle/10482/8597.
Full textSubmitted by Luiza Moreira Camargo (luizaamc@gmail.com) on 2011-06-21T19:44:00Z No. of bitstreams: 1 2010_ElaineJaricunaPereiradeAlbuquerque.pdf: 4245469 bytes, checksum: 610bbb590bbcd948f5655fee3c0e8102 (MD5)
Approved for entry into archive by Guilherme Lourenço Machado(gui.admin@gmail.com) on 2011-06-22T14:08:53Z (GMT) No. of bitstreams: 1 2010_ElaineJaricunaPereiradeAlbuquerque.pdf: 4245469 bytes, checksum: 610bbb590bbcd948f5655fee3c0e8102 (MD5)
Made available in DSpace on 2011-06-22T14:08:53Z (GMT). No. of bitstreams: 1 2010_ElaineJaricunaPereiradeAlbuquerque.pdf: 4245469 bytes, checksum: 610bbb590bbcd948f5655fee3c0e8102 (MD5)
São analisadas experimentalmente 8 (oito) modelos locais de ligação laje lisa/pilar retangular de centro com armadura de cisalhamento tipo stud. Os modelos são constituídos por lajes quadradas com 2500 mm de lado e 180 mm de espessura, com pilar central retangular de seção transversal de 200 mm x 400 mm e comprimento de 800 mm acima e 600 mm abaixo da laje. A armadura de cisalhamento das lajes foi constituída por uma distribuição “radial” de studs com diâmetro de 8 mm. As principais variáveis dos ensaios foram a quantidade de camadas dessa armadura de cisalhamento (studs) e a orientação da direção da flexão da laje em relação aos lados do pilar central retangular. Foram realizadas comparações entre os resultados experimentais e as prescrições normativas estabelecidas pela NBR 6118:2003 e por alguns códigos internacionais de referência, como o ACI 318M-08 e o EUROCODE 2:2004, para verificar se as formulações desses códigos são adequadas. Foi verificada a influência dos studs no aumento da rigidez da ligação, na alteração do padrão de fissuração, e na forma do cone de ruptura. As comparações mostraram que o EUROCODE 2:2004 forneceu melhores estimativas e a favor da segurança, em relação aos demais códigos avaliados. A NBR 6118:2003 apresentou boas estimativas, enquanto o ACI 318M-08 mostrou-se mais conservador, em parte por ter em sua formulação limitações para resistência característica do concreto e tensão de escoamento do aço. _______________________________________________________________________________ ABSTRACT
Eight flat slab/central rectangular columns models were tested. The slabs had a stud type shear reinforcement and were 2500 mm square and 180 mm thick, with 200 mm x 400 mm cross-section columns, and 800 mm length above and 600 mm length below the slab. The 8 mm diameter studs of the shear reinforcement were radially distributed. The main variables of the tests were the studs shear reinforcement number of layers and the bending direction in relation to the rectangular columns sides. The influence of the studs on the increase of the rigidity of the connection and on the alteration of the crack pattern and on the shape of the rupture cone was verified. Comparisons were made between the experimental and the estimations by the Brazilian Code NBR 6118:2003 and by ACI 318M-08 and Eurocode 2:2004. Better conservative estimates were provided by EUROCODE 2:2004. NBR 6118:2003 presented good estimations, while ACI 318M-08 was the most conservative, due to its limitations on how the concrete and the steel strengths are dealt.
Gomes, Helder Pontes. "Puncionamento em lajes lisas protendidas com pilares de extremidade e momentos desbalanceados nas duas direções." reponame:Repositório Institucional da UnB, 2010. http://repositorio.unb.br/handle/10482/8942.
Full textSubmitted by wiliam de oliveira aguiar (wiliam@bce.unb.br) on 2011-07-05T14:52:55Z No. of bitstreams: 1 2010_HelderPontesGomes.pdf: 9122556 bytes, checksum: b841c45ad5e59227429fd3fd11d66744 (MD5)
Approved for entry into archive by Guilherme Lourenço Machado(gui.admin@gmail.com) on 2011-07-06T13:07:17Z (GMT) No. of bitstreams: 1 2010_HelderPontesGomes.pdf: 9122556 bytes, checksum: b841c45ad5e59227429fd3fd11d66744 (MD5)
Made available in DSpace on 2011-07-06T13:07:17Z (GMT). No. of bitstreams: 1 2010_HelderPontesGomes.pdf: 9122556 bytes, checksum: b841c45ad5e59227429fd3fd11d66744 (MD5)
São apresentados neste trabalho resultados experimentais dos ensaios de dezesseis modelos locais de ligação laje lisa protendida-pilar de extremidade. Buscou-se por meio desses ensaios avaliar a influência da relação do momento fletor M/V (momento fletor nas duas direções ortogonais dividido pela força cortante), da relação C1/d (dimensão perpendicular do pilar dividia pela altura útil da laje), da presença de overhang e do nível de protensão na resistência à punção. Foram realizadas também comparações entre os resultados experimentais e as previsões da NBR 6118:2003 e de outras duas normas: ACI 318M-02 e EUROCODE 2:2001. As análises realizadas indicaram que o acréscimo de tensão nos cabos está associado ao tipo de carregamento aplicado. As deformações das barras da armadura passiva foram bastante influenciadas pelo tipo de carregamento, embora esta influência tenha se concentrado nas faixas do pilar, mais precisamente na região próxima a este. As deformações da superfície inferior das lajes dos modelos sofreram influência da disposição dos cabos de protensão. A presença de overhang aumenta a rigidez da ligação, influencia no padrão de fissuração e na forma do cone de ruptura. As comparações com as normas mostraram que o ACI 318M-02 (média: 2,90) apresentou o desempenho mais conservador dentre todas as outras normas avaliadas. Este elevado conservadorismo se deve ao fato desta norma ter em sua formulação limitações para o cálculo à punção, em especial em pilares de extremidade. O EUROCODE 2:2001, com média igual a 1,60, foi o texto oficial menos conservador. A norma brasileira (média: 2,46) obteve resultados bastantes conservadores, principalmente para o caso de transferências de momentos em duas direções. Todas as normas analisadas mostraram-se não estarem ajustadas para relação C1/d maior que 2,0, apenas o EUROCODE 2:2001 se mostrou capaz de boas previsões de carga de ruptura para os casos da contribuição do overhang na tensão resistente para ligações laje/pilar de borda com transferência de momentos em duas direções ortogonais. As modificações propostas se mostraram adequadas para a previsão de cargas de ruptura nos casos ensaiados, reduzindo o conservadorismo e tronando, principalmente nos casos do ACI 318M-02 (média: 1,32) e da NBR 6118:2003 (média: 1,37), as formulações mais homogêneas e próximas do fenômeno observado. ________________________________________________________________________________ ABSTRACT
Sexteen local post-tensioned flat slab-edge column conections with unbonded tendons were tested and analyzed in this work. The intent was evaluate the influence of the bending moment/shear force (M/V), C1/d relation, the level of post tension, the presence of overhang and the moment transfer on both ortogonal directions in the pushing shear resistence in those connections. Were made comparisons of those results with analytical predictions established by NBR 6118:2003 and two others international codes: ACI 318M-02 and EUROCODE 2:2001; and modifications was proposed to improve those performances. The analysis of the tension of the tendons shows that increase of the tensions during the test is directly related with the applied load. Instrumented bars of the reinforcement showed that the applied loads have much influence on deformations and that the pushing shear phenomenon is restricted to areas closer to the column. The deformation of the inferior surface of the concrete around the connection was influenced by the arrangement of the tendons and by the presence of the overhang. The presence of the overhang enhances the connection rigidity and influence the standard of cracking and the shape of the truncated cone of failure. The carried out analysis of the codes showed that the ACI 318M-02 (average: 2,90) was the more conservative code among those studied. This high conservatism happens because of the restrictions that the American code imposes to calculation of the slab-edge columns connections. The code that had better performance for connections tested was EUROCODE 2:2001 (average: 1,60). The Brazilian code, NBR 6118:2003, was fairly conservative (average: 2,46), particularly in the cases with moment transfer on both orthogonal directions. All codes analyzed are not be adjusted to range of C1/d larger than 2,0 and only EUROCODE 2:2001 achieved god results on predict the failure load in cases of the contribution of the overhang to the pushing shear resistance and when the connection was submitted to moment transfer in both orthogonal directions. The proposed modifications on the codes’ formulations were successful to predict the failure load, reducing the conservatism and, especially to ACI 318M-02 (average: 1,32) and NBR 6118:2003 (average: 1,37), leading the formulations to be more homogeneous and closer to the observed phenomenon.
Feliciano, Fabio Matias Honorio. "Punção em lajes lisas de concreto armado com pilares de borda e excentricidade externa." reponame:Repositório Institucional da UnB, 2011. http://repositorio.unb.br/handle/10482/9354.
Full textSubmitted by Gabriela Ribeiro (gaby_ribeiro87@hotmail.com) on 2011-09-02T17:48:51Z No. of bitstreams: 1 2011_FabioMatiasHonorioFeliciano.pdf: 4680615 bytes, checksum: 3fbf6ec0242a8bc3f7a11ad7cac01019 (MD5)
Approved for entry into archive by Repositorio Gerência(repositorio@bce.unb.br) on 2011-10-03T12:09:58Z (GMT) No. of bitstreams: 1 2011_FabioMatiasHonorioFeliciano.pdf: 4680615 bytes, checksum: 3fbf6ec0242a8bc3f7a11ad7cac01019 (MD5)
Made available in DSpace on 2011-10-03T12:09:58Z (GMT). No. of bitstreams: 1 2011_FabioMatiasHonorioFeliciano.pdf: 4680615 bytes, checksum: 3fbf6ec0242a8bc3f7a11ad7cac01019 (MD5)
Embora diversas vantagens – construtivas e/ou arquitetônicas – sejam atribuídas às lajes lisas, a continuidade entre vãos consecutivos adotada em projetos multipavimentos faz da ligação laje-pilar uma região crítica, dado à concentração de tensões presente nesta região. Quando se adicionam carregamentos verticais e/ou horizontais, bem como a transmissão de momentos devido à imposição de excentricidades no apoio, esses efeitos são ainda mais pronunciados nos painéis externos. Nas normas de projeto, há a preocupação de incluir recomendações que certifiquem um comportamento seguro de ligações de lajes com pilares de borda submetidos a carregamentos excêntricos, embora estudos específicos ainda sejam bastante escassos, principalmente com relação a excentricidades externas. Dessa forma, para investigar o comportamento estrutural das ligações entre a laje e o pilar de borda foram ensaiados quatro modelos, que tiveram como variável a relação entre momento fletor e força cortante (relação M/V) na ligação, obtida pela variação da excentricidade de apoio em relação ao eixo do pilar, a saber: 300 mm (interna), centrada (referência) e 300 mm e 400 mm (externa). Os modelos estruturais consistiram da união de uma laje de dimensões 1700 mm x 2350 mm x 180 mm, com taxa de armadura de 0,75% e altura útil de 152 mm, a um pilar com 830 mm de altura e seção transversal quadrada (300 mm x 300 mm), dotado de uma projeção transversal de 650 mm para imposição das excentricidades no apoio. Os resultados foram analisados quanto ao comportamento de cargas últimas, deformações específicas na armadura, deformações específicas no concreto, deslocamentos verticais, rotação nos pilares e mapa de fissuração. Todos os modelos romperam por punção. As estimativas das normas ABNT NBR 6118:2003, ACI 318:2008 e EUROCODE 2:2004, para as cargas de ruptura, apontaram para uma necessidade de revisão do tratamento das normas para pilares de borda levando em consideração a excentricidade externa no apoio. _________________________________________________________________________________ ABSTRACT
Although several advantages – constructive and/or architectural - are assigned to flat slabs, the continuity between consecutive spans that is taken into multifloors buildings turns the slab-column connection into a critical region, due to the stress concentration present in this region. When it’s added vertical and/or horizontal loads and moments transferring due to the imposition of eccentricities at support, these effects are even more pronounced on external panels. On codes, there are concerns on including recommendations to certify safe behavior of slabs-edge columns connections subjected to eccentric loads, although specific studies are still rather scarce, especially related to outward eccentricities. Thus, to investigate the structural behavior of slabs-edge columns connections, four individual models were tested fixing as variable the ratio between bending moment and shear force (M/V) defined in terms of eccentricity of support, denoted as: 300 mm (inward), center (reference) and 300 mm and 400 mm (outward). Structural models consisted on slabs with dimensions of 1700 mm x 2350 mm x 180 mm with reinforcement ratio of 0.75% and 152 mm effective depth, connected with a column of 830 mm height and squared cross section (300x300 mm), equipped with a 650 mm projection to imposition of eccentricities at support. The results were analyzed in relation to the behavior of ultimate loads, strain in reinforcement, strain in concrete, vertical deflection, column rotations and crack pattern. All models failure by punching. The estimates of ABNT NBR 6118:2003, ACI 318:2008 and EUROCODE 2:2004, for the ultimate loads, indicate the need for revision of standards on the treatment of edge columns.
Moraes, Neto Bernardo Nunes de. "Comportamento à punção de lajes lisas em concreto reforçado com fibras de aço sob carregamento simétrico." reponame:Repositório Institucional da UnB, 2013. http://repositorio.unb.br/handle/10482/13487.
Full textSubmitted by Alaíde Gonçalves dos Santos (alaide@unb.br) on 2013-07-04T12:30:19Z No. of bitstreams: 1 2013_BernardoNunesdeMoraesNeto.pdf: 20442301 bytes, checksum: a9cf8faa1ef7e12dfba847eb6413eecb (MD5)
Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2013-07-04T13:31:15Z (GMT) No. of bitstreams: 1 2013_BernardoNunesdeMoraesNeto.pdf: 20442301 bytes, checksum: a9cf8faa1ef7e12dfba847eb6413eecb (MD5)
Made available in DSpace on 2013-07-04T13:31:15Z (GMT). No. of bitstreams: 1 2013_BernardoNunesdeMoraesNeto.pdf: 20442301 bytes, checksum: a9cf8faa1ef7e12dfba847eb6413eecb (MD5)
O presente estudo avalia o comportamento da ligação laje x pilar de lajes reforçadas com fibras de aço, localizada internamente à edificação e submetida a carregamento simétrico. Para este fim, realizaram-se testes experimentais e análises que discutiram a performance de alguns códigos de projeto e de modelos teóricos em prescrever a resistência última à punção de lajes reforçadas com fibras de aço. No tocante ao estudo experimental, foram realizados 8 testes de punção até a ruína, sendo 2 lajes de referência e 6 de concreto reforçado com fibras de aço, CRFA. A dimensão das peças foi de 2550 x 2550 x 150 mm3 e a ligação laje x pilar foi simulada por uma placa de aço de 200 x 200 x 50 mm3 em contato com a laje. As variáveis avaliadas foram: a resistência à compressão do concreto, fcm, 50 e 70 MPa e a quantidade de fibra adicionada à massa de concreto, Vf, 0, 60, 75 e 90 kg/m3. No que diz respeito às lajes de CRFA, uma das particularidades destas peças foi a utilização de armaduras de flexão apenas em uma região próxima à área carregada. Entretanto, nas questões de cálculo, as taxas de armadura, ?s, destas lajes foram as mesmas apresentadas pelas lajes de referência (armada em toda a sua extensão), visto que as recomendações normativas sugerem que o valor de ?s seja obtido sobre uma largura preestabelecida da laje. Nas análises dos códigos de projeto, foram avaliadas as prescrições do ACI 318 (2008), do CEB-FIP (1991), do EC2 (2004), da NBR 6118 (2003) e do CEB-FIP (2010). No que se refere aos modelos teóricos, discutiram-se as propostas de NARAYANAN e DARWISH (1987), de SHAABAN e GESUND (1994), de HARAJLI et al. (1995), de HOLANDA (2002), de CHOI et al. (2007), de MUTTONI e RUIZ (2010) e de HIGASHIYAMA et al. (2011). As referidas análises, além de avaliarem a dispersão e o nível de conservadorismo dos resultados, também os classificam segundo uma adaptação do critério de penalidade proposto por COLLINS (2001), o Demerit Points Classification - DPC. Por fim, com o intuito de contribuir ao conhecimento do dimensionamento à punção de lajes lisas reforçadas com fibras de aço, o presente trabalho apresenta uma proposta de cálculo com base na formulação de MUTTONI (2008), a qual estabelece o valor da resistência à punção segundo a Critical Shear Crack Theory. Para este propósito, foi discutida a relação carga x rotação e o critério de ruína das lajes reforçadas com fibras. Na sequência, também foi abordada uma proposta, a qual se baseia nos estudos de MUTTONI e RUIZ (2010) e adota a lei constitutiva tensão x abertura de fissura sugerida pelo CEB-FIP (2010), para estabelecer a parcela de contribuição da fibra de aço na resistência à punção. _______________________________________________________________________________________ ABSTRACT
In the present dissertation the behaviour of the column-slab connection interior of a building is investigated. Symmetric load conditions are assumed for this connection and a special focus is given in slabs made by steel fibre reinforced concrete (SFRC). For this purpose, experimental programs were carried out, and from these results and from a data base that collects the relevant results found in specialized bibliography, the predictive performance of the most reputed theoretical models for the prediction of the punching resistance of steel fibre reinforced concrete slabs was assessed. The experimental program was composed by eight slabs, two of them without steel fibres (reference slabs), and the remaining six slabs were made with SFRC. All the slabs have dimensions of 2550 x 2550 x 150 mm3, and the column-slab connection was simulated by a steel plate of 200 x 200 x 50 mm3 in direct contact with the slab. In this experimental program the influence of the following variables on the punching behaviour of the tested slabs was investigated: concrete strength class (average compressive strength, fcm, of 50 and 70 MPa); content of fibres added to the concrete (0, 60, 75 and 90 kg/m3). In the tested slabs, in an attempt of providing conditions for punching failure mode, conventional longitudinal tensile steel bars were disposed in the centre of the slab, close to the loaded area. The predictive performance of the formulations available in the following design guidelines was assessed: ACI 318 (2008), CEB-FIP (1991), EC2 (2004), NBR 6118 (2003), and CEB-FIP (2010). The accuracy of the following theoretical models was also investigated: NARAYANAN and DARWISH (1987), SHAABAN and GESUND (1994), HARAJLI et al. (1995), HOLANDA (2002), CHOI et al. (2007), MUTTONI e RUIZ (2010), and HIGASHIYAMA et al. (2011). The performed analyzes have covered the dispersion of the results, level of accuracy of the predictions of these models, and the Demerit Points Classification (DPC) proposed by COLLINS (2001). Finally, based on the formulation proposed by MUTTONI (2008), a new approach is proposed to estimate the punching resistance of SFRC slabs according to the Critical Shear Crack Theory. For this aim, the load-rotation relationship, and the failure criterion of SFRC slabs during the loading process were determined. Like the proposal of MUTTONI and RUIZ (2010), in the present approach the fibre reinforcement contribution was simulated by the stress-crack width but now adopting recommendations of CEB-FIP (2010).
Dumaresq, Gustavo Leite. "Análise de pós-puncionamento em lajes lisas de edifícios em concreto armado." reponame:Repositório Institucional da UnB, 2008. http://repositorio.unb.br/handle/10482/5187.
Full textSubmitted by Suelen Silva dos Santos (suelenunb@yahoo.com.br) on 2009-09-17T17:39:31Z No. of bitstreams: 1 2008_GustavoLeiteDumaresq.pdf: 3995220 bytes, checksum: bc24ad1d05b661bf5d51aafbceac35cf (MD5)
Approved for entry into archive by Gomes Neide(nagomes2005@gmail.com) on 2010-07-05T19:51:19Z (GMT) No. of bitstreams: 1 2008_GustavoLeiteDumaresq.pdf: 3995220 bytes, checksum: bc24ad1d05b661bf5d51aafbceac35cf (MD5)
Made available in DSpace on 2010-07-05T19:51:19Z (GMT). No. of bitstreams: 1 2008_GustavoLeiteDumaresq.pdf: 3995220 bytes, checksum: bc24ad1d05b661bf5d51aafbceac35cf (MD5) Previous issue date: 2008-10
Foi avaliado o comportamento pós puncionamento de edifícios em lajes lisas de concreto armado, como conseqüência da perda total ou parcial da capacidade resistente em ligações susceptíveis a rupturas por punção. Foram analisados três exemplos de estruturas de concreto armado, tendo sido empregado o software comercial para projeto de estruturas de concreto armado TQS (versão 13). A resistência à punção das ligações laje / pilar foram verificadas utilizando-se as normas NBR 6118: 2003, EUROCODE 2:2002 e ACI 318M: 2005. Para o cálculo das armaduras de combate ao colapso progressivo, foram utilizadas as recomendações da NBR 6118:2003, do CEB-FIP MC90:1993, e pelo processo proposto por MELO (1990). Utilizou-se também o Método das Linhas de Ruptura para verificar a contribuição da armadura de flexão presente no pavimento no comportamento pós puncionamento do pavimento após a simulação da ruptura por punção de uma das ligações laje-pilar. No primeiro exemplo constatou-se que, segundo as normas EUROCODE 2:2002 e NBR 6118:2003, no caso de uma ruptura eventual por punção na ligação laje/pilar P2, a ligação P3 não suportaria aos novos esforços e romperia por punção, podendo assim levar toda estrutura ao colapso. No segundo exemplo, observou-se que se houvesse a ruptura por punção nas ligações P2 e P14, as ligações P3 e P15 viriam também a romper, segundo as três normas, permitindo a ocorrência de colapso progressivo da estrutura. Já no terceiro exemplo conclui-se que a estrutura não é susceptível a ocorrência de colapso progressivo, pois as ligações mais solicitadas não apresentaram indícios de propagação de novas rupturas por punção nas ligações. A análise dos três exemplos utilizando o Método das Linhas de Ruptura mostrou que as estruturas possuem uma reserva de resistência à flexão que dificultaria a ocorrência de colapso progressivo nestas estruturas, já que foram encontradas cargas resistentes últimas nos pavimentos superiores às cargas atuantes. _______________________________________________________________________________ ABSTRACT
The post punching behavior of a reinforced concrete flat slab building was investigated, as consequence of punching failures resulting in partial or total residual resistance of the connections. Three buildings were analyzed using the Brazilian software TQS (13th version). The connections punching resistances were checked using Brazilian Code NBR 6118: 2003, EUROCODE 2:2002 and ACI 318M: 2005. The Brazilian Code NBR 6118: 2003, the CEBFIP MC90:1993 and a process proposed by Melo (1990) were adopted for determining the post punching reinforcement. Yield line theory was used for checking the contribution of flexural reinforcement in helping the floor after punching failure in some connections occurred. It was observed for the first example that, according the codes EUROCODE 2:2002 and NBR 6118:2003, P3 connection would not support the increased load and bending moments that would follow a punching failure at P2 connection, and that could lead to a progressive collapse. At the second example was observed that P3 and P15 connections would not support the increased load and bending moments that would follow punching failure at P2 and P14 connections, and that could also lead to a progressive collapse. The third structure was not susceptible to a progressive collapse following a punching failure. The yield line analyses showed that the three structures would have a resistance reserve that would help them in not allowing progressive collapses.
Barbosa, Wallison Carlos de Sousa. "Punção em lajes lisas de concreto armado com pilares de canto reentrante." reponame:Repositório Institucional da UnB, 2012. http://repositorio.unb.br/handle/10482/10968.
Full textSubmitted by Elna Araújo (elna@bce.unb.br) on 2012-07-16T20:10:02Z No. of bitstreams: 1 2012_WallisonCarlosdeSousaBarbosa.pdf: 25662123 bytes, checksum: 781196651e53a3725244b2e1cf6dfd48 (MD5)
Approved for entry into archive by Jaqueline Ferreira de Souza(jaquefs.braz@gmail.com) on 2012-07-18T12:01:09Z (GMT) No. of bitstreams: 1 2012_WallisonCarlosdeSousaBarbosa.pdf: 25662123 bytes, checksum: 781196651e53a3725244b2e1cf6dfd48 (MD5)
Made available in DSpace on 2012-07-18T12:01:09Z (GMT). No. of bitstreams: 1 2012_WallisonCarlosdeSousaBarbosa.pdf: 25662123 bytes, checksum: 781196651e53a3725244b2e1cf6dfd48 (MD5)
A ligação direta entre pilares e lajes de concreto armado é uma alternativa cada vez mais freqüente nos projetos de construção civil. Diversos fatores podem indicar a conveniência da utilização de um modelo estrutural do tipo laje lisa, ou solução com pilar apoiado em uma laje. Em ambos os casos, têm-se a situação da carga aplicada em uma área reduzida, gerando tensões de cisalhamento significativas na região da laje ao redor do pilar ou área carregada. Assim a laje tende a romper por punção. Neste trabalho foram investigados o comportamento estrutural e a resistência última à punção de ligações entre lajes lisas e pilares de canto reentrante. As principais variáveis consideradas foram: armadura de cisalhamento e excentricidade de carga na ligação. Foram ensaiados quatro modelos locais de ligação laje-pilar de canto reentrante, distribuídos em dois grupos: um com duas lajes sem armadura de cisalhamento, ensaiadas com diferentes excentricidades de carga e o outro grupo com duas lajes, uma com três e a outra com quatro camadas de double headed studs com disposição radial. Foram analisados os resultados de cargas últimas, fissuração, deslocamento vertical, deformações das armaduras de flexão e de cisalhamento e do concreto, e rotação das lajes. A armadura de cisalhamento e as diferentes excentricidades de carga influenciaram o comportamento e a carga de ruptura das lajes. Essas influências foram quantificadas. Os resultados experimentais foram comparados com os estimados segundo as normas: NBR 6118:2007, Eurocode 2:2004 e ACI 318:2008. Para os modelos sem armadura de cisalhamento as estimativas de resistência à punção obtidas com a NBR 6118:2007 e o Eurocode 2:2004 foram semelhantes aos resultados obtidos experimentalmente, enquanto que o ACI 318:2008 apresentou resultados mais conservadores de resistência à punção em relação aos observados em laboratório. _________________________________________________________________________________ ABSTRACT
The direct link between reinforced concrete columns and slabs is an alternative increasingly common in civil construction projects. Several factors may indicate the convenience of the use of a structural model of the type flat slab or with column supported by a slab. In both cases, there is the situation of load applied in a small area, generating significant shear stresses in the region of the slab around the column or the loaded area, thus the slab tends to fail by punching. In this work it was investigated the structural behavior and ultimate punching strength of connections between flat slabs and reentrant corner columns. The main variables considered were shear reinforcement and eccentricity of the load on the link. Four local models of slab-reentrant corner column link were tested, divided in two groups: one with two slabs without shear reinforcement tested with different load eccentricities and the other with two slabs, one with three and the other with four layers of double headed studs with radial layout. It was analyzed the results of ultimate load, cracking, vertical displacement, strains in bending and shear reinforcement and at the bottom surface of the concrete, and slab rotation. The shear reinforcement and different load eccentricities influenced the behavior and rupture load of the slabs. These influences were quantified. The experimental results were compared with those estimated according to the codes: NBR 6118:2007, Eurocode 2:2004 and ACI 318: 2008. For models without shear reinforcement, estimates of punching strength obtained with NBR 6118:2007 and Eurocode 2:2004 were similar to those obtained experimentally, while ACI 318:2008 presented more conservative results of punching strength than those observed in laboratory.
Albuquerque, Elaine Jaricuna Pereira de. "Punção em lajes lisas com armadura de cisalhamento e pilar de canto reentrante." reponame:Repositório Institucional da UnB, 2015. http://repositorio.unb.br/handle/10482/18905.
Full textSubmitted by Guimaraes Jacqueline (jacqueline.guimaraes@bce.unb.br) on 2015-12-11T13:17:16Z No. of bitstreams: 1 2015_ElaineJaricunaPereiraDeAlbuquerque.pdf: 12819530 bytes, checksum: 61aacdb45e10b892c4badb6d8da2a742 (MD5)
Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2015-12-11T13:18:06Z (GMT) No. of bitstreams: 1 2015_ElaineJaricunaPereiraDeAlbuquerque.pdf: 12819530 bytes, checksum: 61aacdb45e10b892c4badb6d8da2a742 (MD5)
Made available in DSpace on 2015-12-11T13:18:06Z (GMT). No. of bitstreams: 1 2015_ElaineJaricunaPereiraDeAlbuquerque.pdf: 12819530 bytes, checksum: 61aacdb45e10b892c4badb6d8da2a742 (MD5)
Ligações laje-pilar em lajes lisas podem romper por punção para uma carga inferior à correspondente de flexão, devido às altas tensões advindas do momento fletor e do esforço cortante, e por isso tem sido muito estudadas. No entanto, dentre os tipos de ligação lajepilar (pilar interno, de borda ou de canto), as ligações com pilares de canto reentrante não havia ainda sido estudado com profundidade, principalmente no caso de momentos desbalanceados em uma ou duas direções. Nesta pesquisa foram analisadas experimentalmente 12 (doze) ligações lajes lisas / pilar, com pilar quadrado de canto reentrante com 300 mm de lado, com espessura de 180 mm, e as principais variáveis investigadas foram a presença de armadura de cisalhamento disposta radialmente, a taxa de armadura de flexão na região do pilar, que variou de 0,8 a 2,1%, a presença de armadura de torção no bordo, e o desbalanceamento dos momentos nas duas direções, com excentricidades variando de 267 a 504mm. Durante os ensaios foram monitoradas as deformações nas armaduras de flexão, cisalhamento e torção; deformações no concreto; deslocamentos verticais; padrão de fissuração; cargas últimas; rotações das lajes e modos de ruptura. Os resultados experimentais foram comparados com uma proposição para a determinação das resistências esperadas pelas normas NBR 6118 (2014), Eurocode 2 (2004) e ACI 318 (2014), e pelas recomendações do MC2010 (2013), pois as lajes lisas com pilares reentrantes não são abordados por estas normas e recomendações. Também foi realizada uma simulação numérica utilizando o software ATENA, que emprega o método dos elementos finitos para efetuar análises tridimensionais não lineares em estruturas de concreto armado. ____________________________________________________________________________________________________ ABSTRACT
In failure slab-column connection failure of flat slabs is observed high stresses are originated by that of bending and shearing efforts, which can cause failure by punching with a load lower than the bending. The types of slab-column connection, internal, edge, corner and re-entrant corner can appear in any deck. However the connection slab-column of reentrant corner is not discussed by any research as the other cases, its mechanical model and its behavior with unbalanced moments in one or both directions are unknown. In this research were analyzed experimentally 12 flat slabs with thickness of 180 mm, supported by a square column with sides of 300 mm and molded with machined concrete with average strength of 45 MPa. The experimental results were: strain in bending, shear and torsion reinforcement; concrete strains; vertical displacement; map of cracking; ultimate loads; rotations of the slabs and failure modes. The variables were: eccentricity, bending reinforcement ratio, amount of shear reinforcement and torsion reinforcement. Strength of punching shear get in the tests was compared with the strength provided by the NBR 6118 code (2014), Eurocode 2 (2004), ACI 318 (2014) and MC2010 (2013), but all the standards had to be adapted because they do not cover punching in slabs with reentrant corner column. Also a numerical simulation was made using the ATENA software designed to make non-linear three-dimensional analysis of reinforced concrete structures. Thus, the data monitored in the laboratory ware correlated with the results from finite element modeling. Some of the major contributions of this study were to show the general behavior of the slab connection with reentrant corner column with respect to displacements, strains, cracking, failure mode and failure surface; analyze the behavior and the adapted codes; and show how to treat this type of connection.
Oliveira, Marcos Honorato de. "Punção em lajes lisas com pilar de borda protendidas com cordoalhas não aderentes." reponame:Repositório Institucional da UnB, 2008. http://repositorio.unb.br/handle/10482/5189.
Full textSubmitted by Jaqueline Ferreira de Souza (jaquefs.braz@gmail.com) on 2009-09-23T20:19:57Z No. of bitstreams: 1 2008_MarcosHonoratoOliveira.pdf: 4642102 bytes, checksum: a12b2d8203feedcdc8b7c4fbf80c530e (MD5)
Approved for entry into archive by Gomes Neide(nagomes2005@gmail.com) on 2010-07-05T20:47:40Z (GMT) No. of bitstreams: 1 2008_MarcosHonoratoOliveira.pdf: 4642102 bytes, checksum: a12b2d8203feedcdc8b7c4fbf80c530e (MD5)
Made available in DSpace on 2010-07-05T20:47:40Z (GMT). No. of bitstreams: 1 2008_MarcosHonoratoOliveira.pdf: 4642102 bytes, checksum: a12b2d8203feedcdc8b7c4fbf80c530e (MD5) Previous issue date: 2008-08
Serão apresentados neste trabalho resultados experimentais dos ensaios de oito modelos locais de ligação laje/pilar de borda. Este trabalho faz parte da primeira série de ensaios da tese de doutorado de Helder Pontes Gomes na Universidade de Brasília, no ano de 2008. Buscou-se por meio desses ensaios avaliar a influência da relação do momento fletor dividido pela força cortante (M/V), da relação c/d, da presença de overhang em alguns dos modelos e do nível de protensão na resistência à punção para o cálculo da ligação laje/pilar de borda de lajes protendidas. Foram realizadas também comparações entre os resultados experimentais e as previsões analíticas estabelecidas pela NBR 6118:2003 e por algumas normas internacionais de referência, como o ACI 318M-02 e o EUROCODE 2:2001, para então verificar se as formulações preconizadas pelas normas acima são convenientes. Algumas das análises realizadas indicaram que o acréscimo de tensão nos cabos está diretamente associado ao tipo de carregamento aplicado. As deformações sofridas pelo concreto tiveram influência da disposição dos cabos de protensão. A presença de overhang aumenta a rigidez da ligação, influencia no padrão de fissuração e na forma do cone de ruptura. As comparações com as normas mostraram que a NBR 6118:2003 (média: 3,11 e desvio padrão: 0,38) apresentou um menor desempenho em relação a todas as outras normas avaliadas. O ACI 318M-02 (média: 2,56 e desvio padrão: 0,26), embora menos que a NBR 6118:2003, também se apresentou bastante conservador por ter em sua formulação limitações para resistência característica do concreto e eficácia da protensão em pilares de borda com distância à borda inferior a 4.d. Sem a consideração das restrições para resistência característica e eficácia da protensão em pilares de borda, foi analisado assim chamado ACI* 318M-02, que apresentou os melhores resultados para todos os modelos ensaiados com média igual a 1,29 e desvio padrão igual a 0,14. Como esse não se trata de norma em vigor o melhor desempenho para as normas foi do EUROCODE 2:2001, com média igual a 1,84 e desvio padrão igual a 0,24. Todas as normas analisadas mostraram-se não estarem ajustadas para relação c/d maior que 2,0 e para a contribuição do overhang na carga de ruptura. __________________________________________________________________________________ ABSTRACT
Were presented in this work results and analysis of eight local models of slabs-edge columns connections with post tensioned unbounded tendons tested in University of Brasilia. Those tests are simultaneously part of the first series of experimental tests for the doctorate thesis of Helder Pontes Gomes. The intent of this work was evaluate the influence of the bending moment/shear force (M/V), c/d relation, the level of post tension and the presence of overhang in some of specimens in the pushing shear resistance of post tensioned flat slab-edge columns connections. Were made comparisons of those results with analytical predictions established by NBR 6118:2003 and some others relevant international codes, being them: ACI 318M-02 and EUROCODE 2:2001, and made considerations about the efficiency of the formulations of each of them. The analysis of the tension of the tendons shows that increase of the tensions during the test is directly related with the applied load. The deformation of the inferior surface of the concrete around the connection was influenced by the arrangement of the tendons and by the presence of the overhang. The presence of the overhang enhances the connection rigidity and influence the standard of cracking and the shape of the truncated cone of failure. The carried out analysis of the codes showed that the NBR 6118:2003 (average: 3,11 and standard deviation: 0,38) as the more conservative code among those studied. The ACI 318M-02 code (average: 2,56 and standard deviation: 0,26), although less than the NBR 6118:2003, was fairly conservative because of the restrictions to concrete strength and effectiveness of the post tension in slab-edge columns connections. Without these restrictions, the called ACI* 318M-02 become the code with better performance for all specimens, with 1,29 of average and 0,14 of standard deviation. But as this code is not available, the code that had better performance for connections tested was EUROCODE 2:2001, with 1,84 of average and 0,24 of standard deviation. All codes analyzed showed not be adjusted to range of c/d larger than 2,0 and to the contribution of the overhang in the evaluation of the failure load.
Nappi, Sergio Castello Branco. "Analise comparativa entre lajes maciças, com vigotes pre-moldados e nervuradas." reponame:Repositório Institucional da UFSC, 1993. http://repositorio.ufsc.br/xmlui/handle/123456789/75976.
Full textMade available in DSpace on 2012-10-16T06:13:57Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-08T18:13:05Z : No. of bitstreams: 1 94191.pdf: 3734169 bytes, checksum: 9072caf465c7c8d7f1d81e5f2fafda26 (MD5)
Mesmo com a contínua construção de edificações, ainda persistem algumas dúvidas no que se refere a estrutura de concreto, particularmente a execução das lajes. Neste trabalho, se faz uma análise das lajes com vigotes pré-moldados, maciça, nervurada com blocos de poliestireno expandido, nervurada com blocos de concreto celular autoclavado e nervurada com blocos cerâmicos, a partir de três modelos de projeto arquitetônico de edificações unifamiliares, com dois pavimentos. Nesta estrutura, de concreto revestido, utiliza-se formas e cimbramento de madeira. Após um embasamento teórico, efetua-se o cálculo estrutural, não somente para as lajes mas também para as sua vigas de sustentação. Posteriormente, realiza-se uma comparação entre estes elementos, verificando-se a composição das cargas nas vigas, a relação entre o peso próprio das lajes e a carga total da estrutura e o consumo dos principais materiais utilizados. Finalmente, mostra-se a composição dos custos para cada tipo de laje estudado, com base nos preços dos materiais e da mão-de-obra praticados na região da grande Florianópolis.
Oliveira, Paulo Alexandre da Cruz. "Pré-esforço em lajes de edifícios." Master's thesis, Escola Superior de Tecnologia do Barreiro, 2012. http://hdl.handle.net/10400.26/4332.
Full textThe pre-stress, as a growing technology and viewing its potential application in buildings, provides one of the most important implementations in the field of structural engineering and construction. A search for practical solutions would show that the pre-stress solutions are often not adopted because some of the actors of the project are not familiarized with the technology and its advantages. Based on this lack of knowledge, we decided to research about this topic, focusing specifically on the application of this technology in concrete slabs in buildings.
Borowski, Gustavo da Costa. "CÁLCULO DE DESLOCAMENTOS EM LAJES NERVURADAS." Universidade Federal de Santa Maria, 2005. http://repositorio.ufsm.br/handle/1/7751.
Full textEste trabalho tem como objetivo principal contribuir para o desenvolvimento de uma metodologia capaz de determinar através de simulações numéricas os deslocamentos verticais em lajes nervuradas, submetidas a carregamentos uniformemente distribuídos. Foi analisada uma laje nervurada unidirecional e outra bidirecional, aplicando-se o método do material homogêneo equivalente para a determinação do comportamento da seção transversal da nervura. Os materiais foram caracterizados a partir das recomendações da NBR 6118 e também pelos ensaios realizados pelos autores das lajes de referência, que servirão para a validação deste trabalho. Com o emprego de elementos finitos de barra e isoparamétricos com vinte nós, simulou-se a estrutura da laje nervurada unidirecional, obtendo como principal resultado, a flecha no centro do vão. Constatou-se que o modelo com elementos finitos cúbicos de vinte nós representou de forma satisfatória o comportamento da estrutura. Para os elementos finitos de barra, foram obtidas curvas com comportamento semelhantes a estrutura real, mas com valores de deslocamentos bem abaixo dos valores experimentais. Numa análise minunciosa, foi verificado que o elemento finito utilizado não considerava todas as características da seção Te. Então, identificou-se um fator de correção, resultante do quociente entre a largura da mesa e a largura da nervura, para ser aplicado aos valores obtidos, gerando um diagrama carga-deslocamento corrigido. Estes últimos resultados obtidos apresentaram valores compatíveis a estrutura real. Para a análise da laje nervurada bidirecional foi feita a opção pela utilização de ensaio realizado em modelo reduzido, aplicando o método com elementos finitos de barra, através de uma grelha. Na determinação do material homogêneo equivalente foram agrupadas as nervuras em faixas, de acordo com a similaridade da forma e da armadura, gerando um comportamento mecânico para cada faixa. Os resultados obtidos também foram corrigidos pelo fator de correção, aproximando-se dos valores experimentais, salvo nos bordos da laje em que a influência dos momentos fletores negativos é maior. Assim, contribuiu-se para o desenvolvimento de uma metodologia capaz de calcular as flechas nas lajes nervuradas.
FONTES, Luiz José Gonçalves. "Verificação ao cisalhamento em lajes nervuradas." Universidade Federal de Pernambuco, 2017. https://repositorio.ufpe.br/handle/123456789/25625.
Full textApproved for entry into archive by Alice Araujo (alice.caraujo@ufpe.br) on 2018-08-16T19:51:23Z (GMT) No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Luiz José Gonçalves Fontes.pdf: 2051860 bytes, checksum: 44156147dd32512a7f10a1590206c9e2 (MD5)
Made available in DSpace on 2018-08-16T19:51:23Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Luiz José Gonçalves Fontes.pdf: 2051860 bytes, checksum: 44156147dd32512a7f10a1590206c9e2 (MD5) Previous issue date: 2017-02-23
O uso de lajes nervuradas tem sido uma prática constante nas obras de construção civil. Esse tipo de laje, constituída de nervuras (em uma ou mais direções) ligadas entre si por uma mesa, proporciona uma economia maior de concreto em relação a uma laje maciça, uma vez que é eliminado o concreto que fica, normalmente, na região tracionada entre as nervuras. Um dos inconvenientes desse tipo de laje, devido ao formato das nervuras (geralmente com seções trapezoidais para facilitar a desforma) e a presença das armaduras de flexão, é a montagem dos estribos, quando há necessidade de armadura para combater o cisalhamento, principalmente no Brasil, onde não são comercialmente fabricadas armaduras padronizadas que se adequem ao formato das nervuras. Sendo assim, a dispensa da armadura de cisalhamento, quando possível, deve ser adotada de forma a melhorar o processo de montagem do sistema. No presente trabalho são apresentadas as prescrições da normas Canadense, Americana e Brasileira, que usam parâmetros distintos para as verificações do cisalhamento em nervuras e elementos de seções em formato trapezoidais, e apresentados resultados de ensaios descritos na literatura de nervuras contínuas de concreto armado, com e sem armadura de cisalhamento. Em seguida esses resultados são comparados com os calculados segundo as normas citadas e apresentadas conclusões e recomendações para verificação, detalhamento e dispensa de armadura de cisalhamento em nervuras sendo sugerido a adoção de um coeficiente de minoração para a equação da Norma Brasileira que limita a resistência máxima ao cortante para dispensa de armadura de cisalhamento nesses elementos.
The use of joist slabs has been a constant practice in civil construction. This type of slab consists of ribs connected to each other by a table, provides a greater saving of concrete in relation to a solid slab, since the concrete that is usually in the region is eliminated Between the ribs. One of the drawbacks of this type of slab, due to the shape of the ribs (generally tapered webs to facilitate the withdrawal of forms) and the presence of flexural reinforcement, is the placement of the stirrups when there is a need for reinforcement to resist shearing, mainly in Brazil, where they are not commercially manufactured standardized stell that conforms to the shape of the ribs. Thus, the dispensing of the shear reinforcement, when possible, must be adopted in order to improve the system assembly process. The present work presents the prescriptions of the canadian, cmerican and brazilian standards, which use different parameters for shear checks on ribs and trapezoidal shape elements, and present results of tests already performed on continuous ribs of reinforced concrete, with and without shear reinforcement. Then, these results are compared with those calculated according to the norms cited and presented conclusions and recommendations for verification, detailing and dispensing of shear reinforcement in ribs and suggested to adopt a reduction coefficient for the Brazilian Standard equation that limits the maximum strength to shear for dispensing shear reinforcement in these elements.
LOPES, André Felipe de Oliveira. "Estudo comparativo entre lajes nervuradas moldadas no local com fôrmas de polipropileno e lajes pré-fabricadas treliçadas." Universidade Federal de Pernambuco, 2015. https://repositorio.ufpe.br/handle/123456789/16648.
Full textMade available in DSpace on 2016-04-18T12:05:12Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) DISSERTAÇÃO_ANDRÉ LOPES.pdf: 5318919 bytes, checksum: 7fcd711cb764df5b1129609d50537bdd (MD5) Previous issue date: 2015-05-29
FACEPE
Diante do desenvolvimento da construção civil nos últimos anos e do aumento da concorrência entre as empresas deste setor, faz-se necessário oferecer alternativas estruturais e construtivas que permitam maior eficiência e redução de custos nas execuções das obras. O desenvolvimento das tecnologias na área de informática vem propiciando cada vez mais condições para análises estruturais de alta complexidade, que estão materializadas em programas comerciais de cálculo estrutural, os quais tornam o dimensionamento das estruturas mais produtivo e estão cada vez mais importantes na rotina do engenheiro estrutural. Este trabalho apresenta um estudo técnico comparativo entre lajes nervuradas em concreto armado bidirecionais moldadas no local com fôrmas de polipropileno e unidirecionais pré-fabricadas treliçadas. Inicialmente, realizou-se um estudo paramétrico comparativo de esforços, deslocamentos e de custo de lajes com geometrias quadradas e retangulares em função de suas dimensões em planta. Em seguida, desenvolveu-se uma análise comparativa de um estudo de caso, onde se adotou um edifício modelo localizado na cidade de Caruaru-PE, o qual foi dimensionado empregando os dois sistemas construtivos de lajes abordados nesta pesquisa. Na análise do referido estudo de caso observou-se o comparativo de esforços, deslocamentos verticais e horizontais e estabilidade da estrutura, bem como, os custos dos elementos estruturais que compõem a estrutura do edifício analisado para os dois modelos de sistemas construtivos utilizados. As simulações das estruturas foram efetuadas utilizando modelos gerados em computador no software CYPECAD versão 2012a. Os cálculos dos esforços e deslocamentos, assim como o dimensionamento da estrutura, foram obtidos através do referido programa. Após o dimensionamento e a análise dos resultados, foram extraídos do programa os quantitativos referentes aos esforços cortantes, momentos fletores, deslocamentos, consumos de fôrmas, concreto e armadura. Em seguida, fez-se a composição do custo total da estrutura para cada sistema estrutural e efetuou-se a comparação entre os dois sistemas construtivos de lajes analisados neste trabalho.
With the development of civil construction in recent years and the increased competition between the companies in this sector, is made necessary provide structural and constructive alternatives that allowing greater efficiency and cost savings in the execution of works. The development of the technologies in computer science area comes increasingly providing conditions for structural analysis of high complexity, which are materialized in commercial programs of structural calculation, which make the sizing of more productive structures and are increasingly important in the structural engineer's routine. This work presents a comparative technical study between ribbed slabs bidirectional molded on site with polypropylene molds and lattice slabs unidirectional prefabricated in reinforced concrete. Initially was held a comparative parametric study of efforts, displacements and cost of slabs with square and rectangular geometries according to their dimensions in plant. Then developed a comparative analysis of a case study, which adopted a model building located in the city of Caruaru-PE, which has been sized using the two building systems of slabs covered in this research. In analysis of this study of case was observed the comparative of efforts, vertical and horizontal displacements and stability of the structure, as well as the costs of structural elements comprising the building structure analyzed for the two types of construction systems used. The simulations of the structures were made using computer generated models in CYPECAD software version 2012a. The calculations of the efforts and displacements, as well as the sizing of the structure, were obtained through this program. After the sizing and analysis of the results, were extracted from the program the quantitatives relating to shear efforts, bending moments, displacements, molds consumption, concrete and armor. Then, was made the composition of the total cost of the structure for each structural system and was executed the comparison between the two building systems of slabs examined in this work.
Dantas, Silvia Tondella. "Desempenho de embalagens metalicas para bebidas carbonatadas : avaliação de latas fabricadas por soldagem eletrica frente as latas convencionais." [s.n.], 1987. http://repositorio.unicamp.br/jspui/handle/REPOSIP/255379.
Full textDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos
Made available in DSpace on 2018-07-14T19:10:10Z (GMT). No. of bitstreams: 1 Dantas_SilviaTondella_M.pdf: 23016877 bytes, checksum: 1f8bba3fc4ceaa278da37d6dca23793d (MD5) Previous issue date: 1987
Resumo: Avaliou-se o desempenho de quatro tipos de latas, sendo duas produzidas por tecnologias de soldagem elétrica Soudronic e Conoweld e duas pelo processo convencional (solda Sn/Pb), Com exceção da lata produzida pelo processo Conoweld, que foi fabricada em folha cromada, o material de embalagem foi a folha-de-flandres. Todas as latas eram envernizadas internamente. O produto estudado foi refrigerante de limão. A vida-de-prateleira do produto nas diversas embalagens foi determinada em teste de estocagem óelo período de seis meses em duas condições de temperatura, 23ºC e 35ºC. Os principais parâmetros considerados foram a avaliação visual interna das embalagens, a concentração de ferro e a avaliação organoléptica do produto. Verificou-se que, embora apresentem pequenas diferenças entre si, todos os tipos de latas de folha-de-flandres (soldadas pelo processo convencional e eletricamente) apresentaram um bom desempenho pelos seis meses de estocagem, enquanto a lata em folha cromada soldada eletricamente sofreu um processo de corrosão acentuado, e o produto nela acondicionado atingiu concentrações de ferro acima do admissível (2ppm aos seis meses de estocagem) entre 90 e 120 dias no armazenamento a 23ºC e entre 75 e 90 dias no armazenamento a 35ºC. Para a estocagem a 23ºC esse foi o tempo estabelecido para a vida-de-prateleira do produto nessa embalagem enquanto para a estocagem a 35ºC a vida-de-prateleira estabelecida foi entre 62 e 75 dias devido ao sabor metálico percebido na avaliação sensorial. A avaliação sensorial do refrigerante de limão permitiu verificar a ocorrência de deterioração do sabor do produto durante a estocagem, nas duas condições de temperatura, ocorri da no produto acondicionado nos diversas tipos de embalagem metálica e também na garrafa de vidro utilizada como referencia. Em função disso, o fator limitante da vida-de-prateleira do refrigerante de limão nas embalagens em folha-de-flandres foi a alteração organoléptica, sendo o produto considerado inaceitável aos 150 dias de estocagem a 23ºC e 105 dias de estocagem a 35ºc. A caracterização das embalagens quanto à porosidade do verniz e proteção da região de soldagem mostrou-se diretamente relacionada as diferenças no desempenho encontradas entre as embalagens. A avaliação de amostras da região de soldagem no tempo zero e aos 180 dias de estocagem a 23ºC por meio de microscopia eletrônica e difração de raiosX possibilitou a visualização e confirmação da formação de pontos de corrosão e existência de defeitos no sistema de envernizamento das embalagens.
Abstract: The performance of four kinds of cans, two of them produced by Soudronic and Conoweld welding technologies, and the other two by the conventional process (soldered), was evaluated. With the exception of the can produced by the Conoweld process that was manufactured from tin free steel, the packaging material was tinplate. All of the cans were lacquered internally. The product studied was a lemon soft drink. The shelf-life of the product in the several packagings was determined by storage test within a period of six months at two temperature conditions, 23ºC and 35ºC. The main parameters considered were the internal visual evaluation of the packaging, the concentration of iron and the sensorial evaluation of the product. It was verified that although the tinplate cans presented some small differences among them selves, all of the types of tinplate cans (welded and soldered) presented a good performance during the six months of storage, while the welded tin free steel can suffered a process of accentuated corrosion and the product packaged in it reached concentrations of iron above the permissible tolerance (2ppm at six months of storage) between 90 and 120 days in storage at 23ºC and between 75 and 90 days in storage at 35ºC. For the storage at 23°C, that was the period established for the shelf-life of the product in this packaging, while for the storage at 35°C the shelf-life was between 62 and 75 days in function of the metallic flavor detected in the sensorial evaluation. The sensorial evaluation of the lemon soft drink allowed us to detect the product flavor deterioration during the storage at the two temperature conditions that occured in the product packaged in several types of metalic packaging and also in glass used as reference. In function of that, the limitating factor of the shelf--life of the lemon soft drink in tinplate packagings was the sensorial alteration. The product was considered unacceptable at 150 days of storage at 23ºC and at 105 days of storage at 35ºC. The caracterization of the packagings as to lacquer porosity and protection of the region of welding proved to be directly related to the differences in performance verified among the packagings. The evaluation of samples of the region of welding at time zero and at 180 days of storage at 23°C in Scanning Electron Microscope and X-Ray Diffraction enabled the visualization and confirmation of points of corrosion formation and the existence of defects in the system of packaging lacquering.
Mestrado
Mestre em Ciência de Alimentos
Bremer, Cynara Fiedler. "Vigas mistas em perfis formados a frio com lajes mistas e lajes moldadas sobre painéis de concreto celular." Universidade Federal de Minas Gerais, 2007. http://hdl.handle.net/1843/PASA-7GFHJL.
Full textEste trabalho consiste na avaliação do desempenho estrutural de dois sistemas de vigas mistas de aço e de concreto, ambos com vigas de aço em perfis formados a frio (PFF).No primeiro sistema a laje é constituída por uma camada de concreto moldado sobre painéis de concreto celular autoclavado (CCA) e os conectores de cisalhamento são de perfil U simples, também formado a frio. O segundo sistema é constituído de laje mista com fôrma de aço incorporada; para os conectores de cisalhamento são utilizados parafusos de cabeça sextavada e rebites tubulares com rosca interna. Foram realizadas avaliações por meio de ensaios de deslizamento (push out) para a determinação do comportamento e da resistência dos conectores e também ensaios de modelos de vigas em escala natural, sob condições de serviço e em estado limite último. Foram realizadas análises com tratamentos estatísticos e de regressão apropriados, que permitiram a proposição de critérios de dimensionamento específicos para as vigas mistas de aço e concreto com PFF, a partir da calibração de previsões teóricas com base nas prescrições das normas brasileiras pertinentes, entre elas a ABNT NBR 8800 (1986) e seu projeto de revisão, de setembro de 2006. Os resultados obtidos demonstram que as vigas mistas com PFF desenvolvidas no presente estudo podem ser utilizadas em sistemas de pisos de edificações residenciais, por apresentar desempenho estrutural satisfatório, especialmente os edifícios de baixo custo com até 7 pavimentos desenvolvidos em recentes pesquisas na Universidade Federal de Minas Gerais, cujos sistemas construtivos foram adotados por algumas companhias de habitação do Brasil, tais como a COHAB-MG e a CDHU-SP.
Watts, Robert Blyth. "The emplacement of crystal-rich intermediate lavas." Thesis, University of Bristol, 2002. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.393085.
Full textAlmeida, Audrey Gregori Melchert de. "Contribuição ao estudo das lajes mistas protendidas." [s.n.], 1998. http://repositorio.unicamp.br/jspui/handle/REPOSIP/258043.
Full textDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil
Made available in DSpace on 2018-07-24T13:57:21Z (GMT). No. of bitstreams: 1 Almeida_AudreyGregoriMelchertde_M.pdf: 2945704 bytes, checksum: 307b35c63c16d7b0aee456c48a30ad5b (MD5) Previous issue date: 1998
Resumo: Apresenta-se neste trabalho um procedimento de verificação do dimensionamento de lajes mistas protendidas, compostas por vi gotas pré-moldadas com seção transversal em forma de PI invertido, protendidas pelo sistema de pré-tração e complementadas na obra com o lançamento de concreto local. Foram previstos na fase de construção três casos de escoramento com 0,1 ou 2 estais. Assim, desenvolveu-se uma rotina para a verificação automatizada destas lajes. Apresenta-se também o método das fibras de fluência utilizado na determinação das perdas de protensão, o problema da retração diferencial e o cálculo das perdas progressivas, importantes para este tipo de estrutura
Abstract: This dissertation presents a procedure to verify the calculation of composite prestressed concrete slabs. This is formed by precast beams with inverted PI cross section, prestressed by the pretensioning system and finished in the construction site with local concrete. Were foreseen three supportable cases in the construction stage with O, 1 or 2 supports. Therefore, it was developed a program to automatized verification of these slabs. Were also considerate in the determination of the losses of prestress the fibers of creep method, the problem of differential shrinkage and progressives losses, very importants for this kind of structure
Mestrado
Estruturas
Mestre em Engenharia Civil
Tivelli, Erick. "Absorção de impacto por latas de alumínio." [s.n.], 2012. http://repositorio.unicamp.br/jspui/handle/REPOSIP/263138.
Full textDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica
Made available in DSpace on 2018-08-20T08:11:17Z (GMT). No. of bitstreams: 1 Tivelli_Erick_M.pdf: 5369905 bytes, checksum: b9254f481c50f8e409adfc4b024d1c79 (MD5) Previous issue date: 2012
Resumo: O presente trabalho analisou experimentalmente a utilização de latas de alumínio como absorvedor de energia de impacto. Foram realizados ensaios de compressão estáticos e dinâmicos objetivando correlacionar as deformações das latas com a energia absorvida. Foram analisadas a influência de fatores como, preenchimento da lata (ar ou vermiculita expandida) e disposição do arranjo para receber o impacto nas condições de latas separadas ou agrupadas. O levantamento das características da deformação que estão vinculadas com a absorção do impacto permitem especificar o tipo ideal da estrutura a ser impactada para diferentes aplicações. Os resultados do estudo viabilizaram a utilização das latas de alumínio, na condição de absorvedores de energia com deformação controlada, em barreiras de trenó de impacto
Abstract: The present study examined experimentally the use of aluminum beverage cans as absorbing impact energy elements. Crushing tests were performed aiming to correlate static and dynamic deformations of the cans with the energy absorbed. The study evaluated several conditions for forming a barrier capable of absorbing impact energy during impact tests on the sled. Static and dynamic crushing tests were performed aiming a better understanding of the behavior of the cans in such situations, and also analyzed the influence of factors such as filling the can (air or expanded vermiculite) and arrangement of the impact barrier, this tested the can as a honeycomb and in separate conditions. The study of the characteristics of deformation that are linked to allow the absorption of impact specify the ideal type of structure to be impacted for different applications. The results obtained in this work enabled the use of aluminum cans as agents of energy absorbers for the sled test
Mestrado
Materiais e Processos de Fabricação
Mestre em Engenharia Mecânica
Ichpas, Adauto Heber, Gutiérrez Diego Regalado, Vanegas Lina Cuéllar, and Andrés Sandro Sánchez. "Planeamiento estratégico para la Provincia de Lamas." Master's thesis, Pontificia Universidad Católica del Perú, 2017. http://tesis.pucp.edu.pe/repositorio/handle/123456789/9635.
Full textThe present study aims to develop a strategic plan for the province of Lamas with a vision board for 2030, which presents the strategies and objectives needed to increase its level of competitiveness, giving value to the human resource, and taking the education, health and main economic activities reformulation as pillars of development for increase the ability to generate benefits through taking action on the entire productive chain. The implementation of the proposed strategies looking for the development of the province in order to become a reference in production, manufacturing and export of fine aroma cocoa and community rural tourism. These strategies were formulated considering the competencies and responsibilities of the provincial government. The results show that despite the external and internal environment adversity, the province of Lamas has sufficient potential to be one of the most competitive provinces of Peru, through the change from the comparative advantages to competitive advantages
Tesis
Araujo, Carlos Antonio Menegazzo. "Contribuições para projeto de lajes alveolares protendidas." Florianópolis, SC, 2011. http://repositorio.ufsc.br/xmlui/handle/123456789/94752.
Full textMade available in DSpace on 2012-10-25T15:32:56Z (GMT). No. of bitstreams: 1 294408.pdf: 7039416 bytes, checksum: 63623dfb34e69bc5ef37d5e8a834529c (MD5)
O enfoque desta tese de doutorado é a contribuição teórica para o projeto estrutural de lajes alveolares protendidas com relação aos efeitos dependentes do tempo e a região do apoio. O modelo reológico utilizado nesse trabalho, fundamentado no método do coeficiente característico de envelhecimento, permitiu a análise de barras considerando o comportamento dependente do tempo do concreto e do aço por meio das funções de relaxação. Com isso, foi possível analisar os efeitos construtivos e o comportamento em diferentes etapas da vida útil das lajes alveolares isostáticas que são unidas para formar uma estrutura contínua com seção transversal composta. As análises dos resultados mostraram que a utilização de lajes alveolares com continuidade longitudinal é uma solução eficiente, mas requer verificações adicionais de projeto devido ao processo construtivo. O programa computacional PROTENLAJE, que permite a análise, dimensionamento e verificação de peças pré-tracionadas isostáticas e hiperestáticas nos estados limites de serviço e últimos, foi desenvolvido e utilizado neste estudo. Como contribuição para o estudo da região dos apoios, apresenta-se, por um lado, resultados de modelos numéricas não lineares, considerando a aderência entre a armadura e o concreto, e por outro lado, uma metodologia analítica para verificação da resistência à força cortante, baseada na Modified Compression Field Theory (MCFT) e nos conceitos de segurança do Eurocode 2. Os modelos numéricos representaram bem o comportamento de ensaios experimentais e clarificaram a distribuição de tensões na região de apoio. Os resultados obtidos com a metodologia analítica proposta para a verificação da resistência à força cortante alcançou os melhores resultados quando comparada com as normas CSA A23.3 e o Eurocode 2, utilizando um banco de dados com 129 ensaios experimentais de lajes alveolares. Além disto, a metodologia proposta é adequada para aplicações de projeto, visto sua simplicidade.
Castro, Vanessa Andreina Berto de. "Análise comparativa de custos de lajes fungiformes." Master's thesis, Universidade de Aveiro, 2011. http://hdl.handle.net/10773/7223.
Full textNa construção civil são cada vez mais procuradas soluções que sejam simultaneamente simples e eficazes e que proporcionem redução de custos, rapidez e flexibilidade de execução. Por este motivo as lajes fungiformes têm sido uma das melhores alternativas para a construção de pavimentos em edificações. Com a presente dissertação pretende-se analisar e comparar os custos entre dois tipos de lajes fungiformes mais correntemente utilizadas, aligeiradas com moldes recuperáveis e maciças com capitéis. Na análise em causa a utilização considerada para os pavimentos foi do tipo residencial e foram abrangidos os vãos mais correntes em lajes fungiformes. Para a análise das lajes recorreu-se a dois métodos diferentes, o método dos elementos finitos e os métodos simplificados, com o intuito de comparar os resultados de cada método. Para o dimensionamento, verificações de segurança e disposições construtivas, considerou-se a regulamentação em vigor aplicável nos estados membros do Comité Europeu de Normalização, nomeadamente os Eurocódigos. De modo a facilitar a tomada de decisão entre a utilização destes dois tipos de soluções, na análise de resultados é feita uma comparação das deformadas e dos esforços obtidos e são apresentados os custos dos recursos necessários e o custo total de cada laje para cada modelo de estudo. A partir deste trabalho chegou-se à conclusão que as lajes aligeiradas tem um custo inferior que as lajes maciças para vãos superiores a 8 m. Foi também possível concluir que para análise de lajes fungiformes, o método dos elementos finitos é um método mais abrangente que o método simplificado.
The construction industry is increasingly looking for solutions that are both simple and effective and that provide cost savings, speed and flexibility of execution. For this reason the flat slabs have been one of the best alternatives for the slab construction in building. With the present dissertation we aim to analyze and compare costs between two types of flat slabs more commonly used, waffle grid flats with recovered molds and solid ones with enlarged column heads. In this analysis the use considered for the floors was of the residential type of slabs and were included the most common spans in flat slabs. For the analysis of the slabs we turned to two different methods, the finite element method and the simplified methods in order to compare the results of each method. For the design, security checks and construction rules, it was considered the current legislation applied in the member countries of the European Committee for Standardization, namely the Eurocodes. In order to make the decision between the use of these two types of floors easier, in the analysis of the results it is made a comparison between the deflection and the internal forces obtained and is shown the price for the necessary resources and the total cost of each slab for each study model. From this work on, we came to the conclusion that waffle slabs have a lower cost than solid slabs for spans over 8 m. It was also possible to conclude that for the analyzes of flat slabs, the finite elements method is more extensive than the simplified one.
Inácio, Roberto Alves. "Análise numérica do punçoamento em lajes fungiformes." Master's thesis, Faculdade de Ciências e Tecnologia, 2010. http://hdl.handle.net/10362/5289.
Full textFernando, Jerónimo Catiavala Gertrudes. "Lajes fungiformes pré-esforçadas concepção e dimensionamento." Master's thesis, Faculdade de Ciências e Tecnologia, 2013. http://hdl.handle.net/10362/8730.
Full textO pré-esforço é uma deformação imposta a uma estrutura que introduz um estado de tensão que em geral contraria os efeitos associados às acções permanentes. Pretende-se com este trabalho, analisar e dimensionar uma laje fungiforme pré-esforçada, tendo em conta duas soluções (maciça e maciça com bandas). Fez-se uma introdução em relação os tipos de lajes pré-esforçadas, cofragens perdidas e reutilizáveis. Para o estado limite de serviço, foram analisadas na laje as vibrações, deformações e a fendilhação, limitando os valores obtidos com os valores regulamentares. Em relação aos estados limites últimos verificou-se a segurança à flexão, onde foram determinadas as armaduras ordinárias. O efeito do pré-esforço na resistência ao punçoamento foi analisado nos dois exemplos. Ao longo do trabalho verificou-se também que, a solução da laje maciça com bandas, permite uma utilização de pré-esforço, cerca de 60% do necessário da solução sem bandas. Finalizando o trabalho com a viabilidade técnica e económica.
Gouveia, Nuno Dinarte. "Punçoamento em lajes de betão com fibras." Master's thesis, Faculdade de Ciências e Tecnologia, 2012. http://hdl.handle.net/10362/8432.
Full textUma solução que apresenta grande potencial para a melhoria da capacidade de carga ao punçoamento, é aquela promovida pela introdução de fibras de aço descontínuas, orientadas aleatoriamente ao betão utilizado na ligação laje-pilar. Por causa da sua orientação aleatória, este tipo de reforço tem a vantagem de ser eficaz para servir de ponte de ligação das fissuras que se formam em várias direcções. Esta solução é potencialmente mais rentável e menos "intrusiva" em comparação com outras, evitando os custos de amarração e colocação das armaduras transversais, como ocorre no reforço com armadura específica de punçoamento. Neste trabalho, são apresentados os resultados de uma investigação experimental sobre o comportamento ao punçoamento de modelos de lajes fungiformes, realizados com um betão de resistência à compressão em torno dos 35 MPa. Construíram-se seis modelos de laje com betões reforçados com fibras de aço (BRFA) usando diferentes percentagens volumétricas de fibras (0.00, 0.50%, 0.75%, 1.00% e 1.25%). A previsão da capacidade de carga de cada modelo foi feita recorrendo a modelos de cálculo propostos por alguns autores, incluindo o do novo Model Code 2010 [15], nos quais foram introduzidas as características mecânicas dos betões usados, resultantes de ensaios em vigas entalhadas e painéis de laje quadrados, realizados no âmbito de outro trabalho desenvolvido por Fernandes [16]. Os resultados mostram que, de uma forma geral, as previsões são satisfatórias. A deformação dos modelos, a extensão da armadura longitudinal, a capacidade de carga e modo de rotura são analisados. Os resultados mostraram não só um aumento na capacidade de carga, mas também da capacidade de deformação, quando comparada com a laje de referência, onde não foi utilizado BRFA.
Santine, Carlos Roberto. "Projeto e construção de lajes pré-moldades de concreto armado." Universidade Federal de São Carlos, 2005. https://repositorio.ufscar.br/handle/ufscar/4712.
Full textThis work presents the main recommendations for the design of precast slabs strips, comprising precast lattices and infill elements, strengthened by cast-in-situ concrete overlay. Based on Brazilian codes of practice for precast slabs, this work describes characteristics of materials, discusses the main design requirements and analytical models as well as verifications at the serviceability limit state. This work emphasises a methodology that considers the nonlinear behaviour the reinforced concrete, describing the proposed formulations to determine the moment of inertia based on a cracked section, using software that allows for the incremental loading technique. Using this method a better approximation for the real performance of the reinforced concrete structure is obtained. Finally, this work proposes a new type for precast slabs strips, without the lattice truss reinforcement, which may become an innovative technology for the precast sector in Brazil.
Este trabalho mostra as principais recomendações para a utilização das lajes nervuradas, compostas por nervuras pré-fabricadas, elementos inertes de enchimento e concreto lançado na própria obra. À luz das normas brasileiras correlatas, descreve as características dos materiais empregados neste sistema, aborda os principais critérios e modelos empregados em seu dimensionamento e verificações dos estados limites de serviço. Face às não-linearidades físicas do concreto, dá ênfase à metodologia empregada para se efetuar a análise não-linear, descrevendo as formulações propostas para a obtenção da inércia no estádio II, quando as peças já se encontram fissuradas, descrevendo ainda, a utilização da técnica do carregamento incremental, conseguida através do emprego de um sistema computacional existente no mercado, mostrando que, desta forma, os resultados obtidos para o comportamento estrutural dessas lajes são mais próximos da realidade. E, finalizando, propõe um novo tipo de concepção para estas lajes que poderá se constituir em uma inovação tecnológica para o setor.
Chayña, Santa Cruz Karol Katherine. "Evaluación y análisis de las relaciones ecológicas, sociales y culturales de los árboles y palmeras con la población de la ciudad de Lamas – San Martín." Master's thesis, Pontificia Universidad Católica del Perú, 2020. http://hdl.handle.net/20.500.12404/16911.
Full textTrabajo de investigación
Nicácio, Wanderley Gustavo. "Reforço à punção em lajes lisas de concreto armado com polímeros reforçados com fibra de carbono." reponame:Repositório Institucional da UnB, 2013. http://repositorio.unb.br/handle/10482/15390.
Full textSubmitted by Alaíde Gonçalves dos Santos (alaide@unb.br) on 2014-03-27T11:18:55Z No. of bitstreams: 1 2013_WanderleyGustavoNicacio.pdf: 10752397 bytes, checksum: ce82c2ce66dbcae541cfa5ded50a6bb0 (MD5)
Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2014-03-27T15:56:41Z (GMT) No. of bitstreams: 1 2013_WanderleyGustavoNicacio.pdf: 10752397 bytes, checksum: ce82c2ce66dbcae541cfa5ded50a6bb0 (MD5)
Made available in DSpace on 2014-03-27T15:56:41Z (GMT). No. of bitstreams: 1 2013_WanderleyGustavoNicacio.pdf: 10752397 bytes, checksum: ce82c2ce66dbcae541cfa5ded50a6bb0 (MD5)
Esta pesquisa avalia experimentalmente o comportamento da ligação laje-pilar, num sistema de lajes lisas de concreto armado, localizadas internamente à edificação e submetidas a carregamento simétrico, reforçadas ao cisalhamento com polímeros de fibra de carbono (PRFC). O método de reforço consiste em se aplicar a manta de PRFC como elemento resistente ao cisalhamento, por meio de sua colagem através de furos perpendiculares ao plano da laje. Neste estudo experimental, foram realizados oito modelos de lajes lisas com dimensões de 2500 x 2500 mm de comprimento, altura nominal de 180 mm, pilares quadrados centrados com dimensão de 300 mm e mesma taxa da armadura, variando-se: a técnica de reforço, distribuição dos furos, número e área de reforço por camada. A manta de PRFC foi aplicada com a adaptação da técnica Dowel, similar a armaduras do tipo pino, e por meio da técnica Stitch que se assemelha a estribos fechados. Os resultados dos ensaios foram analisados quanto a deslocamentos verticais, deformação específica no concreto, no aço e na armadura de cisalhamento, carga, fissuração, superfície e modo de ruptura. Como as normas atuais não tratam do reforço ao cisalhamento com armaduras de cisalhamento do tipo PRFC, foi avaliada a aplicação de prescrições estabelecidas pelo ACI 318 (2011), Eurocode 2 (2004) e ABNT NBR 6118 (2007), associadas com as limitações do ACI 440.2R (2008) que trata da aplicação dos materiais de PRF. ______________________________________________________________________________________ ABSTRACT
This research experimentally evaluates the behavior of slab-column connections in a reinforced concrete flat slab system, internally located in the building and subjected to symmetrical loading, strengthened to the shear with carbon fiber reinforced polymer (CFRP). The strengthening method consists in applying CFRP sheet as shear resistant element, by bonding it through perpendicular holes to the plane of the slab. This experimental study consisted of tests on eight flat slab models with the following dimensions 2500 x 2500 mm length, trickness of 180 mm, supported on centered square cross section columns of 300 mm side and same flexural reinforcement ratio, using the following variations: the strengthening technique, the pattern of holes and the number of peripheral lines of the shear reinforcement. The CFRP sheet was applied with an adaptation of the Dowel technique, was used, which is similar to shear studs, and the stitch technique, which resembles closed stirrups. The test results were examined by verifying the vertical displacements, the concrete, steel and shear reinforcement strains, ultimate loads, cracking patterns, surface and failure modes. As the current standards do not deal with strengthening to shear with CFRP reinforcement, it was assessed the application of the code’s required from by ACI 318 (2011), by Eurocode 2 (2004) and by ABNT NBR 6118 (2007), associated to the limitations of ACI 440.2R (2008) which provides guidance for the selection, design, and installation of FRP systems for concrete structures.