Dissertations / Theses on the topic 'Lente de contacto'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the top 50 dissertations / theses for your research on the topic 'Lente de contacto.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.
Salvador, Susete Maria Arraiano. "Adaptação de lente de contacto tórica, olho seco severo, endotropia parcialmente acomodativa." Master's thesis, Universidade da Beira Interior, 2013. http://hdl.handle.net/10400.6/1657.
Full textThe curricular internship, accomplished at the Ocular Eye Care clinic, allowed the initial contact with the labor market, through a connection between the educational system and the business market. During the internship, we had the necessary material to develop skills in Optometry, which provided clinical training in pediatric optometry, geriatric optometry, binocular vision, contact lenses, low vision and eye health. Throughout the same period, several clinical cases occured, with various degrees of complexity. This report contains three of those cases, as well as the solution to each case and their analysis and discussion.
Pérez-Prados, Roque. "Caracterización de los factores clave para la adaptación de lentes de contacto hidrofílicas multifocales." Doctoral thesis, Universidad de Alicante, 2017. http://hdl.handle.net/10045/72616.
Full textPauné, i. Fabré Jaume. "Diseño, estudio y validación de una lente de contacto de gradiente de potencia para controlar la miopía = Design, study and validation of a radial refractive gradient contact lens for myopia control." Doctoral thesis, Universitat Politècnica de Catalunya, 2015. http://hdl.handle.net/10803/327035.
Full textLa miopía es el principal problema de visión en el mundo, con riesgos asociados cuanto mayor es su magnitud. Por ello, resultan de gran importancia las intervenciones que puedan limitar o prevenir la progresión de la miopía, disminuyendo los riesgos de patologías oculares y potencial ceguera. Las investigaciones en primates han mostrado que el proceso de crecimiento ocular es dependiente de la imagen, actúa localmente en el ojo y que la fóvea no es esencial. En concreto, la periferia, de modo aislado, puede mediar el desarrollo normal de la refracción y cuando hay un conflicto entre las señales visuales de la fóvea y la periferia, estas últimas dominan sobre las centrales en el desarrollo ocular. Estudios recientes, con lentes de ortoqueratología y multifocales, han mostrado que su óptica, que incluye el movimiento de adelantamiento de la imagen periférica, reduce el crecimiento del ojo. En este sentido, el principal objetivo fue determinar si un lente de contacto diseñado para producir desenfoque periférico miope podía ralentizar el avance de la miopía. Esta tesis, que describe 6 estudios principales, es el resultado de los esfuerzos para diseñar, patentar, validar la óptica de la lente experimental y realizar dos ensayos longitudinales. El primer capítulo incluye la descripción del proceso para diseñar y patentar la lente. Esta, de diseño innovador, dispone una zona óptica, única, progresiva y continua, con una adición prefijada en 1,5 D a 30º respecto al eje. Diseñada utilizando el modelo de ojo de Atchison, obtuvo una patente Española de triple "A" con el número: ES 2406381B1. Se condujo un estudio piloto inicial con diez sujetos para constatar su validez óptica y evaluar en materiales hidrofílicos y permeables a los gases (GP) los cambios refractivos periféricos inducidos, al igual que los ópticos. En función de los resultados, se condujeron dos estudios con 52 y 59 sujetos para medir los cambios en refracción periférica, aberraciones ópticas, sensibilidad al contraste (CS), agudeza visual y Lag acomodativo. El material GP resultó en un cambio miópico de la imagen periférica más allá de los 10 grados de excentricidad nasal y temporal del campo visual, suficientes para adelantar la imágen en la mayor parte de los miopes evaluados. Con lente blanda, la refracción relativa periférica mostró cambios significativos desde 30º nasal a 15º temporal y a 30º grados en el equivalente esférico. También hubo un aumento significativo de las aberraciones de alto orden, así como una disminución de la sensibilidad al contraste y del Lag acomodativo. Elementos contribuyentes a frenar la miopía. Los estudios longitudinales investigaron el efecto de control de la lente experimental. El grupo de lente GP sufrió una gran pérdida de seguimiento y sólo un caso fue finalmente analizado. Sin embargo, gracias al diseño del estudio intrasujeto cruzado, se pudo valorar que el ojo que llevaba la lente experimental, en cada uno de los dos periodos de que constaba el estudio, aumentó menos la miopía que en el contralateral. Sugiriendo un potencial a ser evaluado en un estudio longitudinal futuro. Adicionalmente, las lentes experimentales blandas, tras 2 años de estudio longitudinal frenaron un 43% y un 27% el incremento refractivo y axial respectivamente, en comparación con un grupo de gafas monofocales. Además, el grupo experimental no mostró diferencias respecto un grupo control de ortoqueratología. Este es el primer ensayo clínico controlado que proporciona información sobre la progresión de la miopía 12 meses antes de entrar en el estudio, se compara la eficacia de dos tratamientos con diferentes lentes de contacto y presenta una visión completa de las causas potenciales de control de la miopía mediante el análisis de la refracción periférica. Las lentes experimentales evidencian un efecto de control de la miopía prometedor. Otros potenciales diseños basados en el conocimiento proporcionado en este trabajo podrían incrementar su efectividad.
Brás, Ana Cláudia da Silva. "Defeitos epiteliais corneais espontâneos crónicos em cães : estudo retrospetivo de 42 casos." Master's thesis, Universidade de Lisboa, Faculdade de Medicina Veterinária, 2017. http://hdl.handle.net/10400.5/14070.
Full textObjetivo: Realizar um estudo retrospetivo sobre defeitos epiteliais corneais espontâneos crónicos (SCCEDs) em cães. Métodos: Foram incluídos no estudo pacientes com SCCED e sem história de doença corneal diagnosticados no HVR (2014-2017). Foi analisada a raça, sexo, olho afetado, duração dos sinais clínicos, tratamento com recurso a ponta de diamante (DBD), com ou sem colocação adicional de lente de contacto e a existência de doença endócrina ou cutânea concomitante e o uso prévio de corticosteróides ou imunomoduladores. Resultados: Um total de 42 olhos preenchia os critérios de inclusão. Correspondiam a 23 fêmeas e 19 machos de 16 raças de cães diferentes, sendo a mais comum Bulldog Francês (23,8%), seguido de cães sem raça definida (19,0%) e Boxer (16,8%). A idade média foi de 9,0 ± 3,36 anos, variando entre 2-17 anos. Dos 42 casos, 4 eram bilaterais e 38 unilaterais. A duração média dos sinais clínicos foi de 4,0 ± 7,6 semanas, variando entre 1-44 semanas. Dos 42 casos, 32 foram tratados apenas com DBD e 10 com a colocação adicional de uma lente de contacto. Em 10 casos os animais tinham dermatite atópica, em 3 hipotiroidismo e em 2 diabetes mellitus. Dos 10 casos em que o animal tinha dermatite atópica, 3 tinham sido previamente tratados com corticosteróides ou imunomoduladores. Não se verificou uma diferença significativa nos tempos de resolução dos SCCED com e sem lente de contacto adicional (Kaplan-Meier; p=0,581). Conclusões: A raça mais representada foi o Bulldog Francês, e não o Boxer, o que se pode dever à sua popularidade crescente no nosso país. A técnica de DBD foi eficaz para solucionar o problema. Neste estudo não foi encontrado um menor tempo de resolução da úlcera de córnea nos animais em que se recorreu ao uso adicional de uma lente de contacto.
ABSTRACT - SPONTANEOUS CHRONIC CORNEAL EPITHELIAL DEFECTS IN DOGS: A RETROSPECTIVE STUDY OF 42 CASES - Purpose: A retrospective study of dogs with spontaneous chronic corneal epithelial defects (SCCEDs) was performed. Methods: Patients with a diagnosis of SCCED with no history of concurrent corneal disease from HVR (2014-2017) were eligible for inclusion. Animal breed, age, sex, affected eye, duration of clinical signs, treatment with diamond burr debridement (DBD) alone or plus contact lens and concomitant endocrine or skin diseases and the previous use of corticosteroids or immunomodulators were analysed. Results: A total of 42 eyes met the inclusion criteria. They corresponded to 23 females and 19 males of 16 different dog breeds, the most common being French Bulldog (23,8%), followed by Mongrel (19,0%) and Boxer (16,8%). The mean age was 9,0 ± 3,36 years old, ranging between 2-17 years old. Of the 42 cases, 4 were bilateral and 38 unilateral. The mean duration of clinical signs was 4,0 ± 7,6 weeks, ranging from 1-44 weeks. Of the 42 cases, 32 were treated with DBD alone and 10 plus a contact lens. In 10 cases the dog had atopic dermatitis, in 3 hypothyroidism and in 2 diabetes mellitus. Of the 10 cases of animals with atopic dermatitis, 3 previously used corticosteroids or immunomodulators. There was not a statistical significant difference between healing times of SCCEDs with or without contact lens (Kaplan-Meier; p=0,581). Conclusions: French Bulldog was the most represented breed instead of Boxer, which might be due to its increased popularity in Portugal. DBD demonstrated to be a good technique for the resolution of this disease. This study found no improvement on healing time with the additional use of a contact lens.
N/A
Silva, Ana Rita Baptista da. "Biofilmes e lentes de contacto." Master's thesis, [s.n.], 2012. http://hdl.handle.net/10284/3762.
Full textO Biofilme pode ser designado como um grupo funcional de microrganismos aderidos a uma superfície estando envolvidos numa matriz exopolimérica. As bactérias organizam-se em Biofilmes, devido a, quando não estão organizadas em microcolónias terem reduzida taxa de sobrevivência. A estrutura e formação destes filmes são heterogéneas, integrando em si nichos de bactérias com graus de crescimento distintos. O estudo da relação dos Biofilmes com as lentes de contacto é pertinente, pois estas são amplamente utilizadas na correção de erros refrativos ligeiros, como na terapêutica de uma série de doenças da superfície ocular. A capacidade dos microrganismos aderirem à superfície das lentes de contacto e formarem Biofilmes desempenha um papel preponderante no desenvolvimento de infeções oculares, relacionadas com o uso destes dispositivos médicos. A formação de Biofilmes não depende só das propriedades da lente mas também dos microrganismos e da sua interação com o material. A prevenção da contaminação em lentes de contacto pode ajudar a reduzir a incidência de doenças oculares, tais como a queratite microbiana. Certas estratégias podem ajudar nesta prevenção, como a modificação dos materiais na produção das lentes. O tratamento, na maioria das infeções oculares bacterianas, é efetuado simultaneamente com antimicrobiano e com anti-inflamatório (corticosteroide). A combinação de antibiótico com corticosteroides promove a proteção contra novas infeções, bem como confere atividade anti-inflamatória, diminuindo a resposta imunitária do organismo. Nesta revisão bibliográfica vai-se abordar o modo como o Biofilme se forma e se estrutura e como interfere com as lentes de contato, bem como a história, os tipos de lentes, materiais e far-se-á uma abordagem à anatomia e fisiologia do olho. As infeções provocadas pelos Biofilmes serão mencionadas e referenciar-se-ão as bactérias mais vulgares, bem como os seus meios preventivos e as terapêuticas adequadas a cada infeção. A biofilm is a functional group of microorganisms that are attached to a surface and are involved in a exopolymeric matrix. Bacteria organize themselves into biofilms since single-cells have a reduced survival rate than microcolonies. The structure and formation of these films are heterogeneous, being integrated by niche of bacteria with different degrees of growth. The study of the involvement of biofilms with contact lenses is relevant, since there are widely used in the mild correction of optical refractive errors and in the treatment of several ocular surface diseases. The ability of microorganisms to adhere to the surface of contact lenses and form biofilms plays a major role in the development of ocular infections related to the use of these medical devices. The biofilm formation is not only dependent of the properties of the lens but also of the microorganisms and their interaction with the material. The prevention of contact lens contamination may help reduce the incidence of ocular diseases, such as microbial keratitis. Certain strategies can help prevent this, such as modifying the materials used in the production of lenses. Most bacterial eye infections are treated with the simultaneous use of antibiotic and anti-inflammatory (corticosteroid) drugs. This combination promotes a protection against new infections, as well as confer anti-inflammatory activity, decreasing the body’s immune response. This literature review will address the way in which the biofilm is formed and structured and how it can interact with contact lenses. The history and the type of lenses and materials used will also be addressed, as well as an analysis of the anatomy and physiology of the human eye. Infections caused by biofilm will be mentioned, reporting the most common bacteria, as well as the therapeutic and preventive means for each infection.
Marqués, Calvo Ma Soledad (María Soledad). "Colonización fungica de lentes de contacto." Doctoral thesis, Universitat Politècnica de Catalunya, 1998. http://hdl.handle.net/10803/6754.
Full textPara ello se ha diseñado una fase experimental en la que se han observado, mediante microscopía óptica, las lentes procedentes de usuarios a fin de determinar la presencia o ausencia de hongos. Cuando se detectaron, y para poder proceder a su identificación taxonómica, se procedió a la realización de cultivos.
Las lentes nuevas fueron cultivadas con diferentes cepas de hongos y se valoró la frecuencia y densidad de colonización según las condiciones de cultivo establecidas.
La caracterización morfológica de las diferentes especies fúngicas, experimentadas y encontradas, se realizó utilizando microscopía óptica, confocal y electrónica de barrido.
Los resultados obtenidos indican que: el 11,82% de las lentes procedentes de usuarios mostraban contaminación. Entre los hongos contaminantes encontrados se describen tres nuevas citas, Gliomastix, Humicola y Phoma. Así mismo, se ha establecido que únicamente las cepas 93150 de Candida albicans y 2700 de Aspergillus niger fueron cepas de colonizar las lentes nuevas.
Por otra parte, se ha comprobado que la composición de los medios de cultivo, su evaporación y las características quimicas de las lentes (ionicidad e hidrofilia), son factores que influyen en la frecuencia de colonización y en la densidad de las hifas invasoras.
Finalmente, la microscopía confocal por reflexión de luz ha permitido visualizar las colonias internas y su grado de penetración en el material de la lente.
Las conclusiones obtenidas representan una contribución al conocimiento de los fenómenos determinantes del desarrollo de hongos en los diferentes polímeros estudiados. Suponen, además, un avance en el campo de la contactología clínica y explican algunos de los problemas.
Castejón, Mochón José Francisco. "Estudio de las aberraciones oculares y su corrección mediante lentes de contacto hidrofílicas en ojos normales y muy aberrados." Doctoral thesis, Universidad de Murcia, 2006. http://hdl.handle.net/10803/10840.
Full textThe ocular wave aberration is strongly related with the visual quality having specific values for each eye. Its measurement and correction is challenging for fundamental research as well as for clinical practice. In this work we develop an experimental apparatus to measure the ocular wavefront based on a Shack-Hartmann sensor with a high dynamic range. We use it for measuring monochromatic ocular aberration in two subject groups: a) normal young subjects (normal group hereafter) and b) penetrating queratoplasty eyes (pathologic group hereafter). The results show that mean RMS values of the high order aberrations in the pathologic group was ten times higher than that of the normal group. Further, there is a strong correlation between the corneal aberrations (obtained by corneal topography) and ocular aberrations in the pathological group. We study the aberration correction using soft contact lenses, custom designed from each subject aberrations, by mean of both experiments and theoretical predictions. The study is carried out for three types of eyes: normal, keratoconus and penetrating queratoplasty. Results show that the main factors limiting this correction method are owing to both the mean position and rotation of the contact lenses on eye. We found that the normal subjects show a loss of optical quality relative to standard correction (sphere and cylinder), caused by expected displacements of the lenses contacts. In spite of the rotations and translations expected of contact lenses, there are, however, pathologic cases in which it is possible to reduce the RMS and increase visual quality, such as it was experimentally demonstrated in the keratoconus eyes.
Bellini, Luciano Porto. "Estudo comparativo entre o telescópio com lente de contato e o telescópio convencional em pacientes com baixa visão." reponame:Biblioteca Digital de Teses e Dissertações da UFRGS, 2009. http://hdl.handle.net/10183/17787.
Full textPurpose: To compare the conventional telescope (CT) with the contact lens telescope (CLT) in patients with age-related macular degeneration (AMD) and low-vision, with respect to visual acuity (VA), visual field (VF), patient satisfaction with the vision provided by the telescope (VS), telescope use difficulties (UD) and patient satisfaction with the cosmetic appearance of the telescope (CS). Methods: In a masked randomized clinical trial, 12 patients with AMD and low-vision were enrolled in 2 groups with 6 patients each: group 1 (CLT use) and group 2. (CT use) The telescopes used in this study were standardized to have the same magnification power. (2.8x) Visual field and VA were obtained before and during the telescope use, while VS, UD and CS were obtained after the telescope use. Results: There were no significant differences between groups at baseline. Both groups achieved VA improvement with telescopes compared to baseline (P=0.002 in CLT group and P<0.001 in CT group) and there were no significant differences between groups in this regard. Visual field was reduced by 15° in CLT group (P<0.001) and by 54.3° in CT group (P<0.001) compared to baseline, and VF differences between groups were also significant during telescope use. (P<0.001) Scores observed in both groups were similar in regard to VS. Telescope use difficulties were significant higher in CLT group (P=0.003) as well as CS scores (P<0.001) compared to CT group. Conclusions: Both telescopes provide similar improvement in VA in AMD patients with low-vision, but CLT caused less VF reduction than CT use. Patient satisfaction with the cosmetic appearance of the telescope was higher in CLT group, but UD was also higher in this group compared to CT group.
Rodríguez, Vallejo Manuel. "Diseño, caracterización y aplicaciones clínicas de lentes de contacto multifocales aperiódicas." Doctoral thesis, Universitat Politècnica de València, 2017. http://hdl.handle.net/10251/76166.
Full textLa miopía es el error refractivo de mayor prevalencia a partir de los 20 años de edad e impide la visión nítida a distancia lejana. La presbicia, por otra parte, es una anomalía de la función visual que aparece a partir de los 45 años, que impide la visión nítida a distancia próxima, y que afecta a toda la población por ser un defecto natural asociado a la edad. Las lentes de contacto multifocales representan una solución para facilitar que los pacientes présbitas puedan ver de forma simultánea a múltiples distancias. Además, podrían ser utilizadas, según recientes teorías sobre las señales ópticas que modulan el crecimiento ocular, para ralentizar la progresión de la miopía en niños en etapas de desarrollo. En esta Tesis se proponen dos nuevos diseños de lentes de contacto aperiódicas para ralentizar el desarrollo miópico o compensar la presbicia. El primero de ellos posee como principal ventaja inducir un mayor error relativo periférico con una menor afectación de la visión central en comparativa con la primera lente comercializada con el fin de ralentizar la progresión de la miopía. Este diseño ha sido fabricado, caracterizado y medida su eficiencia real en una muestra de sujetos miopes demostrando un buen acuerdo con su base teórica. El segundo de los diseños, enfocado a la compensación de la presbicia, también ha sido fabricado, caracterizado y adaptado en una serie de sujetos présbitas con el fin de evaluar el rendimiento visual alcanzado con los prototipos. No obstante, para cumplir esta tarea era necesario disponer de una amplia batería de test visuales para medir el rendimiento visual a múltiples distancias. Es por ello que otro de los objetivos dentro de esta Tesis fue analizar la capacidad de los iPad para ser utilizados como sistemas de reproducción de aplicaciones para la medida del rendimiento visual. Se han desarrollado y validado nuevas aplicaciones de medida de agudeza visual, sensibilidad al contraste y estereopsis. Con las nuevas aplicaciones disponibles, se midió el rendimiento visual en los sujetos présbitas adaptados con la lente aperiódica, mejorando significativamente el rendimiento visual a distancia próxima y mostrando como ventaja principal la baja pupilo-dependencia y buena tolerancia al descentramiento pese a tratarse de un diseño zonal.
La miopia és l'error refractiu amb major prevalença a partir dels 20 anys d'edat i impedeix la visió nítida a distància llunyana. La presbícia, d'altra banda, és una anomalia de la funció visual que apareix a partir dels 45 anys, que impedeix la visió nítida a distancia pròxima, i que afecta a tota la població per ser un defecte natural associat a l'edat. Les lents de contacte multifocals representen una solució per facilitar que els pacients prèsbites puguen veure de forma simultània a múltiples distancies. A més, podrien ser utilitzades, segons recents teories sobre les senyals òptiques que modulen el creixement ocular, per a ralentitzar la progressió de la miopia en xiquets en etapes de desenvolupament. En aquesta Tesis es proposen dos nous dissenys de lents de contacte aperiòdiques per a ralentitzar el desenvolupament miòpic o compensar la presbícia. El primer d'ells té com a principal avantatje induir un major error relatiu perifèric amb una menor afectació de la visió central en comparació amb la primera lent comercialitzada amb la finalitat de ralentitzar la progressió de la miopia. Aquest disseny ha sigut fabricat, caracteritzat y s'ha mesurat la seua eficiència real en una mostra de subjectes miops demostrant un bon acord amb la seua base teòrica. El segon dels dissenys enfocat a la compensació de la presbícia, també ha sigut fabricat, caracteritzat y adaptat en una sèrie de subjectes prèsbites amb la finalitat d'avaluar el rendiment visual obtingut amb els prototips. No obstant, per complir aquesta feina era necessari disposar d'una àmplia bateria de test visuals per mesurar el rendiment visual a múltiples distàncies. És per açò que un altre dels objectius dins d'aquesta Tesis fou analitzar la capacitat dels iPad per a ser utilitzats com sistemes de reproducció d'aplicacions per a la mesura del rendiment visual. Han sigut dissenyades y validades noves aplicacions de mesura de l'agudesa visual, sensibilitat al contrast y estereòpsis. Amb les noves aplicacions disponibles, es va medir el rendiment visual en els subjectes prèsbites adaptats amb la lent aperiòdica, millorant significativament el rendiment visual a distancia pròxima i mostrant com avantatje principal la baixa pupilo-dependència i bona tolerància al descentrament a pesar de tractar-se d'un disseny zonal.
Rodríguez Vallejo, M. (2016). Diseño, caracterización y aplicaciones clínicas de lentes de contacto multifocales aperiódicas [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/76166
TESIS
Silva, Liliana Carvalho da. "Efeitos adversos associados ao uso extensivo de lentes de contacto de silicone hidrogel." Master's thesis, Universidade da Beira Interior, 2013. http://hdl.handle.net/10400.6/1497.
Full textAlthough silicone hydrogel contact lenses for extensive wear are the most widely used because of its advantages, that is allowing more oxygen with a minor amount of water and to provide a proper visual correction to waive form and handling over a period considerable time, there are some adverse effects associated with extensive use of contact lenses of this type of material. Due to the situation described above, it is important to have knowledge of the root causes of these events as well as signs and symptoms to avoid and solve the problem in the best way. For this purpose, this bibliographic review will be described adverse effects associated with the extensive wear of silicone hydrogel contact lenses, as well as signs and symptoms, treatments and carried out some experiments.
Sousa, Juliana Nunes. "Tradução e validação do questionário "Contact Lenses Dry Eye Questionnaire" (CLDEQ)." Master's thesis, Universidade da Beira Interior, 2012. http://hdl.handle.net/10400.6/1219.
Full textJorge, Marina Pereira. "Suspeita de glaucoma, insuficiência de convergência e adaptação de lentes de contacto hidrófilas." Master's thesis, Universidade da Beira Interior, 2013. http://hdl.handle.net/10400.6/1666.
Full textThe formulation of this report, entitled ‘Glaucoma Suspicion, Convergence Insufficiency and Toric Soft Contact Lenses Adaptation’, appears as the culmination of the internship phase developed for about six months, at Dr. Ergo- Ótica Aplicada, Lda Clinic, in Viseu. The glaucoma is a pathology characterized by specific alterations in the papilla and field of vision, generally followed by ocular hypertension. If not detected and treated early can compromise ocular health and visual acuity of the patient, in extreme situations can result in blindness. Early detection of glaucoma is crucial to better diagnosis and treatment. However, this does not always happen because the first damage is manifested in the peripheral visual field, which results in defects to the patient. The insufficiency of convergence is an anomaly characterised by the incapacity of obtaining and/or keeping an adequate convergence without effort, that is to say, a person’s incapacity of keeping the adequate binocular alignment in objects that get closer to a near distance (2,3). Regarding the adaptation of Contact Lenses, this becomes more and more important in an Optometrist’s everyday life. Correctly designed and adapted, the contact lenses compensate, and sometimes, reduce in a dynamic way, ammetropias, corneal irregularities and certain binocular dysfunctions, improving the visual capacity (4).In the specific case of Toric Soft Contact Lenses (LCHT), the value 0.75D assumes the maximum level accepted of uncorrected astigmatism.
Aldrigui, Bibiana Rocha. "Desenvolvimento de lentes de contato gelatinosas contendo nanocápsulas produzidas com baixo teor de água." reponame:Biblioteca Digital de Teses e Dissertações da UFRGS, 2016. http://hdl.handle.net/10183/170670.
Full textDinis, Ana Belmira Trindade. "Suspeita de glaucoma, excesso de divergência e adaptação de LC hidrófila tóricas." Master's thesis, Universidade da Beira Interior, 2013. http://hdl.handle.net/10400.6/1491.
Full textDuring the completion of any traineeship there are several clinical cases that a young optometrist may encounter. Thus, the following report analysis three clinical cases, selected during the traineeship made in the clinical Ocular Eye Care. Each case is drawn up according to an anamnesis, as well as, the most varied optometric tests essential to the analysis and diagnosis of the problem of each individual. Suspected glaucoma, insufficiency of divergence and adaptation hydrophilic toric CL are the themes that make up the clinical cases in question.
Correia, Stephanie de Jesus Ventura. "Anomalia na vergência fusional positiva, adaptação de lentes de contacto hidrófilas tóricas, anomalia macular." Master's thesis, Universidade da Beira Interior, 2013. http://hdl.handle.net/10400.6/1661.
Full textThis report is based on the internship that occured in the Ocular Eye Care Clinic, located in Aveiro city. The internship consisted in attending lectures, doing appointments, making and analyzing exams, in order to consolidate knowledge in the correction and treatment of multiple refractive errors, as well as binocular anomalies. The content of this work presents the development of three clinical cases: Macular Anomaly, Anomaly in Positive Fusional Vergence and the Adaptation of Toric Soft Contact Lenses. It is important to diagnose macular diseases such as macular degeneration associated with age at an early stage. If that doesn’t happen it may lead to the irreversible loss of central vision. An anomaly in a positive fusional Vergence is a binocular vision dysfunction that causes specific symptoms, which must not go unnoticed in routine consultations, since they cause instability in the visual system. The adaptation of toric soft contact lenses requires the knowledge of several stabilizing systems, as well as the materials and parameters that compose them, in order to allow the user to reach a stable visual acuity, as well as ocular comfort.
Alves, Sara Gonçalves. "Suspeita de reativação de toxoplasmose, adaptação de lentes de contacto de silicone-hidrogel tóricas, excesso acomodativo." Master's thesis, Universidade da Beira Interior, 2013. http://hdl.handle.net/10400.6/1493.
Full textCremonini, Daniela Nogueira [UNESP]. "Lente de contato biossintética com liberação gradual de ofloxacina para tratamento de ceratite experimental por Staphylococcus aureus em cães." Universidade Estadual Paulista (UNESP), 2008. http://hdl.handle.net/11449/101184.
Full textFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
O contato da córnea com o meio externo torna-a a estrutura ocular mais passível de traumas e lesões, que podem acarretar em formação de intensa cicatriz ou até de perfuração, prejudicando a visão do animal. A utilização de lente de contato terapêutica em medicina veterinária é pouco difundida, devido à dificuldade de adaptação à superfície corneana. Avaliou-se um novo material para tratamento das afecções corneanas a partir de uma membrana de celulose microfibrilar biossintética, utilizada em lesões cutâneas graves. Induziu-se ceratite bacteriana experimental, comparando-se o tratamento com a lente de contato biossintética (LC), impregnada com ofloxacina, à terapia tópica convencional. Realizaram-se avaliações clínicas e morfológicas, além do controle microbiológico e da dosagem de ofloxacina no humor aquoso através do método de cromatografia líquida de alto rendimento (HPLC). Os olhos que receberam a LC desenvolveram reação inflamatória severa, associada à neovascularização profunda, opacidade corneana, secreção, quemose e hiperemia ocular. O exame histopatológico revelou afinamento epitelial com formação de microcistos, edema corneano e infiltrado inflamatório. Estas alterações foram possivelmente causadas pela hipóxia tecidual associada ao inadequado posicionamento da lente. O biomaterial, impregnado com ofloxacina, promoveu liberação gradual, dosada pelo método de HPLC, durante o período de avaliação, entretanto os valores obtidos pela análise foram inferiores aos olhos tratados com colírio, mas suficientes para controlar a infecção por Staphylococcus aureus. Concluiu-se que o material não foi adequado para auxiliar a reparação tecidual corneana, necessitando aprimorar suas características para tal finalidade.
The contact of the cornea with the external way become it to the ocular structure more likely of traumas and injuries, that can cause formation of intense scar or until perforation, harming the vision of the animal. The use of contact lens therapy in veterinary medicine is not very widespread, due to the difficulty of adjusting to the corneal surface. It was intended to study a new material for treatment of the corneal diseases from a cellulose membrane to microfibrillar biosynthetic, used in serious cutaneous injuries. Experimental bacterial keratitis was induced, comparing the treatment with the biosynthetic contact lens (CL) impregnated with ofloxacin, to the Conventional topical therapy. Clinical and morphological evaluations were performed, beyond the microbiologic control and dosage of ofloxacin in the aqueous humor by the high performance liquid chromatography method (HPLC). The eyes that received the CL developed severe inflammatory reaction, associated with neovascularization deep, corneal opacity, secretion, chemosis and ocular hyperemia. The histopathologic examination revealed epithelial thinning with training of microcysts, corneal edema, and inflammatory infiltrate. These alterations are possibly induced due tissue hypoxia associated to the inadequate positioning of the contact lens. The biomaterial, impregnated with ofloxacin, promoted gradual release, measured by HPLC method, during the assessment period, however the values obtained by the analysis were lower in the eyes treated with eye drops, but enough to control the infection by Staphylococcus aureus. It was concluded that the material was not appropriate for help the corneal tissue repair, requiring improvement of their characteristics for this purpose.
Cremonini, Daniela Nogueira. "Lente de contato biossintética com liberação gradual de ofloxacina para tratamento de ceratite experimental por Staphylococcus aureus em cães /." Botucatu : [s.n.], 2008. http://hdl.handle.net/11449/101184.
Full textBanca: Cláudia Valéria Seullner Brandão
Banca: José Luiz Laus
Banca: Antônio Felipe Paulino Figueiredo Wouk
Banca: Antônio Carlos Lotelli Rodrigues
Resumo: O contato da córnea com o meio externo torna-a a estrutura ocular mais passível de traumas e lesões, que podem acarretar em formação de intensa cicatriz ou até de perfuração, prejudicando a visão do animal. A utilização de lente de contato terapêutica em medicina veterinária é pouco difundida, devido à dificuldade de adaptação à superfície corneana. Avaliou-se um novo material para tratamento das afecções corneanas a partir de uma membrana de celulose microfibrilar biossintética, utilizada em lesões cutâneas graves. Induziu-se ceratite bacteriana experimental, comparando-se o tratamento com a lente de contato biossintética (LC), impregnada com ofloxacina, à terapia tópica convencional. Realizaram-se avaliações clínicas e morfológicas, além do controle microbiológico e da dosagem de ofloxacina no humor aquoso através do método de cromatografia líquida de alto rendimento (HPLC). Os olhos que receberam a LC desenvolveram reação inflamatória severa, associada à neovascularização profunda, opacidade corneana, secreção, quemose e hiperemia ocular. O exame histopatológico revelou afinamento epitelial com formação de microcistos, edema corneano e infiltrado inflamatório. Estas alterações foram possivelmente causadas pela hipóxia tecidual associada ao inadequado posicionamento da lente. O biomaterial, impregnado com ofloxacina, promoveu liberação gradual, dosada pelo método de HPLC, durante o período de avaliação, entretanto os valores obtidos pela análise foram inferiores aos olhos tratados com colírio, mas suficientes para controlar a infecção por Staphylococcus aureus. Concluiu-se que o material não foi adequado para auxiliar a reparação tecidual corneana, necessitando aprimorar suas características para tal finalidade.
Abstract: The contact of the cornea with the external way become it to the ocular structure more likely of traumas and injuries, that can cause formation of intense scar or until perforation, harming the vision of the animal. The use of contact lens therapy in veterinary medicine is not very widespread, due to the difficulty of adjusting to the corneal surface. It was intended to study a new material for treatment of the corneal diseases from a cellulose membrane to microfibrillar biosynthetic, used in serious cutaneous injuries. Experimental bacterial keratitis was induced, comparing the treatment with the biosynthetic contact lens (CL) impregnated with ofloxacin, to the Conventional topical therapy. Clinical and morphological evaluations were performed, beyond the microbiologic control and dosage of ofloxacin in the aqueous humor by the high performance liquid chromatography method (HPLC). The eyes that received the CL developed severe inflammatory reaction, associated with neovascularization deep, corneal opacity, secretion, chemosis and ocular hyperemia. The histopathologic examination revealed epithelial thinning with training of microcysts, corneal edema, and inflammatory infiltrate. These alterations are possibly induced due tissue hypoxia associated to the inadequate positioning of the contact lens. The biomaterial, impregnated with ofloxacin, promoted gradual release, measured by HPLC method, during the assessment period, however the values obtained by the analysis were lower in the eyes treated with eye drops, but enough to control the infection by Staphylococcus aureus. It was concluded that the material was not appropriate for help the corneal tissue repair, requiring improvement of their characteristics for this purpose.
Doutor
Noel, Ayma Miguel Ángel, and de la Cruz Gino Antonio Villanueva. "Eficacia de dos soluciones multipropósito frente a biofilms de Pseudomonas aeruginosa inducidos in vitro en lentes de contacto blandos." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2017. https://hdl.handle.net/20.500.12672/5834.
Full textTesis
Andrade, Breno Barth Amaral de. ""Desempenho visual na correção de miopia com óculos e lentes de contato gelatinosas"." Universidade de São Paulo, 2004. http://www.teses.usp.br/teses/disponiveis/5/5149/tde-13102005-165153/.
Full textObjective: to evaluate the visual performance(VP) by Visual acuity(VA)Logmar of high contrast, sensibility of contrast(SC) and wavefront (WF) in myopic patients correct with spectacles and 3 SCL Methods: prospective clinical trial was performed in 40 myopic patients(-1,00 D and -4,50 D). Exams: VA, WF and CS. Results: The WF analysis detected a significant difference in a third order aberration with and without SCL. There was significant difference related to trefoil coefficient in VP between with and without SCL. Conclusion: In VP evaluation with spectacles and SCL the wavefront analysis was more sensible measure of VP when compared with high contrast VA Logmar and CS.
Escandón, García Santiago. "Distorção luminosa em condições escotópicas com sistemas multifocais presbiopia." Master's thesis, Universidade da Beira Interior, 2009. http://hdl.handle.net/10400.6/1970.
Full textPresbyopia is the commonest visual alteration related with age and affects all human beings. The growing prevalence of this disease is due to an ageing population and to future demographic perspectives. This prevalence is shown in the quantity of resources that the ophthalmic industry invests every year in research and development of new technologies to compensate and rehabilitate these patients. Multifocal contact lenses (CL) with simultaneous vision are one of the possible ways to correct presbyopia, although it represents a small part of the adaptations made worldwide. Patients that use these multifocal systems report ghost images and loss of quality of the perceived image due to light distortion phenomena, mainly in low light environments. This subjective information contains valuable data about the quality of vision, thus quantification with objective metrics is required. The central purpose of this work is to evaluate light distortion with multifocal systems utilized to compensate presbyopia and compare the distortion obtained with different commercially available geometries and its binocular combinations. A prospective clinical study with 18 emmetropic volunteers was elaborated at the Clinical and Experimental Optometry Research Lab, University of Minho (Braga, Portugal).Volunteers were randomly assigned to use CL made of the same material either with spherical or two different multifocal designs to quantify Light Distortion Index (LDI) with a Starlights® -Halo v0.91 system (Novosalud, Valencia, Spain) under scotopic lightening conditions; visual acuity was measured with a logarithmic scale, in high contrast (LogMAR100%) and low contrast (LogMAR10%) conditions; anterior surface aberrometric and topographic parameters were measured with and without CL. The results obtained confirm that multifocal CL increase LDI, which varies with each type of multifocal lens, being particularly significant in CL with center-distance geometry (dominant geometry) compared with center-near geometry lenses (nondominant geometry). A binocular summation effect, which reduces LDI when compared to monocular values and is most evident when the manufacturer recommendations are followed (Dominant CL in the dominant eye and Non Dominant in the other eye), was demonstrated. The optical etiology of LDI cannot be explained, in a consistent way, by the aberrations of the anterior ocular surface alone, nor by the topographic parameters of the anterior surface (with or without contact lenses). In conclusion, this work reveals that LDI is a novel technique providing values that allow the quantification of subjective sensations demonstrated by the patients, adding information to the anterior surface aberrometry and can, potentially, relate with the subjective complains reported by users of this kind of optical solutions. This study model can be applied to other developing areas, such as multifocal intra-ocular lenses.
Santos, Denise Leal dos. "Descrição do perfil dos usuários de lentes de contato e ocorrência de casos de ceratite por Acanthamoeba spp. em clínicas particulares e no Hospital de Clínicas de Porto Alegre, RS." reponame:Biblioteca Digital de Teses e Dissertações da UFRGS, 2017. http://hdl.handle.net/10183/170257.
Full textThe growth of the contact lens sector is responsible by the increase Acanthamoeba spp. keratitis cases. The lack of care in cleaning and maintenance of lenses can lead to the occurrence of this disease. In this study, the profile of 196 users of contact lenses from private clinics and Hospital de Clínicas de Porto Alegre (HCPA) was evaluated through interviews, to know the kind of lenses used, cleaning solutions, knowledge of pathology, among others from May 2015 to October 2016. At the HCPA, 112 users (57.1%) answered the questionnaire while in the private clinics 84 users (42.9%) participated of the survey. Most of the interviewees were women 116 (59.2%), white 173 (89.6%) and higher education 91 (46.4%). Soft contact lenses were the most frequent in private clinics (78.6%) while in HCPA the most used lenses were Rigid Permeable Gas (RGP) (60.7%). Most patients wore a multipurpose lens cleaning solution (66.8%), 143 (73.0%) of the interviewees, did not know that an amoeba could be the causer of keratitis. In addition, a survey the occurrence of 25 cases of keratitis caused by Acanthamoeba spp. was investigated (from 1994 to 2015) in a private clinic and at the HCPA. We analyzed data found in medical records, such as those cited above, among others. The majority were women (68.0%), white (44.0%) and higher education (40.0%). Regarding to the use of contact lenses, most patients used gel lenses (66.7%). Regarding to the cleaning and disinfection, 64.0% used multipurpose solution, but they also used saline solution (48.0%) and water (36.0%). Lack of suspicion and the current confusion due to the biomicroscopic findings leads to a misdiagnosis ordinarily confused with herpes simplex (36.0%) we found. Actions that assist the wearers of contact lenses and the continuity of the survey of Acanthamoeba keratitis cases would be necessary for a better knowledge of the pathology and consequent success in the treatment.
Kaddour, Mohsen. "Contribution à la modélisation d'un coupleur actif à onde lente en lignes de transmission à contact métal-semiconducteur." Toulouse, INPT, 1987. http://www.theses.fr/1987INPT034H.
Full textMas, Aixalà Enric. "Caracterització dels paràmetres corneals per a l'adaptació de lents de contacte en casos de queratocon." Doctoral thesis, Universitat Politècnica de Catalunya, 2019. http://hdl.handle.net/10803/667313.
Full textIntroducció: Tant la caracterització de la superfície corneal com la classificació del queratocon en diferents estadis de gravetat es troben en contínua evolució, fruit no només de l’avenç tecnològic, sinó també de la definició de nous paràmetres amb els quals es fan aportacions que ajuden a comprendre millor la geometria, l’estat i l’evolució dels ulls afectats, en comparació amb els ulls sans. És en aquesta evolució del coneixement del queratocon que pren importància l’anàlisi de l’afectació que aquesta patologia produeix en la morfologia corneal perifèrica amb l’objectiu de fer una proposta satisfactòria de disseny de lents de contacte (LC) corneals de gran diàmetre per adaptar a pacients amb queratocon, amb l’objectiu de millorar la seva qualitat de visió amb la màxima comoditat possible i la mínima interferència en al fisiologia ocular. Estudis realitzats: L’objectiu d’aquesta sèrie d’estudis és aportar un millor coneixement de la geometria corneal en tota la seva extensió i, en particular, esbrinar si els canvis corneals produïts en el queratocon són predominantment corneals, limbals/esclerals o una combinació d’ambdós; una informació rellevant a l’hora d’adaptar LC corneals de gran diàmetre en pacients amb diferents estadis d’evolució de la patologia, com a complement o, fins i tot, alternativa a les opcions actuals d’adaptació. Així, s’han analitzat, a través de les imatges de Scheimpflug en diferents meridians oculars, una sèrie de paràmetres corneals i del segment anterior de l’ull a pacients afectats de queratocon en diferents estadis d’evolució. Un dels fets destacables d’aquest estudi suposa l’anàlisi, no només de paràmetres provinents del software propi del Pentacam HR®, sinó de paràmetres mesurats manualment sobre les imatges de Scheimpflug que el propi software no determina, incloent-hi la definició d’un nou paràmetre (distance to the lens, DL, o distància des del punt final de mesurament de la sagita al cristal·lí) que s’ha demostrat prou útil per a la caracterització corneolimbal desitjada. El següent pas ha estat analitzar la perifèria corneal a través del mesurament dels angles corneals perifèrics (corresponents a una longitud de corda d’entre 8,6 i 12,6 mm) i el grau de simetria de revolució perifèrica (diferència entre l’angle corneal perifèric més petit i més gran per a cada ull en particular) amb una metodologia creada sense altre referent anterior, donat que no es tenia constància que les zones estudiades en aquesta investigació haguessin estat mai investigades amb les imatges de Scheimpflug. Finalment, s’ha fet una proposta d’un nou disseny de LC corneal de gran diàmetre per a l’adaptació en casos de queratocon i s’ha desenvolupat un nou mètode de càlcul dels paràmetres d’aquestes lents a partir dels mesuraments fets prèviament sobre les imatges de Scheimpflug. Per tal de fer una comprovació pràctica que pogués aportar uns primers resultats en relació a la viabilitat de l’adaptació d’aquestes LC i del nou mètode de càlcul, s’han realitzat unes primeres experiències clíniques en 20 ulls afectats de queratocon (10 pacients) en diferents estadis d’evolució. Conclusions: El queratocon es troba associat a un increment de la profunditat de la cambra anterior que, al seu torn, implica valors més elevats, tant de la sagita interna (mesurada des de l’endoteli), com de la distància DL. L’increment de la DL seria indicatiu d’un desplaçament cap a la part anterior de l’ull de l’àrea de transició entre còrnia i esclera, amb referència al pla de l’iris. Per tant, els canvis produïts pel queratocon no només afecten la còrnia, sinó tot el segment anterior de l’ull, incloses les estructures límbiques. Existeix un increment significatiu de l’angle corneal perifèric en els estadis inicials del queratocon, el qual no sembla continuar a mesura que avança la patologia. L’angle perifèric mitjà en ulls amb queratocon és, de mitjana, 0,69° més gran que el dels ulls sans. El grau de simetria de revolució perifèrica no presenta diferències entre els grups d’ulls sans i ulls amb queratocon. Per tant, l’adaptació de LC que es recolzen sobre la perifèria corneal i tenen simetria de revolució en aquesta zona serà tan satisfactòria en ulls amb queratocon com ho és en ulls sans. Aquesta conclusió ha estat corroborada amb els resultats obtinguts en l’estudi clínic preliminar, amb uns bons resultats pel que fa a la millora de l’agudesa visual, a la satisfacció de l’usuari, en termes de qualitat visual i comoditat d’ús, i sense alteracions rellevants en la fisiologia ocular detectables en les visites de seguiment.
Santos, Cláudio Miguel Lourenço. "Insuficiência de convergência, adaptação de lentes de contacto hidrófilas tóricas, suspeita de degeneração macular relacionada com a idade." Master's thesis, Universidade da Beira Interior, 2013. http://hdl.handle.net/10400.6/1665.
Full textThis internship report is based on the report of approximately 3 months internship curriculum, that was developed between july and october 2012 in Clinical Ocular Eye Care in Aveiro. This report will serve to complete the last year of master's degree in optometry. During the stage were conducted several surveys and consultations and many cases were observed and analyzed, but only three cases were selected for the report, directed by Dr. Tito Ramos. The internship report is titled by Convergence insufficiency, adaptation of soft toric contact lenses suspected by macular degeneration related to the age, has also a brief introduction to the topics that will be addressed, as well as, analysis of cases with appropriate optometric examination results. At the end it has a conclusion, where I explain some cases and how was the stage in general as both at the level of knowledge as at the level of theoretical knowledge.
Almeida, Ruben Joel Olival. "Suspeita de edema macular cistóide: anomalia na convergência." Master's thesis, Universidade da Beira Interior, 2013. http://hdl.handle.net/10400.6/1498.
Full textIn this internship report are presented three clinical cases that were provided by my internship supervisor and where I did a careful analysis. The first clinical case is about referencing ocular pathology of a patient, where after performing several tests, including retinography and fluorescein angiography, there is a suspicion of a cystoid macular edema. There was the need to send him to an Ophthalmologist to confirm the pathology and to be made other diagnostic complementary exams if necessary, being presented the best therapy for the case. The second is about binocular vision, where after performing various tests and binocularity analysis was diagnosed an anomaly in the convergence in the patient and was proposed a visual therapy and maintenance plan because was the therapy that had better prognosis. The third case is about hydrophilic toric contact lenses, in which a patient was interested in wear contact lenses, being used different tests, including the slit lamp and the topography. After its analysis were adapted contact lenses and it was verified that the lens of the right eye was rotated, having to compensate the respective rotation, restoring the normal VA value.
Rei, Susana Catarina Martins. "Suspeita de degeneração macular: excesso de divergência." Master's thesis, Universidade da Beira Interior, 2013. http://hdl.handle.net/10400.6/1500.
Full textThe content of this work presents the development of three clinical cases of Optometry, analysed during my internship. Suspected macular degeneration, excessive divergence and adaptation of toric soft contact lenses. The macular diseases will lead to decreased central vision, especially near vision; therefore the diagnosis should be made early in order to avoid significant visual loss. Binocular vision is of the most complex and important topic study of Optometry. If it’s not completely compensated, may cause symptoms that affect the normal functioning of vision, excessive divergence is a specific case of binocular vision. Contact lens adaptation should be mastered by Optometrists. The adaptation of toric soft contact lenses is a very rigorous field, because it requires maximum attention in the field of the lens and its properties, as well as the development of stable vision with comfort for the patient. Thus, I present below a study about on each of these subjects, over which I studied during the course of my internship, in order to increase knowledge in distinct areas of Optometry and helping to boost interest in future studies.
Leite, Pedro. "As Forças de Quadrícula: Pontos de contacto entre as Guerras em África e os conflitos actuais." Master's thesis, Academia Militar. Direção de Ensino, 2009. http://hdl.handle.net/10400.26/8492.
Full textPortugal materialized its first participation in Peace Support Operations in 1958. Starting from 1961 and up to 1974, following the insurgency war of the African colony’s people, Portugal got involved in a conflict of a different nature, which forced the political authorities to make major reforms and the military to adopt new doctrines and tactis, appropriate to the characteristics of counter-subversion. Today and after the decolonization, Portugal has conducted its foreign policy in compliance with the agreements made with international organizations and various countries, often detaching military forces in order to participate in Peace Support Operations all over the world. This work intends to analyze how pioneer doctrines, used by the grid forces in the conduct of military operations in the African war from 1961 to 1974, have a pratical and current application in Peace Support Operations. On the first chapter it was tried to understand what the grid forces are, how the concept appeared and how its employment had been directed during the African war in 1961-1974. The second chapter presents an evolutionary perspective of national foreign policies, stating the international agreements that tie the member state to provide armed forces in order to participate in peace-support operations promoted by diverse international organizations in various regions of the world. The third chapter analyzes the use of technical and doctrinal procedures in peace-support operations, through the interviews to participant Officers in the Theater of Operations in Bosnia-Herzegovina, Kosovo, East Timor and Afghanistan, presented in the fourth chapter. This chapter addresses the training and the National doctrinal stands. The fifth chapter presents the contact points between the procedures of the Peace-Support Operations and the procedures of the grid forces during the African war 1961/1974. In a comparative perspective, the interviews are analyzed, in the sixth chapter. In short: by applying a deductive method in the bibliographical review and the implementation and analusis of interviews, it is pretended to demonstrate the timeliness of the procedures conducted in the Campaigns in Africa from 1961 to 1974.
Grossi, Rafaeli Sagrilo. "Videonistagmoscopia digital com lente de contato para identifica??o de movimentos oculares e apoio ao topodiagn?stico da vertigem posicional parox?stica benigna." Pontif?cia Universidade Cat?lica do Rio Grande do Sul, 2016. http://tede2.pucrs.br/tede2/handle/tede/6988.
Full textMade available in DSpace on 2016-10-10T17:13:24Z (GMT). No. of bitstreams: 1 DIS_RAFAELI_SAGRILO_GROSSI_PARCIAL.pdf: 731531 bytes, checksum: 2a61d4b51ae149bd92ef4ac8256b7072 (MD5) Previous issue date: 2016-04-29
Benign paroxysmal positional vertigo (BPPV) is characterized by vertigo crisis, triggered by sudden head position changes, associated with the appearance of paroxysmal positional nystagmus. The characterization of torsional nystagmus has fundamental importance while conducting a patient with BPPV, because it turns possible to identify the affected semicircular channel, as well as the physiopathological mechanism involved. However, the majority of existing videonystagmography devices are not capable of identifying these torsional movements with the required precision. This work aims to develop and test a method to model and identify torsional eye movements, when present. This new model uses a videonystagmograph prototype, comercial ophthalmic contact lens with geometric figures and a computer program, which was specially designed with this objective. Complementarily, a webapp program has also been created to support the topodiagnosis of the BPPV. Subjects with BPPV and without BPPV have been evaluated. The subjects have undergone the Dix-Hallpike maneuver, using the contact lens with geometrical figures on the left eye and the capture device. Among these evaluations, forty videos have been recorded (23 with counter-clockwise rotating movement phenomena, 10 clockwise and 7 videos with eye at rest). The extracted videos were analyzed with the developed software. The success rate in classifying the direction of the rotating movement (counter-clockwise or clockwise) and the resting position was evaluated. The accuracy of the software in correctly finding the geometric lines of the ophthalmic lens was also evaluated. Among the forty analyzed videos, the software had a success rate of 85% (70-94%) in identifying direction of movement or at rest; considering only the success rate in direction of movement, the total was 81% (64-93%). The accuracy in the measuring of the interest zone of the frames was 82,2% (81,5-82,8%) with p<0,05 significance level. Therefore, the new developed model should be able to have an important part on the topodiagnosis of the BPPV in the future, providing a more precise and effective therapeutic management to the patients with this disease.
A vertigem posicional parox?stica benigna (VPPB) ? caracterizada por crises de vertigem, desencadeadas por mudan?as bruscas de posi??o da cabe?a, associada a um nistagmo posicional parox?stico. A caracteriza??o do nistagmo rotacional ? de fundamental import?ncia na condu??o do paciente com VPPB, pois ? atrav?s das caracter?sticas do nistagmo que ? poss?vel identificar o canal semicircular acometido, bem como o mecanismo fisiopatol?gico envolvido. Por?m, a maioria dos dispositivos de videonistagmoscopia existentes n?o s?o capazes de identificar com precis?o esses movimentos rotat?rios. A proposta deste trabalho foi desenvolver e testar um novo modelo de quantifica??o de movimentos oculares rotat?rios quando presentes. Este novo modelo utiliza prot?tipo de videonistagmosc?pio, lente de contato oft?lmica comercial com figuras geom?tricas e o desenvolvimento de um software especificamente para esta finalidade. De forma complementar, uma WebApp tamb?m foi criada para auxiliar no topodiagn?stico da VPPB. Participaram do estudo 4 indiv?duos com VPPB e 4 sem VPPB. Os sujeitos foram submetidos ? manobra de Dix-Hallpike, utilizando a lente de contato com formas geom?tricas no olho esquerdo e o dispositivo de captura. Dessas manobras, foram gravados 40 v?deos (23 com fen?menos de movimento rotat?rio anti-hor?rio, 10 no sentido hor?rio e 7 v?deos com olho em repouso). Os v?deos extra?dos foram analisados com o software criado. Foi analisada a taxa de acertos na classifica??o da dire??o do fen?meno de movimento rotat?rio (anti-hor?rio ou hor?rio) quando presente ou v?deo repouso. Tamb?m foi avaliada acur?cia do software em encontrar corretamente as marcas geom?tricas da lente oft?lmica. Dos 40 v?deos analisados, o software obteve como taxa de acerto da dire??o ou repouso valor de 85% (70-94%); considerando-se apenas a taxa de acerto da dire??o, o valor foi de 81% (64-93%). A acur?cia na medida da zona de interesse dos frames foi de 82,2% (81,5-82,8%) com n?vel de signific?ncia de p<0,05. Assim, o novo modelo desenvolvido poder? no futuro ter um papel importante no aux?lio do topodiagn?stico da VPPB, proporcionando aos doentes com esta enfermidade um manejo terap?utico mais preciso e eficaz.
Dias, Andreia Manuela Martins. "Suspeita de oclusão do ramo da veia central da retina, adaptação de lentes de contacto em hipermétrope astigmata, estrabismo acomodativo." Master's thesis, Universidade da Beira Interior, 2013. http://hdl.handle.net/10400.6/1663.
Full textThe preparation of this report represents the culmination of the Optometry in Vision Sciences MSc carried out between October 2012 and January 2013 in the clinic OcularEyeCare, located in Aveiro. This internship has as main goals the acquisition of new skills, knowledge consolidation, and contact real clinical cases without direct supervision. This experience allowed me as well the development of communication and interpersonal skills, and to understand how this particular clinic works. Throughout this period of practical application and training many different areas of optometry were approached including pediatric optometry, geriatric optometry, low vision, strabismic and non-strabismic binocular vision, contact lens and ocular health. Following up real cases allowed me to realize in a practical way the various clinical cases framed on approached topics, and lastly performing optometric examinations without supervision. In this rapport three real cases are studied: one with suspect retinal vein branch occlusion, other with adaptation of contact lenses for astigmatic hyperopia and finally a case of accommodative strabismus.
Engel, Elis Regina. "Avaliação da qualidade na produção de lentes de contato coloridas através do QFD : desdobramento da função qualidade." reponame:Biblioteca Digital de Teses e Dissertações da UFRGS, 2004. http://hdl.handle.net/10183/5042.
Full textVaz, Rodolfo Alberto Lopes Soares da Fonseca. "Facetas em lente de contacto : considerações e implicações clínicas." Master's thesis, 2018. http://hdl.handle.net/10400.26/25580.
Full textA Medicina Dentária tem seguido uma evolução conservadora, no que toca à preocupação em preservar estrutura dentária, apostando, cada vez mais, em procedimentos minimamente invasivos. As facetas em lente de contacto são representativas desta tendência, na medida em que permitem o alcance de resultados altamente estéticos, conservando o máximo de tecido dentário. Estas restaurações cerâmicas apresentam uma espessura mínima, sendo indicadas para a correcção de descolorações, diastemas, dentes conoides entre outra (Okida, Filho, Barão, dos Santos & Goiato, 2012, Magne & Belser, 2002). Podem ser confeccionadas a partir de vários tipos de cerâmicas, mediante processos manuais ou industriais, possibilitando uma manipulação das propriedades ópticas e mecânicas, consoante o caso a reabilitar. A cimentação adesiva permite obter uma retenção duradoura, sem necessidade de preparos invasivos (Shillingburg et al., 2012). A possibilidade de devolver o sorriso aos pacientes, através de procedimentos não invasivos, torna este tipo de reabilitação muito procurado. Contudo, o sucesso a longo prazo depende de uma selecção criteriosa e gestão de expectativas adequada, para além, de um domínio técnico do protocolo clínico. Mediante a falta de um sistema bem definido, quanto à uniformidade de actuação, serão necessários mais ensaios clínicos, de forma a estabelecer um protocolo homogéneo, que dê mais segurança ao Médico Dentista na aplicação desta técnica.
Dentistry has been pursuing a conservative evolution, regarding the concern for dental tissue preservation, taking a gamble, each and every time, on minimally invasive procedures. Contact lens veneers represent this trend, in that they reach highly esthetic goals, conserving as much dental tissue as possible. These ceramic restorations posess minimum thickness and are indicated for the correction of discolorations, diastema and peg teeth (Okida, Filho, Barão, dos Santos & Goiato, 2012, Magne & Belser, 2002). They can be manufactered from various types of ceramics, by manual or industrial means, allowing the manipulation of optic and mechanical proprieties, depending on the case in question. Adhesive luting grants a durable retention, without the need for invasive preparations (Shillingburg et al., 2012). The possibility of returning patients their smile, through non-invasive procedures, makes this rehabilitation very sought after. However, long-term success depends on a judicious selection and adequate expectation management, in addition to a technical domain of clinical protocol. In the lack of a well defined system, regarding the consistency of the procedure, there will be a need for more clinical trials, in order to establish a uniform protocol that provides the dentist more assuredness in the application of this technique.
Marçal, Elisa Ferreira. "Suspeita de Edema Macular, Insuficiência de Divergência, Adaptação de Lente de Contacto Hidrófila Tórica em Anisométrope." Master's thesis, 2016. http://hdl.handle.net/10400.6/7763.
Full textDuring the eight months Internship any Clinical Center and Experimental in Vision Sciences (CCECV) were analyzed several clinical cases. The present stage report describes three Clinical Cases that have been flagged: a case of ocular pathology, a case concerning the deviations in binocular vision and finally a case related to a contact lens adaptation. The clinical case of ocular pathology refers to a 69-year-old patient diagnosed with diabetes mellitus type II, with a suspicion of Macular Edema, which led to its referral to the Ophthalmology specialty. The second clinical case exemplifies the occurrence of change of binocular vision. After conducting several tests of visual function has been detected Divergence Insufficiency, a on the 15 year-old patient. The optometric examinations also revealed the presence of a decompensated hyperopia. Thus, we used the visual therapy plan for the Divergence of Insufficiency and appealed to the correction of ametropia. The third and final clinical case described in this report relates the adaptation of a contact lens Hydrophilic Toric at an anisométrope patient. The same had an anisometropia amblyopia. After successfully performed the treatment, the patient continued to express difficulty adapting to their usual contact lenses, so were adapted a new ones. The last clinical case aroused a special interest in the area of Anisometropia that led to the development of a pilot study that will also be presented in this report.
Filipe, Marcelo de Matos. "Adaptação de Lente de Contacto RPG num Queratocone, Insuficiência de Convergência e Suspeita de DMRI Seca Marcelo De." Master's thesis, 2018. http://hdl.handle.net/10400.6/10210.
Full textA realização do presente relatório teve como objetivo a análise de três casos clínicos, Adaptação de Lente de Contacto RPG num Queratocone, Insuficiência de Convergência e Suspeita de DMRI com os quais tive contacto durante o estágio curricular no mestrado em Optometria e Ciências da Visão da Universidade da Beira Interior, desenvolvido no período de seis meses, e que teve lugar na Ótica Lucas, Lda em Castelo Branco. O Queratocone é um distúrbio da córnea que leva à perda de acuidade visual, e que geralmente está associado a sintomas como, por exemplo, a perceção de múltiplas imagens fantasmas, cefaleias e visão em diplopia. O exame complementar da topografia corneal é fundamental na deteção desta condição. O tratamento pode passar pela adaptação de lente RGP específica para o Queratocone. A Insuficiência de Convergência é uma anomalia binocular que se caracteriza pela incapacidade de manter uma convergência sem esforço, ou seja, a incapacidade de manter um alinhamento binocular em objetos próximos do sujeito. O tratamento pode passar por treino visual que ajuda a que a convergência seja feita com menor esforço, eliminando as queixas do paciente. A DMRI é uma doença degenerativa da retina que se manifesta geralmente depois dos 50 anos e que é uma das maiores causas de cegueira nesta faixa etária. Pode apresentar duas formas distintas: a seca e a húmida. A deteção precoce é fundamental no controlo da doença, visto que a DMRI não possui cura. Aquando a deteção das alterações do fundo ocular, o paciente deve ser reencaminhado para o Médico Oftalmologista. Neste trabalho foi adaptada uma lente RGP Rose-K num paciente com Queratocone, executou-se um plano de terapia visual para um paciente com insuficiência de Convergência e encaminhou-se um paciente com suspeita de DMRI para o Médico Oftalmologista
Loureiro, Diana Raquel Correia. "Suspeita de degenerescência macular relacionada com a idade, endoforia básica, adaptação de lentes de contacto rígidas permeáveis aos gases." Master's thesis, 2016. http://hdl.handle.net/10400.6/7762.
Full textThe traineeship held at the Clinical and Experimental Center in Vision Sciences (CCECV), under the guidance of Prof. Dr. Francisco Brardo, lasted nine months, starting in October 2015 and finalized in June 2016. This report is composed of three cases, an eye disease, a binocular vision and a contact lens adaptation. The case of ocular pathology is suspected to be related to Macular Degeneration with age, while the case of binocular vision is related to the presence of a Basic Endoforia. In the case of adjustment of contact lenses, it was selected to adapt a case of Rigid Gas Permeable contact lens. The following report presents all tests performed for each case, as well as their analysis, discussion and action in the field of optometry and vision sciences.
Rodrigues, Francisco de Almeida Sá de Brito. "Therapeutic strategies for the treatment of bacterial keratitis." Master's thesis, 2016. http://hdl.handle.net/10451/35840.
Full textA Queratite Bacteriana é uma doença que se está a espalhar por todo o mundo, especialmente associada ao uso prolongado de lentes de contacto. O tratamento desta doença consiste na administração tópica de colírios contendo antibióticos. Contudo, a biodisponibilidade destas formulações é consideravelmente baixa devido à lavagem causada pelas lágrimas. O objectivo do presente trabalho é fazer um resumo das opções terapêuticas actuais e dos avanços recentes relativos ao tratamento desta patologia, ainda subestimada tanto por doentes como por profissionais de saúde, e que silenciosamente se vai assumindo como um problema de saúde pública mundial que anualmente custa 175 milhões de dólares em despesas directas com saúde, apenas nos Estados Unidos da América (1).
Bacterial Keratitis is a disease that is spreading all over the world specially associated to the prolonged use of contact lenses. Treatment of this condition usually consists on topical administration of eye drops containing antibiotics. Nonetheless, the bioavailability of such formulations is considerably low due to the washout caused by tears. The aim of this work is to summarize the current therapeutic options and recent advances regarding the treatment of this underestimated condition that, silently, is setting its place as a global public health problem which annually costs $175 million in direct health care expenditures, only in the United States of America (1).
"Colonización fungica de lentes de contacto." Universitat Politècnica de Catalunya, 1998. http://www.tesisenxarxa.net/TDX-0608110-133427/.
Full textAzevedo, Sara Maria Menezes Nogueira Rosas. "Lentes de contacto: reabilitação estética dentária." Master's thesis, 2018. http://hdl.handle.net/10284/7424.
Full textThis monograph aims to make a literary review on aesthetic rehabilitation using the use of dental contact lenses (ceramic facets). In the accomplishment of this work we resorted to the library of the Faculty of Sciences of the Health of the Fernando Pessoa University and the databases of online: Pubmed; Scielo; Science Direct; B-on and Google Scholar including bibliographies in Portuguese, English and Spanish. The growing importance given to the image in today's society in which the smile plays a fundamental role that works as a maximum exponent and impactful "business card" that can facilitate success at professional, social or even personal level. Thus, there is an extremely high degree of requirement in the dental rehabilitation area. The improvement in fixation (adhesive / cementation) allowed the creation of restorative pieces of minimal thicknesses such as contact lenses that revolutionized the paradigm of dental medicine.
Carvalho, Ana Luísa da Silva. "Estudo do Atrito em Lentes de Contacto Gelatinosas." Master's thesis, 2019. http://hdl.handle.net/10316/88054.
Full textUnderstanding the biotribology involved between contact lenses and the eye, namely the friction between the eyelid and the surface of the contact lens during the blink movement, is a crucial factor in avoiding irritation, discomfort and other eye infections.The aim of the present dissertation is to investigate the tribological behavior of soft contact lenses under different contact conditions. Since there is no commercially available equipment, a tribometer has been developed for this purpose, which operates as a pendulum with vibration horizontal movement and can be considered a vibratory mass - spring - damper mechanical system. The friction assessment method is based on the evaluation of the free damping vibration movement, of the mass - spring system, induced by a mechanical impulse. The contact with the lenses acts as a supplementary dissipation of energy and the friction is determined by inverse analysis, compared to the analytical equation of movement.Thus, the main objectives of this dissertation were: to verify the principles and applicability of the experimental method in contact lenses under different contact conditions, to validate the results and to study the effect of aging of contact lenses in the friction.Four different commercial contact lenses were tested under lubrificated conditions, being the contact lubrificated with a buffered saline solution, the applied normal load was varied between 21 and 62 mN and the sliding velocities between 100 and 200 mm/s. The friction model, adjusted from the experimental results, includes a Coulomb part more a viscous component.In all cases, a good linearity of the results of the friction force was verified as a function of the normal force, so the first friction law can be applied to determine the value of the coefficient of friction. For the new contact lenses, coefficient of friction values were obtained between 0,0051 and 0,0275, the hydrogel lens presented the highest value in comparison with silicone-hydrogel and hypergel lens.The aging procedure of contact lenses was simulated by a cycling process considering that the main parameter influencing the material surface is the transition between the closed and open eye and the exposure to environmental aggressions, particularly ultraviolet radiation. The values of the coefficient of friction and modulus of elasticity before and after the aging process were compared and was verified the increase of both parameters for all contact lenses. The hydrogel lens was the least affected by aging and the silicone - hydrogel lens based on delefilcon A was the one that showed the least stability of properties.The experimental method was validated by comparing the results with obtained in an alternative linear motion tribometer. There was an equal behavior in hierarchical terms of the coefficient of friction. With this, it was concluded that the experimental method and the inverse analysis technique is an efficient and reliable method in characterizing the friction of materials such as contact lenses.
A compreensão da biotribologia envolvida entre as lentes de contacto e o olho, nomeadamente o atrito entre a pálpebra e a superfície da lente de contacto durante o movimento de pestanejar, é um fator crucial para evitar irritação, desconforto e outras infeções oculares.O objetivo da presente dissertação é investigar o comportamento tribológico de lentes de contacto gelatinosas sob diferentes condições de contacto. Como não há equipamento disponível comercialmente, foi desenvolvido um tribómetro para o efeito, que opera como um pêndulo com movimento horizontal de vibração e pode ser considerado um sistema mecânico vibratório massa - mola - amortecedor. O método de avaliação do atrito é baseado na avaliação do movimento livre de vibração de amortecimento, do sistema massa - mola, induzido por um impulso mecânico. O contacto com as lentes de contacto atua como uma dissipação suplementar de energia e o atrito é determinado pela análise inversa por comparação com a equação analítica de movimento. Assim, os principais objetivos desta dissertação foram: verificar os princípios e aplicabilidade do método experimental em lentes de contacto gelatinosas sob diferentes condições de contacto, validar os resultados e estudar o efeito do envelhecimento das lentes de contacto no atrito. Foram testados quatro tipos de lentes de contacto disponíveis comercialmente sob condições de contacto lubrificado com solução salina tamponada, com cargas normais aplicadas entre 21 e 62 mN e velocidades de deslizamento de 100 a 200 mm/s. O modelo de atrito, ajustado a partir dos resultados experimentais, inclui uma parte de Coulomb mais um componente viscoso.Em todos os casos, verificou-se uma boa linearidade dos resultados da força de atrito em função da força normal, logo pode-se aplicar a primeira lei de atrito para determinar o valor do coeficiente de atrito. Para as lentes de contacto novas, obtiveram-se valores de coeficiente de atrito entre 0,0051 e 0,0275, sendo que a lente de hidrogel, em comparação com as de silicone - hidrogel e de hypergel, apresentou o maior valor. O procedimento de envelhecimento das lentes de contacto foi simulado por um processo de ciclagem, onde se considerou que o principal parâmetro que influencia a superfície do material é a transição entre o olho fechado e aberto e a exposição a agressões ambientais, particularmente à radiação ultravioleta. Foram comparados os valores do coeficiente de atrito e do módulo de elasticidade antes e após o processo de envelhecimento e verificou-se o aumento de ambos os parâmetros para todas as lentes de contacto. A lente de hidrogel foi a menos afetada pelo envelhecimento e a lente de silicone - hidrogel à base de delefilcon A foi a que apresentou a menor estabilidade das propriedades.O método experimental foi validado por comparação dos resultados com os obtidos num tribómetro de movimento linear alternativo. Verificou-se um comportamento igual em termos hierárquicos dos valores do coeficiente de atrito e, portanto, conclui-se que o método experimental e a técnica de análise inversa é um método eficaz e fidedigno na caracterização do atrito de materiais como o das lentes de contacto.
Peixoto, Maria Francisca Pinto. "Promover o uso saudável das lentes de contacto." Master's thesis, 2014. http://hdl.handle.net/1822/29405.
Full textAtravés deste estudo, procurou-se identificar nos usuários de lentes de contacto (LC) portugueses as principais falhas na sua manutenção. Neste sentido, após uma análise cuidada do estado da arte, procedeu-se à elaboração de um questionário. Este foi distribuído em algumas óticas de Portugal. Deste trabalho resultou um total de 270 inquéritos válidos. Esta é uma investigação observacional e descritiva, categorizada por um inquérito epidemiológico transversal. Genericamente, esta tese tornou possível identificar vários aspetos negligenciados pelos pacientes, entre eles, a higienização e os cuidados de saúde ocular, tais como: não esfregar as lentes antes de as colocar no estojo, não mudar o líquido diariamente, adiar as consultas com o profissional de saúde e a menor frequência de lavagem e substituição do estojo, etc. Verificou-se ainda que os pacientes que utilizam LC há mais anos prolongam o uso diário das lentes e podem apresentar maior probabilidade de ter complicações oculares. Os pacientes do sexo feminino mostraram em geral um melhor cumprimento que os do sexo masculino, nomeadamente ao lavarem com mais frequência o estojo, bem como na substituição das LC no prazo recomendado. Verificou-se uma tendência para um cumprimento inferior para os usuários de LC convencionais e na Região Centro, Lisboa e Sul. Na generalidade, verificou-se que os utilizadores de LC estão conscientes quanto à importância da higienização das mãos no manuseamento das LC e na não utilização das mesmas durante a noite. Tornou-se evidente que os pacientes estão pouco alertados para as complicações inerentes ao uso das lentes, mas, de uma forma geral, cumprem as regras de higiene e manutenção aconselhadas, ainda que subsistam determinados aspetos a melhorar, como a limpeza das LC e dos estojos. É neste contexto que o papel do profissional é fundamental, no sentido de informar e corrigir os pacientes acerca duma correta utilização das LC e dos produtos associados.
The purpose of this study was to identify in the Portuguese population, in users of contact lenses (CL), major failures in maintaining them. After a careful analysis of the state of the art, I proceeded to draw up a questionnaire. This questionnaire was distributed in some optics in Portugal. This work resulted in a total of 270 valid surveys. This research is in an observational and descriptive study, categorized by an epidemiological investigation. Generally, this thesis made it possible to identify several aspects overlooked by patients, among them, the cleaning and care of eye health, such as: do not rub the lenses before putting them in the case, do not change the fluid daily, postponement of the consultations with health professional and less frequent cleaning and replacement of the professional kit. It was also found that patients using LC longer, extend the daily use of the lens, and may be more likely to have ocular complications. The female patients showed, in general, better compliance than males, particularly to wash more often the case, as well as the replacement of the LC recommended term. There was a tendency toward lower compliance for users of conventional LC and in the Central Region, Lisbon and South. In general, it was found that LC users are aware of the importance of hand hygiene in the handling of LC and non-use of the same overnight. It became apparent that patients are alerted to some complications inherent in the use of lenses, but in general , everyone fulfill with the rules of hygiene and recommended maintenance, still subsisting improve certain aspects, such as cleaning the LC and the cases. It is in this context that the role of the health professional is crucial to inform and correct patients concerning a correct use of the LC and associated products.
Raínho, Vera Mónica Ramos da Silva. "Preparação e Caracterização de membranas para lentes de contacto pós-cirúrgicas." Master's thesis, 2017. http://hdl.handle.net/10316/82866.
Full textA eficiência da administração de fármacos na terapia ocular após intervenções cirúrgicas é um dos grandes fatores que condiciona a recuperação dos pacientes. Nos dias de hoje, a administração de fármacos nestes casos é realizada na forma de colírios. No entanto, este método mostra-se muito ineficiente, surgindo o uso de sistemas de libertação controlada de fármacos como uma possível alternativa bastante promissora. No decorrer deste trabalho foram desenvolvidas membranas à base de acrilatos para serem usadas como sistemas de libertação controlada de um fármaco (sob a forma de lentes de contacto), sendo o fármaco selecionada a moxifloxacina (MFX), um antibiótico muito utilizado no pós-operatório da terapia ocular. Estas membranas foram desenvolvidas através do método de polimerização na massa. Deste modo foram preparadas membranas com diferentes monómeros na sua constituição. Uma vez que o desconforto causado pela radiação solar é outro dos fatores que influencia a recuperação pós-operatória, com o intuito de minimizar este desconforto, também foram incorporados corantes fotocrómicos nas membranas desenvolvidas. A membrana com melhores propriedades, preparada a partir de acrilato 2-etil-hexilo (EHA), metacrilato de metilo (MMA), peróxido de benzoílo (BPO) e dimetacrilato de etilenoglicol (EGDMA), designada AMB 7, foi caracterizada e nela foi incorporada MFX e corantes fotocrómicos, por oclusão. Com base nesta formulação, foram desenvolvidas mais duas formulações, a ABM 7.1 e ABM 7.2, com o intuito de avaliar a influência do aumento do agente de reticulação EGDMA nas propriedades finais das membranas. Foi ainda preparada uma membrana incluindo na formulação o monómero metacrilato de 2-hidroxietilo (HEMA), designada ABM 10, com a finalidade de aumentar a hidrofilicidade da membrana. Nestas membranas, somente se incluiu MFX por oclusão.As membranas preparadas foram caracterizadas quimicamente por espectroscopia de infravermelho com transformada de Fourier (FTIR), confirmando o sucesso da polimerização. Através da análise termogravimétrica (TGA) constatou-se a elevada estabilidade térmica dos materiais, sendo superiores a 350ºC.Os ângulos de contato, a transmitância e o teor de água das quatro membranas selecionadas foram determinados. No que diz respeito a molhabilidade das membranas determinado pela medição do ângulo de contacto, a ABM 7 foi a que apresentou melhores resultados (45º), dentro do intervalo de valores de lentes de contacto comerciais. Quanto à transmitância, a ABM 7 confere um maior grau de proteção relativamente a radiação UV ao passo que a ABM 7.1, apresenta melhores resultados relativamente à sua transparência. As membranas que contem corantes fotocrómicos incorporados, foram as que apresentaram maior proteção a radiação UV, no entanto, a sua coloração resulta numa diminuição da transparência das membranas. Analisando ainda o teor de água, os valores obtidos foram inferiores a 2%, sendo a ABM 10 a membrana que apresentou a maior capacidade de absorção de água, um valor muito baixo para uma aplicação como lente de contacto. Os resultados da libertação da MFX nos três sistemas de libertação que foram estudados (ABM 7, ABM 7.2 e ABM 10), permitiram concluir que a membrana ABM 7.2 é a que apresenta melhores resultados, uma vez que apresenta um máximo de libertação ao final de quatro dias e apresenta o maior valor de massa libertada de moxifloxacina.
One of the main factors that determines the recovery of patients after ocular surgery interventions is based on the efficiency of drug administration. Nowadays, drug administration is usually made using eye drops. However, this system showed to be ineffective. Therefore, the use of ocular controlled drug delivery system is being used as an alternative. The present work is based on the development of new acrylate based membranes to be used as drug delivery systems in the form of soft contact lenses. Moxifloxacin (MFX) was the selected drug since it is an antibiotic widely used in ocular therapy. The membranes were prepared by bulk polymerization, using different monomers. The increase of sensibility to the solar radiation is one of the consequences after an ocular surgery. The incorporation of photochromics compounds in the acrylic based membranes was thus performed to diminish this discomfort. The membrane ABM 7 was developed based on 2-Ethylhexyl acrylate (EHA), methyl methacrylate (MMA), benzoyl peroxide (BPO) and Ethylene glycol dimethylacrylate (EGDMA), showed the best properties and was fully characterized since it showed the best properties. To study the influence of the crosslinking agent EGDMA in the final properties of the membranes, two other membranes based on ABM 7 were developed – ABM 7.1 and ABM 7.2. ABM 10 was prepared with 2-Hydroxyethyl methacrylate (HEMA) to enhance the hydrophilic character of the membrane. Only the best membranes – ABM 7, ABM 7.1, ABM 7.2 and ABM 10 – were selected for an extensive characterization and for MFX loading by occlusion. Photochromics incorporation was only performed in ABM 7. The membranes were chemical characterized by ATR-FTIR which confirms the polymerization reaction. Also, the thermal stability of the membranes was established, with Td higher than 377ºC, by TGA analysis. Water contact angles, transmittance and water content were also determined. ABM7 showed the lowest contact angle (44º), very close to the commercial soft contact lenses. Concerning the transmittance of ABMs, ABM 7 proved to have the higher capacity to protect the eyes form the UV radiation. On the other hand, ABM 7.1 was the most transparent membrane. For the membranes containing the photochromics, an enhancement of the protection of UV radiation was observed, however, the strong coloration of the membranes after UV exposure results in the loss of transparency. Concerning the water content of the membranes they were extremely low, having is highest value (2%) with ABM 10. The MFX release in ABM 7, ABM 7.2 and ABM 10 was studied and ABM 7.2 revealed to be the formulation with the maximum MFX release at the end of 4 days and with the higher amount of MFX released.
Compañy, Vidal José Luis. "Alteraciones de las lentes de contacto producidas por fármacos." Doctoral thesis, 1991. http://hdl.handle.net/10045/5296.
Full textJesus, Sónia Cláudia Martins. "Desempenho in vivo da humectabilidade das lentes de contacto." Master's thesis, 2018. http://hdl.handle.net/1822/65153.
Full textO uso de lentes de contacto (LC) tornou-se um dos meios mais solicitados para a compensação de erros refrativos, podendo ser para a prática clínica um fator adicional para o aparecimento de sinais e sintomas de secura ocular. A humectabilidade é uma propriedade dos materiais das LC altamente importante, que rege a interação entre a superfície ocular e a superfície da LC. O objetivo da investigação foi compreender melhor de que forma as características dos materiais das LC interferem com a humectabilidade e também observar como é que a humectabilidade influência a performance das LC e o conforto durante o seu uso. Este é um estudo longitudinal randomizado aberto que reúne os resultados obtidos ao longo de 3 meses em 38 pacientes. Foram avaliadas quatro LC usadas na prática clínica: três LC de Silicone-Hidrogel, Air Optix Aqua™ (Lotrafilcon B), Biofinity™ (Comfilcon A), Dailies Total1® (Delefilcon A), e uma LC de hidrogel convencional Dailies® AquaComfort Plus® (Nelfilcon A). O sistema de limpeza utilizado nas lentes de substituição mensal foi a solução única, Optifree®. Foi avaliado o tempo de rutura lacrimal não invasivo (TRLNI) e as medidas da humectabilidade foram obtidas imediatamente após a colocação das lentes (TRLPL1), após um dia para usuários de lentes diárias (TRLPL2), e após um mês para usuários de lentes mensais. O instrumento utlizado foi o ICP Tearscope (SBM Sistemi, Italy) e a técnica foi baseada na avaliação da estabilidade da película lacrimal pré lente de forma não invasiva.Para além dos dados recolhidos da humectabilidade foram também avaliadas a sintomatologia da superfície ocular e o conforto que a lente proporcionou ao participante. Embora de diferentes materiais e respetivas características, a humectabilidade diminuir em todas as lentes, no entanto essas diferenças não são estatisticamente significativas. A estabilidade lacrimal sobre a lente é menor do que quando avaliada sobre o olho e é dependente do material. A lente do material Lotrafilcon B foi a lente menos idêntica à superfície corneal, que foi onde se observou maior diferença entre o TRLNI e o TRLPL. Os resultados da avaliação do conforto mostraram uma tendência dos participantes a classificar como lentes mais confortáveis aquelas em que a variação do tempo de rutura lacrimal foi menor. A Delefilcon A foi considerada a lente mais confortável. Esta possível relação pode ter importância clínica, na compreensão dos insucessos de adaptação e posterior abandono.
The use of contact lenses (CL) has become the most requested way for refractive error compensation, bringing to clinic practice signals and symptoms of ocular dryness. The wettability is a material propriety of a CL extremely important, that reacts to the interaction between the ocular surface and the CL surface. The goal of the study is to better understand in which way the material characteristics of the CL interfere with the wettability and to observe how the wettability affects the performance of the CL and comfort during use. This is an open randomized longitudinal study that gathers the obtained results on a period of three months on 38 patients. There were tested four of the most used contact lenses the Silicone-Hydrogel, Air Optix Aqua™ (Lotrafilcon B), Biofinity™ (Comfilcon A), Dailies Total1® (Delefilcon A), and one CL of conventional hydrogel Dailies® AquaComfort Plus® (Nelfilcon A). The cleaning system used for the monthly disposable CL was the multipurpose solution, Optifree® (Alcon). It was measured the Non Invasive Break Up Time (NIBUT or TRLNI)) and the measurements of wettability were obtained immediately after CL insertion (TRLPL1) and after one day for daily users and one month for monthly lens wearers (TRLPL2). The instrument used was ICP Tearscope (SBM Sistemi, Italy) and the technique was based on evaluation the stability of the pre-lens tear film non-invase.In addition to the data collected on wettability, the symptoms of the ocular surface and the comfort that the lens provided to the participant were also evaluated. Although the difference in materials and characteristics, the wettability reduced in all lenses despite no significant statistically differences found. The lacrimal stability over the lens is less when measured over the eyes and is material dependent. Lotrafilcon B was the lens less identical to the corneal surface, which was where the greatest difference was observed between the TRLNI and the TRLPL The results evaluating the comfort showed a tendency for the participants to classify as more comfortable lens those in which the variation of lachrymal rupture time was smaller. A Delefilcon A was considered to be the most comfortable lens.This possible relation may have clinical importance, in the understanding of the failures of adaptation and later abandonment.
Carloto, Rui Manuel Cepeda. "Insuficiência de Convergência Lentes de Contacto Tóricas Retinopatia Diabética." Master's thesis, 2013. http://hdl.handle.net/10400.6/4512.
Full textThis work consists in the description of three clinical cases, of my personal clinical practice, holding the technical improvement on Optometry. The first clinical case (convergence insufficiency) is very common, and it’s present in all ages, and it’s very recurrent in my clinical practice successfully solved after several visual therapy sessions. The second clinical case, it’s a contact lens case description of Contact Lenses intolerance. Being Diabetes one of the diseases that affect more the vision, it is very interesting to approach this theme. Whit this, my third clinical case, is about diabetic retinopathy, and it’s very common in my clinical practice.
Marques, Lília Catarina Dias. "Alterações na resposta acomodativa em jovens com o uso de lentes de contacto multifocais." Master's thesis, 2019. http://hdl.handle.net/1822/66600.
Full textA base de atuação das lentes de contacto multifocais na redução da progressão da miopia assentam na hipótese de que o desfocado hipermetrópico retiniano acelera o crescimento axial do olho, enquanto o desfocado miópico abranda essa progressão. Desta hipótese surgiram duas teorias para o mecanismo de atuação das lentes de contacto: a capacidade alterar o desfocado periférico no sentido miópico; ou a correção do elevado atraso acomodativo em jovens com endoforia em visão de perto (a correção do atraso acomodativo permitiria diminuir o desfocado hipermetrópico, enquanto manteria a visão binocular equilibrada). O principal objetivo deste trabalho consistiu em avaliar a influência da diminuição do diâmetro de zona interna em lentes de contacto bifocais de centro-longe, na resposta acomodativa. Uma das lentes estudadas apresentava um diâmetro de zona interna de visão de longe de 2,10 mm, e a outra 4,00 mm. A adição presente em ambas as lentes era de +2,00D. No estudo participaram 17 jovens adultos, com idade média de 26,15±6,06 anos, e esfera equivalente -2,50±1,75D. A resposta acomodativa foi medida monocularmente com um autorefratómetro de campo aberto adaptado com um sistema de Badal. Os dois desenhos de lentes de contacto bifocais foram simultaneamente adaptados a cada sujeito, ficando uma lente no olho direito e a outra no olho esquerdo, segundo tabela de aleatorização. A resposta acomodativa foi medida para as seguintes vergências: 1D (1m), 2D (50 cm), 3D (33cm), 4D (25cm) e 5D (20cm). Como medida de controlo utilizou-se a resposta acomodativa sem lente de contacto. Registou-se ainda a variação da acuidade visual de alto e baixo contraste com e sem a utilização das lentes de contacto bifocais. Os resultados obtidos sugerem que sujeitos jovens adaptados com uma lente de contacto bifocal com um diâmetro de zona interna de visão de longe mais estreito, reduzem a resposta acomodativa de forma clinicamente significativa. As lentes bifocais parecem não afetar a acuidade visual de alto contraste, alterando apenas de forma significativa a acuidade visual de baixo contraste.
The basis of action of multifocal contact lenses in reducing myopia progression is set on the hypothesis that retinal hyperopic defocus accelerates axial eye growth, while myopic defocus slows it. From this hypothesis emerged two theories for action mechanism of contact lenses: the ability to change the peripheral defocus in the myopic sense; or correction of the high accommodative lag in young people with near vision esophoria (correction of accommodative lag would allow compensate the hyperopic defocus while keeping the binocular vision simply). The aim of this study was to evaluate the influence of the inner zone distance diameter of bifocal contact lenses on the accommodative response. One of the lenses studied had an inner zone diameter of 2,10 mm, and the other 4,00 mm. The addition present on both lenses was +2,00D. Seventeen young adults participated in the study, with a mean age of 26,15 ± 6,06 years and an equivalent sphere -2,50 ± 1,75D. The accommodative response was measured monocularly with an open field autorefractometer adapted with a Badal system. Both designs of bifocal contact lenses were simultaneously adapted to each subject, one lens in the right eye and the other in the left eye, according to the randomization plan. The accommodative response was measured for the following vergences: 1D (1m), 2D (50cm), 3D (33cm), 4D (25cm) and 5D (20cm). As a control measure, the accommodative response without contact lens was used. High and low contrast visual acuity variation with and without the use of bifocal contact lenses was also recorded. The results obtained suggest that young subjects fitted with a small inner zone distance bifocal contact lens, reduce accommodative response in a clinically significant way. Bifocal contact lens does not appear to affect high contrast visual acuity but reduced significantly low contrast visual acuity.
Diaz-Rey, José Alberto. "Morformetría corneal en queratoconos, lentes de contacto y cirugía refractiva." Doctoral thesis, 2007. http://hdl.handle.net/1822/7131.
Full textLos conocimientos de las características morfométricas, biomecánicas y fisiológicas de la córnea son básicos para el estudio de los cambios que se producen en la córnea con el sexo, la edad y el envejecimiento, para el seguimiento de procesos tales como la adaptación de lentes de contacto o la respuesta corneal a sus materiales y geometrías, para el estudio de determinadas patologías como el queratocono y para la corrección de ametropías mediante cirugía refractiva, que constituyen los objetivos de este trabajo. Para aproximarse a dicho conocimiento, este estudio analiza el espesor y la curvatura de la córnea en las muestras poblacionales más adecuadas según la finalidad, utilizando para ello la biometría ultrasónica, el sistema de análisis corneal Orbscan II y el videoqueratoscopio Eye Sys, fundamentalmente. Los resultados obtenidos permitieron constatar una reducción del espesor corneal con el envejecimiento, que es más marcada en las mujeres que en los hombres. En cuanto a la curvatura corneal, no mostró diferencias consistentes con la edad, ni fue sensiblemente diferente entre hombres y mujeres; ricamente, se aprecia que las mujeres menores de 50 años, examinadas en el 5º día del ciclo, presentas córneas ligeramente más curvas que el conjunto de la muestra, y también se observa que predomina el astigmatismo directo que con la edad evoluciona hacia un patrón inverso. Como resultado más evidente en los pacientes con queratocono cabe destacar que el porte de LC puede influir sobre la progresión de la ectasia. El porte prolongado de lentes de contacto de hidrogel de silicona no modifica el espesor en ninguna zona de la córnea, ni la curvatura corneal central. Sin embargo, produce un ligero aplanamiento en la periferia y medioperiferia. Finalmente, reseñar que el láser excimer Schwind es un instrumento muy fiable en cuanto a la corrección del defecto refractivo, pero su computador emite un informe de ablación que debe ser tomado con reservas en cuanto a la magnitud de la ablación.
O conhecimento das características morfométricas, biomecânicas e fisiológicas da córnea é fundamental para o estudo das alterações nela produzidas pela idade, sexo, assim como para o seguimento de processos tais como a adaptação de lentes de contacto ou a resposta aos materiais e geometrias das referidas lentes. Sendo também importante para o estudo de determinadas patologias como o queratocone e a para a correcção de ametropias mediante cirurgia refractiva, que constituem os objectivos deste trabalho. Com o objectivo de obter os conhecimentos atrás descritos este estudo analisa a espessura e a curvatura da córnea em amostras populacionais mais adequadas para cada finalidade, sendo para isso utilizado fundamentalmente a biometria ultra-sónica, o sistema de análise corneal Orbscan II® e o videoqueratoscopio EyeSys®. Os resultados obtidos permitiram constatar a existência de uma redução da espessura corneal com o envelhecimento sendo mais acentuada nas mulheres que nos homens. Em relação à curvatura corneal, não se verificou diferenças com a idade nem entre a população masculina e feminina, tendo-se verificado apenas que para as mulheres com idades inferiores a 50 anos, examinadas no 5º dia do ciclo menstrual, apresentavam córneas ligeiramente mais curva que o conjunto da amostra. Verificouse ainda uma predominância do astigmatismo directo que com a idade evolui na direcção de um padrão inverso. Como resultado mais relevante nos pacientes de queratocone é necessário destacar que o uso de lentes de contacto pode influenciar na progressão da ectasia. O uso prolongado de lentes de contacto de hidrogel-silicone não altera a espessura da córnea em nenhuma zona, nem a espessura corneal central. No entanto, verificou-se um ligeiro aplanamento nas regiões paracentral e periférica. Finalmente, é importante realçar que o laser excimer de Schwind é um instrumento bastante fiável no que diz respeito à correcção do defeito refractivo, no entanto o relatório de ablação fornecido pelo equipamento deve ser analisado com alguma reserva no que diz respeito à magnitude da ablação.
Silva, Ana Rita Araújo da. "Lentes de contacto e líquidos de manutenção: alterações na humectabilidade." Master's thesis, 2015. http://hdl.handle.net/1822/41146.
Full textO contínuo desenvolvimento das lentes de contacto (LC) originou o aparecimento das lentes de Silicone-Hidrogel (Si-Hi) no final da década de 90. Estas lentes permitiram reduzir os efeitos de hipoxia ocular, mas a hidrofobicidade provocada pela incorporação de monómeros de silicone levou a uma diminuição do conforto. A inclusão de tratamentos de superfície nas lentes e o desenvolvimento de líquidos de limpeza e desinfeção específicos tentaram melhorar a humectabilidade e o conforto. Apesar destas evoluções, o desconforto e reações de hipersensibilidade continuaram a persistir nos utilizadores, sendo mais evidente com determinadas combinações de lentes Si-Hi e líquidos. O objetivo deste trabalho foi avaliar o efeito de diversos líquidos de manutenção em algumas propriedades das LC, como o caso do índice de refração (IR), conteúdo em água (CA) e humectabilidade através da medição dos ângulos de contacto (AC). Neste trabalho foram avaliadas quatro LC de Si-Hi, Air Optix Aqua™ (Lotrafilcon B), Acuvue® Oasys™ (Senofilcon A), Biofinity™ (Comfilcon A) e Purevision® 2 (Balafilcon A) e uma LC de hidrogel convencional Acuvue® 2 (Etafilcon A). Os líquidos de manutenção incluíram três soluções únicas, ReNu MultiPLUS® MPS, Biotrue™ e Optifree® PureMoist® e um sistema de peróxido de hidrogénio AO Sept® Plus. As lentes foram imersas nos líquidos por um período de 12 horas e, posteriormente, foram avaliadas as propriedades das LC. As medidas foram realizadas antes e depois da imersão das lentes nos diferentes líquidos. Dos resultados obtidos, pode-se verificar que o IR e o CA das lentes sofreram alterações significativas após a exposição aos líquidos. Estas alterações dependem da combinação do material da lente e do líquido utilizado. O AC diminuiu em praticamente todas as lentes, quando comparadas com o valor inicial, com os líquidos usados. Este trabalho revela que os líquidos de manutenção induzem alterações nas propriedades das LC, demonstrando a existência de interações entre os materiais das lentes e os líquidos. Estas interações podem ser importantes na prática clínica, pois podem ser determinantes para o conforto do paciente.
The permanent development of the contact lens (LC) allowed the birth of siliconehydrogel lens (Si-Hy) at the end of the 90s. These lenses reduced the effects of ocular hypoxia, but the hydrophobicity caused by the incorporation of silicone monomers led to a decrease in comfort. The inclusion of surface treatments on the lenses and the development of specific lens care solutions aim to improve the wettability and comfort. Despite these developments, discomfort and hypersensitivity reactions continued to persist for users, being more evident in some combinations of silicone-hydrogel lenses and solutions. The aim of this study was to analyze the effect of different lens care systems regarding some LC properties, such as refractive index (IR), water content (CA) wettability with measurements of contact angle (AC). In this study, four silicone-hidrogel contact lenses, Air Optix Aqua™ (Lotrafilcon B), Acuvue® Oasys™ (Senofilcon A), Biofinity™ (Comfilcon A) and Purevision® 2 (Balafilcon A) and one convencional LC, Acuvue® 2 (Etafilcon A) were analyzed. Regarding the lens care systems, three multipurpose desinfecting solutions were used, ReNu MultiPLUS® MPS, Biotrue™ and Optifree® PureMoist® and one hydrogen peroxide system care AO Sept® Plus. Lenses were immersed in each lens care solutions for 12 hours and then LC properties were evaluated. Measures were taken before and after lens immersion in the different lens care systems. From the results obtained in this study, it is possible to conclude that lens refractive index and water content suffered signifficant changes after lens care systems exposure. These changes depend on the lens material and the lens care solution combination. The contact angle decreased in most of the lenses with the lens care system used, when compared to baseline. The study shows that lens solutions induce changes in the contact lenses properties, revealing the existence of interactions between contact lens material and lens care solutions. These interactions may be important in clinical practice, because they can be significant for the patient´s comfort.
Garcia, Vanessa Parente. "Estudo da contaminação em diferentes materiais de lentes de contacto." Master's thesis, 2015. http://hdl.handle.net/10400.6/5965.
Full textThe successful use of contact lenses is often related with the interaction of the lens material with the physiological parameters of the cornea and in particular with the lacrimal structure. In this context, it is a priority that the lens material is biocompatible with the ocular tissues and also resistant to microorganisms and substances present on the tear film and ocular surface. This study consisted in analyzing and characterizing the contaminants in worn and un-worn contact lenses and it was divided in two experiments. The first one consisting in analyzing and characterizing the type of deposits and microorganisms present on contact lenses that have been worn on daily basis for one month, and the second one consisting in evaluate the tendency of the lens material to adsorb two types of protein (lysozyme and albumin), without the influence of the ocular defense mechanisms or the care regimen. The first experiment showed more organic deposits on silicone-hydrogel materials (balafilcon A e lotrafilcon B) and more inorganic deposits on hydrogel materials (omafilcon B). The second experiment only allowed concluding that there was a higher deposition of lisozime on the three contact lens materials. In conclusion, the adsorption of substances and microorganisms is influenced by a lot of factors, so it is difficult to define which are more relevant because it varies between materials.
Paiva, Tatiana Branco de. "Catarata, Excesso de Convergência, Adaptação de Lentes de Contacto Multifocais." Master's thesis, 2016. http://hdl.handle.net/10400.6/6286.
Full textThis probation reports was written based in the clinical praticed in optometry, that took place in Aveiro, in OcularEyeCare, from the 3rd of january to the 30th of june 2014. The pratical training lasted for six months and during that time many clinical cases were analized. Three clinical cases were choosen, one related to na ocular pathology, another on binocular vision anomaly and the last to contact lenses adaptation. The following subjects were selected: Cataracts, Convergence Excess and Multifocal contact lenses adaptation.
Mendes, Sonia Filipa Xavier. "Libertação controlada de fármaco em lentes de contacto." Master's thesis, 2015. http://hdl.handle.net/10316/40252.
Full textEste trabalho teve como principal objetivo o desenvolvimento e aprimoramento da técnica de impregnação/deposição de fármaco em lentes de contacto utilizando dióxido de carbono supercrítico (scCO2), com o intuito de estudar uma alternativa viável e mais eficiente que as formas farmacêuticas para administração ocular já existentes no mercado. Com este propósito pretende-se a obtenção e caracterização de lentes de libertação farmacológica com perfis de libertação controlada e localizada para o tratamento de patologias oculares. O estudo do efeito de diferentes condições de pressão e temperatura no processo de impregnação para avaliar a sua eficiência tem em conta dois pontos cruciais: a quantidade de fármaco impregnado em cada lente e a ausência de alterações significativas nas propriedades físicas e químicas das lentes de contacto. Os fármacos utilizados ao longo destes meses de trabalho laboratorial foram o Ácido all-trans-Retinóico (ATRA) para o tratamento da síndrome do olho seco e da doença macular degenerativa (DMRI) e a Norfloxacina (NFLX) para o tratamento de infeções oculares. Como matriz polimérica foram utilizadas lentes de contacto comerciais: a Balafilcon A e a Hilafilcon B, que constituem o veículo para o fármaco e conferem a estrutura do sistema de libertação controlada. O primeiro sistema estudado foi o ATRA impregnado na Balafilcon A, verificando que se conseguiu impregnar uma quantidade de fármaco que varia entre os 329 e 900 μg em cada lente, dependendo das condições que foram utilizadas. A condição que permitiu impregnar maior quantidade de fármaco foi a de 200 bar à temperatura de 55ºC. Os perfis de libertação in vitro do fármaco foram traçados com base num período de 6 dias e demonstraram que mais de 94 % do fármaco foi libertado nas primeiras 24 horas do ensaio. Relativamente à NFLX impregnada na Balafilcon A, concluiu-se que foi possível impregnar cerca de 38 a 170 μg de fármaco em cada lente, tendo-se igualmente verificado que o máximo de impregnação foi para a condição de 200 bar a 55ºC. O perfil de libertação obtido durante 8 horas revelou que ao fim de 6 horas de libertação o fármaco presente na matriz já se tinha libertado na totalidade. O sistema que permitiu alcançar o melhor perfil de libertação controlada foi o do ATRA impregnado na Balafilcon A, uma vez que a libertação do fármaco decorreu ao longo de um período mais elevado quando comparado com os outros sistemas. Além dos ensaios de libertação in vitro, foram realizados estudos de caracterização físico- química e morfológica das lentes de contacto impregnadas recorrendo: à análise de espectroscopia de infravermelho por transformada de Fourier (FTIR), para verificar a presença do fármaco na superfície do polímero; à avaliação dos ângulos de contacto e da transmitância onde se confirmou que o processo de impregnação/deposição usando scCO2 não provocou alterações significativas nas propriedades das lentes; e à microscopia eletrónica de varrimento (SEM) onde foi possível afirmar a presença e localização dos fármacos na superfície e no interior da matriz polimérica. Os resultados obtidos indicam que as lentes de contacto têm um enorme potencial para serem utilizadas enquanto sistemas de libertação farmacológica controlada, em específico na superfície ocular. O trabalho desenvolvido permite a obtenção de conclusões significativas que poderão ser utilizadas como bases sólidas para a continuação do trabalho no sentido de aprimorar o desenvolvimento dos sistemas de libertação propostos recorrendo a esta técnica de impregnação por recurso ao scCO2.