To see the other types of publications on this topic, follow the link: Limit detekcie.

Journal articles on the topic 'Limit detekcie'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 journal articles for your research on the topic 'Limit detekcie.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse journal articles on a wide variety of disciplines and organise your bibliography correctly.

1

Dolaria, Nanik, and Helena Manik. "UJI VALIDASI pada Analisis Formalin Menggunakan Spektrofotometer UV-Vis." Buletin Teknik Litkayasa Akuakultur 6, no. 1 (January 6, 2017): 61. http://dx.doi.org/10.15578/blta.6.1.2007.61-67.

Full text
Abstract:
Uji ini bertujuan untuk mengetahui reabilitas dan limit deteksi analisis kuantitatif formalin pada spektrofotometer UV-VIS menggunakan pereaksi Nash. Hasil uji menunjukkan bahwa grafik standar formalin pada konsentrasi 0,75; 1,5; 3; 6,25; dan 12,5 mg/L membentuk garis regresi linear yang baik dengan nilai R2 0,9943. Berdasarkan hal tersebut, analisis limit deteksi yang didasarkan pada rumusan validasi menunjukkan bahwa limit deteksi kuantifikasi instrumentasi spektrofotometer UV-VIS pada analisis kuantitatif formalin adalah sebesar 1,041 mg/L, sedangkan limit deteksi kuantifikasi yang didasarkan pada metode pereaksi Nash adalah sebesar 1,634 mg/L. Berdasarkan batas standar deviasi relatif (RSD) pada proses validasi sistem instrumentasi sebesar 2%, maka limit deteksi kuantifikasi spektrofotometer UV-VIS pada analisis formalin adalah sebesar 0,429 mg/L. Dari hasil tersebut direkomendasikan limit deteksi analisis kuantitatif formalin menggunakan metode pereaksi Nash pada spektrofotometer UV-VIS didasarkan pada batas standar % RSD sebesar 0,429 mg/L.
APA, Harvard, Vancouver, ISO, and other styles
2

Kurnia, Asep, Eman Sulaeman, and Asep Nugraha Ardiwinata. "Verifikasi Alat Multimeter Digital untuk Deteksi Cepat Residu Insektisida dalam Sayuran." Agrikultura 29, no. 3 (July 23, 2019): 124. http://dx.doi.org/10.24198/agrikultura.v29i3.22725.

Full text
Abstract:
ABSTRACTVerification of digital multimeter for rapid detection of insecticide residues on vegetablesThe instruments that usually used for detection of pesticide residues are Gas Chromatography (GC), High Performance Liquid Chromatography (HPLC), and Thin Layer Chromatography (TLC), however, these instruments are expensive, take time, and need a large number of chemicals. Therefore, it is needed to develop rapid method in analyzing pesticide residues. One instrument that is potential for rapid detection of pesticide residues is digital multimeter. This method uses resistance differences of electrical current on chemical compounds. The aim of this research was to assess capability of digital multimeter for rapid detection of insecticide residues on vegetables by the aspects of precision, accuracy, linearity, and detection limit. The research was conducted in IAERI laboratory, Laladon, Bogor on January to December 2012. Insecticide residues that detected were organochlorine and organophosphate on some vegetables of potato, cabbage, carrot, onion, chili, and cucumber. The results showed that precision values of digital multimeter for detection organochlorine and organophosphate residues on vegetables were 0.02 to 2.46%. Linearity values of digital multimeter for detection endrin on onion and potato, heptachlor on onion, BHC on cucumber, chlorphyriphos on potato and cabbage, and dichlorvos on cabbage were 0.81, 0.84, 0.95, 0.71, 0.95, 0.80 and 0.76, respectively. Accuracy values of digital multimeter for detecting endrin and dieldrin on onion, chlorphyriphos on potato and cabbage, and profenophos on chili were 106.93%, 115.08%, 72.89%, 72.40%, and 98.06%, respectively. Detection and quantification limits of digital multimeter for detecting organochlorine were 0.08 to 0.17 ppm and 0.27 to 0.56 ppm, respectively. Meanwhile, detection and quantification limits of digital multimeter for detecting organophosphate were 0.05 to 0.27 ppm and 0.16 to 0.90 ppm, respectively. This result showed that digital multimeter was accurate and representative instrument for detecting pesticide residues on vegetables.Keywords: Digital Multimeter, Pesticides residue, VegetablesABSTRAKAlat yang digunakan untuk analisis residu pestisida antara lain Kromatografi Gas (KG), Kromatografi Cair Kinerja Tinggi (KCKT), Kromatografi Lapis Tipis (KLT), namun alat tersebut sangat mahal, dan perlu proses cukup lama serta memerlukan bahan kimia yang banyak. Untuk itu perlu dikembangkan metode cepat analisis residu pestisida. Salah satu alternatif deteksi cepat residu pestisida adalah dengan menggunakan Alat Multimeter Digital (AMD). Teknik analisis ini menggunakan prinsip perbedaan resistensi (tahanan) terhadap arus listrik dari senyawa kimia residu pestisida. Percobaan ini bertujuan mengetahui cara kerja awal AMD untuk deteksi cepat residu insektisida pada tanaman sayuran dari aspek presisi, akurasi, linearitas, dan limit deteksi. Penelitian dilaksanakan di Laboratorium Balai Penelitian Lingkungan Pertanian (Balingtan) di Laladon Bogor, mulai bulan Januari hingga Desember 2012. Residu insektisida yang dideteksi adalah organoklorin dan organofosfat pada beberapa sayuran yaitu kentang, kubis, wortel, bawang merah, cabe merah dan mentimun. Hasil penelitian menunjukkan bahwa nilai presisi AMD dalam mendeteksi organoklorin dan organofosfat pada sayuran berkisar 0,02-2,46%. Nilai linearitas AMD dalam mendeteksi endrin pada bawang merah dan kentang, heptaklor pada bawang merah, BHC pada mentimun, klorpirifos pada kentang dan kubis, serta diklorfos pada kubis masing-masing sebesar 0,81, 0,84, 0,95, 0,71, 0,95, 0,80 dan 0,76. Nilai akurasi AMD dalam mendeteksi endrin dan dieldrin pada bawang merah, klorpirifos padakentang dan kubis, serta profenofos pada cabe merah masing-masing sebesar 106,93 %, 115,08%, 72,89 %, 72,40%, dan 98,06%. Nilai LOD (limit deteksi) dan LOQ (limit quantifikasi) AMD terhadap organoklorin berkisar antara 0,08-0,17 ppm dan 0,27-0,56 ppm, sedangkan terhadap golongan organofosfat berkisar antara 0,05-0,27 ppm dan 0,16-0,90 ppm. Hasil penelitian ini menunjukkan bahwa AMD merupakan alat yang cukup akurat dan representatif untuk deteksi cepat residu pestisida pada sayuran.Kata Kunci: Alat Multimeter Digital, Residu pestisida, Sayuran
APA, Harvard, Vancouver, ISO, and other styles
3

Kurnia, Asep, Eman Sulaeman, and Asep Nugraha Ardiwinata. "Verifikasi Alat Multimeter Digital untuk Deteksi Cepat Residu Insektisida dalam Sayuran." Agrikultura 29, no. 3 (December 6, 2018): 124. http://dx.doi.org/10.24198/agrikultura.v29i3.21646.

Full text
Abstract:
ABSTRACTVerification of digital multimeter for rapid detection of insecticide residues on vegetablesThe instruments that usually used for detection of pesticide residues are Gas Chromatography (GC), High Performance Liquid Chromatography (HPLC), and Thin Layer Chromatography (TLC), however, these instruments are expensive, take time, and need a large number of chemicals. Therefore, it is needed to develop rapid method in analyzing pesticide residues. One instrument that is potential for rapid detection of pesticide residues is digital multimeter. This method uses resistance differences of electrical current on chemical compounds. The aim of this research was to assess capability of digital multimeter for rapid detection of insecticide residues on vegetables by the aspects of precision, accuracy, linearity, and detection limit. The research was conducted in IAERI laboratory, Laladon, Bogor on January to December 2012. Insecticide residues that detected were organochlorine and organophosphate on some vegetables of potato, cabbage, carrot, onion, chili, and cucumber. The results showed that precision values of digital multimeter for detection organochlorine and organophosphate residues on vegetables were 0.02 to 2.46%. Linearity values of digital multimeter for detection endrin on onion and potato, heptachlor on onion, BHC on cucumber, chlorphyriphos on potato and cabbage, and dichlorvos on cabbage were 0.81, 0.84, 0.95, 0.71, 0.95, 0.80 and 0.76, respectively. Accuracy values of digital multimeter for detecting endrin and dieldrin on onion, chlorphyriphos on potato and cabbage, and profenophos on chili were 106.93%, 115.08%, 72.89%, 72.40%, and 98.06%, respectively. Detection and quantification limits of digital multimeter for detecting organochlorine were 0.08 to 0.17 ppm and 0.27 to 0.56 ppm, respectively. Meanwhile, detection and quantification limits of digital multimeter for detecting organophosphate were 0.05 to 0.27 ppm and 0.16 to 0.90 ppm, respectively. This result showed that digital multimeter was accurate and representative instrument for detecting pesticide residues on vegetables.Keywords: Digital Multimeter, Pesticides residue, VegetablesABSTRAKAlat yang digunakan untuk analisis residu pestisida antara lain Kromatografi Gas (KG), Kromatografi Cair Kinerja Tinggi (KCKT), Kromatografi Lapis Tipis (KLT), namun alat tersebut sangat mahal, dan perlu proses cukup lama serta memerlukan bahan kimia yang banyak. Untuk itu perlu dikembangkan metode cepat analisis residu pestisida. Salah satu alternatif deteksi cepat residu pestisida adalah dengan menggunakan Alat Multimeter Digital (AMD). Teknik analisis ini menggunakan prinsip perbedaan resistensi (tahanan) terhadap arus listrik dari senyawa kimia residu pestisida. Percobaan ini bertujuan mengetahui cara kerja awal AMD untuk deteksi cepat residu insektisida pada tanaman sayuran dari aspek presisi, akurasi, linearitas, dan limit deteksi. Penelitian dilaksanakan di Laboratorium Balai Penelitian Lingkungan Pertanian (Balingtan) di Laladon Bogor, mulai bulan Januari hingga Desember 2012. Residu insektisida yang dideteksi adalah organoklorin dan organofosfat pada beberapa sayuran yaitu kentang, kubis, wortel, bawang merah, cabe merah dan mentimun. Hasil penelitian menunjukkan bahwa nilai presisi AMD dalam mendeteksi organoklorin dan organofosfat pada sayuran berkisar 0,02-2,46%. Nilai linearitas AMD dalam mendeteksi endrin pada bawang merah dan kentang, heptaklor pada bawang merah, BHC pada mentimun, klorpirifos pada kentang dan kubis, serta diklorfos pada kubis masing-masing sebesar 0,81, 0,84, 0,95, 0,71, 0,95, 0,80 dan 0,76. Nilai akurasi AMD dalam mendeteksi endrin dan dieldrin pada bawang merah, klorpirifos pada kentang dan kubis, serta profenofos pada cabe merah masing-masing sebesar 106,93 %, 115,08%, 72,89 %, 72,40%, dan 98,06%. Nilai LOD (limit deteksi) dan LOQ (limit quantifikasi) AMD terhadap organoklorin berkisar antara 0,08-0,17 ppm dan 0,27-0,56 ppm, sedangkan terhadap golongan organofosfat berkisar antara 0,05-0,27 ppm dan 0,16-0,90 ppm. Hasil penelitian ini menunjukkan bahwa AMD merupakan alat yang cukup akurat dan representatif untuk deteksi cepat residu pestisida pada sayuran.Kata Kunci: Alat Multimeter Digital, Residu pestisida, Sayuran
APA, Harvard, Vancouver, ISO, and other styles
4

Čupić, Nedeljka. "FUNKCIONALNOSTI LIMITA U GEOSENZORSKIM MREŽAMA." Zbornik radova Fakulteta tehničkih nauka u Novom Sadu 35, no. 02 (January 29, 2020): 356–59. http://dx.doi.org/10.24867/06kg01cupic.

Full text
Abstract:
U radu je opisana primjena perma­nentnog monitoringa u okviru geosenzorskih mreža. Objašnjen je postupak realizacije geosenzorske mreže kao i podešavanja parametara pri detekciji alarma u procesu praćenja deformacija objekata. Eksperimentalni dio rada odnosi se na mjerenja pomoću geodetskih i geotehničkih senzora sa ciljem ispitivanja alarmnog sistema u softveru Leica GeoMos.
APA, Harvard, Vancouver, ISO, and other styles
5

Riskyna, Alni, Bambang Kuswandi, and Indah Purnama Sary. "Pengembangan Strip Tes Berbasis Pararosanilina untuk Deteksi Formalin pada Sampel Tahu." Pustaka Kesehatan 6, no. 3 (September 1, 2018): 416. http://dx.doi.org/10.19184/pk.v6i3.9869.

Full text
Abstract:
Test strip based on pararosaniline has been developed for formaldehyde detection in tofu samples. The test strip as a formaldehyde sensors has been fabricated by immobilizing pararosaniline on whatman filter paper. The test strip was characterized for liniearity, detection limit, quantitation limit, selectivity, accuracy and precision. It has response time at 4 minutes and good liniearity was achieved in the concentration range of 2-80 ppm with correlation coefficient of (r) 0.999. The detection limit and quantitation limit were 0.048 ppm and 0.161 ppm, respectively. The RSD of reproducibility was found 8.04%, where recovery was 80-110%. The life time of the test strip was 14 days when it was stored at 40C. The test strip has been successfully applied to detect formaldehyde in tofu samples. The result also shown in agreement with spectrophotometry uv-vis method. Keywords: formalin, pararosaniline, tofu, immobilization, strip test
APA, Harvard, Vancouver, ISO, and other styles
6

Nurjanah, Lusi Ike, Tri Mulyono, and A. Asnawati. "Analisis Sistem Alir Menggunakan Dua Detektor untuk Mendeteksi Besi(II) (Fe2+) dan Nitrat (NO3-) Secara Simultan." BERKALA SAINSTEK 6, no. 2 (December 10, 2018): 55. http://dx.doi.org/10.19184/bst.v6i2.9198.

Full text
Abstract:
Artikel ini melaporkan tentang analisis besi(II) dan nitrat secara simultan dengan Flow Injection Analysis (FIA). Metode ini menggunakan dua detektor yang dihubungkan dengan satu komputer. Flow Injection Analysis dirangkai dengan menghubungkan Three-Way Solenoid Valve, pompa peristaltik, detektor spektrofotometri dan potensiometri serta komputer. Sinyal FIA spektrofotometri didasarkan pada reaksi pembentukan senyawa komplek antara besi(II) dengan reagen 1.10-fenantrolin. Sinyal FIA potensiometri didasarkan pada keberadaan nitrat yang diperkuat dengan larutan ISA 2M ((NH4)2SO4). Salah satu parameter yang mempengaruhi metode ini yaitu volume reagen. Kinerja sistem injeksi alir didasarkan pada linieritas, limit deteksi, sensitivitas, keterulangan dan uji recovery. Hasil penelitian menunjukkan bahwa volume reagen yang optimum pada penentuan besi(II) dan nitrat yaitu 0,20 mL. Persamaan kurva kalibrasi yang diperoleh dari analisis besi(II) yaitu menunjukkan nilai linieritas sebesar 0.997, sensitivitas sebesar 0.123, limit deteksi sebesar 0.016 ppm dan nilai ketelitian terendah 99.20% serta uji recovery sebesar 98.00%. Persamaan kurva kalibrasi yang diperoleh dari analisis nitrat yaitu menunjukkan nilai linieritas sebesar 0.999, sensitivitas sebesar -96.77 mV per dekade, limit deteksi sebesar 0.36 ppm dan nilai ketelitian terendah sebesar 98.22% serta uji recovery sebesar 96.00%. Kata Kunci: Besi(II), nitrat, penentuan simultan, FIA, spektrofotometri, potentsiometri.
APA, Harvard, Vancouver, ISO, and other styles
7

Sunardi, Setyani Hardiani, and Aris Mukimin. "PENGEMBANGAN METODE ANALISIS PARAMETER MINYAK DAN LEMAK PADA CONTOH UJI AIR." Jurnal Riset Teknologi Pencegahan Pencemaran Industri 5, no. 1 (May 31, 2014): 1–6. http://dx.doi.org/10.21771/jrtppi.2014.v5.no1.p1-6.

Full text
Abstract:
Minyak dan lemak merupakan parameter yang konsentrasi maksimumnya dipersyaratkan untuk air limbah industri dan air permukaan. Analisis infra merah dan gravimetri adalah dua metode standar yang hingga saat ini digunakan. Kelemahan metode-metode tersebut yaitu penggunaan pelarut CCl4(metode IR) dan daerah konsentrasi analisis yang besar (metode gravimetri) sehingga penting dilakukan penelitian penggunaan pelarut lain dan penurunan limit deteksi, khususnya metode gravimetri. Pelarut C2Cl4 dan S316 digunakan sebagai pelarut ekstraksi pada metode IR karena tergolong pelarut yang masih direkomendasikan untuk penggunaannya. Variasi volume sampel dan tahapan ekstraksi dengan n-heksan sebagai pelarut dilakukan untuk pengembangan metode gravimetri sehingga mampu menurunkan limit deteksi di bawah 10 mg/L. Jenis minyak yang digunakan sebagai sampel yaitu minyak nabati dan minyak mineral. Pada pembacaan absorbansi pelarut C2Cl4 dan S316 menunjukkan level respon yang sangat tinggi yaitu 18 mg/L (C2Cl4) dan 15 mg/L (S316) sehingga tidak bisa digunakan untuk analisis minyak dengan metode infra merah. Pada metode gravimetri diperoleh persen recovery 92,28% (sampel minyak nabati) dan 99,25% (sampel minyak mineral) dengan konsentrasi analit sebesar 0,9 mg/L dan 0,88 mg/L. Nilai persen recovery tersebut diperoleh pada volume sampel 2000 mL dan teknik ekstraksi 4 tahap dengan limit deteksi 0,5639 mg/L dan 0,4736 mg/L sehingga pengembangan metode gravimetri ini layak digunakan untuk analisis sampel air limbah dan air permukaan.
APA, Harvard, Vancouver, ISO, and other styles
8

Astuti, Widy, and Abdurahman Fauzi. "Perancangan Deteksi Banjir Menggunakan Sensor Kapastif Mikrokontroler ATMega328p dan SMS Gateway." Jurnal Informatika 5, no. 2 (September 15, 2018): 255–61. http://dx.doi.org/10.31311/ji.v5i2.3868.

Full text
Abstract:
AbstrakPermasalahan yang sering terjadi pada lingkungan masyarakat adalah kesulitan untuk mendeteksi mengenai akan datangnya banjir secara dini, sehingga berdampak pada kerugian materil dan korban jiwa. Untuk itu diperlukan suatu sistem yang dapat mendeteksi banjir secara dini agar masyarakat dapat langsung mengetahui informasi peringatan yang cepat dan efektif sehingga dapat melakukan antisipasi dini dengan penyelamatan diri atau barang yang berharga.Dengan menggunakan sensor kapasitif yang terbuat dari dua buah lempeng PCB yang diberi batas-batas tertentu untuk mengukur ketinggian air sungai serta dilengkapi teknologi SMS Gateway menggunakan Modul SIM 800L yang memungkinkan sistem dapat mengirimkan informasi peringatan banjir secara dini langsung ke handphone melalui SMS. Rancang bangun alat deteksi banjir ini dibuat sedemikian rupa dengan melakukan percobaan yaitu membuat suatu prototipe dengan tabung air yang telah diterapkan sensor kapasitif berbasis mikrokontroler yang didalamnya terdapat sebuah program Bahasa C yang sudah di compile. Mikrokontroler ATMega328p akan membaca sensor kapasitif berdasarkan nilai kapasitansi air. Data tersebut akan diproses oleh mikrokontroler ATMega328p dan melakukan perintah output melalui LCD, LED, dan buzzer untuk menampilkan status dari ketinggian permukaan air sungai.Dari prototipe sebuah tabung air yang diterapkan sensor kapasitif sebagai sensor deteksi banjir berbasis mikrokontroler dan SMS Gateway telah berhasil dibuat dan dapat berjalan dengan baik sesuai dengan yang diharapkan. Ketika air mencapai batas aman maka lampu LED hijau menyala, pada batas siaga maka LED kuning menyala dan mengirimkan sms peringatan, serta pada batas bahaya maka LED merah menyala dan mengirim sms juga buzzer menyala. Kata Kunci: Alat Deteksi Banjir, Mikrokontroler, SMS Gateway AbstractProblems that often occur in the community are difficult to detect about the arrival of flooding early, so that it has an impact on material loss and loss of life. For this reason, a system that can detect flooding early is needed so that people can immediately find out information about warnings that are fast and effective so they can do early anticipation by rescuing themselves or valuable items. By using a capacitive sensor made of two PCB plates that are bounded certain limits for measuring river water level and equipped with SMS Gateway technology using the 800L SIM Module that allows the system to send flood warning information early directly to the handphone via SMS, the design of this flood detection device is made in such a way as to do an experiment that is to make a prototype with a tube water that has been applied is a microcontroller-based capacitive sensor in which there is a C language program that has been compiled. ATMega328p microcontroller will read capacitive sensors based on the value of water capacitance. The data will be processed by the ATMega328p microcontroller and perform output commands via LCD, LED, and buzzer to display the status of the river water level. goes well as expected. When the water reaches the safe limit, the green LED lights on, at the standby limit, the yellow LED lights up and sends an SMS alert, and at the danger limit, the red LED lights up and sends an SMS also the buzzer lights up. Keywords: Flood Detection Tool, Microcontroller, SMS Gateway.
APA, Harvard, Vancouver, ISO, and other styles
9

Astuti, Widy, and Abdurahman Fauzi. "Perancangan Deteksi Banjir Menggunakan Sensor Kapastif Mikrokontroler ATMega328p dan SMS Gateway." Jurnal Informatika 5, no. 2 (September 15, 2018): 255–61. http://dx.doi.org/10.31294/ji.v5i2.3868.

Full text
Abstract:
AbstrakPermasalahan yang sering terjadi pada lingkungan masyarakat adalah kesulitan untuk mendeteksi mengenai akan datangnya banjir secara dini, sehingga berdampak pada kerugian materil dan korban jiwa. Untuk itu diperlukan suatu sistem yang dapat mendeteksi banjir secara dini agar masyarakat dapat langsung mengetahui informasi peringatan yang cepat dan efektif sehingga dapat melakukan antisipasi dini dengan penyelamatan diri atau barang yang berharga.Dengan menggunakan sensor kapasitif yang terbuat dari dua buah lempeng PCB yang diberi batas-batas tertentu untuk mengukur ketinggian air sungai serta dilengkapi teknologi SMS Gateway menggunakan Modul SIM 800L yang memungkinkan sistem dapat mengirimkan informasi peringatan banjir secara dini langsung ke handphone melalui SMS. Rancang bangun alat deteksi banjir ini dibuat sedemikian rupa dengan melakukan percobaan yaitu membuat suatu prototipe dengan tabung air yang telah diterapkan sensor kapasitif berbasis mikrokontroler yang didalamnya terdapat sebuah program Bahasa C yang sudah di compile. Mikrokontroler ATMega328p akan membaca sensor kapasitif berdasarkan nilai kapasitansi air. Data tersebut akan diproses oleh mikrokontroler ATMega328p dan melakukan perintah output melalui LCD, LED, dan buzzer untuk menampilkan status dari ketinggian permukaan air sungai.Dari prototipe sebuah tabung air yang diterapkan sensor kapasitif sebagai sensor deteksi banjir berbasis mikrokontroler dan SMS Gateway telah berhasil dibuat dan dapat berjalan dengan baik sesuai dengan yang diharapkan. Ketika air mencapai batas aman maka lampu LED hijau menyala, pada batas siaga maka LED kuning menyala dan mengirimkan sms peringatan, serta pada batas bahaya maka LED merah menyala dan mengirim sms juga buzzer menyala. Kata Kunci: Alat Deteksi Banjir, Mikrokontroler, SMS Gateway AbstractProblems that often occur in the community are difficult to detect about the arrival of flooding early, so that it has an impact on material loss and loss of life. For this reason, a system that can detect flooding early is needed so that people can immediately find out information about warnings that are fast and effective so they can do early anticipation by rescuing themselves or valuable items. By using a capacitive sensor made of two PCB plates that are bounded certain limits for measuring river water level and equipped with SMS Gateway technology using the 800L SIM Module that allows the system to send flood warning information early directly to the handphone via SMS, the design of this flood detection device is made in such a way as to do an experiment that is to make a prototype with a tube water that has been applied is a microcontroller-based capacitive sensor in which there is a C language program that has been compiled. ATMega328p microcontroller will read capacitive sensors based on the value of water capacitance. The data will be processed by the ATMega328p microcontroller and perform output commands via LCD, LED, and buzzer to display the status of the river water level. goes well as expected. When the water reaches the safe limit, the green LED lights on, at the standby limit, the yellow LED lights up and sends an SMS alert, and at the danger limit, the red LED lights up and sends an SMS also the buzzer lights up. Keywords: Flood Detection Tool, Microcontroller, SMS Gateway.
APA, Harvard, Vancouver, ISO, and other styles
10

Afifah, Zulfa, Kurniyawan Kurniyawan, and Thorikul Huda. "Verifikasi Metode Penentuan Kadar Timbal (Pb) pada Sampel Udara Ambien Menggunakan Inductifely Coupled Plasma-Optical Emission Spectroscopy (ICP-OES)." IJCA (Indonesian Journal of Chemical Analysis) 2, no. 2 (September 23, 2019): 74–79. http://dx.doi.org/10.20885/ijca.vol2.iss2.art5.

Full text
Abstract:
Telah dilakukan analisa uji logam timbal (Pb) pada udara ambien yang mengacu pada SNI 7119-4:2017 menggunakan Inductifely Coupled Plasma-Optical Emission Spectroscopy (ICP-OES). Verifikasi metode ini untuk mengetahui nilai linieritas, presisi, akurasi, dan limit deteksi, serta mengetahui kadar timbal (Pb) dalam udara ambien. Hasil pengujian kadar logam timbal (Pb) diperoleh hasil yaitu 0,1840 µg/Nm3. Hasil tersebut menunjukkan bahwa udara ambien aman untuk lingkungan, karena dibawah ambang batas yang ditetapkan Peraturan Pemerintah Republik Indonesia No. 41 Tahun 1999. Verifikasi metode udara ambien diperoleh hasil yang baik dengan linieritas 0,999; presisi low range 2,71% dan high range 7,32%; akurasi yang tinggi berdasarkan nilai %trueness low range 100,74% dan high range 104,95% serta limit deteksi IDL, MDL, dan LoQ yaitu 0,0001 µg/Nm3; 0,0012 µg/Nm3; dan 0,0042 µg/Nm3.
APA, Harvard, Vancouver, ISO, and other styles
11

Yanti, Ika. "Verifikasi Metode Analisis TBC (p-tert butylcatechol) pada Air Limbah Industri dari Proses Polimerisasi." INDONESIAN JOURNAL OF CHEMICAL RESEARCH 4, no. 1 (July 10, 2019): 9–13. http://dx.doi.org/10.20885/ijcr.vol4.iss1.art2.

Full text
Abstract:
Verifikasi metode analisis TBC (P-Tert Butylcatechol) dalam air limbah menggunakan Spektrofotometer UV-Vis dengan acuan ASTM D 1157-59 telah dilakukan. Verifikasi metode dilakukan untuk membuktikan bahwa metode yang digunakan dapat dipercaya dan dapat dipertanggungjawabakan. Parameter dari verifikasi metode berupa linieritas, presisi, akurasi, dan limit deteksi. Hasil verifikasi metode TBC dalam air limbah industri telah memenuhi syarat dengan hasil uji linieritas sebesar 0,99999~1, uji akurasi standar 10 ppm; 15 ppm; dan 20 ppm sebesar 104,34%; 101,36%; 98,16%, hasil presisi standar 10 ppm; 15 ppm; dan 20 ppm sebesar 0,12903; 0,08430; 0,08429, uji limit deteksi sebesar 0,09447, dan pemantauan konsentrasi sampel air limbah masih berada di bawah ambang batas dengan rata-rata konsentrasi sampel IH-7004 sebesar 3,23 ppm dan sampel S-8503 sebesar 2,28 ppm hasilnya menunjukkan sudah berada di bawah nilai ambang batas yang telah ditentukan yaitu 16 ppm.
APA, Harvard, Vancouver, ISO, and other styles
12

Irdhawati, Irdhawati, Vivi Eka Indrayani, and Emmy Sahara. "Teknik Voltammetri Pelucutan Anodik Menggunakan Elektroda Glassi Karbon dalam Penentuan Kadar Logam Fe dalam Terong Ungu." Jurnal Kimia Riset 4, no. 2 (December 31, 2019): 111. http://dx.doi.org/10.20473/jkr.v4i2.15897.

Full text
Abstract:
Terong ungu adalah salah satu jenis tanaman yang banyak dibudidayakan. Tingginya permintaan terong menyebabkan petani menggunakan pupuk dan pestisida dari bahan kimia untuk meningkatkan produksi. Penggunaan bahan kimia yang berlebihan dapat mencemari lingkungan. Dalam penelitian ini kadar logam Fe dalam terong ungu ditentukan dengan teknik voltammetry pelucutan anodic. Elektroda kerja yang digunakan adalah glassi karbon, Ag/AgCl sebagai elektroda pembanding, dan kawat platina sebagai elektroda lawan. Parameter pengukuran yang dioptimasi meliputi waktu deposisi, potensial deposisi, dan laju pindai. Selanjutnya dilakukan validasi rentang konsentrasi linier, limit deteksi, limit kuantisasi, keberulangan, dan perolehan kembali. Hasil yang diperoleh yaitu waktu deposisi optimum selama 40 detik, potensial deposisi optimum pada -0,27 V, serta laju pindai 2,5 mV/s. Linieritas larutan standar Fe berada pada rentang 5 sampai 100 mg/L, dengan koefisien korelasi 0,9964. Limit deteksi dan limit kuantisasi berturut-turut 18,36 mg/L dan 37,79 mg/L. Keberulangan pengukuran menghasilkan nilai rasio Horwitz yang lebih kecil dari dua. Perolehan kembali standar logam Fe yang ditambahkan ke dalam larutan sampel diperoleh 100,00 ± 0,07%. Kadar Fe dalam terong ungu pada kondisi pengukuran optimum diperoleh 80,40 ± 1,85 mg/kg. Nilai tersebut lebih kecil dari Standar Nasional Indonesia (SNI) untuk kadar logam dalam bahan pangan yaitu 5000 mg/kg.
APA, Harvard, Vancouver, ISO, and other styles
13

Puji Lestari, Retno, Ricky Nelson, Resi Gifrianto, and Bambang Hindratmo. "Pengujian Sulfur Oksida (SOx) dari Emisi Sumber Tidak Bergerak Menggunakan Metode Ion Kromatografi." Jurnal Ecolab 14, no. 2 (November 1, 2020): 101–10. http://dx.doi.org/10.20886/jklh.2020.14.2.101-110.

Full text
Abstract:
Emisi gas buang oksida-oksida sulfur yang terdiri dari SO2 dan SO3 merupakan salah satu polutan yang menyebabkan terjadinya pencemaran udara. Sumber SOx umumnya berasal dari kegiatan emisi sumber tidak bergerak seperti pembangkit listrik, cerobong industri, pembakaran sumber domestik, maupun insinerator. Pengujian konsentrasi gas oksida-oksida sulfur (SOx) dari emisi sumber tidak bergerak dilakukan sebagai salah satu kegiatan pengkajian metode di Puslitbang Kualitas dan Laboratorium Lingkungan (P3KLL) yang berlangsung pada September – Oktober 2018. Laboratorium P3KLL melakukan verifikasi dengan menentukan limit deteksi terhadap metode uji yang diadopsi dari JIS K 0103:2011 Methods for determination of sulfur oxides in flue gas - Annex JC (normative). Instrumen kromatografi ion (IC) DIONEX ICS5000 tersebut dilengkapi dengan detektor konduktivitas, memiliki ukuran loop sampel 50μL, kolom separator IonPac AS18, kolom penjaga IonPAc AG18 dan suppressor ASRS-II yang dioperasikan pada suhu 35°C. Larutan yang digunakan sebagai eluen adalah campuran 2,7 mM Na2CO3 dan 0,3 mM NaHCO3 pada laju alir 1 L/menit. Tahapan kegiatan terdiri dari pengambilan contoh uji dari fasilitas cerobong genset dan proses verifikasi metode melalui analisis menggunakan IC. Hasil verifikasi metode pengujian SOx dalam emisi gas buang sumber tidak bergerak fasilitas genset menggunakan kromatografi ion menunjukkan bahwa limit deteksi, LoD(G) dan limit kuantifikasi, LoQ(G) yang diperoleh masing-masing sebesar 4 mg/Nm3 dan 13 mg/Nm3, sedangkan limit linearitas, LoL sebesar 834 mg/Nm3. Metode ini telah terverifikasi sesuai persyaratan teknis, dan laboratorium mampu menerapkan metode pengujian tersebut.
APA, Harvard, Vancouver, ISO, and other styles
14

Puji Lestari, Retno, Resi Gifrianto Gifrianto, and Anwar Hadi Hadi. "PENENTUAN LIMIT DETEKSI PENGUJIAN GAS HIDROGEN KLORIDA (HCl) DARI EMISI SUMBER TIDAK BERGERAK MENGGUNAKAN KROMATOGRAFI ION." Jurnal Ecolab 11, no. 1 (January 3, 2017): 32–41. http://dx.doi.org/10.20886/jklh.2017.11.1.32-41.

Full text
APA, Harvard, Vancouver, ISO, and other styles
15

Manoppo, Triska, Sri Sudewi, and Defny S. Wewengkang. "ANALISIS PEMANIS NATRIUM SIKLAMAT PADA MINUMAN JAJANAN YANG DIJUAL DI DAERAH SEKITAR KAMPUS UNIVERSITAS SAM RATULANGI MANADO." PHARMACON 8, no. 2 (May 28, 2019): 488. http://dx.doi.org/10.35799/pha.8.2019.29318.

Full text
Abstract:
ABSTRACT Snack beverages like ice cendol, young coconut ice and mixed ice are snacks that are in great demand by students in the campus area. The sweet taste makes it an example of a product that uses artificial sweetener. Sodium cyclamate is an artificial sweetener whose use is permissible, but may not exceed the limits of its use. This study aims to determine the presence of sodium cyclamate and its level in snack food sold in the Sam Ratulangi University campus area of Manado. The identification of sodium cyclamate was carried out using the TLC method by comparing the Rf value from the standard and the sample. Method validation was done by using parameters such as linearity, detection limits and quantitation, accuracy, and precision limits. The linear relationship between concentration and absorbance was indicated by the equation of ; y = 0.0029x – 1.9155 with a value of r2 = 0.9989 so that the correlation between absorbance and the concentration of cyclamate standard could be very strong. The detection limit obtained 3.724 ppm and the quantity limit was 12.414 ppm. Accuracy test is stated with percent recovery of 102.659%. Precision values are expressed with RSD of 1.1% and 2.0% which means good precision. The results showed that the quantitative analysis of sodium cyclamate content in the sample was not detected while in the quantitative analysis the samples were detected to contain sodium cyclamate but below the maximum level of use that is 1 g/Kg food and beverage ingredients so it was save for consumption. Keywords: Snacks, Sodium Cyclamate, Thin Layer Chromatography, Spectrophotometry UV-Vis, Manado. ABSTRAK Minuman jajanan seperti es cendol, es kelapa muda dan es campur merupakan minuman jajanan yang banyak diminati mahasiswa di daerah kampus. Rasanya yang manis menjadikannya salah satu contoh produk yang menggunakan pemanis buatan. Natrium siklamat adalah pemanis buatan yang penggunaannya dibolehkan, namun tidak boleh melebihi batas penggunaannya. Penelitian ini bertujuan untuk mengetahui keberadaan natrium siklamat dan kadar natrium siklamat dalam minuman jajanan yang dijual di daerah kampus Universitas Sam Ratulangi Manado. Identifikasi natrium siklamat dilakukan dengan menggunakan metode KLT dengan mebandingkan harga Rf dari baku dan sampel. Validasi metode dilakukan dengan menggunakan parameter-parameter seperti linearitas, batas deteksi dan batas kuantitasi, akurasi, dan presisi. Hubungan linier antara konsentrasi dengan absorbansi ditunjukkan dengan persamaan y = 0,0029x – 1,9155 dengan nilai r = 0,9989 sehingga dapat dikatakan korelasi antara absorbansi dan konsentrasi standar siklamat sangat kuat. Batas deteksi yang didapat 3,724 ppm dan batas kuantitas adalah 12,414 ppm. Uji akurasi dinyatakan dengan persen perolehan kembali sebesar 102,659%. Nilai presisi dinyatakan dengan RSD sebesar 1,1% dan 2% yang berarti presisi baik. Hasil penelitian menunjukkan bahwa pada analisis kualitatif kandungan natrium siklamat pada sampel tidak terdeteksi sedangkan pada analisis kuantitatif sampel terdeteksi mengandung natrium siklamat tetapi dibawah kadar maksimum penggunaannya yaitu 1 g/Kg bahan makanan dan minuman sehingga aman untuk dikonsumsi. Kata Kunci : Minuman Jajanan, Natrium Siklamat, Kromatografi Lapis Tipis, Spektrofotometri UV-Vis,Manado.
APA, Harvard, Vancouver, ISO, and other styles
16

Kliwati, Sri. "ALGORITMA DETEKSI FREKUENSI DTMF MENGGUNAKAN KORELASI SILANG UNTUK TELEKOMANDO WAHANA TERBANG." Jurnal Teknologi Dirgantara 14, no. 1 (July 22, 2016): 1. http://dx.doi.org/10.30536/j.jtd.2016.v14.a2562.

Full text
Abstract:
In general, the frequency DTMF detection algorithm using FFT (Fast Fourier Transform) and Goertzel Algorithm. However, in certain circumstances a more suitable signal detected by the other algorithms. For example in a non-periodic signal as the measurement sensors for flight vehicle. The purpose of this study is to develop a system telecommand for flight vehicle. And this paper discusses the frequency DTMF (Dual Tone Multi Frequency) detection method using cross correlation algorithm and data-base DTMF. The simulation results show the frequency detection successfully carried out in accordance with the accuracy of the data-base created (1 Hz) to change the frequency of zero to 1700 Hz (DTMF frequency limit). Abstrak Deteksi frekuensi DTMF secara umum menggunakan algoritma Fast Fourier Transform (FFT) dan Goertzel Algorithm. Akan tetapi pada kondisi tertentu sebuah sinyal lebih cocok dideteksi dengan algoritma yang lain. Misalnya pada sinyal yang non-periodik seperti pada pengukuran sensor-sensor wahana terbang. Tujuan penelitian ini adalah membangun sistem telekomando untuk wahana terbang. Dan tulisan ini membahas metode deteksi frekuensi Dual Tone Multi Frequency (DTMF) dengan menggunakan algoritma korelasi silang dan data-base DTMF. Hasil simulasi menunjukkan deteksi frekuensi berhasil dilakukan sesuai dengan akurasi database yang dibuat (1 Hz) untuk perubahan frekuensi antara nol hingga 1700 Hz (batas frekuensi DTMF).
APA, Harvard, Vancouver, ISO, and other styles
17

Suryadi, Yadi, Ifa Manzila, and Muhammad Machmud. "Potensi Pemanfaatan Perangkat Diagnostik ELISA serta Variannya untuk Deteksi Patogen Tanaman." Jurnal AgroBiogen 5, no. 1 (August 8, 2016): 39. http://dx.doi.org/10.21082/jbio.v5n1.2009.p39-48.

Full text
Abstract:
Diseases are<br />major constrains to agricultural crop productions in Indonesia.<br />In the current free world trade system, the chances of<br />introduction of plant quarantine agents are higher, and are<br />difficult to control, due to importation of seeds and other<br />planting materials. Principles of the plant disease control<br />include exclusion and eradication. Early and accurate disease<br />diagnosis is an early and important step for a successful<br />disease control. Enzyme-linked Immunosorbent Assay<br />(ELISA) is a promising technique for an aneffective and<br />efficient disease diagnosis. Some advantages of technique<br />over the conventional and molecular diagnostic techniques<br />are economical use of reagents, high sensitivity, relatively<br />simple and quick, suitable for large numbers of samples,<br />and adaptable for automation. In the past decade, several<br />variants and kits of ELISA had been introduced, such as<br />Indirect ELISA, F(ab’)2 ELISA, Dot Blot ELISA, and Immuno<br />Fluorescence Assay (ELFA). Based on the solid membrane<br />used, the Dot Blot ELISA some variants were developed,<br />such as the NCM-ELISA, Tissue Blotting ELISA, dan Paper ELISA. The ELISA variants had different limit of detection levels. The limit detection of the variants for bacteria is ranging from 102-105 cells/ml, while those for viruses were from 1-10 ng/ml. The times required for the ELISA tests ranging from 5-48 hours. Models and components of ELISA kits for some viral and bacterial plant pathogens had been developed, but more are still needed since generally for each pathogen needs a different kit. The commercially available ELISA kits are limited in numbers, some of them<br />are for pathogens that are not present in Indonesia. Production of ELISA kits for domestic uses will be more effective and efficent, particularly for pathogens that are present in the country. The ELISA kits are applicable not only fo detection and identification of pathogens, but also for<br />ecological study of the pathogens in conjuction with epidemiological study of the disease. This paper is a brief review on the ELISA technique and its variants and potential uses for detection of plant pathogens
APA, Harvard, Vancouver, ISO, and other styles
18

Azis, Thamrin, Nurhaeni, Caterina Bijang, and A. Nurwahida. "Kinerja Elektroda Platina Terlapis Enzim Butirilkholinesterase-Selulosa Asetat-Glutaraldehida untuk Deteksi Diazinon." KOVALEN: Jurnal Riset Kimia 6, no. 2 (September 1, 2020): 106–11. http://dx.doi.org/10.22487/kovalen.2020.v6.i2.15237.

Full text
Abstract:
Diazinon (o, o-diethyl-o [2-isopropyl-6-methyl pyrimidynyl] phosphorotioate) is one of the organophosphate group pesticides widely used to protect cabbage plants (Brassica olarecea). Pesticide residues left in plants can bind to the cholinesterase enzyme and cause system disruption nerve. Analysis of diazinon residues in cabbage plants needs to be done to determine the level of toxicity caused. The electrochemical biosensor method as an electrochemical sensor uses a working electrode of platinum wire coated with the enzyme butybholchesteresterase (BChE) and cellulose acetate (SA) membrane and glutaraldehyde (GA) can be used for the analysis of pesticide residues. The test results of the SA electrode composition of the 10% GA 20% membrane obtained Nernst factor prices 28.1 µV / decade with a measurement range of 10-9 - 10-6 M, detection limit value of 1.29 x 10-7 M response time of 30 - 300 seconds. Keywords: biosensor, butylochholesterase, membrane, electrochemistry
APA, Harvard, Vancouver, ISO, and other styles
19

Hasanah, Aliya Nur. "Optimasi Kondisi Pemisahan Glibenklamid Kombinasi Metformin dengan KCKT-SPE MIP Akrilamid." Indonesian Journal of Pharmaceutical Science and Technology 3, no. 2 (June 28, 2016): 38. http://dx.doi.org/10.15416/ijpst.v3i2.8527.

Full text
Abstract:
Telah dilakukan dan divalidasi metode analisis glibenklamid dalam plasma menggunakan kromatografi cair kinerja tinggi fase terbalik dengan pretreatment menggunakan SPE C-18 dan SPE-MIP monomer akrilamid. 1 mL metanol dan 1 mL akuabides digunakan sebagai conditioning agent, 1 mL metanol 5% dalam akuabides digunakan sebagai washing agent, dan 1 mL asetonitril digunakan sebagai eluting agent. Hasil ekstraksi dianalisis menggunakan kolom C18 (Shimadzu) 150 x 4,6 mm, ukuran partkel 5 µm, fase gerak 55:45 v/v asetonitril dan triflouro acid 0,1% dengan kecepatan alir 1 mL/menit, deteksi dilakukan pada 227 nm dengan standar internal gliklazid. Metode analisis divalidasi berdasarkan parameter linieritas, presisi, akurasi, selektivitas/spesifisitas, Limit of Detection (LOD), Limit of Quantification (LOQ) dan kesesuaian sistem. Dapat disimpulkan bahwa metode analisis yang digunakan memiliki validitas sesuai dengan yang dipersyaratkan dan SPE-MIP monomer akrilamid memberikan hasil ekstrasi yang lebih optimal dibandingkan dengan SPE C-18.
APA, Harvard, Vancouver, ISO, and other styles
20

Johan, Calvin Wijaya, Sulistyo Emantoko Dwi Putra, and Ernest Suryadjaja. "Deteksi Vibrio harveyi dengan Metode Amplifikasi DNA pada Gen toxR." KELUWIH: Jurnal Sains dan Teknologi 1, no. 1 (February 28, 2020): 29–37. http://dx.doi.org/10.24123/saintek.v1i1.2775.

Full text
Abstract:
Abstrak -Infeksi hewan akuakultur oleh Vibrio harveyi dapat menyebabkan kematian serta kerugian ekonomi. Kemampuan untuk mendeteksi bakteri tersebut secara dini dapat mencegah penyebarannya dalam akuakultur. Penelitian ini bertujuan untuk mengembangkan metode untuk mendeteksi Vibrio harveyi melalui amplifikasi gen toxR. Amplifikasi DNA dilakukan dengan dua metode, yakni amplifikasi isotermal termediasi loop (loop-mediated isothermal amplification, LAMP) dan reaksi berantai polimerase (PCR). Amplifikasi menggunakan metode LAMP menunjukan perlu dilakukan optimasi protokol maupun desain primer untuk mencegah perolehan hasil false positive. Amplifikasi menggunakan metode PCR menghasilkan produk berukuran 229 pasang basa yang spesifik pada Vibrio harveyi dengan batas deteksi hingga 0,526 ng.µL-1 (setara 2,09 × 106 CFU.mL-1). Kata kunci: Akuakultur, LAMP, PCR, toxR, Vibrio harveyi Abstract -Vibrio harveyi infection in aquacultures may cause death and economical loss. Rapid detection of this bacteria may prevent its dispersal in aquacultures. The goal of this research was to develop method in detection of Vibrio harveyi via amplification of toxR gene. DNA amplification was carried out with two methods, loop-mediated isothermal amplification (LAMP) and polymerase chain reaction (PCR). Amplification with LAMP suggest optimization of either protocol or primer design was needed to prevents false positive results. Amplification with PCR yields 229 bp-length product specific to Vibrio harveyi with detection limit up to 0.526 ng.µL-1 (equals to 2.09 × 106 CFU.mL-1). Keywords: Aquaculture, LAMP, PCR, toxR, Vibrio harveyi
APA, Harvard, Vancouver, ISO, and other styles
21

Nur, Arfiani, and Bambang Purwono. "Sintesis Kemosensor Anion Senyawa 4-(2,6-difenil-Piridin-4-Il)-2-Metoksi-Fenol Dari Vanilin." Jurnal Rekayasa Kimia & Lingkungan 12, no. 1 (May 27, 2017): 37. http://dx.doi.org/10.23955/rkl.v12i1.4957.

Full text
Abstract:
Telah dilakukan sintesis kemosensor anion senyawa 4-(2,6-difenil-piridin-4-il)-2-metoksi-fenol (DPMF). Sintesis senyawa target DPMF dilakukan melalui senyawa antara kalkon dengan rendemen reaksi 77%. Uji sebagai sensor anion dilakukan dalam pelarut DMSO-air terhadap anion F-, Cl-, Br-, CN- dan H2PO4-. Senyawa DPMF ini menghasilkan perubahan warna dari tidak berwarna menjadi kuning pada penambahan anion CN-. Analisis spektrofotometer UV-vis pada senyawa DPMF menghasilkan perubahan λmak = 320 nm ke λmak = 370 nm pada penambahan anion CN-. Limit deteksi terhadap anion CN- sebesar 4,11x10-6M. Senyawa ini juga dapat berperan sebagai kemosensor fluoresen dengan sistem “ON-OFF”.
APA, Harvard, Vancouver, ISO, and other styles
22

Ghozali, Muhammad, and Heni Sumarti. "Deteksi Tepi pada Citra Rontgen Penyakit COVID-19 Menggunakan Metode Sobel." Jurnal Imejing Diagnostik (JImeD) 6, no. 2 (July 1, 2020): 51–59. http://dx.doi.org/10.31983/jimed.v6i2.5840.

Full text
Abstract:
Background: Coronavirus Disease 2019 (COVID-19) discovered at the end of 2019 occasioned by coronavirus 2 (SARS-CoV-2) causing severe acute respiratory syndrome and expanded globally so that World Health Organization (WHO) declare a global pandemic. There was a delay of socialization and delivering information to society about this disease. The doctors did a method to detect COVID-19 by reading the correct X-ray images of patients who affected by a coronavirus.Methods: With advances in the field of computers in the application of image processing techniques method of this research use application to get better digital image results for COVID-19 X-ray images, so make it easier to analyze the X-ray images. There are 13 samples of X-ray images that are processed through the clean the stage with high-pass filtering, then segmented with thresholding technique in the lung area, then the edge detection method is used to mark the area that makes the image detail.Results: The result of this detection form the pattern of objects and regions of the spread of coronavirus, then there is a limit on the image looks clear enough, with the Sobel method producing white pixels that are so visible as well.Conclusions: This study to make a simulation of x-ray thorax COVID-19 and know the region of virus infection using Sobel method with thresholding technique that can see the spread of coronavirus and shown that edge detection use Sobel method as one of diagnosing for COVID-19 disease.
APA, Harvard, Vancouver, ISO, and other styles
23

Kliwati, Sri. "ALGORITMA DETEKSI FREKUENSI DTMF MENGGUNAKAN KORELASI SILANG UNTUK TELEKOMANDO WAHANA TERBANG (DTMF FREQUENCY DETECTION ALGORITHM USING CROSSCORRELATION FOR VEHICLE TELECOMMAND)." Jurnal Teknologi Dirgantara 14, no. 1 (March 19, 2018): 1. http://dx.doi.org/10.30536/j.jtd.2016.v14.a2942.

Full text
Abstract:
In general, the frequency DTMF detection algorithm using FFT (Fast Fourier Transform) and Goertzel Algorithm. However, in certain circumstances a more suitable signal detected by the other algorithms. For example in a non-periodic signal as the measurement sensors for flight vehicle. The purpose of this study is to develop a system telecommand for flight vehicle. And this paper discusses the frequency DTMF (Dual Tone Multi Frequency) detection method using cross correlation algorithm and data-base DTMF. The simulation results show the frequency detection successfully carried out in accordance with the accuracy of the data-base created (1 Hz) to change the frequency of zero to 1700 Hz (DTMF frequency limit). ABSTRAKDeteksi frekuensi DTMF secara umum menggunakan algoritma Fast Fourier Transform (FFT) dan Goertzel Algorithm. Akan tetapi pada kondisi tertentu sebuah sinyal lebih cocok dideteksi dengan algoritma yang lain. Misalnya pada sinyal yang non-periodik seperti pada pengukuran sensor-sensor wahana terbang. Tujuan penelitian ini adalah membangun sistem telekomando untuk wahana terbang. Dan tulisan ini membahas metode deteksi frekuensi Dual Tone Multi Frequency (DTMF) dengan menggunakan algoritma korelasi silang dan data-base DTMF. Hasil simulasi menunjukkan deteksi frekuensi berhasil dilakukan sesuai dengan akurasi database yang dibuat (1 Hz) untuk perubahan frekuensi antara nol hingga 1700 Hz (batas frekuensi DTMF).
APA, Harvard, Vancouver, ISO, and other styles
24

Safitri, Rika Endara, Ani Mulyasuryani, Attasith Parnsubsakul, and Patsamon Rijiravanich. "Sensing of Prostate Spesific Antigen by Differential Pulse Anodic Stripping Voltammetry of Gold Nanoparticle - Silver Enhanced Labels." ALCHEMY Jurnal Penelitian Kimia 12, no. 2 (November 2, 2016): 128. http://dx.doi.org/10.20961/alchemy.12.2.1724.128-141.

Full text
Abstract:
<div style="left: 78.8156px; top: 533.372px; font-size: 11.129px; font-family: sans-serif; transform: scaleX(0.968874);" data-canvas-width="302.2885949032258">Metode deteksi Antigen Spesifik Prostat (ASP) berdasarkan pemotongan peptide dengan menggunakan perak enhancer (AgEhn) pada nanopartikel emas (AuNP) sebagai penanda. ASP merupakan serin protease yang dihasilkan secara normal oleh sel jaringan prostat dan sel kanker prostat.ASP secara luas digunakan sebagai biomarker untuk kanker prostat.Aktivitas ASP dideteksi berdasarkan pemotongan peptida yang terikat pada dasar wellplate melalui interaksi biotin – avidin. Setelah proses pemotongan, peptida-SH yang terpotong akan terbuang dalam proses pembilasan, peptidayang terpotong pada dasar wellplate tidak dapat mengikat nanopartikel emas karena kehilangan gugus tiol (-SH) pada ujung peptida. Sisa peptide-SH yang tidak terpotong akan berikatan dengan AuNP, diikuti dengan reduksi secara autokatalitik pada larutan AgEhn menjadi Ag(s). Jumlah Ag yang terdapat pada permukaan AuNP ditentukan secara voltametri lucutan anodik (VLA) setelah mengoksidasi Ag (s) menjadi ion Ag+ menggunakan elektroda screen printed carbon (SPC). Optimasi dilakukan pada kondisi pengukuran dan kondisi immunoassay, sehingga penentuan PSA pada rentang 1–500 ng.mL-1 dihasilkan limit deteksi sebesar 152,204 ng.mL-1 dengan sensitivitas 0,003 μ A/ng.mL-1. Penentuan PSA dengan metode ini telah berhasil dilakukan, namun masih membutuhkan kajian lebih lanjut.</div>
APA, Harvard, Vancouver, ISO, and other styles
25

Safitri, Rika Endara, Ani Mulyasuryani, Attasith Parnsubsakul, and Patsamon Rijiravanich. "Sensing of Prostate Spesific Antigen by Differential Pulse Anodic Stripping Voltammetry of Gold Nanoparticle - Silver Enhanced Labels." ALCHEMY Jurnal Penelitian Kimia 12, no. 2 (November 2, 2016): 128. http://dx.doi.org/10.20961/alchemy.v12i2.1724.

Full text
Abstract:
<div style="left: 78.8156px; top: 533.372px; font-size: 11.129px; font-family: sans-serif; transform: scaleX(0.968874);" data-canvas-width="302.2885949032258">Metode deteksi Antigen Spesifik Prostat (ASP) berdasarkan pemotongan peptide dengan menggunakan perak enhancer (AgEhn) pada nanopartikel emas (AuNP) sebagai penanda. ASP merupakan serin protease yang dihasilkan secara normal oleh sel jaringan prostat dan sel kanker prostat.ASP secara luas digunakan sebagai biomarker untuk kanker prostat.Aktivitas ASP dideteksi berdasarkan pemotongan peptida yang terikat pada dasar wellplate melalui interaksi biotin – avidin. Setelah proses pemotongan, peptida-SH yang terpotong akan terbuang dalam proses pembilasan, peptidayang terpotong pada dasar wellplate tidak dapat mengikat nanopartikel emas karena kehilangan gugus tiol (-SH) pada ujung peptida. Sisa peptide-SH yang tidak terpotong akan berikatan dengan AuNP, diikuti dengan reduksi secara autokatalitik pada larutan AgEhn menjadi Ag(s). Jumlah Ag yang terdapat pada permukaan AuNP ditentukan secara voltametri lucutan anodik (VLA) setelah mengoksidasi Ag (s) menjadi ion Ag+ menggunakan elektroda screen printed carbon (SPC). Optimasi dilakukan pada kondisi pengukuran dan kondisi immunoassay, sehingga penentuan PSA pada rentang 1–500 ng.mL-1 dihasilkan limit deteksi sebesar 152,204 ng.mL-1 dengan sensitivitas 0,003 μ A/ng.mL-1. Penentuan PSA dengan metode ini telah berhasil dilakukan, namun masih membutuhkan kajian lebih lanjut.</div>
APA, Harvard, Vancouver, ISO, and other styles
26

Budi Sungkawa, Hendra, and Anjas Awi Ladika. "Validasi Spektrofotometer UV-VIS pada Analisis Formalin Di Poltekkes Kemenkes Pontianak." Jurnal Laboratorium Khatulistiwa 2, no. 2 (July 7, 2019): 60. http://dx.doi.org/10.30602/jlk.v2i2.332.

Full text
Abstract:
Abstract: Validation is the process of determine a method, an instrument and a technician to fulfl the requirements for testing. Validation of the instrument needs to be done separately. The UV-VIS spectrophotometer in Poltekkes Kemenkes Pontianak has many advantages such as wave length 190 - 1100 nm, using double beam optical system, has 2 nm spectrum bandwidth, but the using of the instrument has not been maximized. It is necessary to validate the UV-VIS spectrophotometer. The aim of this research is to determine the precision, accuracy, linearity, Limit of Detection (LOD) and Limit of Quantifcation (LOQ) on UV-VIS spectrofotometer on formalin analysis at Poltekkes Kemenkes Pontianak. The research uses pre-experimental design and purposive sampling method with formalin standard as population. The sample used is formalin standard with various concentration 0 ppm, 1 ppm, 2 ppm, 3 ppm, 4 ppm and 5 ppm with nine replication. Samples reacted with chromatophore acid, the purple color showed the sample containing formalin, then absorbance value measured to obtain formalin content in the sample. The result of precision value 94.43%, accuracy value 97.77%, linearity test in the concentration range 0-10 ppm gives correlation coeffcient value r = 0.918 with the limit of detection (LOD) of the formalin is 4.98 ppm and the limit of quantifcation (LOQ) of the formalin is 16.60 ppm. Based on the result of the research that it can be concluded that UV-VIS spectrophotometer on formalin analysis in Poltekkes Kemenkes Pontianak well validated because of the fulfllment of fve validation parameter criteria.Abstrak: Validasi adalah proses untuk memastikan apakah suatu metode, alat dan teknisi memenuhi persyaratan untuk pengujian. Validasi alat perlu dilakukan tersendiri. Spektrofotometer UV-VIS yang ada di Poltekkes Kemenkes Pontianak memiliki banyak kelebihan diantaranya rentang gelombang yang lebih lebar 190 – 1100 nm, menggunakan sistem optik double beam, memiliki bandwidth spektrum 2 nm, namun penggunaannya belum maksimal. Maka perlu dilakukan validasi terhadap spektrofotometer UV-VIS tersebut. Tujuan penelitian ini untuk mengetahui presisi, akurasi, linearitas, batas deteksi (LOD) dan batas kuantitasi (LOQ) pada Spektrofotometer uv-vis pada analisis formalin di Poltekkes Kemenkes Pontianak. Penelitian ini menggunakan desain pre-experimental metode purposive sampling dengan populasi standar formalin. Sampel yang digunakan yaitu standar formalin dengan berbagai konsentrasi 0 ppm , 1 ppm, 2 ppm, 3 ppm, 4 ppm dan 5 ppm dengan pengulangan sebanyak sembilan kali. Sampel direaksikan dengan asam kromatofat, perubahan warna menjadi ungu menunjukkan sampel mengandung formalin, kemudian diukur nilai absorbansinya untuk mendapatkan kadar formalin dalam sampel. Hasil penelitian nilai presisi 94.43%, nilai akurasi 97.77%, uji linearitas pada rentang konsentrasi 0 – 10 ppm memberikan nilai koefsien korelasi r = 0.918 dengan batas deteksi (LOD) formalin 4.98 ppm dan batas kuantitasi (LOQ) 16.60 ppm. Berdasarkan hasil penelitian dapat disimpulkan bahwa spektrofotometer UV-VIS pada analisis formalin di Poltekkes Kemenkes Pontianak tervalidasi dengan baik karena terpenuhinya kriteria lima parameter validasi.
APA, Harvard, Vancouver, ISO, and other styles
27

Irdhawati, Irdhawati, Liana Sari, and Ida Ayu Raka Astiti Asih. "TEKNIK VOLTAMETRI PELUCUTAN ANODIK GELOMBANG PERSEGI UNTUK PENENTUAN KADAR LOGAM Cu DALAM KANGKUNG AIR." Jurnal Kimia Riset 1, no. 2 (December 21, 2016): 122. http://dx.doi.org/10.20473/jkr.v1i2.3094.

Full text
Abstract:
ABSTRAK Analisis logam berat Cu(II) dilakukan dengan metode voltametri pelucutan anodik gelombang persegi. Penelitian ini bertujuan untuk mengetahui validitas metode voltametri pelucutan anodik yang digunakan dalam pengukuran kadar logam Cu(II) dalam sampel kangkung air di muara sungai Badung. Elektroda glassy carbon digunakan sebagai elektroda kerja, Ag/AgCl sebagai elektroda pembanding, dan kawat platina sebagai elektroda pembantu. Parameter yang dioptimasi meliputi waktu deposisi dan laju pindai dalam larutan standar Cu(II) 500 ppb. Validasi metode ditentukan dengan menentukan rentang konsentrasi linier, limit deteksi, keberulangan pengukuran, dan persen perolehan kembali. Teknik voltametri pelucutan anodik kemudian digunakan untuk mengukur kadar logam Cu(II) pada sampel kangkung air.Hasil optimasi pengukuran kadar logam Cu(II) yaitu waktu deposisi optimum 60 detik dan laju pindai optimum 10 mV/detik. Pengukuran validitas larutan standar logam Cu(II), rentang konsentrasi linier larutan 50 ~500 ppb dan memiliki nilai koefisien korelasi 0,9983. Limit deteksi 35 ppb, keberulangan pengukuran memiliki rasio Horwitz kurang dari 2, dan persen perolehan kembali 99,35% ± 0,4526. Hasil pengukuran sampel tanaman kangkung memiliki kandungan logam Cu(II) sebesar 4,0 ppm. Berdasarkan Keputusan Direktur Jenderal Pengawasan Obat dan Makanan batas maksimum cemaran logam dalam makanan untuk logam Cu(II) adalah 5,0 ppm. Oleh karena itu dapat diketahui bahwa kandungan logam Cu(II) tidak melebihi kadar maksimum yang diperkenankan. Kata Kunci : logam berat, voltametri pelucutan anodik gelombang persegi, kangkung airABSTRACTHeavy metal analysis of Cu(II) was measured by square wave anodic stripping voltammetry method. The aim of this research is to know the validity of square wave anodic stripping voltammetry method for determination of Cu(II) in water spinach from the estuary of Badung river. Glassy carbon, Ag/AgCl, and Pt wire electrodes were used as working electrode, reference electrode and counter electrode, respectively. Optimized parameter involved the deposition time and scan rate in standard solution Cu(II) 500 ppb. Furthermore, the validation method was examined by determination of linear concentration range, limit of detection, repetition of measurement, and percent of recovery. Moreover, the result of validation was used for observing of heavy metal Cu(II) content in water spinach. The result of optimum deposition time is 60 s. Meanwhile, the scan rate optimum is 10 mV/s. Measurement for standard solution 50 ~ 500 ppb on linear concentration range, with correlation coefficient 0,9983. Limit of detection is 35 ppb, repetition of measurement for metal has Horwitz ratio less than 2, and percent recovery of Cu(II) measurement is 99,35% ± 0,4526. The measurement of Cu(II) content in the water spinach sample contain Cu(II) 4,0 ppm. Based on Decree of Directorate General for Drug and Food Control, the treshold line for Cu(II) contamination for food is 5,0 ppm. Therefore, the water spinach sample contain Cu(II) is less than accepted value. Keyword : Heavy metal, square wave anodic stripping voltammetry, water spinach
APA, Harvard, Vancouver, ISO, and other styles
28

Salman, Salmita. "Survei Parameter Fisika-Kimia Perairan dan konsentrasi Logam Berat Pada Kerang Hijau Di Pulau Reklamasi C Dan D, Teluk Jakarta." Bio-Lectura 7, no. 2 (October 23, 2020): 11–18. http://dx.doi.org/10.31849/bl.v7i2.4697.

Full text
Abstract:
ABSTRAK: Survei perlu dilakukan untuk memperoleh informasi konsentrasi logam berat di habitat buatan dan biota laut. Tujuan dari penelitian ini adalah mengidentifikasi faktor fisika-kimia lingkungan perairan terkait kehadiran logam berat dan mengidentifikasi kandungan logam berat pada kerang hijau (Perna viridis) di sekitar Pulau Reklamasi. Pengambilan sampel di lapangan dilakukan pada bulan Agustus 2017 di Pulau Reklamasi C dan D. Pengukuran nilai logam berat mengacu pada metode SNI 3554-2015. Data dianalisis secara deskriptif kuantitatif terhadap parameter-parameter fisika-kimia perairan dan kandungan logam berat pada kerang hijau. Hasil penelitian menunjukan kebutuhan oksigen biologi (BOD), kebutuhan oksigen kimiawi (COD) telah melebihi baku mutu air yang menunjukkan tingginya tingkat pencemaran. Hasil pemeriksaan logam berat pada air laut menunjukkan bahwa merkuri (Hg), kadmium (Cd), dan timbal (Pb) berada di bawah batas deteksi alat yang digunakan (<0,0002; <0,00011; <0,00086 mg/L) dan di bawah baku mutu air laut untuk biota. Konsentrasi logam berat merkuri, kadmium dan timbal pada sedimen di sekitar Pulau Reklamasi masih berada di bawah baku mutu logam berat pada sedimen. Kadar logam berat merkuri (Hg) di bawah batas deteksi alat (<0,0004 mg/L); kadmium (Cd) berkisar antara 0,02-0,20 mg/L; timbal (Pb) berkisar antara 0,50-5,46 mg/L. Hasil pemeriksaan logam berat pada kerang hijau menunjukkan bahwa merkuri (Hg), kadmium (Cd), dan timbal (Pb) berada di bawah batas deteksi alat yang digunakan (<0,009; <0,00011; <0,00086 mg/L) dan dibawah baku mutu logam berat pada jenis kerang-kerangan. ABSTRACT: Surveys need to be conducted to obtain information on heavy metal content in man-made habitat and biota. The purposes of this research are to identify physical-chemical factors of the aquatic environment related to the presence of heavy metals and to identify the content of heavy metals in green mussels (Perna viridis) around the Reclamation Island. Field sampling was conducted in August 2017 in Reclamation Islands C and D. Measurement of heavy metal values refers to the SNI method 3554-2015. Data were analyzed with quantitative descriptive on the physical-chemical parameters of seawater and the content of heavy metals in green mussels. The results show biological oxygen demand (BOD), chemical oxygen demand (COD) had exceeded the water quality standard which indicates high level of pollution. The results of the examination of heavy metals in seawater show that mercury (Hg), cadmium (Cd), and lead (Pb) are below the tools detection limit (<0,0002; <0,00011; <0,00086 mg/L) and below water pollution standards for biota. Concentrations of heavy metals mercury, cadmium, and lead in sediments around the reclaimed islands area are below heavy metal pollution standards for sediments. Mercury (Hg) levels below the tools detection limit (<0.0004 mg/L); cadmium (Cd) ranges from 0.02-0.20 mg/L; lead (Pb) ranges from 0.50 to 5.46 mg/L. Heavy metals examination in green mussels indicate that mercury (Hg), cadmium (Cd), and lead (Pb) are below the tools detection limit (<0.001; <0.00011; <0.00086 mg/L) and below the heavy metal pollution standard on bivalves.
APA, Harvard, Vancouver, ISO, and other styles
29

Pratama, Dian Septiani, Purna Pirdaus, Rinawati Rinawati, Sophia L. Sagala, and Ifan Suhelmi R. Suhelmi. "VALIDASI METODE ANALISIS LOGAM Na, K, Mg dan Ca PADA AIR TUA (BITTERN) MENGGUNAKAN MICROWAVE PLASMA-ATOMIC EMISSION SPECTROMETER (MP-AES)." Jurnal Standardisasi 17, no. 3 (September 1, 2016): 187. http://dx.doi.org/10.31153/js.v17i3.318.

Full text
Abstract:
<p>Abstrak<br />Penelitian ini dilakukan untuk memperoleh metode analisis dan unjuk kerja metode analisis logam mayor (Na, K, Mg dan Ca) dalam air tua(bittern) menggunakan Microwave Plasma-Atomic Emission Spectrometer. Diketahui bahwa karakteristik air tua memiliki matriks kompleks yang disebabkan oleh tingginya mineral anorganik yang terkandung didalamnya. Oleh karenanya, metode analisis yang digunakan menerapkan larutan standar multi elemen mendekati matriks air tua. Karakteristik kinerja dari metode ini ditentukan dengan uji larutan standar multielement (Na, K, Mg dan Ca), dan unspiked sampel. Selektivitas, linearitas, akurasi, presisi, deteksi dan batas kuantifikasi dari hasil analisis yang diperoleh kemudian dievaluasi. Efek matriks yang signifikan tidak teridentifikasi untuk semua elemen yang dianalisis. Linearitas (r) metode analisis untuk elemen Na, K, Mg dan Ca berkisar antara 0,9955 - 0,9998. Hasil uji akurasi menunjukkan bahwa tidak ada penyimpangan dari nilai benar untuk semua elemen yang dianalisa. Presisi yang disajikan dalam relative standard deviation (%RSD) untuk analisa Na, K, Mg dan Ca berturut-turut adalah: 1,491; 2,702; 2,678; dan 1,923. Sedangkan batas deteksi untuk parameter Na, K, Mg, dan Ca berturut-turut adalah: 0,184; 0,070; 0,219 dan 0,005 mg/l dengan batas kuantifikasi 0,613; 0,230; 0,730 dan 0,017mg/l. Hasil validasi tersebut menunjukkan bahwa metode yang diusulkan selektif dan sesuai untuk untuk analisis air tua.<br />Kata kunci : validasi metode analisis, air tua, logam (Na, K, Mg, Ca), MP-AES.</p><p><br />Abstract<br />This research aims to obtain analysis method for mayor elements (Na, K, Mg, and Ca) in bittern using Microwave Plasma-Atomic Emission Spectrometry (MP-AES) and to assess the validity of the obtained method. It is known that sea bittern characteristic has complex matrix for its high concentration of the inorganic materials. Therefore assessment of the validity of the analytical method for mayor element is important. The performance characteristics of the method were established by multi-elements-standard-solution assay (Na, K, Mg and Ca), in which samples were un-spiked. Selectivity, linearity, accuracy, precision, detection and quantification limit of the method were evaluated in the study. Matrix effects were not significantly identified for the studied elements. Linearity of selected concentration range for Na, K, Mg and Ca varied from 0.9955- 0.9998. No deviation of true value for all elements was observed in the accuracy test. Meanwhile, precision values of the method (%RSD) were 1.491; 2.702; 2.678; and 1.923, respectively for Na, K, Mg and Ca. The method developed in the present study indicated the detection limits for Na, K, Mg and Ca were 0,184; 0,070; 0,219 dan 0,005 mg/l, respectively, with quantification limits of 0,613; 0,230; 0,730 dan 0,017mg/l. The results of the validation method showed that the proposed method is selective and feasible for sea bittern analysis using MP-AES. Keywords: Method validation, Bittern, Na, K, Mg, Ca, MP-AES.</p>
APA, Harvard, Vancouver, ISO, and other styles
30

Handajani, Usreg Sri, Cahya Nurrahmi H. Amilianti, and Miratul Khasanah. "PENGEMBANGAN ELEKTRODA PASTA KARBON TERMODIFIKASI MIP DENGAN MONOMER ASAM METAKRILAT SEBAGAI SENSOR PADA ANALISIS KREATIN SECARA POTENSIOMETRI." Jurnal Kimia Riset 2, no. 2 (December 14, 2017): 131. http://dx.doi.org/10.20473/jkr.v2i2.6699.

Full text
Abstract:
Pada penelitian ini telah dilakukan pengembangan elektroda pasta karbon/MIP untuk analisis kreatin secara potensiometri. Pemilihan teknik imprinting bertujuan untuk membentuk cetakan yang sesuai dengan sisi aktif kreatin pada MIP. Elektroda yang dibuat dari campuran karbon aktif, parafin, dan MIP dengan perbandingan 11:7:2 bagian menunjukkan kinerja optimum. Kinerja elektroda pasta karbon/MIP ditunjukkan oleh nilai faktor Nernst dan linieritas pengukuran yaitu 27,2 mV/dekade dan 0,9915 pada konsentrasi jangkauan pengkuran 10-6-10-2 M, limit deteksi sebesar 1,1x10-6 M, akurasi 55-125,8%, dan nilai koefisien variasinya 0,27-0,60%. Elektroda masih memberikan kinerja yang baik hingga pemakaian ke-85. Uji selektivitas terhadap elektroda dilakukan dengan menggunakan matriks glukosa dan menunjukkan hasil bahwa glukosa pada konsentrasi rendah dan normal dalam darah tidak mengganggu analisis kreatin, tetapi glukosa pada konsentrasi tinggi mengganggu proses analisis kreatin.
APA, Harvard, Vancouver, ISO, and other styles
31

Tea, Marselina Theresia Djue. "ANALISIS DIAZINON PADA TANAH LAHAN PERTANIAN MENGGUNAKAN KROMATOGRAFI CAIR KINERJA TINGGI." Jurnal Saintek Lahan Kering 3, no. 1 (June 13, 2020): 26–28. http://dx.doi.org/10.32938/slk.v3i1.1021.

Full text
Abstract:
Suatu metode untuk penentuan diazinon dalam sampel tanah telah dikembangkan. Analit diekstraksi dengan asetonitril dari sampel tanah pertanian. Penentuan dan kuantifikasi diazinon dilakukan dengan menggunakan kromatografi cair kinerja tinggi (KCKT) dengan detektor UV. Kondisi optimal untuk analisis diazinon adalah komposisi eluen asetonitril: air 60:40, laju aliran 0,4 mL/menit, dan panjang gelombang 220 nm. Di bawah kondisi optimal, liniearitas diazinon pada konsentrasi 1-25 ppm dengan R2 mendekati 1 yaitu 0,9976. Batas deteksi (LOD) diazinon sebesar 1,19 ppm, sedangkan limit kuantifikasi (LOQ) diazinon sebesar 3,98 ppm. Ketika metode ini diterapkan pada sampel tanah, % recovery diazinon diatas 80%. Maka dapat dikatakan bahwa metode ini valid dan layak untuk analisis senyawa diazinon dalam tanah. Konsentrasi diazinon dalam sampel tanah berada di bawah LOD dan LOQ (0,577 mgL-1). Oleh karena itu, dapat disimpulkan bahwa sampel tanah yang digunakan dalam penelitian ini tidak mengandung diazinon.
APA, Harvard, Vancouver, ISO, and other styles
32

Puspitasari, Riris Lindiawati, Dewi Elfidasari, Yorianta Sasaerila, Fatihah Dinul Qoyyimah, and Fatkhurokhim Fatkhurokhim. "Deteksi Bakteri Pencemar Lingkungan (Coliform) Pada Ikan Sapu-Sapu Asal Sungai Ciliwung." JURNAL Al-AZHAR INDONESIA SERI SAINS DAN TEKNOLOGI 4, no. 1 (January 31, 2018): 24. http://dx.doi.org/10.36722/sst.v4i1.244.

Full text
Abstract:
<p><em>Abstrak</em><strong> - Sungai Ciliwung merupakan salah satu sumber kehidupan bagi masyarakat. Berdasarkan survey yang dilakukan, ikan sapu-sapu sungai Ciliwung juga dimanfaatkan sebagai pangan oleh masyarakat. Penelitian ini bertujuan untuk mendeteksi keberadaan bakteri Coliform dan mikroorganisme yang terdapat pada ikan sapu-sapu asal perairan sungai Ciliwung. Deteksi Coliform dilakukan dengan metode uji praduga dan uji konfirmasi terhadap insang, usus, daging serta kulit abdomen ikan sapu-sapu. Uji praduga dengan menggunakan media Lactose Broth (LB), sedangkan uji konfirmasi dengan media Brilliant Lactose Broth (BGLB). Hasil MPN dilihat dari tabel yang memberikan nilai duga terdekat dengan kombinasi tabung positif dan tabung negatif pada uji konfirmasi. Hasil yang didapat menunjukan seluruh sampel memiliki nilai MPN melebihi batas maksimum Coliform pada makanan. Jadi daging, insang, kulit abdomen, dan usus pada ikan sapu-sapu tidak layak untuk dikonsumsi oleh masyarakat.</strong></p><p><em><strong>Kata Kunci</strong> - Coliform, ikan sapu-sapu, sungai Ciliwung</em></p><p><em>Abstract</em><strong> - Ciliwung River is one of life source for society. Based on the survey conducted, Ciliwung river broom fish is also used as food by the community. This study aims to detect the presence of Coliform bacteria and microorganisms found in broom fish from the Ciliwung River waters. Coliform detection was performed by presumptive test method and confirmation test on gills, intestines, meat and abdominal skin of sweeper fish. Prediction test using Lactose Broth (LB) media, while confirmation test with Brilliant Lactose Broth (BGLB) media. MPN results are seen from the table that gives the closest possible value to the positive tube and negative tube combination in the confirmation test. The results show that all samples have MPN values exceeding the maximum limit of Coliform in foods. So the meat, the gills, the abdominal skin, and the intestines in the broom fish are not fit for consumption by the public.</strong></p><p><em>Keywords</em> - Coliform, Cattle Fish, River Cilliwung</p>
APA, Harvard, Vancouver, ISO, and other styles
33

Fatmawati, Sofia, Hurip Budi Riyanti, and Kori Yati. "Pelatihan Deteksi Formalin dan Rhodamin B dalam Makanan bagi Guru dan Wali Murid TK Bintara Jaya Bekasi." JPM (Jurnal Pemberdayaan Masyarakat) 5, no. 1 (May 4, 2020): 350–57. http://dx.doi.org/10.21067/jpm.v5i1.3328.

Full text
Abstract:
People in general, consumes food which is homecooked or buying finished products every day. Many types of prepared fast foods used food additives such as preservatives, flavorings agents, sweeteners etc. Additives which being used must be safe for consumption in a certain limit. The community service was held to the teachers and parents from Bintara Jaya Bekasi Kindergarten in order to quickly detect additional ingredients of fformaldehyde and rhodamine in food and using a test kit. The target is to increase the knowledge and skills of the teachers and parents from Bintara Jaya Bekasi Kindergarten students to detect and test foods containing formaldehyde and rhodamine B because the commons does not yet understand between safe and prohibited food additives. This workshop can improve the quality of health in the school and family environment. The training was done by lecturing method, practicing rapid detection and using a test kit and followed by discussion. The results of the community service showed an increase in the knowledge and skills of the teachers and parents from Bintara Jaya Bekasi Kindergarten in detecting foods containing formaldehyde and rhodamine B.
APA, Harvard, Vancouver, ISO, and other styles
34

Latubessy, Anastasya, Ahmad Jazuli, and Rina Fiati. "Penerapan Intelligent Geographic Information System untuk Deteksi Kecanduan Game." Jurnal Teknologi Informasi dan Ilmu Komputer 7, no. 6 (December 2, 2020): 1147. http://dx.doi.org/10.25126/jtiik.2020722185.

Full text
Abstract:
<p class="Abstrak">Segala sesuatu yang berlebihan dapat menimbulkan efek kecanduan. Hal yang sama juga berlaku untuk <em>game. Game </em>dapat<em> </em>memberikan efek adiksi yang mengakibatkan pemainnya ketagihan. Pemain <em>game </em>tidak mengenal batas usia. Anak-anak bahkan anak usia dini sudah bermain <em>game</em> dengan menggunakan <em>gadget</em>, sebagai akibat dari perkembangan teknologi saat ini. Kecanduan <em>game</em> dapat berdampak negatif pada anak usia dini. Penelitian terdahulu menunjukkan adanya hubungan korelasi negatif antara kecanduan <em>game</em> dengan proses pembelajaran. Meninjau hal tersebut, maka orang tua perlu waspada terhadap pola permainan <em>game</em> anak. Penelitian terdahulu menghasilkan aplikasi untuk mendeteksi tingkat kecanduan <em>game </em>anak dengan menggunakan salah satu metode dalam sistem pakar yaitu <em>backward chaining</em> untuk identifikasi gejala kecanduan <em>game</em>. Penelitian saat ini mengkombinasi teknologi pakar pada aplikasi sebelumnya dengan teknologi <em>Geographic</em> <em>Information</em> <em>System</em> untuk mendeteksi kecanduan <em>game</em> anak dan memetakan persebarannya di wilayah Indonesia bagian timur, barat dan tengah. Penelitian ini menggunakan metode perancangan sistem <em>waterfall, </em>yang dimulai dari identifikasi masalah, analisa masalah, perancangan sistem, implementasi dan pengujian sistem.<em> </em>Sehingga menghasilkan aplikasi yang diberi nama IGIS-Decandu(<em>Intelligent Geographic Information System</em> Deteksi Kecanduan <em>Game</em>) yang dapat digunakan untuk mengetahui tingkat persebaran kecanduan <em>game </em>anak Indonesia. Hasil uji coba untuk pengujian identifikasi kecanduan <em>game</em> antara sistem IGIS-Decandu dan ujicoba manual memperoleh nilai Kappa sebesar 1.0. Berdasarkan pengujian tersebut, dapat disimpulkan bahwa sistem IGIS-Decandu siap untuk digunakan secara umum, karena proses identifikasi kecanduan <em>game</em> valid dengan nilai keeratan kesepakatan antara pengujian sistem dan manual adalah 1.00 yang berarti “Sangat Kuat”.</p><p class="Abstrak"> </p><p class="Judul2"><strong><em>Abstract</em></strong></p><p class="Abstract">Anything that is excessive can have an addictive effect. The same thing applies to games. Games can have an addictive effect that results in players being addicted. Gamers don't know the age limit. Children and even young children are already playing games using gadgets, as a result of current technological developments. Game addiction can have a negative impact on early childhood. Previous research has shown a negative correlation between game addiction and the learning process. Reviewing this, parents need to be aware of the pattern of children's game play. Previous research has made an application to detect the level of addiction to children's by using one method in the expert system that is backward chaining to identify the symptoms of game addiction. Current research combines expert technology in previous applications with Geographic Information System technology to detect children's gaming addictions and map their distribution in eastern, western and central Indonesia. This study uses a waterfall system design method, which start from identification, problem analysis, design system, implementation system and testing system to produce an application called IGIS-Decandu (Intelligent Geographic Information System for Game Addiction Detection) that can be used to determine the level of distribution of Indonesian children's game addiction. The results of trials for testing the game addiction identification between the IGIS-Decandu system and manual testing obtained a Kappa value of 1.0. Based on these tests, it can be concluded that the IGIS-Decandu system is ready for general use, because the process of identifying game addiction is valid with the value of the agreement between the system and manual testing being 1.00 which means "Very Strong"</p><p class="Judul2"><strong><em><br /></em></strong></p>
APA, Harvard, Vancouver, ISO, and other styles
35

Irzon, Ronaldo, and Kurnia Kurnia. "SKEMA FIRE ASSAY DAN ICP-MS PADA PENGUKURAN KADAR PALADIUM DALAM SAMPEL BATUAN." Majalah Ilmiah Pengkajian Industri 13, no. 2 (September 2, 2019): 187–94. http://dx.doi.org/10.29122/mipi.v13i2.3263.

Full text
Abstract:
Paladium adalah anggota Platinum Grup Element yang berjumlah kecil di kerak Bumi, namun memiliki harga jual yang tinggi. Logam ini sangat dibutuhkan oleh industri otomotif, industri pesawat ruang angkasa, dan industri perhiasan. Akurasi pengukuran Pd yang baik pada sampel diperlukan untuk mendukung industri terkait. Penelitian ini bertujuan untuk menjabarkan akurasi pengukuran paladium yang memanfaatkan skema fire assay dalam pra-konsentrasi dan ICP-MS sebagai perangkat pengukuran. Sampel yang dipergunakan adalah bahan internal standar Serpentin milik Laboratorium Geologi. Limit deteksi cukup rendah pada 1,0057 ppb yang ditentukan melalui skema regresi linear. Stabilitas kinerja perangkat sangat baik yang ditunjukkan oleh rentang deviasi 0-1,96%. Prosedur fire assaying yang belum sempurna disimpulkan menjadi penyebab perbedaan hasil pengukuran kadar Pd pada sampel. Rangkaian proses dalam studi ini dinilai akurat yang mengacu pada besaran spike recovery <112%. Studi ini dapat dikembangkan dengan memperbesar rentang kalibrasi analisis agar dapat mengakomodasi kisaran jumlah analit yang lebih luas pada sampel
APA, Harvard, Vancouver, ISO, and other styles
36

Zaidah, Lailatuz, and Dika Rizki Imania. "PELATIHAN DETEKSI DINI MENCEGAH TERJADINYA STROKE PADA LANSIA PIMPINAN RANTING ‘AISYIYAH ALUN-ALUN UTARA KOTAGEDE YOGYAKARTA." Jurnal Pengabdian Masyarakat Multidisiplin 4, no. 1 (October 28, 2020): 48–54. http://dx.doi.org/10.36341/jpm.v4i1.1491.

Full text
Abstract:
ABSTRAK Latar belakang :Stroke adalah gejala-gejala defisitfungsi saraf yang diakibatkan oleh penyakit pembuluh darah otak, bukan oleh sebab yang lain (WHO). Gangguan fungsi syaraf pada stroke disebabkan oleh gangguan peredaran darah otak non traumatik. Gangguan syaraf tersebut menimbulkan gejala antara lain: kelumpuhan wajah atau anggota badan, bicara tidak lancar, bicara tidak jelas (pelo), perubahan kesadaran, gangguan penglihatan, dan lain-lain. Stroke merupakan penyebab disabilitas nomor satu dan penyebab kematian nomor dua di dunia setelah penyakit jantung iskemik baik di negara maju maupun berkembang. Metode : pelatihan ini dilakukan dengan metode ceramah dan apllikasi kepada kader dan lansia di PRA Alun-alun Utara kotagede Tujuan: Bertambahnya pengetahuan kader posyandu dan ibu ‘Aisyiyah Alun-Alun Utara tentang gangguan pembuluh darah otak, tentang deteksi dini terjadinya stroke serta pelatihan dalam mencegah terjadinya stroke. Hasil para Kader lansia mampu melakukan cara bagaimana deteksi dini stroke dengan melakukan pengukuran tensi darah serta mampu mengetahui batas normal dari nilai kadar kolesterol dan gula darah, Rekomendasi kegiatan ini bisa dilakukan secara rutin dengan diadakannya posyandu lansia Kata Kunci: Stroke, Deteksi Dini stroke, pencegahan stroke ABSTRACT Background: Stroke is a symptom of nerve deficit function caused by cerebral vascular disease, not by other causes (WHO). Nerve function disorders in stroke are caused by non-traumatic brain circulatory disorders. This nerve disorder causes symptoms, including: paralysis of the face or limbs, speech is not fluent, speech is not clear (pelo), Stroke is the number one cause of disability and the number two cause of death in the world after ischemic heart disease in both developed and developing countries. Methods: This training was conducted by lecturing and applying to cadres and the elderly at PRA Alun-alun Utara, Kotagede. Objectives: Increasing the knowledge of posyandu cadres and 'Aisyiyah Alun-Alun Utara' about brain blood vessel disorders, early detection of stroke and training in preventing the occurrence of a stroke. The results of the elderly cadres are able to do how to detect stroke early by measuring blood pressure and being able to know the normal limit of the value of cholesterol and blood sugar levels. Recommendations for this activity can be done regularly by holding posyandu for the elderly Keywords: Stroke, Stroke Early Detection, Stroke Prevention
APA, Harvard, Vancouver, ISO, and other styles
37

Hadi, Anwar. "PENENTUAN BATAS DETEKSI METODE (METHOD DETECTION LEVEL) DAN BATAS KUANTIFIKASI (LIMIT OF QUANTITATION) PENGUJIAN SULFIDA DALAM AIR DAN AIR LIMBAH DENGAN BIRU METILEN SECARA SPEKTROFOTOMETRI." Jurnal Ecolab 4, no. 2 (December 1, 2010): 70–80. http://dx.doi.org/10.20886/jklh.2010.4.2.70-80.

Full text
APA, Harvard, Vancouver, ISO, and other styles
38

Irdhawati, Irdhawati, Ni Putu Antari Dewi, and Ida Ayu Gede Widihati. "Teknik Differential Pulse Voltammetry Menggunakan Elektroda Pasta Karbon Termodifikasi Fe2O3 untuk Penentuan Kadar Fe(III) dalam Air Laut di Pelabuhan Benoa Bali." ALCHEMY Jurnal Penelitian Kimia 17, no. 1 (March 8, 2021): 54. http://dx.doi.org/10.20961/alchemy.17.1.41568.54-62.

Full text
Abstract:
<p>Pelabuhan Benoa merupakan salah satu pelabuhan di Provinsi Bali tempat berlabuhnya kapal/perahu nelayan, kapal penumpang, dan kapal untuk pariwisata. Aktivitas masyarakat di sekitar pelabuhan dapat menjadi sumber pencemar logam berat. Penelitian ini bertujuan untuk mengetahui hasil optimasi dan validasi elektroda pasta karbon tanpa modifikasi (EPK) dan EPK termodifikasi Fe<sub>2</sub>O<sub>3</sub> (EPK Fe<sub>2</sub>O<sub>3</sub>) dengan teknik <em>differential pulse voltammetry</em> (DPV) untuk pengukuran Fe(III) dalam sampel air laut di Pelabuhan Benoa. Parameter yang dioptimasi yaitu laju pindai dan komposisi Fe<sub>2</sub>O<sub>3</sub> dalam pasta karbon. Selanjutnya dilakukan validasi pengukuran, meliputi rentang konsentrasi linier, limit deteksi, limit kuantisasi, keberulangan, dan persen perolehan kembali. Hasil yang diperoleh yaitu laju pindai optimum 15 mV/s menggunakan EPK, menjadi<ins cite="mailto:Microsoft%20Office%20User" datetime="2021-02-27T20:39"> </ins>lebih cepat yaitu 20 mV/s menggunakan EPK Fe<sub>2</sub>O<sub>3</sub>. Komposisi <em>modifier</em> terbaik dalam pasta karbon sebesar 0,5%. Rentang konsentrasi linier pengukuran menggunakan EPK yaitu 5 ~ 100 mg/L menjadi 5 ~ 2000 mg/L pada EPK Fe<sub>2</sub>O<sub>3. </sub>Limit deteksi dan limit kuantisasi menggunakan EPK Fe<sub>2</sub>O<sub>3 </sub>masing-masing 0,5490 mg/L dan 0,5497 mg/L, lebih rendah daripada menggunakan EPK yaitu 1,0667 mg/L dan 1,0688 mg/L. Keberulangan pengukuran menghasilkan rasio Horwitz yang lebih kecil dari dua. Nilai persen perolehan kembali pengukuran larutan standar dengan matriks larutan sampel yang diambil pada tiga lokasi yang berbeda, yaitu pada Dermaga Barat 97,51±9,92% ; Dermaga Selatan 101,18±10,60%; dan Dermaga Timur 95,50±1,23%. Hasil pengukuran Fe(III) dalam sampel diperoleh 129,98±13,65 mg/L; 114,85±13,75 mg/L; dan 127,77±4,01 mg/L, masing-masing pada Dermaga Barat, Selatan, dan Timur.</p><p><strong>Differential Pulse Voltammetry Technique Using Fe<sub>2</sub>O<sub>3</sub> Modified Carbon Paste Electrode for Determination of Fe(III) Levels in Seawater at Benoa Harbor Bali. </strong>Benoa Port is one of the ports in the Province of Bali where fishing boats, passenger ships, and ships for tourism are anchored. Activities around the port can be a source of heavy metal pollutants. This study aims to optimize and validates carbon paste electrodes without modification (EPK) and modified by Fe<sub>2</sub>O<sub>3</sub> (EPK Fe<sub>2</sub>O<sub>3</sub>) using differential pulse voltammetry (DPV) techniques for Fe (III) measurements in seawater at Benoa Harbor. The optimized parameters were scan rate and the Fe<sub>2</sub>O<sub>3</sub> composition in carbon paste. Meanwhile, the validation was performed, including the range of linear concentration, detection limit, quantitation limit, repeatability, and percent of the recovery. The research found that the optimum scan rate was 15 mV/s using EPK, become faster to 20 mV/s using EPK Fe<sub>2</sub>O<sub>3</sub>. The optimum <em>modifier</em> composition in carbon paste was 0.5%. The linear concentration range of measurement using EPK was 5 ~ 100 mg/L to 5 ~ 2000 mg/L at EPK Fe<sub>2</sub>O<sub>3</sub>. The detection limit and the quantitation limit using EPK Fe<sub>2</sub>O<sub>3</sub> were 0.5490 mg/L and 0.5497 mg/L, respectively. Those are lower than the detection limit quantitation by EPK i.e., 1.0667 mg/L and 1.0688 mg/L, respectively. Repeated measurements produce a Horwitz ratio which is less than two. The percent of recovery value of the measurement of the standard solution with the sample solution matrix taken from the three different locations are 97.51±9.92% for the West Pier region; 101.18±10.60% for the South Pier region; and 95.50±1.23% for the East Pier region. The Fe(III) measurements to the different samples from the West Pier, South Pier, and East Pier regions were 129.98±13.65 mg/L; 114.85±13.75 mg/L; and 127.77±4.01 mg/L, respectively.</p>
APA, Harvard, Vancouver, ISO, and other styles
39

Kusmartini, Indah, Natalia Adventini, Dyah Kumala Sari, Syukria Kurniawati, Diah Dwiana Lestiani, and Muhayatun Santoso. "KARAKTERISASI UNSUR PM 2,5 PADA PERIODE KEBAKARAN HUTAN DI PEKANBARU DENGAN TEKNIK ANALISIS AKTIVASI NEUTRON." Jurnal Sains dan Teknologi Nuklir Indonesia 20, no. 1 (February 28, 2019): 29. http://dx.doi.org/10.17146/jstni.2019.1.1.4655.

Full text
Abstract:
Kebakaran hutan merupakan salah satu penyebab kerusakan hutan yang berdampak pada penurunan kualitas lingkungan. Untuk mengetahui dampak kualitas udara akibat kebakaran hutan, telah dilakukan karakterisasi dan evaluasi cuplikan partikulat udara yang dikumpulkan pada periode terjadinya kebakaran hutan di Pekanbaru. Karakterisasi cuplikan telah dilakukan dengan metode AAN yang memiliki beberapa kelebihan antara lain sensitivitas tinggi, multiunsur dan limit deteksi yang rendah. Validasi metode dilakukan pengujian terhadap cuplikan bahan acuan SRM NIST 1648a Urban Particulate Matter. Konsentrasi massa saat terjadi kebakaran hutan di Pekanbaru terdeteksi 5 hingga 7 kali lebih tinggi dari kondisi normal. Hasil karakterisasi cuplikan telah terkuantifikasi 15 unsur (Al, Ca, Ti, Cl, Mn, As, Br, Na, K, As, Fe, Zn, Cr, Co, Sb). Output dari kegiatan ini diharapkan dapat menggambarkan unsur utama yang menjadi indikator sumber pencemar yang selanjutnya dapat digunakan sebagai early warning dalam mengantisipasi bencana kebakaran hutan. Selain itu evaluasi unsur karsinogenik dan non-karsinogenik dapat menunjukkan resiko kesehatan masyarakat di sekitar lokasi kebakaran hutan yang secara tidak langsung dapat terpapar oleh emisi sumber partikulat udara.
APA, Harvard, Vancouver, ISO, and other styles
40

Gde Agung Brahmana Suryanegara, Adiwijaya, and Mahendra Dwifebri Purbolaksono. "Peningkatan Hasil Klasifikasi pada Algoritma Random Forest untuk Deteksi Pasien Penderita Diabetes Menggunakan Metode Normalisasi." Jurnal RESTI (Rekayasa Sistem dan Teknologi Informasi) 5, no. 1 (February 20, 2021): 114–22. http://dx.doi.org/10.29207/resti.v5i1.2880.

Full text
Abstract:
Diabetes is a disease caused by high blood sugar in the body or beyond normal limits. Diabetics in Indonesia have experienced a significant increase, Basic Health Research states that diabetics in Indonesia were 6.9% to 8.5% increased from 2013 to 2018 with an estimated number of sufferers more than 16 million people. Therefore, it is necessary to have a technology that can detect diabetes with good performance, accurate level of analysis, so that diabetes can be treated early to reduce the number of sufferers, disabilities, and deaths. The different scale values for each attribute in Gula Karya Medika’s data can complicate the classification process, for this reason the researcher uses two data normalization methods, namely min-max normalization, z-score normalization, and a method without data normalization with Random Forest (RF) as a classification method. Random Forest (RF) as a classification method has been tested in several previous studies. Moreover, this method is able to produce good performance with high accuracy. Based on the research results, the best accuracy is model 1 (Min-max normalization-RF) of 95.45%, followed by model 2 (Z-score normalization-RF) of 95%, and model 3 (without data normalization-RF) of 92%. From these results, it can be concluded that model 1 (Min-max normalization-RF) is better than the other two data normalization models and is able to increase the performance of classification Random Forest by 95.45%.
APA, Harvard, Vancouver, ISO, and other styles
41

Sudayasa, I. Putu, Muhammad Fathur Rahman, Amiruddin Eso, Jamaluddin Jamaluddin, Parawansah Parawansah, La Ode Alifariki, Arimaswti Arimaswati, and Andi Noor Kholidah. "Deteksi Dini Faktor Risiko Penyakit Tidak Menular Pada Masyarakat Desa Andepali Kecamatan Sampara Kabupaten Konawe." Aksiologiya: Jurnal Pengabdian Kepada Masyarakat 4, no. 2 (May 13, 2020): 16. http://dx.doi.org/10.30651/aks.v4i2.3491.

Full text
Abstract:
ABSTRAKPenyakit tidak menular (PTM) merupakan penyakit yang tidak ditularkan dan tidak ditransmisikan kepada orang lain dengan bentuk kontak apapun, menyebabkan kematian dan membunuh sekitar 35 juta manusia setiap tahunnya, atau 60% dari seluruh kematian secara global, dengan 80% pervalensi pada negara berkembang. Penyakit tidak menular, khususnya penyakit kardiovaskuler, kanker, penyakit pernapasan kronis, dan diabetes merupakan ancaman utama bagi kesehatan dan perkembangan manusia saat ini. Tujuan pengabdian masyarakat yang terintegrasi kuliah kerja nyata (KKN) Tematik, untuk mendeteksi faktor risiko penyakit tidak menular, pada masyarakat Kecamatan Sampara, Kabupaten Konawe. Metode kegiatan berupa penyuluhan kesehatan, pemeriksaan tekanan darah, kadar kolesterol, gula darah sewaktu dan asam urat. Telah dilakukan skrining dan deteksi dini fator risiko penyakit tidak menular terhadap 67 orang responden, meliputi 14 laki–laki dan 53 perempuan. Pada hasil pemeriksaan tekanan darah, didapatkan jumlah yang mengalami hipertensi 28,35 %, normotensi 67,16, dan hipotensi 4,47 %. Pada pemeriksaan Kolesterol Total, didapatkan kolesterol dalam batas normal 2,38 % dan tinggi 37,31 %. Hasil pemeriksaan gula darah sewaktu (GDS), didapatkan kadar GDS dalam batas normal 85,07 % dan kadar GDS tinggi 14,92 %. Pada pemeriksaan Asam Urat didapatkan dalam batas normal adalah 91,04 % dan tinggi 8,95 %.Kata kunci: Faktor Risiko; Penyakit Tidak Menular Early Detection of Non-communicable Disease Risk Factors in Andepali Village Community, Sampara District, Konawe RegencyABSTRACTNon-communicable disease (PTM) is a disease that is not transmitted and is not transmitted to others by any form of contact, causing death and killing around 35 million people each year, or 60% of all deaths globally, with 80% prevalence in developing countries. PTM, especially cardiovascular disease, cancer, chronic respiratory diseases, and diabetes are the main threats to human health and development today. The purpose of integrated community service is the Thematic Real Work Study (KKN), to detect risk factors for non-communicable diseases, in the community of Sampara District, Konawe Regency. The method of activity in the form of health education, blood pressure, cholesterol levels, blood sugar and uric acid. Screening and early detection of risk factors for non-communicable diseases have been carried out on 67 respondents, including 14 men and 53 women. On the results of blood pressure examination, it was found that the amount of hypertension was 28.35%, normotension 67.16% and hypotension 4.47%. In the examination of Total Cholesterol, cholesterol was found to be within the normal limit of 2.38% and 37.31% high. Examination results of Blood Sugar (GDS), obtained levels of GDS in the normal range of 85.07% and high GDS levels of 14.92%. In the examination of Gout found in the normal range is 91.04% and high 8.95%.Keywords: gout; blood sugar; cholesterol; non-communicable diseases; blood pressure
APA, Harvard, Vancouver, ISO, and other styles
42

Suharman, S., and Siti Utari Rahayu. "Senyawa Hidrazone dari Vanilin-DNPH Sebagai Sensor Kolorimetri Anion Sianida." ALCHEMY Jurnal Penelitian Kimia 16, no. 1 (February 21, 2020): 77. http://dx.doi.org/10.20961/alchemy.16.1.34635.77-93.

Full text
Abstract:
<p>Senyawa hidrazon (<em>E</em>)-4-((2-(2,4-<em>dinitrophenyl</em>)<em>hydrazineylidene</em>)<em>methyl</em>)-2-<em>methoxyphenol</em> telah disintesis dari vanilin dan 2,4-dinitrofenilhidrazin (DNPH). Uji sensor anion dilakukan dengan menambahkan anion F<sup>-</sup>, Cl<sup>-</sup>, Br<sup>-</sup>, I<sup>-</sup>, CN<sup>-</sup>, SO<sub>4</sub><sup>2-</sup>, CO<sub>3</sub><sup>2-</sup>, CH<sub>3</sub>COO<sup>-</sup> dan H<sub>2</sub>PO<sub>4</sub><sup>-</sup> dalam pelarut asetonitril. Uji limit deteksi reseptor (<em>E</em>)-4-((2-(2,4-<em>dinitrophenyl</em>)<em>hydrazineylidene</em>)<em>methyl</em>)-2-<em>methoxyphenol</em> terhadap anion sianida dilakukan dalam pelarut asetonitril. Hasil uji sensor anion menunjukan bahwa reseptor selektif terhadap anion sianida dengan menghasilkan perubahan warna dari kuning ke merah. Hasil analisa dengan spektrofotometer UV-Vis reseptor memberikan perubahan panjang gelombang dari 395 nm menjadi 472 nm pada penambahan anion sianida. Reseptor (<em>E</em>)-4-((2-(2,4-<em>dinitrophenyl</em>)<em>hydrazineylidene</em>)<em>methyl</em>)-2-<em>methoxyphenol</em> dapat mendeteksi anion CN- dengan limit deteksi sebesar 7 mM.</p><p> </p><p><strong>A Hydrazone Compound from Vanillin-DNPH as Colorimetric Sensor of Cyanide Anion</strong><strong>.</strong> A hydrazone compound (<em>E</em>)-4-((2-(2,4-dinitrophenyl)hydrazineylidene)methyl)-2-methoxyphenol has been synthesized from vanillin and 2,4-dinitrophenylhydrazine (DNPH). The anion sensor study were done by adding Br<sup>-</sup><sub>, </sub>CN<sup>-</sup>, F<sup>-</sup>, SO<sub>4</sub><sup>2-</sup><sub>, </sub>Cl<sup>-</sup>, I<sup>-</sup> , CO<sub>3</sub><sup>2-</sup>, CH<sub>3</sub>COO<sup>-</sup> and H<sub>2</sub>PO<sub>4</sub><sup>-</sup> anion in acetonitrile solvent. The detection limit study of receptor <em>E</em>)-4-((2-(2,4-dinitrophenyl)hydrazineylidene)methyl)-2-methoxyphenol for cyanide anion was carried out in acetonitrile. The result of anion sensor study shows that the receptor was selective to cyanide anion by providing change of color from yellow to red. The analysis result using spectrophotometer ultraviolet-visible of the receptor provided change of maximum wavelength from 395 nm to 472 nm when the cyanide anion was added. Receptor (<em>E</em>)-4-((2-(2,4-dinitrophenyl) hydrazineylidene)methyl)-2-methoxyphenol can detect CN<sup>-</sup> with limit of detection 7 mM.</p><div><span><br /></span></div>
APA, Harvard, Vancouver, ISO, and other styles
43

Pawestri, Wari, Gagak Dhony Satria, Nisa Hakimah, and Doddi Yudhabuntara. "Deteksi Kejadian Residu Tetrasiklin pada Daging Ikan Nila di Kota Yogyakarta dengan Kromatografi Cair Kinerja Tinggi (KCKT)." Jurnal Sain Veteriner 37, no. 2 (December 11, 2019): 185. http://dx.doi.org/10.22146/jsv.34463.

Full text
Abstract:
Food products of animal origin which are free from biological and chemical contamination are an absolute requirement of food safety. Antibiotics residues in the food of animal origin is one of the chemical contaminants in food are harmful/hazardous to human health. Tetracycline is an antibiotic that is often used in the fishing industry. The study aims to detect the occurrence of tetracycline residues in tilapia sold in traditional markets in Kota Yogyakarta. The research was conducted with detection test (detect disease). The study used 61 samples of tilapia fish from 16 traditional markets in Kota Yogyakarta. Tilapia meat samples are prepared according to the Association of Official Analytical Chemistry (AOAC). The existence of tetracycline residues in meat can be detected by high performance liquid chromatography (HPLC). Residue analysis in fish meat was conducted at the Department of Pharmacology, Faculty of Veterinary Medicine of Gadjah Mada University using HPLC Shimadzu version 6.1. The results showed that 24 samples of tilapia meat marketed in Kota Yogyakarta was positively contained tetracycline antibiotic residues. A total of 19 samples contained residues above maximum residue limits (MRL). The conclusion of the study is 31% of tilapia marketed in Kota Yogyakarta contains tetracycline residues above MRL. Surveillance of residues in food of animal origin and further research in terms of reducing antibiotic residue in tilapia meat is highly recommended to improve the quality and safety of food of animal origin.
APA, Harvard, Vancouver, ISO, and other styles
44

Khaq, Khanifa Nurul, and Lusiawati Dewi. "DETEKSI CEMARAN BAKTERI KOLIFORM DAN Salmonella sp. PADA TEMPE YANG DIKEMAS DAUN PISANG DI DAERAH SALATIGA." Agric 28, no. 1 (January 16, 2017): 79. http://dx.doi.org/10.24246/agric.2016.v28.i1.p79-86.

Full text
Abstract:
<p>ABSTRACT</p><p>Banana leaves-wrapped tempeh is a traditional food as a conventional base of vegetable protein source. Fermented soybeans into tempeh assisted by fungi kind Rhizopusoligosporus, Rhizopusoryzae and Rhizopusstolonifer. Hygiene is very important in the process of fermentation as it will affect the end result of products. Packaging materials can serve as a protective product, but related to the materials used can be the sources of microbial contaminants in food packaging.For small-scale Tempeh industry in Salatiga area commonly use banana leaves to wrap tempeh.The absence of leaves-wrapped tempeh quality standard made the manufacturers ignore the tempeh processing standard quality. The purpose of this study is to obtain data on the number of coliforms contamination and the presence or absence of Salmonella sp. contamination on banana leaves-wrapped soybean tempeh from manufacturer of production 5-10 kg per day in District of Sidorejo and Tingkir, Salatiga with standar provision of SNI 3144-2015.For the detection of coliform contamination, method used Most probable Number (MPN) series of three tubes with Presumtive Test and Comfirmative Test, as well as the detection of Salmonella sp. with SSA (Salmonella Shigella Agar) specific media. The research result that average sample of manufacturers in Sidorejo and Tingkir District have not met the standard limits of coliform contamination. The highest value of coliform contamination was &gt;1100 APM/g and lowest value was 7 APM/g, while the Salmonella sp. detection in average yield positive result but found one sample showed negative result. Found one sample contaminated with Shigella sp. bacteria.High contamination of coliform and Salmonella was identified obtain from the tools and materials used in manufacturing process, lack of sanitation in manufacture environment, and so the individual as the manufacturer.</p>
APA, Harvard, Vancouver, ISO, and other styles
45

Sultan, Sitti N., Jemmy Abidjulu, and Harry S. J. Koleangan. "ANALISIS KANDUNGAN MERKURI DAN SIANIDA DI DAERAH ALIRAN SUNGAI TALAWAAN, SULAWESI UTARA." JURNAL ILMIAH SAINS 15, no. 1 (February 10, 2015): 70. http://dx.doi.org/10.35799/jis.15.1.2015.8311.

Full text
Abstract:
ABSTRAK Telah dilakukan penelitian untuk menentukan konsentrasi merkuri dan sianida di DAS Talawaan dengan metode Spektofotometer Serapan Atom Uap Dingin (CVAAS) untuk merkuri dan Spektrofotometer HACH DR 5000 untuk sianida yang kemudian dibandingkan dengan hasil penelitian sebelumnya. Pengambilan dan pengujian sampel dilakukan sebanyak dua kali dengan selisih waktu 1 bulan. Hasil penelitian menunjukkan bahwa konsentrasi merkuri dibawah batas deteksi yaitu ≤ 0,0007 ppm yang dalam penelitian sebelumnya berkisar pada 0,0013-0,0015 ppm. Sedangkan konsentrasi sianida di DAS Talawaan berkisar pada 0,001-0,01 ppm, tidak jauh berbeda dengan penelitian sebelumnya yaitu berkisar pada 0,005-0,017 ppm. Kata kunci: pencemaran, merkuri, sianida, DAS Talawaan CONTENT ANALYSIS OF MERCURY AND CYANIDE IN TALAWAAN WATERSHED, NORTH SULAWESI ABSTRACT Has conducted a study to determine the concentrations of mercury and cyanide in the Talawaan watershed with methods Cold Vapor Atomic Absorption Spectrophotometer (CVAAS) for mercury and HACH DR 5000 Spectrophotometer for cyanide which is then compared with the results of previous studies. Making and testing of samples performed twice with a gap of 1 month. The results showed that mercury concentrations below the detection limit is ≤ 0,0007 ppm in previous research revolves around 0,0013-0,0015 ppm. not much different from previous studies that range in 0,005-0,017 ppm. Keywords: pollution, mercury, cyanide, DAS Talawaan
APA, Harvard, Vancouver, ISO, and other styles
46

Arismaya, Fenly, Siswoyo Siswoyo, and Asnawati Asnawati. "OPTIMASI PARAMETER TEKNIK SQUARE WAVE VOLTAMMETRY DENGAN ELEKTRODA GRAFIT FAN PENERAPANNYA PADA ANALISIS KLORIN BEBAS DALAM AIR CUCIAN BERAS BERPEMUTIH." Jurnal Kimia Riset 3, no. 2 (March 4, 2019): 139. http://dx.doi.org/10.20473/jkr.v3i2.8704.

Full text
Abstract:
AbstrakKlorin (OCl-) merupakan bahan kimia berbahaya bagi kesehatan manusia, yang kadang digunakan sebagai bahanpemutih beras. Oleh sebab itu dilakukan upaya analisis Klorin menggunakan teknik Square Wave Voltammetry. Penelitian ini melakukan optimasi pengaturan parameter (konsentrasi larutan elektrolit, pH, dan sampling time) dan karakterisasi metode kerja dari teknik Square Wave Voltammetry, sehingga teknik ini dapat diaplikasikan untuk analisis klorin bebas (OCl-) dalam air cucian beras berpemutih. Variasi konsentrasi larutan elektrolit yang diterapkan dalam penelitian ini adalah 0,05; 0,10; 0,15; 0,20; 0,25 M. Variasi pH yang diterapkan pada pH 7, 8, 9, 10, 11, dan 12. Variasi sampling time yang diterapkan adalah 5, 10, 15, dan 20 milisekon. Berdasarkan hasil penelitian yang diperoleh, konsentrasi larutan elektrolit optimum pada konsentrasi 0,15 M, pH optimum pada kondisi pH 9, dan sampling time optimum adalah 10 milisekon. Hasil karakterisasi kinerja metode pada teknik Square Wave Voltammetry yang telah dioptimasi ini menghasilkan linieritas 0,9885, limit deteksi sebesar 9,563 ppm, dan nilai koefisien variasi sebesar 4,09%. Hasil pengukuran konsentrasi klorin bebas (OCl-) dengan teknik Square Wave Voltammetry yang telah dioptimasi adalah senilai 30,125 ppm. Pengaturan tiga parameter tersebut berpengaruh terhadap bentuk dan ketinggian puncak voltamogram yang dihasilkan. Kata Kunci: Square Wave Voltammetry, Optimasi Parameter, Klorin bebas, Beras Berpemutih.
APA, Harvard, Vancouver, ISO, and other styles
47

Asra, Ridho, Rusdi Rusdi, Sofia Nofianti, and Nessa Nessa. "Perbandingan Akrilamidakopi Bubuk Tradisional Dan Luwak Dengan Metode HPLC." Jurnal Katalisator 4, no. 2 (October 31, 2019): 61. http://dx.doi.org/10.22216/jk.v4i2.4644.

Full text
Abstract:
<p><em>Akrilamida merupakan senyawa kimia terdapat pada kopi yang disangrai pada suhu diatas 120 ˚C, berpotensi menyebabkan kanker pada manusia. Tujuan dari penelitian ini adalah untuk membandingkan kandungan akrilamida dalam kopi bubuk tradisional dan kopi luwak dengan metode Kromatografi Cair Kinerja Tinggi. Fase gerak yang digunakan asetonitril: aquabidest (15: 85, v/v), dengan detektor Photodioday-Array (PDA) pada ℷ 200 nm. Akrilamida dalam sampel kopi bubuk teridentifikasi pada waktu retensi (tR) ± 6,8 menit. Metode ini terbukti valid dengan linearitas y = 356468 + 293761 x, koefisien korelasi (r) = 0,9993, batas deteksi 1,9901 µg/mL dan batas kuantitasi 6,6337 µg/mL, presisi dengan % SBR = 0,207 %, akurasi dengan % perolehan kembali kopi bubuk tradisional dan kopi bubuk luwak 99 % dan 104 %. Kadar akrilamida dalam sampel kopi bubuk 1 sampai 6 berturut-turut adalah 1115 ± 12,17 µg/g sampel (1), 687 ± 7,58 µg/g sampel (2), 1461 ± 63,89 µg/g sampel (3), 221 ± 3,54 µg/g sampel (4), 128 ± 3,24 µg/g sampel (5), 195 ± 1 µg/g sampel (6). Dari keenam sampel kopi bubuk menunjukkan bahwa kadar akrilamida masing-masing sampel berkisar antara 128 sampai 1461 µg/g. Kadar yang diperoleh melebihi batas aman konsumsi akrilamida yang dikeluarkan oleh WHO</em></p><p><em><br /></em></p><p><em><em>Acrylamide is a chemical compound found in roasted coffee at temperatures above 120 ˚C which can potentially cause cancer in humans. The purpose of this research was to analyze acrylamide contents in traditional ground coffee and civet ground coffee by using High Performance Liquid Chromatography (HPLC) method. This analysis was carried out by isocratic elution system, the mobile phase of acetonitrile : aquabidest (15 : 85, v/v), using the stationary phase of the Shimadzu Shimpack ODS C18 column (250 × 4.6 mm), flow rate of 0.5 mL/minute, injection volume 20 µL, with a Photodioday-Array (PDA) detector at a wavelength of 200 nm. Acrylamide in ground coffee samples was identified at retention time (tR) ± 6.8 minutes. This method is proved valid with the linearity y = 356468 + 293761 x, correlation coefficient (r) = 0.9993, limit of detection 1.9901 µg / mL and limit of quantitation 6.6337 µg / mL, precision with % RSD = 0.207 %, acuracy with % recovery of traditional ground coffee and luwak ground coffee 99 % and 104 %. Acrylamide levels in 1 to 6 ground coffee samples in a row is 1115 ± 12.17 µg / g samples (1), 687 ± 7.58 µg / g samples (2), 1461 ± 63.89 µg / g samples (3), 221 ± 3.54 µg / g sample (4), 128 ± 3.24 µg / g sample (5), 195 ± 1 µg / g sample (6). Of the six ground coffee samples showed that the acrylamide levels of each sample ranged from 128 to 1461 µg / g. The levels obtained exceed the safe limits of acrylamide consumption released by WHO</em></em></p>
APA, Harvard, Vancouver, ISO, and other styles
48

Ni'mah, Durrotun, Muhammad Zainul Fadli, and Rio Risandiansyah. "Perbandingan Kuantitas dan Kualitas DNA Bacillus sp. antara Heat Treatment dan Filter berbasis Kit." BIOSAINTROPIS (BIOSCIENCE-TROPIC) 6, no. 2 (January 25, 2021): 86–95. http://dx.doi.org/10.33474/e-jbst.v6i2.383.

Full text
Abstract:
Diagnosis of bacterial infection can be done quickly with simplified DNA isolation methods, such as Heat Treatment, which is a simple and inexpensive DNA isolation method, but detection and quantification levels of Bacillus sp. still unknown. This study aims to compare the quantity and quality of DNA isolates from Bacillus sp. using Heat Treatment etraction method and Filter Based isolation method. This research used in vitro experiment method. Heat Treatment is compared to Filter Based Kit according to Limit of Detection (LoD) and Limit of Quantification (LoQ). Data analyzed with ANOVA and Honesty Significant Difference (HSD). DNA yield obtained by Heat Treatment at the highest concentration was 5 µg/ml, whereas Filter Based Kit was 3.67 µg/ml. LoD of the Heat treatment and Filter Based Kit were 1.61 and 5.72 µg/ml, while LoQ of the Heat treatment and Filter Based Kit were 4.87 and 17.34 µg/ml. The number of bacteria that exceeded the LoD and LoQ of Heat Treatment was 101 and 104 CFU/ml, whereas the LoD and LoQ of Filter Based Kit was >104 CFU/ml. The quantitiy of Bacillus sp. DNA with Heat Treatment method is better than Filter Based Kit. The quality of Bacillus sp. DNA both the Heat Treatment and Filter Based Kit methods are not good. Keywords: DNA isolation, Bacillus sp., heat treatment, Filter Based Kit ABSTRAK Penegakkan diagnosis infeksi bakteri dapat dilakukan secara cepat dengan metode isolasi DNA yang telah disederhanakan, seperti Heat Treatment yang merupakan metode ekstraksi DNA sederhana dan ekonomis, namun tingkat deteksi dan kuantifikasi terhadap Bacillus sp. masih belum diketahui. Penelitian ini bertujuan membandingkan kuantitas dan kualitas DNA dari Bacillus sp. dengan menggunakan metode ekstraksi Heat Treatment dan metode isolasi Filter Based Kit. Penelitian ini menggunakan metode penelitian eksperimen secara in vitro. Heat Treatment dibandingkan dengan Filter Based Kit berdasarkan Limit of Detection (LoD) and Limit of Quantification (LoQ). Analisa data menggunakan uji ANOVA serta uji Honesty Significant Diference (HSD). Yield DNA yang didapatkan Heat Treatment pada konsentrasi terbesar adalah 5 µg/ml, sedangkan dengan Filter Based Kit adalah 3.67 µg/ml. Nilai LoD Heat treatment dan Filter Based Kit adalah 1.61 µg/ml dan 5.72 µg/ml, sedangkan nilai LoQ Heat treatment dan Filter Based Kit adalah 4.87 µg/ml dan 17.34 µg/ml. Jumlah bakteri yang melebihi nilai LoD dan LoQ Heat treatment adalah 101 CFU/ml dan 104 CFU/ml, sementara LoD dan LoQ Filter Based Kit adalah >104 CFU/ml. Kuantitas DNA Bacillus sp. dengan metode Heat Treatment lebih baik dibandingkan dengan Filter Based Kit. Kualitas DNA Bacillus sp. baik dengan metode Heat Treatment maupun Filter Based Kit tidak baik. Kata kunci: isolasi DNA, Bacillus sp., heat treatment, Filter Based Kit
APA, Harvard, Vancouver, ISO, and other styles
49

Taufik, Moh, Seveline Seveline, and Emilia Ratih Saputri. "Validasi Metode Analisis Kadar Kalsium pada Susu Segar secara Titrasi Kompleksometri." Agritech 38, no. 2 (July 30, 2018): 187. http://dx.doi.org/10.22146/agritech.25459.

Full text
Abstract:
Analysis of calcium content in fresh milk generally uses Atomic Absorption Spectroscopy (AAS). Alternatively, it could be analyzed using complexometric titration. The study aimed to validate the method of calcium content analysis in fresh milk by complexometric titration. The results showed that the linearity test using calcium standard solution at a working range of 4-24 mg/100 mL had R2 of 0.9983, while the limit of detection and limit of quantification were 0.47 mg/100 mL and 1.57 mg/100 mL, respectively. The accuracy by spiking method at the spiking concentration of 60 mg/100 mL sample was 99.29%. The repeatability and intra-lab reproducibility showed acceptable precision with CV value of 0.98% and 2.59%, respectively. The results of ruggedness test showed that this method was rugged to the variation of sample volume and ethylenediaminetetraacetic acid (EDTA) concentration. This study proved that complexometric titration can be used to determine calcium content in fresh milk. ABSTRAKAnalisis kadar kalsium pada susu segar umumnya menggunakan Atomic Absorption Spectroscopy (AAS) yang relatif mahal. Salah satu metode alternatif yang dapat digunakan adalah titrasi kompleksometri. Sampai sekarang, data validasi terhadap metode tersebut pada sampel susu segar belum tersedia. Tujuan penelitian ini adalah memvalidasi metode analisis kadar kalsium pada susu segar secara titrasi kompleksometri. Hasil penelitian menunjukkan uji linearitas dengan menggunakan larutan standar kalsium pada rentang 4-24 mg/100 mL mempunyai nilai R2 sebesar 0,9983, sedangkan nilai batas deteksi dan batas kuantifikasi berturut-turut adalah 0,47 mg/100 mL dan 1,57 mg/100 mL. Nilai akurasi (recovery) sebesar 99,29% pada konsentrasi spiking 60 mg/100 mL sampel. Hasil penelitian atau metode uji yang divalidasi menunjukkan nilai keterulangan dan reprodusibilitas intralab yang baik dengan nilai CV analisis berturut-turut 0,98% dan 2,59%. Hasil uji ketangguhan menunjukkan metode ini bersifat tangguh (rugged) terhadap variasi volume sampel dan konsentrasi asam etilenadiaminatetraasetat (EDTA) yang digunakan. Berdasarkan hasil penelitian tersebut, metode titrasi kompleksometri dapat digunakan untuk menentukan kadar kalsium pada susu segar.
APA, Harvard, Vancouver, ISO, and other styles
50

Retnaningtyas, Yuni, Lestyo Wulandiri, and Gabriella F. Punu. "DEVELOPMENT AND VALIDATION OF A TLC DENSITOMETRIC METHOD FOR DETERMINATION OF GLIMEPIRIDE IN TABLETS." Jurnal Kimia Terapan Indonesia 16, no. 1 (June 10, 2014): 11–15. http://dx.doi.org/10.14203/jkti.v16i1.3.

Full text
Abstract:
A simple and valid TLC method has been developed for the determination of glimepiride in tablet formulation. After extraction of the analyte with a mixture of methanol and ammonia 0,2M (1:1, v/v), the extracts were spotted on precoated TLC silica gel F254 plates, which were developed with a mixture of toluene:methanol:ethyl acetate (75:20:5, v/v/v). Quantitative evaluation was performed by measuring the absorbance reflectance of the analyte spots at 238 nm. The method was validated for specificity, linearity, accuracy and precision. Good linearity was achieved in the concentration range 100–800 ng/spot. The RSD of repeatability and intermediate precision were found to be less than 2%, whereas the mean of the recovery data was 100-101%. The detection limit and quantification limit were 22 and 74 ng/spot, respectively. The method is specific, linear, precise, and accurate; it can be used for the routine quality control testing of marketed formulations.Keywords: glimepiride, TLC densitometric, validation of pharmaceutical methods, pharmaceutical analysis, antidiabetic drug Sebuah metode Kromatografi Lapis Tipis (KLT) yang sederhana dan valid telah dikembangkan untuk penentuan glimepiride dalam sediaan tablet. Setelah analit dalam sampel diekstraksi dengan campuran metanol dan amonia 0,2 M (1:1,v/v), ekstrak yang terlihat pada lempeng silika gel F254, yang dikembangkan dengan campuran toluen : metanol : etil asetat (75:20:5, v/v/v). Evaluasi kuantitatif dilakukan dengan mengukur reflektansi absorbansi noda analit pada panjang gelombang 238 nm.Metode ini divalidasi meliputi spesifisitas, linearitas, akurasi dan presisi.Linearitas yang baik dicapai pada rentang konsentrasi 100-800 ng / spot. RSD pengulangan dan presisi intermediate menunjukkan nilai kurang dari 2 %, sedangkan rata-rata data recovery adalah 100-101 % .Batas deteksi dan batas kuantifikasi adalah 22 dan 74 ng / noda.Metode ini spesifik, linear, tepat, dan akurat, bisa digunakan untuk pengujian kontrol kualitas rutin tablet glimepirid dipasarkan. Kata Kunci: glimepiride, TLC densitometric, validation of pharmaceutical methods, pharmaceutical analysis, antidiabetic drug
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography