To see the other types of publications on this topic, follow the link: Loop recorder.

Dissertations / Theses on the topic 'Loop recorder'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 44 dissertations / theses for your research on the topic 'Loop recorder.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

Goulkhah, Mohammad (Monty). "Waveform relaxation based hardware-in-the-loop simulation." Cigre Canada, 2014. http://hdl.handle.net/1993/31012.

Full text
Abstract:
This thesis introduces an alternative potentially low cost solution for hardware-in-the-loop (HIL) simulation based on the waveform relaxation (WR) method. The WR tech-nique is extended so that, without the need for a real-time simulator, the behaviour of an actual piece of physical hardware can nevertheless be tested as though it were connected to a large external electrical network. This is achieved by simulating the external network on an off-line electromagnetic transients (EMT) simulation program, and utilizing iterative exchange of waveforms between the simulation and the hardware by means of a spe-cialized Real-Time Player/Recorder (RTPR) interface device. The approach is referred to as waveform relaxation based hardware-in-the-loop (WR-HIL) simulation. To make the method possible, the thesis introduces several new innovations for stabi-lizing and accelerating the WR-HIL algorithm. It is shown that the classical WR shows poor or no convergence when at least one of the subsystems is an actual device. The noise and analog-digital converters’ quantization errors and other hardware disturbances can affect the waveforms and cause the WR to diverge. Therefore, the application of the WR method in performing HIL simulation is not straightforward and the classical WR need to be modified accordingly. Three convergence techniques are proposed to improve the WR-HIL simulation con-vergence. Each technique is evaluated by an experimental example. The stability of the WR-HIL simulation is studied and a stabilization technique is proposed to provide suffi-cient conditions for the simulation stability. The approach is also extended to include the optimization of the parameters of power system controllers located in geographically distant places. The WR-HIL simulation technique is presented with several examples. At the end of the thesis, suggestions for the future work are presented.
February 2016
APA, Harvard, Vancouver, ISO, and other styles
2

Pounds, Gareth Lee. "REveAL™ and CARElink™ (Real Care) : minimising the time taken to achieve a diagnosis in the implantable loop recorder population." Thesis, Durham University, 2017. http://etheses.dur.ac.uk/12170/.

Full text
Abstract:
Introduction Syncope accounts for ≈ 2.7/1000 population/year of presentations to UK healthcare, a figure believed to be underestimated by up to 30% due to misdiagnosis. For some patients the cause of their episode/s may remain unexplained. The implantable loop recorder (ILR) is effective for diagnosis of syncope and palpitations, with UK and European guidelines advising its use if symptoms are infrequent. However current follow-up regimes can lead to a slow diagnostic pathway for patients. Remote monitoring technology allows patients to send their ILR data to their clinic Research Questions 1) Does remote monitoring of ILRs reduce time to diagnosis and/or increase diagnostic yield? 2) What is the impact of remote monitoring on logged events requiring analysis? Method New ILR patients at a single implanting centre were recruited. Following informed consent, they were randomised into control or experimental groups. Patients in the control group were reviewed in the conventional manner with routine 6 monthly follow-ups plus additional ad hoc checks if symptoms occurred. Patients in the experimental group were asked to send transmissions fortnightly or following a symptom. All recordings were reviewed and classified as true or false events according to pre-defined criteria. Significant true event ECGs were reviewed blindly by a cardiologist. All data were verified by two physiologists or a physiologist and a cardiologist prior to analysis. The primary outcome variable was median time to clinical diagnosis. Results 37 patients were randomised, 19 to the control and 18 to the experimental group. The control group comprised 11 males and 8 females with a median age of 60 (36-86) years. The experimental group comprised 10 males and 8 females, median age 58 (36-84) years. Mann-Whitney U testing showed no significant differences in group demographics. Following randomisation 5526 events were logged, 1264 in the control and 4262 in the experimental group. 28 (76%) of patients had a true event, which led to a diagnosis in 23 (67%) of patients. There were 13 patients with true events and 10 diagnoses in the experimental group, with 15 true events and 13 diagnoses in the control group. Asystole was the most common event that led to a diagnosis, accounting for 35% of diagnoses. Kaplan-Meier analysis was used to assess the primary outcomes of time from event to follow-up, and time to clinical diagnosis. Compared to the control group, the median time from event to follow-up was reduced from 3 to 1 week (p=0.004). Median time to diagnosis was reduced from 13 to 6 weeks (p=0.049) when remote monitoring was used. Conclusion In patients with ILR, remote monitoring significantly reduced diagnostic delay although the overall diagnostic yield was not increased. However remote monitoring resulted in a three-fold increase in logged events that required analysis with only 1 in 328 proving to be true events: this will have significant resource implications.
APA, Harvard, Vancouver, ISO, and other styles
3

Hait, Jan Joseph [Verfasser], and Peter [Gutachter] Nordbeck. "Prophylaktische Loop-Recorder Implantation zur Detektion kardialer Rhythmusstörungen bei Patienten mit Fabry-Kardiomyopathie: 2-Jahres-Follow-Up / Jan Joseph Hait ; Gutachter: Peter Nordbeck." Würzburg : Universität Würzburg, 2020. http://d-nb.info/1209881306/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Kreuzhuber, Manuela. "Erste klinische Erfahrung mit einem implantierbaren kardialen Monitor zur Detektion von Vorhofflimmern." Doctoral thesis, Universitätsbibliothek Leipzig, 2014. http://nbn-resolving.de/urn:nbn:de:bsz:15-qucosa-131103.

Full text
Abstract:
EINLEITUNG Vorhofflimmern und orale Antikoagulation Vorhofflimmern stellt ein Grundproblem der modernen Gesellschaft dar und fordert zunehmend den Einsatz medizinischer Ressourcen. Es ist die Folge eines komplexen Prozesses aus Triggern, elektrophysiologischen und später auch strukturellen Umbauprozessen im Vorhofmyokard. Man unterscheidet paroxysmales von persistierenden und permanenten Vorhofflimmern. Zusätzlich muss man symptomatische Episoden von asymptomatischen trennen, wobei der Anteil letzterer mit bis zu 70% beschrieben wird. Asymptomatisches Vorhofflimmern wird als eine häufige Ursache eines kryptogenen Schlaganfalls vermutet. Bislang konnte gezeigt werden, dass längere Überwachungszeiträume des Herzrhythmus häufiger Vorhofflimmern bei dieser Patientengruppe erfassen können. Somit hat hier der Nachweis von Vorhofflimmern einen entscheidenden Einfluss auf die Therapie durch entsprechende Senkung des thrombembolischen Risikos. Bei Patienten mit bekanntem Vorhofflimmern dagegen besteht die Gefahr einen Therapieerfolg aufgrund asymptomatischer Episoden zu überschätzen und die Vorhofflimmerlast, den sogenannten AF Burden zu unterschätzen. Entsprechend waren und sind mit dem subjektiven Therapieerfolg medizinische Entscheidungen verbunden, welche in Bezug auf das Auftreten thrombembolischer Ereignisse eine gewisse Rolle spielen. Statistisch gesehen wird das thrombembolische Risiko nach dem CHADS2 oder CHA2DS2 VASc Score berechnet und danach zwischen einer Plättchenhemmung, einer oralen Antikoagulation, direkten Thrombin-, Faktor Xa Inhibitoren oder keiner weiteren Therapie entschieden. Patienten mit Vorhofflimmern können auf zwei Arten behandelt werden. Bei der sogenannten Frequenzkontrolle erfolgt kein direkter Angriff auf die Rhythmusstörung, nur auf die Geschwindigkeit der Herzfrequenz und deren Symptome. Demgegenüber steht die Rhythmuskontrolle mit vordergründigem Erhalt des Sinusrhythmus, sowohl elektrisch, als auch medikamentös oder interventionell. Die Erfassung des Herzrhythmus und der implantierbare kardiale Monitor Ob ein Sinusrhythmus oder Vorhofflimmern vorliegt kann nur anhand eines EKGs geklärt werden. Zur Überwachung eines längeren Zeitraums kommen sogenannte Holter-EKGs mit einer Aufzeichnungsdauer von mindestens 24 Stunden, maximal 7 Tagen in Frage. Aufgrund von seltenen, wahrscheinlich rhythmogen bedingten Symptomen wie zum Beispiel Synkopen, wurde eine Weiterentwicklung mit noch längeren Aufzeichnungskapazitäten notwendig. Dem externen Event- und Loop-Recorder folgte der implantierbare kardiale Monitor. Der Reveal XT 9529 (Medtronic Inc, Minneapolis), ein implantierbarer kardialen Monitor mit einem speziellen Detektionsalgorithmus für Vorhofflimmern ist dabei Gegenstand dieser Untersuchung. ZIEL DER ARBEIT Evaluierung des REVEAL XT 9529 (Medtronic Inc, Minneapolis) bei einer Patientenpopulation mit Vorhofflimmern im klinischen Alltag. METHODEN Der automatische Detektion von Vorhofflimmern durch einen implantierten kardialen Monitor unterliegt eine Analyse des R-Zacken Abstandes innerhalb von zwei Minuten. Kommt es hier zu Unregelmäßigen erfolgt automatisch eine Einordnung des Herzrhythmus in den Bereich Vorhofflimmern (AF). Die Episoden können in der Regel manuell mit einem Frequenzplot und einer EKG-Ableitung (EGM) überprüft werden. Analysiert wurde eine Gruppe von 92 Patienten, welche vorrangig an Vorhofflimmern litten. Zusätzliche Daten wie Alter, Geschlecht, linksventrikuläre Pumpfunktion, kardiale Begleiterkrankungen und medikamentöse Therapie wurden ebenfalls erfasst. 88% der mit dem implantierbaren kardialen Monitor versorgten Patienten wurden aufgrund des Vorhofflimmerns vorbehandelt, bei 82% stand ein neuerlicher Therapieversuch bevor. Die Implantation des kardialen Monitors fand unter sterilen Operationsbedingungen statt, nachfolgend wurden die Patienten in die Funktion eingewiesen. Die Termine zur Nachsorge wurden im Rahmen der klinischen Routine vergeben und umfassten eine Überprüfung und Wertung der automatisch detektierten Rhythmusereignisse. Bei einer Untergruppe von 62 Patienten erfolgte parallel die Anlage von 7 Tage Langzeit-EKGs und eine Wertung der Ergebnisse im Vergleich. Die statistische Datenanalyse erfolgte mit Microsoft Office Excel 2007 und SPSS, Version 11.5.1. Mittelwerte werden mit Standardabweichung angegeben, im Falle des Medians zusätzlich Minimum und Maximum. Prozentuelle Angaben erfolgen bei Zahlen. Für statistisch abhängige Stichproben erfolgte die Anwendung des McNemar Tests, für unabhängige Werte der Chi-Quadrat Test. Es gilt das allgemein übliche Signifikanzniveau von p < 0,05. ERGEBNISSE Die Ergebnisse der manuellen Überprüfung wurden in folgende Kategorien eingeteilt: 1. Kein Vorhofflimmern unter Einsicht sämtlicher EGMs. 2. Sicheres Vorhofflimmern mit eindeutigem Nachweis in den gespeicherten EGMs. 3. Mögliches Vorhofflimmern, aber ohne diagnostische Sicherheit, da ein EGM nicht vorliegt. Davon ausgehend erfolgte die weitere Unterteilung in: - Regelrechten Sinusrhythmus ohne Nachweis von Artefakten. - Regelrechten Sinusrhythmus, aber Aufzeichnung von Artefakten im Sinne einer Fehlklassifikation. - Regelrechten Nachweis von Vorhofflimmern und Fehlklassifikation von Sinusrhythmus bei Artefakten. - Fehlklassifikation von Sinusrhythmus bei Artefakten, zusätzlich diagnostische Unsicherheit ob Vorhofflimmern aufgetreten ist, da nicht alle EGMs einsehbar. Vor dem Softwareupgrade wurden 287 Abfragen von 92 Patienten analysiert. Im Durchschnitt wurden 1078 (± 4851) Episoden registriert, im Median lag diese Zahl bei 58 (0 – 67099). Bezogen auf das Auftreten von Vorhofflimmern blieben 55 (19%) der Abfragen ohne Episoden. Ein komplett einsehbarer EGM Speicher war bei 140 (49%) der Abfragen zu finden, bei 147 (51%) waren dagegen EGMs schon wieder überschrieben und damit nicht mehr überprüfbar. Unter diesen Patienten zeigten 53 (19%) reines Vorhofflimmern im Speicher, 21 (7%) Vorhofflimmern mit Artefakten und weitere 73 (25%) nur Sinusrhythmus mit Artefakten. Gerade bei dieser letzten Gruppe kann keine sichere Aussage über das reelle Auftreten oder Fehlen von Vorhofflimmern gemacht werden. Auf sämtliche Abfragen vor dem Softwareupgrade gesehen waren Muskelpotentiale, welche bei 134 (47%) von 287 Abfragen auftraten das Hauptproblem unter den Artefakten und Ursache für die automatische Fehlklassifikation. Weitere Fehlklassifikationen betrafen Undersensing, die Einordnung von Vorhofflimmern in den Bereich einer ventrikulären Tachykardie, ventrikuläre und supraventrikuläre Extrasystolen, den AT-Algorithmus und T-Wave Oversensing. In den verbleibenden 65 Patienten nach dem Softwareupgrade wurden 116 analysierbare Abfragen erhoben. Bezogen auf das Auftreten von Vorhofflimmern blieben 41 (35%) der Abfragen ohne Episoden. Ein komplett einsehbarer EGM Speicher war bei 78 (67%) der Abfragen zu finden. Unter den Patienten mit bereits überschriebenen EGM zeigten 17 (15%) reines Vorhofflimmern im Speicher, 9 (8%) Vorhofflimmern mit Artefakten und weitere 12 (10%) nur Sinusrhythmus mit Artefakten. Ein direkter Vergleich der Ergebnisse zeigte eine signifikante Reduktion der beschriebenen Fehlklassifikation von Vorhofflimmern aufgrund von Myopotentialen, Undersensing und des AT-Algorithmus. Für 62 der Patienten liegen im Mittel 502 (± 156), im Median 508 (51 – 677) Stunden an Langzeit-EKG Aufzeichnung vor. Vorhofflimmern kann 48% im Langzeit-EKG registriert werden, im Reveal XT 9529 (Medtronic Inc, Minneapolis) nach manueller Überprüfung der Episoden dagegen bei 81%. Das Signifikanzniveau liegt bei p < 0,001. DISKUSSION Nach den vorliegenden Ergebnissen dieser Arbeit zeigt sich, dass die grundlegende Forderung nach einer kontinuierlichen EKG-Überwachung nur eingeschränkt mit dem Reveal XT 9529 (Medtronic Inc, Minneapolis) zu erreichen ist. Es traten zahlreiche Probleme mit Artefakten durch das beschriebene Oversensing und aufgrund der Speicherkapazität auf. Lösungsansätze sind hier die stärkere Einbeziehung des “Patient Assistant“ beziehungsweise ein Remote-Follow-Up. Bereits initiiert wurde ein Softwareupgrade welches durch Ausweitung des “Noise“ die Artefaktanfälligkeit deutlich senken konnte. Zusätzlich stehen die direkte Anpassung der Programmierung und die Anpassung der Sensitivität zur Verfügung. Diskutiert werden sollte weiterhin eine Veränderung des Erkennungsalgorithmus mit 2-dimensionaler Auswertung der RR-Intervalle und der RR-Differenz. Zusätzlich muss der Einfluss des Patienten auf die Handhabung des Systems im Blick behalten werden. Grundsätzlich sind zum einen das technische Verständnis, zum anderen die Compliance, welche durch verschiedene Faktoren geprägt wird. Der Einfluss eines kontinuierlichen EKG-Monitorings auf das Management der oralen Antikoagulation und Rezidive von Vorhofflimmern birgt ein enormes Potential wie Daten bei Schrittmacher- und ICD-Patienten zeigen. Trotzdem sind hier viele wichtige Studien zum aktuellen Zeitpunkt ausstehend. Festzuhalten bleibt, dass Studien im allgemeinen und speziellen durch den Einsatz eines implantierbaren kardialen Monitors effektiver gestaltet, Rezidive der Rhythmusstörung sicherer erfasst werden würden und auch eine Anpassung der oralen Antikoagulation denkbar ist. Weiterhin wären im Bereich des kryptogenen Schlaganfalls höhere Aufklärungsraten anzunehmen. Im Vergleich mit einem 7 Tage Langzeit-EKG zeigt ein implantierbarer kardialer Monitor eine vermehrte Erfassung von Vorhofflimmern trotz der beschriebenen Probleme. Zu diskutieren bleiben die Invasivität des Verfahrens und die endgültigen Kosten. LIMITATIONEN Das vorgestellte Patientenkollektiv wurde nicht prospektiv untersucht, sondern im Rahmen einer Observationsstudie retrospektiv analysiert. Zusätzlich handelt es sich um eine selektionierte Gruppe von Patienten, zumeist mit dem Ziel einer invasiven Ablationsbehandlung und dadurch vorgegeben, einigen Besonderheiten. Zu beachten ist außerdem, dass einzig die Problematik in Bezug auf Vorhofflimmern untersucht, andere messbare Rhythmusstörungen im Rahmen dieser Analyse ausgeschlossen wurden. AUSBLICK Vorhofflimmern und seine Therapie wird ein relevanter Faktor in der Zukunft vieler betroffener Patienten bleiben, die Forderung nach einer kontinuierlichen EKG-Überwachung für verlässliche Aussagen sich entsprechend verstärken. Die erste Generation der implantierbaren kardialen Monitore stellt einen vielversprechenden Anfang dar. Weitere Entwicklungen mit Verbesserung der Artefaktanfälligkeit und Speicherkapazität, sowie der Telemedizin sind notwendig. Gerade mit Blick auf asymptomatisches Vorhofflimmern sind viele Fragen offen und können nur mit einer lückenlosen, sensitiven und spezifischen EKG-Dokumentation beantwortet werden.
APA, Harvard, Vancouver, ISO, and other styles
5

Marcosano, Irene Marialuisa. "le tecnologie emergenti per il trattamento della cardiomiopatia aritmogena." Bachelor's thesis, Alma Mater Studiorum - Università di Bologna, 2020.

Find full text
Abstract:
Arrhythmogenic cardiomyopathy is a progressive genetic disease of the myocardium characterized by myocardial atrophy and fibro-fatty replacement of the ventricular myocardium. It has familial recurrence in about 50% of cases with an autosomal dominant mode of inheritance, with incomplete penetrance and with great phenotypic variability. It is considered one of the main causes of sudden cardiac death (SCD) in young people and athletes. Diagnosis is based on the 2010 Task Force criteria and includes genetic analysis and investigation of characteristic morpho-functional anomalies through electrocardiogram, echocardiography, magnetic resonance, endomyocardial biopsy and voltage mapping. An instrumental evaluation is made. Therapy starts with the stratification of the arrhythmic risk that guides the decision of the ICD implant. Thanks to the 2015 Task Force and a recent predictive model, this decision can be calibrated. Catheter ablation is one alternative for the treatment of ARVC patients who have ventricular tachycardias, but it is not a curative technique as it does not reduce the risk of sudden death. Genetic therapy and heart transplantation are developing approaches thanks to the biomedical research on stamina cells and the "genetic scissors". 3D printing can be used for scaffolds in bioartificial hearts and it offers the possibility to visualize physical models of the patient's heart. Desease preventing progression by monitoring is more and more comfortable and effective thanks to telemedicine. The cascade screening of family members through cardiac evaluation includes ECG, Holter and echocardiography or MRI exams every 2-3 years. In particular cases, a subcutaneous loop recorder can be implanted. The aim of this thesis is to present emerging technologies to support disease treatment, in order to offer useful updates for optimal management and to improve the patient's quality of life.
APA, Harvard, Vancouver, ISO, and other styles
6

Oesterle, Ulf. "Organizational influence on recorded music a look at the independents /." Related electronic resource:, 2007. http://proquest.umi.com/pqdweb?did=1354131191&sid=1&Fmt=2&clientId=3739&RQT=309&VName=PQD.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Yung, Weng Hong. "Analysis of loop execution in workflows." Thesis, University of Macau, 2017. http://umaclib3.umac.mo/record=b3691455.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Adu, Ebenezer Siaw. "Organizational Complexity and Hospitals' Adoption of Electronic Medical Records for Closed-loop Medication Therapy Management." ScholarWorks, 2017. https://scholarworks.waldenu.edu/dissertations/3652.

Full text
Abstract:
Over 700,000 adverse drug events (ADEs) result in emergency hospital visits annually, and many of these ADEs are preventable through the use of health information technology in hospitals. However, only 12.6% of U.S. hospitals have developed the capacity to adopt closed-loop electronic medical records (EMR). Organizational complexity may be a major factor influencing hospitals' adoption of closed-loop EMR. This quantitative study explored how organizational complexity influenced hospitals' adoption of closed-loop EMR. Diffusion of innovation theory was the foundation for this study. Logistic regression was used to establish possible relationships between organizational complexity and hospitals' adoption of EMR for closed-loop medication therapy management. Secondary data from Health Information and Management Systems Society were examined to explore the relationship between organization complexity and hospitals' adoption of EMR for closed-loop medication therapy. The research questions explored whether vendor selection strategy, structural complexity, and management structure influence hospitals' adoption of EMR for closed-loop medication therapy management. The results indicated that all three variables, vendor selection strategy, structural complexity, and management structure, are statistically significant predictors of hospitals' adoption of EMR for closed-loop medication therapy management. Results from this study may promote positive social change by enhancing hospitals' adoption of EMR for closed-loop medication therapy management, which may therefore help improve the quality, efficiency, and safety of health care delivery in U.S. hospitals.
APA, Harvard, Vancouver, ISO, and other styles
9

Kwan, Hing-kit. "Design algorithms for delta-sigma modulator loop filter topologies." Click to view the E-thesis via HKUTO, 2008. http://sunzi.lib.hku.hk/hkuto/record/B4150883X.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Mak, Peng Kin. "Mixed Mode Phase Locked Loop macromodeling and simulation with PSPICE." Thesis, University of Macau, 1998. http://umaclib3.umac.mo/record=b1445569.

Full text
APA, Harvard, Vancouver, ISO, and other styles
11

Kwok, Wai-kei. "Oncogenic function of TWIST in the development and progression of prostate cancer." Click to view the E-thesis via HKUTO, 2007. http://sunzi.lib.hku.hk/hkuto/record/B3893825X.

Full text
APA, Harvard, Vancouver, ISO, and other styles
12

Cheang, Sek Un. "Robust control system design : H∞ loop shaping for double inverted pendulum." Thesis, University of Macau, 2002. http://umaclib3.umac.mo/record=b1445662.

Full text
APA, Harvard, Vancouver, ISO, and other styles
13

Wu, Wei. "Research on loop flow problem and its solutions in Macau power system." Thesis, University of Macau, 2003. http://umaclib3.umac.mo/record=b1807202.

Full text
APA, Harvard, Vancouver, ISO, and other styles
14

Yuen, Hiu-fung. "Roles of twist in prostate cancer progression." Click to view the E-thesis via HKUTO, 2007. http://sunzi.lib.hku.hk/HKUTO/record/B39558319.

Full text
APA, Harvard, Vancouver, ISO, and other styles
15

Lu, Ting Shan. "A microstrip square-loop dual-mode balun-bandpass filter with simultaneous size reduction and spurious response suppression." Thesis, University of Macau, 2009. http://umaclib3.umac.mo/record=b2129882.

Full text
APA, Harvard, Vancouver, ISO, and other styles
16

Matook, Elaina. "A Look in the Mirror - Daring to Face the Truth about Malaria." Thesis, Boston College, 2007. http://hdl.handle.net/2345/503.

Full text
Abstract:
Thesis advisor: Susan A. Michalczyk
Malaria is a curable, preventable disease which has been around for millennia. Unfortunately, in this time of unprecedented growth and resources, the world has yet to prevent malaria from continuing its vicious cycle, taking the life of a child every thirty seconds. This project is an interdisciplinary creative writing exploration of the underlying biological, sociological, and theological reasons for this failure to eradicate an avoidable illness. Aside from the biological difficulties involved in creating vaccines for the complex strains of the malaria parasite, the deeper cause of malaria's persistence within the bloodstream of humanity is the narcissism to which all people are prone, especially when self-interest is upheld as the highest virtue of Western capitalistic society. Literature, sociology, and theology, among other fields, each point to the answer of humility and love as solutions to the global problem caused by the fact that, ultimately, there is something far worse than malaria plaguing everyone from within
Thesis (BA) — Boston College, 2007
Submitted to: Boston College. College of Arts and Sciences
Discipline: College Honors Program
APA, Harvard, Vancouver, ISO, and other styles
17

Iao, In Mei. "How MBA graduates and local employers look at MBA." Thesis, University of Macau, 2004. http://umaclib3.umac.mo/record=b1636721.

Full text
APA, Harvard, Vancouver, ISO, and other styles
18

Zhang, Xiaomeng. "Significance and molecular basis of Id-1 in regulation of cancer cell survival and invasion." Click to view the E-thesis via HKUTO, 2007. http://sunzi.lib.hku.hk/hkuto/record/B39325477.

Full text
APA, Harvard, Vancouver, ISO, and other styles
19

Yonge, Mark Duke. "The Klebanov Polyakov correspondence on a squashed three sphere and Wilson loops in non relativistic AdS/CFT." Thesis, Swansea University, 2010. https://cronfa.swan.ac.uk/Record/cronfa42415.

Full text
Abstract:
Motivated by the Klebanov-Polyakov conjecture we investigate the O(N) vector model at large N on a squashed three-sphere and its holographic relation to bulk gravity on asymptotically locally AdS4 space. We present analytical results for the action of the field theory as the squashing parameter , alpha→ -1, when the boundary becomes effectively one dimensional. In this limit we solve the theory exactly and show that the action of the boundary theory scales as ln(1 + alpha)/(1 + alpha)[2] which is to be compared and contrasted with the -1/(1 + alpha)[2] scaling of gravity in AdS-Taub-NUT space. These results are consistent with the numerical evidence presented in hep- th/0503238, and the soft logarithmic departure is interpreted as a prediction for the contribution due to higher spin fields in the bulk AdS[4] geometry. We then give an introduction to non relativistic AdS/CFT and numerically compute the inter quark potential in the non relativistic theory obtained by taking the DLCQ of N = 4 SYM theory by considering Wilson loops in the dual string theory via the AdS/CFT correspondence.
APA, Harvard, Vancouver, ISO, and other styles
20

Stephens, Daniel J. "Realism, relativism, and Dao a look at language and normative social philosophy in Rorty and ancient China /." Thesis, Click to view the E-thesis via HKUTO, 2008. http://sunzi.lib.hku.hk/hkuto/record/B40988028.

Full text
APA, Harvard, Vancouver, ISO, and other styles
21

Papin, Morgane. "Apport de la bioacoustique pour le suivi d’une espèce discrète : le Loup gris (Canis lupus)." Thesis, Université de Lorraine, 2018. http://www.theses.fr/2018LORR0258/document.

Full text
Abstract:
Le nombre croissant de travaux réalisés ces dernières années a montré que la bioacoustique est particulièrement intéressante pour le suivi d’espèces discrètes. L’émergence de dispositifs d’enregistrement autonomes, associée à de nouvelles méthodes d’analyse, ont récemment participé à l’accroissement des études dans ce domaine. Au cours des 30 dernières années, le Loup gris (Canis lupus), mammifère carnivore aux mœurs discrètes connu pour ses hurlements de longue portée, a fait l’objet de nombreuses études acoustiques. Ces dernières visaient notamment à améliorer son suivi, qui s’avère complexe du fait des grandes capacités de déplacement des loups, de l’étendue de leurs territoires et de la diversité des milieux dans lesquels ils vivent. Cependant, la bioacoustique passive a jusqu’alors très peu été exploitée pour le suivi du Loup. C’est dans ce contexte que la présente thèse s’est organisée autour de trois axes de recherche. Les deux premiers axes portent sur l’apport de la bioacoustique passive pour le suivi du Loup gris en milieu naturel. En combinant des analyses acoustiques, statistiques et cartographiques, le premier objectif a été d’élaborer une méthode pour l’échantillonnage spatial de vastes zones d’étude, afin d’y détecter des hurlements de loups à l’aide de réseaux d’enregistreurs autonomes. Ce même dispositif a ensuite permis, dans un second temps, de tester la possibilité de localiser les loups grâce à leurs hurlements. Les expérimentations conduites en milieu de moyenne montagne (Massif des Vosges) et de plaine (Côtes de Meuse), sur deux zones d’étude de 30 km² et avec un réseau de 20 enregistreurs autonomes, ont permis de démontrer l’intérêt de la bioacoustique passive pour le suivi du Loup gris. En effet, près de 70% des émissions sonores (son synthétique aux propriétés similaires à celles de hurlements de loups) ont été détectés par au moins un enregistreur autonome en milieu de moyenne montagne et plus de 80% en milieu de plaine, pour des distances enregistreurs– source sonore atteignant respectivement plus de 2.7 km et plus de 3.5 km. Grâce à un modèle statistique et à un Système d’Information Géographique, la probabilité de détection des hurlements a pu être cartographiée sur les deux zones. En moyenne montagne, elle était forte à très forte (>0.5) sur 5.72 km² de la zone d’étude, contre 21.43 km² en milieu de plaine. Les sites d’émission ont été localisés avec une précision moyenne de 315 ± 617 (SD) m, réduite à 167 ± 308 (SD) m après l’application d’un seuil d’erreur temporelle défini d’après la distribution des données. Le troisième axe de travail porte quant à lui sur l’application d’indices de diversité acoustique pour estimer le nombre d’individus participant à un chorus et ainsi contribuer au suivi de l’effectif des meutes. Les valeurs obtenues pour les six indices (H, Ht, Hf, AR, M et ACI) étaient corrélées avec le nombre de loups hurlant dans les chorus artificiels testés. De bonnes prédictions de l’effectif ont été obtenues sur des chorus réels avec l’un de ces indices (ACI). L’influence de plusieurs biais sur la précision des prédictions de chacun des six indices a ensuite pu être étudiée, montrant que trois d’entre eux y étaient relativement peu sensibles (Hf, AR et ACI). Finalement, les résultats obtenus avec les enregistreurs autonomes montrent le potentiel des méthodes acoustiques passives pour la détection de la présence de loups mais aussi pour les localiser avec une bonne précision, dans des milieux contrastés et à de larges échelles spatiale et temporelle. L’utilisation des indices de diversité acoustique ouvre également de nouvelles perspectives pour l’estimation de l’effectif des meutes. Prometteuses, l’ensemble des méthodes émergeant de ce travail nécessite à présent quelques investigations complémentaires avant d’envisager une application concrète pour le suivi du Loup gris dans son milieu naturel
The growing number of studies carried out in recent years has shown that bioacoustics is particularly interesting for the monitoring of secretive species. The emergence of autonomous recording devices, combined with new methods of analysis, have recently contributed to the increase of studies in this field. Over the last 30 years, many bioacoustic studies have been developed for the Grey wolf (Canis lupus), a secretive large carnivore known for its howls spreading over distances up to several kilometers. These researches notably aimed to improve its monitoring, which is complex because of the strong wolf dispersal capacities over long distances, the large extent of their territories and the various natural contexts in which they live. In this context, this PhD thesis was organized around three research axes. The first two axes focused on the contribution of passive bioacoustics for the Grey wolf monitoring in the field. By combining acoustic, statistical and cartographic analysis, the first objective was to develop a spatial sampling method adapted to large study areas for the detection of wolf howls by using autonomous recorders. Then, the same protocol was used to investigate the possibility to localize wolves thanks to their howls. Field experimentations, conducted in mid-mountain (Massif des Vosges) and lowland (Côtes de Meuse) environments, in two study areas of 30 km² and with an array of 20 autonomous recorders, demonstrated the high potential of passive bioacoustics for the Grey wolf monitoring. Indeed, nearly 70% of broadcasts (synthetic sound with similar acoustic properties to howls) were detected by at least one autonomous recorder in mid-mountain environment and more than 80% in lowland environment, for sound source-recorders distances of up to 2.7 km and 3.5 km respectively. By using statistical model and Geographic Information System, the detection probability of wolf howls was modeled in both study areas. In the mid-mountain environment, this detection probability was high or very high (greater than 0.5) in 5.72 km² of the study area, compared with 21.43 km² in lowland environment. The broadcast sites were localized with an overall mean accuracy of 315 ± 617 (SD) m, reducing until 167 ± 308 (SD) m after setting a temporal error threshold defined from the data distribution. The third axe focused on the application of acoustic diversity indices to estimate the number of howling wolves in choruses and thus to contribute to pack size monitoring. Index values of the six indices (H, Ht, Hf, AR, M, and ACI) were positively correlated with the number of howling wolves in the artificial tested choruses. Interesting size predictions based on real choruses were obtained with one of the indices (ACI). The effects of several biases on the reference values for the acoustic indices were then explored, showing that three of them were relatively insensitive (Hf, AR and, ACI). Finally, results obtained with autonomous recorders confirm the real potential of passive acoustic methods for detecting the presence of wolves but also for localizing individuals with high precision, in contrasting natural environments, at large spatial and temporal scales. The use of acoustic diversity indices also opens new perspectives for estimating pack sizes. All of the promising methods emerging from this thesis require now further investigations before considering a concrete application for monitoring the Grey wolf in its natural environment
APA, Harvard, Vancouver, ISO, and other styles
22

Pafundi, Brian S. "Nancy, Greta and Casey, oh my! public access to criminal discovery records : a look behind the curtain in the age of the twenty-four hour news cycle /." [Gainesville, Fla.] : University of Florida, 2009. http://purl.fcla.edu/fcla/etd/UFE0025053.

Full text
APA, Harvard, Vancouver, ISO, and other styles
23

Schendel, Zachary Adam. "The irrelevant sound effect similarity of content or similarity of process? /." Columbus, Ohio : Ohio State University, 2006. http://rave.ohiolink.edu/etdc/view?acc%5Fnum=osu1148590088.

Full text
APA, Harvard, Vancouver, ISO, and other styles
24

Nataša, Lukić. "Samo-rotirajući impeleri u airlift reaktoru sa spoljašnjom recirkulacijom." Phd thesis, Univerzitet u Novom Sadu, Tehnološki fakultet Novi Sad, 2017. http://www.cris.uns.ac.rs/record.jsf?recordId=102693&source=NDLTD&language=en.

Full text
Abstract:
Cilj doktorske disertacije je poboljšanje hidrodinamičkih imasenoprenosnih karakteristika airlift reaktora saspoljašnjom recirkulacijom umetanjem samo-rotirajućihimpelera u uzlaznu cev. Uticaj ugradnje samo-rotirajućihimpelera na osnovne hidrodinamičke i masenoprenosneosobine ispitivan je pri radu sa različitim tečnostima idistributorima gasa. Rezultati su tumačeni poređenjemvrednosti za sadržaj gasa u uzlaznoj cevi, za brzinutečnosti u silaznoj cevi, i za zapreminski koeficijentprenosa mase, dobijenih za dve konfiguracije reaktora (sai bez impelera).Rezultati disertacije ukazuju da ugradnja samo-rotirajućihimpelera dovodi do znatnog razbijanja mehurova ismanjenja srednjeg prečnika mehurova gasa, naročito uviskoznim rastvorima karboksimetilceluloze. Prividnabrzina gasa, vrsta tečne faze i tip distributora gasa uvelikoj meri utiču na efikasnost samo-rotirajućih impelera.Dobijene vrednosti sadržaja gasa u uzlaznoj cevi su do47% veće u konfiguraciji sa impelerima u odnosu nakonfiguraciju bez impelera. Iako samo-rotirajući impeleripredstavljaju dodatni otpor proticanju tečnosti, njihovomugradnjom je u svim ispitivanim sistemima postignutorelativno malo smanjenje brzine tečnosti (oko 10%).Zahvaljujući impelerima, zapreminski koeficijent prenosamase uvećan je do 82% pri manjim protocima gasa. Privećim protocima, koji odgovaraju uslovima rada koji sesreću u većini fermentacionih procesa, postignute su oko20-30% veće vrednosti zapreminskog koeficijenta prenosamase.Pored empirijskih modela, u ovom radu uspešno surazvijeni i modeli veštačkih neuronskih mreža kojim sepredviđaju sadržaj gasa u uzlaznoj cevi, brzina tečnosti izapreminski koeficijent prenosa mase za obe konfiguracijeairlift reaktora sa spoljašnjom recirkulacijom.
The aim of this study was intensification ofhydrodynamic and mass transfer properties ofexternal-loop airlift reactor by means of self-agitatedimpellers mounted in the riser section. The influenceof impellers’ insertion on the main hydrodynamicand mass transfer characteristics was investigated forvarious liquid phases and sparger types. The valuesof riser gas holdup, downcomer liquid velocity andvolumetric mass transfer coefficient obtained inconfigurations with and without impellers werecompared.Results showed that the installment of self-agitatedimpellers led to a significant bubble breakage anddecrease of bubble size, especially in viscouscarboxymethylcellulose solutions. The efficiency ofself-agitated impellers was immensely influenced bysuperficial gas velocity, liquid phase, and distributortype. Obtained riser gas holdup values were up to47% higher in the configuration with impellers, incomparison to the configuration wthout impellers.Despite the fact that self-agitated impellersrepresented an obstacle to liquid flow, relatively lowreduction of downcomer liquid velocity was attained(about 10%). Furthermore, the insertion of impellersinduced up to 82% higher values of volumetric masstransfer coefficient at lower superficial gas velocities.At higher superficial gas velocities, i.e. conditionsmainly operated in various fermentation processes,about 20-30% higher values of volumetric masstransfer coefficient were achieved with impellers.In addition to empirical correlations, artificial neuralnetwork models were sucessfully developed topredict riser gas holdup, downcomer liquid velocityand volumetric mass transfer coefficient in bothexternal-loop airlift configurations.
APA, Harvard, Vancouver, ISO, and other styles
25

Aleksandar, Kosina. "Priroda funkcija, njihovih oblika i odnosa u ljudskom okruženju." Phd thesis, Univerzitet u Novom Sadu, Fakultet tehničkih nauka u Novom Sadu, 2018. https://www.cris.uns.ac.rs/record.jsf?recordId=107172&source=NDLTD&language=en.

Full text
Abstract:
U radu se proučava poreklo funkcija, veza sistema povreatnih sprega sa uspostavljanjem funkcija, primarne funkcije kao funkcije fizičkog protoka između adaptivnih sistema i njihovog okruženja, perceptivno-analitičke funkcije kao funkcije informacionih protoka između adaptivnih sistema i okruženja, strukture obrazaca prirodnog i ljudskom rukom oblikovanih delova okruženja i sistemi ideja u oblikovanju okruženja.
Origins of functions, connections of feedback systems with emerging offunctions, primary functions as functions of physical flow between adaptivesystems and their environment, perceptual-analytical functions as functionsof information flow between adaptive systems and their environment,structures of patterns (levels of form) of natural and human designedelements of environment, historical developement and complexification ofrelationships of human soci-eties with their environment.
APA, Harvard, Vancouver, ISO, and other styles
26

Röthig, Sabine. "Windowlicker." Doctoral thesis, Humboldt-Universität zu Berlin, Kultur-, Sozial- und Bildungswissenschaftliche Fakultät, 2016. http://dx.doi.org/10.18452/17491.

Full text
Abstract:
In der Arbeit wird das Zusammentreffen der aus dem Club kommenden Electronic Dance Music (EDM) mit dem massenmedial konsolidierten Musikvideo untersucht. Diskutiert wird die These eines ästhetischen Paradigmenwechsels, der sich dadurch im Musikvideo vollzieht. Dieser beruht vor allem auf der musikalischen Figur des instrumentalen, modularen Tracks, die sich signifikant von der des Songs unterscheidet. Der originäre Zweck des Musikvideos, den Auftritt des Interpreten auf dem Monitor zu visualisieren, steht also mit dem Track zur Disposition oder wird gar obsolet; das erfordert neue Strategien der Bebilderung. Teil I und II der Arbeit verorten Musikvideo und EDM im wissenschaftlichen Diskurs und versammeln die jeweiligen ästhetischen Attribute. In Teil III wird anhand der Club Visuals die Beziehung von Tracks und Bildern erörtert, um darüber die veränderte Klang-Bild-Konstellation im Musikvideo durch EDM herzuleiten. In Teil IV werden die Erkenntnisse anhand der Fallstudie, dem Musikvideo „Windowlicker“ von Aphex Twin (Musik) und Chris Cunningham (Regie) aus dem Jahr 1999 ausgewertet und angewendet. Die Arbeit möchte die Dimension der ästhetischen Studien um das Musikvideo erweitern und verdeutlichen, wie sich das Musikvideo auch unter veränderten klanglichen Bedingungen als unentbehrlicher Bestandteil der Aufführung von Popmusik in der Monitorkultur erweist und als künstlerisches Genre unbedingt ernst zu nehmen ist, da sich in ihm zeitgenössische Avantgarden abbilden können.
This thesis explores the relationship between Electronic Dance Music (EDM) which originated in clubs, and the mass media consolidated music video. Focussing on how EDM influences the music video, an aesthetic paradigm shift on the latter is discussed. This change stemmed mainly from the structure of the instrumental, modular EDM track, which is significantly different from the structure of the song. Originally, the music video was intended as way of visualising the performance of the artist on the monitor; however, the advent of instrumental EDM tracks posed critical problems for this approach, and arguably renders it obsolete. New strategies of illustrations are required. Parts I and II of this thesis analyse music video and EDM through scientific discourses in an attempt to define their respective aesthetic attributes. In part III the relationship between tracks and images in club visuals is discussed in order to illustrate the singularity of this dialogue. In part IV, conclusions from the foregoing sections are evaluated and applied to a study of “Windowlicker” by British artist Aphex Twin, the video to which was directed by Chris Cunningham in 1999. The purpose of this thesis is to extend the aesthetic studies of the music video to clarify its status as an essential part of popular music in monitor culture. As an artistic genre it has to be taken seriously because it can display contemporary avant-gardes.
APA, Harvard, Vancouver, ISO, and other styles
27

Hait, Jan Joseph. "Prophylaktische Loop-Recorder Implantation zur Detektion kardialer Rhythmusstörungen bei Patienten mit Fabry-Kardiomyopathie: 2-Jahres-Follow-Up." Doctoral thesis, 2020. https://nbn-resolving.org/urn:nbn:de:bvb:20-opus-203337.

Full text
Abstract:
Patienten mit fortgeschrittenem Morbus Fabry neigen zu einer Vielzahl an kardiologischen Symptomen, u.A. Herzrhythmusstörungen. Diese sind prognostisch natürlich relevant. Um diese detektieren zu können, erhielten unsere Patienten implantierbare Loop-Recorder. Schon in der ersten Studie konnten so einige signifikante Herzrhythmusereignisse diagnostiziert und eine klinische Konsequenz daraus gezogen werden. Diese Studie stellt nun ein 2-Jahres-Follow-Up zur ersten Studie dar
Patients with anderson-fabry disease show a variety of cardiac symptoms including arrhythmias, which are crucially relevant in terms of prognosis. In order to detect those, we used implantable loop recorders. Some cardiac events could already be detected in the first study, each of which had a certain clinical consequence. This study now aims to do a 2 year follow-up
APA, Harvard, Vancouver, ISO, and other styles
28

Piegsa, Julia, Franziska Markel, Ingo Dähnert, Anna Michaelis, Roman Antonin Gebauer, and Christian Paech. "Use of the Medtronic REVEAL LINQ implantable loop recorder in patients after Mustard or Senning procedure: Medtronic LINQ after Mustard / Senning procedure." 2020. https://ul.qucosa.de/id/qucosa%3A75501.

Full text
Abstract:
Background: Patients with d-transposition of the great arteries after Senning or Mustard procedure are at increased risk for arrhythmias. Especially atrial arrhythmias represent a major threat in this patient population. Early detection of clinical and subclinical arrhythmias may prevent major cardiac events. Therefore, this study aimed to evaluate the ability of the Medtronic REVEAL LINQ to detect atrial arrhythmias in adult patients after atrial switch procedure and compare the effectiveness of detecting clinically relevant arrhythmias to conventional Holter monitoring. METHODS: The database of the Heart Center Leipzig, Department for pediatric cardiology was analyzed for patients after atrial switch procedure and implantation of a Medtronic REVEAL LINQ (Medtronic Inc., Minneapolis, Minnesota). After informed consent was obtained, patients were followed up for 1 year including Holter ECG tracings and device interrogation every 3 months. In addition, symptoms were determined using a standardized questionnaire completed by the patient. RESULTS: The analysis is based on 10 patients aged 34.5 years (range 27-46 years), of which 8 had a Senning - and 2 had a Mustard procedure. The comparison of the number of arrhythmia episodes detected by Holter and LINQ showed significantly more detected episodes using LINQ (p 0.014). Data showed that no therapy adjustments were recorded as a consequence of Holter ECG findings, whereas two changes in medication were documented due to arrhythmia detection via LINQ. When analyzing possible correlations between subjective symptoms reported in the standardized questionnaire and the number of episodes documented, there was a significant correlation of subjective symptoms and arrhythmia episodes in LINQ (p 0.014), whereas no correlation could be demonstrated between subjective symptoms and the number of episodes detected by Holter monitoring (p 0.394). CONCLUSION: In patients after Senning or Mustard procedure, the Medtronic REVEAL LINQ seems to be superior in the identification of subclinical arrhythmia burden in comparison to standard Holter ECG.
APA, Harvard, Vancouver, ISO, and other styles
29

Kreuzhuber, Manuela. "Erste klinische Erfahrung mit einem implantierbaren kardialen Monitor zur Detektion von Vorhofflimmern." Doctoral thesis, 2012. https://ul.qucosa.de/id/qucosa%3A12257.

Full text
Abstract:
EINLEITUNG Vorhofflimmern und orale Antikoagulation Vorhofflimmern stellt ein Grundproblem der modernen Gesellschaft dar und fordert zunehmend den Einsatz medizinischer Ressourcen. Es ist die Folge eines komplexen Prozesses aus Triggern, elektrophysiologischen und später auch strukturellen Umbauprozessen im Vorhofmyokard. Man unterscheidet paroxysmales von persistierenden und permanenten Vorhofflimmern. Zusätzlich muss man symptomatische Episoden von asymptomatischen trennen, wobei der Anteil letzterer mit bis zu 70% beschrieben wird. Asymptomatisches Vorhofflimmern wird als eine häufige Ursache eines kryptogenen Schlaganfalls vermutet. Bislang konnte gezeigt werden, dass längere Überwachungszeiträume des Herzrhythmus häufiger Vorhofflimmern bei dieser Patientengruppe erfassen können. Somit hat hier der Nachweis von Vorhofflimmern einen entscheidenden Einfluss auf die Therapie durch entsprechende Senkung des thrombembolischen Risikos. Bei Patienten mit bekanntem Vorhofflimmern dagegen besteht die Gefahr einen Therapieerfolg aufgrund asymptomatischer Episoden zu überschätzen und die Vorhofflimmerlast, den sogenannten AF Burden zu unterschätzen. Entsprechend waren und sind mit dem subjektiven Therapieerfolg medizinische Entscheidungen verbunden, welche in Bezug auf das Auftreten thrombembolischer Ereignisse eine gewisse Rolle spielen. Statistisch gesehen wird das thrombembolische Risiko nach dem CHADS2 oder CHA2DS2 VASc Score berechnet und danach zwischen einer Plättchenhemmung, einer oralen Antikoagulation, direkten Thrombin-, Faktor Xa Inhibitoren oder keiner weiteren Therapie entschieden. Patienten mit Vorhofflimmern können auf zwei Arten behandelt werden. Bei der sogenannten Frequenzkontrolle erfolgt kein direkter Angriff auf die Rhythmusstörung, nur auf die Geschwindigkeit der Herzfrequenz und deren Symptome. Demgegenüber steht die Rhythmuskontrolle mit vordergründigem Erhalt des Sinusrhythmus, sowohl elektrisch, als auch medikamentös oder interventionell. Die Erfassung des Herzrhythmus und der implantierbare kardiale Monitor Ob ein Sinusrhythmus oder Vorhofflimmern vorliegt kann nur anhand eines EKGs geklärt werden. Zur Überwachung eines längeren Zeitraums kommen sogenannte Holter-EKGs mit einer Aufzeichnungsdauer von mindestens 24 Stunden, maximal 7 Tagen in Frage. Aufgrund von seltenen, wahrscheinlich rhythmogen bedingten Symptomen wie zum Beispiel Synkopen, wurde eine Weiterentwicklung mit noch längeren Aufzeichnungskapazitäten notwendig. Dem externen Event- und Loop-Recorder folgte der implantierbare kardiale Monitor. Der Reveal XT 9529 (Medtronic Inc, Minneapolis), ein implantierbarer kardialen Monitor mit einem speziellen Detektionsalgorithmus für Vorhofflimmern ist dabei Gegenstand dieser Untersuchung. ZIEL DER ARBEIT Evaluierung des REVEAL XT 9529 (Medtronic Inc, Minneapolis) bei einer Patientenpopulation mit Vorhofflimmern im klinischen Alltag. METHODEN Der automatische Detektion von Vorhofflimmern durch einen implantierten kardialen Monitor unterliegt eine Analyse des R-Zacken Abstandes innerhalb von zwei Minuten. Kommt es hier zu Unregelmäßigen erfolgt automatisch eine Einordnung des Herzrhythmus in den Bereich Vorhofflimmern (AF). Die Episoden können in der Regel manuell mit einem Frequenzplot und einer EKG-Ableitung (EGM) überprüft werden. Analysiert wurde eine Gruppe von 92 Patienten, welche vorrangig an Vorhofflimmern litten. Zusätzliche Daten wie Alter, Geschlecht, linksventrikuläre Pumpfunktion, kardiale Begleiterkrankungen und medikamentöse Therapie wurden ebenfalls erfasst. 88% der mit dem implantierbaren kardialen Monitor versorgten Patienten wurden aufgrund des Vorhofflimmerns vorbehandelt, bei 82% stand ein neuerlicher Therapieversuch bevor. Die Implantation des kardialen Monitors fand unter sterilen Operationsbedingungen statt, nachfolgend wurden die Patienten in die Funktion eingewiesen. Die Termine zur Nachsorge wurden im Rahmen der klinischen Routine vergeben und umfassten eine Überprüfung und Wertung der automatisch detektierten Rhythmusereignisse. Bei einer Untergruppe von 62 Patienten erfolgte parallel die Anlage von 7 Tage Langzeit-EKGs und eine Wertung der Ergebnisse im Vergleich. Die statistische Datenanalyse erfolgte mit Microsoft Office Excel 2007 und SPSS, Version 11.5.1. Mittelwerte werden mit Standardabweichung angegeben, im Falle des Medians zusätzlich Minimum und Maximum. Prozentuelle Angaben erfolgen bei Zahlen. Für statistisch abhängige Stichproben erfolgte die Anwendung des McNemar Tests, für unabhängige Werte der Chi-Quadrat Test. Es gilt das allgemein übliche Signifikanzniveau von p < 0,05. ERGEBNISSE Die Ergebnisse der manuellen Überprüfung wurden in folgende Kategorien eingeteilt: 1. Kein Vorhofflimmern unter Einsicht sämtlicher EGMs. 2. Sicheres Vorhofflimmern mit eindeutigem Nachweis in den gespeicherten EGMs. 3. Mögliches Vorhofflimmern, aber ohne diagnostische Sicherheit, da ein EGM nicht vorliegt. Davon ausgehend erfolgte die weitere Unterteilung in: - Regelrechten Sinusrhythmus ohne Nachweis von Artefakten. - Regelrechten Sinusrhythmus, aber Aufzeichnung von Artefakten im Sinne einer Fehlklassifikation. - Regelrechten Nachweis von Vorhofflimmern und Fehlklassifikation von Sinusrhythmus bei Artefakten. - Fehlklassifikation von Sinusrhythmus bei Artefakten, zusätzlich diagnostische Unsicherheit ob Vorhofflimmern aufgetreten ist, da nicht alle EGMs einsehbar. Vor dem Softwareupgrade wurden 287 Abfragen von 92 Patienten analysiert. Im Durchschnitt wurden 1078 (± 4851) Episoden registriert, im Median lag diese Zahl bei 58 (0 – 67099). Bezogen auf das Auftreten von Vorhofflimmern blieben 55 (19%) der Abfragen ohne Episoden. Ein komplett einsehbarer EGM Speicher war bei 140 (49%) der Abfragen zu finden, bei 147 (51%) waren dagegen EGMs schon wieder überschrieben und damit nicht mehr überprüfbar. Unter diesen Patienten zeigten 53 (19%) reines Vorhofflimmern im Speicher, 21 (7%) Vorhofflimmern mit Artefakten und weitere 73 (25%) nur Sinusrhythmus mit Artefakten. Gerade bei dieser letzten Gruppe kann keine sichere Aussage über das reelle Auftreten oder Fehlen von Vorhofflimmern gemacht werden. Auf sämtliche Abfragen vor dem Softwareupgrade gesehen waren Muskelpotentiale, welche bei 134 (47%) von 287 Abfragen auftraten das Hauptproblem unter den Artefakten und Ursache für die automatische Fehlklassifikation. Weitere Fehlklassifikationen betrafen Undersensing, die Einordnung von Vorhofflimmern in den Bereich einer ventrikulären Tachykardie, ventrikuläre und supraventrikuläre Extrasystolen, den AT-Algorithmus und T-Wave Oversensing. In den verbleibenden 65 Patienten nach dem Softwareupgrade wurden 116 analysierbare Abfragen erhoben. Bezogen auf das Auftreten von Vorhofflimmern blieben 41 (35%) der Abfragen ohne Episoden. Ein komplett einsehbarer EGM Speicher war bei 78 (67%) der Abfragen zu finden. Unter den Patienten mit bereits überschriebenen EGM zeigten 17 (15%) reines Vorhofflimmern im Speicher, 9 (8%) Vorhofflimmern mit Artefakten und weitere 12 (10%) nur Sinusrhythmus mit Artefakten. Ein direkter Vergleich der Ergebnisse zeigte eine signifikante Reduktion der beschriebenen Fehlklassifikation von Vorhofflimmern aufgrund von Myopotentialen, Undersensing und des AT-Algorithmus. Für 62 der Patienten liegen im Mittel 502 (± 156), im Median 508 (51 – 677) Stunden an Langzeit-EKG Aufzeichnung vor. Vorhofflimmern kann 48% im Langzeit-EKG registriert werden, im Reveal XT 9529 (Medtronic Inc, Minneapolis) nach manueller Überprüfung der Episoden dagegen bei 81%. Das Signifikanzniveau liegt bei p < 0,001. DISKUSSION Nach den vorliegenden Ergebnissen dieser Arbeit zeigt sich, dass die grundlegende Forderung nach einer kontinuierlichen EKG-Überwachung nur eingeschränkt mit dem Reveal XT 9529 (Medtronic Inc, Minneapolis) zu erreichen ist. Es traten zahlreiche Probleme mit Artefakten durch das beschriebene Oversensing und aufgrund der Speicherkapazität auf. Lösungsansätze sind hier die stärkere Einbeziehung des “Patient Assistant“ beziehungsweise ein Remote-Follow-Up. Bereits initiiert wurde ein Softwareupgrade welches durch Ausweitung des “Noise“ die Artefaktanfälligkeit deutlich senken konnte. Zusätzlich stehen die direkte Anpassung der Programmierung und die Anpassung der Sensitivität zur Verfügung. Diskutiert werden sollte weiterhin eine Veränderung des Erkennungsalgorithmus mit 2-dimensionaler Auswertung der RR-Intervalle und der RR-Differenz. Zusätzlich muss der Einfluss des Patienten auf die Handhabung des Systems im Blick behalten werden. Grundsätzlich sind zum einen das technische Verständnis, zum anderen die Compliance, welche durch verschiedene Faktoren geprägt wird. Der Einfluss eines kontinuierlichen EKG-Monitorings auf das Management der oralen Antikoagulation und Rezidive von Vorhofflimmern birgt ein enormes Potential wie Daten bei Schrittmacher- und ICD-Patienten zeigen. Trotzdem sind hier viele wichtige Studien zum aktuellen Zeitpunkt ausstehend. Festzuhalten bleibt, dass Studien im allgemeinen und speziellen durch den Einsatz eines implantierbaren kardialen Monitors effektiver gestaltet, Rezidive der Rhythmusstörung sicherer erfasst werden würden und auch eine Anpassung der oralen Antikoagulation denkbar ist. Weiterhin wären im Bereich des kryptogenen Schlaganfalls höhere Aufklärungsraten anzunehmen. Im Vergleich mit einem 7 Tage Langzeit-EKG zeigt ein implantierbarer kardialer Monitor eine vermehrte Erfassung von Vorhofflimmern trotz der beschriebenen Probleme. Zu diskutieren bleiben die Invasivität des Verfahrens und die endgültigen Kosten. LIMITATIONEN Das vorgestellte Patientenkollektiv wurde nicht prospektiv untersucht, sondern im Rahmen einer Observationsstudie retrospektiv analysiert. Zusätzlich handelt es sich um eine selektionierte Gruppe von Patienten, zumeist mit dem Ziel einer invasiven Ablationsbehandlung und dadurch vorgegeben, einigen Besonderheiten. Zu beachten ist außerdem, dass einzig die Problematik in Bezug auf Vorhofflimmern untersucht, andere messbare Rhythmusstörungen im Rahmen dieser Analyse ausgeschlossen wurden. AUSBLICK Vorhofflimmern und seine Therapie wird ein relevanter Faktor in der Zukunft vieler betroffener Patienten bleiben, die Forderung nach einer kontinuierlichen EKG-Überwachung für verlässliche Aussagen sich entsprechend verstärken. Die erste Generation der implantierbaren kardialen Monitore stellt einen vielversprechenden Anfang dar. Weitere Entwicklungen mit Verbesserung der Artefaktanfälligkeit und Speicherkapazität, sowie der Telemedizin sind notwendig. Gerade mit Blick auf asymptomatisches Vorhofflimmern sind viele Fragen offen und können nur mit einer lückenlosen, sensitiven und spezifischen EKG-Dokumentation beantwortet werden.
APA, Harvard, Vancouver, ISO, and other styles
30

"Optically-controlled generation of wavelength-tunable pulses from semiconductor and fiber lasers using a nonlinear optical loop mirror." 2001. http://library.cuhk.edu.hk/record=b5890622.

Full text
Abstract:
Tang Wing-Wa.
Thesis (M.Phil.)--Chinese University of Hong Kong, 2001.
Includes bibliographical references.
Abstracts in English and Chinese.
Abstract --- p.i
Acknowledgement --- p.iv
Table of contents --- p.v
List of figure --- p.viii
Chapter 1. --- Introduction --- p.1
Chapter 1.1. --- Introduction to ultrashort optical pulse generation --- p.2
Chapter 1.2. --- Introduction to wavelength-tunable pulse generation --- p.5
Chapter 1.3. --- Introduction to chapters --- p.7
Chapter 2. --- Principles and Theories --- p.11
Chapter 2.1. --- Principle of dispersion tuning --- p.12
Chapter 2.2. --- SOA nonlinear optical loop mirror --- p.16
Chapter 2.3. --- Principle of dispersion tuning in harmonically mode-locked fiber laser using nonlinear optical loop mirror --- p.19
Chapter 2.4. --- Principle of re-configurable multi-wavelength pulses generationin a self-seeded laser diode incorporating SOA loop mirror --- p.22
Chapter 3. --- Rational harmonic mode-locking of an optically triggered fiber laser incorporating a non-linear optical loop modulator --- p.25
Chapter 3.1. --- Introduction --- p.26
Chapter 3.2. --- Experiment --- p.27
Chapter 3.3. --- Result and discussion --- p.30
Chapter 3.4. --- Summary --- p.37
Chapter 4. --- Generation of amplitude-equalized optical pulses from a rational harmonic mode-locked fiber laser incorporating a SOA loop modulator --- p.40
Chapter 4.1. --- Introduction --- p.41
Chapter 4.2. --- Experiment --- p.42
Chapter 4.3. --- Result and discussion --- p.44
Chapter 4.4. --- Summary --- p.47
Chapter 5. --- Optically controlled dispersion-tuning in harmonically mode-locked erbium doped fiber laser using SOA nonlinear loop modulator --- p.49
Chapter 5.1. --- Introduction --- p.50
Chapter 5.2. --- Experiment --- p.51
Chapter 5.3. --- Result and discussion --- p.54
Chapter 5.4. --- Summary --- p.58
Chapter 6. --- Alternate method of constructing harmonically mode-locked fiber laser incorporating SOA nonlinear loop modulator --- p.60
Chapter 6.1. --- Introduction --- p.61
Chapter 6.2. --- Experiment --- p.62
Chapter 6.3. --- Result and discussion --- p.65
Chapter 6.4. --- Summary --- p.69
Chapter 7. --- Optically re-configurable multi-wavelength pulse source constructed from a self-seeded laser diode --- p.71
Chapter 7.1. --- Introduction --- p.72
Chapter 7.2. --- Experiment --- p.74
Chapter 7.3. --- Result and discussion --- p.77
Chapter 7.4. --- Summary --- p.82
Chapter 8. --- Tunable alternating multi-wavelength pulse source constructed using non-linear optical control of wavelength switching in a self-seeded laser diode --- p.85
Chapter 8.1. --- Introduction --- p.86
Chapter 8.2. --- Experiment --- p.87
Chapter 8.3. --- Result and discussion --- p.89
Chapter 8.4. --- Summary --- p.92
Chapter 9. --- Conclusion and future works --- p.94
Chapter 9.1. --- Conclusion --- p.94
Chapter 9.2. --- Possible future works --- p.98
Appendix
List of publications --- p.A-1
APA, Harvard, Vancouver, ISO, and other styles
31

Chen, Ku-Yi, and 陳谷易. "Adapting Ancient Wisdom: A Look at Principal Leadership through the Political Records of Zhen Guan Zheng Yao." Thesis, 2019. http://ndltd.ncl.edu.tw/handle/yarx82.

Full text
Abstract:
碩士
臺北市立大學
歷史與地理學系社會科教學碩士學位班
107
Tang Dynasty, under the reign of Emperor Taizong, enjoyed great prosperity in many aspects. “Zhen Guan Zheng Yao” is a set of political records complied by historian Wu Jing on the dialogues among Emperor Taizong and his chancellors. These records are considered by many as exemplary studying material of leadership. The wisdom that can be garnered from “Zhen Guan Zheng Yao” can even be applied to administrative leadership in education nowadays. 21stcentury education is complex and complicated; school principals have to lead their teams through various problems and challenges. A successful principal should be able to adapt ancient wisdom in his or her conduct, face problems with a positive attitude, and find the best solution. The contents of “Zhen Guan Zheng Yao” can be categorized in four sections:“accepting critique and opinions”, “appointing worthies and be fair”, “be respectful and modest”, and“repenting errors and be respectful of teachers”. A successful principal should be affirmative in his or her guidance, and be able to cultivate the greatest potential in his or her team, thereby earning the acceptance of his or her staff. As suggested by “Zhen Guan Zheng Yao”, principals should shape a vision of success for the school, motivate staff and teachers to work toward achieving that vision, and be charismatic, inspiring, and supporting. Zhen Guan Zheng Yao can offer strategic solutions for principals facing leadership difficulties. Nip the problem in the bud is a perfect example. Before setting a policy into motion, a successful principal should be attentive to the thoughts and feelings of the teachers, thus can he or she straighten out the problems and gain the acceptance of the teachers. “Confucian Analects”, “The Romance of Three Kingdoms”, “The Dream of the Red Chamber”, “Zhen Guan Zheng Yao”, and “The Altar Sutra of Sixth Patriarch” are Chinese classics that can offer insight and inspiration of leadership to school principals. Only by always learning, self-reflecting, and repenting one’s attitude on critique and differences in opinions, can true leadership be achieved. Among the principals interviewed, most agreed that a successful leader should be openminded about learning new things, reflecting one’s conduct, and be able to make the best decision after listening to the various suggestions and critique from teachers, parents, and society. Successful leadership is more than just listening to all the different perspectives, it also includes conveying the differences to all parties involved, and bringing them together for a win-win situation.
APA, Harvard, Vancouver, ISO, and other styles
32

"An in-depth look of phonological processing in Chinese character recognition: the effects of task." 1997. http://library.cuhk.edu.hk/record=b5889289.

Full text
APA, Harvard, Vancouver, ISO, and other styles
33

"Adding perceived behavioral control to the theory of reasoned action: time to look back and think." 1997. http://library.cuhk.edu.hk/record=b5889304.

Full text
Abstract:
Shu-Fai Cheung.
Thesis (M.Phil.)--Chinese University of Hong Kong, 1997.
Includes bibliographical references (leaves 48-57).
Acknowledgement --- p.2
Abstract --- p.3
The Theory of Planned Behavior --- p.4
Current Status --- p.7
Research Questions --- p.17
Method --- p.20
Data Analysis Procedure --- p.27
Results --- p.31
Discussion --- p.40
References --- p.48
Footnotes --- p.57
Chapter Table 1 --- Descriptive information of studies --- p.58
Chapter Table 2 --- Effect of TOPB and PBC for the whole data set --- p.59
Chapter Table 3 --- Descriptive statistics of mean PBC ratings --- p.60
Chapter Table 4 --- Weighted mean PBC rating for each type of PBC operationalization and each type of beahvioral domain --- p.61
Chapter Table 5 --- Unique Effect of PBC across operationalization of PBC --- p.62
Chapter Table 6 --- Unique Effect of PBC across operationalization of intention --- p.63
Chapter Table 7 --- Effect of Intention's and Control's Operationalization on Predicting Intention --- p.64
Chapter Table 8 --- Effect of Intention's and Control's Operationalization on Predicting Behavior --- p.65
Chapter Figure 1. --- The Theory of Planned Behavior --- p.66
Chapter Figure 2. --- Schematic Representation of Research Questions --- p.67
Chapter Figure 3. --- Schematic Representation of Research Questions --- p.68
Chapter Appendix A --- Article list --- p.69
Chapter Appendix B --- Using the delta method to derive a semipartial correlation's variance --- p.74
APA, Harvard, Vancouver, ISO, and other styles
34

Gillis, Virginia. "The deconstructive reader and the Stephen/Bloom artist : a closer look at Buck, Boylan, and the bond /." 2005. http://www.consuls.org/record=b2742104.

Full text
Abstract:
Thesis (M.A.) -- Central Connecticut State University, 2005.
Thesis advisor: Robert Dunne. "... in partial fulfillment of the requirements for the degree of Master of Arts in English." Includes bibliographical references (leaves 76-78). Also available via the World Wide Web.
APA, Harvard, Vancouver, ISO, and other styles
35

"Chinese medicine: a critical look from the health care angle : its value, methodology of research & utilisation." Thesis, 2005. http://library.cuhk.edu.hk/record=b6073979.

Full text
Abstract:
I. Exploring the prevalence of Chinese medicine. A questionnaire survey was conducted in 100 healthy people and 82 breast cancer patients. The survey showed that a very high prevalence of using Chinese medicine as a health supplementary was found among the healthy people (98%). The prevalence was even higher among breast cancer patients (99%).
II. Evidence based evaluation of the efficacy of Chinese medicine . The public's increasing use of Chinese medicine has added urgency to the need of examining the efficacy and safety of Chinese medicine practice and product. In order to understand the efficacy of Chinese medicine and the feasibility of standard research methodology of evidence-based medicine, two clinical trials were conducted in 100 healthy subjects and 82 breast cancer patients using the preparation contains YunZhi (Coriolus versicolor ) and Danshen (Radix Salviae miltorrhizae). The findings showed that the YunZhi and Danshen compound significantly enhanced the quality of life in healthy and some breast cancer subjects with reference to physical, emotional and health transitions.
III. Role of Chinese medicine in our health care system. Chinese medicine has been used for more than 3000 years in China and there have been numerous reports of efficacy. Chinese medicine would be offering solutions to some medical condition, where modern medicine yet failed to provide effective solution. Examples included chronic diseases, viral infections, allergies, derangements, cancers, etc. The health care system could provide the public alternative choices of medical treatment related to Chinese medicine as valuable supplements to modern medicine. (Abstract shortened by UMI.)
The use of alternative medicine has become increasingly popular around the world, mainly because of growing interest in holistic medicine and natural methods of healing. The Public is becoming increasingly aware of the limits of Modern medicine, and is looking forward to the possible benefits of alternative medicine. Because of the lack of perfect confidence on Modern medicine due to the unclear role of health promotion and unsatisfactory outcome of chronic diseases, people turn to alternative medicine. In Hong Kong, alternative medicine in reality, means very much Chinese medicine. A better understanding of the prevalence of Chinese medicine is needed in order to determine what needs to be done to improve the safety and efficacy of Chinese medicine with regard to its service role in the Health Care System. This thesis is structured to assess the popularity and peoples' attitude of Chinese medicine in Hong Kong; to assess the validity of evidence-based approach in the evaluation of the efficacy of Chinese medicine; and to explore the role of Chinese medicine in health care in the Health Care System.
by Wong Lai-Yi.
"January 2005."
Advisers: Ping-Chung Leung; Jin-Ling Tang.
Source: Dissertation Abstracts International, Volume: 67-01, Section: B, page: 0219.
Thesis (Ph.D.)--Chinese University of Hong Kong, 2005.
Includes bibliographical references (p. 175-212).
Electronic reproduction. Hong Kong : Chinese University of Hong Kong, [2012] System requirements: Adobe Acrobat Reader. Available via World Wide Web.
Electronic reproduction. [Ann Arbor, MI] : ProQuest Information and Learning, [200-] System requirements: Adobe Acrobat Reader. Available via World Wide Web.
Abstracts in English and Chinese.
School code: 1307.
APA, Harvard, Vancouver, ISO, and other styles
36

"The effect of scleraxis-transduced tendon-derived stem cells (TDSCs) on tendon repair in a rat model." 2013. http://library.cuhk.edu.hk/record=b5549324.

Full text
Abstract:
我們假設,將scleraxis (Scx)基因轉導入肌腱來源的幹細胞(TDSC),製成TDSC-Scx細胞系。TDSC-Scx會促進肌腱修復。本研究的目的在於探索Scx促進TDSC成肌腱分化的作用,以及TDSC-Scx對肌腱修復的促進作用。
使用慢病毒載體將Scx轉導入TDSCs,不含Scx的空載作為對照也轉導入TDSCs,用載體上帶有的抗性基因,殺稻瘟菌素對細胞進行篩選。分別建成TDSC-Scx和TDSC-Mock細胞系。Scx 的表達分別用定量PCR以及免疫螢光在mRNA和蛋白水準進行鑒定。TDSC-Scx成肌腱,成軟骨和成骨方向的分化能力用定量PCR檢驗。用大鼠臏腱視窗損傷模型進行了細胞移植試驗,測試TDSC-Scx對肌腱損傷的修復作用。實驗分為三組:(1)支架組,(2)空載體組,(3)Scx組。在細胞移植後的第二,四,八周,收集正在修復中的肌腱樣品,進行植入細胞的存留狀態,鈣化,組織學和生物力學測驗。
TDSC-Scx比TDSC-Mock有更強的成肌腱分化能力。但是,在成軟骨-成骨分化方面,沒有結論。在動物試驗,植入的細胞在第二周仍然可見,但自第四周起,就不見了。在第八周,各組均有個別樣品輕微異位鈣化,但各組別間並無顯著差異。在早期,TDSC-Scx組比空載體組和支架組合得來更好的修復肌腱的能力。
TDSC-Scx可能促進肌腱損傷的早期修復。
We hypothesized that transduction of tendon-derived stem cell (TDSC) with scleraxis (Scx) might promote its tenogenic differentiation and promote better tendon repair compared to TDSC without Scx transduction. This study thus aimed to investigate the effect of Scx transduction on the tenogenic differentiation of TDSC and the effect of the resulting cell line in the promotion of tendon repair.
TDSCs were transduced with lentivirus-mediated Scx or empty vector and selected by blasticidin. The mRNA and protein expression of Scx were checked by qRT-PCR and Immuno fluorescence, respectively. The expression of different lineage markers were examined by qRT-PCR. A rat patellar tendon window injury model was used. The operated rats were divided into 3 groups: (1) scaffold-only group, (2) TDSC-Mock group and (3) TDSC-Scx group. At week 2, 4 and 8 post-transplantation, the repaired patellar tendon was harvested for ex vivo fluorescent imaging, vivaCT imaging, histology, or biomechanical test.
TDSC-Scx consistently showed higher expression of tendon-related markers compared to TDSC-Mock. However, the effect of Scx transduction on the expression of chondro-osteogenic markers was less conclusive. The transplanted TDSCs could be detected in the window wound at week 2 but not at week 4. Ectopic ossification was detected in some samples at week 8 but there was no difference among different groups. The TDSC-Scx group promoted early tendon repair histologically and biomechanically compared to the scaffold-only group and the TDSC-Mock group.
TDSC-Scx might be used for the promotion of early tendon repair.
Detailed summary in vernacular field only.
Detailed summary in vernacular field only.
Detailed summary in vernacular field only.
Detailed summary in vernacular field only.
Tan, Chunlai.
Thesis (M.Phil.)--Chinese University of Hong Kong, 2013.
Includes bibliographical references (leaves 66-70).
Abstracts also in Chinese.
Chapter Thesis/Assessment Committee --- p.i
Acknowledgment --- p.ii
Publication --- p.vi
Abstract --- p.vii
摘要 --- p.viii
Chapter Chapter 1 --- Tendon injury and tendon tissue engineering --- p.1
Chapter 1.1 --- Anatomy of tendon --- p.1
Chapter 1.2 --- Epidemiology of tendon injury --- p.3
Chapter 1.3 --- Process and problems of tendon healing --- p.4
Chapter 1.4 --- Current treatment and cell-based therapy for tendon repair --- p.5
Chapter 1.5 --- Transcriptional factor Scleraxis and tendon --- p.8
Chapter 1.5.1 --- Helix-loop-helix (HLH) and bHLH proteins --- p.8
Chapter 1.5.2 --- Scleraxis --- p.9
Chapter 1.6 --- Research focus and implications --- p.11
Chapter 1.7 --- Hypotheses and objectives of this study --- p.12
Chapter 1.8 --- Clinical significance --- p.13
Chapter Chapter 2 --- Materials and Methods --- p.14
Chapter 2.1 --- Study Design --- p.14
Chapter 2.2 --- Establishment of TDSC-Scx cell line --- p.15
Chapter 2.2.1 --- Isolation of TDSC and cell culture --- p.15
Chapter 2.2.2 --- Establishment of TDSC-Scx cell line --- p.17
Chapter 2.2.2.1 --- Construction of plasmid --- p.17
Chapter 2.2.2.2 --- Transfection --- p.23
Chapter 2.2.2.3 --- Infection --- p.24
Chapter 2.2.2.4 --- Selection --- p.24
Chapter 2.2.2.5 --- Characterization of TDSC-Scx and TDSC-Mock --- p.25
Chapter 2.2.2.5.1 --- qRT-PCR --- p.25
Chapter 2.2.2.5.2 --- Immune-fluorescent (IF) --- p.26
Chapter 2.2.2.6 --- Lineage marker expression --- p.26
Chapter 2.2.3 --- Data analysis --- p.29
Chapter 2.3 --- The effect of TDSC-Scx on healing in a patellar tendon window injury model --- p.30
Chapter 2.3.1 --- Animal surgery --- p.30
Chapter 2.3.2 --- Ex Vivo Fluorescence Imaging --- p.32
Chapter 2.3.3 --- vivaCT --- p.33
Chapter 2.3.4 --- Histology --- p.33
Chapter 2.3.5 --- Biomechanical test --- p.35
Chapter 2.3.6 --- Data analysis --- p.37
Chapter Chapter 3 --- Results --- p.38
Chapter 3.1 --- Generation of TDSC-Scx and TDSC-Mock cell lines --- p.38
Chapter 3.1.1 --- Plasmid --- p.38
Chapter 3.1.2 --- Cell morphology --- p.38
Chapter 3.1.3 --- Expression of Scx --- p.38
Chapter 3.1.4 --- Expression of chondro-/osteo-/tenogenic markers --- p.39
Chapter 3.2 --- The healing effect of TDSC-Scx on a patella tendon window injury model --- p.40
Chapter 3.2.1 --- The fate of transplanted cells --- p.40
Chapter 3.2.2 --- Ossification --- p.40
Chapter 3.2.3 --- Histology --- p.40
Chapter 3.2.3.1 --- Fiber arrangement --- p.41
Chapter 3.2.3.2 --- Cellularity --- p.41
Chapter 3.2.3.3 --- Cell alignment --- p.42
Chapter 3.2.3.4 --- Cell rounding --- p.42
Chapter 3.2.3.5 --- Vascularity --- p.43
Chapter 3.2.3.6 --- Fiber structure --- p.43
Chapter 3.2.3.7 --- Hyaline degeneration --- p.43
Chapter 3.2.3.8 --- Inflammation --- p.44
Chapter 3.2.3.9 --- Ossification --- p.44
Chapter 3.2.4 --- Biomechanical properties --- p.44
Chapter Chapter 4 --- Discussion --- p.55
Chapter 4.1 --- In vitro --- p.55
Chapter 4.1.1 --- Scx transduction did not lead to morphological change in TDSCs --- p.55
Chapter 4.1.2 --- Scx transduction led to higher expression of Scx mRNA --- p.55
Chapter 4.1.3 --- TDSC-Scx expressed higher levels of tenogenic markers --- p.56
Chapter 4.2 --- In vivo --- p.58
Chapter 4.2.1 --- The fate of transplanted cells --- p.58
Chapter 4.2.2 --- Ossification was vague --- p.58
Chapter 4.2.3 --- TDSC-Scx promoted tendon healing --- p.58
Chapter 4.2.4 --- Biomechanical properties --- p.59
Chapter 4.2.5 --- Clinical consideration --- p.60
Chapter 4.3 --- Similar studies --- p.61
Chapter Chapter 5 --- Limitations --- p.63
Chapter 5.1 --- Direct Scx protein expression and function information unavailable --- p.63
Chapter 5.2 --- Differentiation assay --- p.64
Chapter Chapter 6 --- Conclusion --- p.65
Reference --- p.66
Appendix --- p.71
APA, Harvard, Vancouver, ISO, and other styles
37

"A 1.5 V, 2.4 GHz monolithic CMOS sub-integer-N frequency synthesizer for WLAN application." Thesis, 2011. http://library.cuhk.edu.hk/record=b6075113.

Full text
Abstract:
This thesis presents the design of a 2.4 GHz sub-integer-N PLL for IEEE 802.llb/g WLAN applications. The proposed PLL not only acquires the advantages of the integer-N PLL, such as simple structure and good spurious performance, but also offers some benefits (for example, faster settling time and better phase noise performance) as in the fractional-N PLL design. In this design, a novel quadrature-input programmable fractional frequency divider provides fractional division ratio in steps of 0.5 by the phase-switching technique. Its key building block is a dual divide-by-4 injection-locked frequency divider (ILFD), which is realized by coupling two conventional divide-by-4 ILFDs. Two different coupling schemes are introduced, namely the cross-coupling type and coherent-coupling type. In both schemes, symmetric configuration is maintained and hence does not degrade the PLL output phase quadrature accuracy. Furthermore, the generated phase pattern for phase switching is uniquely defined, which simplifies the phase-switching circuitry and suppresses the possibility of incorrect frequency division due to glitches.
To demonstrate the feasibility of the two proposed coupling methodologies, two subinteger-N PLLs with different fractional frequency dividers have been fabricated in a 0.35 11m standard CMOS process. In design 1, the dual divide-by-4 ILFD in the fractional frequency divider is implemented with the cross-coupling scheme while the coherent-coupling scheme is used in design 2. The measured spurious tones of both designs are under -64 dBc and their measured phase noise at 1 MHz frequency offset is less than -115 dBc/Hz. The two proposed frequency synthesizers settle at approximately 32 us and their phase mismatches of the quadrature outputs are better than 38 dB (characterized by image rejection ratio). Moreover, both designs individually occupy a chip area as small as 0.70 mm2. At a supply of 1.5 V, the total power consumption for each design is below 24.1 mW.
Wireless local area networks (WLANs) are being extensively deployed since their introduction in the late 1990s. Low cost, high performance frequency synthesizers are indispensable in WLAN telecommunication systems. Meanwhile, integer-N phase-locked loop (PLL) architecture is commonly chosen due to its low circuit complexity and clean output spectrum with few spurs. However, designers have to face the tradeoffs between frequency resolution, phase noise performance and switching time. To solve the above dilemma, fractional-N PLL architecture is proposed, but fractional spurs emerge in the output spectrum, degrading the spectrum purity. Sub-integer-N PLL is thus a compromise between the integer-N and fractional-N PLL. Its structure is same as that of the integer-N while fractional division is achieved by a fractional frequency divider that is not relied on time-varying modulus control as in the fractional-N PLL.
Chang, Ka Fai.
Adviser: Kwok-Keung Cheng.
Source: Dissertation Abstracts International, Volume: 73-04, Section: B, page: .
Thesis (Ph.D.)--Chinese University of Hong Kong, 2011.
Includes bibliographical references (leaves 176-188).
Electronic reproduction. Hong Kong : Chinese University of Hong Kong, [2012] System requirements: Adobe Acrobat Reader. Available via World Wide Web.
Electronic reproduction. [Ann Arbor, MI] : ProQuest Information and Learning, [201-] System requirements: Adobe Acrobat Reader. Available via World Wide Web.
Abstract also in Chinese.
APA, Harvard, Vancouver, ISO, and other styles
38

"BICMOS implementation of UAA 4802." Chinese University of Hong Kong, 1989. http://library.cuhk.edu.hk/record=b5886230.

Full text
APA, Harvard, Vancouver, ISO, and other styles
39

"Is there room for a second Hong Kong based airline: a look at the air transport industry in Hong Kong." Chinese University of Hong Kong, 1987. http://library.cuhk.edu.hk/record=b5885727.

Full text
APA, Harvard, Vancouver, ISO, and other styles
40

Pagliaruli-Marchetti, Amy M. "From mammies and Uncle Toms to gangsta's and ho's : a historic look at African Americans and their evolution in America's media and material culture /." 2006. http://www.consuls.org/record=b28237031.

Full text
Abstract:
Thesis (M.A.) -- Central Connecticut State University, 2006.
Thesis advisor: Prescott "... in partial fulfillment of the requirements for the degree of Master of Arts in Modern American History" Includes bibliographical references (leaves 146-151). Also available via the World Wide Web.
APA, Harvard, Vancouver, ISO, and other styles
41

"LTCC low phase noise voltage controlled oscillator design using laminated stripline resonators." 2002. http://library.cuhk.edu.hk/record=b5891066.

Full text
Abstract:
Cheng Sin-hang.
Thesis (M.Phil.)--Chinese University of Hong Kong, 2002.
Includes bibliographical references (leaves 90-92).
Abstracts in English and Chinese.
Chapter Chapter 1 --- Introduction --- p.1
Chapter Chapter 2 --- Theory of Oscillator Design --- p.4
Chapter 2.1 --- Open-loop approach --- p.4
Chapter 2.2 --- One-port approach --- p.6
Chapter 2.3 --- Two-port approach --- p.9
Chapter 2.4 --- Voltage controlled oscillator (VCO) design --- p.10
Chapter 2.4.1 --- Active device selection and biasing --- p.11
Chapter 2.4.2 --- Feedback circuit design --- p.15
Chapter 2.4.3 --- Frequency tuning circuit --- p.20
Chapter Chapter 3 --- Noise in Oscillators --- p.23
Chapter 3.1 --- Origin of phase noise --- p.23
Chapter 3.2 --- Impact of phase noise in communication system --- p.28
Chapter 3.3 --- Phase noise consideration in VCO design --- p.30
Chapter Chapter 4 --- Low Temperature Co-Fired Ceramic --- p.31
Chapter 4.1 --- LTCC process --- p.31
Chapter 4.1.1 --- LTCC fabrication process --- p.32
Chapter 4.1.2 --- LTCC materials --- p.34
Chapter 4.1.3 --- Advantages of LTCC technology --- p.35
Chapter 4.2 --- Passive components realization in LTCC --- p.37
Chapter 4.2.1 --- Capacitor --- p.37
Chapter 4.2.2 --- Inductor --- p.42
Chapter Chapter 5 --- High-Q LTCC Resonator Design --- p.47
Chapter 5.1 --- Definition of Q-factor --- p.47
Chapter 5.2 --- Stripline --- p.50
Chapter 5.3 --- Power losses --- p.52
Chapter 5.4 --- Laminated stripline resonator design --- p.53
Chapter 5.4.1 --- λ/4 resonator structure --- p.57
Chapter 5.4.2 --- Meander-line resonator structure --- p.60
Chapter 5.4.3 --- Bi-metal-layer resonator structure --- p.63
Chapter Chapter 6 --- LTCC Voltage Controlled Oscillator Design --- p.67
Chapter 6.1 --- Circuit design --- p.67
Chapter 6.2 --- Output filter --- p.68
Chapter 6.3 --- Embedded capacitor --- p.71
Chapter 6.4 --- VCO layout and simulation --- p.72
Chapter Chapter 7 --- Experimental Setup and Results --- p.77
Chapter 7.1 --- Measured Result: LTCC resonators --- p.77
Chapter 7.1.1 --- Experimental results --- p.79
Chapter 7.2 --- Measured results: LTCC voltage controlled oscillators --- p.83
Chapter Chapter 8 --- Conclusion and Future Work --- p.88
Reference List --- p.90
Appendix A: TRL calibration method --- p.93
Appendix B: Q measurement --- p.103
Appendix C: Q-factor extraction program listing --- p.109
Chapter 1. --- Function used to calculate Q from s-parameter --- p.109
Chapter 2. --- Function used to calculate Q from z-parameter --- p.111
APA, Harvard, Vancouver, ISO, and other styles
42

"Design and implementation of fully integrated low-voltage low-noise CMOS VCO." 2002. http://library.cuhk.edu.hk/record=b5891102.

Full text
Abstract:
Yip Kim-fung.
Thesis (M.Phil.)--Chinese University of Hong Kong, 2002.
Includes bibliographical references (leaves 95-100).
Abstracts in English and Chinese.
Abstract --- p.I
Acknowledgement --- p.III
Table of Contents --- p.IV
Chapter Chapter 1 --- Introduction --- p.1
Chapter 1.1 --- Motivation --- p.1
Chapter 1.2 --- Objective --- p.6
Chapter Chapter 2 --- Theory of Oscillators --- p.7
Chapter 2.1 --- Oscillator Design --- p.7
Chapter 2.1.1 --- Loop-Gain Method --- p.7
Chapter 2.1.2 --- Negative Resistance-Conductance Method --- p.8
Chapter 2.1.3 --- Crossed-Coupled Oscillator --- p.10
Chapter Chapter 3 --- Noise Analysis --- p.15
Chapter 3.1 --- Origin of Noise Sources --- p.16
Chapter 3.1.1 --- Flicker Noise --- p.16
Chapter 3.1.2 --- Thermal Noise --- p.17
Chapter 3.1.3 --- Noise Model of Varactor --- p.18
Chapter 3.1.4 --- Noise Model of Spiral Inductor --- p.19
Chapter 3.2 --- Derivation of Resonator --- p.19
Chapter 3.3 --- Phase Noise Model --- p.22
Chapter 3.3.1 --- Leeson's Model --- p.23
Chapter 3.3.2 --- Phase Noise Model defined by J. Cranincks and M Steyaert --- p.24
Chapter 3.3.3 --- Non-linear Analysis of Phase Noise --- p.26
Chapter 3.3.4 --- Flicker-Noise Upconversion Mechanism --- p.31
Chapter 3.4 --- Phase Noise Reduction Techniques --- p.33
Chapter 3.4.1 --- Conventional Tank Circuit Structure --- p.33
Chapter 3.4.2 --- Enhanced Q tank circuit Structure --- p.35
Chapter 3.4.3 --- Tank Circuit with parasitics --- p.37
Chapter 3.4.4 --- Reduction of Up-converted Noise --- p.39
Chapter Chapter 4 --- CMOS Technology and Device Modeling --- p.42
Chapter 4.1 --- Device Modeling --- p.42
Chapter 4.1.1 --- FET model --- p.42
Chapter 4.1.2 --- Layout of Interdigitated FET --- p.46
Chapter 4.1.3 --- Planar Inductor --- p.48
Chapter 4.1.4 --- Circuit Model of Planar Inductor --- p.50
Chapter 4.1.5 --- Inductor Layout Consideration --- p.54
Chapter 4.1.6 --- CMOS RF Varactor --- p.55
Chapter 4.1.7 --- Parasitics of PMOS-type varactor --- p.57
Chapter Chapter 5 --- Design of Integrated CMOS VCOs --- p.59
Chapter 5.1 --- 1.5GHz CMOS VCO Design --- p.59
Chapter 5.1.1 --- Equivalent circuit model of differential LC VCO --- p.59
Chapter 5.1.2 --- Reference Oscillator Circuit --- p.61
Chapter 5.1.3 --- Proposed Oscillator Circuit --- p.62
Chapter 5.1.4 --- Output buffer --- p.63
Chapter 5.1.5 --- Biasing Circuitry --- p.64
Chapter 5.2 --- Spiral Inductor Design --- p.65
Chapter 5.3 --- Determination of W/L ratio of FET --- p.67
Chapter 5.4 --- Varactor Design --- p.68
Chapter 5.5 --- Layout (Cadence) --- p.69
Chapter 5.6 --- Circuit Simulation (SpectreRF) --- p.74
Chapter Chapter 6 --- Experimental Results and Discussion --- p.76
Chapter 6.1 --- Measurement Setup --- p.76
Chapter 6.2 --- Measurement results: Reference Oscillator Circuit --- p.81
Chapter 6.2.1 --- Output Spectrum --- p.81
Chapter 6.2.2 --- Phase Noise Performance --- p.82
Chapter 6.2.3 --- Tuning Characteristic --- p.83
Chapter 6.2.4 --- Microphotograph --- p.84
Chapter 6.3 --- Measurement results: Proposed Oscillator Circuit --- p.85
Chapter 6.3.1 --- Output Spectrum --- p.85
Chapter 6.3.2 --- Phase Noise Performance --- p.86
Chapter 6.3.3 --- Tuning Characteristic --- p.87
Chapter 6.3.4 --- Microphotograph --- p.88
Chapter 6.4 --- Comparison of Measured Results --- p.89
Chapter 6.4.1 --- Phase Noise Performance --- p.89
Chapter 6.4.2 --- Tuning Characteristic --- p.90
Chapter Chapter 7 --- Conclusion and Future Work --- p.93
Chapter 7.1 --- Conclusion --- p.93
Chapter 7.2 --- Future Work --- p.94
References --- p.95
Author's Publication --- p.100
Appendix A --- p.101
Appendix B --- p.104
Appendix C --- p.106
APA, Harvard, Vancouver, ISO, and other styles
43

Tsai, Ming-che, and 蔡名哲. "Look for the Essential Design, Strive to Do the Top Priorities-the Ethnic Identity and Socia Memories in the Manchu Book “Record of the words of One Hundred and Twenty Old Men ”." Thesis, 2010. http://ndltd.ncl.edu.tw/handle/25812612222537773222.

Full text
APA, Harvard, Vancouver, ISO, and other styles
44

Schmieder, Martin [Verfasser]. "New aspects of the Middle-Late Triassic terrestrial impact cratering record : 40Ar/39Ar dating of the Rochechouart (France), Manicouagan (Canada), and Paasselkä (Finland) impact structures, paleoenvironmental considerations, and a critical look at the Late Triassic multiple impact theory / by Martin Schmieder." 2010. http://d-nb.info/1007475773/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography