To see the other types of publications on this topic, follow the link: Medida de descarga.

Dissertations / Theses on the topic 'Medida de descarga'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 25 dissertations / theses for your research on the topic 'Medida de descarga.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

Silva, Neto Jose Cupertino da. "Medida da densidade de atomos no estado metastavel em uma descarga de argonio." reponame:Repositório Institucional da UFSC, 1988. http://repositorio.ufsc.br/xmlui/handle/123456789/75474.

Full text
Abstract:
Dissertação (mestrado) - Universidade Federal de Santa Catarina. Centro de Ciencias Fisicas e Matematicas
Made available in DSpace on 2012-10-16T01:39:59Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-08T16:05:41Z : No. of bitstreams: 1 81776.pdf: 1442536 bytes, checksum: 9286cdcc76386af151e4ed5ae67bf84e (MD5)
A determinação da densidade de átomos metastáveis em uma descarga de coluna positiva de argônio é obtido medindo a absorção óptica. Para obtenção de tais medidas utilizou-se dois tubos de descarga elétrica de mesma dimensão e submetidos a pressões e correntes iguais, um funcionando como lâmpada e outro como célula de absorção. Com a montagem e considerando a auto-absorção na equação que relaciona a absorção com a densidade de átomos metastáveis, mostrou-se que esta última pode ser obtida sem que haja necessidade de medir a largura a meia altura das linhas da lâmpada e do plasma. São discutidos os limites de validade do método, em particular a pressões superiores a 10 torr, onde, além da auto-absorção, deve também ser considerado o alargamento das linhas por efeito de pressão. Finalmente, a título de verificação, medidas de absorção são feitas utilizando-se uma lâmpada Phillips de argônio permitindo que se encontre a largura de linhas da lâmpada. Os valores obtidos apresentam bom acordo com valores encontrados por outros autores.
APA, Harvard, Vancouver, ISO, and other styles
2

Nagashima, Haroldo Naoyuki. "Migração de carga espacial em copolímeros P(VDF/TrFE)." Universidade de São Paulo, 1992. http://www.teses.usp.br/teses/disponiveis/54/54132/tde-14012009-102720/.

Full text
Abstract:
Este trabalho apresenta um modelo teórico que procura explicar a origem de um pico anômalo de corrente, observado na fase faraeletrica do copolímero P(VDF/TrFE), nos processos de descarga. Quando uma voltagem tipo V(t) = Vo S(t) é aplicado em materiais isolantes, correntes elétricas observadas em medidas, de carga-descarga decaem aproximadamente com T-n e obedecem ao principio da superposição linear (PSL). Esse comportamento e também observado em polímeros dielétricos. Entretanto, nos processos de descarga, acima da temperatura de Curie do copolímero p (VDF/TrFE), surge um pico anomalo de corrente que viola, aparentemente, o (PSL). Apresentamos um modelo de migração de cargas de espaço em presença de armadilhas, que pode ser responsável pelo pico de corrente e que estaria superposta a corrente de descarga da absorção dielétrica, conforme o modelo, durante os processos de carga, impurezas extrínsecas seriam varridas, pelo campo, do volume da amostra e ficariam, preferencialmente, presas em armadilhas de superfície. Nos processos de descarga, essas cargas se deslocariam em direção ao interior da amostra, devido a repulsão Coulombiana. Esse mecanismo de condução gera um pico de corrente. A aplicação do modelo, permitiu-nos inferir valores de parâmetros como a mobilidade dos portadores de carga e o tempo de transito.
A model based on space charge migration to explain an anomalous electric current peak on films of P (VDF/TrFE) copolymer in its paraelectric phase is presented. In general step-voltage current measurements of insulating polymeric materials obey the Principle of Linear Super-position. However, an unexpected anomalous peak was observed in discharge currents in measurements performed with P (VDF/TrFE) above the Curie temperature. We have assumed that space charges were dragged from the bulk of the sample by the external field during the charge measurement, and trapped close to the surface of the sample in a region where the concentration of traps would be very high. Two methods were developed to calculate the magnitude of the current peak: I) assuming a given space charge distribution during the discharge measurement, and II) considering the movement of thin discrete layers of charge under the influence of the internal field.
APA, Harvard, Vancouver, ISO, and other styles
3

Brand, Anesio Boger. "Medida da temperatura em descargas N2+H2 usando o metodo de espectroscopia de emissão." reponame:Repositório Institucional da UFSC, 1991. http://repositorio.ufsc.br/xmlui/handle/123456789/75727.

Full text
Abstract:
Dissertação (mestrado) - Universidade Federal de Santa Catarina. Centro de Ciencias Fisicas e Matematicas
Made available in DSpace on 2012-10-16T03:53:32Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-08T17:02:04Z : No. of bitstreams: 1 84778.pdf: 1428063 bytes, checksum: f874a4d7fb70319dea2f05929061976d (MD5)
O estudo de descargas luminescentes no regime anormal tem merecido especial atenção devido a sua aplicabilidade nos processos de nitretação de superfícies metálicas. Um dos parâmetros importante a ser controlado no processo de nitretação é a temperatura do subtrato, por ser um fator determinante em reações químicas e processos de difusão. O nosso trabalho consiste em medir a "temperatura" rotacional dos estados N2+(B) e N2(C) do nitrogênio próxima ao cátodo, a partir da medida das intensidades relativas das linhas do espectro rotacional de emissão desses estados. As "temperaturas" rotacionais são comparadas com a temperatura do substrato que é determinada através de um termopar. É mostrado que a "temperatura" rotacional do estado N2+(B) é idêntica à temperatura do substrato exceto para descargas de nitrogênio puro a pressões superiores a 1,0 torr, enquanto que a "temperatura" rotacional do estado N2(C) é idêntica à temperatura do substrato, o que está de acordo com os resultados da literatura.
APA, Harvard, Vancouver, ISO, and other styles
4

Braun, Luci Fortunata Motter. "Medidas e interpretações de sinais optogalvânicos resolvidos no tempo." reponame:Biblioteca Digital de Teses e Dissertações da UFRGS, 2008. http://hdl.handle.net/10183/14859.

Full text
Abstract:
Neste trabalho apresentamos e discutimos os resultados obtidos investigando a dinâmica da geração do sinal optogalvânico (SOG) em dois tipos de descargas elétricas luminosas em argônio. Ambas as descargas operavam no regime subnormal que corresponde a região da curva tensão versus corrente (V x 1) onde a resistência dinâmica delas é negativa. As condições típicas de operação das duas descargas incluem: um potencial de 250 a 500 V através do tubo, uma corrente na descarga de 0,1 a 1 mA e uma pressão do gás de 400 a 600 Pa. Na descarga de eletrodos paralelos foram feitas as medidas do SOG excitando transições de um fóton no intervalo de 415 a 434 nm com um laser pulsado de 10 Hz e duração dos pulsos de nanosegundos. Verificamos que quando o regime de operação da descarga varia de normal para subnormal, o SOG muda da forma de um pulso para a de uma oscilação harmônica amortecida. Os resultados experimentais foram interpretados através de um modelo que representa a descarga de eletrodos paralelos como um transdutor opto eletrônico de segunda ordem. Um resultado importante desta análise é que, quando a descarga muda do regime normal para subnormal, a evolução temporal do SOG (independente de sua origem) é explicada modelando a descarga em termos de um circuito elétrico equivalente. A origem do SOG foi estudada na descarga de catodo oco através da interação com pulsos ultracurtos. As medidas do sinal optogalvânico intermodulado (SOGIM) na descarga de catodo oco envolveram a excitação de transições de um e dois fótons no intervalo de 760 a 776 nm usando um trem de par de pulsos de um laser de Ti-Safira de 76 MHz de taxa de repetição e duração dos pulsos de femtossegundos. Os SOGIM foram registrados mudando o atraso T entre os pulsos do par, para diferentes valores da duração temporal dos pulsos. A análise dos SOGIM foi feita para duas regiões de atrasos. Na região de atrasos grandes que corresponde a ITI > 500 fs, discutiu-se a dependência da magnitude do SOGIM com o comprimento de onda central e com a largura temporal do pulso laseI. Para região em torno do retardo zero, isto é ITI < 500 fs, analisou-se o seu perfil temporal. Constatamos que a magnitude do SOGIM para atrasos grandes, o qual chamamos de nível de fundo, dependia da ressonância entre a excitação laser e as transições de um fóton em 763,51, 772,37 e 772,43 nm e também do valor da largura espectral do pulso; mais especificamente, da convolução entre o espectro do laser e uma dessas transições de um fóton. Na análise do perfil temporal do SOGIM em torno de T = Overificamos que as medidas podiam ser cla..'3ssificadasespectralmente em dois grupos: o grupo dos sinais que não envolve a fotoionização e o grupo dos que envolve este processo. Para melhor entendermos as características dos SOGIM, recorremos a uma simulação numérica baseada no modelo de um átomo de 3 níveis interagindo com um trem de par de pulsos ultracurtos. O modelo teórico desenvolvido apresentou um bom acordo qualitativo com parte dos dados experimentais e se mostrou uma ferramenta útil para a análise e interpretação das medidas.
In this work we present and discuss the results obtained investigating the dynamics of the generation of the optogalvanic signal (OGS) in two types of electrical glow discharges in argon. Both discharges were operated at the subnormal regime which corresponds to the region of the volt age versus current (V x 1) curve where their dynamic resistance is negative. The typical conditions of operation for the two discharges include: a potential between 250 to 500 V across the tube, a current through the discharge of 0,1 to 1 mA, and a gas pressure of 400 to 600 Pa. In the discharge of parallel electrodes the OGS measures were performed exciting one photon transitions in the range of 415 to 434 nm with a 10 Hz pulsed laser with a pulse duration of nanoseconds. We noted that when the operation regime of the discharge varies from the normal to the subnormal one, the OGS will change its shape from a pulse to a damped harmonic oscillation. The experimental results were interpreted through a modeI that represents the discharge of parallel electrodes as a second order optoeletronic transducer. One important result of this analysis is that when the discharge changes from the normal regime to the subnormal one, the temporal evolution of the OGS (regardless of its origin) is explained modeling the discharge in terms of an electrical equivalent circuito The origin of the OGS was studied in the hollow cathode discharge through the interaction with ultrashort pulses. The measures of the intermodulated optogalvanic signal (IMOGS) in the hollow cathode discharge involved the excitation of one and two photon transitions in the range of 760 to 776 nm using a train of pair of pulses from a Ti-Sapphire laser of 76 MHz repetition rate and pulses with duration of femtoseconds. The IMOGS were recorded changing the delay 7 between the two pulses of the pair, for different values of the pulses time length. The analysis of the IMOGS was made for two regions of delays. In the region of major delays corresponding to 171> 500 fs, the dependence of the magnitude of IMOGS with the central wavelength and with the time width of the laser pulse was discussed. For the region around zero delay, that is 171 < 500 fs, his time profile was examined. We noted that the magnitude of IMOGS for major delays, which we named background leveI, depends on the resonance between the laser excitation and the one photon transitions at 763.51, 772.37 and 772.43 nm and aIso on the value of the spectral width of the pulse; more specifically, it depends on the convolution between the spectrum of the laser and one of those one photon transitions. In the analysis of the IMOGS temporal profile around the zero delay we verified that the measures could be spectrally classified into two groups: the group of signals that does not involve the photoionization and the group involving this processo To better understand the characteristics of IMOGS, we use a numerical simulation based on a 3 leveI modeI for the atom interacting with a train of ultrashort pair of pulses. The theoretical model developed presents a good qualitative agreement with the experimental data and was a useful tool for analysis and interpretation of the measures.
APA, Harvard, Vancouver, ISO, and other styles
5

Lima, Iara Batista de. "Medidas do primeiro coeficiente Townsend de ionização em gases inibidores de descargas." Universidade de São Paulo, 2014. http://www.teses.usp.br/teses/disponiveis/85/85131/tde-18062014-132035/.

Full text
Abstract:
No presente trabalho são apresentados resultados referentes ao primeiro coeficiente Townsend de ionização (α) no isobutano puro, para a faixa de campo elétrico reduzido (E/N) de 145 até194 Td. A configuração do aparato experimental consiste de uma configuração semelhante a uma RPC, com o anodo constituído por um vidro de elevada resistividade (2 x 1012 Ωcm) e um catodo metálico, ligado diretamente a um eletrômetro, onde fotoelétrons são produzidos pela incidência de um feixe de laser pulsado. O coeficiente α é determinado por meio da medição da corrente elétrica em regime de ionização primária e em regime de avalanche. Uma vez que, para o isobutano puro não há valores experimentais disponíveis na literatura, para a faixa de E/N analisada por este trabalho, os valores obtidos foram comparados com os resultados da simulação Magboltz 2. Os estudos incluíram a determinação do coeficiente α para diferentes taxas de repetição e intensidades do feixe de laser. Como a relação entre a carga rápida e a total relaciona-se com o primeiro coeficiente de Townsend, estudos relativos à contribuição iônica e eletrônica para a corrente média também foram realizados. Como existem poucos resultados disponíveis na literatura referentes às secções de choque de colisão e parâmetros de transporte para o isobutano é comum considerar os resultados de seu isômero estrutural: o n-butano. Assim, a fim de realizar uma análise comparativa, o coeficiente α foi determinado também para o n-butano.
In the present work, results concerning the first Townsend ionization coefficient (α) in pure isobutane within the density-normalized electric field (E/N) range of 145 to 194 Td are presented. The experimental setup consists of RPC-like cell with the anode made of a high resistivity glass (2 x 1012 Ωcm) and a metallic cathode, directly connected to an electrometer, on which photoelectrons are produced by the incidence of a pulsed laser beam. The α coefficient is determined by measuring the current under primary ionization and avalanche regime. Since for the E/N range covered by this work, there are no experimental values for pure isobutane available in the literature, the obtained values were compared with Magboltz 2 results. Our studies included the determination of α coefficient for different repetition rates and laser beam intensity. The ratio of the fast charge to the total charge is related to the first Townsend coefficient, so studies concerning the ionic and the electronic contribution to the average current were also performed. Since there are few results available in the literature for isobutane, concerning collisional cross section and electron transport parameters, is common to consider results from its structural isomer: n-butane. Thus, in order to perform a comparative analysis, the coefficient α was also determined for n-butane.
APA, Harvard, Vancouver, ISO, and other styles
6

LIMA, IARA B. de. "Medidas do primeiro coeficiente townsend de ionização em gases inibidores de descargas." reponame:Repositório Institucional do IPEN, 2014. http://repositorio.ipen.br:8080/xmlui/handle/123456789/10626.

Full text
Abstract:
Made available in DSpace on 2014-10-09T12:42:33Z (GMT). No. of bitstreams: 0
Made available in DSpace on 2014-10-09T14:02:06Z (GMT). No. of bitstreams: 0
Tese (Doutoramento)
IPEN/T
Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
APA, Harvard, Vancouver, ISO, and other styles
7

Rodrigo, Mor Armando. "Nueva metodología de la medida de descargas parciales en cables de alta tensión. Desarrollo de un sensor capacitivo de gran ancho de banda." Doctoral thesis, Universitat Politècnica de València, 2012. http://hdl.handle.net/10251/16271.

Full text
Abstract:
En la actualidad la medida de descargas parciales constituye una herramiento eficaz para el diagnóstico de fallos de aislamiento. La presente tesis está centrada en los diferentes métodos de ensayo de descargas parciales en cables de media y alta tensión. Principalmente se ha estudiado la influencia de los diferentes métodos de ensayo en la evaluación de la carga de los pulsos de descargas parciales en ensayos off-line (ensayos en lso que se saca el cable fuera de servicio). La tesis analiza las particularidades de los métodos convencionales, y de los nuevos métodos o métodos no convencionales. Los métodos convencionales, empleados desde los años 60 en laboratorios de alta tensión, emplean filtros paso-banda como herramienta para la evaluación de los pulsos de descargas parciales. Los métodos no convencionales emplean sensores con anchos de banda muy superiores a los métodos convencionales pues esto permite la localización de los pulsos por técnicas de reflectometría y el uso de herramientas matemáticas que ayudan a la identificación de los pulsos de descargas parciales. En esta tesis se proponen y comparan diferentes métodos de evaluación de carga para los métodos no convencionales, y se establecen los límites de la incertidumbre en dichas medidas en función del ancho de banda de los sensores y de la longitud de los pulsos de descargas parciales. La tesis aborda el análisis de los transformadores de corriente de alta frecuencia que comúnmente se emplean como sensores de descargas parciales para medidas acopladas por campo magnético, y el estudio de los sensores acoplados por campo eléctrico. La comparativa de ambos sensores permite extraer conclusiones acerca de los anchos de banda obtenidos, de la incertidumbre alcanzada para diferentes longitudes de pulso y métodos de evaluación de carga, y de la sensibilidad de los sistemas de medida que emplean estos sensores. Las medidas experimentales se han realizado empleando diferentes prototipos de sensores acoplados por
Rodrigo Mor, A. (2012). Nueva metodología de la medida de descargas parciales en cables de alta tensión. Desarrollo de un sensor capacitivo de gran ancho de banda [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/16271
Palancia
APA, Harvard, Vancouver, ISO, and other styles
8

Volpe, Ernesto Souza. "Estudo sobre coeficientes de descarga e dimensionamento de grelhas." Instituto Tecnológico de Aeronáutica, 2010. http://www.bd.bibl.ita.br/tde_busca/arquivo.php?codArquivo=2805.

Full text
Abstract:
Com a crescente competitividade no setor aeronáutico, todo ganho, por menor que seja, em desempenho de aeronave é extremamente importante para seu sucesso comercial. O correto dimensionamento de entradas e saídas de ar leva a um ganho competitivo de uma aeronave em relação à outra. Isto se deve a grande presença de entradas e saídas de ar, como grelhas, scoops e as desenvolvidas pela NACA (National Advisory Committee for Aeronautics posteriormente todos os recursos foram transferidos para National Aeronautics and Space Administration - NASA) presentes em cada aeronave. Buscando obter o dimensionamento otimizado de grelhas utilizadas em sistemas aeronáuticos, alguns parâmetros de dimensionamento para grelhas de exaustão de ar foram obtidos via CFD (sigla do inglês para Computational Fluid Dynamics) para três tipos de grelhas: flush (altura da grelha nivelada com seu plano de instalação) com defletor reto, flush com defletor curvo e não flush com defletor curvo. Os parâmetros de dimensionamento das três grelhas analisadas no presente trabalho foram: coeficiente de descarga, razão de vazão mássica e coeficiente de pressão. Os resultados são apresentados para cada grelha analisada em função do número de Mach, altitude e vazão mássica. Um estudo de comparação com resultados experimentais, disponíveis na literatura, é também apresentado no presente trabalho. Os resultados apresentados nesta dissertação têm potencial para serem utilizados em um melhor dimensionamento de grelhas aeronáuticas em geral. Deve-se ressaltar que o presente trabalho não define o melhor tipo de grelha que deve ser utilizado para todas as funções, e sim apresenta alguns parâmetros que devem ser utilizados para o dimensionamento otimizado de uma grelha de exaustão de ar para o cumprimento de sua função.
APA, Harvard, Vancouver, ISO, and other styles
9

Mejía, Hidalgo Gabriel Santiago. "Supervisión de transporte de fluidos hidrocarburos en operaciones marítimas de carga y descarga." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2015. https://hdl.handle.net/20.500.12672/12797.

Full text
Abstract:
El manejo de fluidos como los hidrocarburos en las labores de carga y descarga en los terminales portuarios, es una actividad que implica máximos niveles de seguridad por sus características de fluidos peligrosos y por representar alto valor económico, requiriéndose para ello la determinación exacta de la calidad y volúmenes, por lo que la supervisión de estas actividades es realizada por profesionales que reúnen características de las más altas competencias. Este perfil profesional es actualmente cubierto de modo satisfactorio por profesionales de diversas carreras de ingeniería, ya sea Química, Petroquímica o de Petróleo, cuya formación se enmarca dentro de las necesidades existentes. Estos profesionales tienen como objetivo específico, el de lograr la mayor eficiencia posible en las actividades de carga y descarga de los buques tanqueros, a ser efectuados en Terminales Marítimos y Amarraderos Multiboyas. El autor del presente trabajo monográfico tiene como propósito presentar de manera pormenorizada dichas labores en concordancia con las más estrictas normas nacionales e internacionales. En los más de veinte años de trabajo profesional en actividades de Supervisión de Transporte de estos fluidos presenta sus experiencias y aportes profesionales en la mejora del manejo técnico y documentario, que ha permitido de alguna manera mayor eficiencia con impactos favorables en la seguridad y en los aspectos económicos de las empresas involucradas, los mismos que son materia de detalle en la presente monografía.
Trabajo de suficiencia profesional
APA, Harvard, Vancouver, ISO, and other styles
10

Camargo, Alexandre Menezes de. "Desenvolvimento de resistor shunt para medidas de correntes impulsivas em especial para aquelas oriundas de descargas atmosféricas." Universidade de São Paulo, 2003. http://www.teses.usp.br/teses/disponiveis/18/18133/tde-18022016-093617/.

Full text
Abstract:
Este trabalho objetivou a construção de um resistor shunt dedicado a medir correntes impulsivas com valores de 2 kA a 100 kA. Esse resistor possui características gerais similares aos resistores shunt coaxiais convencionais descritos na literatura. No entanto, ele difere dos demais já desenvolvidos, por apresentar inúmeras inovações tecnológicas. Quando comparado com um resistor shunt Haefely® padrão, apresentou excelente estabilidade em toda a faixa de freqüência requerida, até 10 MHz, bem como, excelente resposta temporal.
The aim of this work was to construct a shunt resistor to measure impulsive currents with values from 2 kA to 100 kA, with general features similar to conventional coaxial resistors as described in the literature. However, it differs from resistors already developed because it shows many offers technological innovations. When compared to a should stand Haefely® shunt resistor, it presented great stability in all required frequency band to 10 MHz, as well as excellent temporal response.
APA, Harvard, Vancouver, ISO, and other styles
11

Vivaldini, Túlio Cearamicoli. "Medidas de velocidade de arrastamento de elétrons em gases inibidores de descargas pelo método de Townsend pulsado." Universidade de São Paulo, 2014. http://www.teses.usp.br/teses/disponiveis/85/85131/tde-10072014-155715/.

Full text
Abstract:
O deslocamento de elétrons em gases pode ser caracterizado por grandezas macroscópicas tais como a velocidade de arrastamento, taxa de ionização, primeiro coeficiente de Townsend e os coeficientes de difusão longitudinal e transversal, que são denominados de parâmetros de transporte. Esses parâmetros são importantes já que permitem a validação das secções de choque de colisões de elétrons com as moléculas do gás, contribuem com informações para modelos de descargas automantidas e são importantes para o desenvolvimento de novos detectores gasosos. Neste trabalho são apresentados os resultados de velocidade de arrastamento (W), taxa de ionização (Ri) e do primeiro coeficiente Townsend de ionização (α), para o isobutano e n-butano em função do campo elétrico reduzido efetivo no intervalo de 130 a 180 Td, obtidos utilizando a técnica de Townsend pulsada. Em nosso aparato, os elétrons primários são gerados a partir da incidência no catodo de um curto pulso de laser e são acelerados em direção ao anodo por meio de um campo elétrico uniforme. O sinal elétrico proveniente do deslocamento desses elétrons é digitalizado por um osciloscópio e a partir do ajuste de uma função modelo à forma do sinal elétrico, determinam-se os parâmetros de transporte. Os resultados obtidos para o isobutano e n-butano foram comparados com os valores da simulação Magboltz 2-versão 8.6 em razão da escassez de dados na literatura para esses gases na região de campo elétrico reduzido estudada.
The electron swarm can be characterized by macroscopic quantities such as the drift velocity, ionization rate, first Townsend ionization coefficient and the longitudinal and transverse diffusion coefficients, so called transport parameters. These parameters are important since they allow the validation of electron collisional cross section with gas molecules, contribute for self-sustained discharge models and are important for gaseous detectors development. In the present work the results of electron drift velocity (W), ionization rate (Ri) and first Townsend coefficient (α) as a function of the reduced electric field for isobutane and n-butane by the means of pulsed Townsend technique are presented. In our experimental setup, the primary electrons are liberated by the irradiation of a short laser pulse at the cathode and are accelerated towards the anode through a uniform electric field. The electron movements induce signals that are digitalized and the fitting of a model function to their waveforms provides the transport parameters. The results obtained for isobutane and n-butane were compared with Magboltz 2-version 8.6 values, since there are few data in the literature for these gases for effective reduced electric field ranging from 130 to 180 Td.
APA, Harvard, Vancouver, ISO, and other styles
12

VIVALDINI, TULIO C. "Medidas de velocidade de arrastamento de elétrons em gases inibidores de descargas pelo método de townsend pulsado." reponame:Repositório Institucional do IPEN, 2014. http://repositorio.ipen.br:8080/xmlui/handle/123456789/10629.

Full text
Abstract:
Made available in DSpace on 2014-10-09T12:42:34Z (GMT). No. of bitstreams: 0
Made available in DSpace on 2014-10-09T14:01:33Z (GMT). No. of bitstreams: 0
Tese (Doutoramento)
IPEN/T
Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
APA, Harvard, Vancouver, ISO, and other styles
13

LEAL, Adônis Ferreira Raiol. "Análise de sensores de descargas atmosféricas: protótipo de um detector de raios com estimativa de densidade de raios para região amazônica utilizando PSoC." Universidade Federal do Pará, 2014. http://repositorio.ufpa.br/jspui/handle/2011/9241.

Full text
Abstract:
Submitted by Hellen Luz (hellencrisluz@gmail.com) on 2017-10-03T18:21:28Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AnaliseSensoresDescargas.pdf: 11724147 bytes, checksum: 8ee5f4831d064a9418414ffbd371fbbc (MD5)
Rejected by Edisangela Bastos (edisangela@ufpa.br), reason: on 2017-10-10T17:03:38Z (GMT)
Submitted by Hellen Luz (hellencrisluz@gmail.com) on 2017-10-16T14:26:53Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AnaliseSensoresDescargas.pdf: 11724147 bytes, checksum: 8ee5f4831d064a9418414ffbd371fbbc (MD5)
Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-11-13T16:21:47Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AnaliseSensoresDescargas.pdf: 11724147 bytes, checksum: 8ee5f4831d064a9418414ffbd371fbbc (MD5)
Made available in DSpace on 2017-11-13T16:21:47Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AnaliseSensoresDescargas.pdf: 11724147 bytes, checksum: 8ee5f4831d064a9418414ffbd371fbbc (MD5) Previous issue date: 2014-02-24
CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico
Este trabalho propõe o projeto de um protótipo de um sensor de descargas atmosféricas, que irá; contabilizar o número de descargas detectadas, calcular a densidade de raios para a área de atuação do sensor e estimar o pico da variação do campo elétrico para o instante de ocorrência da descarga. Um estudo sobre a eletricidade atmosférica, tipos de raios, emissão de ondas eletromagnéticas durante tempestades, tipos de sensores eletromagnéticos e redes de detecção de raios deram subsídio para o projeto do protótipo desenvolvido. O protótipo é constituído por duas antenas, uma antena Loop e uma antena Flat plate, e por circuitos eletrônicos, os quais são implementados em sua maioria no dispositivo PSoC (Programmable System-on-Chip), que trabalha com sinais analógicos e digitais e ainda conta com uma CPU para realizar o processamento destes sinais. A validação dos dados obtidos e a estimativa da área de abrangência do sensor, foram baseados em dados da rede STARNET (Sferics Timing And Ranging NETwork). O protótipo foi idealizado para ser de baixo custo, ter uma interface simples e poder ser instalado na região amazônica.
This work proposes the design of a prototype for detect lightning, which will, count the number of lightning detected, calculate the density of lightning to the area of operation of the sensor and to estimate the peak of the variation of the electric field for the instant occurrence of discharge. A study of atmospheric electricity, types of lightning, emission of electromagnetic waves during the occurrence of the lightning , types of electromagnetic sensors and lightning detection networks gave subsidy to the design of the prototype . The prototype consists of two antennas, one loop antenna and a flat plate antenna , and electronic circuits , these electronic circuits are implemented mostly in PSoC device ( Programmable System -on - Chip ) , which is a relatively new technology that works with analog and digital signals and also has a CPU to perform the processing of these signals . The validation of the data obtained and estimated coverage area of the sensor, were based on data from STARNET network (sferics Timing And Ranging NETwork). The prototype was designed to be low cost, have a simple and straightforward interface and can be installed in the Amazon region.
APA, Harvard, Vancouver, ISO, and other styles
14

VILHENA, Paulo Roberto Moutinho de. "Sistema para detecção, localização e monitoramento de descargas parciais em estatores de hidrogeradores." Universidade Federal do Pará, 2015. http://repositorio.ufpa.br/jspui/handle/2011/7745.

Full text
Abstract:
Submitted by camilla martins (camillasmmartins@gmail.com) on 2017-02-21T16:55:41Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_SistemaDeteccaoLocalizacao.pdf: 3882901 bytes, checksum: 704c5396d2a1a1048e29301da59eb483 (MD5)
Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-02-22T15:53:25Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_SistemaDeteccaoLocalizacao.pdf: 3882901 bytes, checksum: 704c5396d2a1a1048e29301da59eb483 (MD5)
Made available in DSpace on 2017-02-22T15:53:25Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_SistemaDeteccaoLocalizacao.pdf: 3882901 bytes, checksum: 704c5396d2a1a1048e29301da59eb483 (MD5) Previous issue date: 2015-11-30
Paradas de máquinas não planejadas causadas por falhas na isolação elétrica de equipamentos do sistema elétrico de potência são um grande problema, pois contabilizam elevadas perdas para planta e comprometem os indicadores de desempenho devido extenso período de parada da unidade geradora necessário para restauração da função geração. A fim de solucionar esse problema, vários pesquisadores e estudiosos da área de grandes máquinas rotativas descobriram que estas falhas estavam frequentemente relacionadas com o aumento do nível de descargas parciais da isolação elétrica da máquina. As ocorrências das DP nos sistemas isolantes dos equipamentos de alta tensão são sintomas de fragilidade na sua suportabilidade dielétrica, cuja evolução pode ocasionar graves consequências para o equipamento. Em virtude dessas consequências, a avaliação do estado operativo do enrolamento estatórico, por meio do sistema de medição de DP on line proposto nesta tese apresenta estratégias para aumentar a confiabilidade das medições. Como sensor de DP, foi sugerido usar acoplador direcional eletromagnético de microfita capaz de detectar o sinal com maior largura de banda na faixa UHF, comparado com os sensores tradicionais existentes. O desenvolvimento e a implementação do simulador virtual de DP decorreu da necessidade de se ter exemplos de sinais que permitissem testar algumas técnicas de processamento de sinais DP. O principal resultado da tese é o sistema de medição de DP (denominado SIM_DP) que inclui sensor, sistema de aquisição de dados, software de processamento de sinais de DP e de análise dos resultados. Ao estudar a propagação do sinal em uma barra estatórica foi possível desenvolver uma nova metodologia baseada em análise espectral para localização de DP. Por meio da estrutura montada em laboratório, foi possível validar o sistema SIM_DP o que favoreceu a análise crítica do fenômeno DP. Por fim foram analisados dados reais de medições de DP em campo e correlação das DP com vibrações mecânicas. Os resultados do trabalho contribuíram para um diagnóstico mais preciso do fenômeno. Os resultados da tese têm sido aprimorados em laboratório e em campo produzindo novos: implementação de novos ensaios em laboratório como envelhecimento acelerado de barras, novos sensores não invasivos como antenas capazes de medir descargas parciais e novas técnicas empregadas na análise e diagnóstico dos fenômenos relacionados com DP que serão apresentadas em trabalhos futuros.
Stops machines unplanned caused by faults in the electrical insulation of the power electric system equipment is a big problem, because account for high losses to plan and undertake performance indicators due long stop period generating unit necessary for the generation function restoration. In order to solve this problem, many researchers and scholars in the field of large rotating machines found that these failures were often related to the increased level of partial discharges (PDs) of electrical insulation of the machine. Occurrences of PDs in insulating systems of high voltage equipment are symptoms of weakness in their dielectric withstand, whose evolution can cause serious consequences for the equipment. Because of these consequences, the evaluation of the operating status of the stator winding through the on line PDs measurement system proposed in this thesis presents strategies to increase the reliability of the measurements. As PDs sensor, it has been suggested to use electromagnetic microstrip directional coupler can detect the signal with the highest bandwidth in the UHF band, compared to existing traditional sensors. The development and implementation of virtual simulator PDs caused by the need of having Examples of signals that allow testing some PDs signal processing techniques. The main result of this thesis is the DP measurement system (called SIM_DP) including sensor, data acquisition system, PDs signal processing software and analysis of results. By studying the propagation of the signal in a stator bar was possible to develop a new methodology based on spectral analysis for PDs location. Through the structure created in the laboratory, it was possible to validate the SIM_DP system which favored the review of the PDs phenomenon. Finally actual data were analyzed for DP measurements in the field and correlation of PDs with mechanical vibration. The results of the work contributed to a more accurate diagnosis of the phenomenon. The results of the thesis have been improved in laboratory and field producing new: implementation of new laboratory tests as Voltage Endurance Test (VET), new non-invasive sensors such as antennas capable of measuring partial discharges and new techniques used in the analysis and diagnosis of related DP phenomena which will be presented in future work.
APA, Harvard, Vancouver, ISO, and other styles
15

Ridenti, Marco Antonio. "Desenvolvimento de sistema de aquisição e tratamento de dados para medidas de parâmetros de transporte de elétrons em gases." Universidade de São Paulo, 2010. http://www.teses.usp.br/teses/disponiveis/43/43134/tde-29062010-142535/.

Full text
Abstract:
Esta dissertação descreve um experimento de Townsend pulsado cuja finalidade foi obter experimentalmente parâmetros de transporte de elétrons em gases, em particular em nitrogênio e isobutano, em uma faixa de campo elétrico reduzido entre 130 Td e 210 Td. Os parâmetros de transporte obtidos foram a velocidade média do centro de massa da nuvem eletrônica, a taxa de ionização e o coeficiente de ionização (primeiro coeficiente de Townsend). Essas grandezas foram determinadas a partir da análise do sinal eletrônico induzido pelos elétrons em deslocamento entre dois eletrodos de placas paralelas. Para efetuar essa análise, foi desenvolvido um modelo que relaciona a dinâmica dos elétrons no meio gasoso com o sinal induzido. Esse modelo permitiu a dedução de uma função explícita do tempo e de parâmetros relacionados com os parâmetros físicos, que foram estimados por meio do ajuste da função aos resultados experimentais pelo método dos mínimos quadrados. Além do método de análise, este trabalho descreve um código computacional de aquisição e controle, especialmente desenvolvido para integrar as diversas operações de controle instrumental e aquisição de dados. Foram realizadas várias séries de medições nas mesmas condições e verificou-se a repetitibilidade dos resultados. Os parâmetros de transporte em nitrogênio reproduziram os resultados da literatura e de cálculos teóricos dentro dos limites de erro dos resultados experimentais. No caso do isobutano, cujos parâmetros de transporte em elétrons são escassos na literatura, verificou-se que a estimativa do coeficiente de ionização é consistente com os resultados da literatura baseados em medições em um intervalo de campo elétrico reduzido mais elevado.
This thesis describes a pulsed Townsend experiment whose purpose was to obtain experimentally the transport parameters of electron in gases, particularly nitrogen and isobutane, within a range of reduced electric field between 130 Td and 210 Td. The transport parameters obtained were the average speed of center of mass of the electron cloud, the ionization rate and ionization coefficient (first Townsend coefficient). These quantities were obtained from the analysis of the electronic signal induced by electrons moving between two parallel plate electrodes. To perform this analysis, we developed a model that relates the dynamics of electrons in gaseous medium with the induced signal. This model allowed the deduction of an explicit function of time and parameters related to the physical parameters, which were estimated by fitting the function to the experimental results by the method of least squares. Besides the method of analysis, this paper describes a computer program especially designed to integrate the various processes of instrumental control and data acquisition. We performed several sets of measurements under the same conditions and verified the repeatability of results. The transport parameters in nitrogen reproduced the results of the literature and theoretical calculations within the error limits of the experimental results. In the case of isobutane, whose electron transport parameters have been poorly studied, it was found that the estimation of ionization coefficient agrees well with the literature results based on measurements in a range of higher reduced electric field.
APA, Harvard, Vancouver, ISO, and other styles
16

Gomes, Sidcley Pereira. "Localização de Fontes de Descargas Generalizadas em Pacientes com Epilepsia Mioclônica Juvenil." Universidade Federal do Maranhão, 2010. http://tedebc.ufma.br:8080/jspui/handle/tede/441.

Full text
Abstract:
Made available in DSpace on 2016-08-17T14:53:09Z (GMT). No. of bitstreams: 1 Sidcley Pereira Gomes.pdf: 4576085 bytes, checksum: 5969f56106d77776c17330c476ba26de (MD5) Previous issue date: 2010-05-28
One important information for the classification of epilepsy is the cortical localization of the discharges source. Juvenile myoclonic epilepsy (JME) is an idiopathic generalized epilepsy (IGE) that typically presents generalized tonic-clonic, myoclonic, or absence seizures, or a combination of these. In typical cases of JME, the seizures are usually bilateral and symmetric, and EEG shows generalized interictal epileptiform discharges and a generalized seizure pattern that also is bilaterally synchronous. Despite of the generalized pattern of this type of epilepsy, there are some electroencephalographic and clinical features that suggest focal origin for the discharges. In this work, EEG recordings of six patients were analyzed in order to find evidences for this cortical origin in JME. The analysis of the signals was based on independent component analysis (ICA) for separating epileptiform discharges from artifacts and other brain sources; then the discharge components were used to spatially localize its source. In the six patients the dipole sources were localized mainly in the frontal region, what suggests an important participation of the frontal lobe for this kind of epilepsy.
Uma informação importante para a classificação da epilepsia é a localização cortical das suas fontes de descargas. A epilepsia mioclônica juvenil (EMJ) é uma epilepsia generalizada idiopática (EIG), que tipicamente apresenta crises tônico-clônicas, mioclônicas , crises de ausênica ou uma combinação destas. Em casos típicos de EMJ, as crises são geralmente bilaterais e simétricas, e o EEG mostra descargas epileptiformes interictais generalizadas em um padrão geralmente sincrônico. A despeito dos padrões generalizados deste tipo de epilepsia, há algumas características eletroencefalográficas e clínicas que sugerem uma origem focal para estas descargas. Neste trabalho, os registros de EEG de seis pacientes foram analisados, afim de encontrar evidências para uma origem cortical em EMJ. O processamento dos sinais foi baseado na técnica de análise de componentes independentes (ICA), com a finalidade de separar descargas epileptiformes de artefatos e de outras fontes cerebrais. Após esse processo, as componentes de descargas foram usadas para localizar espacialmente suas fontes. Em seis pacientes, as fontes dipolo foram localizadas principalmente nas regiões frontais, o que sugere uma importante participação do lobo frontal para esse tipo de epilepsia.
APA, Harvard, Vancouver, ISO, and other styles
17

ALVES, Medillin Pereira. "Caracterização de padrões de descargas parciais em hidrogeradores utilizando técnicas de inteligência computacional." Universidade Federal do Pará, 2015. http://repositorio.ufpa.br/jspui/handle/2011/8038.

Full text
Abstract:
Submitted by camilla martins (camillasmmartins@gmail.com) on 2017-03-28T14:26:26Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_CaracterizacaoPadroesDescargas.pdf: 2325678 bytes, checksum: 6b9320d0926975fccc3a7fc2af19d0d4 (MD5)
Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-03-28T16:10:17Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_CaracterizacaoPadroesDescargas.pdf: 2325678 bytes, checksum: 6b9320d0926975fccc3a7fc2af19d0d4 (MD5)
Made available in DSpace on 2017-03-28T16:10:17Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_CaracterizacaoPadroesDescargas.pdf: 2325678 bytes, checksum: 6b9320d0926975fccc3a7fc2af19d0d4 (MD5) Previous issue date: 2015-09-24
CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico
Esta dissertação apresenta os experimentos com aplicações de técnicas de Inteligência computacional para caracterização de descargas parciais em hidrogeradores. A classificação das descargas parciais contribui para uma análise prévia de problemas e permite a manutenção preditiva nas máquinas, reduzindo a possibilidade de falhas nas mesmas. Os dados foram coletados de modo online (máquina em operação) na Usina Hidrelétrica de Tucuruí, sendo observados os padrões de descarga interna, de laminação e entre barras. O software IMA-DP, desenvolvido em parceria entre Eletronorte e Cepel, permitiu que esses dados fossem medidos e registrados de maneira rápida, e organizados através dos mapas PRPD (Phase Resolved Partial Discharges). As técnicas de binarização, ANOVA (Analisys of Variance), ACI (Análise de Componentes Independentes) e ACP (Análise de Componentes Principais) foram aplicadas aos sinais para adequar os mesmos ao uso das técnicas de inteligência computacional. O trabalho foi desenvolvido no ambiente IPython usando a biblioteca scikit-learn, a qual possui eficientes algoritmos de inteligência. Os experimentos foram realizados fazendo-se uso das técnicas: KNN (K-Nearest Neighbors.), Floresta Randômica e MVS (Máquinas de Vetores de Suporte). Tais técnicas apresentaram bons resultados com os experimentos realizados, destacando-se aqueles obtidos para MVS que apresentaram os melhores resultados, atingindo uma acurácia de 96.07%, devido possuir mecanismos de seleção das principais variáveis durante o processo de treinamento.
This master's thesis presents the experiments with applications of computational intelligence techniques for the characterization of partial discharges in hydrogenerators. The classification of the partial discharge contributes to a prior analysis problems and allows predictive maintenance on machinery, reducing the possibility of failures in them. Data were collected online mode (operation machine) in the Tucuruí Hydroelectric Power Plant, observed the internal discharge standards, delamination and between bars. The IMA-DP software, developed in partnership with Eletronorte and Cepel, allowed these data were measured and recorded quickly, and organized through PRPD maps (Phase resolved Partial Discharges). Binarization techniques, ANOVA (Analisys of Variance), ICA (Independent Component Analysis) and PCA (Principal Component Analysis) were applied to the signals to adapt them to the use of computational intelligence techniques. The study was developed in IPython environment using scikit-learn library, which has efficient intelligence algorithms. The experiments were performed making use of techniques: KNN (K-Nearest Neighbors), Random Forest and MVS (Support Vector Machines). Such techniques showed good results with the experiments, highlighting those obtained for MVS that showed the best results, achieving an accuracy of 96.07%, due possess selection mechanisms of the main variables during the training process.
APA, Harvard, Vancouver, ISO, and other styles
18

BRASIL, Fernando de Souza. "Estudo experimental de técnicas de medição de descargas parciais nos enrolamentos estatóricos de hidrogeradores." Universidade Federal do Pará, 2013. http://repositorio.ufpa.br/jspui/handle/2011/4612.

Full text
Abstract:
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2014-01-13T19:23:18Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_EstudoExperimentalTecnicas.pdf: 7117519 bytes, checksum: fb5695be8f32467589254855458aa5bd (MD5)
Approved for entry into archive by Ana Rosa Silva(arosa@ufpa.br) on 2014-01-16T14:10:58Z (GMT) No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_EstudoExperimentalTecnicas.pdf: 7117519 bytes, checksum: fb5695be8f32467589254855458aa5bd (MD5)
Made available in DSpace on 2014-01-16T14:10:58Z (GMT). No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_EstudoExperimentalTecnicas.pdf: 7117519 bytes, checksum: fb5695be8f32467589254855458aa5bd (MD5) Previous issue date: 2013
Este trabalho tem como objetivo geral analisar experimentalmente técnicas para medição de descargas parciais nos enrolamentos estatóricos de hidrogeradores. Para atingir o objetivo proposto, primeiramente foi realizado um estudo bibliográfico sobre como é a estrutura dos enrolamentos do estator, com ênfase na isolação elétrica, assim como os conceitos de descargas parciais e técnicas empregadas para medição em hidrogeradores. Em seguida, foi montado em laboratório um arranjo experimental para o estudo das técnicas de medição de descargas parciais nos enrolamentos do estator utilizando seis acopladores diferentes, sendo quatro acopladores capacitivos convencionais de 80, 220, 500 e 1000 pF, e dois sistemas experimentais, uma antena SSC fabricada com microfita e um cabo coaxial RG 58, desencapado, utilizado como antena. A avaliação da sensibilidade destes seis sistemas foi divida em duas etapas: primeiro foi analisada a resposta dos acopladores à aplicação de um sinal conhecido de calibração e, em seguida, foi analisada a resposta dos mesmos durante ensaios com alta tensão. Para aplicação de um sinal conhecido de calibração os acopladores capacitivos apresentaram maior sensibilidade em relação à antena e ao cabo coaxial. Já a resposta durante os ensaios com alta tensão mostrou que a sensibilidade da antena é maior que a do método convencional de medição de descargas parciais em hidrogeradores, baseado em acopladores capacitivos de 80 e 220 pF. Os resultados obtidos em laboratório mostraram que a medição de descargas parciais através da antena pode ser realizada de forma satisfatória na avaliação da condição operacional dos enrolamentos do estator de hidrogeradores, sem perda significativa de informação e com aumento significativo de sensibilidade na quantificação do fenômeno, cerca de duas vezes maior que a sensibilidade do acoplador de 220 pF e quatro vezes a do acoplador de 80 pF.
This paper aims at analyzing experimental techniques for partial discharges measuring in the stator windings of hydrogenerators. To reach the goal, first proposed a study of the literature on how the structure of the stator windings, with an emphasis on electrical insulation, as well as the concepts of partial discharges and techniques used for measuring in hydrogenerators. It was then mounted in a laboratory arrangement for studying techniques for measuring partial discharges in the stator winding using six different couplers, four conventional capacitive couplers 80, 220, 500 and 1000 pF, and two experimental systems, an antenna, ribbon coaxial cable and RG 58, bare used with the antenna function. The evaluation of the sensitivity of these six systems has been divided in two steps: first were analyzed the responses of couplers applying a known calibration signal, and then analyzed the response of the same high voltage during testing. For application of a known signal calibration the capacitive couplers showed greater sensitivity than antenna and coaxial cable. Already during the response tests showed that the High Voltage sensitivity of the antenna tape is larger than the conventional method of measuring partial discharges in hydro using capacitive couplers 80 and 220 pF. The results obtained in the laboratory showed that the measurement of partial discharges through the antenna tape can be performed satisfactorily in the evaluation of the operating condition of the stator windings of hydro, without either significant loss of sensitivity information or the quantification of the phenomenon.
APA, Harvard, Vancouver, ISO, and other styles
19

PARDAUIL, Ana Carolina Neves. "Uso de técnicas de mineração de dados para a extração de indicação de falha na operação de hidrogeradores a partir de medidas de descargas parciais." Universidade Federal do Pará, 2016. http://repositorio.ufpa.br/jspui/handle/2011/7482.

Full text
Abstract:
Submitted by camilla martins (camillasmmartins@gmail.com) on 2017-01-27T15:40:38Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_TecnicasMineracaoDados.pdf: 5205222 bytes, checksum: 0ac0aceafcb8be8da514e3982160642b (MD5)
Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-01-30T12:17:53Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_TecnicasMineracaoDados.pdf: 5205222 bytes, checksum: 0ac0aceafcb8be8da514e3982160642b (MD5)
Made available in DSpace on 2017-01-30T12:17:53Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_TecnicasMineracaoDados.pdf: 5205222 bytes, checksum: 0ac0aceafcb8be8da514e3982160642b (MD5) Previous issue date: 2016-06-17
Mediante estudos realizados pelo CIGRE em 2009, constatou-se que a fonte principal de falhas elétricas em hidrogeradores estão correlacionados a isolação elétrica. Devido a isto, monitorar as condições do enrolamento estatórico tornou-se primordial e um dos meios de se realizar este procedimento é através da medição e análise de descargas parciais, sendo este um dos métodos mais eficazes e seguros para análise do isolamento do estator do gerador. No entanto, apesar de possuírem padrões bem definidos, não é trivial encaixar os sinais obtidos nestes padrões, devido principalmente ao grande número e variedades de ocorrências de DPs. Este aumento no volume de dados obtidos foi devido a melhorias nos equipamentos e softwares do IMA-DP que viabilizou melhor planejamento e periodicidade nas medições. O uso de uma ferramenta que agilize este processo de identificação e diagnóstico das Descargas Parciais é proposto neste trabalho, baseado em técnicas de mineração dados utilizando árvores de decisão, que é uma solução para análise de grandes volumes de dados. No caso especifico aqui apresentado, utilizou-se 2435 medições provenientes da fase A de um dos hidrogeradores da Casa de Força 1 da Usina Hidrelétrica de Tucuruí, o que foi fundamental para validar o método, pois trata-se de dados reais do sistema. Foi utilizada uma abordagem híbrida (não-supervisionado/ supervisionado) para identificar padrões e posteriormente classifica-los dentre as formas conhecidas de DPs. Obteve-se respostas de classificação dos sinais de forma rápida e muito satisfatória, principalmente ao se converter os dados dos mapas estatísticos em histogramas de amplitude, conseguindo assim, clusters bem definidos e uma árvore de decisão que apresentou índices de acerto global na sua validação acima de 98%.
By studies conducted by CIGRE in 2009, it was found that the main source of hydro generator failures is correlated to the machine electrical insulation. Due to this fact, monitoring the stator winding conditions became an important supervising procedure. A very used practice to accomplish this supervision is through the measurement and analysis of partial discharges (PDs), being this practice one of the most effective and secure methods for analysis of generator stator insulation. However, although PDs have well-defined standards, it is not trivial to classify the obtained PDs signals in these patterns, mainly due to the large number and variety of PDs occurrences. Today, the significant increase in the amount of PDs data available was due to improvements in equipment and software for PDs monitoring, as for example the system IMA-DP, which has contributed to better planned and more frequent measurement campaigns. So, this work proposes the use of an intelligent tool to facilitate the process of identification and diagnosis of partial discharges, based on data mining techniques using decision trees (DT), which is a solution for analyzing large amount of data. In the specific case presented in this dissertation it was used 2,435 measurements obtained for phase A of a hydro generator of the Tucurui Hydro Plant, which was essential to validate the proposed method, because they represent real data obtained from the Hydro Plant operation. A hybrid approach (supervised/unsupervised) was used to identify and rank PDs patterns among the well-known forms of DPs. A fast and very satisfactory PDs classification procedure was achieved, especially when converting data from statistical maps into amplitude histograms, thus, obtaining well-defined clusters and a created decision tree that achieved global indices of accuracy above 98%.
APA, Harvard, Vancouver, ISO, and other styles
20

PEREIRA, Jorge Luiz Moreira. "Estudo dos efeitos das descargas atmosféricas nos índices de desempenho da Subestação de Vila do Conde." Universidade Federal do Pará, 2014. http://repositorio.ufpa.br/jspui/handle/2011/6287.

Full text
Abstract:
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2015-02-05T15:58:26Z No. of bitstreams: 2 license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5) Dissertacao_EstudoEfeitosDescargas.pdf: 3260439 bytes, checksum: fa17a2a9de4c6f3de1135b0c04e86b2e (MD5)
Approved for entry into archive by Ana Rosa Silva (arosa@ufpa.br) on 2015-02-06T13:58:24Z (GMT) No. of bitstreams: 2 license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5) Dissertacao_EstudoEfeitosDescargas.pdf: 3260439 bytes, checksum: fa17a2a9de4c6f3de1135b0c04e86b2e (MD5)
Made available in DSpace on 2015-02-06T13:58:24Z (GMT). No. of bitstreams: 2 license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5) Dissertacao_EstudoEfeitosDescargas.pdf: 3260439 bytes, checksum: fa17a2a9de4c6f3de1135b0c04e86b2e (MD5) Previous issue date: 2014
Este trabalho tem como objetivo apresentar os efeitos de descargas atmosféricas nos índices de desempenho na SE VDC (subestação de Vila do Conde), situada na região norte, no estado do Pará, no período de 2005 a 2013, estabelecendo a relação entre as informações meteorológicas cedidas pelo SIPAM e dados fornecidos pelo centro de operações da Eletronorte de forma a realizar e determinar os efeitos nocivos das descargas atmosféricas, os quais são responsáveis pela intensificação de interrupções no fornecimento de energia elétrica. A análise é restrita à área de atuação da Eletronorte (subestação de Vila do Conde) que tem grande parte de suas Linhas de Transmissão de energia instaladas no Norte do Brasil. O estudo desenvolvido evidência os desligamentos por descargas atmosféricas na linha de transmissão VDC/CASTANHAL de 230 KV e no disjuntor de 500 KV VCDJ7-08.Os resultados demonstram que a incidência de um raio pode causar surtos diretos e indiretos em linhas de transmissão e subestações de alta potência. Neste contexto justifica o estudo de formas eficientes de prevenção, sendo uma das finalidades desta obra, que tem como objetivo geral apresentar informações relativas aos efeitos produzidos pela ação de descargas atmosféricas em subestações do setor elétrico quanto à qualidade de energia, em especial na SE VDC – Sistema Eletrobrás-Eletronorte.
This work aims to present the effects of lightning performance indexes in VDC (substation of Vila do Conde), located in the northern region, in the State of Pará, in the period from 2005 to 2013, establishing the relationship between the weather information provided by the SIPAM and data provided by the center of operations for Eletronorte in order to perform and determine the harmful effects of atmospheric discharges, which are responsible for the intensification of interruptions in the supply of electricity.The analysis is restricted to the area of expertise of Eletronorte (substation of Vila do Conde) which has much of its power transmission Lines installed in northern Brazil. The results show that the incidence of lightning can cause direct and indirect surges in transmission lines and substations of high power. In this context justifies the study of efficient forms of prevention, being one of the purposes of this work, which aims to provide general information concerning the effects produced by the action of atmospheric discharges in substations of the power sector as the quality of energy, in particular in the VDC – Eletrobrás System-Eletronorte.
APA, Harvard, Vancouver, ISO, and other styles
21

SHINKAI, Ricardo de Andrade. "Um simulador para avaliação da influência das características locais das descargas atmosféricas nuvem-solo em sistemas de detecção indireta." Universidade Federal do Pará, 2017. http://repositorio.ufpa.br/jspui/handle/2011/8303.

Full text
Abstract:
Submitted by camilla martins (camillasmmartins@gmail.com) on 2017-04-27T15:02:11Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_SimuladorAvaliacaoInfluencia.pdf: 4428419 bytes, checksum: 9bccb005dec84f96b80a6c9b28ba39b1 (MD5)
Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-05-04T13:12:07Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_SimuladorAvaliacaoInfluencia.pdf: 4428419 bytes, checksum: 9bccb005dec84f96b80a6c9b28ba39b1 (MD5)
Made available in DSpace on 2017-05-04T13:12:07Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_SimuladorAvaliacaoInfluencia.pdf: 4428419 bytes, checksum: 9bccb005dec84f96b80a6c9b28ba39b1 (MD5) Previous issue date: 2017-01-10
O monitoramento do fenômeno das descargas atmosféricas tem sido fundamental para prevenção de incidentes na infraestrutura das empresas que atuam em grandes áreas, como as de energia, telecomunicações e informática. Além disso, fornece dados para o planejamento de sistemas de proteção contra descargas elétricas, evitando assim maiores danos à vida na Terra, e mais recentemente fornecendo informações para sistemas de alertas meteorológicos como os de previsão de tempestades em curto prazo. Portanto, não se trata mais de questão de opção, mas sim de necessidade a instalação e manutenção de sistemas que façam a supervisão destes eventos em escala local, regional e até nacional. Dentre os tipos possíveis, os Sistemas de Detecção Indireta de Descargas Atmosféricas são os que proveem informações mais precisas nas escalas citadas, devido trabalharem com a percepção do impulso eletromagnético gerado pela descarga. Este sinal tem a propriedade de se propagar a médias e longas distâncias em determinadas faixas de frequência, mantendo boa a qualidade da informação do fenômeno que o originou. Porém, a característica fenomenológica dos raios é intrínseca à área monitorada, tornando fundamental o entendimento dessas especificidades para melhor proveito dos sistemas citados. Este trabalho apresenta uma ferramenta computacional para simular a influência das características locais na propagação de ondas eletromagnéticas originadas por descargas atmosféricas nuvem-solo. A metodologia foi utilizada para simular a propagação dessas ondas através do programa MATLAB®, usando como modelo de corrente de retorno no canal de descarga o modelo do tipo de engenharia Linha de Transmissão (TL) para representar o fenômeno elétrico gerado pelo raio.
The monitoring of the phenomenon of atmospheric discharges has been fundamental to prevent incidents in the infrastructure of companies that operate in large areas, such as energy, telecommunications and information technology. In addition, it provides data for the planning of lightning protection systems, thus avoiding further damage to life on Earth, and more recently providing information for weather warning systems such as short-term storm forecasting. Therefore, it is no longer a matter of choice, but rather the need to install and maintain systems that supervise these events on a local, regional and even national scale. Among the possible types, the Lightning Location Systems are the ones that provide more accurate information in the mentioned scales, because they work with the perception of the electromagnetic impulse generated by the lightning. This signal has the property of propagating at medium and long distances in certain frequency bands, maintaining good the information quality of the phenomenon that originated it. However, the phenomenological characteristic of the lightning is intrinsic to the monitored area, making fundamental the understanding of these specificities to better benefit the mentioned systems. This work presents a computational tool to simulate the influence of local characteristics on the propagation of electromagnetic waves caused by cloud-to-ground lightning. The methodology was used to simulate the propagation of these waves through the MATLAB® program, using as model of return current in the discharge channel the model of engineering type the Transmission Line (TL) to represent the electric phenomenon generated by thelightning.
APA, Harvard, Vancouver, ISO, and other styles
22

Braga, Lígia de Oliveira. "Diagnóstico do processo de descarte dos resíduos químicos do Hospital Universitário Oswaldo Cruz em Recife/PE." Pós-Graduação em Desenvolvimento e Meio Ambiente, 2013. https://ri.ufs.br/handle/riufs/4285.

Full text
Abstract:
The waste generation is a current problem and part of human life. The increase of waste grows every day associated with the advancement of technology and industrial production. In this context, are part of the health services, as organizations need to incorporate new concepts to acquire new behaviors in their care processes where issues of environmental preservation and protection of public health need to be highlighted. This challenge has generated public policies and regulations that has assumed great importance as a pillar of sustainable development. These regulations classify healthcare waste generated and have protocols for their management. Within this classification, fall into the chemical waste that is becoming a challenge with regard to the use, disposal and reuse when possible. Thus, this study aims to develop a general diagnosis of the current situation of the management of chemical waste generated at the University Hospital of Pernambuco. Therefore, it was used as the objectives, research is an exploratory-descriptive, as possessing procedure for collecting data literature, field survey, case study and documentary research. The instruments used were the interview guidelines and on-site observation. Given the above and from the survey, we noted the confirmation of the hypotheses on the issues of waste chemicals are not managed according to current legislation, there is no involvement of professionals in planning actions that generate these wastes and that in carrying processes are not taken into account aspects related to the possible chemical waste generated. It can be concluded that although there is a segregation of waste types in the other groups, chemical residues are not treated as such. Needs through the Environmental Education and a new management model train and train practitioners to seek change in the handling of chemical waste. The process of training of professionals and update them need to be continuously and grounded in Environmental Education for the development of new concepts and behavior change that leads to environmental management, considering sustainable development. Why refer to a topic relevant to the issues of environmental and public health, we want to, with the results, cooperate with the academic community showing the problem of chemical waste generated in health services, seeking viable changes to the processes that made generate these wastes, with no loss in quality of care and activities for research.
A geração de resíduos é uma problemática atual e faz parte da vida humana. O aumento de resíduos cresce a cada dia associado ao avanço da tecnologia e da produção industrial. Neste contexto, inserem-se os serviços de saúde que, como organizações, precisam incorporar novos conceitos para adquirir novos comportamentos em seus processos assistenciais onde as questões da preservação do meio ambiente e da proteção da saúde pública precisam ser destacadas. Tal desafio tem gerado políticas públicas e regulamentações que vem assumindo grande importância como eixo para o desenvolvimento sustentável. Estas regulamentações classificam os resíduos de serviços de saúde gerados e dispõem de protocolos para seu manejo. Dentro desta classificação, enquadram-se os resíduos químicos que vem se tornando um desafio no que diz respeito ao uso, descarte e reuso, quando possível. Assim, este trabalho tem como objetivo geral elaborar um diagnóstico da situação atual do gerenciamento dos resíduos químicos gerados em um Hospital Universitário de Pernambuco. Para tanto, foi utilizada, quanto aos objetivos, uma pesquisa do tipo exploratório-descritiva, possuindo como procedimento para coleta de dados a pesquisa bibliográfica, o levantamento de campo, o estudo de caso e a pesquisa documental. Os instrumentos utilizados foram a entrevista em pautas e a observação in loco. Diante do exposto e a partir da pesquisa realizada, evidenciamos a confirmação das hipóteses levantadas em relação às questões dos resíduos químicos não serem gerenciados seguindo a legislação atual, de não existir envolvimento por parte dos profissionais no planejamento das ações geradoras destes resíduos e de que na realização dos processos não são levados em conta os aspectos relacionados aos possíveis resíduos químicos gerados. Pode-se concluir que apesar de existir a segregação dos tipos de resíduos dos outros grupos, os resíduos químicos não são tratados como tais. Precisa-se através da Educação Ambiental e de um novo modelo de gestão capacitar e treinar os profissionais para buscar mudança no manejo dos resíduos químicos. O processo de formação dos profissionais e a atualização dos mesmos precisam ser de modo contínuo e embasado na Educação Ambiental para a concepção de novos conceitos e para a mudança de comportamento que leve à gestão ambiental, considerando o desenvolvimento sustentável. Por se referir a um tema relevante para as questões de saúde pública e ambiental, deseja-se, com os resultados alcançados, colaborar junto à comunidade acadêmica mostrando a problemática dos resíduos químicos gerados nos serviços de saúde, buscando alterações viáveis para os processos realizados que geram estes resíduos, sem que haja perda na qualidade da assistência prestada e das atividades voltadas para pesquisa.
APA, Harvard, Vancouver, ISO, and other styles
23

SANTOS, Luciano Silva dos. "Estudos dos efeitos das descargas atmosféricas nos índices de desempenho da subestação de Vila do Conde e subestação de Marabá." Universidade Federal do Pará, 2016. http://repositorio.ufpa.br/jspui/handle/2011/8300.

Full text
Abstract:
Submitted by camilla martins (camillasmmartins@gmail.com) on 2017-04-27T14:05:39Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_EstudosEfeitosDescargas.pdf: 3450211 bytes, checksum: fca30650fac216b6df30f8e2dc05f5a8 (MD5)
Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-05-04T12:57:18Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_EstudosEfeitosDescargas.pdf: 3450211 bytes, checksum: fca30650fac216b6df30f8e2dc05f5a8 (MD5)
Made available in DSpace on 2017-05-04T12:57:18Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_EstudosEfeitosDescargas.pdf: 3450211 bytes, checksum: fca30650fac216b6df30f8e2dc05f5a8 (MD5) Previous issue date: 2016-05-10
CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico
Este trabalho tem como objetivo apresentar os efeitos de descargas atmosféricas nos índices de desempenho na subestação de Vila do Conde (SE VDC) e de Marabá (SE MB), onde estão situadas na região norte, no estado do Pará, integrando o Sistema Norte - Nordeste de Transmissão da ELETRONORTE, estando interligadas às Usinas Hidrelétrica de Tucuruí (UHE Tucuruí). Foram estudadas, estabelecendo as relações entre as informações meteorológicas cedidas pelo SIPAM e dados fornecidos pelo centro de operações da Eletronorte no período de 2005 a 2013 de forma a determinar os efeitos nocivos das descargas atmosféricas, as quais são responsáveis pela intensificação de interrupções no fornecimento de energia elétrica. A análise por restrita à área de atuação da Eletronorte SE VDC e SE MB. O estudo desenvolvido evidência os desligamentos por descargas atmosféricas na linha de transmissão VDC/CASTANHAL de 230 KV e no disjuntor de 500 KV VCDJ7-08 e linha de transmissão MB/Imperatriz de 500 KV. Os resultados demonstram que a incidência de um raio pode causar surtos diretos e indiretos em linhas de transmissão e subestações de alta potência. Neste contexto justifica o estudo de formas eficientes de prevenção, sendo uma das finalidades deste trabalho.
This paper aims to present the effects of lightning in the performance indices in Vila do Conde substation (SE VDC) and Maraba (SE MB), which are situated in the north, in the state of Pará, integrating the North System - Eletronorte Transmission northeast, being connected to the Tucuruí Hydroelectric Power Plants (HPP Tucuruí). They were studied, establishing relations between the weather information provided by the SIPAM and data provided by central Eletronorte's operations in the period 2005-2013 in order to determine the harmful effects of lightning, which are responsible for the intensification of supply interruptions electricity. The analysis restricted to the area of operation of Eletronorte SE and SE VDC MB. The study developed evidence disconnections by lightning on transmission line VDC / CASTANHAL 230 KV and 500 KV breaker VCDJ7-08 and transmission line MB / Empress of 500 KV. The results demonstrate that a lightning strike may cause direct and indirect surges in transmission lines and high power substations. In this context it justifies the study of efficient forms of prevention, one of the purposes of this work.
APA, Harvard, Vancouver, ISO, and other styles
24

Baptista, Margarete ártico. "Eventos adversos e motivos de descarte relacionados ao reuso dos produtos médico-hospitalares em pacientes submetidos a angioplastia coronária." Faculdade de Medicina de São José do Rio Preto, 2006. http://bdtd.famerp.br/handle/tede/214.

Full text
Abstract:
Made available in DSpace on 2016-01-26T12:51:50Z (GMT). No. of bitstreams: 1 margareteartico_dissert.pdf: 621420 bytes, checksum: d6484338aa944f835c788d5909f93257 (MD5) Previous issue date: 2006-05-17
The reuse of health care products [medical and supply hospital products] is a practice carried out by several countries. The hemodynamic catheters, which are used for diagnosis examination and cardiac procedures, such as coronary angioplasty, are the most reutilized ones. The technical difficulties to reprocess the products and the adverse events are important issues for those who decide for the reutilization of these products. Objectives: To describe the adverse events presented by the patients during and after the coronary angioplasty possibly related to the reuse of health care products [medical and supply hospital products], and to quantify and identify the reasons to discard the products in relation to both the first use and to the reuse. Casuistic and Method: Of 60 patients who were submitted to coronary angioplasty, 33 (55%) were men. The age ranged from 42 to 88 years-old, 63 ± 10 years [mean ± SD]. According to the anamnesis, 22 patients (36.7%) presented hypertension, and 10 (16.7%) had diabetes. Of this group, 15 patients (25%) were smokers, and 8 (13.3%) were alcoholics. Of the 60 patients, 29 (48.3%) presented unstable angina, 27 (45%) had AMI (acute myocadial infarction), and 4 (6.6%) other diagnoses. During the procedure and the permanence in the Intensive Care Unit (ICU) the occurrences of adverse events, such as fever, hypertension, hypotension, chills, sudoresis, bleeding, nausea, and vomit presented by the patients have been observed. Seven medical devices have been evaluated: introductor, guiding catheter, guidewire 0.35, guidewire 0.014, balloon catheter for angioplasty, a syringe with manometer to insufflate the balloon (indeflator), and a three-way (3) stopcock (manifold). Of these, 76 were first-use products and 410 reprocessed products. It was verified if the same products were discarded before or during the procedure, and which were the reasons that led these products to be discarded. The categorical variables have been analyzed with the chi-square test (χ2 test). The discrete quantitative variables have been analyzed with a nonparametric statistical test for ordinal data (Mann-Whitney test). A type I error of 5% was admitted. Results: The results have highlighted that 26 patients presented adverse events. Hypotension was the most clinically significant adverse event and occurred in 11 (18.3%) of the patients. There was not, however, a statistical significance between the hypotension adverse event and the reuse of the products. Four first-use products and 80 reused products have been discarded. Three first-use products and 55 reused products have been discarded because they were damaged. We want to emphasize that all the syringes used to insufflate the balloon, which have been discarded, have been so for this reason. Conclusions: The adverse events presented by the patients submitted to angioplasty are not related to the reuse of the health care products. The medical devices integrity and functionality have been the main reason of the discards.
O reuso dos produtos médico-hospitalares é uma prática realizada por vários países. Os cateteres de hemodinâmica que são empregados para os exames de diagnósticos e intervenções cardíacas como a angioplastia coronária, são os mais reutilizados. As dificuldades técnicas para o reprocessamento dos produtos e os eventos adversos são questões importantes para quem decide pela reutilização desses produtos. Objetivos: Descrever os eventos adversos apresentados pelos pacientes durante e após a angioplastia coronária, possivelmente relacionadas ao reuso dos produtos médico-hospitalares além de quantificar e identificar os motivos de descarte dos produtos em relação ao primeiro uso e ao reuso. Casuística e Método: Foram estudados 60 pacientes submetidos a angioplastia coronária. Deste grupo 33 (55%) eram homens. A idade variou de 42 a 88 anos, com média e desvio padrão de 63 ± 10 anos. De acordo a anamnese 22 (36,7%) apresentavam hipertensão arterial e 10 (16,7%) tinham diabetes. Deste grupo 15 (25%) eram fumantes e 8 (13,3%) eram etilistas. Dos 60 pacientes, 29 (48,3%) apresentavam angina instável, 27 (45%) IAM e 4 (6,6%) outros diagnósticos. Durante o procedimento e na permanência na Unidade Intensiva Coronariana (UCOR), foram observadas as ocorrências dos eventos adversos, febre, hipertensão, hipotensão, calafrios, sudorese, sangramento, náuseas e vômitos, apresentados pelos pacientes. Foram avaliados, sete produtos médico-hospitalares, introdutor, cateter guia, fio guia 0.35, fio guia 0.014, cateter balão para angioplastia, seringa com manômetro para insuflar balão (indeflator) e torneirinha de 3 vias descartável (manifold), sendo 76 de primeiro uso e 410 reprocessados. Verificou-se se os mesmos foram descartados antes ou durante o procedimento e quais os motivos que levaram a esses descartes. As variáveis categóricas foram analisadas com o auxilio do teste Qui Quadrado. As variáveis quantitativas discretas foram analisadas com o auxilio de teste não paramétrico (Mann-Whitney). Foi admitido erro alfa de 5%. Resultados: Os resultados evidenciaram que 26 (43,3%) dos pacientes apresentaram eventos adversos. A hipotensão foi o evento adverso mais relevante clinicamente e ocorreu em 11(18,3%) dos pacientes. Não houve, porém, significância estatística entre o evento adverso hipotensão e o reuso dos produtos médico-hospitalares. Foram descartados 4 produtos de primeiro uso e 80 dos reutilizados. Por não estarem íntegros, foram descartados 3 produtos de primeiro uso e 55 produtos dos reutilizados. Destaca-se que todas as seringas de insuflar balão, que foram descartadas, o foram por esse motivo. Conclusões: Os eventos adversos apresentados pelos pacientes submetidos à angioplastia não estão associados ao reuso dos produtos médico-hospitalares. A integridade e funcionalidade foram os motivos principais de descartes dos produtos médico-hospitalares.
APA, Harvard, Vancouver, ISO, and other styles
25

Santos, Jânia Oliveira. "Descarte de resíduos resultantes da atividade de vacinação da rede municipal de Palmas – TO: uma abordagem com foco na saúde do trabalhador e na preservação do meio ambiente." Universidade Federal do Tocantins, 2017. http://hdl.handle.net/11612/481.

Full text
Abstract:
Trata-se de estudo descritivo, realizado nas 31 Unidades de Saúde (US) do Sistema Único de Saúde, que administram vacinas no município de Palmas / Tocantins - Brasil, com objetivo de comparar as práticas profissionais de descarte de resíduos de vacinação com a normatização técnica federal que faz referência ao gerenciamento de resíduos de saúde, com destaque para a RCD n° 306/2004 da ANVISA, a Resolução n° 358/2005 do Conselho Nacional do Meio Ambiente (CONAMA) e para as normativas da Associação Brasileira de Normas Técnicas (ABNT). Buscou-se também identificar ações realizadas nas US que minimizam a geração dos resíduos de vacinação e que expõem o meio ambiente e os trabalhadores a riscos de contaminação. Os dados foram coletados no período de junho a novembro de 2016 por meio de observação direta com utilização de roteiro composto por diferentes fases do gerenciamento dos resíduos, em seguida foram analisados por meio de estatística descritiva. Ao comparar as práticas realizadas com as recomendações da legislação e normativas da ABNT referentes a resíduos de serviço de saúde, observou-se que em todas as unidades de saúde ocorreram falhas em relação ao gerenciamento dos resíduos de vacinação, sendo que as intraestabelecimento foram predominantes. Tal realidade pode expor trabalhadores, usuários e meio ambiente ao risco de contaminação. É necessário rever as práticas de gerenciamento dos resíduos de vacinação que são realizadas nas unidades públicas de saúde de Palmas-TO, assim como treinar/capacitar os profissionais das salas de vacinação em relação ao tema.
This is a descriptive study carried out in the 31 Health Units (HU) of Unified Health System (SUS) that administer vaccines in Palmas, Tocantins - Brazil, in order to compare the professional practices of vaccination waste disposal with the federal technical regulation that refers to the health waste management, with emphasis on RCD 306/2004 of ANVISA and resolution 358/2005 of the National Environment Council, in addition to the Brazilian Association of Technical Standards (ABNT) regulations. It was also sought to identify actions taken in the HU that minimize the generation of vaccination residues and that expose the environment and workers to contamination risks. The data were collected from June to November of 2016 through direct observation using a road map composed of different phases of waste management, and then analyzed using descriptive statistics. When comparing the practices carried out with the legislation recommendations and ABNT regulations regarding health service residues, it was observed that in all health units there were flaws related to the management of vaccination residues, and intraestablishment were predominant. Such a reality can expose workers, users and the environment to contamination risk. It is necessary to review the vaccination waste management practices that are carried out in public health units in Palmas-TO, as well as to train vaccination room professionals on the subject.
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography