Dissertations / Theses on the topic 'Medidor ultrassônico de vazão'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the top 26 dissertations / theses for your research on the topic 'Medidor ultrassônico de vazão.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.
CAMPOS, Mateus Mendes. "Medidor de Vazão Ultrassônico de Multi-Trajetórias." reponame:Repositório Institucional da UNIFEI, 2017. http://repositorio.unifei.edu.br/xmlui/handle/123456789/841.
Full textMade available in DSpace on 2017-07-12T17:25:25Z (GMT). No. of bitstreams: 1 dissertacao_campos2_2017.pdf: 9639554 bytes, checksum: b3f737dc2ceacc8c975118f70c0e4cbc (MD5) Previous issue date: 2017-06
Embora existam diversas abordagens para medições de vazão, o método ultrassônico de multi-trajetórias tem ganhado interesse pela indústria e por pesquisadores, pois tais medidores apresentam robustez, boa exatidão e precisão, e podem atingir classes de exatidão menores que 1%. Esta abordagem também permite a medição de grandes vazões, medições bidirecionais de fluxo e flexibilidade quanto ao fluido a ser medido. O presente trabalho apresenta o desenvolvimento de um medidor de vazão ultrassônico de multi-trajetórias utilizando o método de tempo de trânsito, com base nas informações contidas na norma IEC41. O protótipo desenvolvido consiste na eletrônica de emissão e recepção das ondas ultrassônicas, processamento de sinais e no software de cálculo de vazão. O projeto visa o uso de dezesseis transdutores, formando oito trajetórias acústicas divididas em dois planos cruzados, porém, arranjos com outras estruturas são previstos no sistema. A técnica de Correlação Cruzada foi utilizada para medir os tempos de trânsitos entre os sinais ultrassônicos. Resultados de simulação são apresentados no documento, assim como medições feitas em laboratórios de calibração de medidores de vazão comparando os valores medidos pelo protótipo com o valor obtido no laboratório.
STANGE, R. "ESTIMATIVA do Fator de Perfil k na Medição Ultrassônica Por Tempo de Trânsito em Escoamentos Assimétricos Utilizando a Técnica de Problemas Inversos Acoplada a Simulação Numérica." Universidade Federal do Espírito Santo, 2017. http://repositorio.ufes.br/handle/10/9756.
Full textA medic¸ao de vazao ´e uma importante opera¸cao no escopo das aplica¸coes industriais, sendo regulamentado por diversos ´orgaos reguladores. Para satisfazer tais exigencias, a tecnologia por medi¸cao ultrassonica tem passado por grande evolu¸cao nos u´ltimos anos, muito em func¸ao de sua caracter´ıstica de baixa perda de carga associada, devido `a sua configura¸cao. Contudo, acidentes de linha causam interferencia em suas leituras, devido a altera¸coes no perfil de velocidades do escoamento. Novas pesquisas e modelos sao apresentados de forma a entender e considerar tais perturba¸coes, e adaptar as condi¸coes das instala¸coes industriais. De modo a agregar novos esfor¸cos, o presente trabalho apresenta uma aproxima¸cao do fator de perfil k atrav´es de t´ecnicas de problemas inversos. Essa abordagem busca quantificar as altera¸coes no perfil de velocidade e considerar tais efeitos no fator k. Neste trabalho foram abordadas simulac¸oes de escoamentos com Nu´mero de Reynolds entre 1⇥104 a2⇥106 sob influencia de curvas. Aproxima¸coes foram feitas com simula¸coes a 10D, 20D e 80D a` jusante da curva. Os resultados encontrados mostram-se promissores, sendo que, as diferen¸cas entre as simulac¸oes obtidas atrav´es da presente proposta para o fator k e os valores de vazao de referencia, ficaram abaixo de 2% na maioria dos casos simulados. Palavras-chave: Medidor de vazao ultrassonico, canal acu´stico, escoamentos turbulentos, problema inverso, Levemberg-Marquardt.
LIMA, E. S. M. "Análise Experimental da Sensibilidade da Tecnologia Ultrassônica para Medição de Gás de Queima Sob o Efeito de Curva." Universidade Federal do Espírito Santo, 2013. http://repositorio.ufes.br/handle/10/4201.
Full textA indústria de petróleo e gás requer medições de vazão com baixa incerteza, uma vez que são estabelecidas por lei. Contudo, curvas e outros obstáculos são comumente encontrados nesse cenário, o que pode afetar a qualidade da medição de vazão em função de perturbações no escoamento, tais como swirl e assimetrias no perfil de velocidades. Em sistemas de gás de tocha, que são comumente utilizados como sistemas de segurança e alivio em ativos produtores de hidrocarbonetos, a sua quantificação tem sido considerada por especialistas como uma condição de medição das mais desafiadoras, tendo em vista que esses escoamentos apresentam tipicamente características tais como, instalações em grandesdiâmetros, necessidade de baixos índices de manutenção, necessidade de baixa intrusividade ao processo, variações na composição química do gás, presença eventual de líquidos (condensado ou gotículas de óleo), que contribuem para que a adequação dessa medição aos requisitos da legislação seja um problema tecnológico de elevada relevância. Medidores de vazão por ultrassom de um canal acústico são frequentemente utilizados em instalações de queima de gás de tocha, apesar de serem sensíveis a tais perturbações promovidas pela presença de acidentes de instalação. À vista disso, este trabalho visa à análise experimental do efeito de curvas na medição de Gás de tocha. Sob esse aspecto, o objetivo deste trabalho é analisar experimentalmente o comportamento das leituras de um medidor ultrassônico (UFM) sob efeito de curvas em um túnel de vento atmosférico com medição de referência por tubo de Pitot. Os resultados obtidos demonstram que as leituras do UFM sofrem influência dos efeitos de curvas quando o trecho de medição é variado. Palavras chave: Medidor ultrassônico de vazão, Pitot, gás de queima
ABOUJAOUDE, F. "Avaliação Experimental do Desempenho de Protótipo de Medidor de Vazão para Óleos Pesados Por Tecnologia Ultrassônica Por Tempo de Trânsito." Universidade Federal do Espírito Santo, 2017. http://repositorio.ufes.br/handle/10/6920.
Full textA medição ultrassônica por tempo de trânsito vem sendo utilizado cada vez mais nos últimos anos, havendo, sem dúvida, a necessidade urgente de desenvolvimento de tecnologia brasileira neste campo da instrumentação. Este trabalho se dedica ao estudo de medição de vazão em óleos pesados por ultrassom com a pretensão de verificar experimentalmente a validade dos processos estatísticos utilizados visando a redução das incertezas nas leituras. Para isso o trabalho analisa experimentalmente efeitos de possíveis erros do medidor por tempo de trânsito validando-os em relação a um medidor de vazão de referência. Medidor Ultrassônico, tempo de trânsito, óleo pesado, medição de vazão
Strieder, Andre. "Medidor de vazão por transferencia termica." [s.n.], 2004. http://repositorio.unicamp.br/jspui/handle/REPOSIP/263787.
Full textDissertação (mestrado profissional) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica
Made available in DSpace on 2018-08-04T02:08:56Z (GMT). No. of bitstreams: 1 Strieder_Andre_M.pdf: 5509615 bytes, checksum: 50eeec27792444c72caf472ea5132345 (MD5) Previous issue date: 2004
Resumo: Neste trabalho procurou desenvolver-se um medidor de vazão que permitisse medir a vazão de ar em um duto fechado através do principio de transferência térmica. Para isto é necessário desenvolver um sensor termo-resistivo e estudar seu comportamento quando submetido a diferentes vazões e temperaturas. É necessário também projetar um circuito eletrônico microcontrolado para medir o sinal de tensão gerado pelo circuito do sensor, a temperatura do fluido e realizar cálculos para determinar a vazão. Utilizou-se método onde o sensor termo-resistivo opera em temperatura constante através de circuito de medição com amplificador operacional realimentado pela saída. A equação que rege o comportamento do sensor termo-resistivo em equilíbrio termodinâmico estático, quando é atravessado por uma corrente elétrica e está em um meio onde sofre a ação da velocidade de um fluido é utilizada para o cálculo da vazão.O cálculo é realizado pelo microcontrolador através de coeficientes, obtidos experimentalmente, que relacionam a velocidade do fluido com o coeficiente de transferência térmica do sensor.Os resultados obtidos com dois tipos de sensor diferentes foram analisados e comparados e o resultado final do cálculo de vazão foi comparado com um medidor de referência obtendo uma boa concordância. Os resultados deste trabalho demonstram a capacidade do sistema para medição de vazão de gases que pode ser estendida também para outros fluidos
Abstract: We described the development of a flow meter instrument that provides to measure the air flow in a closed tube employing the Thermal Transfer Principle. To achieve this purpose we developed a thermoresistive sensor and we studied your behaviour in different flows and temperatures. It was necessary to project an electronic microcontroled circuit to measure the voltage signal generated by the sensor circuit, the fluid temperature and to determine the flow through calculations. We employed the method that uses a constant temperature in the thermoresistive sensor by the measure with an operational amplifier which is a feedback control circuit. The equation that determines the thermoresistive behaviour in static thermodynamic equilibrium submitted to electric current and to fluid velocity is employed in the flow calculation. The calculation is realized by the microcontroler through experimental coefficients that determine the relation between the fluid velocity with the thermal transfer coefficient of the sensor. The results obtained with two different sensors were analyzed and compared. The final calculated experimental result was compared with the results of a standard meter, showing a good correlation. We demonstrated the capability of the flow measure of gases, but the system could be extrapoled for another fluids as liquids
Mestrado
Instrumentação e Controle Industrial
Mestre Profissional em Engenharia Mecanica
Oliveira, Marcos Antônio Andrade de. "Desenvolvimento de um Medidor de Vazão Termal Inteligente." Universidade do Estado do Rio de Janeiro, 2010. http://www.bdtd.uerj.br/tde_busca/arquivo.php?codArquivo=7447.
Full textNon-intrusive techniques of flow measurement are very useful in several applications. Nowadays, several studies have been conducted to develop non-intrusive measuring techniques that can overcome the shortcomings of the existing ones. This work aims to design an intelligent non-intrusive flow meter device based on the forced heat convection principle (thermal). This device uses two commercial RTD transducers (PT100), one is used as reference of temperature set-point, and the other is responsible for the flow measurement. A neural network is responsible for correcting the errors in relation to the calibration standard. To evaluate the intelligent flow meter, test bench was built. In order to provide another flow meter to compare the results, an ABNT Venturi type flow meter was installed in the test bench.
Varon, Mauricio Pardo 1984. "Estudo de uma bomba centrífuga submersa (BCS) como medidor de vazão." [s.n.], 2013. http://repositorio.unicamp.br/jspui/handle/REPOSIP/265668.
Full textDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica e Instituto de Geociências
Made available in DSpace on 2018-08-22T09:14:58Z (GMT). No. of bitstreams: 1 Varon_MauricioPardo_M.pdf: 5247609 bytes, checksum: ddfee289e17057b479b10f2913e86805 (MD5) Previous issue date: 2013
Resumo: O Bombeio Centrífugo Submerso (BCS) é um dos métodos mais importantes de elevação artificial de petróleo, no Brasil e no mundo. A bomba de BCS é acionada por um motor elétrico acoplado diretamente ao eixo da bomba. Comumente, possui também um conjunto de sensores que fazem o monitoramento da operação do motor, além de outras variáveis próprias como, por exemplo, o ganho de pressão gerado pela BCS. Por outro lado, a operação remota do motor na superfície se dá através de um inversor de frequência que fornece, além da rotação, o consumo elétrico da BCS. A medição da vazão de líquido produzida por cada poço é tradicionalmente realizada com instrumentação especializada de alto custo. Dado que o sensor do motor da BCS e o inversor de frequência que a opera já fornecem informações utilizadas para o monitoramento do equipamento e para o gerenciamento do poço, a vazão de líquido local na BCS poderia ser determinada com base em curvas de desempenho previamente levantadas nas condições de operação esperadas. O ganho de pressão gerado pela BCS e a potência elétrica consumida pelo motor que a aciona são as variáveis de desempenho consideradas neste estudo para avaliar a incerteza da vazão de líquido local estimada através da bomba em diversas condições de operação (incluindo escoamento bifásico e viscoso). A avaliação é feita com base na norma API RP 11S2, que estabelece as práticas recomendadas para testes de BCS
Abstract: ESP (Electrical Submersible Pump) is one the most important artificial lift methods for oil in Brazil and worldwide. The centrifugal pump is driven by an electric motor directly coupled to the pump shaft. Commonly, also has a set of sensors that monitor the electric motor operation, and other variables themselves, for example, the pressure gain generated by the ESP. Moreover, the remote operation of the equipment at the surface is performed via a frequency inverter that provides, in addition to the rotation, the power consumption of the ESP. Measurement of liquid flow rate produced by each well is traditionally performed with specialized instrumentation costly. As the motor sensor and the frequency inverter that drives the ESP already provide information used for monitoring equipment and for managing the well, the local liquid flow rate in the ESP could be determined based on correlations with these data. The pressure gain generated by the ESP and electrical power consumed by the motor are the considered variables for this study to correlate with the flow rate of fluid produced and to assess the quality of the results by analyzing uncertainties. To achieve this, a series of performance curves are obtained at different operating conditions (including two-phase flow and viscous) to observe how the uncertainty of the results are affected by correlated variables. The assessment is based on the standard API RP 11S2, which establishes best practices for testing BCS
Mestrado
Explotação
Mestre em Ciências e Engenharia de Petróleo
Camargo, Antonio Pires de. "Desenvolvimento de um medidor eletrônico de vazão utilizando célula de carga." Universidade de São Paulo, 2010. http://www.teses.usp.br/teses/disponiveis/11/11143/tde-19022010-080513/.
Full textNew available equipments and technologies in the market are each time more important for the agricultural section development and modernization. The electronics and automation area have great value on this evolution, speeding up activities as well as decreasing costs, mainly those costs regarding with necessary labor to execute routine tasks. On irrigation there is a common objective of choosing techniques that optimize crops water use, increasing efficiency and reducing losses of water distribution and application processes. The flow metering in an irrigation system is indispensable stuff when an efficient water management is desired. There are many tools, devices and methods of flow metering each one with its respective features. Considering a technology innovation principle this work had the purpose to develop an electronic flow meter easy to use and low cost, using electronic devices. Nevertheless this research had the following objectives: a) An electronic flow meter development by using load cell; b) Hydraulics tests in order to determine a math equation that matches the instantly flow inside a pipeline; and c) Flow meter assess determining performance parameters. The research was done at Hydraulics Laboratory, Rural Engineering Department (Laboratório de Hidráulica - Departamento de Engenharia Rural), ESALQ/USP on Piracicaba-SP-Brazil. The developed equipment is based on drag force that a body experiences when immersed in a fluid stream. The flow meter developed has some screen options allowing user tasks definition like: metering, calibration, and make some internal configurations. In the metering task the flow value is updated on intervals close to 7 seconds being possible to select or change units showing flow results. The calibration task was developed to avoid or release the specialized labor need, equipments, computers or any sophisticated and complex method. In this task, it was implemented Least Square Method in order to calculate coefficients of a fitting equation. This equation was used to estimate flow from digital signals acquired from the electronic circuit. The configuration interface allows the visualization and change the fitting equation used by the system. It also allows the data transmission for computers by serial port (RS-232 protocol). The proposed flow meter is able to work from 7 to 28 m³.h-1 with uncertainty of ±1.4 m³.h-1 (± 2.7%). The coefficient of local head loss (K) was close to 0.55 for Reynolds number values higher than 105. In this work, the greatest drag force expected acting on the flat circular body and cylindrical object is about 1.87 N, resulting in a force on load cell up to 3 N.
Barañano, Audrei Giménez. "Utilização de observador de estado em substituição a medidor de vazão." Florianópolis, SC, 2006. http://repositorio.ufsc.br/xmlui/handle/123456789/89548.
Full textMade available in DSpace on 2012-10-22T22:56:47Z (GMT). No. of bitstreams: 1 229614.pdf: 1314542 bytes, checksum: 0d7589fe60f5e588a50b5920d9480def (MD5)
O objetivo deste trabalho é estimar, indiretamente, a vazão de escoamento em tubulações, tanto em estado estacionário quanto em transientes, que são comuns em processos de fluxo de fluidos em tubulações. A idéia é utilizar medidas de pressão nos extremos do duto, que sempre são disponíveis e mais confiáveis que as medidas de vazão, e utilizar informação das válvulas localizadas nos extremos como medidores de vazão baseados em pressão diferencial de orifício variável. Isso pode ser feito a partir da informação de abertura das válvulas. Desta forma, é possível quantificar a vazão com o conhecimento prévio da abertura da válvula e a pressão lida à sua jusante ou montante, através do uso da equação do orifício. Foi utilizada uma formulação não-linear e uma linearizada para o escoamento dinâmico de um fluido compressível, em espaço de estados. O modelo não-linear para este tipo de problema é composto de um conjunto de equações diferenciais parciais hiperbólicas, e a forma de resolução adotada é a discretização por diferenças finitas centrais. Os contornos do problema abordado são duas válvulas de controle nos extremos da tubulação. As equações que descrevem o movimento dessas válvulas são linearizadas e acopladas ao modelo dinâmico, de forma que elas são utilizadas como medidores de orifício variável para fins de medição de vazão. O modelo não-linear é resolvido nas condições de escoamento experimentais para sua validação. Esse modelo também é linearizado e acoplado a uma matriz de ganho (formando o observador de estado) e assim corrige as diferenças entre a simulação do modelo linearizado e as medições experimentais.
BARROS, W. F. "ANÁLISE da Variabilidade Induzida pela Concentração de Co2 nas Leituras de Medidores de Vazão Ultrassônicos para Gás de Queima." Universidade Federal do Espírito Santo, 2016. http://repositorio.ufes.br/handle/10/9816.
Full textO efeito produzido pelo caráter atenuante do dióxido de carbono sobre o desempenho de um medidor de vazão ultrassônico em aplicações de gás de queima foi verificado. Para isso, experimentos foram realizados em túnel de vento com número de Reynolds em 104. Resultados indicam que o medidor ultrassônico apresentou falhas de medição em estágios de variação acentuada deste gás e cujos teores se mostraram acima de 5%, sendo verificado também que uma aproximação dos transdutores tende a reduzir estes erros de medição. Palavras-chave: Gás de queima. Medição de vazão. Medidor ultrassônico. Atenuação. Dióxido de carbono.
Siqueira, Natally Annunciato. "Medidor de vazão de água, tipo \"Pitot-Cole\", com configuração prismática hexagonal." Universidade de São Paulo, 2018. http://www.teses.usp.br/teses/disponiveis/3/3147/tde-20092018-092013/.
Full textFlow measurements are essential for processes management that include fluids. In water companies, measuring inlets and outlets of water is essential to manage revenue and water losses. The water flow can be measured through different instruments with different application principles. The Pitot Cole Tube is able to determine flow in pipes through the pressure differential. This device was invented in 1732 by Henri Pitot to determine fluid velocity and it was improved by Eduard Cole in 1896, allowing to apply the instrument in pipes. The main advantages are the low cost and easy installation, that may occur with the pipe under load. However, the fragility and complexity of its pieces motivated this study: the construction of a simple and robust instrument to measure the water flow. It is proposed the construction of a prototype with pressure plugs installed on opposite faces of a hexagonal prism, then evaluation of its effectiveness in water flow measurements. The results were promising given the stability obtained in the calibration coefficient.
Guimarães, Adriana Biassus. "MEDIDOR DE VAZÃO PROPORCIONAL PARA A QUANTIFICAÇÃO DO CONSUMO DE ÁGUA NA IRRIGAÇÃO." Universidade Federal de Santa Maria, 2007. http://repositorio.ufsm.br/handle/1/7488.
Full textThe present work had for objective to develop a simple process, with low cost and enough precise for its use in irrigation systems. The measurer consists of a secondary canalization provided with a hydrometer of low outflow installed in parallel with a singularity capable to provoke a pressure difference enters the extreme points of the device. The distinguishing pressure induces to the partial draining of the water through the secondary canalization being measured for the hydrometer. The work was developed in the Irrigation, Hydraulical and Draining laboratory of the Department of Agricultural Engineering of the Federal University of Santa Maria and in a system of water main for a central pivot installed in the Mayã Farm, in the city of São Sepé - RS. The work consists in the evaluation of a proportional measurer of volume (or outflow) and of the posterior application for the estimate of the volume of water fed for the system of bombardment to an expository of a system of irrigation of the type central pivot. The proportional measurer presents easiness about the construction and installation in the field. The results allowed concluding that the proportional measurer was capable to estimate the outflow of the central pivot irrigation system. The proportional measurer can be installed and operated in a simple way, and its components are of easy acquisition and low cost and maintenance. Such characteristics assume great importance in the current days becoming viable the implantation of systems of measurement in all the existing systems of irrigation in the agricultural way.
O presente trabalho teve por objetivo desenvolver um processo simples, de baixo custo e suficientemente preciso para a sua utilização em sistemas de irrigação. O medidor consiste de uma canalização secundária provida de um hidrômetro de baixa vazão instalada em paralelo com uma singularidade capaz de provocar uma diferença de pressão entre os pontos extremos do dispositivo. A pressão diferencial induz ao escoamento parcial da água através da canalização secundária sendo medida pelo hidrômetro. O trabalho foi desenvolvido no laboratório de Hidráulica, Irrigação e Drenagem do Departamento de Engenharia Rural da Universidade Federal de Santa Maria e em um sistema de bombeamento para adução de água para um pivô central na instalado na Fazenda Mayã, município de São Sepé RS. O trabalho consta da avaliação de um medidor de volume (ou de vazão) proporcional e da posterior aplicação para a estimativa do volume de água alimentado pelo sistema de bombeamento a uma adutora de um sistema de irrigação do tipo pivô central. O medidor proporcional apresenta facilidade quanto à sua construção e instalação no campo. Os resultados obtidos permitiram concluir que o medidor proporcional foi capaz de estimar com precisão a vazão da adutora de alimentação de um sistema de irrigação do tipo pivô central. O medidor proporcional pode ser instalado e operado de modo simples, sendo que seus componentes são de fácil aquisição e de baixo custo e manutenção. Tais características assumem grande importância nos dias atuais contribuindo para a implantação de sistemas de medição em todos os sistemas de irrigação existentes no meio rural.
Ramos, Rodrigo. "Desenvolvimento de medidor de vazão de gás por ultra-som : modelagem, protótipo e testes." Universidade Federal do Espírito Santo, 2006. http://repositorio.ufes.br/handle/10/6251.
Full textThe use of transit time ultrasonic flow measurement technique has increased very quickly in the last years, so that it is urgently necessary to develop Brazilian technology in this instrumentation field. This work presents the development of a transit time flow meter prototype, called MEVUS, devoted to measurement of gas flows. It presents the mathematical modeling of the governing physical process of the interaction between the ultrasonic wave and the flow that one wants to measure, which is supposed completely developed in a circular pipe. It also presents a systematization of the uncertainty analysis related to the measurement process. The process of conception, analysis and design of the prototype is equally described, so that the reader can easily understand the problems found during the development, highlighting the proposed solutions and the feedback of the creation process of MEVUS Medidor de Vazão por Ultra-Som (Ultrasonic Flowmeter). Performance tests were conducted in the Flow Machines Laboratory of the Mechanical Engineering Department UFES. They are clearly described. The conclusions are presented, as well as the suggestions for future works
A medição ultra-sônica por tempo de trânsito vem alargando velozmente seu campo de aplicação nos últimos anos, havendo, sem dúvida, a necessidade urgente de desenvolvimento de tecnologia brasileira neste campo da instrumentação. O trabalho apresenta o desenvolvimento de um protótipo, batizado de MEVUS, para medidor de vazão ultra-sônico por tempo de trânsito voltado à medição de vazão de gás. Desenvolve-se a modelagem matemática do processo físico que governa a interação entre a onda ultra-sônica e o escoamento que se deseja medir, o qual se supõe plenamente desenvolvido numa tubulação circular. Apresenta-se também a sistematização da análise de incertezas. O processo de concepção, análise e projeto do protótipo é igualmente descrito, permitindo ao leitor a compreensão dos desafios enfrentados durante as atividades, destacando as soluções propostas e realimentação do processo de desenvolvimento do MEVUS Medidor de Vazão por Ultra-Som. Os testes preliminares de desempenho conduzidos no Laboratório de Máquinas de Fluxo do departamento de Engenharia Mecânica UFES são claramente descritos, apresentando-se as conclusões e as sugestões de trabalhos futuros
Martim, André Luís Sotero Salustiano 1976. "Avaliação do desempenho de um medidor de vazão eletromagnetico em situações praticas reais de instalação." [s.n.], 2005. http://repositorio.unicamp.br/jspui/handle/REPOSIP/257855.
Full textDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo
Made available in DSpace on 2018-08-06T04:58:32Z (GMT). No. of bitstreams: 1 Martim_AndreLuisSoteroSalustiano_M.pdf: 5209979 bytes, checksum: cd531521e2ae52a28d5dcfc9952e9dd2 (MD5) Previous issue date: 2005
Resumo: Martim, André Luís Sotero Salustiano. Avaliação do Desempenho de um Medidor de Vazão Eletromagnético em Situações Práticas Reais de Instalação. Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo, Universidade Estadual de Campinas, 2005. 182 páginas. Dissertação. A busca do melhor aproveitamento dos recursos hídricos é uma característica permanente nas políticas atuais, e o gerenciamento de recursos hídricos implica no equacionamento entre a vazão disponível e a vazão de demanda, ou seja, na medição de vazão. A partir de 2004 os usuários de recursos hídricos são obrigados a declarar os volumes de água captados, é a declaração anual de uso de recursos hídricos. A qualidade da vazão medida depende das técnicas de medição, e um dos principais fatores intervenientes é a condição de instalação do medidor. A avaliação de um medidor eletromagnético de vazão em condições práticas de instalação foi desenvolvida experimentalmente neste trabalho. O medidor de vazão eletromagnético utilizado foi instalado em quatro situações diferentes e os valores de vazão obtidos foram comparados com os de dois medidores instalados adequadamente, um medidor Venturi e um medidor Ultra-sônico. Os ensaios foram desenvolvidos em uma bancada no Laboratório de Hidráulica e Mecânica dos Fluidos da Faculdade de Engenharia Civil da Unicamp. Para a configuração com o medidor eletromagnético instalado à jusante de uma curva 900 de raio curto, o desvio máximo foi de 0,742% com uma incerteza de 0,27%. Para a configuração com o medidor eletromagnético instalado à jusante de duas curvas 900 de raio curto, o desvio máximo foi de 0,447% com uma incerteza de 0,74%. Para a configuração com o medidor eletromagnético instalado à jusante de uma válvula de gaveta, com 50% de abertura, o desvio máximo foi de -2,046% e uma incerteza de 0,50%. Os resultados obtidos mostram claramente que a condição de instalação do medidor frente às singularidades da tubulação afetam sua performance. Os valores de desvio de indicação podem ser considerados baixos ou altos, dependendo da exatidão exigida do medidor dentro do sistema
Abstract: Martim, André Luís Sotero Salustiano. Evaluation of the performance of an electromagnetic flowmeter in real practical situations of installation. Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo, Universidade Estadual de Campinas, 2005. The search of the best utilization of the water resources is a permanent characteristic in the current politics, and the management of water resources implies in the balance equally between the available flow and the flow of demand, or either, in the flow measurement. From 2004 the users of water resources are obliged to declare the caught volumes of water, is the annual declaration of use of water resources. The quality of the measured flow depends on the measurement techniques, and one of the main intervening factors is the condition of installation of the flowmeter. The evaluation of an electromagnetic flowmeter in practical conditions of installation was developed experimentally in this work. The electromagnetic flowmeter was installed in four different situations and the gotten values of flow measurement had been compared with the ones of two flowmeters installed adequately, an Venturi fi owmete r and an Ultrasonic flowmeter. The evaluation had been developed in a work-bench in the Laboratory of Hidraulical and Mechanic of fluid of the College of Civil Engineering of the Unicamp. For the configuration with the electromagnetic flowmeter installed downstream of a 90° elbow of short ray, the maximum deviation was of 0,742% with a 0,27% uncertainty. For the configuration with the electromagnetic flowmeter installed downstream of a two 90° elbow of short ray, the maximum deviation was of 0,447% with a 0,74% uncertainty. For the configuration with the installed electromagnetic flowmeter downstream a drawer valve, with 50% of opening, the maximum deviation was of a -2,046% and uncertainty of 0,50%. The gotten results show clearly that the condition of installation of the flowmeter front to the singularity of the tubing affects its performance. The values of deviation indication can be considered low or high, depending on the demanded accuracy of the flowmeter inside of the system
Mestrado
Recursos Hidricos
Mestre em Engenharia Civil
Silva, Felipe Carvalho da. "Análise comparativa de medidor de vazão em flare por tecnologia ótica e pitometria utilizando túnel de vento." Universidade Federal do Espírito Santo, 2012. http://repositorio.ufes.br/handle/10/6230.
Full textWith recent discoveries by the oil industry related to the reserves in Brazilian pre-salt, flow measurement technology is being re-evaluated in view of the large CO2 concentrations found in these reserves. A technology that has accuracy levels similar to those obtained with flow meters currently used and also measures independent characteristics to the composition and thermodynamic properties of gases is optical flow measurement velocimetry (OFM). The present work is related to experimental study, comparison of the speed readings from Pitot tube flow meters and optical velocimetry. This experimental study consists of qualifying and quantifying the velocity profiles among the possible configurations of flow in the wind tunnel, proposing methodology using flow conditioners and damping of the readings obtained with the Pitot tube, and analysis of readings taken with the optical sensor to evaluate the device installation effects in the results. The results indicate that transit-time optical flow meters for medium to high speed levels, could provide readcohesive flow even in a misalignment of up to ± 5 °, although it appears in the installation manual of the manufacturer guarantees of results meter when a misalignment of at most up to ±2º. Regarding the optical sensor intrusive effect in the readings simultaneous with the Pitot tube, it is perceived, in general, from approximately Re> 2,05x105, the intrusive effect of this influence is suppressed by other effects. Finally, for a proper flow study through Pitometry in order to make the comparison with the optical flow metering and achieve satisfactory results with the Pitot tube, the use of specific devices of flow conditioning and damping of the measured values had to be made
Com as recentes descobertas da indústria petrolífera brasileira, relacionadas às reservas no pré-sal, a tecnologia de medição de vazão está sendo reavaliada, tendo em vista as grandes concentrações de CO2 encontradas nessas reservas. A tecnologia de medição de vazão por velocimetria óptica (OFM) possui níveis de precisão semelhantes aos obtidos com os medidores de vazão utilizados atualmente. Essa tecnologia possui as características de independência com relação à composição química e às propriedades termodinâmicas dos gases. O presente trabalho se dedica ao estudo experimental de comparação das leituras de velocidade entre tubo de Pitot e medidor de vazão por velocimetria óptica. Para isso foi efetuada qualificação e quantificação dos perfis de velocidades em escoamento no túnel de vento, propondo metodologia de uso de retificadores de fluxo e amortecimento das leituras obtidas com o tubo de Pitot, e análises de leituras realizadas com o sensor óptico visando avaliar os efeitos de instalação do dispositivo nos resultados obtidos. Os resultados indicam que medidores de vazão ópticos por tempo de trânsito, para níveis médios e altos de velocidade, podem fornecer a leitura esperada da vazão mesmo estando num desalinhamento de ±5º, apesar de constar no manual de instalação do fabricante garantia destes resultados do medidor quando num desalinhamento de, no máximo, até ±2º. Com relação ao efeito intrusivo do sensor óptico nas leituras simultâneas com o tubo de Pitot, percebe-se, em geral, que a partir de aproximadamente Re> 2,05x105, o efeito intrusivo desta influência foi suprimido por outros efeitos. Por fim, para uma devida caracterização do escoamento por meio de pitometria, a fim de efetuar a comparação com a medição Laser, e alcançar satisfatórios resultados com o tubo de Pitot, foi necessário fazer uso de dispositivos específicos como retificadores de fluxo e de amortecimento (damping) dos valores medidos
SILVA, F. C. "Análise Comparativa da Medição de Vazão em Flare Por Tecnologia Ótica e Pitometria Utilizando Túnel de Vento." Universidade Federal do Espírito Santo, 2012. http://repositorio.ufes.br/handle/10/4170.
Full textCom os recentes descobertas da indústria petrolífera brasileira relacionadas às reservas no pré-sal, a tecnologia de medição de vazão está sendo re-avaliada, tendo em vista as grandes concentrações de CO2 encontradas nessas reservas. Uma tecnologia que possui níveis de precisão semelhantes aos obtidos com os medidores de vazão utilizados atualmente e que possui as características de independência com relação à composição e propriedades termodinâmicas dos gases é a tecnologia de medição de vazão por velocimetria óptica (OFM). O presente trabalho se dedica a estudo experimental, de comparação das leituras de velocidade entre tubo de Pitot e medidor de vazão por velocimetria óptica. Para isso foi efetuada qualificação e quantificação dos perfis de velocidades dentre as configurações possíveis de escoamento no túnel de vento, propondo metodologia de uso de retificadores de fluxo e amortecimento das leituras obtidas com o tubo de Pitot, e análises de leituras realizadas com o sensor óptico visando avaliar os efeitos de instalação do dispositivo nos resultados obtidos. Os resultados indicam que medidores de vazão ópticos por tempo de trânsito, para níveis médios e altos de velocidade, podem fornecer leitura coesa da vazão mesmo estando num desalinhamento do até ±5º, apesar de constar no manual de instalação do fabricante, garantia destes resultados do medidor quando num desalinhamento de, no máximo, até 2%. Com relação ao efeito intrusivo do sensor óptico nas leituras simultâneas com o tubo de Pitot, percebe-se, em geral, que a partir de aproximadamente Re>205x103, o efeito intrusivo desta influência foi suprimido por outros efeitos. Por fim, temos que para uma devida caracterização do escoamento por meio de pitometria, para comparação com a medição Laser, e alcançar satisfatórios resultados com o tubo de Pitot foi necessário fazer-se uso de dispositivos específicos de retificadores de fluxo e de amortecimento (dumping) dos valores medidos. Palavras-chave: medidor de vazão por velocimetria óptica (OFM), Laser two focus (L2F), pitometria, Pré-sal.
Camapum, Filho Nicanor Alencar [UNESP]. "Avaliação de medidores com múltiplas tomadas de pressão na macromedição em sistemas de água." Universidade Estadual Paulista (UNESP), 2007. http://hdl.handle.net/11449/98100.
Full textPROPG
Este trabalho teve o objetivo de avaliar os medidores de vazão com uma ou múltiplas tomadas de pressão em sistemas de água. Esses medidores de vazão são de fácil construção, utilizando materiais de baixo custo, podem ser instalados em locais que apresentem perfis de velocidades axialmente assimétricos em decorrência da existência de singularidades e/ou incrustações internas. Este estudo também foi idealizado para auxiliar os programas de redução de perdas físicas de água, uma vez que existe uma demanda reprimida na instalação de medidores de vazão em redes públicas de abastecimento. O trabalho foi desenvolvido em escala real nas instalações da ETA de Presidente Prudente-SP que abastece a zona de distribuição denominada de Alto ETA. Como padrão de medição foi utilizado um tubo de Pitot do tipo Cole, calibrado em túnel de vento pelo IPT. Além da aferição em diversos perfis de velocidade, medidores de múltiplos furos foram instalados em vários locais da rede, o que proporcionou uma verificação do comportamento do medidor em relação à variação do tipo de materiais e diâmetros das redes de abastecimento e uma avaliação geral do seu emprego em condições reais de uso em sistemas de abastecimento público. Os resultados demonstram que o medidor multifuros foi menos sensível à variação do perfil de velocidades, ou seja, a utilização da curva de calibragem obtida em condições ideais numa situação de perfil assimétrico levou a erros de medição menores que os obtidos com medidor de tomada única. A possibilidade de contar com um medidor de vazão adequado às condições brasileiras, de baixo custo e facilidade de construção, abre perspectivas para alavancar os programas de redução de perdas físicas de água, uma vez que existe uma grande demanda reprimida na instalação de medidores de vazão em redes de abastecimento público.
This work had the objective of evaluating the flow meters with one or multiple orifices in water supply systems. Those flow meters are of easy construction, using inexpensive materials, and can be installed in places that present asymmetric velocity profiles as a consequence the existence of singularities and internal incrustations. This study was also conceived to aid the programs of reduction of physical losses of water, since a repressed demand for flow meters exists in water distribution systems. The work was developed in real scale in the Water Treatment Station - ETA of Presidente Prudente city-SP, that provisions the zone of distribution denominated High ETA. The measurement standard was a Pitot-Cole meter calibrated in wind tunnel by IPT. Besides calibration in several velocity profiles, meters of multiple orifices were installed at several places of the net, that provided a verification of the behavior of the meter related to the variation of the type of material and diameters of water distribution systems and a general evaluation of its employment in real conditions of use in public supply systems. The results demonstrate that the multi-port meter was less sensitive to the variation of the velocity profiles, in other words, the use of the calibration curve obtained in ideal conditions in a situation of asymmetric velocity profiles, led to smaller measurement errors than that obtained with a meter of only one orifice. The possibility to count on a flow meter adequate to the Brazilian conditions, inexpensive and easily constructed, opens perspectives for support the programs of reduction of physical losses of water, since there is a great unsatisfied demand for flow meters in water public supply systems.
Paz, Elson Francisco da. "Sistema baseado em medidor de pressão diferencial para determinação em linha de vazões de produção em poços de petróleo." Universidade de São Paulo, 2010. http://www.teses.usp.br/teses/disponiveis/3/3150/tde-28022011-161651/.
Full textThe oil and gas industry has been working to develop methods to monitor and control the fluid production in the wells. For this purpose, specific equipments are developed for measuring stream flows. This work presents a system based on differential pressure (or obstruction) flow meters (orifice plates, Venturis and nozzles) for online determination of production flows (oil, gas and water) in oil wells. Starting from the mass and momentum conservation equations for one-dimensional, isothermal flow and considering incompressible phases without phase change, homogenized liquid phases and constant slip between gas and liquid phases, a general relationship between total mass flow and pressure drop is derived. Using Chisholmts correlation for the slip, a comparison is made between the results obtained with the homogeneous model and the constant slip model. Through a characterization of the production fluids in steady state and using the black oil model for the oil-gas system, the production flows are determined at the reference condition. A validation is made between results obtained with the model and experimental data obtained in a rig at Aracaju (Sergipe) and in wells at Urucu (Amazonas). The comparison with experimental results shows that the predictions made with the slip model may be considered satisfactory, taking into account that the model was developed independently, without parameters adjusted from the experimental data.
Bernardo, Giovanni Francisco. "Método para instalação robusta do sensor medidor de vazão mássica de ar (MAFS) em sistemas de admissão de ar para motores de combustão interna." Universidade de São Paulo, 2010. http://www.teses.usp.br/teses/disponiveis/3/3149/tde-23122014-111806/.
Full textThe usage of Mass Air Flow Sensor (MAFS) to control the mass air flow intake by the internal combustion engine is relatively new in Brazil. Among the vehicles sold in the Brazilian market it is possible to find a number of examples that apply this technology. It is believed, however, that this sensor will soon be embraced by all domestic vehicle manufacturers. This document presents a practical methodology for robust installation of this sensor in air intake systems for a vehicle internal combustion engine. This methodology was based on recent development projects of air intake systems developed by one of the main Brazilian companies that use this type of sensor to help the electronic control system to manage the engine. This work also includes information about the main validation tests for installing the sensor in the vehicle air intake systems, as well as some of the practices adopted in the implementation of the development process. There will also be addressed the effects of modifications in the intake systems and how these modifications affect the results.
Barone, Marcelo Aiolfi. "Análise experimental sobre a utilização de sensores infravermelhos em provadores de vazão de fluidos claros." Universidade Federal do Espírito Santo, 2012. http://repositorio.ufes.br/handle/10/6231.
Full textCoordenação de Aperfeiçoamento de Pessoal de Nível Superior
Este trabalho utiliza um protótipo de escala laboratorial do medidor primário pipe prover de modo a avaliar a sua conformidade com os requisitos estabelecidos por normas técnicas e examinar a incerteza da medição da vazão realizados, além de verificar a reprodutibilidade das medições, testes com esferas de diferentes diâmetros, a influência de parâmetros operacionais tais como a variação da pressão de operação e comparação com o teste gravimétrico. O protótipo é feito de tubos plástico com dimensões definidas estatisticamente. Dentro do tubo, uma esfera de elastômero interferente é impulsionada por um escoamento fornecido por uma bomba centrífuga. O sistema de detecção usa sensores de luz infravermelha capaz de detectar a passagem das esferas sem causar interferência ou bloqueio na tubulação. O sistema de aquisição de dados é automático e registra o tempo de trânsito da esfera através de cada pulso de sinal detectado bem como os pulsos gerados por um medidor calibrado tipo turbina, como comparação da avaliação das incertezas de processo utilizando o desempenho da técnica dos sensores infravermelhos
The work uses a laboratory scaled prototype of primary pipe prover flowmeter in order to assess conformity with the requirements established by technical standards and examine the uncertainties of flow measurement performed, besides to check the reproducibility of measurements, tests with spheres of different diameters, the influence of operating parameters such as operating pressure variation and comparison with gravimetric test. The prototype is plastic tubing and considering statically defined dimensions. Inside tubing, an interfering elastomer sphere is driven by flow provided by a centrifugal pump. The detection system uses infrared light sensors able to detect the spheres passage causing pipeline interference or blockage. The acquisition data system is automatic and records the sphere transit time through each pulse signal detected as well as the pulses generated by a calibrated turbine meter, as comparison of the evaluation of process uncertainties using the technique performance with infrared sensors
Mammana, Suelene Silva. "Microbocais sônicos de diamante." Universidade de São Paulo, 2002. http://www.teses.usp.br/teses/disponiveis/43/43134/tde-13122013-143319/.
Full textIn this work an original method for the fabrication of diamond micronozzles with converget-divergent profile is presented. The method uses the deposition of polycrystalline diamond over a mold, which is subsequently removed. The referred molds are tungsten wires patterned by means of an electrolytic etching procedure in a way that the divergent-convergent profile is generated. The main motivation for producing such micronozzles is its application as passive flow controllers and flow meters elements when operating under critical flow conditions. The micronozzles produced here were tested in order to determine the critical flow parameters that are necessary for its operation, as passive flow controllers and flow meters elements. The critical flow parameters (critical mass flow rate, critical pressure ratio and critical volumetric flow rate), the Reynolds number range and the discharge coefficient were determined for all the microdevices produced. The Reynolds number for the microdevices was found to be in the range of 1x10 POT.3-7x10 POT.4. For instance, the diamond micronozzle with smaller throat diameter, (16+/-1)x10mum, presented critical mass flow rate of (0,344+0,006)g/min, critical volumetric flow rate of (314+/-5)cm POT.3/min and discharge coefficient of (1,27+/-0,19). Therefore, diamond micronozzles were successfully fabricated with convergent-divergent profile and the critical flow parameters necessary for its operation, as passive flow controllers and flow meters elements, were determined.
Horigoshi, Francis Massashi. "Uso de sensor efeito Hall para medição da vazão de fluidos no processo de produção de palatabilizantes a base de proteína animal em escala piloto." Universidade de São Paulo, 2016. http://www.teses.usp.br/teses/disponiveis/74/74134/tde-28112016-135201/.
Full textFlowmeters contribute significantly to the industrial optimization where mass continuous displacement is an integral part of the production system, is therefore crucial for the industry allowing standardize products and automate actions reducing human labor and minimizing errors. This is the case of the production of flavors, substances produced from the enzymatic hydrolysis of animal protein to impart flavor and aroma to food, where there is a continuous mass displacement with fluids dosage triggered in several process steps. They can point out two main steps: a step where dosing occurs alkaline solutions for enzymatic hydrolysis and acidification stage which takes place to ensure the microbiological safety of the product. At work in question was developed and analyzed a turbine flowmeter for sensing via Hall effect to determine the volumetric flow fludos in the production of palatability process. The system used to assess the flow meter was developed on a pilot scale. The meter calibration allowed to calculate the K factor (the ratio meter) for both water where the ratio was 5.5, and for palatability, where the coefficient was calculated 7. From the data obtained by the flowmeter one can observe a high degree of correlation of the data. The flowmeter is made effective for the tested fluids (water and palatability); and with an accuracy of ± 2%, there is shown a viable alternative for the production of flavors process.
Borg, Denis. "Implementação de uma rede neural em ambiente foundation fieldbus para computação de vazão simulando um instrumento multivariável." Universidade de São Paulo, 2011. http://www.teses.usp.br/teses/disponiveis/18/18153/tde-29072011-100528/.
Full textThis dissertation proposes the development of an artificial neural network (ANN) directed to foundation fieldbus environment for calculation of flow in closed ducts. The proposed methodology uses measurements of pressure, temperature and differential pressure, which are usually available in industrial plants. The main motivation of the use of neural networks lies in their low cost and simplicity of implementation, which allows the use of standard fieldbus blocks by just making the method independent of the manufacturer. It was used a multilayer perceptron network with backpropagation training and algorithm from Levenberg-Marquardt. The training was programmed in the software Matlab TM. The architecture of the ANN was determined by empirical methods by varying the number of neurons and neural layers until it reaches an acceptable error. After such trainings, it was developed a program to perform the flow calculations in an foundation fieldbus environment using Emerson Process Management\'s DeltaV TM software. The results were obtained with an average relative error of flow rate of 1.43% for the first scenario using an orifice plate and air as a process fluid, and 0.073% for a second scenario using an orifice plate and natural gas as the fluid related to the values obtained from Rosemount 3095MV TM multivariable instrument. The values of error found validate the method developed in this dissertation.
Figueroa, Teodora Pinheiro. "Estudo sobre a viabilidade da tomografia eletromagnética na medição do perfil de velocidades de escoamentos monofásicos em dutos." Universidade de São Paulo, 2005. http://www.teses.usp.br/teses/disponiveis/18/18135/tde-20122006-103316/.
Full textThis work presents a prospective study on the development of an intelligent electromagnetic flow meter intended to determine output based on the reconstruction of velocity profile using tomographic techniques. As a result, the flow meter will be able to correct the output measure through the integration of the right velocity profile produced by tomography. The tomographic reconstruction technique utilized is based on the definition of an error functional generated from the difference between voltages simulated numerically for a experimental condition, being known the parameters which define the velocity within the pipe and approximate voltages simulated numerically for approaches of these parameters. In this work the physical model of the electromagnetic flow meter is based on a number of electrodes flush mounted on pipe walls and under a specific strategy of excitement, without electrical current input and considering the magnetic field uniform. From the expansion of the error functional over a set of known functions an error surface is generated. The characteristics of the pathology of this surface require other types of optimization techniques. Traditional optimization techniques are not viable since the search stops at the first local minimum. This convergence to local minimums is justified due to the presence of flat regions and valleys presenting several local minimums around the global minimum point (or point relative to the optimum parameters of velocity). Due to this fact techniques based on evolutionary algorithms are tested and presented for a series of cases demonstrating the usefulness of our research.
Martins, Ramon Silva. "Simulaçõeses numéricas de efeitos de acidentes de linha causados por curvas à montante de medidores de vazão por ultrassom de um canal por tempo de trânsito para gás de flare." Universidade Federal do Espírito Santo, 2012. http://repositorio.ufes.br/handle/10/6228.
Full textOil and gas industry requires accurate flow measurements since they are stated by law. Nevertheless, curves and other obstacles are commonly found in such industry field, which may affect the quality of flow measurement due to flow disturbances, such as swirl and velocity profile asymmetries. Single-path ultrasonic flow meters are often used in flare gas installations, despite being sensitive to such disturbances. The present work use commercial CFD codes to obtain disturbed flow fields downstream from single and double elbow pipe installations, aiming to investigate both magnitude and behaviour of such effects on ultrasonic flow measurement. Numerical integration is applied for several acoustic path arrangements, simulating single-path ultrasonic flow meters in different situations in order to evaluate its correction factor deviation under disturbed conditions. Reynolds numbers from 1X10 4 to 2 X10 6 are considered. Transducers mounting angles from 0° to 180° are tested and axial positions up to 80D downstream from the curve are evaluated. Results indicate that single-path ultrasonic flow meters are sensitive to installation effects. Correction factor deviations usually showed to be significantly higher than 2% for axial positions shorter than 20D, as recommended by several manufacturers or regulations. Nevertheless, deviations may reach 0.01% in some specific configurations, which suggests that ultrasonic flow measurement might be improved by rearranging flow meter device in favourable angular position and mainly by implementation of specific functions for correction factors under disturbed conditions
A indústria de petróleo e gás requer medições de vazão de baixa incerteza, uma vez que são estabelecidas por lei. Contudo, curvas e outros obstáculos são comumente encontrados nesse cenário e podem afetar a qualidade da medição de vazão em função de perturbações no escoamento, tais como swirl e assimetrias no perfil de velocidades. Medidores de vazão por ultrassom de um canal são frequentemente utilizados em instalações de gás de queimadores, apesar de serem sensíveis a tais perturbações. O presente trabalho usa códigos comerciais de CFD para obter o escoamento à jusante de instalações com uma curva e duas curvas, visando a investigar a magnitude e o comportamento de tais efeitos na medição de vazão. Integração numérica é utilizada para diversos arranjos de caminho acústico, simulando medidores de vazão por ultrassom de um canal em várias condições para avaliar o desvio do fator de correção em escoamentos perturbados. Números de Reynolds de 1×10 4 a 2×10 6 são considerados. Ângulos de montagem dos transdutores de 0° a 180° são testados e posições axiais até 80D à jusante do obstáculo são avaliadas. Os resultados indicam que medidores de vazão por ultrassom são sensíveis aos efeitos de acidente de linha. O desvio do fator de correção mostra-se, em geral, consideravelmente maior que 2% em distâncias menores que 20D, conforme recomendado por alguns fabricantes e por leis. Não obstante, tais desvios podem atingir 0,01% em algumas configurações específicas, o que sugere que a medição de vazão por ultrassom pode ser melhorada pelo rearranjo do aparato em posição angular favorável e, principalmente, pela implementação de funções específicas para fatores de correção em condições perturbadas
Pinheiro, Luiz Fernando. "O controle fiscal eletrÃnico da produÃÃo de bebidas: uma anÃlise setorial sob a perspectiva do desempenho da arrecadaÃÃo do ICMS do estado do Cearà no perÃodo de 2002 a 2011." Universidade Federal do CearÃ, 2013. http://www.teses.ufc.br/tde_busca/arquivo.php?codArquivo=14520.
Full textO objetivo deste estudo foi investigar o efeito da implantaÃÃo do controle fiscal eletrÃnico da produÃÃo de bebidas composto pelo Sistema de MediÃÃo de VazÃo â SMV e pelo Sistema de Controle de Bebidas - SICOBE, sobre o nÃvel da arrecadaÃÃo do ICMS da atividade econÃmica da fabricaÃÃo de cervejas e refrigerantes do Estado do CearÃ. Para tanto, utilizouse os seguintes parÃmetros: a base de dados da arrecadaÃÃo mensal de ICMS, a receita do imposto sobre produtos industrializados â IPI, o nÃmero de postos de trabalho ocupados na indÃstria e a quantidade de energia elÃtrica utilizados na atividade industrial das empresas do setor de bebidas sediadas no Cearà do perÃodo de 2002 a 2011. Essas bases sÃo compostas de duas categorias de contribuintes: indÃstrias de bebidas quentes e indÃstrias de bebidas frias. Utilizou-se a metodologia aplicada aos experimentos naturais usando a tÃcnica diferenÃa da diferenÃa. Como resultado foi observado que a introduÃÃo do controle eletrÃnico da produÃÃo gerou um incremento significativo na arrecadaÃÃo do ICMS das indÃstrias de bebidas no Estado do CearÃ.
The aim of this study was to investigate the effect of electronic fiscal control of the production of beverage composed by the Flow Measurement System - SMV and the Liquor Control System â Sicobe, on the level of the collection of ICMS, of beers and soft drinks manufactured at the state of CearÃ. We used the the database of beverage factories of the state of Cearà in the period of 2002 to 2011 on following parameters, the monthly collection of ICMS, the amount of collect tax over industrialized products â IPI, the number of jobs and the amount of electricity consumption. The industries were classified into two categories of taxpayers: the hot beverage and cold beverages industries. We used the methodology difference of difference, commonly applied to natural experiments.