To see the other types of publications on this topic, follow the link: Mehrschichtig.

Dissertations / Theses on the topic 'Mehrschichtig'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 dissertations / theses for your research on the topic 'Mehrschichtig.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

Ouyang, Wuye. "Dispersed and deposited polyelectrolyte complexes and their interactions to chiral compounds and proteins." Doctoral thesis, Saechsische Landesbibliothek- Staats- und Universitaetsbibliothek Dresden, 2009. http://nbn-resolving.de/urn:nbn:de:bsz:14-ds-1233841492089-61523.

Full text
Abstract:
Polyelectrolyte complexation is a rapidly growing field with applications in functional multilayer (PEM) and nanoparticle (PEC) generation, where PEM films are deposited using Layer-by-Layer technique initiated by Decher and PECs are prepared using mixing-centrifugation technique initiated by our group. Its advantages (e.g. easy preparation) result in various applications in aqueous solution, especially in pharmaceutical and biomedical fields. Therefore, the objectives in this study are to explore interesting applications of polyelectrolyte complexation in the field of low molecular chiral compound and high molecular protein binding. Due to the rapidly growing demands for preparing optically pure compounds in the pharmaceutical field, herein, enantiospecific PEM and PEC were prepared using chiral polyelectrolytes (e.g. homo-polypeptide) and their ability of chiral recognition was investigated by ATR-FTIR, UV/Vis etc.. Chiral PEM and PEC showed pronounced enantiospecificity for both small (amino acids, vitamin) and large (protein) chiral compounds. This chiral recognition is performed by a diffusion process of chiral compounds into PEM based on the structures of chiral selector (PEM, PEC) and chiral probes (chiral compounds). However, the influences, e.g. pH value, ionic strength, surface orientation etc., were found to affect significantly the enantiospecificity. Beside planar substrates, porous membranes (e.g. PTFE) were modified using chiral PEM and successfully applied in enantiospecific permeation. Additionally, protein binding properties of PEC particle dispersions or PEC particle films were also studied. Due to the properties of polyelectrolytes used for PEC (e.g. molecular weight, charge density) and proteins (e.g. isoelectric point, size, hydrophobicity), PEC showed different uptake characteristics towards different proteins. Electrostatic and hydrophobic interaction as well as counterion release force were considered as possible driving forces for protein binding.
APA, Harvard, Vancouver, ISO, and other styles
2

Ouyang, Wuye. "Dispersed and deposited polyelectrolyte complexes and their interactions to chiral compounds and proteins." Doctoral thesis, Technische Universität Dresden, 2008. https://tud.qucosa.de/id/qucosa%3A23825.

Full text
Abstract:
Polyelectrolyte complexation is a rapidly growing field with applications in functional multilayer (PEM) and nanoparticle (PEC) generation, where PEM films are deposited using Layer-by-Layer technique initiated by Decher and PECs are prepared using mixing-centrifugation technique initiated by our group. Its advantages (e.g. easy preparation) result in various applications in aqueous solution, especially in pharmaceutical and biomedical fields. Therefore, the objectives in this study are to explore interesting applications of polyelectrolyte complexation in the field of low molecular chiral compound and high molecular protein binding. Due to the rapidly growing demands for preparing optically pure compounds in the pharmaceutical field, herein, enantiospecific PEM and PEC were prepared using chiral polyelectrolytes (e.g. homo-polypeptide) and their ability of chiral recognition was investigated by ATR-FTIR, UV/Vis etc.. Chiral PEM and PEC showed pronounced enantiospecificity for both small (amino acids, vitamin) and large (protein) chiral compounds. This chiral recognition is performed by a diffusion process of chiral compounds into PEM based on the structures of chiral selector (PEM, PEC) and chiral probes (chiral compounds). However, the influences, e.g. pH value, ionic strength, surface orientation etc., were found to affect significantly the enantiospecificity. Beside planar substrates, porous membranes (e.g. PTFE) were modified using chiral PEM and successfully applied in enantiospecific permeation. Additionally, protein binding properties of PEC particle dispersions or PEC particle films were also studied. Due to the properties of polyelectrolytes used for PEC (e.g. molecular weight, charge density) and proteins (e.g. isoelectric point, size, hydrophobicity), PEC showed different uptake characteristics towards different proteins. Electrostatic and hydrophobic interaction as well as counterion release force were considered as possible driving forces for protein binding.
APA, Harvard, Vancouver, ISO, and other styles
3

Tuerk, Tobias. "Mehrschicht-Spiral-Computertomographie." Diss., lmu, 2008. http://nbn-resolving.de/urn:nbn:de:bvb:19-80149.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Ellerbrock, Thomas M. "Multilayer neural networks learnability, network generation, and network simplification /." [S.l. : s.n.], 1999. http://deposit.ddb.de/cgi-bin/dokserv?idn=958467897.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Walde, Janette F. "Design künstlicher neuronaler Netze : ein Leitfaden zur effizienten Handhabung mehrschichtiger Perzeptrone /." Wiesbaden : Dt. Univ.-Verl, 2005. http://deposit.ddb.de/cgi-bin/dokserv?id=2610939&prov=M&dok_var=1&dok_ext=htm.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Prinz, Robert. "Ausfallsichere mehrschichtige Netze mit dynamischen Link-Ressourcen." kostenfrei, 2010. https://mediatum2.ub.tum.de/node?id=811568.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Motavalli, Masoud. "Das Verhalten mehrschichtiger Verbundrohre unter Innendruck /." Zürich, 1991. http://e-collection.ethbib.ethz.ch/show?type=diss&nr=9597.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Wagner, Hendrik. "Modularisierung von neuronalen Netzen." [S.l. : s.n.], 1999. http://deposit.ddb.de/cgi-bin/dokserv?idn=957576080.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Bohner, Georg. "Schlaganfall-Bildgebung mittels Mehrschicht-Spiral-CT." [S.l.] : [s.n.], 2004. http://deposit.ddb.de/cgi-bin/dokserv?idn=974114308.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Bohner, Georg. "Schlaganfall-Bildgebung mittels Mehrschicht-Spiral-CT." Doctoral thesis, Humboldt-Universität zu Berlin, Medizinische Fakultät - Universitätsklinikum Charité, 2005. http://dx.doi.org/10.18452/15190.

Full text
Abstract:
Es wurde der Einsatz der Mehrschicht-Spiral-CT (MS-CT) zur zerebralen Perfusionsbildgebung und zur zerviko-zerebralen Angiographie bei Schlaganfallpatienten evaluiert. Bei 52 Patienten mit klinischen Zeichen einer akuten Ischämie wurde im Mittel 3,4 Stunden nach Symptombeginn an einem MS-CT Gerät eine CT-Perfusion (CTP) durchgeführt. Parameterbilder der zerebralen Blutperfusion (CBP), des zerebralen Blutvolumens (CBV) und der mittleren Transitzeit (MTT) wurden generiert, Perfusionsstörungen ermittelt und mit bildgebenden sowie klinischen Verlaufskontrollen korreliert. Eine CT-Angiographie (CTA) wurde initial bei 12 Patienten angewandt, um die Eignung des Untersuchungsprotokolls zu prüfen. Darüber hinaus wurden bei 45 Patienten mit Zeichen einer akuten zerebrovaskulären Insuffizienz die Ergebnisse der CTA mit denen anderer bildgebender Modalitäten (Magnetresonanz-Angiographie, digitale Subtraktionsangiographie, Dopplerultraschall) verglichen. Perfusionsbilder konnten von 44 Patienten generiert werden, hiervon entwickelten 22 Patienten einen im Verlauf gesicherten Infarkt. An Hand der MTT-Bilder konnten ischämische Veränderungen mit einer Sensitivität von 95 % erfasst werden, die Spezifität war mit 100 % für die CBV-Bilder am höchsten. Patienten mit Infarkt zeigten seitenvergleichend eine signifikante Reduktion der CBP in ischämischen Arealen. Die Ausdehnung der CBV Reduktion ergab die beste Korrelation mit dem endgültigen partiellen Infarktvolumen. Mit der CTA konnte anfänglich bei 12 / 12 Patienten, später bei 43 / 45 (96 %) eine umfassende Darstellung des zerviko-zerebralen Gefäßsystems erreicht werden, wobei in 22 Infarktpatienten die zu Grunde liegende Gefäßpathologie erkannt werden konnte. Das evaluierte Protokoll zur Perfusionsbildgebung mittels Mehrschicht-Spiral-CT ist zur frühzeitigen Erkennung und Quantifizierung einer akuten zerebralen Ischämie geeignet und bietet zusammen mit der CTA, welche das gesamte zerviko-zerebrale Gefäßsystem verlässlich visualisieren kann, die Möglichkeit einer umfassenden Bildgebung mittels MS-CT bei Schlaganfallpatienten.
The application of multi-slice spiral computed tomography (MS-CT) in the diagnostic assessment of stroke patients using cerebral perfusion imaging and cervicocerebral angiography was evaluated. Fifty-two patients with clinically suspected acute ischemia underwent CT perfusion (CTP), performed 3.4 hours, on average, after the onset of symptoms, by using MS-CT. Perfusion images of the cerebral blood perfusion (CBP), cerebral blood volume (CBV) and mean transit time (MTT) were calculated. The amount and extension of perfusion disturbances were measured and correlated with the outcome. CT angiography (CTA) was initially performed on twelve patients to verify the suitability of the examination protocol. In addition, forty-five patients with signs of acute cerebrovascular insufficiency underwent CTA. CTA findings were compared with those of other imaging modalities (magnetic resonance imaging, digital subtraction angiography, doppler ultrasonography). Of 44 patients in whom perfusion maps could be generated, 22 developed infarction confirmed at follow-up. On MTT-maps ischemic changes could be detected with the highest sensitivity (95%). Specificity was highest (100%) for CBV-maps. Patients with infarction showed significant reduction of CBP in ischemic tissue compared to the contra lateral hemisphere. Extension of CBV reduction showed the best correlation with final infarct volume. Initially in twelve out of twelve patients, later in 43 out of 45 (96%), the cervicocranial vascular system could be comprehensively visualized using CTA. In 22 stroke patients the underlying vascular pathology could be detected. CT perfusion using multi-slice CT is a suitable tool for the early identification and quantification of acute cerebral ischemia. Multi-slice CT angiography permits reliable visualization of the cervicocranial vascular system. Together these tools offer comprehensive assessment of stroke patients by means of multi-slice CT.
APA, Harvard, Vancouver, ISO, and other styles
11

Schleifer, Vanessa. "Zum Verhalten von raumabschliessenden mehrschichtigen Holzbauteilen im Brandfall /." Zürich : ETH, 2009. http://e-collection.ethbib.ethz.ch/show?type=diss&nr=18156.

Full text
APA, Harvard, Vancouver, ISO, and other styles
12

Gajicic, Mihael [Verfasser]. "Untersuchung der Fördereigenschaften von mehrschichtigen Zylinderaufzügen / Mihael Gajicic." Wuppertal : Universitätsbibliothek Wuppertal, 2019. http://d-nb.info/1206121645/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
13

Swertz, Ann-Christin [Verfasser]. "Elektronenmikroskopische Untersuchungen an mehrschichtigen Nanopartikeln / Ann-Christin Swertz." Wuppertal : Universitätsbibliothek Wuppertal, 2017. http://d-nb.info/1136872655/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
14

Kaufmann, Jörg [Verfasser]. "Beitrag zu anisotropiebedingten Koppeleffekten bei rotationssymmetrischen mehrschichtigen Faserverbundbauteilen / Jörg Kaufmann." München : Verlag Dr. Hut, 2014. http://d-nb.info/1063221404/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
15

Dewey, Marc [Verfasser]. "Mehrschicht-Computertomografie in der Diagnostik der koronaren Herzkrankheit / Marc Dewey." Berlin : Medizinische Fakultät Charité - Universitätsmedizin Berlin, 2008. http://d-nb.info/1027306411/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
16

Lenkeit, Daniel [Verfasser]. "Neuartige Fluoren-Copolymere für aus Lösung prozessierbare Mehrschicht-Bauelemente / Daniel Lenkeit." Wuppertal : Universitätsbibliothek Wuppertal, 2016. http://d-nb.info/1120339553/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
17

Jach, Cornelia [Verfasser]. "Einsatz der Dosismodulation in der Mehrschicht-Computertomographie der Kopf-/ Halsregion / Cornelia Jach." Berlin : Medizinische Fakultät Charité - Universitätsmedizin Berlin, 2008. http://d-nb.info/102282533X/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
18

Hoffmann, Karen. "Bewertung der globalen linksventrikulären Funktion: Vergleich der Mehrschicht-Spiral-CT mit der Angiokardiographie." Diss., lmu, 2005. http://nbn-resolving.de/urn:nbn:de:bvb:19-40583.

Full text
APA, Harvard, Vancouver, ISO, and other styles
19

Jungblut, Robert. "Der diagnostische Stellenwert des Mehrschicht-Spiral-CT bei Patienten mit Verdacht auf Darmischämie." [S.l.] : [s.n.], 2005. http://deposit.ddb.de/cgi-bin/dokserv?idn=974924768.

Full text
APA, Harvard, Vancouver, ISO, and other styles
20

Jungblut, Robert. "Der diagnostische Stellenwert des Mehrschicht-Spiral-CT bei Patienten mit Verdacht auf Darmischämie." Doctoral thesis, Humboldt-Universität zu Berlin, Medizinische Fakultät - Universitätsklinikum Charité, 2005. http://dx.doi.org/10.18452/15240.

Full text
Abstract:
Fragestellung: Wie nützlich ist das Mehrschicht-Spiral-CT bei der Diagnostik der Darmischämie? Studiendesign: Retrospektive Studie Patientenkollektiv: 112 Patienten, die in einem Zeitraum von drei Jahren bei Verdacht auf Darmischämie in einem Mehrschicht-Spiral-CT untersucht wurden. Ergebnis: Bei den 112 Verdachtsfällen handelte es sich in 26 Fällen um eine Darmischämie. Das CT erkannte davon 24 (92%), ein Fall wurde falsch negativ (4%) befundet und ein Fall (4%) wurde als unklar eingestuft. Von den 86 Fällen ohne Darmischämie wurden 77 (89%) korrekt erkannt, drei (4%) wurden falsch positiv befundet und 6 (7%) Fälle wurden als unklar eingestuft. Die Ergebnisse der bei manchen Patienten zusätzlich durchgeführten Sonografie – und Röntgenuntersuchungen waren erheblich schlechter (Sono: Sensitivität: , Spezifität: ; Röntgen: Sensitivität: , Spezifität: ). Die erhobenen Laborparameter (Leukozyten, Lactat, D-Dimere) waren zur Beurteilung, ob es sich um eine Darmischämie handelt, nicht spezifisch genug. Schlussfolgerung: Das Mehrschicht-Spiral-CT ist mit einer Sensitivität von 92% und einer Spezifität von 97% gut zur Erkennung einer Darmischämie geeignet. Unklare Fälle sind mit hoher Wahrscheinlichkeit nicht operationswürdig.
Objective: To verify the diagnostic importance of helical CT in the diagnosis of mesenteric ischemia. Design: Retrospective study Subjects: 112 patients, who where examined by helical CT during a 3-year-period, with suspected mesenteric ischemia. Main Outcome: 26 cases proved to be mesenteric ischemia. Helical CT was diagnostic in 24 (92%) cases, wrong in one (4%) case and uncertain in one (4%) case. No ischemia was correctly diagnosed in 77/86 (89%) cases, wrongly in three (4%) and 6 (7%) were uncertain. Sonografie and plain film radiographs were taken on some patients, but the results were unsatisfactory. Sonography: Sensitivity: 0%, specificy: 85,7%. Plain film radiographs sensitivity: 0%, specificy: 100%. Results of laboratory test were of little diagnostic value (white blood cell count, lactate, d-dimere). Conclusions: Helical CT is a valuable tool for detecting mesenteric ischemia with a sensitifity of 92% and a specificy of 97%. Suspected mesenteric ischemia which cannot be proved by helical CT are most probable non surgical cases.
APA, Harvard, Vancouver, ISO, and other styles
21

Gebhard, Patrick. "Emotionalisierung interaktiver virtueller Charaktere ein mehrschichtiges Computermodell zur Erzeugung und Simulation von Gefühlen in Echtzeit." Heidelberg AKA, 2009. http://d-nb.info/992824265/04.

Full text
APA, Harvard, Vancouver, ISO, and other styles
22

Neumann, Mirko. "Entwicklung von Verfahren zur Beurteilung des Tragverhaltens von mehrschichtigen Aussenwandelementen aus Betonen unterschiedlicher baustofflicher Kennwerte." [S.l. : s.n.], 1997. http://deposit.ddb.de/cgi-bin/dokserv?idn=958448264.

Full text
APA, Harvard, Vancouver, ISO, and other styles
23

Flaschenträger, David Verfasser], Tobias [Akademischer Betreuer] Melz, and Stephan [Akademischer Betreuer] [Rinderknecht. "Zuverlässigkeit von piezoelektrischen Mehrschicht-Aktoren in der Adaptronik / David Flaschenträger ; Tobias Melz, Stephan Rinderknecht." Darmstadt : Universitäts- und Landesbibliothek Darmstadt, 2017. http://d-nb.info/1137324066/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
24

Flaschenträger, David [Verfasser], Tobias Akademischer Betreuer] Melz, and Stephan [Akademischer Betreuer] [Rinderknecht. "Zuverlässigkeit von piezoelektrischen Mehrschicht-Aktoren in der Adaptronik / David Flaschenträger ; Tobias Melz, Stephan Rinderknecht." Darmstadt : Universitäts- und Landesbibliothek Darmstadt, 2017. http://d-nb.info/1137324066/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
25

Dierickx, Sebastian [Verfasser], and E. [Akademischer Betreuer] Ivers-Tiffée. "Charakterisierung, Modellentwicklung und Simulation von mehrschichtigen Brenngaselektroden in Festoxid-Brennstoffzellen / Sebastian Dierickx ; Betreuer: E. Ivers-Tiffée." Karlsruhe : KIT Scientific Publishing, 2019. http://d-nb.info/1200547993/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
26

Ziegler, Franz von. "Detektion, Quantifizierung und morphologische Charakterisierung atherosklerotischer Läsionen der Koronargefäße mit der kardialen Mehrschicht-Spiral-Computertomographie." Diss., lmu, 2007. http://nbn-resolving.de/urn:nbn:de:bvb:19-70128.

Full text
APA, Harvard, Vancouver, ISO, and other styles
27

Bohner, Georg [Verfasser], K. [Gutachter] Sator, R. [Gutachter] Kachel, and R. [Gutachter] Lehmann. "Schlaganfall-Bildgebung mittels Mehrschicht-Spiral-CT / Georg Bohner ; Gutachter: K. Sator, R. Kachel, R. Lehmann." Berlin : Humboldt-Universität zu Berlin, 2005. http://d-nb.info/1206190329/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
28

Rodenwaldt, Jens. "Magnetresonanztomographie, Mehrschicht-Spiral-CT und Elektronenstrahl-CT zur morphologischen und funktionellen Diagnostik der koronaren Herzkrankheit." Doctoral thesis, Humboldt-Universität zu Berlin, Medizinische Fakultät - Universitätsklinikum Charité, 2003. http://dx.doi.org/10.18452/13851.

Full text
Abstract:
Die Magnetresonanztomographie (MRT), die Mehrschicht-Spiral-Computertomographie (MSCT) und die Elektronenstrahl-Computertomographie (EBCT) sind nichtinvasive diagnostische Verfahren, welche die bisherige kardiale Bildgebung zumindest in Teilbereichen ersetzen oder ergänzen können. MR-Perfusions- und MR-Funktionsuntersuchungen konnten in der vorgelegten Arbeit direkte Parameter der myokardialen Vitalität regional erfassen. Die Signalintensitäten im Blut und im Herzmuskel dienten zur quantitativen Bestimmung der Myokardperfusion. Die Ortsauflösung ermöglichte eine Differenzierung der subendo- und der subepikardialen Durchblutung. Zusätzliche Streßuntersuchungen steigerten die Sensitivität des Verfahrens. Relativ geringgradige Koronarstenosen ließen sich durch vornehmlich subendokardial lokalisierte Perfusionsdefekte nachweisen. MR-Tagging- Funktionsanalysen konnten durch ein artifizielles Markierungsgitter zwischen endokardial lokalisiertem Narbengewebe und epikardial liegendem vitalem Gewebe differenzieren. Die Dehnungen, Stauchungen und Rotationen des Myokardverbandes wurden registriert und ausgewertet. Die MSCT und die EBCT wurden als Röntgenverfahren für die nichtinvasive Koronarangiographie verglichen. Bei der Definition der Gefäßkonturschärfe über die Anstiegssteilheit der CT-Dichtewerte zeigte sich eine bessere Abbildungsqualität der MSCT gegenüber der EBCT. Die Bestimmung der Segmenterkennbarkeit zeigte, dass mit der MSCT signifikant mehr erkannt werden konnten. Die vorgestellten kardialen MR- und CT-Untersuchungen konnten aus Gründen der Reproduzierbarkeit sowie aufgrund des Strahlenschutzes nur tierexperimentell durchgeführt werden. Die Validität der unterschiedlichen Tiermodelle ist in vorausgegangenen Studien belegt worden. Die in der Literatur verfügbaren Ergebnisse am Menschen bestätigen in vieler Weise die vorgelegten Daten.
Magnetic resonance imaging (MRI), multislice spiral computed tomography (MSCT), and electron-beam computed tomography (EBCT) are noninvasive imaging modalities that may supplement or in part even replace established diagnostic procedures for assessment of the heart. MRI perfusion and functional studies were shown to enable determination of direct parameters of regional myocardial vitality. The signal intensities of blood and myocardium served to quantify myocardial perfusion. The spatial resolution allowed for differentiating subendocardial and subepicardial perfusion. Additional stress tests improved the sensitivity of the procedure. Relatively low-grade coronary artery stenoses were identified by the presence of perfusion gaps primarily in subendocardial location. Functional analysis by means of MRI tagging using an artificial grid allowed for differentiating endocardial scar tissue from epicardial vital tissue. Extension, compression, and rotation of the myocardial complex were recorded and analyzed. MSCT and EBCT were compared as radiographic procedures for noninvasive coronary angiography. MSCT was found to be superior to EBCT in terms of image quality defined as vascular contour sharpness determined as the steepness of the increase in CT densities. Assessment of segment identification showed that significantly more segments were visualized by MSCT. The cardiac MRI and CT studies presented here could only be performed in animals because of the radiation exposure involved and to ensure reproducibility of the results. The validity of the different animal models used has been demonstrated in preceding studies. The results of the present animal experiments are in agreement with many of the human data published in the literature.
APA, Harvard, Vancouver, ISO, and other styles
29

Hempe, Matthias [Verfasser], Michael [Akademischer Betreuer] Reggelin, Matthias [Akademischer Betreuer] Rehahn, and Roland [Akademischer Betreuer] Schmechel. "Vernetzbare Funktionsmaterialien für die Anwendung in flüssigphasenprozessierten, mehrschichtigen OLEDs / Matthias Hempe ; Michael Reggelin, Matthias Rehahn, Roland Schmechel." Darmstadt : Universitäts- und Landesbibliothek Darmstadt, 2016. http://d-nb.info/1121781578/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
30

Gündogar, Ufuk. "Vergleich der Bildgüte bei der Niedrigdosis- Mehrschicht-Computertomographie der Lunge mit 4 Detektorzeilen und 64 Detektorzeilen." Diss., lmu, 2010. http://nbn-resolving.de/urn:nbn:de:bvb:19-115675.

Full text
APA, Harvard, Vancouver, ISO, and other styles
31

Schultz-Cornelius, Milan Kito [Verfasser], and Matthias [Akademischer Betreuer] Pahn. "Konzept zur Bemessung von unbewehrten Fassadenplatten aus Ultrahochleistungsbeton in mehrschichtigen Stahlbetonwandtafeln / Milan Kito Schultz-Cornelius ; Betreuer: Matthias Pahn." Kaiserslautern : Technische Universität Kaiserslautern, 2020. http://d-nb.info/1206589094/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
32

Schultz-Cornelius, Milan [Verfasser], and Matthias [Akademischer Betreuer] Pahn. "Konzept zur Bemessung von unbewehrten Fassadenplatten aus Ultrahochleistungsbeton in mehrschichtigen Stahlbetonwandtafeln / Milan Kito Schultz-Cornelius ; Betreuer: Matthias Pahn." Kaiserslautern : Technische Universität Kaiserslautern, 2020. http://d-nb.info/1206589094/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
33

Zander, Adolf. "Neuronale Netze zur Analyse von nichtlinearen Strukturmodellen mit latenten Variablen /." Wiesbaden : Wiesbaden : Deutscher Universitäts-Verlag ; Gabler, 2001. http://bvbr.bib-bvb.de:8991/F?func=service&doc_library=BVB01&doc_number=009236522&line_number=0001&func_code=DB_RECORDS&service_type=MEDIA.

Full text
APA, Harvard, Vancouver, ISO, and other styles
34

Stackelberg, Burkhard von. "Konstruktionsverfahren vorwärtsgerichteter neuronaler Netze." [S.l. : s.n.], 2003. http://www.bsz-bw.de/cgi-bin/xvms.cgi?SWB10790757.

Full text
APA, Harvard, Vancouver, ISO, and other styles
35

Westermann, Yvonne Nadine [Verfasser]. "Mehrschicht-Spiral-Computertomographie zur Quantifizierung von Aorten- und Mitralklappenstenosen : Vergleich mit Magnetresonanztomographie, Echokardiographie und Herzkatheter / Yvonne Nadine Westermann." Berlin : Medizinische Fakultät Charité - Universitätsmedizin Berlin, 2012. http://d-nb.info/102849484X/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
36

Harders, Hauke [Verfasser]. "Kardiale Mehrschicht Computertomographie : Eignung von „Niedrig-Kontrast-Datensätzen“ zur linksventrikulären Volumetrie bei Patienten mit hypertropher Kardiomyopathie variabler Ausprägung / Hauke Harders." Kiel : Universitätsbibliothek Kiel, 2017. http://d-nb.info/1130147800/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
37

Pahn, Matthias [Verfasser], Jürgen [Akademischer Betreuer] Schnell, and Peter [Akademischer Betreuer] Mark. "Beitrag zur Ermittlung von Schnitt- und Verformungsgrößen bei mehrschichtigen Stahlbetonwandtafeln mit Verbindungsmitteln aus glasfaserverstärktem Kunststoff / Matthias Pahn. Betreuer: Jürgen Schnell ; Peter Mark." Kaiserslautern : Universitätsbibliothek Kaiserslautern, 2011. http://d-nb.info/1017760268/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
38

Hoffstadt, Thorben [Verfasser], Jürgen [Akademischer Betreuer] Maas, Wolfgang H. [Gutachter] Müller, Jürgen [Gutachter] Maas, and Helmut F. [Gutachter] Schlaak. "Modellierung und Regelung von dielektrischen Mehrschicht-Elastomerwandlern / Thorben Hoffstadt ; Gutachter: Wolfgang H. Müller, Jürgen Maas, Helmut F. Schlaak ; Betreuer: Jürgen Maas." Berlin : Universitätsverlag der TU Berlin, 2020. http://d-nb.info/1222588404/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
39

Rodenwaldt, Jens [Verfasser], Dietbert [Gutachter] Hahn, and Walter [Gutachter] Heindel. "Magnetresonanztomographie, Mehrschicht-Spiral-CT und Elektronenstrahl-CT zur morphologischen und funktionellen Diagnostik der koronaren Herzkrankheit / Jens Rodenwaldt ; Gutachter: Dietbert Hahn, Walter Heindel." Berlin : Humboldt-Universität zu Berlin, 2003. http://d-nb.info/120767009X/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
40

Branschofsky, Mark Lars [Verfasser]. "Untersuchungen zum Einfluss verschiedener technischer Parameter in der Mehrschicht-Spiral-Computertomographie auf Bildqualität und Detektionsrate von endoluminalen Läsionen am Schweinedarmmodell / Mark Lars Branschofsky." Düsseldorf : Universitäts- und Landesbibliothek Düsseldorf, 2012. http://d-nb.info/1032037709/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
41

Hartmann, Dinah Maria [Verfasser]. "Computer-assistierte Diagnose zur Detektion von intrapulmonalen Rundherden in der Mehrschicht-Spiral Computertomographie : Evaluierung der Sensitivität in Bezug zur Rundherdgröße / Dinah Maria Hartmann." Aachen : Hochschulbibliothek der Rheinisch-Westfälischen Technischen Hochschule Aachen, 2011. http://d-nb.info/1016509642/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
42

Jungblut, Robert [Verfasser], B. [Gutachter] Hamm, H. J. [Gutachter] Schulz, and L. [Gutachter] Kopka. "Der diagnostische Stellenwert des Mehrschicht-Spiral-CT bei Patienten mit Verdacht auf Darmischämie / Robert Jungblut ; Gutachter: B. Hamm, H.-J. Schulz, L. Kopka." Berlin : Humboldt-Universität zu Berlin, 2005. http://d-nb.info/1207672688/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
43

Bayer, Anna Theresa [Verfasser], and Ulrich [Akademischer Betreuer] Schüller. "Herunterregulation des Mikro-RNA-Clusters auf Chromosom 19 (C19MC) in Tumorzellen eines embryonalen Tumors mit mehrschichtigen Rosetten (ETMR) in vitro / Anna Theresa Bayer ; Betreuer: Ulrich Schüller." München : Universitätsbibliothek der Ludwig-Maximilians-Universität, 2019. http://d-nb.info/1200852184/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
44

Kiedrowski, Helge von [Verfasser], Dieter [Gutachter] Horstkotte, and Hubert [Gutachter] Seggewiß. "Nichtinvasive Koronarangiographie : der klinische Nutzen der Mehrschicht Computertomographie basierten nichtinvasiven Koronarangiographie bei Patienten nach Bypassoperation / Helge von Kiedrowski ; Gutachter: Dieter Horstkotte, Hubert Seggewiß ; Medizinische Fakultät." Bochum : Ruhr-Universität Bochum, 2012. http://d-nb.info/1227707398/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
45

Bojdys, Michael Janus. "On new allotropes and nanostructures of carbon nitrides." Phd thesis, Universität Potsdam, 2009. http://opus.kobv.de/ubp/volltexte/2010/4123/.

Full text
Abstract:
In the first section of the thesis graphitic carbon nitride was for the first time synthesised using the high-temperature condensation of dicyandiamide (DCDA) – a simple molecular precursor – in a eutectic salt melt of lithium chloride and potassium chloride. The extent of condensation, namely next to complete conversion of all reactive end groups, was verified by elemental microanalysis and vibrational spectroscopy. TEM- and SEM-measurements gave detailed insight into the well-defined morphology of these organic crystals, which are not based on 0D or 1D constituents like known molecular or short-chain polymeric crystals but on the packing motif of extended 2D frameworks. The proposed crystal structure of this g-C3N4 species was derived in analogy to graphite by means of extensive powder XRD studies, indexing and refinement. It is based on sheets of hexagonally arranged s-heptazine (C6N7) units that are held together by covalent bonds between C and N atoms. These sheets stack in a graphitic, staggered fashion adopting an AB-motif, as corroborated by powder X-ray diffractometry and high-resolution transmission electron microscopy. This study was contrasted with one of many popular – yet unsuccessful – approaches in the last 30 years of scientific literature to perform the condensation of an extended carbon nitride species through synthesis in the bulk. The second section expands the repertoire of available salt melts introducing the lithium bromide and potassium bromide eutectic as an excellent medium to obtain a new phase of graphitic carbon nitride. The combination of SEM, TEM, PXRD and electron diffraction reveals that the new graphitic carbon nitride phase stacks in an ABA’ motif forming unprecedentedly large crystals. This section seizes the notion of the preceding chapter, that condensation in a eutectic salt melt is the key to obtain a high degree of conversion mainly through a solvatory effect. At the close of this chapter ionothermal synthesis is seen established as a powerful tool to overcome the inherent kinetic problems of solid state reactions such as incomplete polymerisation and condensation in the bulk especially when the temperature requirement of the reaction in question falls into the proverbial “no man’s land” of classical solvents, i.e. above 250 to 300 °C. The following section puts the claim to the test, that the crystalline carbon nitrides obtained from a salt melt are indeed graphitic. A typical property of graphite – namely the accessibility of its interplanar space for guest molecules – is transferred to the graphitic carbon nitride system. Metallic potassium and graphitic carbon nitride are converted to give the potassium intercalation compound, K(C6N8)3 designated according to its stoichiometry and proposed crystal structure. Reaction of the intercalate with aqueous solvents triggers the exfoliation of the graphitic carbon nitride material and – for the first time – enables the access of singular (or multiple) carbon nitride sheets analogous to graphene as seen in the formation of sheets, bundles and scrolls of carbon nitride in TEM imaging. The thus exfoliated sheets form a stable, strongly fluorescent solution in aqueous media, which shows no sign in UV/Vis spectroscopy that the aromaticity of individual sheets was subject to degradation. The final section expands on the mechanism underlying the formation of graphitic carbon nitride by literally expanding the distance between the covalently linked heptazine units which constitute these materials. A close examination of all proposed reaction mechanisms to-date in the light of exhaustive DSC/MS experiments highlights the possibility that the heptazine unit can be formed from smaller molecules, even if some of the designated leaving groups (such as ammonia) are substituted by an element, R, which later on remains linked to the nascent heptazine. Furthermore, it is suggested that the key functional groups in the process are the triazine- (Tz) and the carbonitrile- (CN) group. On the basis of these assumptions, molecular precursors are tailored which encompass all necessary functional groups to form a central heptazine unit of threefold, planar symmetry and then still retain outward functionalities for self-propagated condensation in all three directions. Two model systems based on a para-aryl (ArCNTz) and para-biphenyl (BiPhCNTz) precursors are devised via a facile synthetic procedure and then condensed in an ionothermal process to yield the heptazine based frameworks, HBF-1 and HBF-2. Due to the structural motifs of their molecular precursors, individual sheets of HBF-1 and HBF-2 span cavities of 14.2 Å and 23.0 Å respectively which makes both materials attractive as potential organic zeolites. Crystallographic analysis confirms the formation of ABA’ layered, graphitic systems, and the extent of condensation is confirmed as next-to-perfect by elemental analysis and vibrational spectroscopy.
Die vorliegende Arbeit befasst sich mit der Synthese und Charakterisierung neuer Allotropen und Nanostrukturen von Karbonitriden und berührt einige ihrer möglichen Anwendungen. Alle gezeigten, ausgedehnten, kovalent verbundenen Karbonitridgerüste wurden in einem ionothermalen Syntheseprozess – einer Hochtemperaturbehandlung in einem eutektischen Salzgemisch als ungewöhnlichem Lösungsmittel – aus einfachen Präkursormolkülen erzeugt. Der Kondensationsmechanismus folgt einer temperaturinduzierten Deaminierung und Bildung einer ausgedehnten, aromatischen Einheit; des dreifach substituierten Heptazines. Die Dissertation folgt vier übergreifenden Themen, beginnend mit der Einleitung in Karbonitridsysteme und der Suche nach einem Material, welches einzig aus Kohlenstoff und Stickstoff aufgebaut ist – einer Suche, die 1834 mit den Beobachtungen Justus von Liebigs „über einige Stickstoffverbindungen“ begann. Der erste Abschnitt zeigt die erfolgreiche Synthese von graphitischem Karbonitrid (g-C3N4); einer Spezies, welche auf Schichten hexagonal angeordneter s-Heptazineinheiten beruht, die durch kovalente Bindungen zwischen C- und N-Atomen zusammengehalten werden, und welche in einer graphitischen, verschobenen Art und Weise gestapelt sind. Der zweite Abschnitt berührt die Vielfalt von Salzschmelzensystemen, die für die Ionothermalsynthese geeignet sind und zeigt auf, dass die bloße Veränderung der Salzschmelze eine andere Kristallphase des graphitischen Karbonitrides ergibt – das g-C3N4-mod2. Im dritten Abschnitt wird vom Graphit bekannte Interkallationschemie auf das g-C3N4 angewendet, um eine Kalliuminterkallationsverbindung des graphitischen Karbonitirdes zu erhalten (K(C6N8)3). Diese Verbindung kann in Analogie zum graphitischen System leicht exfoliiert werden, um Bündel von Karbonitridnanoschichten zu erhalten, und weist darüberhinaus interessante optische Eigenschaften auf. Der vierte und letzte Abschnitt handelt von der Einführung von Aryl- und Biphenylbrücken in das Karbonitridmaterial durch rationale Synthese der Präkursormoleküle. Diese ergeben die heptazinbasierten Frameworks, HBF-1 und HBF-2 – zwei kovalente, organische Gerüste.
APA, Harvard, Vancouver, ISO, and other styles
46

Poll, Ludger Wilhelm. "Computertomographie des Herzens experimentelle und klinische Studien zur Wertigkeit der hochauflösenden schnellen EKG-synchronisierten Mehrschicht-Spiral-Computertomographie (MSCT) in der nicht-invasiven Darstellung atherosklerotischer Wandverändungen der Koronargefässe /." [S.l.] : [s.n.], 2003. http://deposit.ddb.de/cgi-bin/dokserv?idn=970646437.

Full text
APA, Harvard, Vancouver, ISO, and other styles
47

Kruse, Sebastian Heinz Herbert [Verfasser], Markus [Akademischer Betreuer] Zabel, Christian O. [Gutachter] Ritter, and Thomas [Gutachter] Paul. "Diagnostischer Stellenwert der Koronarangiographie mittels Mehrschicht- Computertomographie bei Patienten mit symptomatischem Vorhofflimmern vor Pulmonalvenenablation / Sebastian Heinz Herbert Kruse ; Gutachter: Christian O. Ritter, Thomas Paul ; Betreuer: Markus Zabel." Göttingen : Niedersächsische Staats- und Universitätsbibliothek Göttingen, 2017. http://d-nb.info/1133361420/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
48

Henke, M., and G. Gerlach. "A multi-layered variable stiffness device based on smart form closure actuators." Sage, 2016. https://tud.qucosa.de/id/qucosa%3A35622.

Full text
Abstract:
This contribution describes the properties and limitations of multi-layered mechanical devices with variable flexural stiffness. Such structures are supposed to be components of new smart, self-sensing and self-controlling composite materials for lightweight constructions. To enable a proper stiffness control, reliable actuators with high actuation capabilities based on smart materials are used. Those actuators are either driven by electroactive polymers (EAPs) or shape memory alloy (SMA) wires. They control the area moment of inertia of the multi-layered bending structures. To change the area moment of inertia and, hence, the flexural stiffness of an multi-layered beam within a wide range, it is necessary to stack as many layers as possible over each other. The fundamental function of this approach is demonstrated with a three-layer stack consisting of three independent layers and four form closure actuators driven by SMAs. This experimental set-up was able to change its bending stiffness k by a factor of 14.6, with a minimum and maximum stiffness of kmin = 0.11 N mm¯¹ and kmax = 1.73 N mm¯¹, respectively. The usage of four independently controllable actuators yields nine independent flexural-stiffness states of the beam. Both analytical and numerical calculations have shown good agreement with the measured stiffness values.
APA, Harvard, Vancouver, ISO, and other styles
49

Reggiani, Nicola. "The corpus of Greek medical papyri and digital papyrology." Universitätsbibliothek Leipzig, 2016. http://nbn-resolving.de/urn:nbn:de:bsz:15-qucosa-201726.

Full text
Abstract:
The ongoing project of digitising a corpus of ancient Greek texts on papyrus dealing with medical topics raises some problematic questions involving general issues of digital papyrology. The main electronic resource of papyrological texts, the Papyrological Navigator (papyri.info), has indeed been designed to host documentary items, while the special technical, even literary nature of medical papyri (which include, besides documents related to medicine, also handbooks, school books, and treatises by both known and unknown authors) requires new ways to treat the relevant data (paratextual devices such as diacriticals, punctuation, abbreviatios, layout features). Such issues are currently under discussion by the team charged of the forthcoming Digital Corpus of Literary Papyri (DCLP), but further options need to be taken into consideration in order to develop a fully functional, interactive, dynamic database of ancient technical texts: in particular, this paper will present and discuss the potentialities of a multi-layer linguistic annotation (useful to fulfil the needs of a multifaceted technical language) and of a multitextual digital edition (helpful in consideration of the fragmentary condition of the texts and of their often problematic relationship with the known manuscript tradition).
APA, Harvard, Vancouver, ISO, and other styles
50

Bügner, Jörg. "Nichtlineare Methoden in der trainingswissenschaftlichen Diagnostik : mit Untersuchungen aus dem Schwimmsport." Phd thesis, Universität Potsdam, 2005. http://opus.kobv.de/ubp/volltexte/2005/550/.

Full text
Abstract:

Die trainingswissenschaftliche Diagnostik in den Kernbereichen Training, Wettkampf und Leistungsfähigkeit ist durch einen hohen Praxisbezug, eine ausgeprägte strukturelle Komplexität und vielseitige Wechselwirkungen der sportwissenschaftlichen Teilgebiete geprägt. Diese Eigenschaften haben in der Vergangenheit dazu geführt, dass zentrale Fragestellungen, wie beispielsweise die Maximierung der sportlichen Leistungsfähigkeit, eine ökonomische Trainingsgestaltung, eine effektive Talentauswahl und -sichtung oder die Modellbildung noch nicht vollständig gelöst werden konnten. Neben den bereits vorhandenen linearen Lösungsansätzen werden in dieser Arbeit Methoden aus dem Bereich der Neuronalen Netzwerke eingesetzt. Diese nichtlinearen Diagnoseverfahren sind besonders geeignet für die Analyse von Prozessabläufen, wie sie beispielsweise im Training vorliegen.

Im theoretischen Teil werden zunächst Gemeinsamkeiten, Abhängigkeiten und Unterschiede in den Bereichen Training, Wettkampf und Leistungsfähigkeit untersucht sowie die Brücke zwischen trainingswissenschaftlicher Diagnostik und nichtlinearen Verfahren über die Begriffe der Interdisziplinarität und Integrativität geschlagen. Angelehnt an die Theorie der Neuronalen Netze werden anschließend die Grundlagenmodelle Perzeptron, Multilayer-Perzeptron und Selbstorganisierende Karten theoretisch erläutert. Im empirischen Teil stehen dann die nichtlineare Analyse von personalen Anforderungsstrukturen, Zustände der sportlichen Form und die Prognose sportlichen Talents - allesamt bei jugendlichen Leistungsschwimmerinnen und -schwimmern - im Mittelpunkt. Die nichtlinearen Methoden werden dabei einerseits auf ihre wissenschaftliche Aussagekraft überprüft, andererseits untereinander sowie mit linearen Verfahren verglichen.


The diagnostic methods in training science concentrate on the core areas of training, competition, and performance. The methods commonly used are characterized by a high degree of practical applicability and distinct structural complexity. These characteristics have led to the question which scientific methods fit best for resolving problems like, for example, the optimization of athletic performance, efficient planning and monitoring of training processes, effective talent screening, selection and development, or the formation of analytical models. All these questions have not yet been answered sufficiently.

Aside from the traditional mathematical approaches on the basis of the linear model, nonlinear methods in the field of neural networks are used in this dissertation. These nonlinear diagnostic methods are especially suitable for the analysis of coherent patterns in time series such as training processes.

In the theoretical part of the dissertation, common aspects, mutual dependencies, and differences between training, competition, and performance are examined. In this context, a bridge is built between the diagnostic purposes in these fields and suitable nonlinear methods. Along the lines of the neural networks theory, the basic models Perceptron, Multilayer-Perceptron, and Self-Organizing Feature Maps are subsequently elucidated.

In the empirical part of the thesis, three studies conducted with top level adolescent swimmers are presented that focus on the nonlinear analysis of personal athletic ability structures, different states of athletic shape, and the prognosis of athletic talent. The nonlinear methods are thus examined as to how worthwhile they are for analytical purposes in training science on the one hand, and they are compared to each other as well as to linear methods on the other hand.

APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography