Academic literature on the topic 'Metodo oscillometrico'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Metodo oscillometrico.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Metodo oscillometrico"

1

UGHI, FUAD, and GREGORIUS ALVIN DEWANTO. "Karakteristik Osilometrik dari Simulator Tekanan Darah." ELKOMIKA: Jurnal Teknik Energi Elektrik, Teknik Telekomunikasi, & Teknik Elektronika 5, no. 1 (2018): 15. http://dx.doi.org/10.26760/elkomika.v5i1.15.

Full text
Abstract:
ABSTRAKDalam proses evaluasi performa tensimeter otomatis, simulator tekanan darah biasa digunakan sebagai nilai referensi. Simulator akan memberikan osilasi tekanan yang merepresentasikan detak jantung pada manset tensimeter untuk menyimulasikan tekanan darah sesuai metode osilometrik. Studi ini merupakan bagian dari pengembangan simulator tekanan darah. Studi ini bertujuan untuk menganalisis karakteristik osilometrik dari sebuah simulator tekanan darah komersial, untuk kemudian digunakan sebagai data referensi untuk pengembangan simulator tekanan darah. Data osilometrik diambil dari simulato
APA, Harvard, Vancouver, ISO, and other styles
2

Susana, Ernia. "Pengukuran Tekanan Darah Non-Invasive Tanpa Manset Menggunakan Metode Pulse Transit Time Berbasis Machine Learning Multivariat Regresi." Jurnal Kesehatan 10, no. 1 (2019): 61. http://dx.doi.org/10.26630/jk.v10i1.1085.

Full text
Abstract:
<p>Currently used non-invasive blood pressure (NIBP) measurements (oscillometric method) has disadvantages related to pumping cuffs which can cause discomfort for patients due to pressure from pumping cuffs. The aim of this study was to measure blood pressure in a non-invasive manner without cuffs with the Pulse Transit Time (PTT) methodbase on machine learning technology.The blood pressure measurement by the PTT method is obtained from the calculation of the distance of the R-ECG wave with the peak signal <em>photoplethysmogram</em><em> </em>(PPG). The main probl
APA, Harvard, Vancouver, ISO, and other styles
3

Kunz Sebba Barroso, Weimar, Claudia Ferreira Gonçalves, João Alexandre Costa Berigó, et al. "Tonometric and Oscillometric Methods for Measurement of Central Blood Pressure Parameters: a Comparison in Patients with Borderline Hypertension or Stage 1 Hypertension." International Journal of Cardiovascular Sciences, 2020. http://dx.doi.org/10.36660/ijcs.20190020.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Dissertations / Theses on the topic "Metodo oscillometrico"

1

Bozzi, Cionci Arianna. "Metodi di analisi e monitoraggio della pressione arteriosa." Bachelor's thesis, Alma Mater Studiorum - Università di Bologna, 2019.

Find full text
Abstract:
La misurazione della pressione arteriosa è molto comune nella pratica clinica poichè permette di avere una valutazione generale sullo stato di salute del paziente. La pressione arteriosa viene rilevata sia nei controlli di routine che nell'assistenza di un paziente in area critica. La misurazione può essere non invasiva oppure invasiva. La tecnica invasiva consiste nella rilevazione della pressione arteriosa tramite catetere. Il monitoraggio può avvenire tramite sensore extravascolare oppure intravascolare. I metodi non invasivi invece, permettono di valutare in maniera indiretta e ad in
APA, Harvard, Vancouver, ISO, and other styles
2

Olsson, Jenny. "Reproducerbarhetsstudie av 24 timmars blodtrycksregistrering." Thesis, Örebro University, Örebro University, Örebro University, 2009. http://urn.kb.se/resolve?urn=urn:nbn:se:oru:diva-7099.

Full text
Abstract:
<p>Det finns tillfällen då kliniskt uppmätta blodtryck inte återger patientens allmänna blodtryckssituation och kardiovaskulära belastning, vid dessa tillfällen är det möjligt att låta patienten genomgå noninvasiv blodtrycksmätning under till exempel ett dygn. Reproducerbarheten för denna metod har visat sig vara överlägsen blodtrycksmätningen som utförs på klinik. Syftet med denna studie var att undersöka metodens reproducerbarhet genom att se om det fanns någon systematisk skillnad i resultatet första gången undersökningen jämförs med andra gången, samt om det fanns någon systematisk skillna
APA, Harvard, Vancouver, ISO, and other styles
3

Talts, Jaak. "Continuous non-invasive blood pressure measurement: comparative and methodological studies of the differential servo-oscillometric method /." Online version, 2004. http://dspace.utlib.ee/dspace/bitstream/10062/932/5/Talts.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Dageville, Christian. "Mesure de la pression arterielle par methode oscillometrique chez le nouveau-ne a terme, en bonne sante, pendant les premieres heures de vie." Nice, 1992. http://www.theses.fr/1992NICE6581.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Koohi, Iraj. "Methods for Non-invasive Trustworthy Estimation of Arterial Blood Pressure." Thesis, Université d'Ottawa / University of Ottawa, 2017. http://hdl.handle.net/10393/35830.

Full text
Abstract:
The trustworthiness of the blood pressure (BP) readings acquired by oscillometric home-based monitoring systems is a challenging issue that requires patients to see the doctor for trusted measurements, especially those who are obese or have cardiovascular diseases such as hypertension or atrial fibrillation. Even with the most accurate monitors one may get different readings if BP is repeatedly measured. Trusted BP readings are those measured with accurate devices at proper measurement conditions. The accurate monitors need an indicator to assure the trustworthiness of the measured BP. In this
APA, Harvard, Vancouver, ISO, and other styles
6

Arvela, Sofia Coelho. "Medição da pressão arterial em canídeos e felinos." Master's thesis, Universidade Técnica de Lisboa. Faculdade de Medicina Veterinária, 2013. http://hdl.handle.net/10400.5/5978.

Full text
Abstract:
Dissertação de Mestrado Integrado em Medicina Veterinária<br>Neste trabalho realizou-se um estudo sobre as metodologias disponíveis para avaliação da pressão arterial em canídeos e em felinos, focando aquelas metodologias exequíveis na prática clínica de forma a obter a pressão arterial de animais conscientes de uma forma rápida e prática. Realizaram-se 87 medições de pressão arterial em canídeos e felinos, incluindo animais doentes e saudáveis utilizando um aparelho oscilométrico: “PetMAP”. Os valores de pressão arterial sistólica, média e diastólica alcançados para animais saudáveis da esp
APA, Harvard, Vancouver, ISO, and other styles
7

Průdek, Ctirad. "Měřič krevního tlaku." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2010. http://www.nusl.cz/ntk/nusl-218647.

Full text
Abstract:
In my master's tehsis I'm dealin with the methods used for non-invasive blood pressure measurement. For realization of a virtual blood pressure meter in LabVEW I have chosen the oscillometric method. Algorithm determining systolic and diastolic blood pressure is based on the relatively easy detection of maximum amplitude oscillations (corresponds with a mean arterial pressure), when thelimiting valuesof blood pressure are in a specific ratio with a maximum amplitude of oscillation. In LabVIEW was solved loading of signal from the measure card and processing pressure curve into a form suitable
APA, Harvard, Vancouver, ISO, and other styles

Book chapters on the topic "Metodo oscillometrico"

1

Talts, J., R. Raamat, K. Jagomägi, and J. Kivastik. "Accuracy of the Oscillometric Fixed-Ratio Blood Pressure Measurement Using Different Methods of Characterization of Oscillometric Pulses." In IFMBE Proceedings. Springer International Publishing, 2014. http://dx.doi.org/10.1007/978-3-319-00846-2_237.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Wang, Feng, and Qiaoqiao Xu. "Suppression of respiratory interference in oscillometric waveform using wavelet ridge method." In IFMBE Proceedings. Springer Berlin Heidelberg, 2013. http://dx.doi.org/10.1007/978-3-642-29305-4_103.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Schulte, K. L., and W. Meyer-Sabellek. "Plethysmographic (volume-oscillometric) method of non-invasive monitoring ambulatory blood pressure." In Blood Pressure Measurements. Steinkopff, 1990. http://dx.doi.org/10.1007/978-3-642-72423-7_4.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Talts, J., R. Raamat, K. Jagomägi, and J. Kivastik. "The Differential Oscillometric Method Can Be Used for Recording Beat-to-Beat Arterial Pressure Patterns from Radial Arteries." In IFMBE Proceedings. Springer Berlin Heidelberg, 2013. http://dx.doi.org/10.1007/978-3-642-34197-7_11.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Thomas, Gregory S., and Myrvin H. Ellestad. "Blood Pressure Measurements during Exercise Testing." In Ellestad's Stress Testing, edited by Gregory S. Thomas, L. Samuel Wann, and Myrvin H. Ellestad. Oxford University Press, 2018. http://dx.doi.org/10.1093/med/9780190225483.003.0006.

Full text
Abstract:
``The chapter Blood Pressure Measurement During Exercise reviews the 3 methods of sphygmomanometry to measure blood pressure and normal and abnormal blood pressure responses to exercise. Mercury, aneroid, and oscillometric assessment of Korotkoff sounds provide accurate measurement. Periodic calibration is important for aneroid and oscillometric devices. With verification, automated oscillometric measurements during exercise can be accurate. The normal blood pressure response to exercise testing is an incremental increase in systolic blood pressure with minimal change in diastolic blood pressure. Exercise induced hypotension, particularly early in exercise, is predictive of severe coronary artery disease (CAD). Its occurrence at peak exercise at a high level of exertion may occur in normal individuals secondary to exhaustion. An exaggerated systolic response to exercise is modestly predictive of future hypertension. A slow decrease is systolic blood pressure during recovery is suggestive of CAD, likely secondary to less vagal tone, analogous to a slow decrease in heart rate during recovery.
APA, Harvard, Vancouver, ISO, and other styles
6

Sahin, Mesut, Howard Fidel, and Raquel Perez-Castillejos. "Oscillometric Method for Measurement of Blood Pressure." In Instrumentation Handbook for Biomedical Engineers. CRC Press, 2020. http://dx.doi.org/10.1201/9780429193989-6.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Sadykova, Dinara, Liliia Galimova, Evgeniia Slastnikova, Zulfiia Khabibrakhmanova, and Natalya Guseva. "Arterial Stiffness Assessment in Children with Familial Hypercholesterolemia." In Management of Dyslipidemia. IntechOpen, 2021. http://dx.doi.org/10.5772/intechopen.96018.

Full text
Abstract:
Familial hypercholesterolemia (FH) is the genetic disease which characterized by an increase of level total cholesterol and low density lipoproteins since childhood. The aim of the study was to assess arterial stiffness in children with heterozygous FH by measuring the pulse wave velocity (PWV) in the aorta. The study involved 118 children, 60 healthy children in the control group and 58 children with heterozygous FH in the main group. Both groups were divided into 3 age subgroups: 5–7 years old, 8–12 years old and 13–17 years old. The diagnosis of FH was made using British criteria by Simon Broome. The lipid profile was determined for all children, blood pressure was monitored daily with an estimate of the minimum, mean and maximum PWV (PWVmin, mean PWV, PWVmax) in aorta using oscillometric method. Correlation analysis in patients with FH revealed direct correlation between PWVmin, mean PWV and PWVmax with total cholesterol (r = 0.46, r = 0.46 and r = 0.464, respectively, p &lt; 0.001). The study demonstrates an increase in the PWV in the aorta in children with FH compared with healthy peers from 8–12 years of age and a progression of arterial stiffness most significant in the group of 13–17 years.
APA, Harvard, Vancouver, ISO, and other styles
8

Bianchi, Cristina, and Paul Higgs. "Comparison of the traditional human Auscultatory method versus Doppler and Oscillometric techniques for indirect blood pressure measurement: a pilot study in anaesthetised dogs." In BSAVA Congress Proceedings 2018. British Small Animal Veterinary Association, 2018. http://dx.doi.org/10.22233/9781910443590.66.1.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Conference papers on the topic "Metodo oscillometrico"

1

Lan, H., and A. M. Al-Jumaily. "New Blood Pressure Measurement Method Using Waveform Features." In ASME 2012 International Mechanical Engineering Congress and Exposition. American Society of Mechanical Engineers, 2012. http://dx.doi.org/10.1115/imece2012-87063.

Full text
Abstract:
The Ausculatory and the Oscillometric are the most commonly used blood pressure measurement methods worldwide. However, the ausculatory method requires professionally trained observers and is not suitable for automatic BP measurement; while the oscillometric method is less accurate in wide age groups. A new BP measurement method is introduced here which determines the subject’s BP value by features of the waveform measured by a strain sensor on the arm skin. During the cuff based measurement process, blood pulses in the brachial artery lead to artery deformations, which transfer to the arm sur
APA, Harvard, Vancouver, ISO, and other styles
2

Daochai, S., W. Sroykham, Y. Kajornpredanon, and C. Apaiwongse. "Non-invasive blood pressure measurement: Auscultatory method versus oscillometric method." In 2011 Biomedical Engineering International Conference (BMEiCON) - Conference postponed to 2012. IEEE, 2012. http://dx.doi.org/10.1109/bmeicon.2012.6172056.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Zheng, D., and A. Murray. "Estimation of mean blood pressure from oscillometric and manual methods." In 2008 35th Annual Computers in Cardiology Conference. IEEE, 2008. http://dx.doi.org/10.1109/cic.2008.4749198.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Koohi, Iraj, Saif Ahmad, Izmail Batkin, et al. "Method for evaluation of trustworthiness of oscillometric blood pressure measurements." In 2015 IEEE International Symposium on Medical Measurements and Applications (MeMeA). IEEE, 2015. http://dx.doi.org/10.1109/memea.2015.7145211.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Hyun-Seok Choi, Hyoun-Seok Myoung, Hyo-Ki Lee, Ho-Dong Park, and Kyoung-Joung Lee. "A new noise reduction method for oscillometric blood pressure measurement." In 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE, 2008. http://dx.doi.org/10.1109/iembs.2008.4649142.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Vallascas, Rinaldo. "A new arterial blood pressure Holter based on the oscillometric method." In 2015 IEEE International Symposium on Medical Measurements and Applications (MeMeA). IEEE, 2015. http://dx.doi.org/10.1109/memea.2015.7145203.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Liu, Chengyu, Dingchang Zheng, Clive Griffiths, and Alan Murray. "Comparison of repeatability of blood pressure measurements between oscillometric and auscultatory methods." In 2015 Computing in Cardiology Conference (CinC). IEEE, 2015. http://dx.doi.org/10.1109/cic.2015.7411100.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Huang, Ping, Jun Fu, and Yunfeng Zhao. "A Matlab demo software for NIBP measurement based on hybrid oscillometric method." In 2011 4th International Congress on Image and Signal Processing (CISP). IEEE, 2011. http://dx.doi.org/10.1109/cisp.2011.6100763.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Yu, Danyang, Mengsun Yu, Haiyan Xiang, Yuqi Wang, Yanyong Liu, and Xiuyan Yang. "A Novel Method for Korotkoff Vibration Blood Pressure Measurement Based on Oscillometric." In 2010 International Conference on Intelligent Computation Technology and Automation (ICICTA). IEEE, 2010. http://dx.doi.org/10.1109/icicta.2010.564.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Hsiao, Fu-Jung, and Chen-Chuan Hung. "Noninvasive blood pressure analysis using empirical mode decomposition (EMD) - Based oscillometric method." In 2010 3rd International Conference on Biomedical Engineering and Informatics (BMEI). IEEE, 2010. http://dx.doi.org/10.1109/bmei.2010.5639803.

Full text
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!