To see the other types of publications on this topic, follow the link: Monitoring protocol.

Journal articles on the topic 'Monitoring protocol'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 journal articles for your research on the topic 'Monitoring protocol.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse journal articles on a wide variety of disciplines and organise your bibliography correctly.

1

Zhang, Li Xin, and Liang Wang. "Industrial Monitoring Wireless Sensor Network Routing Algorithm and Simulation." Advanced Materials Research 457-458 (January 2012): 1149–54. http://dx.doi.org/10.4028/www.scientific.net/amr.457-458.1149.

Full text
Abstract:
Aiming at the routing protocol in an industrial monitoring system, this paper analyzes the demand of the industrial monitoring wireless routing protocol, proposes a region adaptive routing protocol, and provides the algorithm, procedure and data structure of the route protocol in the industrial monitoring system. Simulation results show that the result of quantitative description compared energy consumption with time delay, this protocol is superior to orientation spreading, sensor protocols for information via negotiation(SPIN) and passing more energy protocols in both aspects, this algorithm
APA, Harvard, Vancouver, ISO, and other styles
2

Ferreira Penêda, José, Nuno Barros Lima, Leandro Ribeiro, Diamantino Helena, Bruno Domingues, and Artur Condé. "Cochleotoxicity monitoring protocol." Acta Otorrinolaringológica Española 69, no. 2 (2018): 105–9. http://dx.doi.org/10.1016/j.otorri.2017.03.005.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Ferreira Penêda, José, Nuno Barros Lima, Leandro Ribeiro, Diamantino Helena, Bruno Domingues, and Artur Condé. "Cochleotoxicity monitoring protocol." Acta Otorrinolaringologica (English Edition) 69, no. 2 (2018): 105–9. http://dx.doi.org/10.1016/j.otoeng.2018.03.001.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Kirankumar, G. "Vehicle Speed Monitoring System [VSM] (Using RuBee Protocol)." International Journal of Engineering and Technology 4, no. 1 (2012): 107–10. http://dx.doi.org/10.7763/ijet.2012.v4.328.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Kruse, Astrid L., Heinz T. Luebbers, Klaus W. Grätz, and Joachim A. Obwegeser. "Free Flap Monitoring Protocol." Journal of Craniofacial Surgery 21, no. 4 (2010): 1262–63. http://dx.doi.org/10.1097/scs.0b013e3181e1e6e9.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Fakhrudin, Audi Diva, Nurul Fahmi Arief Hakim, and Agus Heri Setya Budi. "Implementasi Protokol TCP dan UDP pada Sistem Monitoring dan Otomasi Rumah Jamur Berorientasi WSN." TELKA - Telekomunikasi Elektronika Komputasi dan Kontrol 9, no. 2 (2023): 130–44. http://dx.doi.org/10.15575/telka.v9n2.130-144.

Full text
Abstract:
Sistem monitoring dan otomasi rumah jamur sangat diperlukan untuk budidaya jamur. Sistem ini membutuhkan suatu protokol yang dapat membantu pengiriman data yang handal agar keadaan lingkungan dapat terpantau dengan baik. Ketika jaringan dengan protokol TCP terganggu, monitoring kondisi kumbung jamur akan terhambat, berdampak pada pertumbuhan jamur yang tidak optimal. Penelitian ini bertujuan untuk mengimplementasikan protokol TCP dan UDP pada sistem monitoring dan otomasi rumah jamur menggunakan iot berorientasi Wireless Sensor Network (WSN). Sistem menggunakan dua jenis mirkokontroller Wemos
APA, Harvard, Vancouver, ISO, and other styles
7

Lutes, Duncan C., Nathan C. Benson, MaryBeth Keifer, John F. Caratti, and S. Austin Streetman. "FFI: a software tool for ecological monitoring." International Journal of Wildland Fire 18, no. 3 (2009): 310. http://dx.doi.org/10.1071/wf08083.

Full text
Abstract:
A new monitoring tool called FFI (FEAT/FIREMON Integrated) has been developed to assist managers with collection, storage and analysis of ecological information. The tool was developed through the complementary integration of two fire effects monitoring systems commonly used in the United States: FIREMON and the Fire Ecology Assessment Tool. FFI provides software components for: data entry, data storage, Geographic Information System, summary reports, analysis tools and Personal Digital Assistant use. In addition to a large set of standard FFI protocols, the Protocol Manager lets users define
APA, Harvard, Vancouver, ISO, and other styles
8

K., Muthumayil, and Buvana M. "A PERVASIVE APPLICATION FOR PATIENT MONITORING IN WIRELESS SENSOR NETWORKS." International Journal of Advanced Trends in Engineering and Technology 1, no. 2 (2017): 22–24. https://doi.org/10.5281/zenodo.345651.

Full text
Abstract:
A Multi path Low Overhead Ad-Hoc Routing Protocol is proposed for wireless sensor system. The protocol performs course revelation when required in an on-interest way. An optimal path is obtained using PSO – [Particle Swarm Optimization]. The execution of the proposed protocol is measured as far as system throughput, parcel conveyance proportion, normal end-to- end postpone and control overhead. The results are contrasted with those acquired utilizing comparable on-interest directing protocols.
APA, Harvard, Vancouver, ISO, and other styles
9

Said Al Manshury, Muhammad. "Penggunaan Software Wireshark untuk Monitoring dan Troubleshooting pada Komunikasi Client Server IEC 61850." ELECTRON Jurnal Ilmiah Teknik Elektro 4, no. 2 (2023): 62–69. http://dx.doi.org/10.33019/electron.v4i2.49.

Full text
Abstract:
Pengiriman data (status, pengukuran, kontrol) antara Sistem Otomasi Gardu Induk (SOGI) berbeda dengan Gardu Induk Konvensional. GI Konvensional menggunakan kabel (hardwired) untuk mengirimkan data, sedangkan pada SOGI pengiriman data menggunakan komunikasi data via jaringan ethernet yaitu dengan menggunakan protokol IEC 61850. Protokol IEC 61850 saat ini banyak digunakan untuk komunikasi di dalam Gardu Induk. Saat ini SOGI sudah banyak diterapkan di PLN, di mana protokol IEC 61850 adalah protokol mandatory yang digunakan dalam SOGI. SOGI terdiri dari berbagai macam peralatan seperti : server,
APA, Harvard, Vancouver, ISO, and other styles
10

Smelser, Jamie F., Stephen L. Gardella, and Betty L. Austin. "Protocol audits for post-approval monitoring of animal use protocols." Lab Animal 34, no. 10 (2005): 23–27. http://dx.doi.org/10.1038/laban1105-23.

Full text
APA, Harvard, Vancouver, ISO, and other styles
11

Ashok, Karthik Sagar, Basavaraj Gangasamudra Nagendrappa, Mohan Bangalore Anjaneyalu, et al. "Wireless sensor networks based efficient drip irrigation monitoring systems." International Journal of Electrical and Computer Engineering (IJECE) 15, no. 1 (2025): 677. http://dx.doi.org/10.11591/ijece.v15i1.pp677-688.

Full text
Abstract:
Cotton has profound significance in the textile industry due to its versatility, comfort and ease of care. But the main problem with conventional cotton farming is that it uses more water. These issues are made more difficult by conventional irrigation methods, such as drip irrigation. To address this problem researchers are using traditional farming techniques with advanced wireless sensor network (WSN) protocols to resolve catastrophic issues, such as pipe bursts or blocked emitters which are detected early to save the water. This paper introduces efficient WSN architecture using priority-ba
APA, Harvard, Vancouver, ISO, and other styles
12

Sari, Aisah Nur Endah. "Smart Monitoring System Room Temperature Server Based on Iot Using Http Communication Protocol Method at Xyz University." Informatics Management, Engineering and Information System Journal 3, no. 1 (2025): 66–88. https://doi.org/10.56447/imeisj.v3i1.432.

Full text
Abstract:
XYZ University, which relies on servers for administrative and academic functions, continues to employ manual temperature monitoring through physical site visits to the server locations. This method presents a risk of delayed response to temperature fluctuations, which could lead to operational issues and data loss. This project aims to establish a real-time temperature monitoring system for server rooms, utilizing IoT and employing the HTTP protocol for communication. The evaluation concentrates on assessing the latency of the HTTP protocol and the dimensions of data packets to verify the sys
APA, Harvard, Vancouver, ISO, and other styles
13

Vishnyakou, U. A., and Bahaa Shaya. "Optimization of the iot network protocol choozing for monitoring audio information." «System analysis and applied information science», no. 2 (October 4, 2023): 32–37. http://dx.doi.org/10.21122/2309-4923-2023-2-32-37.

Full text
Abstract:
The subject of research is the choice of a protocol in the Internet of Things (IoT) network for monitoring and analyzing audio information. The purpose of the article is to optimize the process of choosing a protocol for monitoring audio information based on IoT and evaluate the results. The authors have developed an IoT framework for monitoring and analyzing audio and voice information. The IoT network includes a sound sensor (microphone), a unit for analyzing the information received from it and a decision-making module. The description of protocols in the IoT network for assessing the sound
APA, Harvard, Vancouver, ISO, and other styles
14

Ullah, Niamat, M. Sanaullah Chowdhury, Mosaddique Al Ameen, and Kyung Sup Kwak. "Energy Efficient MAC Protocol for Low-Energy Critical Infrastructure Monitoring Networks Using Wakeup Radio." International Journal of Distributed Sensor Networks 8, no. 4 (2012): 504946. http://dx.doi.org/10.1155/2012/504946.

Full text
Abstract:
Critical infrastructure monitoring applications are rapidly increasing. Application requirements include reliable data transfer, energy efficiency, and long deployment lifetime. These applications must also be able to operate in an extremely low-cost communication environment in order to be attractive to potential users. A low rate wireless personal area network can help control and manage the operations of such applications. In this paper, we present a medium access control (MAC) protocol for low-energy critical infrastructure monitoring (LECIM) applications. The proposed MAC protocol is base
APA, Harvard, Vancouver, ISO, and other styles
15

Ashok, Karthik Sagar, Basavaraj Gangasamudra Nagendrappa, Mohan Bangalore Anjaneyalu, Priya Nandihal, Veena Narayana Reddy, and Liyakathunisa Syed. "Wireless sensor networks based efficient drip irrigation monitoring systems." International Journal of Electrical and Computer Engineering (IJECE) 15, no. 1 (2025): 677–88. https://doi.org/10.11591/ijece.v15i1.pp677-688.

Full text
Abstract:
Cotton has profound significance in the textile industry due to its versatility, comfort and ease of care. But the main problem with conventional cotton farming is that it uses more water. These issues are made more difficult by conventional irrigation methods, such as drip irrigation. To address this problem researchers are using traditional farming techniques with advanced wireless sensor network (WSN) protocols to resolve catastrophic issues, such as pipe bursts or blocked emitters which are detected early to save the water. This paper introduces efficient WSN architecture using priority-ba
APA, Harvard, Vancouver, ISO, and other styles
16

Singh, Kamred Udham. "Design Of Energy Efficient and Secure Routing Protocol for Wsn in Iot." Mathematical Statistician and Engineering Applications 70, no. 2 (2021): 1434–41. http://dx.doi.org/10.17762/msea.v70i2.2336.

Full text
Abstract:

 
 
 
 Abstract
 This paper proposes an energy-efficient and secure routing system for wireless sensor networks (WSNs) in the Internet of Things (IoT). The proposed routing protocol improves packet delivery ratio, end-to-end latency, and network lifetime over existing protocols. The protocol under consideration reduces node energy consumption, increasing the network's lifetime, while ensuring data security. Simulation studies using several metrics evaluate the proposed procedure. The recommended protocol outperforms existing protocols in energy efficiency and security
APA, Harvard, Vancouver, ISO, and other styles
17

Xie, Qi, Dongnan Liu, Zixuan Ding, Xiao Tan, and Lidong Han. "Provably Secure and Lightweight Patient Monitoring Protocol for Wireless Body Area Network in IoHT." Journal of Healthcare Engineering 2023 (February 13, 2023): 1–13. http://dx.doi.org/10.1155/2023/4845850.

Full text
Abstract:
As one of the important applications of Internet of Health Things (IoHT) technology in the field of healthcare, wireless body area network (WBAN) has been widely used in medical therapy, and it can not only monitor and record physiological information but also transmit the data collected by sensor devices to the server in time. However, due to the unreliability and vulnerability of wireless network communication, as well as the limited storage and computing resources of sensor nodes in WBAN, a lot of authentication protocols for WBAN have been devised. In 2021, Alzahrani et al. designed an ano
APA, Harvard, Vancouver, ISO, and other styles
18

Fan, Dong, Yin Sheng Weng, and Hong Liang Tian. "Study on Monitoring and Control System of Vehicle-Mounted Rig Based on CAN Bus." Applied Mechanics and Materials 397-400 (September 2013): 1655–60. http://dx.doi.org/10.4028/www.scientific.net/amm.397-400.1655.

Full text
Abstract:
The monitoring and control system based on CAN bus was designed in order to implement the data reliable transmission between all nodes in the control system of the vehicle-mounted rig. Firstly, the hardware structure of the monitoring system was designed in the paper, and two CAN network was built, which one CAN network used CANopen protocol and the other used J1939 protocol and CAN2.0B protocol, that it saved the resource of hardware and software. Secondly, all CAN protocols , program flow chart and software with Labview were designed in detail. The application results of the actual engineeri
APA, Harvard, Vancouver, ISO, and other styles
19

Pasha, Muhammad Adeel, Jahangir Hassan Khan, and Shahid Masud. "I-LEACH: energy-efficient routing protocol for monitoring of irrigation canals." SIMULATION 91, no. 8 (2015): 750–64. http://dx.doi.org/10.1177/0037549715602957.

Full text
Abstract:
Irrigation canals and their tributaries, originating from the run of a river, span a considerable geographical area that is typically of the order of 100 km2. Efficient deployment of wireless sensor networks (WSNs) to monitor and control the flow of scarce water resources is a challenging task, mainly because the WSN motes are designed to consume very low power and communicate over very short distances. This paper investigates the use of different WSN protocols to monitor water usage over irrigation networks in the province of Punjab, Pakistan. This irrigation network is considered to be among
APA, Harvard, Vancouver, ISO, and other styles
20

Zhao, Yifan, Shengjie Zhou, Hongwei Ding, Shaowen Yao, Zhijun Yang, and Qianlin Liu. "CSMA/CA MAC Protocol with Function of Monitoring based on Binary Tree Conflict Resolution for Cognitive Radio Networks." International Journal of Software Science and Computational Intelligence 8, no. 2 (2016): 35–51. http://dx.doi.org/10.4018/ijssci.2016040103.

Full text
Abstract:
The CSMA/CA protocol is the most widely-compete agreement used by a network. Therefore, MAC layer of cognitive radio networks mostly use the CSMA/CA protocol to provide the competitive channel resources. Due to the unique characteristics and related needs of the cognitive radio networks, design their network protocol is a critical task. For its characteristics, design and implement a comprehensive CSMA/CA protocol, including arrival rate control, priority services, monitoring, conflict resolution and increased throughput; elaborated protocol model, system throughput and other parameters, demon
APA, Harvard, Vancouver, ISO, and other styles
21

Abul, Hassan Muhammad, Syed Irfan Ullah, Abdus Salam, Arbab Wajid Ullah, Muhammad Imad, and Farhat Ullah. "Energy efficient hierarchical based fish eye state routing protocol for flying Ad-hoc networks." Indonesian Journal of Electrical Engineering and Computer Science 21, no. 1 (2021): 465–71. https://doi.org/10.11591/ijeecs.v21.i1.pp465-471.

Full text
Abstract:
Flying Ad-hoc networks are emergent area in Ad-hoc networks evolved from MANETs and VANETs. Small unmanned aerial vehicles (UAVs) are used in FANETs applications and these small UAVs have limited resources while efficiently utilization of these resources is most critical task in real time monitoring of FANETs application. Network consumes its resources in path selection process and data routing from source to destination. Selecting of efficient routing protocol to utilize all available resources played vital role in extending network life time. In this article fisheye state routing (FSR) proto
APA, Harvard, Vancouver, ISO, and other styles
22

Hakim, Ahmad Tsaqib, Arrum Prima Dewi, Doan Perdana, and Cyril Nugrahutama Kurnaman. "Energy Consumption Analysis of DBR and VBF Protocols in Underwater Sensor Networks Using Aqua-Sim at Network Simulator 2." JURNAL INFOTEL 10, no. 4 (2018): 170. http://dx.doi.org/10.20895/infotel.v10i4.394.

Full text
Abstract:
For decades, there have been significant interests in monitoring the aquatic environment for scientific exploration, commercial exploitation, coastline protection, and even disasters prevention and mitigation such as tsunami warnings. Highly precise, real-time, and temporal-spatial continuous aquatic environment monitoring system is extremely important for underwater life. To support and simulate such monitoring system, underwater sensor networks (UWSN) have emerged as a very powerful technique for many applications on underwater environment, including monitoring, measurement, surveillance, an
APA, Harvard, Vancouver, ISO, and other styles
23

Yang, Xiao Jing, and Sheng Li Chen. "Study on a Wireless Temperature and Humidity Monitoring System for Workshop with Constant Temperature Based on SCM." Applied Mechanics and Materials 701-702 (December 2014): 593–97. http://dx.doi.org/10.4028/www.scientific.net/amm.701-702.593.

Full text
Abstract:
A wireless temperature and humidity monitoring system for workshop with constant temperature based on AT89C52 Single chip microcomputer and nRF905 wireless microchip is studied. The system is consists of base station and slave station. Base station is mainly consists of temperature acquisition module, humidity acquisition module, wireless communicating module and communicating testing module. Good communication protocols play an important role in ensuring the correct monitoring data. So the network topology, communication data form, ad hoc networks protocol, mac protocol and data link layer pr
APA, Harvard, Vancouver, ISO, and other styles
24

Soteropulos, Carol, Jenny Chen, Samuel Poore, and Catharine Garland. "Postoperative Management of Lower Extremity Free Tissue Transfer: A Systematic Review." Journal of Reconstructive Microsurgery 35, no. 01 (2018): 001–7. http://dx.doi.org/10.1055/s-0038-1667049.

Full text
Abstract:
Background Free tissue transfer for lower extremity reconstruction is a safe and reliable option for a wide range of challenging wounds; however, no consensus exists regarding postoperative management. Methods A systematic review of postoperative management of lower extremity free tissue transfer was conducted using Medline, Cochrane Database, and Web of Science. Multicenter surveys, randomized controlled trials, cohort studies, and case series were reviewed. Results Fifteen articles investigating current protocols, flap physiology, and aggressive dangle protocols were reviewed. The following
APA, Harvard, Vancouver, ISO, and other styles
25

Ma, Xiaoping, Honghui Dong, Junqing Tang, Limin Jia, Yong Qin, and Ruijun Cheng. "Two-Layer Hierarchy Optimization Model for Communication Protocol in Railway Wireless Monitoring Networks." Wireless Communications and Mobile Computing 2018 (2018): 1–14. http://dx.doi.org/10.1155/2018/9516342.

Full text
Abstract:
The wireless monitoring system is always destroyed by the insufficient energy of the sensors in railway. Hence, how to optimize the communication protocol and extend the system lifetime is crucial to ensure the stability of system. However, the existing studies focused primarily on cluster-based or multihop protocols individually, which are ineffective in coping with the complex communication scenarios in the railway wireless monitoring system (RWMS). This study proposes a hybrid protocol which combines the cluster-based and multihop protocols (CMCP) to minimize and balance the energy consumpt
APA, Harvard, Vancouver, ISO, and other styles
26

Viani, Ricardo A. G., Karen D. Holl, Aurelio Padovezi, et al. "Protocol for Monitoring Tropical Forest Restoration." Tropical Conservation Science 10 (January 2017): 194008291769726. http://dx.doi.org/10.1177/1940082917697265.

Full text
APA, Harvard, Vancouver, ISO, and other styles
27

Ly, John. "INR Monitoring Protocol for Warfarin Therapy." Canadian Pharmacists Journal / Revue des Pharmaciens du Canada 138, no. 6 (2005): 43–44. http://dx.doi.org/10.1177/171516350513800609.

Full text
APA, Harvard, Vancouver, ISO, and other styles
28

Liu, Ye Hui. "Design of Multi-Protocol Converter under Coal Mine Based S3C2440." Applied Mechanics and Materials 539 (July 2014): 563–66. http://dx.doi.org/10.4028/www.scientific.net/amm.539.563.

Full text
Abstract:
In recent years, China's coal industry accidents occur frequently, seriously affect the development of the coal industry, for the job site in the coal mine monitoring system installed several monitoring of coal mine production equipment to ensure safety and reliable operation of equipment. However, a plurality of building monitoring system meets some problems, such as reducing the waste of resources and production costs, and improve the level of safety management, the use of embedded technology designed S3c2440 based multi-protocol converter, prompting the original coal use different protocols
APA, Harvard, Vancouver, ISO, and other styles
29

Lin, Zhidong, Yanmin Fu, and Xuefeng Deng. "Safety Training Monitoring System of Ski Resort Based on Wireless Sensor Network." Wireless Communications and Mobile Computing 2022 (February 17, 2022): 1–12. http://dx.doi.org/10.1155/2022/6355567.

Full text
Abstract:
With the gradual rise in China’s ski industry, skiing is now the most common sport among winter outdoor sports, which is closely related to the origin of safety issues. Based on the ski resort, training is the key to safety detection, only to ensure the safety of training personnel and to maintain the momentum of high-speed development of skiing sports for a long time. The monitoring system plays an important role in the wireless sensor network monitoring system. Common monitoring systems are used for agriculture, smart home, and outdoor environment monitoring systems, most of which are profes
APA, Harvard, Vancouver, ISO, and other styles
30

Alnawafa, Emad, and Mohammad Allaymoun. "EDMR: An Enhanced Dynamic Multi-Hop Routing Protocol with a Novel Sleeping Mechanism for Wireless Sensor Networks." Sensors 25, no. 14 (2025): 4510. https://doi.org/10.3390/s25144510.

Full text
Abstract:
Numerous protocols have emerged to address the energy depletion problem in Wireless Sensor Networks (WSNs). Among these protocols, the Dynamic Multi-Hop Routing (DMR) protocol adopts a dynamic technique for routing data across the network. The use of the DMR protocol has shown promising results in reducing energy consumption, prolonging the network lifetime, and increasing throughput. To improve the performance of WSNs, this paper proposes the Enhanced Dynamic Multi-Hop Routing (EDMR) protocol as a modification of the DMR protocol. The EDMR protocol introduces an effective sleeping mechanism t
APA, Harvard, Vancouver, ISO, and other styles
31

Surono, Surono, and Mohammad Burhan Hanif. "Penerapan Protokol Simple Network Management Protocol Monitoring LIBRE NMS Pada Jaringan Internet." Joined Journal (Journal of Informatics Education) 7, no. 2 (2024): 272. https://doi.org/10.31331/joined.v7i2.3634.

Full text
Abstract:
Simple Network Management Protocol adalah protokol yang digunakan untuk mengelola dan memantau perangkat jaringan. Dalam implementasi pada sistem monitoring Libre NMS pada jaringan internet, protokol ini digunakan untuk memantau kinerja jaringan dan memastikan bahwa jaringan berfungsi dengan baik. Libre NMS adalah perangkat lunak sumber terbuka yang digunakan untuk monitoring jaringan dan menyediakan antarmuka yang intuitif untuk mengelola dan memantau perangkat jaringan. Dengan menggunakan SNMP, Libre NMS dapat mengumpulkan data dari perangkat jaringan seperti switch, router, dan server dan m
APA, Harvard, Vancouver, ISO, and other styles
32

Mutalemwa, Lilian. "On the Use of Wireless Technologies for Wildlife Monitoring: Wireless Sensor Network Routing Protocols." Tanzania Journal of Engineering and Technology 42, no. 2 (2023): 113–33. http://dx.doi.org/10.52339/tjet.v42i2.837.

Full text
Abstract:
Traditional methods for wildlife monitoring are labor-intensive and time-consuming. Therefore, advanced technologies and remote monitoring methods are becoming increasingly popular. This paper presents a study on wireless technologies for wildlife monitoring. In the study, a review of the literature was done to identify the most commonly used wireless technologies. Various technologies were explored including unmanned aerial vehicles (UAVs), Internet of Things (IoT), wireless sensor networks (WSNs), artificial intelligence (AI), global positioning system (GPS), and very high frequency (VHF) ra
APA, Harvard, Vancouver, ISO, and other styles
33

Pratama, Redo, Mira Orisa, and FX Ariwibisono. "APLIKASI MONITORING DAN CONTROLLING SERVER MENGGUNAKAN PROTOCOL ICMP (INTERNET CONTROL MESSAGE PROTOCOL) DAN SSH (SECURE SHELL) BERBASIS WEBSITE." JATI (Jurnal Mahasiswa Teknik Informatika) 4, no. 1 (2020): 397–403. http://dx.doi.org/10.36040/jati.v4i1.2310.

Full text
Abstract:
Sistem monitoring server sangat dibutuhkan bagi seorang administrator. Sebab memastika setiap server dalam kondisi yang baik merupakan tugas utama dari administrator, karena sifat server yang harus dalam kondisi online atau hidup setiap Sistem monitoring yang saat ini digunakan ialah dengan cara mengecek setiap server yang dikelolanya. Dengan cara tersebut maka administrator dapat mengetahui kondisi fisik serta keadaan server dalam keadaan up atau down.
 Dengan menggunakan protocoi ICMP (Internet Control Message Protocol) untuk menjalankan fitur monitoring server secara real time, serta m
APA, Harvard, Vancouver, ISO, and other styles
34

Hasan, Ammar, Tarik A. Rashid, Birzo Ismael, and Nawzad K. AL-Salihi. "Transmission Control Protocol Performance Monitoring for Simulated Wired University Computer Network using OPNET." UKH Journal of Science and Engineering 3, no. 1 (2019): 18–28. http://dx.doi.org/10.25079/ukhjse.v3n1y2019.pp18-28.

Full text
Abstract:
Computer networks need protocols to govern all transmission and presentation processes. The transmission control protocol (TCP) is one of the most important protocols that have the compatibility to work with all types of computer networks, overcoming all architectural and operating system differences. Nowadays, networks depend on the TCP protocol to control data flow between all types of connected computers, whether it is client or server, over any type of media whether it is wired or wireless networks, for all network topologies. A simulation of a university campus network has been conducted
APA, Harvard, Vancouver, ISO, and other styles
35

Naveda-Rodríguez, Adrián, Víctor Utreras B., and Galo Zapata-Ríos. "A standardised monitoring protocol for the black caiman (Melanosuchus niger)." Wildlife Research 47, no. 4 (2020): 317. http://dx.doi.org/10.1071/wr19135.

Full text
Abstract:
Abstract ContextEstimating population abundance can be plagued by the violation of methodological assumptions, which can be overcome with standardised protocols. The black caiman (BC) is considered a conservation-dependent species, and previous abundance estimates are surrounded by uncertainty and flaws in the survey (e.g. different survey design and efforts) and analytical approach used (e.g. relative abundance index, which ignores imperfect detection). Its conservation status assessment demands the implementation of a standardised monitoring protocol. AimsThe protocol provides guidelines to
APA, Harvard, Vancouver, ISO, and other styles
36

Renganathan, BS, Sridhar Nagaiyan, SP Preejith, Shameer Gopal, Susovan Mitra, and Mohanasankar Sivaprakasam. "Effectiveness of a continuous patient position monitoring system in improving hospital turn protocol compliance in an ICU: A multiphase multisite study in India." Journal of the Intensive Care Society 20, no. 4 (2018): 309–15. http://dx.doi.org/10.1177/1751143718804682.

Full text
Abstract:
Purpose Hospital-acquired pressure ulcers are a significant cause of morbidity and consume considerable financial resources. Turn protocols (repositioning patients at regular intervals) are utilized to reduce incidence of pressure ulcers. Adherence to turn protocols is particularly challenging for nursing teams, given the high number of interventions in intensive care unit, and lack of widely available tools to monitor patient position and generate alerts. We decided to develop and evaluate usefulness of a continuous patient position monitoring system to assist nurses in improving turn protoco
APA, Harvard, Vancouver, ISO, and other styles
37

Hussain, Kashif. "Comparative Analysis of DNA Extraction Protocols from Blood for Bovine Theileriosis." International Journal of Agriculture and Biology 34, no. 03 (2025): 340301. https://doi.org/10.17957/ijab/15.2361.

Full text
Abstract:
Genomic DNA serves as the foundation for molecular research and advancements including disease sureveillance, biodiversity conservation and environmental monitoring etc. Cost-effectiveness coupled with DNA quality and quantity are prerequisites for molecular tools, which depend on extraction protocols. The current study compared four DNA extraction protocols to evaluate DNA quantity, integrity, purity, cost-effectiveness and suitability for detecting theileriosis. The DNA concentration with 100 µL of blood was highest for Tris-HCL EDTA protocol (A) 209.6 ng/µL, followed by phenol-chloroform pr
APA, Harvard, Vancouver, ISO, and other styles
38

Schwimer, Danielle, Salah Al-Zaiti, and Michael Beach. "Improving Corrected QT Interval Monitoring in Critical Care Units: A Single Center Report." Critical Care Nurse 42, no. 1 (2022): 33–43. http://dx.doi.org/10.4037/ccn2022465.

Full text
Abstract:
Background Corrected QT (QTc) interval prolongation is a type of ventricular tachyarrhythmia. Recommendations for QTc interval monitoring for critical care nurses are limited and variable. Local Problem The intensive care unit at the study institution had no policies for QTc interval monitoring. A quality improvement initiative for identifying and monitoring at-risk patients was begun. Methods A QTc interval monitoring protocol was developed according to current recommendations for electrocardiogram monitoring and input from experts. Nursing staff received education on the QTc monitoring proto
APA, Harvard, Vancouver, ISO, and other styles
39

Kukuh Prayogi, Panji, Mira Orisa, and FX Ariwibisono. "RANCANG BANGUN SISTEM MONITORING JARINGAN ACCESS POINT MENGGUNAKAN SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP) BERBASIS WEB." JATI (Jurnal Mahasiswa Teknik Informatika) 4, no. 1 (2020): 192–97. http://dx.doi.org/10.36040/jati.v4i1.2327.

Full text
Abstract:
Proses monitoring jaringan access point terkadang membuat penyedia layanan harus selalu mendatangi titik access point untuk melakukan controlling. Tidak akan menjadi masalah apabila titik layanan access point hanya 1, namun jika dalam sekala yang cukup besar maka hal ini tentu akan menyita waktu cukup banyak. belum lagi administrator juga harus selalu mematikan dan menghidupkan perangkat guna mereset data cache nya setiap minggu.
 Untuk memecahkan masalah tersebut usaha yang dilakukan adalah dengan membangun sistem monitor access point menggunakan protokol sederhana yaitu dengan Simple Ne
APA, Harvard, Vancouver, ISO, and other styles
40

Ao, Chao Hua, and Xiao Yi Yang. "Monitoring System of Gas Stations in Retail Network of Oil Products." Advanced Materials Research 482-484 (February 2012): 2315–21. http://dx.doi.org/10.4028/www.scientific.net/amr.482-484.2315.

Full text
Abstract:
Aimed at the puzzle of data integration share resulted from its diversity and privacy of protocols in the monitoring system for gas stations in China, the paper designed a monitoring system of gas stations in retail network for oil products. Based on the embedded dynamic Web, it constructed the system frame, built the software system structure, researched the protocol conversion among the forecourt equipments and the module of IFSF, designed message transmission module of IFSF protocol on TCP/IP based on Ethernet, and realized the integrated management between gas stations equipment and system
APA, Harvard, Vancouver, ISO, and other styles
41

da Cruz, Mariângela Guanaes Bortolo. "Pioneer Protocol for Monitoring Pesticides in Water, State of São Paulo, Brazil." Public Health Open Access 7, no. 1 (2023): 1–5. http://dx.doi.org/10.23880/phoa-16000246.

Full text
Abstract:
Pesticides protect crops against pests, but are harmful to human health when ingested through contaminated food and water. While developed countries seek to ban the use of pesticides, developing countries use many of these chemicals, already banned in developed countries. Brazil is the world's largest producer of crops for humans and animals and the state of São Paulo is one of the largest consumers of these chemicals in the country. This research sought to create a methodology for the investigation of pesticides in water, avoiding unnecessary laboratory expenses, aiming at protecting human he
APA, Harvard, Vancouver, ISO, and other styles
42

Dr. Abhishek Badholia, Kanak Prabha Lila Ramani,. "CLUSTER BASED ROUTING PROTOCOLS IN WSN SENSOR." INFORMATION TECHNOLOGY IN INDUSTRY 9, no. 1 (2021): 198–206. http://dx.doi.org/10.17762/itii.v9i1.119.

Full text
Abstract:
Over the past few years we can observe the WSNs or Wireless Sensor Network applications in various fields increasing immensely. The energy efficiency, network lifetime and clustering process prime goal is the working network's optimization is the focus of many of the routing algorithm. Keeping in mind the network homogeneity, for network performance reinforcement we suggest instead of single path to use multiple paths. For WSNs, Reinforcement Intelligence Routing Protocol (RIRP)[1]. In the multihop wireless sensor networks an efficient and effective method for security improvements local monit
APA, Harvard, Vancouver, ISO, and other styles
43

Rovira, Albert, Darwin Reicks, and Claudia Muñoz-Zanzi. "Evaluation of Surveillance Protocols for Detecting Porcine Reproductive and Respiratory Syndrome Virus Infection in Boar Studs by Simulation Modeling." Journal of Veterinary Diagnostic Investigation 19, no. 5 (2007): 492–501. http://dx.doi.org/10.1177/104063870701900506.

Full text
Abstract:
Because porcine reproductive and respiratory syndrome virus (PRRSV) can be transmitted through semen, PRRSV-free boar studs need to be routinely monitored to rapidly detect any potential PRRSV introduction. However, current protocols for monitoring PRRSV in boar studs are diverse, sometimes very costly, and their effectiveness has not been quantified. The objective of this study was to evaluate the ability of different monitoring protocols to detect PRRSV introduction into a negative boar stud by using a simulation modeling approach. A stochastic transmission model was constructed to simulate
APA, Harvard, Vancouver, ISO, and other styles
44

Stevenson, Lucia Jane, Leigh Biagio-de Jager, Marien Alet Graham, and De Wet Swanepoel. "Community-Based Ototoxicity Monitoring for Drug-Resistant Tuberculosis in South Africa: An Evaluation Study." International Journal of Environmental Research and Public Health 18, no. 21 (2021): 11342. http://dx.doi.org/10.3390/ijerph182111342.

Full text
Abstract:
In response to the drug-resistant tuberculosis (DRTB) ototoxicity burden in South Africa, ototoxicity monitoring has been decentralised, with community health workers (CHWs) acting as facilitators. This study describes a community-based ototoxicity monitoring programme (OMP) for patients with DRTB. Findings are compared to the recommended guidelines for ototoxicity monitoring, the OMP protocol and published studies. This was a retrospective study of longitudinal ototoxicity monitoring of 831 patients with DRTB, using data collected at community-based clinics in the City of Cape Town between 20
APA, Harvard, Vancouver, ISO, and other styles
45

Abood, Amany Mohammad, Maysam Sameer Hussein, Zainab G. Faisal, and Zainab H. Tawfiq. "Design and simulation of video monitoring structure over TCP/IP system using MATLAB." Indonesian Journal of Electrical Engineering and Computer Science 24, no. 3 (2021): 1840. http://dx.doi.org/10.11591/ijeecs.v24.i3.pp1840-1845.

Full text
Abstract:
Video monitoring systems are undergoing an evolution from conventional analog to digital clarification to provide better rate and security over internet protocols. In addition, analog surveillance becomes insufficient to face enormous demand of security of system contains more than hundreds of camera often deployed in hotels environments far away from room control. This paper presents the design and simulation of a video monitoring scheme in excess of a transmission control protocol/internet protocol (TCP/IP) system using MATLAB. Sophisticated cameras could record directly high-definition digi
APA, Harvard, Vancouver, ISO, and other styles
46

Abood, Amany Mohammad, Maysam Sameer Hussein, Zainab G. Faisal, and Zainab H. Tawfiq. "Design and simulation of video monitoring structure over TCP/IP system using MATLAB." Indonesian Journal of Electrical Engineering and Computer Science 24, no. 3 (2021): 1840–45. https://doi.org/10.11591/ijeecs.v24.i3.pp1840-1845.

Full text
Abstract:
Video monitoring systems are undergoing an evolution from conventional analog to digital clarification to provide better rate and security over internet protocols. In addition, analog surveillance becomes insufficient to face enormous demand of security of system contains more than hundreds of camera often deployed in hotels environments far away from room control. This paper presents the design and simulation of a video monitoring scheme in excess of a transmission control protocol/internet protocol (TCP/IP) system using MATLAB. Sophisticated cameras could record directly highdefinition digit
APA, Harvard, Vancouver, ISO, and other styles
47

Warsito, Ary Budi, Muhamad Yusup, and Rivai Sungkowo. "DATABASE HEALTH MONITORING (DHM) SEBAGAI ALAT MONITORING KESEHATAN DATABASE." CCIT Journal 9, no. 3 (2016): 312–17. http://dx.doi.org/10.33050/ccit.v9i3.465.

Full text
Abstract:
DSS (Decision Support Systems) has the notion that a computer-based system that presents and process information that allows decisions to be more productive, dynamic and innovative [1]. In this study, a concept with the name DHM (Database Health Monitoring). DHM concept is a form of development of the DSS is a concept of how to analyze the health of a database in which the level of health in the database is measured by the number of empty fields. To calculate the number of empty fields required sql queries which query results are then processed into a protocol JSON (JavaScript Object Notation)
APA, Harvard, Vancouver, ISO, and other styles
48

Babiker, Ammar, Mohamed Elmaleeh, Onaytra Abbas, and Abbdelrahman Osman Elfaki. "Data-Based Energy Efficient Clustered Routing Protocol for Wireless Sensors Networks – Tabuk Flood Monitoring System Case Study." International Journal of Recent Contributions from Engineering, Science & IT (iJES) 5, no. 3 (2017): 58. http://dx.doi.org/10.3991/ijes.v5i3.7529.

Full text
Abstract:
<p>Energy efficiency has been considered as the most important issue in wireless sensor networks. As in many applications, wireless sensors are scattered in a wide harsh area, where the battery replacement or charging will be quite difficult and it is the most important challenge. Therefore, the design of energy saving mechanism becomes mandatory in most recent research. In this paper, a new energy efficient clustered routing protocol is proposed: the proposed protocol is based on analyzing the data collected from the sensors in a base-station. Based on this analysis the cluster head wil
APA, Harvard, Vancouver, ISO, and other styles
49

S, Srinitha. "Induction Motor Efficiency Monitoring using CAN Protocol." International Journal for Research in Applied Science and Engineering Technology V, no. III (2017): 1205–8. http://dx.doi.org/10.22214/ijraset.2017.3221.

Full text
APA, Harvard, Vancouver, ISO, and other styles
50

Firdaus, Caesar, Wahyudin Wahyudin, and Eddy Prasetyo Nugroho. "Monitoring System with Two Central Facilities Protocol." Indonesian Journal of Science and Technology 2, no. 1 (2017): 8. http://dx.doi.org/10.17509/ijost.v2i1.5986.

Full text
Abstract:
The security of data and information on government’s information system required proper way of defending against threat. Security aspect can be achieved by using cryptography algorithm, applying information hiding concept, and implementing security protocol. In this research, two central facilities protocol was implemented on Research and Development Center of Mineral and Coal Technology’s Cooperation Contract Monitoring System by utilizing AES and whitespace manipulation algorithm. Adjustment on the protocol by creating several rule of validation ID’s generation and checking processes could f
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!