Academic literature on the topic 'Nailing System'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Nailing System.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Nailing System"

1

Guo, Bing. "Simulation and Analysis on Supporting System of Composite Soil Nailing Technology in the Process of Digging." Advanced Materials Research 568 (September 2012): 66–70. http://dx.doi.org/10.4028/www.scientific.net/amr.568.66.

Full text
Abstract:
According to the typical engineering example and the structural features of the supporting system of composite soil nailing technology, the computing mode of deformation of composite soil nailing technology under force is established. Numerical analysis and supervision in the process of construction on composite soil nailing technology are made with the collocation of typical project example. The data of monitoring on the spot and numerical simulation show that the supporting system of composite soil nailing technology meets the requirement of real deformation under force and can simulate the
APA, Harvard, Vancouver, ISO, and other styles
2

Kumar, Prashant. "Clinical Performance of Intramedullary Nailing system for Tibia Fractures: A Retrospective study." International Journal of Clinical Case Reports and Reviews 7, no. 03 (2021): 01–05. http://dx.doi.org/10.31579/2690-4861/124.

Full text
Abstract:
Background: The tibia, or shinbone, is the common fracture long bone in body. There are two option includes, reamed and unreamed of surgical treatment of fractures. Reamed nail has some advantage but they significantly harmful the endosteal circulation. Unreamed nail surplus the endosteal circulation but provide a less stable fixation. Afterward, because of ability to lock the nail proximally and distally, closed intramedullary nailing turned into an acknowledged treatment for closed shaft cracks during the ninth decade. Aim: The main objective is to treat the tibia fractures by implanting the
APA, Harvard, Vancouver, ISO, and other styles
3

Panthi, Sagar, Rishiswor Shrestha, Jigyasu Pradhan, Bikash Neupane, Ishory Bhusal, and Angelica Karki. "Diaphyseal Femur Fracture in Paediatric Age group: Outcome with fixation by Elastic Nailing System." Europasian Journal of Medical Sciences 3, no. 1 (2021): 1–5. http://dx.doi.org/10.46405/ejms.v3i1.258.

Full text
Abstract:
Background: Diaphyseal femur fracture in paediatric age group account for 1.6% of all paediatric fractures. Fracture fixation by elastic nail provides three point fixation. This study aims to assess the outcome of diaphyseal femur fracture in paediatric age group from 5 to 15 years treated with titanium elastic nailing system.Methods: Thirty six patients with diaphyseal femur fracture were treated with titanium elastic nailing system from November 2018 to August 2020 was analyzed prospectively. All the patients were followed up for six months for the study. Final outcome was evaluated at six m
APA, Harvard, Vancouver, ISO, and other styles
4

Siddhartha, Kumar Shrest, Priyadarshi Prashant, and Azam Maseeh. "Titanium Elastic Anchoring System for Surgical Management of Midshaft Clavicle Fracture." International Journal of Pharmaceutical and Clinical Research 15, no. 10 (2023): 1367–70. https://doi.org/10.5281/zenodo.11302674.

Full text
Abstract:
<strong>Background:</strong>&nbsp;About 76% of all clavicular fractures are midclavicular fractures, which are frequent clinically. A previously unknown prevalence of malunion and non-union after conservative treatment of more severe midclavicular fractures has been found by recent investigations. This study&rsquo;s objective was to assess the clinical results of titanium elastic nail treatment for midclavicular fractures.&nbsp;<strong>Methods:</strong>&nbsp;A prospective hospital-based study carried out at JLNMCH, Bihar, India. 60 patients between the ages of 18 and 50 who had displaced midsh
APA, Harvard, Vancouver, ISO, and other styles
5

Madhusudhan Reddy P, M. "Paediatric Long Bone Fracture Managed with Titanium Elastic Nailing System." International Journal of Science and Research (IJSR) 13, no. 4 (2024): 828–31. http://dx.doi.org/10.21275/sr24408174709.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Butt, Muhammad Farooq, Saqib Ayaz, Irfan Malik, M. Anwar Ahmed, and Zubair Ahmad Lone. "Functional and radiological outcome of both bone fracture forearm in children managed with titanium elastic nailing system." International Journal of Research in Medical Sciences 13, no. 4 (2025): 1467–71. https://doi.org/10.18203/2320-6012.ijrms20250966.

Full text
Abstract:
Background: Forearm diaphyseal fracture is one of the three common upper limb fractures in the pediatric population. With many known methods of treatment available, the authors present their experience of managing these injuries by titanium elastic nailing system. Methods: The present study was a prospective study of 3 years duration which included 50 patients. All patients underwent elastic nailing of both radius and ulna in the same sitting. Analysis of pre-operative and post-operative radiographs of forearm, taken in two orthogonal views, was done. Final functional outcome was graded clinic
APA, Harvard, Vancouver, ISO, and other styles
7

TUKADA, Takao, Yasuhiro NAITO, and Toshiharu KAGAWA. "DYNAMIC RESPONSE OF HIGH PRESSURE NAILING SYSTEM." Proceedings of the JFPS International Symposium on Fluid Power 1996, no. 3 (1996): 663–66. http://dx.doi.org/10.5739/isfp.1996.663.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Fortis, A. P., A. Dimas, and A. A. Lamprakis. "Expandable nailing system for tibial shaft fractures." Injury 39, no. 8 (2008): 940–46. http://dx.doi.org/10.1016/j.injury.2008.01.022.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Fortis, A., A. Dimas, and A. Lamprakis. "Expandable nailing system for tibial shaft fractures." Injury Extra 40, no. 10 (2009): 219. http://dx.doi.org/10.1016/j.injury.2009.06.262.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Chan, K. W., J. Wong, and N. W. Thompson. "AO approved nailing system: is it effective?" Injury Extra 41, no. 12 (2010): 181. http://dx.doi.org/10.1016/j.injury.2010.07.364.

Full text
APA, Harvard, Vancouver, ISO, and other styles
More sources

Dissertations / Theses on the topic "Nailing System"

1

Morley, John Russell. "Stimulation of the inflammatory response system by femoral intramedullary nailing : the source of the second hit phenomenon." Thesis, University of Leeds, 2006. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.439552.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Nemchand, Jaya Luxshmi. "Smart implant : the biomechanical testing of instrumented intramedullary nails during simulated callus healing using telemetry for fracture healing monitoring." Thesis, Brunel University, 2015. http://bura.brunel.ac.uk/handle/2438/11592.

Full text
Abstract:
The purpose of this study is to investigate the effect of loading during long bone fracture healing in-vitro and in-vivo. Fracture healing has until now only been monitored using radiographs and ultrasound. An intramedullary nail instrumented with strain gauges has the potential to monitor loading in-vivo during bone fracture healing. Strain has been previously monitored over time though external fixation devices however there has been no published data about monitoring through a nail. The load carried by a telemetric intramedullary nail during simulated fracture healing is monitored in-vitro
APA, Harvard, Vancouver, ISO, and other styles
3

Giacon, Lorenzo. "Flexible facings for soil nailing retaining systems." Master's thesis, Alma Mater Studiorum - Università di Bologna, 2012. http://amslaurea.unibo.it/3376/.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Wu, Zhen-Tao, and 吳臻燾. "Utilizing Monitoring System to Prove a Freeway Gravel Slope of Soil Nailing Method." Thesis, 2005. http://ndltd.ncl.edu.tw/handle/vy8qv4.

Full text
Abstract:
碩士<br>朝陽科技大學<br>營建工程系碩士班<br>93<br>The gravel slope design of the South Highway 3, vegetation belt pavement method and thin layer hydrograsser method slope protection methods were used. When it rains, the slope corrodes easily, and form ditches that drains the fine topsoil. As a result, during the dry season in southern Taiwan, it is difficult for plant life to grow, and does not achieve the necessary effect. The goal of this research is to suggest which method is more suitable for the existing gravel slopes, and carry out a discussion on the stability of the gravel slope. First, an on-site exp
APA, Harvard, Vancouver, ISO, and other styles

Books on the topic "Nailing System"

1

Withiam, James L. Recommended practice for evaluation of metal-tensioned systems in geotechnical applications. National Academy Press, 2002.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
2

French National Research Project Clouterre., ed. Recommendations Clouterre 1991: Soil nailing recommendations 1991, for designing, calculating, constructing and inspecting earth support systems using soil nailing. Federal Highway Administration, 1993.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
3

United States. Federal Highway Administration., ed. Recommendations clouterre 1991: Soil nailing recommendations--1991 for designing, calculating, constructing and inspecting earth support systems using soil nailing. U.S. Dept. of Transportation, Federal Highway Administration, 1993.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
4

Fishman, Kenneth L. LRFD metal loss and service-life strength reduction factors for metal-reinforced systems. Transportation Research Board, 2011.

Find full text
APA, Harvard, Vancouver, ISO, and other styles

Book chapters on the topic "Nailing System"

1

Gill, Damien F., Fouzia Khatun, and Wasim S. Khan. "The Interlocking Nailing System and Technique." In General Principles of Orthopedics and Trauma. Springer International Publishing, 2019. http://dx.doi.org/10.1007/978-3-030-15089-1_31.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Auer, Michael. "Soil Nailing, the Variable Static System of the Future." In Springer Series in Geomechanics and Geoengineering. Springer International Publishing, 2015. http://dx.doi.org/10.1007/978-3-319-11053-0_25.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Nagalakshmi, M., and C. N. V. Satyanarayana Reddy. "Development of Rational Method of Design of Soil Nailing System in Granular Soil." In Lecture Notes in Civil Engineering. Springer Singapore, 2021. http://dx.doi.org/10.1007/978-981-16-5601-9_30.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Nakdhamabhorn, Sakol, and Jackrit Suthakorn. "On the Design and Experiments of a Fluoro-Robotic Navigation System for Closed Intramedullary Nailing of Femur." In Recent Advances in Computer Science and Information Engineering. Springer Berlin Heidelberg, 2012. http://dx.doi.org/10.1007/978-3-642-25789-6_29.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Askarinejad Amin, Shahnazari Habib, and Salehzadeh Hosseyn. "Investigation of the behaviour of nailed sand trenches before failure by geotechnical centrifuge." In Proceedings of the 17th International Conference on Soil Mechanics and Geotechnical Engineering. IOS Press, 2009. https://doi.org/10.3233/978-1-60750-031-5-436.

Full text
Abstract:
The main purpose of this paper is the study of the pre-failure behaviour of loose vertical sand slopes stabilized by nailing system. In this research a series of centrifuge tests have been done and the behaviour of nailed vertical sand slopes has been traced in flight either by instrumentation or by image processing techniques.
APA, Harvard, Vancouver, ISO, and other styles
6

de Moura Costa Clovis Fernando and Garcia Matheus. "Secured drapery system in the highway BR 163, Nobres &ndash; MT, Brazil. The use of steel mesh." In Integrating Innovations of Rock Mechanics. IOS Press, 2015. https://doi.org/10.3233/978-1-61499-605-7-125.

Full text
Abstract:
The highway BR 163 near the city Nobres, Mato Grosso State in Brazil has slopes with falling arenite blocks (fig. 1). The solution to this problem was a metallic mesh with a patterned of anchors. The software MACRO 1, from Maccaferri, was used to design the system. A secured drapery system, consisting of rockfall netting and a systematic nailing scheme, is designed to stabilize surficial material on an exposed rock face. The design procedure can be very complicated because the geomechanical models are very complex or unrealistic, and obtaining accurate input data is rather problematic. This pa
APA, Harvard, Vancouver, ISO, and other styles
7

Park, S., C. Yoo, and H. Kim. "Laboratory tests and numerical analysis for development of self drilled soil nailing system." In Physical Modelling in Geotechnics. Taylor & Francis, 2006. http://dx.doi.org/10.1201/noe0415415866.ch225.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Dai, H., X. Xiong, and M. Wu. "Research on factors influence of deep foundation structured by soil nailing based on grey system theory." In Rock Mechanics: Achievements and Ambitions. CRC Press, 2011. http://dx.doi.org/10.1201/b11438-92.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Gobbi Felipe, Fonini Anderson, Tobler Daniel, et al. "Pit Slope Recovery &ndash; &Aacute;guas Claras Mine." In From Fundamentals to Applications in Geotechnics. IOS Press, 2015. https://doi.org/10.3233/978-1-61499-603-3-3264.

Full text
Abstract:
In 1992 a massive landslide had occurred at &amp;Aacute;guas Claras Mine, at that time it was operated by Minera&amp;ccedil;&amp;otilde;es Brasileiras Reunidas, MBR. After this event slope stability studies were carried out in order to evaluate the remaining slope, which were considered acceptable. However erosion process leaded to shallow landslides -hence the crest of the mountain become a risk area, which is part of the national heritage Serra do Curral landscape. As consequence, in 2008 a stabilization solution consisting in a soil/rock nailing faced with high strength steel wire mesh and
APA, Harvard, Vancouver, ISO, and other styles
10

Hibbert, D. Brynn. "Quality Control Tools." In Quality Assurance in the Analytical Chemistry Laboratory. Oxford University Press, 2007. http://dx.doi.org/10.1093/oso/9780195162127.003.0008.

Full text
Abstract:
Although thoroughly convinced that no laboratory can function without proper regard to quality in all its myriad forms, the question remains, What do we do? As a quality control manager with a budget and the best aspirations possible, what are the first steps in providing your laboratory or company with an appropriate system (other than buying this book, of course)? Each laboratory is unique, and what is important for one may be less important for another. So before buying software or nailing control charts to your laboratory door, sit down and think about what you hope to achieve. Consider ho
APA, Harvard, Vancouver, ISO, and other styles

Conference papers on the topic "Nailing System"

1

Lim, Chun-Lan, and Chee-Ming Chan. "An alternative soil nailing system for slope stabilization: Akarpiles." In PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON CONSTRUCTION AND BUILDING ENGINEERING (ICONBUILD) 2017: Smart Construction Towards Global Challenges. Author(s), 2017. http://dx.doi.org/10.1063/1.5011610.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Budimir, Vjekoslav, and Armin Roduner. "STRUCTURAL REINFORCEMENT OF GEO-MAT BY HIGH-TENSILE STEEL WIRE MESHES." In GEO-EXPO 2020. DRUŠTVO ZA GEOTEHNIKU U BOSNI I HERCEGOVINI, 2020. http://dx.doi.org/10.35123/geo-expo_2020_9.

Full text
Abstract:
For a successful and long-term stabilization of natural embankments and new cuttings in loose rock, their effective revegetation is very important. In combination with hydro or dry seeding, geo-mat - so-called three-dimensional erosion control mats made of polypropylene are very effective. On the one hand, the 3D structure reduces the impact energy of raindrops, and the drag force of the draining water is reduced. Geotextiles and geo-mats, which are used as planting aids, usually have only a low strength and are therefore only effective for low slope angles, or in combination with a stabilizat
APA, Harvard, Vancouver, ISO, and other styles
3

Park, S. S., and H. T. Kim. "Design and Stability Analysis of a Novel Pretensioned Soil Nailing System in Korea." In GeoShanghai International Conference 2006. American Society of Civil Engineers, 2006. http://dx.doi.org/10.1061/40863(195)34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Liu, Jian, Ke Shang, and Xing Wu. "Stability Analysis of Soil Nailing Supporting Structure Based on System Failure Probability Method." In Geo-Hubei 2014 International Conference on Sustainable Civil Infrastructure. American Society of Civil Engineers, 2014. http://dx.doi.org/10.1061/9780784478523.006.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Budimir, Vjekoslav, Armin Roduner, and Helene Hofmann. "Slope stabilisation using high-tensile stainless-steel wire mesh." In 6th International Conference on Road and Rail Infrastructure. University of Zagreb Faculty of Civil Engineering, 2021. http://dx.doi.org/10.5592/co/cetra.2020.1106.

Full text
Abstract:
Slope stabilisation systems with meshes made of high-tensile steel wire have been in use for 20 years and have proven to be reliable systems on loose rock and soil slopes. The optimization of the nailing pattern thanks to the high load bearing capacity of the system permits a reduction of the overall costs and represents an economical solution as well as an ecological solution. The expected service life with regards to corrosion depends, in addition to the corrosion protection used, on the environmental conditions and the corresponding chemical wear. The definition of aggressive corrosive envi
APA, Harvard, Vancouver, ISO, and other styles
6

Tsujita, T., A. Konno, S. Komizunai, et al. "Analysis of nailing task motion for a humanoid robot." In 2008 IEEE/RSJ International Conference on Intelligent Robots and Systems. IEEE, 2008. http://dx.doi.org/10.1109/iros.2008.4651160.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Varanda, Erica, José Pereira Soares, and Roberta Amorim Leite. "Emergency Actions for Containing Side Slope to the Pipeline Range." In ASME 2013 International Pipeline Geotechnical Conference. American Society of Mechanical Engineers, 2013. http://dx.doi.org/10.1115/ipg2013-1917.

Full text
Abstract:
After a period of heavy rainfall, the landslide of a mass of residual soil in the side slope to the Pipeline Range of PETROBRAS occurred, in which two oil pipelines and gas pipeline connecting a terminal to a refinery. On the day following the event in field inspection performed by the TRANSPETRO team, it was found that due to the landslide, the gas pipeline was exposed, with a Section of approximately 8.0 meters apparent in a slope at risk of undergoing deformations with the movement of unstable soil. In the course of the inspection several indications soil movement were observed, such as cra
APA, Harvard, Vancouver, ISO, and other styles
8

Salas, Christina, Deana Mercer, Thomas A. DeCoster, and Mahmoud M. Reda Taha. "Experimental and Probabilistic Finite Element Analysis of Distal Femoral Fractures: A Comparison of Locking Plate Versus Intramedullary Nail Fixation." In ASME 2010 Summer Bioengineering Conference. American Society of Mechanical Engineers, 2010. http://dx.doi.org/10.1115/sbc2010-19303.

Full text
Abstract:
In the treatment of unstable, distal, metaphyseal femoral fractures, surgeons have multiple implant options for fixation. Biomechanical studies of intramedullary nailing systems and locking plates have shown that both systems achieve stable fixation of the fracture to allow healing.1–3 These systems are indicated for comminuted fractures, non-unions, and osteoporotic bone where distal femur fractures are associated with a 20% mortality rate in elderly individuals.4 Though capable of achieving stable fixation, both locking and non-locking plates have been associated with periprosthetic fracture
APA, Harvard, Vancouver, ISO, and other styles
9

Hongguo, Dong, Wei Longfei, Wu Shujing, et al. "Model Test Study of Soil Nailing Wall in Silty Clay in Beijing." In 2014 Fifth International Conference on Intelligent Systems Design and Engineering Applications (ISDEA). IEEE, 2014. http://dx.doi.org/10.1109/isdea.2014.260.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

"Bone Surface Segmentation in Ultrasound Images: Application in Computer Assisted Intramedullary Nailing of the Tibia Shaft." In 2nd International Workshop on Medical Image Analysis and Description for Diagnosis Systems. SciTePress - Science and and Technology Publications, 2011. http://dx.doi.org/10.5220/0003307600340042.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Reports on the topic "Nailing System"

1

Touch Surgery. AO Intramedullary Fixation of a Proximal Femoral Fracture Using a TFN-Advanced Nailing System. Touch Surgery Publications, 2018. http://dx.doi.org/10.18556/touchsurgery/2016.s0148.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Wilkey, Keith D., and William Mehserle. Mechanical Characteristics of the Femoral Intramedullary Nailing Systems Available from Five Different Manufacturers. Defense Technical Information Center, 1995. http://dx.doi.org/10.21236/ada313110.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

AO Intramedullary Fixation of a Proximal Femoral Fracture Using a TFN-Advanced Nailing System. Touch Surgery Simulations, 2018. http://dx.doi.org/10.18556/touchsurgery/2018.s0148.

Full text
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!