To see the other types of publications on this topic, follow the link: Nickel-titanium.

Journal articles on the topic 'Nickel-titanium'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 journal articles for your research on the topic 'Nickel-titanium.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse journal articles on a wide variety of disciplines and organise your bibliography correctly.

1

Chidambaram, S., M. Vijay, D. Praveen Kumar Varma, K. Baburam Reddy, D. Ravindranath, and M. Rajendra Prasad. "Comparison of Galvanic Corrosion Potential of Metal Injection Molded Brackets to that of Conventional Metal Brackets with Nickel-Titanium and Copper Nickel-Titanium Archwire Combinations." Journal of Contemporary Dental Practice 14, no. 3 (2013): 488–95. http://dx.doi.org/10.5005/jp-journals-10024-1350.

Full text
Abstract:
ABSTRACT Aim The aim of the study is to investigate the galvanic corrosion potential of metal injection molding (MIM) brackets to that of conventional brackets under similar in vitro conditions with nickel-titanium and copper nickel-titanium archwires. Materials and methods Twenty-five maxillary premolar MIM stainless steel brackets and 25 conventional stainless steel brackets and archwires, 0.16 inch, each 10 mm length, 25 nickeltitanium wires, 25 copper nickel-titanium wires were used. They were divided into four groups which had five samples each. Combination of MIM bracket with copper nick
APA, Harvard, Vancouver, ISO, and other styles
2

Prakash, Divya, Kishlay Kant Singh, and Mansi Saini. "Revolutionizing Surgical Instrument Reuse: Microbial Action for Nickel Toxicity Removal from Titanium Implements." Oriental Journal Of Chemistry 40, no. 5 (2024): 1491–98. http://dx.doi.org/10.13005/ojc/400533.

Full text
Abstract:
This work investigates the use of microbial activities to reduce nickel toxicity from old titanium surgical instruments as a means of mitigating metal toxicity. Through efficient purification, these instruments can be reused in a sustainable manner, supporting both economical healthcare practices and environmental preservation. Surgical instruments made of titanium are widely used in the medical profession; however, these devices can become contaminated or hazardous due to the accumulation of nickel over time. The main goal of this study is to employ microbiological action to remove nickel fro
APA, Harvard, Vancouver, ISO, and other styles
3

Suárez, Carlos, Teresa Vilar, Pablo Sevilla, and Javier Gil. "In Vitro Corrosion Behavior of Lingual Orthodontic Archwires." International Journal of Corrosion 2011 (2011): 1–9. http://dx.doi.org/10.1155/2011/482485.

Full text
Abstract:
Objectives. To investigate the in vitro electrochemical corrosive behavior of archwires used in lingual orthodontics and the effects on the phase transition temperatures.Materials and Methods. Six different types of archwires of stainless steel, titanium-molybdenum, nickel-titanium and nickel-titanium-copper were used. Corrosion tests were performed following ISO-standard 10993-15:2000. Differential scanning calorimetry and scanning electron microscopy were used.Results. The stainless steel archwires showed anEpitaround −600 mV, and those of titanium alloys showedEpitvalues around 1000 mV. Dif
APA, Harvard, Vancouver, ISO, and other styles
4

Khabadze, Z. S., and F. R. Ismailov. "Investigation of cyclic fatigue of rotary endodontic instruments." Endodontics Today 20, no. 1 (2022): 28–35. http://dx.doi.org/10.36377/1683-2981-2022-20-1-28-35.

Full text
Abstract:
Aim. To study the properties and resistance to cyclic loading of nickel-titanium files with a martensitic phase. The use of nickel-titanium instruments is an integral part of the endodontic treatment of root canals. During endodontic treatment, nickel-titanium instruments experience a huge load, which is manifested by fatigue of nickel-titanium instruments, in the form of a fracture.Purpose. To determine the resistance of nickel-titanium files to mechanical, chemical and temperature stress.Materials and methods. A nickel-titanium file with a martensitic S-flexi phase from Geosoft was selected
APA, Harvard, Vancouver, ISO, and other styles
5

Elkiran, Ozlem, Cemsit Karakurt, Gulendam Kocak, and Cagatay Taskapan. "Serum Nickel and Titanium Levels after Transcatheter Closure of Atrial Septal Defects with Amplatzer Septal Occluder." Cardiology Research and Practice 2019 (January 2, 2019): 1–6. http://dx.doi.org/10.1155/2019/7891746.

Full text
Abstract:
Introduction. There is a concern about release of nickel and titanium after implantation of nitinol-containing devices.Objective. To evaluate serum nickel and titanium release after implantation of Amplatzer occluder.Materials and methods. In 38 pediatric patients with no history of nickel sensitivity, blood samples were drawn 24 hours before and 24 hours, 1, 3, 6, and 12 months after implantation. Nickel and titanium concentrations were measured by atomic absorption spectrophotometry.Results. The median serum nickel level which was 0.44 ng/mL before the implantation increased to 1.01 ng/mL 24
APA, Harvard, Vancouver, ISO, and other styles
6

Rao, J., T. Roberts, K. Lawson, and J. Nicholls. "Nickel titanium and nickel titanium hafnium shape memory alloy thin films." Surface and Coatings Technology 204, no. 15 (2010): 2331–36. http://dx.doi.org/10.1016/j.surfcoat.2009.12.025.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Ye, H. Q. "Structure of mechanically alloyed nickel and titanium-nickel/titanium carbide composites." Metal Powder Report 51, no. 1 (1997): 36. http://dx.doi.org/10.1016/s0026-0657(97)80104-x.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Ovcharenko, V. V., A. N. Monogenov, Yu F. Yasenchuk, and V. É. Gyunter. "The structure of porous nickel titanium reinforced by monolithic nickel titanium." Technical Physics Letters 32, no. 4 (2006): 288–91. http://dx.doi.org/10.1134/s1063785006040043.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Wong, E. K. F., D. W. Borland, and V. C. West. "Deformation of Orthodontic Archwires Over Time." Australasian Orthodontic Journal 13, no. 3 (1994): 152–58. http://dx.doi.org/10.2478/aoj-1994-0018.

Full text
Abstract:
Abstract Most previous studies of archwire deformation over time (hereafter referred to as “time-dependent deformation of orthodontic wires”) have been conducted at a constant room temperature. In the clinical situation however, arch wires are exposed to 37°C as well as to periods of temperature increase when hot foods or fluids are ingested. The effects of the latter on time-dependent behaviour are largely unknown. Since the introduction of direct electric resistance heat treatment to superelastic nickel titanium wires, there have been no reports on its effect on time-dependent deformation. T
APA, Harvard, Vancouver, ISO, and other styles
10

Dombrovskaya, Yu A., T. O. Paderina, K. A. Benken, E. Yu Lubskaya, and A. V. Silin. "Comparative morphometric characteristics of the working surface of endodontic rotary nickel-titanium instruments after maximum cyclic loading." Endodontics Today 20, no. 1 (2022): 12–19. http://dx.doi.org/10.36377/1683-2981-2022-20-1-12-19.

Full text
Abstract:
Aim. Is the morphometric analysis of the working surfaces of endodontic rotating nickel-titanium instruments.Materials and methods. The chemical composition and physical properties of the three types of endodontic rotating nickel-titanium F2 instruments have been analyzed: proptaper Universal (PTu, Dentsply, Maillefer, Ballaigues, Switzeland), Ultrataper (Eurofile, China) and Superfile (Eurofile, China) protapers. The evaluation of endodontic treatment of 75 endoblocks was also carried out.Results. The research work shows that endodontic rotary instruments have both different chemical composit
APA, Harvard, Vancouver, ISO, and other styles
11

Du, Junliang, Feifei Wang, Zhuo Wang, Xuemei Wang, and Xinzhen Du. "Morphology, composition and selectivity of nickel/titanium oxide nanoflakes grown on a superelastic nickel/titanium alloy fiber substrate for highly efficient solid-phase microextraction of aromatic compounds." Analytical Methods 11, no. 9 (2019): 1237–47. http://dx.doi.org/10.1039/c9ay00071b.

Full text
APA, Harvard, Vancouver, ISO, and other styles
12

Kaur, Sharnjeet, Sudhir Munjal, Amanpreet S. Natt, Karan Maheshwari, Gagandeep Singh, and Amanjot Kaur Bajwa. "Effects of Different Sterilization Methods on Orthodontic Wires: An In Vitro Study." Journal of Pharmacy and Bioallied Sciences 16, Suppl 1 (2024): S152—S155. http://dx.doi.org/10.4103/jpbs.jpbs_432_23.

Full text
Abstract:
ABSTRACT Objective: The purpose of this study was to determine the effect of common methods of sterilization on the tensile strength of Beta titanium, Stainless steel, Australian Stainless steel, Copper Nickel-Titanium, and Nickel-Titanium wires. It also aimed to evaluate the changes in tensile strength values caused by repeated cycles of sterilization. Materials and Methods: A sample of 225 orthodontic wires, i.e., beta-titanium, stainless steel, Australian stainless steel, copper nickel-titanium, and nickel-titanium wires, were collected from different manufacturers. These wires were divided
APA, Harvard, Vancouver, ISO, and other styles
13

Sharma, Madhur, Kalpit Shaha, Hemant Sharma, and Amit Maheshwari. "Titanium dioxide coating on nickel-titanium archwire." American Journal of Orthodontics and Dentofacial Orthopedics 159, no. 5 (2021): 560–61. http://dx.doi.org/10.1016/j.ajodo.2021.01.015.

Full text
APA, Harvard, Vancouver, ISO, and other styles
14

Alzaharnah, Iyad T. "Thermal Stresses in Thick Walled Cylinders due to a Periodic Moving Heat Source: Effect of Material Properties." Advanced Materials Research 445 (January 2012): 627–30. http://dx.doi.org/10.4028/www.scientific.net/amr.445.627.

Full text
Abstract:
nternal heating of hollow cylinders with moving periodic heat source is examined in relation to surface treatment applications. This study includes three different cylinder materials, namely aluminum, nickel and titanium. Effective stresses in the cylinder wall are found to be mainly attributed to longitudinal temperature gradients. The aluminum cylinder shows sharper longitudinal temperature gradients as compared to the nickel and the titanium cylinders, which is due to the high value of the aluminum specific heat capacity. However, the larger Eα (elasticity modulus × thermal expansion coeffi
APA, Harvard, Vancouver, ISO, and other styles
15

Chen, Yi-Cheng, and Shih-Fu Ou. "Effects of Reinforcement Ratios and Sintering Temperatures on the Mechanical Properties of Titanium Nitride/Nickel Composites." Materials 13, no. 20 (2020): 4473. http://dx.doi.org/10.3390/ma13204473.

Full text
Abstract:
In this study, powder metallurgy was used to fabricate titanium nitride/nickel metal-matrix composites. First, titanium and nickel powders with weight ratios of 20:80, 50:50 and 80:20 were dry mixed for 24 h. After cold isostatic pressing, the green compacts were soaked in a water-based hot forging lubricant and sintered at 850, 950 and 1050 °C for 1.5 h in an air atmosphere. The effects of the amounts of titanium powder and the sintering temperatures on the mechanical properties (hardness, wear resistance and compressive strength) of the composites were investigated. The results indicated tha
APA, Harvard, Vancouver, ISO, and other styles
16

de Brito Simões, Jackson, and Carlos José de Araújo. "Nickel–titanium shape memory alloy mechanical components produced by investment casting." Journal of Intelligent Material Systems and Structures 29, no. 19 (2018): 3748–57. http://dx.doi.org/10.1177/1045389x18799197.

Full text
Abstract:
This work aimed to produce mechanical components of nickel–titanium shape memory alloys using investment casting processes. Then, in order to validate processing, different designs of nickel–titanium shape memory alloy components as staple implants, Belleville springs, meshes, helical springs, screws and hexagonal honeycombs were produced and submitted to thermal and mechanical characterization. Thermoelastic martensitic transformation of the nickel–titanium shape memory alloy parts was determined by differential scanning calorimetry and electrical resistance with temperature, while the supere
APA, Harvard, Vancouver, ISO, and other styles
17

Murugan, Ganesh, and Md Shakeb Ahemad. "Management of impinging “Nickel titanium palatal expander” in cleft palate cases by “Soft flow” (temporary mucosal protector)." IP Indian Journal of Orthodontics and Dentofacial Research 9, no. 3 (2023): 203–5. http://dx.doi.org/10.18231/j.ijodr.2023.036.

Full text
Abstract:
The temperature-activated Arndt nickel titanium palatal expander has been a good choice for cleft palate applications because it creates transverse maxillary expansion, uprights and rotates the maxillary molars, and allows a smooth transition to fixed retention with no requirement for patient compliance and little manipulation by the clinician. But the clinical problem sometimes encountered is the impinging of “Nickel-Titanium” metal component of the Nickel titanium palatal expander on the soft palate. “Soft Flow” is a Temporary Mucosal Protector introduced recently in the orthodontic market w
APA, Harvard, Vancouver, ISO, and other styles
18

Waters, N. E. "Superelastic Nickel-titanium Wires." British Journal of Orthodontics 19, no. 4 (1992): 319–22. http://dx.doi.org/10.1179/bjo.19.4.319.

Full text
APA, Harvard, Vancouver, ISO, and other styles
19

Stokes, Orsure W. "Nickel titanium instrumentation panel." Journal of Endodontics 22, no. 8 (1996): 442–43. http://dx.doi.org/10.1016/s0099-2399(96)80253-6.

Full text
APA, Harvard, Vancouver, ISO, and other styles
20

Wang, Fei, Lei Feng, Dongmei Zhang, Qingguo Tang, Jinsheng Liang, and Dan Feng. "Theoretical Study on Electronic Structure and Optical Performance of Nickel and Nitrogen Codoped Rutile Titanium Dioxide." International Journal of Photoenergy 2014 (2014): 1–6. http://dx.doi.org/10.1155/2014/168276.

Full text
Abstract:
The nickel doped, nitrogen doped and nickel + nitrogen codoped rutile titanium dioxide have been investigated by ab initio calculations based on density functional theory. The electronic structure and optical performance of different ions doping models are researched through the obtained results, which reflects that the band gap of nickel and nitrogen codoped system declines apparently; the decrease of electron-hole pairs separation and charge carriers recombination rate becomes more desirable. Moreover, the optical absorption curves of nitrogen and nickel codoped rutile titanium dioxide demon
APA, Harvard, Vancouver, ISO, and other styles
21

Yang, Jun, Yunxia Ping, Wei Liu, et al. "Ti Interlayer Mediated Uniform NiGe Formation under Low-Temperature Microwave Annealing." Metals 11, no. 3 (2021): 488. http://dx.doi.org/10.3390/met11030488.

Full text
Abstract:
The reactions between nickel and germanium are investigated by the incorporation of a titanium interlayer on germanium (100) substrate. Under microwave annealing (MWA), the nickel germanide layers are formed from 150 °C to 350 °C for 360 s in ambient nitrogen atmosphere. It is found that the best quality nickel germanide is achieved by microwave annealing at 350 °C. The titanium interlayer becomes a titanium cap layer after annealing. Increasing the diffusion of Ni by MWA and decreasing the diffusion of Ni by Ti are ascribed to induce the uniform formation of nickel germanide layer at low MWA
APA, Harvard, Vancouver, ISO, and other styles
22

Bolya, Piyush, Nibha Yadav, Vikas Goyal, Shuchi Singh, and Neha Ajmera. "Impact of recycling on efficiency and efficacy of copper nickel titanium wire and heat activated nickel titanium wire – An invitro study." Journal of Contemporary Orthodontics 8, no. 3 (2024): 294–300. http://dx.doi.org/10.18231/j.jco.2024.044.

Full text
Abstract:
The aim of the study is to assess the feasibility of reusing copper nickel titanium wire and heat activated nickel titanium wires by evaluating the changes in efficiency and efficacy of wire after different sterilization techniques. 120 total samples were taken. 60 samples of Damon copper nickel titanium (ORMCOTM) and 60 samples of heat activated nickel titanium wires (ORMCOTM). Damon CuNiTi and HANT were divided in 4 different sub groups of 15 samples each. 15 as received wires served as controlled group. The remaining wires were placed intraorally for a period of 4 weeks in patients undergoi
APA, Harvard, Vancouver, ISO, and other styles
23

Novák, Pavel, Zdeněk Barták, Kateřina Nová, and Filip Průša. "Effect of Nickel and Titanium on Properties of Fe-Al-Si Alloy Prepared by Mechanical Alloying and Spark Plasma Sintering." Materials 13, no. 3 (2020): 800. http://dx.doi.org/10.3390/ma13030800.

Full text
Abstract:
This paper describes the structure and properties of an innovative Fe-Al-Si alloy with a reduced amount of silicon (5 wt. %) in order to avoid excessive brittleness. The alloy was produced by a combination of mechanical alloying and spark plasma sintering. Nickel and titanium were independently tested as the alloying elements for this alloy. It was found that wear resistance, which reached values comparable with tool steels, could be further improved by the addition of nickel. Nickel also improved the high-temperature oxidation behavior, because it lowers the liability of the oxide layers to s
APA, Harvard, Vancouver, ISO, and other styles
24

Chai, Guangquan, Ziyan Guo, Yingdi Wang, et al. "Effect of flushing temperature on preparation ability of rotary nickel-titanium files." Journal of Applied Biomaterials & Functional Materials 19 (January 2021): 228080002110147. http://dx.doi.org/10.1177/22808000211014724.

Full text
Abstract:
Purpose: The effect of flushing at different temperatures on the preparation ability of rotary nickel-titanium files was investigated to provide guideline for clinical application. Methods: Sixty ProTaper Universal F1 rotary nickel-titanium files were randomly divided into three groups treated by flushing at 6°C, 23°C, and 40°C. Root canal preparation was conducted by step-by-step method on standardized nickel-titanium instrument fracture models. During preparation, the thrust force was set as 10 N, and water was continuously flushed. The motor speed was 350 rpm (rounds per minute), and the to
APA, Harvard, Vancouver, ISO, and other styles
25

da Silva Vieira, Bruno, Rodrigo H. Cançado, Karina M. S. Freitas, Fabrício P. Valarelli, Renata C. Gobbi, and Ricardo C. Gobbi de Oliveira. "Effect of Clinical Use and Sterilization Process on the Transition Temperature Range of Thermally NiTi Alloys." Open Dentistry Journal 13, no. 1 (2019): 261–66. http://dx.doi.org/10.2174/1874210601913010261.

Full text
Abstract:
Background: Thermally activated nickel-titanium wires have been widely used by orthodontists due to more constant forces, generation over longer activation spans, greater resistance to permanent deformation, superelasticity characteristics when cyclically loaded, better spring-back and less hysteresis. Objective: The purpose of this study was to evaluate the influence of clinical use and sterilization process on the Transition Temperature Range (TTR) of thermoset nickel-titanium wires using Differential Scanning Calorimetry (DSC). Methods: Sections from four nickel-titanium wires (0.019 × 0.02
APA, Harvard, Vancouver, ISO, and other styles
26

Thakur, Digvijay B., R. M. Tiggelaar, K. Seshan, J. G. E. Gardeniers, and L. Lefferts. "Synthesis of Carbon Nanofibers as Support Layer for Metal Catalyst in a Microreactor for Three-Phase Reactions." Advances in Science and Technology 54 (September 2008): 231–36. http://dx.doi.org/10.4028/www.scientific.net/ast.54.231.

Full text
Abstract:
Carbon Nanofibers (CNF) layers were synthesized nickel-based thin-films on flat fused silica substrates. CNF synthesis was performed via thermal catalytic chemical vapor deposition of ethylene using nickel as metal catalyst. Different underlayer metal thin films, viz. titanium, tantalum and titanium-tungsten were tested in order to obtain stable and well-attached CNF films on fused silica substrates. It is found in case of titanium CNFs are formed on the nickel, but due to severe Ni/Ti inderdiffusion the titanium film looses its adhesive function, as a consequence of which the formed CNF film
APA, Harvard, Vancouver, ISO, and other styles
27

Testani, Claudio, and Mario Tului. "Improved Performance in Aerospace Structures with Ti and Ni Metal Matrix Composites." Materials Science Forum 706-709 (January 2012): 240–45. http://dx.doi.org/10.4028/www.scientific.net/msf.706-709.240.

Full text
Abstract:
The external structures of supersonic vehicles are exposed in several critical regions to temperatures that could reach 1000°C. This limit is higher than any safe operative service not only for titanium alloys but also for commercial nickel superalloys. The simplest way to improve titanium and nickel matrices temperature behavior (i.e: strength and fatigue resistance) is to introduce a strengthening phase in its matrix. These class of materials are known as: Metal Matrix Composites (MMC). It is possible reinforce both titanium and nickel superalloys by mean of high temperature resistant cerami
APA, Harvard, Vancouver, ISO, and other styles
28

Koval', A. V. "Investigation of Corrosion Behavior of Coatings Obtained on Steel by Electrospark Alloying with Manual Vibrator of Increased Frequency." Электронная обработка материалов 1, no. 57 (2021): 44–51. https://doi.org/10.5281/zenodo.4455859.

Full text
Abstract:
The comparative corrosion resistance in acidic, alkaline, and neutral environments of pure metals (steel, nickel, titanium), and of electrospark-alloyed coverings from nickel and titanium received on steel at high-frequency electrospark alloying is investigated. It is established that the phase structure, roughness, and porosity of the received coverings depend on the material of an electrode and on the modes of coatings deposition affect the corrosion behavior. A positive influence of high-frequency alloying with nickel and titanium on an increase in the corrosion resistance of a steel s
APA, Harvard, Vancouver, ISO, and other styles
29

Muralimohan, C. H., and V. Muthupandi. "Friction Welding of Type 304 Stainless Steel to CP Titanium Using Nickel Interlayer." Advanced Materials Research 794 (September 2013): 351–57. http://dx.doi.org/10.4028/www.scientific.net/amr.794.351.

Full text
Abstract:
Dissimilar metal joints of stainless steel to titanium find extensive industrial applications especially in the nuclear industry. However, it is well known that fusion welding of stainless steel to titanium is difficult because of the formation of brittle intermetallic compounds and the associated problems. To avoid this, welding processes or techniques with high reliability and productivity for these dissimilar materials are demanded. In the present work, joints comprising of 304 stainless steel and commercially pure titanium were produced by friction welding using nickel as interlayer. Inves
APA, Harvard, Vancouver, ISO, and other styles
30

Tanabe, Ikuo, Ye Htut Soe, Tetsuro Iyama, and Mitsuaki Shibuyta. "Development of Cutting Technology in Strong Alkaline Water." Key Engineering Materials 581 (October 2013): 272–77. http://dx.doi.org/10.4028/www.scientific.net/kem.581.272.

Full text
Abstract:
Recently titanium and nickel alloys have become eminent for making aeronautic and astronautic parts. Since both titanium and nickel alloys have very low thermal conductivity, the tool will be suffered from a huge damage by the generated heat during machining process. It is required for a durable tool with excellent cooling capacity. Therefore, in this research, cutting technology in strong alkaline water for machining of titanium and nickel alloys was developed and evaluated. Before cutting experiment, the corrosion resistance for titanium alloy and other materials were investigated. Then this
APA, Harvard, Vancouver, ISO, and other styles
31

Deng, L., K. Zhang, M. Lin, et al. "Influence of titanium carbide and titanium diboride on microstructure and mechanical properties of laser metal deposition nickel‐titanium alloys." Materialwissenschaft und Werkstofftechnik 55, no. 4 (2024): 437–42. http://dx.doi.org/10.1002/mawe.202300258.

Full text
Abstract:
AbstractNickel‐titanium alloys are produced via laser metal deposition using titanium carbide and titanium diboride as nucleating agents to refine the grain structure. The optimal process parameters are determined by analyzing the quality of the alloy formation. X‐ray diffraction confirms the simultaneous presence of the B19′ martensitic phase and B2 austenitic phase in the nickel‐titanium alloy fabricated by laser metal deposition. Tensile testing is performed on the samples at room temperature. The results show that adding mass fractions 0.9 % titanium carbide and titanium diboride effective
APA, Harvard, Vancouver, ISO, and other styles
32

Liu, Wen, Qiu Ping Ma, Jing Yan Guo, Bao Cheng Wang, and Qing Sen Meng. "The Comparison Research of Two Working Electrodes in Electrochemical Reduction of Silicon Tetrachloride." Advanced Materials Research 97-101 (March 2010): 32–35. http://dx.doi.org/10.4028/www.scientific.net/amr.97-101.32.

Full text
Abstract:
Silicon was electrodeposited by electrochemical reduction of silicon tetrachloride in propylene carbonate solvent on an alloy of nickel-titanium-niobium and nickel, which were used as working electrodes respectively. The effect of two substrates as working electrodes on the electrodeposition ability of the silicon was investigated by scanning electron microscopy (SEM) and energy dispersion spectroscopy (EDS). Results show that using an alloy of titanium, nickel and niobium as working electrode is better than nickel in the morphology and deposition yield of silicon.
APA, Harvard, Vancouver, ISO, and other styles
33

Maletta, Carmine, Luigino Filice, and Franco Furgiuele. "NiTi Belleville washers: Design, manufacturing and testing." Journal of Intelligent Material Systems and Structures 24, no. 6 (2012): 695–703. http://dx.doi.org/10.1177/1045389x12444490.

Full text
Abstract:
The thermomechanical properties of nickel–titanium-based Belleville washers have been analyzed in this investigation, together with their unusual mechanical and functional features, which can be attributed to the reversible phase transformation mechanisms of nickel–titanium alloys. In particular, numerical simulations have been carried out for a preliminary design of the Belleville washer, using a commercial finite element software and a special constitutive model for shape memory alloys. Subsequently, Belleville washers have been manufactured from a commercial pseudoelastic nickel–titanium al
APA, Harvard, Vancouver, ISO, and other styles
34

Popović, Jelena, Goran Radenković, Jovanka Gašić, et al. "Ultrastructural Analysis of the Surface of Endodontic Instruments after Immersion in Irrigating Solutions." Stomatoloski glasnik Srbije 62, no. 4 (2015): 157–65. http://dx.doi.org/10.1515/sdj-2015-0016.

Full text
Abstract:
Summary Introduction Separation (fracture) of endodontic instruments in the root canal during chemomechanical instrumentation is a complication that can compromise the final outcome of endodontic treatment. One of the most common factors that cause fatigue of endodontic instruments and consequent fracture is surface corrosion. The aim of this study was to investigate the ultrastructure of surface corrosion of endodontic instruments made of stainless steel and nickel-titanium after immersion in the most commonly used root canal irrigants. Material and Methods The study included 48 nickel-titani
APA, Harvard, Vancouver, ISO, and other styles
35

Zhou, Hui Min, Qing Fen Li, Yu Feng Zheng, and Li Li. "Fatigue Behavior of Ni-Ti Alloy Endodontic Files under Ultrasonic Unconstrained Condition." Key Engineering Materials 417-418 (October 2009): 77–80. http://dx.doi.org/10.4028/www.scientific.net/kem.417-418.77.

Full text
Abstract:
Nickel-titanium alloy are extensively used in engineering and biomedical fields for their excellent properties of shape-memory, super-elasticity and biocompatibility. Their fatigue performance has been attracted increasingly attention, because they are often used under cyclic conditions. In this paper, the ultrasonic fatigue behavior of nickel-titanium endodontic files under unconstrained condition has been studied using the self-designed ultrasonic fatigue testing equipment. The vibration and harmonious response properties of nickel-titanium endodontic files are also analyzed using finite ele
APA, Harvard, Vancouver, ISO, and other styles
36

Semenova, E. L., N. Yu Rusetskaya, V. M. Petyukh, and V. Ye Listovnichiy. "Ruthenium Effect on the Transformation in Equiatomic Titanium-Nickel Alloy." Platinum Metals Review 39, no. 4 (1995): 174–79. http://dx.doi.org/10.1595/003214095x394174179.

Full text
Abstract:
Martensitic transformations in equiatomic titanium-nickel and titaniumnickel based alloys are of interest because they are associated with the shape memory effect. Equiatomic titanium-nickel, which possesses such superior mechanical properties as high strength, elevated ductility and corrosion resistance, is the most important of several shape memory alloys. Here, the character of the martensitic transformalion in equiatomic titanium-nickel alloy with some of the nickel replaced by ruthenium is discussed. Data are presented on the temperature of the transformation upon heating and cooling, the
APA, Harvard, Vancouver, ISO, and other styles
37

Ren, Jia Long, Chun Yan Zhang, Qing Wang, Bo Wang, and Li Gang Zhao. "Cutting Performance of Hard Processing Materials Based on the DEFORM-3D." Advanced Materials Research 500 (April 2012): 8–12. http://dx.doi.org/10.4028/www.scientific.net/amr.500.8.

Full text
Abstract:
Based on the 3D finite element simulation software DEFORM-3D V6.1, the cutting process of three kinds of typical hard processing materials (titanium alloy, nickel alloy, stainless steel materials) were simulated. Main cutting force and cutting temperature of above materials were observed at different cutting parameters and cutting performance was studied. Results show that: under the same conditions, the main cutting force of nickel alloy IN718 was maximum, followed by TI-6AL-4V titanium alloy, stainless steel AISI-316h was minimum; the cutting temperature of nickel alloy IN718 was the highest
APA, Harvard, Vancouver, ISO, and other styles
38

Cherepanova, T. V. "APPLICATION OF MODIFIED NICKELIDE TITANIUM IMPLANTS TO REPLACE ABDOMINAL WII DEFECTS IN EXPERIMENT." Bulletin of the Russian Military Medical Academy 21, no. 1 (2019): 129–32. http://dx.doi.org/10.17816/brmma13065.

Full text
Abstract:
An important step towards the development of reticular endorotesis was the introduction and use of modern super-elastic material based on nickel-titanium. The article is devoted to a new way to solve one of the urgent problems of surgery. The experiment proved the possibility of an intraperitoneal method of disposing of a nickel-mesh titanium implant based on titanium nickelide modified by auto-coupling tissue in artificially created defects of the anterior abdominal wall, and anti-adhesive properties of the combined mesh material are shown. In the experiment, performed a series of experiments
APA, Harvard, Vancouver, ISO, and other styles
39

Ковтунов, А. И., Ю. Ю. Хохлов, Ю. А. Исаков та Л. В. Вершинин. "ФОРМИРОВАНИЕ ИНТЕРМЕТАЛЛИДНОГО СЛОЯ ПРИ ДИФФУЗИОННОМ ОТЖИГЕ ТИТАНА С НИКЕЛЕВЫМ ПОКРЫТИЕМ". Metallurg, № 2-2025 (25 лютого 2025): 74–78. https://doi.org/10.52351/00260827_2025_2_74.

Full text
Abstract:
Повышение срока эксплуатации и расширение области применения изделий из титана и титановых сплавов может быть достигнуто путем формирования функциональных покрытий на их поверхности. В качестве таких покрытий могут успешно применяться никелиды титана, которые отличаются особыми трибологическими свойствами, высокой демпфирующей способностью и коррозионно-эрозионной стойкостью. Простым и производительным способом получения интерметаллидных сплавов системы титан–никель на поверхности изделий из титана является технология, основанная на диффузионном отжиге титана с никелевым покрытием, при которой
APA, Harvard, Vancouver, ISO, and other styles
40

Dickson, T. Ryan, B. Moore, and N. Toyama. "Innovations: Laser-Cutting Nickel-Titanium." Materials Science Forum 394-395 (May 2002): 309–12. http://dx.doi.org/10.4028/www.scientific.net/msf.394-395.309.

Full text
APA, Harvard, Vancouver, ISO, and other styles
41

Ryan, Adam. "Superelastic Nickel Titanium Coil Springs." British Journal of Orthodontics 22, no. 4 (1995): 370–76. http://dx.doi.org/10.1179/bjo.22.4.370.

Full text
APA, Harvard, Vancouver, ISO, and other styles
42

Baumann, Michael A. "Nickel–titanium: options and challenges." Dental Clinics of North America 48, no. 1 (2004): 55–67. http://dx.doi.org/10.1016/j.cden.2003.11.001.

Full text
APA, Harvard, Vancouver, ISO, and other styles
43

Sharma, Neeraj, KamalKumar Jangra, and Tilak Raj. "Applications of Nickel-Titanium Alloy." Journal of Engineering and Technology 5, no. 1 (2015): 1. http://dx.doi.org/10.4103/0976-8580.149472.

Full text
APA, Harvard, Vancouver, ISO, and other styles
44

Savinykh, Leonid M., Tatyana A. Dudorova, Stanislav Yu Pomyalov, and Tatyana V. Kornyusheva. "THERMODYNAMIC ANALYSIS OF THE SYSTEMS: FERRUM-NICKEL-TITANIUM-NITROGEN AND NICKEL-CHROME-TITANIUM-NITROGEN." Vestnik Kurganskoi GSKhA, no. 3 (2022): 64–70. http://dx.doi.org/10.52463/22274227_2022_43_64.

Full text
APA, Harvard, Vancouver, ISO, and other styles
45

Fadeeva, I. V., O. V. Prokopova, E. V. Volchkova, et al. "Heterometallic (Nickel, Titanium)-dimethylglyoximates as precursors for nickel titanate coating." Perspektivnye Materialy 8 (2023): 57–67. http://dx.doi.org/10.30791/1028-978x-2023-8-57-67.

Full text
Abstract:
Heterometallic (nickel, titanium) dimethylglyoximate (II) with a nickel:titanium ratio of 1, was synthesized. based on nickel dimethylglyoximate (I) and titanium tetrachloride TiCl4 in chloroform The obtained complex II was characterized by XRD, IR and EPR spectroscopy, and elemental analysis. It was shown that the synthesized complex II is a solvate. On the basis of the analysis results, an assumption was made about the possible structure of complex II. It was found that the thermal decomposition of complex II starts at 44 °C. A constant mass of the decomposition product is observed in the te
APA, Harvard, Vancouver, ISO, and other styles
46

Divinski, Sergiy V., Ivo Stloukal, Lubomir Kral, and Christian Herzig. "Diffusion of Titanium and Nickel in B2 NiTi." Defect and Diffusion Forum 289-292 (April 2009): 377–82. http://dx.doi.org/10.4028/www.scientific.net/ddf.289-292.377.

Full text
Abstract:
Diffusion of both titanium and nickel was measured in the near stoichiometric Ni-49.4at.%Ti alloy with the B2 ordered structure. The radiotracer technique and the 44Ti and 63Ni isotopes were applied in the temperature interval from 900 to 1300 K. The penetration profiles were determined by precision parallel grinding or by ion beam sputtering at larger and smaller penetration depths, respectively. Titanium and nickel diffusivities were found to follow linear Arrhenius dependencies with the pre-exponential factors of 2.710-7 and 4.710-9 m2/s and the activation enthalpies of 205 and 143 kJ/mol
APA, Harvard, Vancouver, ISO, and other styles
47

A. Nihal Ahamed, S. Senthilnathan, Deepa Lakshmi Nagarajan, Ebenezer Mani, S. Thirumalai, and Kadhiresan R. "In Vitro Evaluation of the Corrosion Resistance and Biocompatibility of Different Dental Implant Metals." Metallurgical and Materials Engineering 31, no. 3 (2025): 368–71. https://doi.org/10.63278/1386.

Full text
Abstract:
Objective: To evaluate the corrosion resistance and biocompatibility of different dental implant metals in vitro. METHODS: Six dental implant metals (titanium, titanium alloy, stainless steel, cobalt-chromium alloy, nickel-titanium alloy, and zirconium) were evaluated for corrosion resistance using electrochemical impedance spectroscopy and potentiodynamic polarization tests. Biocompatibility was assessed using cell culture tests with human osteoblast-like cells. RESULTS: Titanium and titanium alloy showed the highest corrosion resistance (10.2 ± 0.5 Ω/cm² and 9.5 ± 0.4 Ω/cm², respectively) an
APA, Harvard, Vancouver, ISO, and other styles
48

Shirokova, D. S., Z. S. Khabadze, D. V. Voskresenskaya, F. R. Ismailov, Z. M. Gasanova, and N. N. Fedotova. "The analysis of research methods and results on resistance of nickel-titanium endodontic instruments to torsion load: the systematic review." Endodontics Today 19, no. 4 (2021): 320–25. http://dx.doi.org/10.36377/1683-2981-2021-19-4-320-325.

Full text
Abstract:
Relevance. The objective of this study was to analyze current data concerning research methods and results on resistance of nickel-titanium endodontic instruments to torsion load in order to minimize complications of dental root canal treatment. The use of the nickel -titanium endodontic instruments is a special importance to ensure high-quality dental root canal treatment; it prevents the further contamination of the canals with microorganisms. However, these instruments can form a fracture under torsional load which leads to further complications.Aim. The analysis of research methods and res
APA, Harvard, Vancouver, ISO, and other styles
49

Efimova, Ksenia A., Gennady V. Galevskii, Victoria V. Rudneva, N. A. Kozyrev, and Eugenia G. Orshanskaya. "Nickel-Based Composition Coating with Titanium Nanoboride." Applied Mechanics and Materials 788 (August 2015): 75–81. http://dx.doi.org/10.4028/www.scientific.net/amm.788.75.

Full text
Abstract:
Conditions of electrodeposition, the structure and physical-mechanical properties (microhardness, base cohesion, internal stresses, corrosion currents) of nickel-based galvanic composition coatings with nano and micropowders of titanium boride are investigated. It is determined that electrocrystallization of nickel in the presence of boride nanoparticles leads to the formation of coatings with small-sized structural fragments, low porosity and increased physical-mechanical properties. Titanium nanoboride is simultaneously a component of the composition coating and an effective modifier of the
APA, Harvard, Vancouver, ISO, and other styles
50

Mohammed, Mohanad Ali, and Alan Issa Saleem. "Effect of air abrasive polishing on nickel release, stainless steel corrosion, and nickel-titanium archwires." Journal of Dental Research, Dental Clinics, Dental Prospects 17, no. 4 (2023): 227–34. http://dx.doi.org/10.34172/joddd.2023.40536.

Full text
Abstract:
Background. Orthodontic treatment is becoming more and more popular. However, using fixed orthodontic devices for treatment affects oral hygiene and raises the risk of corrosion, plaque-related illnesses, and dental discoloration-related issues. Air abrasive polishing has a superior effect over the conventional method in removing dental deposits. Using fixed orthodontic appliances affects oral hygiene and raises the risk of diseases caused by plaque, tooth discoloration, and corrosion, as well as corrosion by ions. This study evaluated the impact of air polishing on nickel ion release and corr
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!