To see the other types of publications on this topic, follow the link: Non-sinusoidal current.

Journal articles on the topic 'Non-sinusoidal current'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 journal articles for your research on the topic 'Non-sinusoidal current.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse journal articles on a wide variety of disciplines and organise your bibliography correctly.

1

Modi, H. O., V. Jagadeesh Kumar, and P. Sankaran. "An Optical Fibre Sensor for Non-sinusoidal Current." IETE Journal of Research 43, no. 1 (1997): 79–83. http://dx.doi.org/10.1080/03772063.1997.11415965.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Kourennyi, Eduard, Alexander Bulgakov, and Arkady Kolomytsev. "Methods for Evaluating the Influence of Non-Sinusidal Voltage on Capacitor Units in Power Supply Systems." Известия высших учебных заведений. Электромеханика 64, no. 2 (2021): 86–92. http://dx.doi.org/10.17213/0136-3360-2021-2-86-92.

Full text
Abstract:
The problems of evaluating the EMC for capacitor units (CU) in power supply systems are considered. The admissible value of the current non-sinusoidal component for the CU was found, it corresponds to the actual standards. The dynamic model of the «supply line – CU» circuit has been substantiated. An equivalent circuit is given. A non-sinusoidal signal is considered as the sum of a sinusoidal and non-sinusoidal component. As a non-sinusoidal component, a voltage pulse noise model with oppositely polar periodic rectangular pulses and pauses was used. Two approaches to determine the useful signa
APA, Harvard, Vancouver, ISO, and other styles
3

Ebadi, M. R. "Estimation of Transformer Inrush Current using Non-Sinusoidal Harmonics." Physics and Technical Sciences 1, no. 1 (2013): 1. http://dx.doi.org/10.12966/pts.03.01.2013.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Butvin, P., B. Butvinová, O. V. Nielsen, and P. Brauer. "Converter for measurement of non-sinusoidal current peak value." Sensors and Actuators A: Physical 59, no. 1-3 (1997): 266–68. http://dx.doi.org/10.1016/s0924-4247(97)80186-0.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Rudevich, N. V. "Current transformers are in regimes of non-sinusoidal signals." Science and Transport Progress, no. 37 (June 25, 2011): 105–8. http://dx.doi.org/10.15802/stp2011/9443.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Kashif, Muhammad, Muhammad kamran Liaquat Bhatti, Waqar Tahir, Muhammad Usman Iqbal, Muhammad Usman, and Safdar Raza. "Harmonics Detection and its Mitigation in a Doubly Fed Induction Generator based Power System." Pakistan Journal of Engineering and Technology 3, no. 2 (2020): 189–93. http://dx.doi.org/10.51846/vol3iss2pp189-193.

Full text
Abstract:
Ideally, electric supplying companies are projected to convey sinusoidal voltage having the frequency of constant rate, while the consumers are expected to extract the current in sinusoidal forms with power factor nearly equal to unity. But extensive applications of equipment causing the production of harmonics in domestics and industrial appliances causes some problems in the smooth flow of current and voltage. Especially the usage of non-linear loads is causing the distortion of electric voltage and currents in the power system. Due to these non-sinusoidal flows of voltage and current (harmo
APA, Harvard, Vancouver, ISO, and other styles
7

Hartungi, Rusdy. "Investigation of The impact of Unbalanced and Non-sinusoidal Supply Voltages on Converters." International Journal of Smart Grid and Sustainable Energy Technologies 2, no. 1 (2019): 73–78. http://dx.doi.org/10.36040/ijsgset.v2i1.218.

Full text
Abstract:
In this paper two input current modulation strategies for matrix converters are experimentally analyzed under two different supply conditions: sinusoidal unbalanced voltages and non-sinusoidal balanced voltages. Both strategies use the Space Vector Modulation (SVM) technique in order to control the matrix converter accordingly to the input and output constraints. Strategy A modulates the input currents keeping the corresponding space vector in phase with the input voltage vector. Strategy B operates in order to keep the input current vector in phase with the positive sequence fundamental compo
APA, Harvard, Vancouver, ISO, and other styles
8

Douine, B., J. Leveque, and A. Rezzoug. "AC loss measurements of a high critical temperature superconductor transporting sinusoidal or non-sinusoidal current." IEEE Transactions on Appiled Superconductivity 10, no. 1 (2000): 1489–92. http://dx.doi.org/10.1109/77.828523.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Kovalov, Viktor, and Iulya Kovalova. "Mechanical Power of Induction Motors with Non-sinusoidal Power Supply." Problems of the Regional Energetics, no. 2(66) (May 2025): 10–17. https://doi.org/10.52254/1857-0070.2025.2-66.02.

Full text
Abstract:
When induction motors are powered by solid-state voltage and frequency converters, the torque on the shaft is created by the first harmonic of the current, and the higher harmonics of the cur-rent only create losses in the stator winding. The purpose of the work is to develop a methodolo-gy for determining the permissible mechanical load of asynchronous motors at non-sinusoidal currents. To achieve this goal, it is necessary to determine the influence on the mechanical pow-er of the motor of higher current harmonics, the effective values of which depend on the control parameters of semiconduct
APA, Harvard, Vancouver, ISO, and other styles
10

Romeo, F., and R. De Luca. "Effective non-sinusoidal current-phase dependence in conventional d.c. SQUIDs." Physics Letters A 328, no. 4-5 (2004): 330–34. http://dx.doi.org/10.1016/j.physleta.2004.06.061.

Full text
APA, Harvard, Vancouver, ISO, and other styles
11

Karimjonov, D. D., I. X. Siddikov, S. S. Azamov, and R. Uzakov. "Study on determination of an asynchronous motor’s reactive power by the current-to-voltage converter." IOP Conference Series: Earth and Environmental Science 1142, no. 1 (2023): 012023. http://dx.doi.org/10.1088/1755-1315/1142/1/012023.

Full text
Abstract:
Abstract This article presents a method for determining the primary currents, non-sinusoidal and asymmetrical currents flowing through the stator windings of an asynchronous motor based on the signal in the form of the output voltage from the current converter loops placed in each phase between the poles of the asynchronous motor stator and in the arrangement of the stator windings. Differences and characteristics of output signals are researched based on independent, series and opposite (bifilar) connection schemes of asynchronous motor current converter loops of measuring coil. In order to d
APA, Harvard, Vancouver, ISO, and other styles
12

Timsi and Dr Naresh Kumar Yadav. "Harmonics Distortion in Distribution Systems: A Review of Non–Linear Load Effects and Solutions." International Journal of Enhanced Research In Science Technology & Engineering 13, no. 08 (2024): 90–95. http://dx.doi.org/10.55948/ijerste.2024.0810.

Full text
Abstract:
Alinear load shows current corresponding to the applied voltage, while a "non-linear" load has varying impedance with voltage, prompting non-sinusoidal current in any event when associated with sinusoidal voltage. Harmonic current in non-sinusoidal current blends in with power distribution framework impedance, causing voltage distortion affecting both the framework and associated loads. Expanded utilization of power electronics and time-changing nonlinear loads in industry prompts serious electrical cable contamination, corrupting power supply quality, and effectiveness, and causing overheatin
APA, Harvard, Vancouver, ISO, and other styles
13

Nalina, B. S., and V. J. Vijayalakshmi. "Comparison of Current Control Strategies of Shunt Active Power Filter ." Applied Mechanics and Materials 573 (June 2014): 59–65. http://dx.doi.org/10.4028/www.scientific.net/amm.573.59.

Full text
Abstract:
Nowadays the number of non linear loads in power systems is increasing dramatically. These non linear loads inject harmonic currents and voltage which makes the supply currents non-sinusoidal. These harmonics are eliminated via an active power filter. The reference currents are generated by shunt active filter which is provided to compensate harmonic currents demanded by the load. Different current control strategies are implemented to improve the performance of shunt active power filter. These techniques are useful in making the supply currents sinusoidal. The performance of the current contr
APA, Harvard, Vancouver, ISO, and other styles
14

Zhou, Yang, and Xiao Ma. "Non-Sinusoidal Injection Control Strategy of Z-Source Inverter." Advanced Materials Research 591-593 (November 2012): 1360–66. http://dx.doi.org/10.4028/www.scientific.net/amr.591-593.1360.

Full text
Abstract:
The modulation strategy of injecting non-sinusoidal into reference voltage is presented in this paper. Z-source inductor current ripple and the relationship of voltage gain versus modulation index are analyzed in detail. Compared to simple boost control, the non-sinusoidal injection modulation strategy can obviously decreased the switching times, thus switching loss is cut down, and the voltage stress and Z-source inductor current ripple are obviously reduced. Theoretical analysis, simulation and experimental results are presented to demonstrate the features of the control.
APA, Harvard, Vancouver, ISO, and other styles
15

Kumar, Y. Anil, P. Swathi, Vajjala Venkata, Anjali Prasanna, G. Veera Sankara Reddy, and Sareddy Venkata Rami Reddy. "Improved Harmonic Mitigation Using Dual Three-Phase iUPQC." E3S Web of Conferences 616 (2025): 02016. https://doi.org/10.1051/e3sconf/202561602016.

Full text
Abstract:
This study simplifies iUPQC administration by employing a dual three-phase design, which makes the methodology behind the study more transparent. By utilising a parallel (shunt) and series active filter, it is possible to limit the amount of harmonics and unbalances produced by the iUPQC. When compared to a conventional UPQC, an iUPQC modifies the series filter in such a way that it operates as a sinusoidal current source. This is in contrast to a conventional UPQC. Since the iUPQC is regulated using voltage and current sinusoidal references rather than non-sinusoidal references, the frequency
APA, Harvard, Vancouver, ISO, and other styles
16

Kovernikova, L. I., and Ngoc Hung Bui. "Additional Power Losses Under Non-Sinusoidal Conditions in a 22 kV Overhead Power Line." Energy Systems Research 7, no. 1(25) (2024): 31–36. http://dx.doi.org/10.25729/esr.2024.01.0003.

Full text
Abstract:
Non-sinusoidal conditions in the electrical networks cause active power losses at the fundamental frequency, corresponding to the first harmonic, and at harmonic frequencies, which are a multiple of the fundamental frequency. Non-sinusoidal currents flow through network components and create additional active power losses. One of the non-sinusoidal current sources is electronic equipment used in industrial plants to control process equipment. In Vietnam, coal mines use frequency-controlled induction motors when processing coal. The induction motors consume non-sinusoidal current, which creates
APA, Harvard, Vancouver, ISO, and other styles
17

Bisariya, Shailendra, and Neelofer Afzal. "Electronically Tunable Sinusoidal Oscillator Using Only Single Current-Controlled Current Conveyor Trans-Conductance Amplifier." International Journal of Electrical and Electronics Research 12, no. 1 (2024): 119–25. http://dx.doi.org/10.37391/ijeer.120117.

Full text
Abstract:
This work presents a wide frequency range sinusoidal oscillator design that relies on only one active component, a current-controlled current conveyor trans-conductance amplifier, and a few passive components. It just employs two grounded and non-floating capacitors and one resistor to complete the procedure. This design has the advantage of allowing the oscillation frequency and condition to be adjusted not only electronically, but also separately, without affecting the values of any passive components. To verify the functionality and usefulness of the developed sinusoidal oscillator circuit,
APA, Harvard, Vancouver, ISO, and other styles
18

Wong, H. M., and S. Y. Goh. "Experimental comparison of sinusoidal motion and non-sinusoidal motion of rise-dwell-fall-dwell in a Stirling engine." Journal of Mechanical Engineering and Sciences 14, no. 3 (2020): 6971–81. http://dx.doi.org/10.15282/jmes.14.3.2020.01.0546.

Full text
Abstract:
The Stirling engine is deemed to play a role in the near future of power generation. However, there is a large performance difference between the real and ideal Stirling engine. The use of sinusoidal motion for both displacer and piston in current applications is one of the reasons for this difference as it limits heat transfer. This paper investigated the use of non-sinusoidal rise-dwell-fall-dwell (RDFD) motion on both displacer and piston to improve the performance of a real Stirling engine and compared it to the conventional sinusoidal motion crankshaft driven Stirling engine. A gamma conf
APA, Harvard, Vancouver, ISO, and other styles
19

Voronina, Ekaterina. "MODELING OF NON-SINUSOIDAL MODES OF TRACTION POWER SUPPLY SYSTEMS WITH DETERMINATION OF FORMS OF CURRENTS, VOLTAGES AND INSTANT POWERS." Modern Technologies and Scientific and Technological Progress 2023, no. 1 (2023): 194–95. http://dx.doi.org/10.36629/2686-9896-2023-1-194-195.

Full text
APA, Harvard, Vancouver, ISO, and other styles
20

Savenko, O. S. "Hybrid VAR compensator operating study under conditions of a three-wire network." Reporter of the Priazovskyi State Technical University. Section: Technical sciences, no. 45 (December 29, 2022): 73–80. http://dx.doi.org/10.31498/2225-6733.45.2022.276239.

Full text
Abstract:
The approaches to the control of the hybrid VAR compensator are considered. A hybrid VAR compensator is a passive and active compensator connected in series. The passive part is represented by a thyristor-switched capacitor bank. The power part of the active part is implemented on the basis of an autonomous voltage inverter, connected through a voltage transformer in series with a passive part. Most of the reactive power is compensated by means of the compensator’s passive part. The hybrid compensator combines the advantages of passive (low price, reliability) and active compensators (possibil
APA, Harvard, Vancouver, ISO, and other styles
21

Montoya, Francisco G., Raúl Baños, Alfredo Alcayde, Francisco Manuel Arrabal-Campos, and Javier Roldán Pérez. "Geometric Algebra Framework Applied to Symmetrical Balanced Three-Phase Systems for Sinusoidal and Non-Sinusoidal Voltage Supply." Mathematics 9, no. 11 (2021): 1259. http://dx.doi.org/10.3390/math9111259.

Full text
Abstract:
This paper presents a new framework based on geometric algebra (GA) to solve and analyse three-phase balanced electrical circuits under sinusoidal and non-sinusoidal conditions. The proposed approach is an exploratory application of the geometric algebra power theory (GAPoT) to multiple-phase systems. A definition of geometric apparent power for three-phase systems, that complies with the energy conservation principle, is also introduced. Power calculations are performed in a multi-dimensional Euclidean space where cross effects between voltage and current harmonics are taken into consideratio
APA, Harvard, Vancouver, ISO, and other styles
22

SLOMOVITZ, DANIEL. "Behaviour of power-factor meters under non-sinusoidal current and voltage." International Journal of Electronics 70, no. 4 (1991): 827–38. http://dx.doi.org/10.1080/00207219108921331.

Full text
APA, Harvard, Vancouver, ISO, and other styles
23

Kornev, V. K., T. Y. Karminskaya, Y. V. Kislinskii, P. V. Komissinki, K. Y. Constantinian, and G. A. Ovsyannikov. "Dynamics of underdamped Josephson junctions with non-sinusoidal current-phase relation." Physica C: Superconductivity and its Applications 435, no. 1-2 (2006): 27–30. http://dx.doi.org/10.1016/j.physc.2006.01.012.

Full text
APA, Harvard, Vancouver, ISO, and other styles
24

Faiz, Jawad, Milad Ghazizadeh, and Hashem Oraee. "Derating of transformers under non‐linear load current and non‐sinusoidal voltage – an overview." IET Electric Power Applications 9, no. 7 (2015): 486–95. http://dx.doi.org/10.1049/iet-epa.2014.0377.

Full text
APA, Harvard, Vancouver, ISO, and other styles
25

Alyozbaky, Omar Sharaf Al-deen, and Mohd Zainal Abidin Ab‐Kadir. "Influence of non-sinusoidal power supply on the performance of a single-phase capacitor induction motor." Indonesian Journal of Electrical Engineering and Computer Science 25, no. 3 (2022): 1246. http://dx.doi.org/10.11591/ijeecs.v25.i3.pp1246-1257.

Full text
Abstract:
<span>Harmonic is seen to be an important factor that can influence the performance of different electrical appliances. Earlier studies have regarded the non-sinusoidal power supply as the major source of the harmonic in the induction motors. In this paper, the researcher compared the results generated by a single-phase capacitor induction motor (SIM) using the sinusoidal and non-sinusoidal power supplies. The results in the study could help in comprehensively understanding the impact of the harmonic on the effective performance of the SIM machines when they were powered using a non-sinu
APA, Harvard, Vancouver, ISO, and other styles
26

Kovalova, Yuliia, Victor Kovalov, and Irina Shcherbak. "Reactive Power of Asynchronous Electric Drives with Semiconductor Converters." Lighting engineering and power engineering 60, no. 1 (2021): 9–14. http://dx.doi.org/10.33042/2079-424x.2021.60.1.02.

Full text
Abstract:
The purpose of the article is to obtain a ratio for determining the reactive power of induction motors when powered by semiconductor converters. The task is to determine the dependence of reactive power on control parameters of the converters. The research method used is computer simulation of electric drive based on Fryze power theory for non-sinusoidal currents. The result is the obtained expression for the calculation of reactive power, which takes into account the rated idle current of the motor with sinusoidal power supply and the type of converter, due to introducing special coefficients
APA, Harvard, Vancouver, ISO, and other styles
27

Mini, Youssouf, Ngac Ky Nguyen, Eric Semail, and Duc Tan Vu. "Enhancement of Sensorless Control for Non-Sinusoidal Multiphase Drives-Part I: Operation in Medium and High-Speed Range." Energies 15, no. 2 (2022): 607. http://dx.doi.org/10.3390/en15020607.

Full text
Abstract:
This two-part study proposes a new sensorless control strategy for non-sinusoidal multiphase permanent magnet synchronous machines (PMSMs), especially integrated motor drives (IMDs). Based on the Sliding Mode Observer (SMO), the proposed sensorless control strategy uses the signals (currents and voltages) of all fictitious machines of the multiphase PMSMs. It can estimate the high-accuracy rotor positions that are required in vector control. This proposed strategy is compared to the conventional sensorless control strategy that applies only current and voltage signals of the main fictitious ma
APA, Harvard, Vancouver, ISO, and other styles
28

Samikannu, Ravi, R. Rohini, V. Sampath Kumar, and Vitaliy Mezhuyev. "Design and Development of Shunt Active Filter Using MATLAB for Minimization of Harmonics." International Journal of Engineering & Technology 7, no. 3.10 (2018): 179. http://dx.doi.org/10.14419/ijet.v7i3.10.15655.

Full text
Abstract:
Nonlinear loads draw non sinusoidal current and voltage from the utility. These non-sinusoidal current and voltages created due to nonlinear loads are called harmonics. The harmonic voltage and current disturbs the system back and creates big power quality problem. Therefore in order to mitigate harmonic problems different mechanisms are used. In this work as introduction different power quality problems, harmonics and their mitigation techniques/filters are presented and discussed. Between the different ways to minimize/eliminate harmonics active power filters are most Prominent one. This res
APA, Harvard, Vancouver, ISO, and other styles
29

Onah, A.J., E.E. Ezema, and N.A. Uzodife. "Application of Active Filters in Power Systems." Nigerian Research Journal of Engineering and Environmental Sciences 6, no. 1 (2021): 370–86. https://doi.org/10.5281/zenodo.5048451.

Full text
Abstract:
<em>This paper is intended to show how current harmonics are generated by some nonlinear loads, and how these harmonics can be suppressed. Majority of loads such as induction motors, battery chargers, static converters, light fittings, arc furnaces, transformers, cables, and transmission lines draw both sinusoidal currents and currents which are multiples of the supply frequency, commonly called harmonics. These harmonics pollute the AC mains resulting in poor quality power supply, which is detrimental to many sensitive loads. This paper shows how an active filter (AF) can be used to filter th
APA, Harvard, Vancouver, ISO, and other styles
30

Silva, Sérgio Augusto Oliveira da, Pedro F. Donoso-Garcia, Porfírio C. Cortizo, and Paulo F. Seixas. "A line-interactive UPS system implementation with series-parallel active power-line conditioning for three-phase, four-wire systems." Sba: Controle & Automação Sociedade Brasileira de Automatica 16, no. 2 (2005): 200–210. http://dx.doi.org/10.1590/s0103-17592005000200008.

Full text
Abstract:
This paper presents a three-phase line-interactive uninterruptible power supply (UPS) system with active series-parallel power-line conditioning capabilities. Synchronous reference frame (SRF)-based controller is used for harmonic and reactive power compensation generated from any configuration of non-linear loads. Under normal line conditions the UPS system works with universal filtering capabilities, such as compensating the input currents and output voltages. Two three-phase pulsewidth modulation (PWM) converters, called series and parallel active filters, are used to perform the series and
APA, Harvard, Vancouver, ISO, and other styles
31

Sergeyev, Daulet. "Plasma Frequency in Josephson Junctions with a Non-Sinusoidal Current-Phase Relation." Solid State Phenomena 200 (April 2013): 272–75. http://dx.doi.org/10.4028/www.scientific.net/ssp.200.272.

Full text
Abstract:
In this article we consider the modulation of the plasma frequency switching current-phase dependence of Josephson systems based on the CuO2 harmonic mode into the anharmonic one. It is established the increase of the plasma frequency in the cuprate high-temperature superconductors arising due to deviation of dependence current-phase between the oxide planes in high-temperature superconductors from the standard sine wave form.
APA, Harvard, Vancouver, ISO, and other styles
32

Montoya, Francisco, Raul Baños, Alcayde, and Francisco Arrabal. "Analysis of power flow under non-sinusoidal conditions in the presence of harmonics and interharmonics using geometric algebra." International Journal of Electrical Power & Energy Systems 11 (October 1, 2019): 486–92. https://doi.org/10.1016/j.ijepes.2019.04.032.

Full text
Abstract:
The calculation of power flow in power systems with the presence of harmonics has been properly studied in the scientific literature. However, power flow calculation considering interharmonic components is still an open question. Traditional methods based on the IEEE1459 standard have proven to be valid and accurate only for linear and sinusoidal systems, but have been criticized for non-linear and non-sinusoidal systems because they are not able to explain correctly the current and voltage interactions beyond the active power. This paper proposes the use of a novel mathematical framework call
APA, Harvard, Vancouver, ISO, and other styles
33

Khmelnуtskyi, Evgen, and Oleg Klyuyev. "DETERMINATION OF ABNORMAL HARMONICS AND HARMONIC COMPOSITION COEFFICIENTS OF NON-SINUSOIDITY IN A 10 kV NETWORK WITH A VALVE ELECTRIC DRIVE OF DIRECT CURRENT." Collection of scholarly papers of Dniprovsk State Technical University (Technical Sciences) 1, no. (42) (2023): 128–33. http://dx.doi.org/10.31319/2519-2884.42.2023.15.

Full text
Abstract:
The operation process of the electric valve drive is accompanied by the generation of higher harmonics — canonical and non-canonical. Limitation of the level of canonical harmonics is carried out by power resonance filters, however, in the case of asymmetry of the control pulses of the thyristors of the converters, non-canonical harmonics are generated — both even and odd harmonics. The composition of non-canonical harmonics can be determined in the case of harmonic analysis of non-sinusoidal current and voltage coefficients. The conducted harmonic analysis makes it possible to determine the c
APA, Harvard, Vancouver, ISO, and other styles
34

Javed, Khalid, Lieven Vandevelde, and Frederik De Belie. "Analysis and Demonstration of Control Scheme for Multiple Operating Modes of Energy Storage Converters to Enhance Power Factor." Mathematics 10, no. 19 (2022): 3434. http://dx.doi.org/10.3390/math10193434.

Full text
Abstract:
Rectifiers are required by the devices connected to the distribution end of the electrical power networks for AC/DC conversion. The line current becomes non-sinusoidal when a capacitor with a significant value is used to mitigate the output voltage ripple. This type of converter emulates a non-resistive impedance to the grid, due to which a bend occurs in the shape of the line current, which results in high total harmonic distortion and a low power factor. For perceiving sinusoidal current, power factor correction techniques are required. A digital controller for parallel-connected buck-boost
APA, Harvard, Vancouver, ISO, and other styles
35

Montoya, Francisco, Raul Baños, Alfredo Alcayde, Francisco Arrabal, and Eduardo Viciana. "Analysis of non-active power in non-sinusoidal circuits using geometric algebra." International Journal of Electrical Power & Energy Systems 116 (September 8, 2019): 105541. https://doi.org/10.1016/j.ijepes.2019.105541.

Full text
Abstract:
A new approach for the definition of non-active power in electrical systems is presented in this paper. Through the use of geometric algebra, it is possible to define a new term called geometric non-active power, which is applicable to both sinusoidal and non-sinusoidal systems, and to both linear and nonlinear loads. The classic definitions of distortion and reactive power are compared and discussed in our proposal. We verify how geometric non-active power can appear in both purely resistive and purely reactive systems. The superiority of geometric algebra is revealed through several examples
APA, Harvard, Vancouver, ISO, and other styles
36

Rasoulpoor, Masoumeh, Mohammad Mirzaie, and Seyyed Mehdi Mirimani. "Effects of non-sinusoidal current on current division, ampacity and magnetic field of parallel power cables." IET Science, Measurement & Technology 11, no. 5 (2017): 553–62. http://dx.doi.org/10.1049/iet-smt.2016.0549.

Full text
APA, Harvard, Vancouver, ISO, and other styles
37

Schasny, V. P., and A. I. Zhukouski. "Electromagnetic Compatibility of Compensating Devices and Converters of an Adjustable Electric Drive in Electrical Networks of Industrial Enterprises." ENERGETIKA. Proceedings of CIS higher education institutions and power engineering associations 65, no. 1 (2022): 37–51. http://dx.doi.org/10.21122/1029-7448-2022-65-1-37-51.

Full text
Abstract:
The problems of reactive power compensation and improving the quality of electrical energy in the power supply systems of industrial enterprises are inseparable. Their relevance is due to the widespread use of electric receivers that consume reactive power and distort the quality of electrical energy in the network, as well as the implementation of new technologies, systems and equipment into production that make increased demands on the quality of electrical energy consumed. An important characteristic of the quality of electrical energy rationed by GOST 32144–2013 is the non-sinusoidal volta
APA, Harvard, Vancouver, ISO, and other styles
38

Vanin, Valery, Alexandr Bulychov, Maxim Popov, Olga Vasilyeva, and Maria Shakhova. "About influence of non-sinusoidal currents and voltages on the amount of the electric energy." MATEC Web of Conferences 245 (2018): 06009. http://dx.doi.org/10.1051/matecconf/201824506009.

Full text
Abstract:
The results of measurements of the harmonics components of the current, voltage, power of harmonics at the point of connection of electric receivers with a non-linear voltage-current characteristic are considered. It is shown that the amount of electric energy including the non-sinusoidality of the currents and voltages consumed by the non-linear load is less than the amount of the fundamental frequency energy. The difference between them is the harmonic distortion energy that causes extra losses to the electric networks. The voltage harmonic distortions at the measurement point exceed the nor
APA, Harvard, Vancouver, ISO, and other styles
39

Huang, Ming. "Submodule Capacitor Voltage Ripple Reduction of Full-Bridge Submodule-Based MMC (FBSM-MMC) with Non-Sinusoidal Voltage Injection." Energies 16, no. 11 (2023): 4305. http://dx.doi.org/10.3390/en16114305.

Full text
Abstract:
The full-bridge submodule (FBSM)-based modular multilevel converter (FBSM-MMC) offers promising performance due to its ability to output negative FBSM voltage. This paper studies this ability of the FBSM-MMC under zero-sequence voltage injection (ZSVI) and second-order harmonic current injection (SHCI). The focus of the research is to redistribute the FBSM powers by injecting an additional power degree of freedom, resulting in a smaller FBSM capacitor voltage ripple, while keeping the maximum AC output voltage for a given fundamental frequency component of the arm voltage reference. Accordingl
APA, Harvard, Vancouver, ISO, and other styles
40

Montoya, Francisco, Alfredo Alcayde, Francisco Arrabal-Campos, and Raul Baños. "Quadrature Current Compensation in Non-Sinusoidal Circuits Using Geometric Algebra and Evolutionary Algorithms." Energies 12, no. 4 (2019): 692. http://dx.doi.org/10.3390/en12040692.

Full text
Abstract:
Non-linear loads in circuits cause the appearance of harmonic disturbances both in voltage and current. In order to minimize the effects of these disturbances and, therefore, to control the flow of electricity between the source and the load, passive or active filters are often used. Nevertheless, determining the type of filter and the characteristics of their elements is not a trivial task. In fact, the development of algorithms for calculating the parameters of filters is still an open question. This paper analyzes the use of genetic algorithms to maximize the power factor compensation in no
APA, Harvard, Vancouver, ISO, and other styles
41

LAHOOTI ESHKEVARI, Alireza, and Hossein TORKAMAN. "Simplified model predictive current control of non-sinusoidal low power brushless DC machines." TURKISH JOURNAL OF ELECTRICAL ENGINEERING & COMPUTER SCIENCES 28, no. 4 (2020): 2288–302. http://dx.doi.org/10.3906/elk-2001-141.

Full text
APA, Harvard, Vancouver, ISO, and other styles
42

Pitaksuttayaprot, Koson, Kritphon Phanrattanachai, and Winai Jaikla. "Electronically Adjustable Multiphase Sinusoidal Oscillator with High-Output Impedance at Output Current Nodes Using VDCCs." Electronics 11, no. 19 (2022): 3227. http://dx.doi.org/10.3390/electronics11193227.

Full text
Abstract:
This paper presents the high-output-impedance current-mode multiphase sinusoidal oscillators (MSO) using voltage differencing current conveyor (VDCC)-based lossy integrators, which consist of one VDCC, one grounded capacitor, and two grounded resistors. The proposed oscillator can provide an odd-phase and even-phase system without the use of an additional amplifier. The frequency of oscillation (FO) is electronically tuned via the bias current without affecting the condition of oscillation (CO). The proposed oscillator is designed to obtain three-phase sinusoidal waveforms (n = 3). The effect
APA, Harvard, Vancouver, ISO, and other styles
43

Canova, Aldo, Michele Tartaglia, and Michele Quercio. "Optimisation Design of a Low-Frequency Eddy Current Rail Heater." Energies 16, no. 21 (2023): 7427. http://dx.doi.org/10.3390/en16217427.

Full text
Abstract:
The aim of the work is the optimisation of a rail heater, constituted by a magnetic core supplied by a sinusoidal current, which induces an eddy current in the rail. Optimisation parameters are electrical and geometrical quantities: supply frequency, voltage amplitude, airgaps, and core shape, while objectives are power transferred to the rail, absorbed current, and power distribution index. Optimisation is performed by an accurate field analysis, provided by the finite element method (FEM), coupled to an automated multiobjective procedure based on fuzzy logic. Particular care has been devoted
APA, Harvard, Vancouver, ISO, and other styles
44

Mekahlia, Abdelhak, Eric Semail, Franck Scuiller, and Hussein Zahr. "Reduced-Order Model of Rotor Cage in Multiphase Induction Machines: Application on the Prediction of Torque Pulsations." Mathematical and Computational Applications 25, no. 1 (2020): 11. http://dx.doi.org/10.3390/mca25010011.

Full text
Abstract:
For three-phase induction machines supplied by sinusoidal current, it is usual to model the n-bar squirrel-cage by an equivalent two-phase circuit. For a multiphase induction machine which can be supplied with different harmonics of current, the reduced-order model of the rotor must be more carefully chosen in order to predict the pulsations of torque. The proposed analysis allows to avoid a wrong design with non-sinusoidal magnetomotive forces. An analytical approach is proposed and confirmed by Finite-Element modelling at first for a three-phase induction machine and secondly for a five-phas
APA, Harvard, Vancouver, ISO, and other styles
45

Kim, Heonyoung, Yongsu Han, Kibok Lee, and Subhashish Bhattacharya. "A Sinusoidal Current Control Strategy Based on Harmonic Voltage Injection for Harmonic Loss Reduction of PMSMs With Non-Sinusoidal Back-EMF." IEEE Transactions on Industry Applications 56, no. 6 (2020): 7032–43. http://dx.doi.org/10.1109/tia.2020.3016210.

Full text
APA, Harvard, Vancouver, ISO, and other styles
46

Van Cuong, Ngo, and Lidiia I. Kovernikova. "Predicting the influence of the non-sinusoidal network mode on power transformers." E3S Web of Conferences 114 (2019): 04005. http://dx.doi.org/10.1051/e3sconf/201911404005.

Full text
Abstract:
The parameters of electrical network modes often do not meet the requirements of Russian GOST 32144-2013 and the guidelines of Vietnam. In the actual operating conditions while there is the non-sinusoidal mode in electrical networks voltage and current harmonics are present. Harmonics result in overheating and damage of power transformers since they cause additional active power losses. Additional losses lead to the additional heat release, accelerating the process of insulating paper, transformer oil and magnetic structure deterioration consequently shortening the service life of a power tran
APA, Harvard, Vancouver, ISO, and other styles
47

Jorge Rafael Gonzalez-Teodoro, Enrique Romero-Cadaval, Rafael Asensi, and Vladimir Kindl. "Equivalent Electrical Model of an Inductor Excited by a Triangular Current Including Saturation." Communications - Scientific letters of the University of Zilina 22, no. 3 (2020): 110–18. http://dx.doi.org/10.26552/com.c.2020.3.110-118.

Full text
Abstract:
A model for an equivalent electrical circuit designed for a ferrite (3C90) inductor usually used in power converters excited by a non-sinusoidal current appropriate for use in power electronics is proposed. This study, based on 3D finite element analysis, leads to significant precision advantages over 2D analysis for non-symmetric inductors. The frequency range of the analysis for the toroidal core was between 15 kHz and 1 GHz, with different levels of excitation in non-saturation and saturation status focusing on the power loss.
APA, Harvard, Vancouver, ISO, and other styles
48

Montoya, Francisco G., Raúl Baños, Alfredo Alcayde, Francisco M. Arrabal-Campos, and Javier Roldán-Pérez. "Geometric Algebra Applied to Multiphase Electrical Circuits in Mixed Time–Frequency Domain by Means of Hypercomplex Hilbert Transform." Mathematics 10, no. 9 (2022): 1419. http://dx.doi.org/10.3390/math10091419.

Full text
Abstract:
In this paper, power flows in electrical circuits are modelled in a mixed time-frequency domain by using geometric algebra and the Hilbert transform for the first time. The use of this mathematical framework overcomes some of the limitations of some of the existing methodologies, in which the so-called “active current” may not lead to the lowest Root Mean Square (RMS) current under distorted supply or unbalanced load. Moreover, this current may contain higher levels of harmonic distortion compared to the supply voltage. The proposed method can be used for sinusoidal and non-sinusoidal power su
APA, Harvard, Vancouver, ISO, and other styles
49

Bolaño Martínez, Adrián, Isaac Jimenez Navarro, Vladimir Sousa Santos, Enrique Ciro Quispe, and Pablo Daniel Donolo. "MATLAB/Simulink modeling of electric motors operating with harmonics and unbalance." International Journal of Electrical and Computer Engineering (IJECE) 12, no. 5 (2022): 4640. http://dx.doi.org/10.11591/ijece.v12i5.pp4640-4648.

Full text
Abstract:
This paper aims to present a simulation model for the analysis of the operational characteristics of electric motors (EMs). The model was developed on the Simulink platform of the MATLAB program and allows analysis in supply conditions with harmonics and voltage unbalance. The contribution of the model is that it considers the mechanical losses and provides for the study of the effect of each component of the electrical sequence of the harmonics and the voltage unbalance on the electromechanical characteristics of the EM. The model developed was tested in a 37.3 kW EM, operating under four pow
APA, Harvard, Vancouver, ISO, and other styles
50

Adrián, Bolaño Martínez, Jiménez Navarro Isaac, Sousa Santo Vladimir, Ciro Quispe Enrique, and Daniel Donolo Pablo. "MATLAB/Simulink modeling of electric motors operating with harmonics and unbalance." International Journal of Electrical and Computer Engineering (IJECE) 12, no. 5 (2022): 4640–48. https://doi.org/10.11591/ijece.v12i5.pp4640-4648.

Full text
Abstract:
This paper aims to present a simulation model for the analysis of the operational characteristics of electric motors (EMs). The model was developed on the Simulink platform of the MATLAB program and allows analysis in supply conditions with harmonics and voltage unbalance. The contribution of the model is that it considers the mechanical losses and provides for the study of the effect of each component of the electrical sequence of the harmonics and the voltage unbalance on the electromechanical characteristics of the EM. The model developed was tested in a 37.3 kW EM, operating under four pow
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!