Academic literature on the topic 'Non-splinted impressions'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Non-splinted impressions.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Non-splinted impressions"

1

International, Journal of Medical Science and Innovative Research (IJMSIR). "A Comparative Study to Evaluate The Accuracy of Open Tray Splinted and Non-Splinted Implant Level Impressions and Impressions Obtained From Two Intraoral Scanners For Three Implants Placed in A Partially Edentulous Arch - An in Vitro Study." International Journal of Medical Science and Innovative Research (IJMSIR) 9, no. 4 (2024): 185–97. https://doi.org/10.5281/zenodo.15422901.

Full text
Abstract:
<strong>Abstract</strong> Title: A comparative study to evaluate the accuracy of open tray splinted and non-splinted implant level impressions and impressions obtained from two intraoral scanners for three implants placed in a partially edentulous arch - an in vitro study <strong>Objective</strong>: The aim of this in vitro study was to compare and evaluate the accuracy of open tray splinted and non-splinted Implant level impression and impressions obtained from two intraoral scanners for three implants placed in a partially edentulous arch and to evaluate which of the two scanners used (Trios
APA, Harvard, Vancouver, ISO, and other styles
2

Rajput, Mansi, J. Baranikrishnan, Manawar A. Mansoor, Radhika Thakkar, Shivani Karre, and Jeetu Verma. "Evaluation of Dimensional Change in Different Elastomeric Impression Materials Used in Implants: An Original Research." Journal of Pharmacy and Bioallied Sciences 16, Suppl 1 (2024): S605—S608. http://dx.doi.org/10.4103/jpbs.jpbs_886_23.

Full text
Abstract:
ABSTRACT Aim: The study’s objective was to assess the dimensional accuracy of hybrid polyether and polyvinyl siloxane materials for implant impressions. Materials and Methods: Nine groups were created from 45 samples of various building materials and construction techniques from the study. Five samples were tested, and 45 impressions were recorded. Results: The hybrid non-splinted technique has improved implant site replication, accuracy, and low interimplant distance alterations. Conclusion: The finest possible reproduction of implant sites on the master cast was made feasible by the use of a
APA, Harvard, Vancouver, ISO, and other styles
3

Debajyoti Sarkar, Shitij Srivastava, Abhinav Shekhar, Amrita Jayaswal, Love Bhatia, and Anshuman Chaturvedi. "EVALUATION OF ACCURACY OF TWO DIFFERENT IMPRESSION MATERIALS AND THREE DIFFERENT IMPRESSION TECHNIQUES ON THE VERTICAL MISFIT OF A THREE UNIT IMPLANT SUPPORTED FIXED DENTURE PROSTHESES." UNIVERSITY JOURNAL OF DENTAL SCIENCES 6, no. 1 (2020): 15–20. http://dx.doi.org/10.21276/ujds.2020.6.1.6.

Full text
Abstract:
&#x0D; &#x0D; &#x0D; AIM: The aim of the study is to evaluate the accuracy of two different impression materials and three different impression techniques on the vertical misfit of a three-unit implant supported fixed denture prostheses.Materials and Methods: A total of 60 casts were fabricated for the present study with a closed tray, open tray and open tray splinted abutment impression technique. Two different commercially available impression materials were used - polyether and addition silicone. Both the materials were used for all the above impression techniques.Results: Accordingtotheres
APA, Harvard, Vancouver, ISO, and other styles
4

Shetty, Pratiksha Shankar, Arti P. Gangurde, Manish R. Chauhan, Niraja V. Jaiswal, Pradnya R. Salian, and Vikram Singh. "Accuracy of the digital implant impression with splinted and non-splinted intraoral scan bodies: A systematic review." Journal of Indian Prosthodontic Society 25, no. 1 (2025): 3–12. https://doi.org/10.4103/jips.jips_261_24.

Full text
Abstract:
Introduction: Accurate implant impressions are crucial for successful prosthetic rehabilitation. Digital impressions using intraoral scanners (IOS) have emerged as an alternative to conventional techniques. Various factors influence the accuracy of digital implant impressions, including scan body design, scanning protocol, and splinting techniques. Aim and Objective: To evaluate the difference between splinted and nonsplinted scan bodies in the accuracy of digital impressions for single or multiple implants by measuring distance and angular deviations between superimposed digital impressions.
APA, Harvard, Vancouver, ISO, and other styles
5

Prerna, Kaushik, Lahori Manesh, Shahi Shikha, Sisodiya Siddharth, Agarwal Abhinav, and Srivastava Neha. "An in-vitro study to evaluate the accuracy of master casts obtained from different transfer impression techniques for a multi-unit implant restoration using two different impression materials evaluated by a 3-D optical scanner." Journal of Orofacial Rehabilitation 5, no. 1 (2025): 3–11. https://doi.org/10.5281/zenodo.15557573.

Full text
Abstract:
<strong>Abstract</strong> <strong>Background: </strong>The precise transfer of implant positions from the oral cavity to the working cast is critical for the passive fit of implant-supported prostheses. This study aimed to evaluate and compare the accuracy of master casts obtained through various impression techniques using two elastomeric materials&mdash;Polyvinyl Siloxane (PVS) and Polyether (PE)&mdash;assessed using a 3D optical scanning system (DWOS). <strong>Materials and Methods: </strong>An edentulous maxillary reference model with four internal connection implants was used. Forty impre
APA, Harvard, Vancouver, ISO, and other styles
6

Rezaei Pourmashizi, Zahra, and Parviz Amini. "Determination the effect of different implant impression splinting techniques on the dimensional accuracy: an in vitro study." Oral & Implantology 17, no. 1 (2025): 29–34. https://doi.org/10.11138/oi.v17i1.95.

Full text
Abstract:
The current study aimed to determine the effect of different implant impression splinting techniques on dimensional accuracy. Five analog implant pairs were fixed in 5 jaw models using auto polymerizing resin. After completing the polymerization for 1 week, the impression copings were connected to the analogs. Then, the models were scanned by a laboratory scanner, and the results were used as reference data. In the next step, impression copings were splinted with flowable composite material. Then, the copings were separated from the analogs and connected to one of the analogs by turning 180 de
APA, Harvard, Vancouver, ISO, and other styles
7

Papaspyridakos, Panos, Goran I. Benic, Virginia Lea Hogsett, George Shelby White, Kunal Lal, and German O. Gallucci. "Accuracy of implant casts generated with splinted and non-splinted impression techniques for edentulous patients: an optical scanning study." Clinical Oral Implants Research 23, no. 6 (2011): 676–81. http://dx.doi.org/10.1111/j.1600-0501.2011.02219.x.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Jalalian, Ezatollah, Fariba Balouch, Nazanin Samiei, Hadi Kaseb Ghane, Babak Iranpoor, and Kamilia Ebrahimian. "A comparative analysis of splinted and non-splint in opentray impression techniques on different angled implants." Bioscience Biotechnology Research Communications 10, no. 1 (2017): 109–13. http://dx.doi.org/10.21786/bbrc/10.1/16.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Zakaria, A., AF Kaddah, AE Fayyad, and AY. Al-quitaiby. "EFFECT OF SPLINTING AND NON SPLINTING OF IMPRESSION TRANSFER DURING IMPRESSION MAKING ON THE FIT OF MULTI-IMPLANT SUPPORTED FIXED FULL ARCH FRAMEWORKS. SYSTEMATIC REVIEW AND META-ANALYSIS." December 17, 2017. https://doi.org/10.5281/zenodo.1155212.

Full text
Abstract:
Statement of problem: The best impression technique should be followed during construction of prosthesis to eliminate poor fit of frameworks connected to implant to decrease undue stresses on the various elements. Purpose: The purpose of this review was to evaluate clinical studies comparing splinted and nonsplinted impression techniques regarding passive fit Materials and methods: An electronic search was performed in November 2017 of MEDLINE, and Cochrane Library databases with the key words implant, implants, impression, and impressions. To be included, the study had to investigate the pass
APA, Harvard, Vancouver, ISO, and other styles
10

Aashritha, Shenava. "Evaluation Of Dimensional Accuracy Of The Implant Impression In Angled Implant With Varying Subgingival Depth" - An In Vitro Study." February 16, 2021. https://doi.org/10.19070/2377-8075-21000322.

Full text
Abstract:
Background: Prosthesis misfit can cause both mechanical as well as biologic complications because of the ankylotic nature of the implant osseointegration. Complications may include screw fracture, screw loosening, failure of osseointegration and marginal discrepancy leading to plaque accumulation. The key to a passive fit is to make accurate impressions. Objective: Was to evaluate the dimensional accuracy of the implant impression in angled implant with varying subgingival depth. The study compared two different impression techniques i.e. open tray without splinting the impression copings and
APA, Harvard, Vancouver, ISO, and other styles
More sources
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!