To see the other types of publications on this topic, follow the link: Ocean thermal power plants.

Dissertations / Theses on the topic 'Ocean thermal power plants'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 dissertations / theses for your research on the topic 'Ocean thermal power plants.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

Rizea, Steven Emanoel. "Optimization of Ocean Thermal Energy Conversion Power Plants." Master's thesis, University of Central Florida, 2012. http://digital.library.ucf.edu/cdm/ref/collection/ETD/id/5462.

Full text
Abstract:
A proprietary Ocean Thermal Energy Conversion (OTEC) modeling tool, the Makai OTEC Thermodynamic and Economic Model (MOTEM), is leveraged to evaluate the accuracy of finite-time thermodynamic OTEC optimization methods. MOTEM is a full OTEC system simulator capable of evaluating the effects of variation in heat exchanger operating temperatures and seawater flow rates. The evaluation is based on a comparison of the net power output of an OTEC plant with a fixed configuration. Select optimization methods from the literature are shown to produce between 93% and 99% of the maximum possible amount of power, depending on the selection of heat exchanger performance curves. OTEC optimization is found to be dependent on the performance characteristics of the evaporator and condenser used in the plant. Optimization algorithms in the literature do not take heat exchanger performance variation into account, which causes a discrepancy between their predictions and those calculated with MOTEM. A new characteristic metric of OTEC optimization, the ratio of evaporator and condenser overall heat transfer coefficients, is found. The heat transfer ratio is constant for all plant configurations in which the seawater flow rate is optimized for any particular evaporator and condenser operating temperatures. The existence of this ratio implies that a solution for the ideal heat exchanger operating temperatures could be computed based on the ratio of heat exchanger performance curves, and additional research is recommended.
ID: 031001365; System requirements: World Wide Web browser and PDF reader.; Mode of access: World Wide Web.; Adviser: Marcel Ilie.; Title from PDF title page (viewed May 8, 2013).; Thesis (M.S.M.E.)--University of Central Florida, 2012.; Includes bibliographical references (p. 77-78).
M.S.M.E.
Masters
Mechanical and Aerospace Engineering
Engineering and Computer Science
Mechanical Engineering; Mechanical Systems
APA, Harvard, Vancouver, ISO, and other styles
2

Rodríguez, Buño Mariana. "Near and far field models of external fluid mechanics of Ocean Thermal Energy Conversion (OTEC) power plants." Thesis, Massachusetts Institute of Technology, 2013. http://hdl.handle.net/1721.1/79495.

Full text
Abstract:
Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Civil and Environmental Engineering, 2013.
Cataloged from PDF version of thesis.
Includes bibliographical references (p. 126-130).
The world is facing the challenge of finding new renewable sources of energy - first, in response to fossil fuel reserve depletion, and second, to reduce greenhouse gas emissions. Ocean Thermal Energy Conversion (OTEC) can provide renewable energy by making use of the temperature difference between the surface ocean and deep ocean water in a Rankine cycle. An OTEC plant pumps huge volumes of water from the surface and nearly 1 km depth, and releases it at an intermediate depth. The effects of this enormous flux are crucial to understand since disruption of the ambient temperature stratification can affect the efficiency of the plant itself and of adjacent plants. This thesis aims to study the external fluid mechanics of offshore OTEC power plants, to assess their environmental impact and to help analyze whether OTEC plants can provide a sustainable source of energy. Although there has been interest in OTEC for several decades, so far primarily physical and analytical models have been developed. In this study numerical models are developed to model OTEC operating plants: integral models for the near and intermediate field and a large-scale ocean general circulation model. Two strategies in modeling OTEC plant discharge are used to analyze plume dynamics: the "Brute Force" approach, in which a circulation model, MITgcm, computes the near, intermediate and far field mixing; and the "Distributed Sources and Sinks" approach, in which the near and intermediate field are represented in the circulation model by sources and sinks of mass computed by integral models. This study concludes that the Brute Force modeling strategy is highly computationally demanding and sometimes inaccurate. Such simulations are very sensitive to model resolution and may require the use of unrealistic model parameters. The Distributed Sources and Sinks approach was found to be capable of modeling the plume dynamics accurately. This method can be applied to the study of adjacent OTEC power plant interaction, redistribution of nutrients, and propagation of contaminants.
by Mariana Rodríguez Buño.
S.M.
APA, Harvard, Vancouver, ISO, and other styles
3

Cottam, P. J. "Innovation in solar thermal chimney power plants." Thesis, University College London (University of London), 2018. http://discovery.ucl.ac.uk/10045417/.

Full text
Abstract:
This thesis analyses novel technology for renewable electricity generation: the solar thermal chimney (STC) power plant and the suspended chimney (SC) as a plant component. The STC consists of a solar collector, a tall chimney located at the centre of the collector, and turbines and generators at the base of the chimney. Air heated in the collector rises up the chimney under buoyancy and generates power in the turbines. STCs have the potential to generate large amounts of power, but research is required to improve their economic viability. A state-of-the-art STC model was developed, focussing on accurate simulation of collector thermodynamics, and providing data on flow characteristics and plant performance. It was used to explore power generation for matched component dimensions, where for given chimney heights, a range of chimney and collector radii were investigated. Matched dimensions are driven by the collector thermal components approaching thermal equilibrium. This analysis was complemented with a simple cost model to identify the most cost-effective STC configurations. The collector canopy is an exceptionally large structure. Many of the designs proposed in the literature are either complex to manufacture or limit performance. This thesis presents and analyses a series of novel canopy profiles which are easier to manufacture and can be incorporated with little loss in performance. STC chimneys are exceptionally tall slender structures and supporting their self-weight is difficult. This thesis proposes to re-design the chimney as a fabric structure, held aloft with lighter-than-air gas. The performance of initial, small scale suspended chimney prototypes under lateral loading was investigated experimentally to assess the response to wind loads. A novel method of stiffening is proposed and design of larger prototypes developed. The economic viability of a commercial-scale suspended chimney was investigated, yielding cost reductions compared to conventional chimney designs.
APA, Harvard, Vancouver, ISO, and other styles
4

Rahmqvist, Elin. "On stochastic unit commitment for thermal power plants." Thesis, KTH, Skolan för elektroteknik och datavetenskap (EECS), 2020. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-285519.

Full text
Abstract:
Climate change is a fact, a crisis threatening every country, economy and human. Toprevent this crisis, the emission of greenhouse gases needs to decrease dramatically. 72%of global greenhouse gas emissions in 2016 came from energy production where electricityand heat account for 42% of the 72%. Nevertheless, coal power grew with 28% in2018 to meet the increased demand of electricity. It is therefore of utmost importancethat the resources used in power plants are distributed as efficiently as possible. Unitcommitment is a short-term planning formulation which is part of the planning chain forproduction of electrical energy. An accurate unit commitment can decrease emissionsand costs.The aim of this study is to implement a model for the stochastic behavior of the electricalload into unit commitment. With this, it shall be evaluated, whether this solutionis robust enough for usage in network control. The evaluation needs to assess the reliability,economic impact and the computational e↵ort for solving the stochastic unitcommitment problem.A test system has been created in MATLAB to evaluate the stochastic versus deterministicunit commitment formulation. Scenarios for the stochastic unit commitmenthave been generated by using a stationary, discrete-time Markov Chain to generate loadforecast errors. The Fast Forward Selection method has been used to reduce number ofscenarios to minimize computational e↵ort. The quality of the solution has then beenevaluated with value of the stochastic solution for economic analysis. Loss of load probabilityand energy not served have been used to evaluate the reliability.A stochastic approach gives a more robust solution but can be more expensive in termsof costs. Five scenarios were the optimal choice for the stochastic unit commitmentformulation. Increasing number of scenarios did not improve the reliability and resultedin a more expensive solution. The conclusion of this work can be contradictory but highlightsone of the challenges in electric power systems. A more robust system is usuallymore costly and therefore the players in the system must decide what is most desirablein this particular system. A more reliable but expensive system or a less reliable andless costly system.
Klimatförändringarna är ett faktum, en kris som hotar varje land, ekonomi och människa.‌För att förebygga denna kris måste utsläppen av växthusgaser minska dramatiskt. 72 % av de globala utsläppen av växthusgaser år 2016 kom från energiproduktion där värme och elektricitet stod för 42 % av dessa utsläpp. Trots detta växte kolkraften med 28% år 2018 för att kunna möta den ökande efterfrågan på elektricitet. Det är därför av yttersta vikt att dessa resurser används på ett så e↵ektivt sätt som möjligt. En bra och exakt korttidsplanering av kraftsystem kan minska utsläppen och kostnaderna.Målet med denna studie är att implementera stokastisk last i korttidsplaneringen för ett mindre elkraftsystem med 11 enheter. Detta kräver en robust metod som begränsar beräkningstiden för att säkerställa kontinuerlig och säker drift av elkraftsystemet. Analysen måste utvärdera tillförlitligheten, ekonomiska e↵ekterna och beräkningstiden för att lösa det stokastiska korttidsplaneringsproblemet.Ett testsystem har skapats i MATLAB för att utvärdera den stokastiska kontra deterministiska korttidsplaneringsproblemet. Scenarier för det stokastiska korttidsplaneringen har genererats genom att använda en stationär Markov-kedja för att generera felen i lastprognosen och sedan använda Fast Forward Selection metoden för att minska antalet scenarier för att minimera beräkningsinsatsen. Stokastisk korttidsplanering har sedan utvärderats med värdet av den stokastiska lösningen för ekonomisk analys. Sannolikheten för bortkoppling av last samt icke levererad energi har beräknats för att utvärdera tillförlitligheten.En stokastisk metod ger en mer robust lösning men kan vara dyrare vad gäller kostnader. Fem scenarier var det optimala valet för den stokastiska korttidsplaneringsformuleringen. Ö kande av antal scenarier förbättrade inte tillförlitligheten och resulterade i en dyrare lösning. Slutsatsen i detta arbete kan kännas motsägelsefullt då den deterministiska metoden visar på lägre kostnader medans den stokastiska är mer robust. Detta belyser en av utmaningarna i elkraftsystem. Ett mer robust system är vanligtvis dyrare och därför måste aktörerna i systemet bestämma vad som är mest önskvärt i det specifika systemet. Ett mer tillförlitligt men dyrare system eller ett mindre pålitligt och billigaresystem.
APA, Harvard, Vancouver, ISO, and other styles
5

Assémat, Céline. "Management of thermal power plants through use values." Thesis, KTH, Elektriska energisystem, 2015. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-175811.

Full text
Abstract:
Electricity is an essential good, which can hardly be replaced. It can be produced thanks to a wide rangeof sources, from coal to nuclear, not to mention renewables such as wind and solar. In order to meetdemand at the lowest cost, an optimisation is made on electricity markets between the differentproduction plants. This optimisation mainly relies on the electricity production cost of each technology.In order to include long-term constraints in the short-term optimisation, a so-called use value (oropportunity cost) can be computed and added to the production cost. One long-term constraint thatEDF, the main French electricity producer, is facing is that its gas plants cannot exceed a given numberof operation hours and starts between two maintenances. A specific software, DiMOI, computes usevalues for this double constraint but its parameters needs to be tested in order to improve thecomputation, as it is not thought to work properly.DiMOI relies on dynamic programming and more particularly on an algorithm called Bellman algorithm.The software has been tested with EDF R&D department in order to propose some modellingimprovements. Electricity and gas market prices, together with real plant parameters such as startingcosts, operating costs and yields, were used as inputs for this work, and the results were checkedagainst reality.This study gave some results but they appeared to be invalid. Indeed, an optimisation problem wasdiscovered in DiMOI computing core: on a deterministic context, a study with little degrees of freedomwas giving better profits than a study with more degrees of freedom. This problem origin was notfound precisely with a first investigation, and the R&D team expected the fixing time to be very long.The adaptation of a simpler tool (MaStock) was proposed and made in order to replace DiMOI. Thisproject has thus led to DiMOI giving up and its replacement by MaStock. Time was missing to testcorrectly this tool, and the first study which was made was not completely positive. Further studiesshould be carried out, for instance deterministic ones (using real past data) whose results could becompared to reality.Some complementary studies were made from a fictitious system, in order to study the impact of someparameters when computing use values and operations schedules. The conclusions of these studiesare the little impacts that changes in gas prices and start-up costs parameters have on the global resultsand the importance of an accurate choice in the time periods durations used for the computations.Unfortunately these conclusions might be too specific as they were made on short study periods.Further case studies should be done in order to reach more general conclusions.
APA, Harvard, Vancouver, ISO, and other styles
6

Rennie, Eleanor Jane. "Thermal performance of power station cooling towers." Thesis, University of Nottingham, 1992. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.335762.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

El, Khaja Ragheb Mohamad Fawaz. "Solar-thermal hybridization of Advanced Zero Emissions Power Plants." Thesis, Massachusetts Institute of Technology, 2012. http://hdl.handle.net/1721.1/74434.

Full text
Abstract:
Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2012.
Cataloged from PDF version of thesis.
Includes bibliographical references (p. 43-44).
Carbon Dioxide emissions from power production are believed to have significant contributions to the greenhouse effect and global warming. Alternative energy resources, such as solar radiation, may help abate emissions but suffer from high costs of power production and temporal variations. On the other hand, Carbon Capture and Sequestration allows the continued use of fossil fuels without the CO2 emissions but it comes at an energetic penalty. The Advanced Zero Emissions Plant (AZEP) minimizes this energy loss by making use of Ion Transport Membrane (ITM)-based oxy-combustion to reduce the cost of carbon dioxide separation. This work seeks to assess if there are any thermodynamic gains from hybridizing solar-thermal energy with AZEP. The particular focus is hybridizing of the bottoming cycle with supplemental solar heating. A simple model of parabolic solar trough was used to hybridize a model of the AZEP cycle in ASPEN Plus*. Two cycle configurations are studied: the first uses solar parabolic troughs to indirectly vaporize high pressure steam through Therminol and the second uses parabolic troughs to directly preheat the high pressure water stream prior to vaporization. Simulations of the solar vaporizer hybrid by varying the total area of collectors (holding fuel input constant) show an increase of net electric output from 439MW for the non-hybridized AZEP to 533MW with an input solar share of 38.8%. The incremental solar efficiency is found to be around 16% for solar shares of input ranging from 5% to 38.8%. Moreover, simulations of variable solar insolation for collector area of 550,000 m2 , show that incremental solar efficiency increased with solar insolation reaching a plateau around 17%. Simulations of the direct solar preheater, show a net electric output of 501.3 MW for a solar share of 35%, (an incremental solar efficiency of 13.73%). The power generation and hence incremental efficiency is lower than in hybridization with steam vaporization with the same input solar share. Synergy analysis for the steam vaporization hybrid indicates no thermodynamic gains from hybridization.
by Ragheb Mohamad Fawaz El Khaja.
S.B.
APA, Harvard, Vancouver, ISO, and other styles
8

Allen, Kenneth Guy. "Rock bed thermal storage for concentrating solar power plants." Thesis, Stellenbosch : Stellenbosch University, 2014. http://hdl.handle.net/10019.1/86521.

Full text
Abstract:
Thesis (PhD)--Stellenbosch University, 2014.
ENGLISH ABSTRACT: Concentrating solar power plants are a promising means of generating electricity. However, they are dependent on the sun as a source of energy, and require thermal storage to supply power on demand. At present thermal storage – usually molten salt – although functional, is expensive, and a cheaper solution is desired. It is proposed that sensible heat storage in a packed bed of rock, with air as heat transfer medium, is suitable at temperatures of 500 – 600 °C. To determine if this concept is technically feasible and economically competitive with existing storage, rock properties, packed bed pressure drop and thermal characteristics must be understood. This work addresses these topics. No previously published data is available on thermal cycling resistance of South African rock, and there is limited data from other countries in the proposed temperature range for long-term thermal cycling, so samples were thermally cycled. There is rock which is suitable for thermal storage applications at temperatures of 500 – 600 °C. New maps of South Africa showing where potentially suitable rock is available were produced. Dolerite, found extensively in the Karoo, is particularly suitable. Friction factors were measured for beds of different particles to determine the importance of roughness, shape, and packing arrangement. Five sets of rock were also tested, giving a combined dataset broader than published in any previous study. Limitations of existing correlations are shown. The friction factor is highly dependent on particle shape and, in the case of asymmetric particles, packing method. The friction factor varied by up to 70 % for crushed rock depending on the direction in which it was poured into the test section, probably caused by the orientation of the asymmetric rock relative to the air flow direction. This has not been reported before for rock beds. New isothermal correlations using the volume equivalent particle diameter are given: they are within 15 % of the measurements. This work will allow a techno-economic evaluation of crushed rock beds using more accurate predictions of pumping power than could previously be made. Thermal tests below 80 °C show that bed heat transfer is insensitive to particle shape or type. A heat transfer correlation for air in terms of the volume equivalent diameter was formulated and combined with the E-NTU method. The predicted bed outlet temperatures are within 5 °C of the measurements for tests at 530 °C, showing that the influence of thermal conduction and radiation can be reasonably negligible for a single charge/discharge cycle at mass fluxes around 0.2 kg/m2s. A novel method for finding the optimum particle size and bed length is given: The Biot number is fixed, and the net income (income less bed cost) from a steam cycle supplied by heat from the bed is calculated. A simplified calculation using the method shows that the optimum particle size is approximately 20 mm for bed lengths of 6 – 7 m. Depending on the containment design and cost, the capital cost could be an order of magnitude lower than a nitrate salt system.
AFRIKAANSE OPSOMMING: Gekonsentreerde son-energie kragstasies is n belowende manier om elektrisiteit op te wek, maar hulle is afhanklik van die son as n bron van energie. Om drywing op aanvraag te voorsien moet hulle energie stoor. Tans is termiese stoor – gewoonlik gesmelte sout – hoewel funksioneel, duur, en n goedkoper oplossing word gesoek. Daar word voorgestel dat stoor van voelbare warmte-energie in n gepakte rotsbed met lug as warmteoordrag medium geskik is by temperature van 500 – 600 °C. Om te bepaal of dié konsep tegnies gangbaar en ekonomies mededingend met bestaande stoorstelsels is, moet rotseienskappe, gepakte bed drukval en hitteoordrag verstaan word. Hierdie werk spreek hierdie aspekte aan. Geen voorheen gepubliseerde data is beskikbaar oor die termiese siklus weerstand van Suid-Afrikaanse rots nie, en daar is beperkte data van ander lande in die voorgestelde temperatuurbereik, dus is monsters onderwerp aan termiese siklusse. Daar bestaan rots wat geskik is vir termiese stoor toepassings by temperature van 500 – 600 °C. Nuwe kaarte van Suid-Afrika is opgestel om te wys waar potensieel geskikte rots beskikbaar is. Doleriet, wat wyd in die Karoo voor kom, blyk om veral geskik te wees. Wrywingsfaktore is gemeet vir beddens van verskillende partikels om die belangrikheid van grofheid, vorm en pak-rangskikking te bepaal. Vyf rotsstelle is ook getoets, wat n saamgestelde datastel gee wyer as in enige gepubliseerde studie. Beperkings van bestaande korrelasies word aangetoon. Die wrywingsfaktor is hoogs sensitief vir partikelvorm en, in die geval van asimmetriese partikels, pakkings metode. Die wrywingsfaktor het met tot 70 % gevarieer vir gebreekte rots, afhanklik van die rigting waarin dit in die toetsseksie neergelê is. Dit is waarskynlik veroorsaak deur die oriëntasie van die asimmetriese rots relatief tot die lugvloei rigting, en is nie voorheen vir rotsbeddens gerapporteer nie. Nuwe isotermiese korrelasies wat gebruik maak van die volume-ekwivalente partikel deursnee word gegee: hulle voorspel binne 15 % van die gemete waardes. Hierdie werk sal n tegno-ekonomiese studie van rotsbeddens toelaat wat meer akkurate voorspellings van pompdrywing gebruik as voorheen moontlik was. Termiese toetse onder 80 °C wys dat die warmteoordrag nie baie sensitief is vir partikelvorm en -tipe nie. n Warmte-oordragskorrelasie vir lug in terme van die volume-ekwivalente deursnee is ontwikkel en met die E-NTU-metode gekombineer. Die voorspelde lug uitlaat temperatuur is binne 5 °C van die meting vir toetse by 530 °C. Dit wys dat termiese geleiding en straling redelikerwys buite rekening gelaat kan word vir n enkele laai/ontlaai siklus by massa vloeitempos van omtrent 0.2 kg/m2s. n Oorspronklike metode vir die bepaling van die optimum partikelgrootte en bedlengte word gegee: Die Biot-getal is vas, en die netto inkomste (die inkomste minus die bed omkoste) van n stoomsiklus voorsien met warmte van die bed word bereken. n Vereenvoudigde berekening wat die metode gebruik wys dat die optimum grootte en lengte ongeveer 20 mm en 6-7 m is. Afhangende van die behoueringsontwerp en koste, kan die kapitale koste n orde kleiner wees as dié van n gesmelte nitraatsout stelsel
APA, Harvard, Vancouver, ISO, and other styles
9

Allen, Kenneth Guy. "Performance characteristics of packed bed thermal energy storage for solar thermal power plants." Thesis, Stellenbosch : University of Stellenbosch, 2010. http://hdl.handle.net/10019.1/4329.

Full text
Abstract:
Thesis (MScEng (Mechanical and Mechatronic Engineering))--University of Stellenbosch, 2010.
ENGLISH ABSTRACT: Solar energy is by far the greatest energy resource available to generate power. One of the difficulties of using solar energy is that it is not available 24 hours per day - some form of storage is required if electricity generation at night or during cloudy periods is necessary. If a combined cycle power plant is used to obtain higher efficiencies, and reduce the cost of electricity, storage will allow the secondary cycle to operate independently of the primary cycle. This study focuses on the use of packed beds of rock or slag, with air as a heat transfer medium, to store thermal energy in a solar thermal power plant at temperatures sufficiently high for a Rankine steam cycle. Experimental tests were done in a packed bed test section to determine the validity of existing equations and models for predicting the pressure drop and fluid temperatures during charging and discharging. Three different sets of rocks were tested, and the average size, specific heat capacity and density of each set were measured. Rock and slag samples were also thermally cycled between average temperatures of 30 ºC and 510 ºC in an oven. The classical pressure drop equation significantly under-predicts the pressure drop at particle Reynolds numbers lower than 3500. It appears that the pressure drop through a packed bed is proportional to the 1.8th power of the air flow speed at particle Reynolds numbers above about 500. The Effectiveness-NTU model combined with a variety of heat transfer correlations is able to predict the air temperature trend over the bed within 15 % of the measured temperature drop over the packed bed. Dolerite and granite rocks were also thermally cycled 125 times in an oven without breaking apart, and may be suitable for use as thermal storage media at temperatures of approximately 500 ºC. The required volume of a packed bed of 0.1 m particles to store the thermal energy from the exhaust of a 100 MWe gas turbine operating for 8 hours is predicted to be 24 × 103 m3, which should be sufficient to run a 25-30 MWe steam cycle for over 10 hours. This storage volume is of a similar magnitude to existing molten salt thermal storage.
AFRIKAANSE OPSOMMING: Sonenergie is die grootste energiebron wat gebruik kan word vir krag opwekking. ‘n Probleem met die gebruik van sonenergie is dat die son nie 24 uur per dag skyn nie. Dit is dus nodig om die energie te stoor indien dit nodig sal wees om elektrisiteit te genereer wanneer die son nie skyn nie. ‘n Gekombineerde kringloop kan gebruik word om ‘n hoër benuttingsgraad te bereik en elektrisiteit goedkoper te maak. Dit sal dan moontlik wees om die termiese energie uit die primêre kringloop te stoor, wat die sekondêre kringloop onafhanklik van die primêre kringloop sal maak. Dié gevalle studie ondersoek die gebruik van ‘n slakof- klipbed met lug as hitteoordragmedium, om te bepaal of dit moontlik is om hitte te stoor teen ‘n temperatuur wat hoog genoeg is om ‘n Rankine stoom kringloop te bedryf. Eksperimentele toetse is in ‘n toets-bed gedoen en die drukverandering oor die bed en die lug temperatuur is gemeet en vergelyk met voorspelde waardes van vergelykings en modelle in die literatuur. Drie soorte klippe was getoets. Die gemiddelde grootte, spesifieke hitte-kapasiteit en digtheid van elke soort klip is gemeet. Klip en slak monsters is ook siklies tussen temperature van 30 ºC en 510 ºC verkoel en verhit. Die klassieke drukverlies vergelyking gee laer waardes as wat gemeet is vir Reynolds nommers minder as 3500. Dit blyk dat die drukverlies deur ‘n klipbed afhanklik is van die lug vloeispoed tot die mag 1.8 as die Reynolds nommer groter as omtrent 500 is. Die ‘Effectiveness-NTU’ model gekombineerd met ‘n verskeidenheid van hitteoordragskoeffisiënte voorspel temperature binne 15 % van die gemete temperatuur verskil oor die bed. Doloriet en graniet klippe het 125 sikliese toetse ondergaan sonder om te breek, en is miskien gepas vir gebruik in ‘n klipbed by temperature van sowat 500 ºC Die voorspelde volume van ‘n klipbed wat uit 0.1 m klippe bestaan wat die termiese energie vir 8 ure uit die uitlaat van ‘n 100 MWe gasturbiene kan stoor, is 24 × 103 m3. Dit behoort genoeg te wees om ‘n 25 – 30 MWe stoom kringloop vir ten minste 10 ure te bedryf. Die volume is min of meer gelyk aan dié van gesmelte sout store wat alreeds gebou is.
APA, Harvard, Vancouver, ISO, and other styles
10

Darwish, Mazen. "Modular Hybridization of Solar Thermal Power Plants For Developing Nations." Thesis, KTH, Kraft- och värmeteknologi, 2012. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-104456.

Full text
Abstract:
The current energy scenario in the developing nations with abundant sun resource (e.g. southern Mediterranean countries of Europe, Middle-East & North Africa) relies mainly on fossil fuels to supply the increasing energy demand. Although this long adopted pattern ensures electricity availability on demand at all times through the least cost proven technology, it is highly unsustainable due to its drastic impacts on depletion of resources, environmental emissions and electricity prices. Solar thermal Hybrid power plants among all other renewable energy technologies have the potential of replacing the central utility model of conventional power plants, the understood integration of solar thermal technologies into existing conventional power plants shows the opportunity of combining low cost reliable power and Carbon emission reduction. A literature review on the current concentrating solar power (CSP) technologies and their suitability for integration into conventional power cycles was concluded, the best option was found be in the so called Integrated solar combined cycle systems (ISCCS); the plant is built and operated like a normal combined cycle, with a solar circuit consisting of central tower receiver and heliostat field adding heat to the bottoming Rankine cycle. A complete model of the cycle was developed in TRNSYS simulation software and Matlab environment, yearly satellite solar insolation data was used to study the effect of integrating solar power to the cycle throw-out the year. A multi objective thermo economic optimization analysis was conducted in order to identify a set of optimum design options. The optimization has shown that the efficiency of the combined cycle can be increased resulting in a Levelized electricity cost in the range of 10 -14 USDcts /Kwhe. The limit of annual solar share realized was found to be around 7 % The results of the study indicate that ISCCS offers advantages of higher efficiency, low cost reliable power and on the same time sends a green message by reducing the environmental impacts in our existing power plant systems.
APA, Harvard, Vancouver, ISO, and other styles
11

Edwards, Jacob N. "Thermal energy storage for nuclear power applications." Thesis, Kansas State University, 2017. http://hdl.handle.net/2097/36238.

Full text
Abstract:
Master of Science
Department of Mechanical and Nuclear Engineering
Hitesh Bindra
Storing excess thermal energy in a storage media that can later be extracted during peak-load times is one of the better economical options for nuclear power in future. Thermal energy storage integration with light water-cooled and advanced nuclear power plants is analyzed to assess technical feasibility of different storage media options. Various choices are considered in this study; molten salts, synthetic heat transfer fluids, and packed beds of solid rocks or ceramics. In-depth quantitative assessment of these integration possibilities are then analyzed using exergy analysis and energy density models. The exergy efficiency of thermal energy storage systems is quantified based on second law thermodynamics. The packed bed of solid rocks is identified as one of the only options which can be integrated with upcoming small modular reactors. Directly storing thermal energy from saturated steam into packed bed of rocks is a very complex physical process due to phase transformation, two phase flow in irregular geometries and percolating irregular condensate flow. In order to examine the integrated physical aspects of this process, the energy transport during direct steam injection and condensation in the dry cold randomly packed bed of spherical alumina particles was experimentally and theoretically studied. This experimental setup ensures controlled condensation process without introducing significant changes in the thermal state or material characteristics of heat sink. Steam fronts at different flow rates were introduced in a cylindrical packed bed and thermal response of the media was observed. The governing heat transfer modes in the media are completely dependent upon the rate of steam injection into the system. A distinct differentiation between the effects of heat conduction and advection in the bed were observed with slower steam injection rates. A phenomenological semi-analytical model is developed for predicting quantitative thermal behavior of the packed bed and understanding physics. The semi-analytical model results are compared with the experimental data for the validation purposes. The steam condensation process in packed beds is very stable under all circumstances and there is no effect of flow fluctuations on thermal stratification in packed beds. With these experimental and analytical studies, it can be concluded that packed beds have potential for thermal storage applications with steam as heat transfer fluid. The stable stratification and condensation process in packed beds led to design of a novel passive safety heat removal system for advanced boiling water reactors.
APA, Harvard, Vancouver, ISO, and other styles
12

Miranda, Gilda. "Dispatch Optimizer for Concentrated Solar Power Plants." Thesis, Uppsala universitet, Byggteknik och byggd miljö, 2020. http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-402436.

Full text
Abstract:
Concentrating solar power (CSP) plant is a promising technology that exploits direct normal irradiation (DNI) from the sun to be converted into thermal energy in the solar field. One of the advantages of CSP technology is the possibility to store thermal energy in thermal energy storage (TES) for later production of electricity. The integration of thermal storage allows the CSP plant to be a dispatchable system which is defined as having a capability to schedule its operation using an innovative dispatch planning tool. Considering weather forecast and electricity price profile in the market, dispatch planning tool uses an optimization algorithm. It aims to shift the schedule of electricity delivery to the hours with high electricity price. These hours are usually reflected by the high demand periods. The implementation of dispatch optimizer can benefit the CSP plants economically from the received financial revenues. This study proposes an optimization of dispatch planning strategies for the parabolic trough CSP plant under two dispatch approaches: solar driven and storage driven. The performed simulation improves the generation of electricity which reflects to the increase of financial revenue from the electricity sale in both solar and storage driven approaches. Moreover, the optimization also proves to reduce the amount of dumped thermal energy from the solar field.
APA, Harvard, Vancouver, ISO, and other styles
13

Palu, Ivo. "Impact of wind parks on power system containing thermal power plants = Tuuleparkide mõju soojuselektrijaamadega energiasüsteemile /." Tallinn : TUI Press, 2009. http://digi.lib.ttu.ee/i/?443.

Full text
APA, Harvard, Vancouver, ISO, and other styles
14

Fernandez-Munoz, Raul. "Design of solar power plant with coupled thermal storage." Thesis, Georgia Institute of Technology, 1996. http://hdl.handle.net/1853/16722.

Full text
APA, Harvard, Vancouver, ISO, and other styles
15

NASCIMENTO, WALLACE JOSE DAMASCENO DO. "BIFUEL CONVERSION OF THERMAL POWER PLANTS UNDER UNCERTAINTY: A REAL OPTIONS APPROACH." PONTIFÍCIA UNIVERSIDADE CATÓLICA DO RIO DE JANEIRO, 2008. http://www.maxwell.vrac.puc-rio.br/Busca_etds.php?strSecao=resultado&nrSeq=13379@1.

Full text
Abstract:
FUNDAÇÃO DE APOIO À ESCOLA TÉCNICA
No Brasil, apesar da predominência da participação de usinas hidrelétricas no parque gerador, há alguns anos, devido ao Programa Prioritário de Termeletricidade (PPT), foram implantadas diversas centrais termelétricas movidas a Gás Natural. Muitas são as incertezas apresentadas aos agentes do Setor de Energia Elétrica no Brasil, e mais um risco tem ameaçado estas usinas: a oferta de Gás Natural. A conversão das usinas para bicombustí­vel, possibilitando a utilização de Óleo Diesel como combustível alternativo, surgiu como opção para eliminar este risco. Face às diversas incertezas apresentadas, as técnicas tradicionais de análise econômico-financeira se mostram limitadas para avaliar este investimento e as flexibilidades operacionais, sendo proposto que estas avaliações sejam feitas a partir da Teoria de Opções Reais, que consegue tratar as incertezas e flexibilidades mais adequadamente. As opções operacionais (gerar com Gás Natural ou com Diesel) podem ser vistas como uma seqüência de opções européias de compra (European call option), considerando a conversão como uma opção de mudança de insumo (switch-input Real Option) oferecida ao agente proprietário da usina. O objetivo maior deste trabalho é valorar esta opção para uma térmica instalada no subsistema Sudeste do Brasil, indicando, para cada caso, o prêmio que o agente estaria disposto a pagar pela tecnologia de conversão. Como método de avaliação, são utilizadas Simulações de Monte Carlo, a partir do modelo proposto de remuneração da usina, com as variáveis e incertezas associadas: ní­veis de despacho e contratação, preço do contrato e preço spot da energia elétrica, considerando que os custos variáveis unitários de geração (custos dos combustí­veis) futuros seguem um processo estocástico de Movimento Geométrico Browniano (MGB), além da possí­vel penalidade paga pela usina a ANEEL no caso de ser chamada a despacho pelo ONS e não gerar por falta de combustí­vel. Por fim, algumas análises de sensibilidade são apresentadas.
In Brazil, despite the predominant participation of hydro power plants, some years ago, due to Thermo Power Priority Program (PPT), a large number of Natural Gaspowered plants were implanted. A lot of uncertainties are imposed to the players in the Brazilian Power Market, and one more risk arises: the Natural Gas offer. The bi-fuel conversion arises as an option to rule out this risk, since it allows the use of diesel as alternative fuel to the plant. Because of the many uncertainties presented, traditional techniques of economics and financial analysis are limited to value this investment and its operational flexibilities. Real Options Theory is proposed to value this investment, since it is able to deal more appropriately with the uncertainties and flexibilities. Operational options can be seen as a sequence of European Call Options, considering the conversion as a Switch-Input Real Option offered to the Thermo Power Plant’s owner. The main objective of this paper is to increase this option’s value, to a plant located in the Brazilian Southeast Subsystem, indicating in each case, the premium that the player would be willing to pay for the conversion technology. Monte Carlo Simulation was used as a valuation method, for the plant’s cash-flow model, considering the following variables and uncertainties: dispatch and contract level, contract energy and spot prices. Fuel costs are assumed to follow a Brownian Geometric Motion. The possibility of payment of fines to the Eletricity Regulatory Agency (ANEEL) in case of the power plant be dispatch by the Brazilian ISO (ONS) and not delivery energy to the system because of fuel constraints is also considered. Finally, we present sensitivity analysis.
APA, Harvard, Vancouver, ISO, and other styles
16

Dawson, Karen Margaret. "Advanced thermal hydraulic simulations for human reliability assessment of nuclear power plants." Thesis, Massachusetts Institute of Technology, 2017. http://hdl.handle.net/1721.1/112392.

Full text
Abstract:
Thesis: S.M., Massachusetts Institute of Technology, Department of Nuclear Science and Engineering, 2017.
This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.
Cataloged from student-submitted PDF version of thesis.
Includes bibliographical references (pages 101-102).
Human Risk Assessment (HRA) in the nuclear power industry has advanced in the last two decades. However, there is a lack of understanding of the magnitude of the effect of thermal hydraulic (TH) uncertainties upon the failure probabilities of the operator actions of nuclear units. I demonstrate in this work that there is an effect of TH uncertainties on the operating crew's probability of recognizing errors during a loss of coolant accident (LOCA) initiating event. The magnitude of the effect of the TH uncertainty on the operator's ability to recognize errors is dependent upon the size of the break, the operating state of the plant (in operation or shutting down), and the error that is committed. I utilized an uncertainty software, Dakota, coupled with an advanced TH software, MAAP4, to perform a Monte Carlo analysis to propagate selected TH uncertainties through a LOCA initiating event in which the automatic safety coolant injection system fails to automatically actuate. The operator mission is to manually actuate the safety coolant injection system. Two errors that the operating crew could make are 1) entering fire procedures and 2) testing for saturation of the primary system before the saturation occurs. I calculate the operator failure probabilities using the MERMOS HRA methodology (used by the French electric utility company Electricité de France, EdF). My results show a reduction in scenario failure probability from the values reported by EdF in its published MERMOS Catalogue of more than 80% for the operator recognizing the the error in entering fire procedures. For the error in testing for saturation of the primary system before saturation occurs, I calculated a scenario failure probability in Mode B of 0.0033, while the MERMOS Catalogue listed the scenario failure probability as negligible. My results show that there is an effect from TH uncertainties on operator failure probabilities. This research provides a method of improving the accuracy of failure probabilities in established HRA methodologies using TH simulations.
by Karen Margaret Dawson.
S.M.
APA, Harvard, Vancouver, ISO, and other styles
17

Memon, Ejaz. "Environmental effects of thermal power plant emissions : a case study /." Thesis, National Library of Canada = Bibliothèque nationale du Canada, 2000. http://www.collectionscanada.ca/obj/s4/f2/dsk1/tape4/PQDD_0016/MQ55524.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
18

Spelling, James. "Hybrid Solar Gas-Turbine Power Plants : A Thermoeconomic Analysis." Doctoral thesis, KTH, Kraft- och värmeteknologi, 2013. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-121315.

Full text
Abstract:
The provision of a sustainable energy supply is one of the most importantissues facing humanity at the current time, and solar thermal power hasestablished itself as one of the more viable sources of renewable energy. Thedispatchable nature of this technology makes it ideally suited to forming thebackbone of a future low-carbon electricity system.However, the cost of electricity from contemporary solar thermal power plantsremains high, despite several decades of development, and a step-change intechnology is needed to drive down costs. Solar gas-turbine power plants are apromising new alternative, allowing increased conversion efficiencies and asignificant reduction in water consumption. Hybrid operation is a furtherattractive feature of solar gas-turbine technology, facilitating control andensuring the power plant is available to meet demand whenever it occurs.Construction of the first generation of commercial hybrid solar gas-turbinepower plants is complicated by the lack of an established, standardised, powerplant configuration, which presents the designer with a large number ofchoices. To assist decision making, thermoeconomic studies have beenperformed on a variety of different power plant configurations, includingsimple- and combined-cycles as well as the addition of thermal energy storage.Multi-objective optimisation has been used to identify Pareto-optimal designsand highlight trade-offs between costs and emissions.Analysis of the simple-cycle hybrid solar gas-turbines revealed that, whileelectricity costs were kept low, the achievable reduction in carbon dioxideemissions is relatively small. Furthermore, an inherent trade-off between thedesign of high efficiency and high solar share hybrid power plants wasidentified. Even with the use of new optimised designs, the degree of solarintegration into the gas-turbine did not exceed 63% on an annual basis.In order to overcome the limitations of the simple-cycle power plants, twoimprovements were suggested: the integration of thermal energy storage, andthe use of combined-cycle configurations. Thermal energy storage allowed thedegree of solar operation to be extended, significantly decreasing carbondioxide emissions, and the addition of a bottoming-cycle reduced the electricitycosts. A combination of these two improvements provided the bestperformance, allowing a reduction in carbon dioxide emissions of up to 34%and a reduction in electricity costs of up to 22% compared to a combination ofconventional power generation technologies.
Hållbar energiförsörjning är för närvarande en av de viktigaste frågorna förmänskligheten. Koncentrerad solenergi är nu etablerad som en tillförlitlig källaav förnybar energi. Den reglerbara karaktären hos tekniken gör den specielltintressant för uppbyggnaden av ett framtida koldioxidsnålt elsystem.Kostnaden för elektricitet från nuvarande termiska solkraftverk är hög trottsflera decennier av utveckling. Ett genombrått på tekniknivå krävs för att drivaned kostnaderna. Sol-gasturbiner är ett av de mest lovande alternativen, somger en ökad verkningsgrad samtidigt som vattenkonsumtionen reducerasdrastiskt. Sol-gasturbintekniken gör det möjligt att blandköra solenergi ochandra bränslen för att möta efterfrågan vid alla tidpunkter, en attraktiv aspekt iförhållande till alternativa lösningar.Uppbyggnaden av första generationens kommersiella hybrida solgasturbinkraftverkförsvåras dock av bristen på etablerade och standardiseradekraftverkskonfigurationer. Dessa ger planeraren ett stort antal valmöjlighetersom underlag för beslutsfattande. Termoekonomiska studier har genomförtsför ett flertal olika kraftverkskonfigurationer, däribland kraftverk med enkelcykel, kombikraftverk samt möjligheten att utnyttja termisk energilagring.Pareto-optimala konfigurationer har identifierats med hjälp av multiobjektsoptimeringför att belysa balansen mellan kostnader och utsläpp.Analysen av det enkla hybrida sol-gasturbinkraftverket visade attelektricitetskostnaden hållits på en låg nivå, men att den möjliga minskningen avkoldioxidutsläpp är relativt liten. Dessutom identifierades en inre balans mellanatt bibehålla en hög verkningsgrad hos konfigurationen och en hög andelsolenergi i produktionen. Andelen av solenergi i gasturbinen överskred aldrig63% på årlig bas, även med optimerade kraftverkskonfigurationer.Två förbättringar föreslås för att övervinna begränsningarna hos kraftverk medenkel cykel: integration av termisk energilagring samt nyttjande avkombikraftverkskonfigurationer. Termisk energilagring tillåter en ökad andelsolenergi i driften och reducerar koldioxidutsläppen drastiskt, medan denytterligare cykeln hos kombikraftverket reducerar elektricitetskostnaden.Kombinationen av dessa förbättringar ger den bästa prestandan, med enreduktion av koldioxidutsläppen på upp till 34% och reducerade elektricitetskostnaderpå upp till 22% i jämförelse med andra kombinationer avkonventionella kraftverkskonfigurationer.

QC 20130503

APA, Harvard, Vancouver, ISO, and other styles
19

Kretzschmar, Holger. "The Hybrid Pressurized Air Receiver (HPAR) for combined cycle solar thermal power plants." Thesis, Stellenbosch : Stellenbosch University, 2014. http://hdl.handle.net/10019.1/86377.

Full text
Abstract:
Thesis (MScEng)--Stellenbosch University, 2014.
ENGLISH ABSTRACT: Concentrating solar power technology is a modern power generation technology in which central receiver systems play a significant role. For this technology a field of heliostats is used to reflect solar irradiation to the receiver located on top of the tower. An extensive review has shown that contemporary receiver designs face geometric complexities, lack of thermal efficiency as well as issues with durability and cost. The purpose of this study is to develop a new receiver concept that can potentially reduce these issues. A parametric analysis was used to identify potential means of improvement based on an energy balance approach including sensitivities involved with convection and radiation heat transfer. Design criteria such as the use of headers to minimize pressure drop was also investigated. Based on these findings the hybrid pressurized air receiver was developed which is a combination of tubular and volumetric receiver technologies. The fundamental idea of the receiver was investigated by simulating the ray-tracing and coupled natural convection and radiation heat transfer. The ray-tracing results have shown that the use of quartz glass is a prospective solution to higher allowable flux densities, but with reflection losses in the order of 7 %. The coupled natural convection heat transfer simulation further revealed that the receiver concept effectively eliminates the escape of buoyant plumes and radiative heat losses are minimized. Empirical data was gathered from a medium flux concentrator and good agreement with the numerical results was obtained. The thesis therefore concludes that the research outcomes were met. Ongoing research aims to optimise the receiver concept for a 5MW pilot plant.
AFRIKAANSE OPSOMMING: Gekonsentreerde sonkrag tegnologie is ’n moderne kragopwekkingstegnologie waar sentrale ontvangersisteme ’n beduidende rol speel. Vir hierdie tegnologie word ’n veld heliostate gebruik om sonstraling na die ontvanger wat aan die bopunt van die toring geleë is te reflekteer. ’n Omvattende hersiening het daarop gewys dat kontemporêre ontwerpe van die ontvangers ’n aantal geometriese kompleksiteite, ’n tekort aan termiese doeltreffendheid sowel as probleme in terme van duursaamheid en koste in die gesig staar. Die doel van die studie is om ’n nuwe ontvangerskonsep te ontwikkel wat moontlik hierdie probleme kan verminder. ’n Parametriese analise is gebruik om potensiële maniere van verbetering aan te dui wat gebaseer is op ’n energiebalans benadering; insluitend sensitiwiteite betrokke by konvektiewe en stralingswarmteoordrag. Ontwerpkriteria soos die gebruik van spruitstukke om drukverliese te minimaliseer is ook ondersoek. Gebaseer op hierdie bevindinge is die hibriede saamgepersde-lug ontvanger ontwikkel. Laasgenoemde is ’n kombinasie van buis- en volumetriese ontvangertegnologie. Die fundamentele idee van die ontvanger is ondersoek deur straalberekening asook die gelyktydige natuurlike konveksie en stralingswarmteoordrag te simuleer. Die straalberekeningsresultate het getoon dat die gebruik van kwarts glas ’n moontlike oplossing is om hoër stralingsintensiteit te bereik, maar met refleksieverliese in die orde van 7 %. Die gelyktydige natuurlike konveksie en stralingswarmteoordrag simulasie het verder aan die lig gebring dat die ontvangerkonsep die ontsnapping
APA, Harvard, Vancouver, ISO, and other styles
20

Wagner, Sharon J. "Environmental and Economic Implications of Thermal Energy Storage for Concentrated Solar Power Plants." Research Showcase @ CMU, 2011. http://repository.cmu.edu/dissertations/682.

Full text
APA, Harvard, Vancouver, ISO, and other styles
21

Nixon, Jonathan. "Solar thermal collectors for use in hybrid solar-biomass power plants in India." Thesis, Aston University, 2012. http://publications.aston.ac.uk/18722/.

Full text
Abstract:
This thesis examined solar thermal collectors for use in alternative hybrid solar-biomass power plant applications in Gujarat, India. Following a preliminary review, the cost-effective selection and design of the solar thermal field were identified as critical factors underlying the success of hybrid plants. Consequently, the existing solar thermal technologies were reviewed and ranked for use in India by means of a multi-criteria decision-making method, the Analytical Hierarchy Process (AHP). Informed by the outcome of the AHP, the thesis went on to pursue the Linear Fresnel Reflector (LFR), the design of which was optimised with the help of ray-tracing. To further enhance collector performance, LFR concepts incorporating novel mirror spacing and drive mechanisms were evaluated. Subsequently, a new variant, termed the Elevation Linear Fresnel Reflector (ELFR) was designed, constructed and tested at Aston University, UK, therefore allowing theoretical models for the performance of a solar thermal field to be verified. Based on the resulting characteristics of the LFR, and data gathered for the other hybrid system components, models of hybrid LFR- and ELFR-biomass power plants were developed and analysed in TRNSYS®. The techno-economic and environmental consequences of varying the size of the solar field in relation to the total plant capacity were modelled for a series of case studies to evaluate different applications: tri-generation (electricity, ice and heat), electricity-only generation, and process heat. The case studies also encompassed varying site locations, capacities, operational conditions and financial situations. In the case of a hybrid tri-generation plant in Gujarat, it was recommended to use an LFR solar thermal field of 14,000 m2 aperture with a 3 tonne biomass boiler, generating 815 MWh per annum of electricity for nearby villages and 12,450 tonnes of ice per annum for local fisheries and food industries. However, at the expense of a 0.3 ¢/kWh increase in levelised energy costs, the ELFR increased saving of biomass (100 t/a) and land (9 ha/a). For solar thermal applications in areas with high land cost, the ELFR reduced levelised energy costs. It was determined that off-grid hybrid plants for tri-generation were the most feasible application in India. Whereas biomass-only plants were found to be more economically viable, it was concluded that hybrid systems will soon become cost competitive and can considerably improve current energy security and biomass supply chain issues in India.
APA, Harvard, Vancouver, ISO, and other styles
22

George, K. V. "Source apportionment of particulate matter pollution around a pit head thermal power station." Thesis, IIT Delhi, 2016. http://localhost:8080/iit/handle/2074/7042.

Full text
APA, Harvard, Vancouver, ISO, and other styles
23

Jones, I. D. "Assessment and design of small-scale hydro-electric power plants." Thesis, University of Salford, 1988. http://usir.salford.ac.uk/2212/.

Full text
Abstract:
Appraisal and design of small-scale hydro power plants requires a knowledge of hydraulics, hydrology, civil, mechanical, and electrical engineering, and basic economics. Further, small hydro is site specific in nature and marginal from an economic view point. Methods of appraisal and design are required therefore that will keep engineering fees to a minimum and yet still achieve a reliable evaluation of scheme potential and economics. In this context it should be appreciated that small hydro is not large hydro scaled down, and that small hydro needs its own experts (Ref. 1). This thesis considers techniques for appraisal of small hydropower schemes, the selection and specification of scheme components, their costing and economic evaluation. These appraisal techniques are subsequently applied to regional assessment of small-scale hydro-electric potential in the U. K, and to the development and application of a new type of ultra low-head hydropower generator called the Salford Transverse oscillator (STO). Although this work is predominately concerned with assessment of scheme potential in the U.K., it also draws on experience gained by the writer during short visits to India and Nepal, and during a six month design appraisal for rehabilitation of mini-hydro schemes in Sri Lanka (Ref. 2).
APA, Harvard, Vancouver, ISO, and other styles
24

Banerjee, S. "Ocean energy assessment : an integrated methodology." Thesis, Coventry University, 2011. http://curve.coventry.ac.uk/open/items/16196d0d-e671-489a-ba71-f20cdb6c8df3/1.

Full text
Abstract:
The huge natural energy resources available in the world’s oceans are attracting increasing commercial and political interest. In order to evaluate the status and the degree of acceptability of future Ocean Energy (OE) schemes, it was considered important to develop an Integrated Assessment Methodology (IAM) for ascertaining the relative merits of the competing OE devices being proposed. Initial studies included the gathering of information on the present status of development of the ocean energy systems on wave, OTEC and tidal schemes with the challenges faced for their commercial application. In order to develop the IAM, studies were undertaken for the development and standardization of the assessment tools focussing on: • Life Cycle Assessment (LCA) on emission characteristics. • Energy Accounting (EA) studies. • Environmental Impact Assessment (EIA) over different environmental issues. • Resource captures aspects. • Defining economy evaluation indices. The IAM developed from such studies comprised of four interrelated well defined tasks and six assessment tools. The tasks included the identification of the modus operandi on data collection to be followed (from industry) for assessing respective OE devices, and also advancing relevant guidelines as to the safety standards to be followed, for their deployment at suitable sites. The IAM as developed and validated from case studies in ascertaining relative merits of competing OE devices included: suitable site selection aspects with scope for resource utilisation capability, safety factors for survivability, scope for addressing global warming & energy accounting, the environmental impact assessment both qualitatively and quantitatively on different environmental issues, and the economic benefits achievable. Some of the new ideas and concepts which were also discovered during the development of the IAM, and considered useful to both industry and researchers are given below: • Relative Product Cost (RPC) ratio concept- introduced in making an economic evaluation. This is considered helpful in sensitivity analysis and making design improvements (hybridising etc) for the cost reduction of OE devices. This index thus helps in making feasibility studies on R&D efforts, where the capital cost requirement data and life span of the device is not well defined in the primary stages of development. • Determination of the threshold limit value of the barrage constant - considered useful in determining the efficacy of the planning process. The concept ascertained the relative efficiency achieved for various barrage proposals globally. It could also be applied to suggest the revisions required for certain barrage proposals and also found useful in predicting the basin area of undefined barrage proposal for achieving economic viability. • Estimations made on the future possibility of revenue earnings from the by-products of various OTEC types, including the scope of chemical hubs from grazing type OTEC plants. • Determination of breakeven point- on cost versus life span of wave and OTEC devices studied, which is useful in designing optimum life of the concerned devices. The above stated multi-criterion assessment methodology, IAM, was extended leading to the development of a single criterion model for ascertaining sustainability percent achievable from an OE device and termed IAMs. The IAMs was developed identifying 7 Sustainability Development Indices (SDI) using some the tools of the IAM. A sustainability scale of 0-100 was also developed, attributing a Sustainability Development Load Score (SDLS) percentage distribution pattern over each SDIs, depending on their relative importance in achieving sustainability. The total sum of sustainability development (SD) gained from each SDI gave the IAMs (for the concerned device), indicating the total sustainable percentage achieved. The above IAMs developed, could be applied in ranking OE devices alongside the unsustainable coal power station. A mathematical model of estimating the IAMs was formulated, in order to ascertain the viability to the sustainable development of any energy device. The instruments of IAM and IAMs which have been developed would be helpful to the OE industry in ascertaining the degree of acceptability of their product. In addition it would also provide guidelines for their safe deployment by assessing the relative merits of competing devices. Furthermore, IAM and IAMs would be helpful to researchers undertaking feasibility studies on R&D efforts for material development research, ‘hybridization studies’ (as also new innovations), cost reduction, the performance improvement of respective devices, and any economic gains. With future advancements in OE systems and the availability of field data from large scale commercial applications, the specific values/data of the IAM & IAMs may be refined, but the logic of the models developed in this research would remain the same.
APA, Harvard, Vancouver, ISO, and other styles
25

Williams, Daniel David. "Cold side thermal energy storage system for improved operation of air cooled power plants." Thesis, Massachusetts Institute of Technology, 2012. http://hdl.handle.net/1721.1/78194.

Full text
Abstract:
Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2012.
Cataloged from PDF version of thesis.
Includes bibliographical references (p. 81-82).
Air cooled power plants experience significant performance fluctuations as plant cooling capacity reduces due to higher daytime temperature than nighttime temperature. The purpose of this thesis is to simulate the detailed operation of a cold side thermal energy storage system in order to evaluate its potential. An organic Rankine cycle geothermal power station is used as an example application. Detailed sizing and operation considerations are discussed. Several representative case studies compare the performance of candidate configurations. Operation of the selected configuration is then simulated for a full year and a proposed integration of the system with existing plant hardware is laid out. A correlation between weather trends and production is outlined. Finally an economic cost/benefit analysis performed to determine the payback period for implementing the proposed system. The cold side TES system is shown to shift substantial power generation capability from nighttime to daytime when electrical demand is highest, especially during hot summer months. For example, daily energy production is shown to increase by up to 18% under particularly favorable conditions. This redistribution of the power generation curve is accomplished with less than a 5% reduction in overall annual energy production in Mega-Watt hours. The system is shown to be more effective at shifting power generation capacity during warmer months than cooler months. The reduced day to night temperature fluctuation during cooler months results in a reduced thermal storage benefit under similar parasitic loads. The economic benefits of this system are dependent upon the on-peak vs off-peak electricity prices. Economic analysis using 2011 transient price data from the U.S. Midwest Region results in a small increase in annual income. The increased income from the proposed cold side TES system is found to be insufficient to outweigh the required capital investment at current electricity prices.
by Daniel David Williams.
S.M.
APA, Harvard, Vancouver, ISO, and other styles
26

Gil-García, Álvaro Antonio. "Thermodynamic behaviour of supercritical water as working fluid in advanced coal-fired power plants : simulation and design study." Thesis, University of Birmingham, 2017. http://etheses.bham.ac.uk//id/eprint/7734/.

Full text
Abstract:
The UK is facing an energy crisis due to the closure of old nuclear power plants which will not be replaced until Generation III nuclear reactors are built. Coal is a realistic option to fill the gap, although there is a need to use cleaner and efficient technologies as a means to comply with global environmental regulations. Supercritical coal-fired power is a viable clean coal technology; however the UK National Grid Code is built around conventional power plants, and thus compliance is uncertain. Modelling the thermal behaviour of the supercritical boiler water cycle using computational fluid dynamics is a practical method to approach compliance. The CFD models developed with the software Comsol Multiphysics were validated and verified using experimental and numerical data, respectively. Subsequently, a test-element representing one pipe from the water wall was scaled-down to match computational requirements, and tested at two different thermal boundary conditions. A strong, forcedconvective flow was revealed, with buoyancy effects at the inlet and a considerable influence of thermal acceleration. The sharp changes of the thermo-physical properties were the most influential hydrothermal factor. Heat transfer coefficient peaked near the pipe inlet, and the outlet section showed mild hydro-thermal performance, impaired by the acceleration effects.
APA, Harvard, Vancouver, ISO, and other styles
27

Rawat, Anubhav. "Flow characteristics of high concentration fly ash slurries through pipelines." Thesis, IIT Delhi, 2016. http://localhost:8080/xmlui/handle/12345678/7100.

Full text
APA, Harvard, Vancouver, ISO, and other styles
28

Howard, Dustin F. "Modeling, simulation, and analysis of grid connected dish-stirling solar power plants." Thesis, Georgia Institute of Technology, 2010. http://hdl.handle.net/1853/34832.

Full text
Abstract:
The percentage of renewable energy within the global electric power generation portfolio is expected to increase rapidly over the next few decades due to increasing concerns about climate change, fossil fuel costs, and energy security. Solar thermal energy, also known as concentrating solar power (CSP), is emerging as an important solution to new demands for clean, renewable electricity generation. Dish-Stirling (DS) technology, a form of CSP, is a relatively new player in the renewable energy market, although research in the technology has been ongoing now for nearly thirty years. The first large plant utilizing DS technology, rated at 1.5 MW, came online in January 2010 in Peoria, AZ, and plants rated for several hundred MW are in the planning stages. Increasing capacity of this technology within the utility grid requires extensive dynamic simulation studies to ensure that the power system maintains its safety and reliability in spite of the technological challenges that DS technology presents, particularly related to the intermittency of the energy source and its use of a non-conventional asynchronous generator. The research presented in this thesis attempts to fill in the gaps between the well established research on Stirling engines in the world of thermodynamics and the use of DS systems in electric power system applications, a topic which has received scant attention in publications since the emergence of this technology. DS technology uses a paraboloidal shaped dish of mirrors to concentrate sunlight to a single point. The high temperatures achieved at the focal point of the mirrors is used as a heat source for the Stirling engine, which is a closed-cycle, external heat engine. Invented by the Scottish clergyman Robert Stirling in 1816, the Stirling engine is capable of high efficiency and releases no emissions, making it highly compatible with concentrated solar energy. The Stirling engine turns a squirrel-cage induction generator, where electricity is delivered through underground cables from thousands of independent, autonomous 10-25 kW rated DS units in a large solar farm. A dynamic model of the DS system is presented in this thesis, including models of the Stirling engine working gas and mechanical dynamics. Custom FORTRAN code is written to model the Stirling engine dynamics within PSCAD/EMTDC. The Stirling engine and various other components of the DS system are incorporated into an electrical network, including first a single-machine, infinite bus network, and then a larger 12-bus network including conventional generators, loads, and transmission lines. An analysis of the DS control systems is presented, and simulation results are provided to demonstrate the system's steady state and dynamic behavior within these electric power networks. Potential grid interconnection requirements are discussed, including issues with power factor correction and low voltage ride-through, and simulation results are provided to illustrate the dish-Stirling system's capability for meeting such requirements.
APA, Harvard, Vancouver, ISO, and other styles
29

Ruiz-Cabañas, F. Javier. "Corrosion evaluation of molten salts thermal energy storage (TES) systems in concentrated solar power plants (CSP)." Doctoral thesis, Universitat de Lleida, 2020. http://hdl.handle.net/10803/671680.

Full text
Abstract:
El protagonisme creixent de la tecnologia solar termoelèctrica entre el ventall de les energies renovables es centra en la seva capacitat d’adaptar la seva producció a la demanda energètica exigida. La gestionabilitat d’aquest tipus de centrals s’ha aconseguit amb la integració de sistemes d’emmagatzematge tèrmic en les mateixes. La major part dels sistemes d’emmagatzematge tèrmic, ja sigui els que s’utilitzen a nivell comercial com aquells que es troben en fase de desenvolupament proposen l’ús de sals inorgàniques foses com a medi d’emmagatzematge. Aquestes sals presenten l’inconvenient de la seva alta corrosivitat a altes temperatures. Per un costat, s’han analitzat els fenòmens de corrosió associats a les sals solars utilitzades a la planta pilot TES-PS10 mitjançant la instal·lació de racks de testimonis de corrosió als tancs de sals. A més, al finalitzar l’operació de la instal·lació pilot s’ha dut a terme un estudi post-mortem dels seus. Finalment, amb l’objectiu d’abaratir el cost de l’inventari de sals, s’ha analitzat a nivell de laboratori la corrosivitat de diferents mescles de nitrats de baixa puresa. El segon bloc de la tesi es centra en els sistemes d’emmagatzematge tèrmic en calor latent. Concretament, s’analitza la corrosió associada a la mescla peritèctica 46% LiOH-54% KOH proposta com a material de canvi de fase en un mòdul d’evaporació d’instal·lacions termoelèctriques de generació directa de vapor. D’aquesta forma, s’han dut a terme una sèrie d’assajos a nivell de laboratori amb l’objectiu d’avaluar el comportament envers la corrosió de diferents materials en contacte amb aquests hidròxids.
El creciente protagonismo de la tecnología solar se centra en su capacidad para adaptar su producción a la demanda energética exigida. La gestionabilidad de este tipo de centrales se ha conseguido mediante la integración de sistemas de almacenamiento térmico en sales fundidas. El uso de sales fundidas en sistemas de almacenamiento térmico presenta el hándicap de su corrosividad a alta temperatura. El primer bloque de la Tesis analiza los fenómenos de corrosión asociados a las sales solares en la planta piloto TES-PS10 mediante la instalación de racks de corrosión en los tanques de sales. Además, se ha llevado a cabo un estudio post-mortem de componentes de la instalación. Finalmente, se ha analizado a nivel de laboratorio la corrosividad de distintas mezclas de nitrato de baja pureza. El segundo bloque de la tesis se centra en los sistemas de almacenamiento en calor latente. En concreto, se analiza la corrosión asociada a la mezcla peritéctica 46% LiOH-54% KOH propuesta como material de cambio de fase en el módulo de evaporación en plantas de generación directa de vapor. De este modo, se han llevado a cabo ensayos de corrosión a nivel de laboratorio para evaluar el comportamiento a corrosión de distintos materiales en contacto con los hidróxidos.
The growing of concentrated solar power (CSP) within the different renewable energies is due to its ability to adapt the production to the required energy demand. The dispatchability of this type of plants has been achieved through the integration of molten salts thermal storage systems (TES). Molten salts have a handicap associated to their corrosiveness at high temperature. First block of this Thesis analyzes the corrosion phenomena associated with solar salts used in TES-PS10 pilot plant by installing corrosion racks in the salt tanks. Moreover, a postmortem study of different components was performed after facility shut down. Finally, in order to reduce the cost of the salt inventory in TES systems, the corrosivity of different low purity nitrates mixtures has been analyzed at laboratory scale. The second block of the Thesis focuses on latent heat storage systems. Specifically, it has been analyzed the corrosion associated with the proposed 46% LiOH-54% KOH peritectic mixture as a phase change material in the evaporation module of direct steam generation (DSG) CSP plants. Thus, corrosion tests have been performed at laboratory level to evaluate the corrosion performance of several materials in contact with such hydroxides.
APA, Harvard, Vancouver, ISO, and other styles
30

Otgonbaatar, Uuganbayar. "Methodology for characterization of representativeness uncertainty in performance indicator measurements of thermal and nuclear power plants." Thesis, Massachusetts Institute of Technology, 2016. http://hdl.handle.net/1721.1/107279.

Full text
Abstract:
Thesis: Ph. D., Massachusetts Institute of Technology, Department of Nuclear Science and Engineering, 2016.
This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.
Cataloged from student-submitted PDF version of thesis.
Includes bibliographical references (pages 327-331).
In this thesis, a general Methodology framework to characterize, assess and quantify the representativeness uncertainty in performance indicator measurements in thermal and nuclear plants is presented. The representativeness uncertainty arises from the inherent heterogeneity or the variability of the quantity being measured or from the inadequacy of the physical models used to simulate the measurement. The main objective of the Methodology is to gain a deeper physical understanding of the Representativeness uncertainty of the measurement by using numerical simulation tools such as Computational Fluid Dynamics (CFD) and to quantify various sources of representativeness uncertainty. First, the components of the Methodology are expressed using the normal probability distribution for the uncertainty sources. Second, a non-parametric formulation of the Methodology framework is developed and demonstrated. The use of non-parametric techniques allows the quantification and integration of uncertainties that are not expressed by the normal probability distribution. The Methodology is developed based on the analysis of four industrial Case Studies involving uncertainties in performance indicator measurements to structure the analysis. They are: Mass flow rate measurement by an orifice plate (Case Study 1), Steam Generator recirculation ratio measurement using chemical tracers (Case Study 2), The simulation of cooling tower deformation using a Photomodeler (Case Study 3) and the NOx emission measurement from a Combined Cycle Gas Turbine (Case Study 4). In Case Study 1, the non-parametric bootstrap method was used to quantify sampling, iterative and discretization uncertainties thus demonstrating its applicability to CFD uncertainty analysis. In Case Studies 2,3 and 4, the parametric formulation of the Methodology is used to structure the technical analysis.
by Uuganbayar Otgonbaatar.
Ph. D.
APA, Harvard, Vancouver, ISO, and other styles
31

Анкудинов, А. А., В. А. Васин, Л. А. Ермилов, and Б. Б. Пайчадзе. "Опыт ОАО КТЗ в разработке и эксплуатации насосов для тепловых электростанций." Thesis, Изд-во СумГУ, 2002. http://essuir.sumdu.edu.ua/handle/123456789/21247.

Full text
APA, Harvard, Vancouver, ISO, and other styles
32

Bruce, Robert Alasdair Wilson. "Impacts of variable renewable generation on thermal power plant operating regimes." Thesis, University of Edinburgh, 2016. http://hdl.handle.net/1842/20387.

Full text
Abstract:
The integration of variable renewable energy sources (VRE) is likely to cause fundamental and structural changes to the operation of future power systems. In the United Kingdom (UK), large amounts of price-insensitive and variable-output wind generation is expected to be deployed to contribute towards renewable energy and carbon dioxide (CO2) emission targets. Wind generation, with near-zero marginal costs, limited predictability, and a limited ability to provide upward dispatch, displaces price-setting thermal power plants, with higher marginal costs, changing flexibility and reserve requirements. New-build, commercial-scale, and low-carbon generation capacity, such as CO2 capture and storage (CCS) and nuclear, may impact power system flexibility and ramping capabilities. Low-carbon generation portfolios with price-sensitive thermal power plants and energy storage are therefore likely to be required to manage increased levels of variability and uncertainty at operational timescales. This work builds on a high-resolution wind reanalysis dataset of UK wind sites. The locations of existing and proposed wind farms are used to produce plausible and internally consistent wind deployment scenarios that represent the spatial distribution of future UK wind capacity. Temporally consistent electricity demand data is used to characterise and assess demand-wind variability and net demand ramp events. A unit commitment and economic dispatch (UCED) model is developed to evaluate the likely operating regimes of thermal power plants and CCS-equipped units across a range of future UK wind scenarios. Security constraints for reserve and power plant operating constraints, such as power output limits, ramp rates, minimum up/down times, and start-up times, ensure the operational feasibility of dispatch schedules. The load factors, time spent at different loads, and the ramping and start-up requirements of thermal power plants are assessed. CO2 duration curves are developed to assess the impacts of increasing wind capacity on the distribution of CO2 emissions. A sensitivity analysis investigates the impacts of part-load efficiency losses, ramp rates, minimum up/down times, and start-up/shut-down costs on power plant operating regimes and flexibility requirements. The interactions between a portfolio of energy storage units and flexible CO2 capture units are then explored. This multi-disciplinary research presents a temporally-explicit and detailed assessment of operational flexibility requirements at full 8760 hour resolution, highlighting the non-linear impacts of increasing wind capacity. The methodological framework presented here uses high spatial-and temporal-resolution wind data but is expected to provide useful insights for other VREbased power systems to mitigate the implications of inadequate flexibility.
APA, Harvard, Vancouver, ISO, and other styles
33

Manente, Giovanni. "Analysis and Development of Innovative Binary Cycle Power Plants for Geothermal and Combined Geo-Solar Thermal Resources." Doctoral thesis, Università degli studi di Padova, 2011. http://hdl.handle.net/11577/3421590.

Full text
Abstract:
This thesis analyzes binary cycle power plants (Organic Rankine Cycles) for electricity generation from low enthalpy geothermal resources. The objective is the maximization of the net power output by means of the proper selection of the working fluid and cycle parameters. A critical review of many studies on ORCs in the scientific literature is carried out to provide a basis for an optimization study having the exergy recovery efficiency as objective function. Two working fluids are analyzed taking into account both supercritical and subcritical pressures and different temperatures of the geothermal fluid. The application of advanced techniques derived from Pinch Analysis (HEATSEP method) allowed finding also sub-optimal solutions, corresponding to small deviations of the cycle parameters from the optimal design values. These solutions, although sub-optimal from a thermodynamic point of view, may be selected when different aspects related to the technology, economics, flexibility or safety of the system are considered. The costs of the optimal thermodynamic solutions are estimated using the module costing technique that relates all capital and operating costs to the purchased cost of equipment evaluated for some base conditions. The economic results show the impact of the geothermal fluid temperature and working fluid selection on the economics of the system. The results of this study are applied to the Stillwater real binary cycle power plant that started operating in 2009 in Nevada (USA). The power plant operates at subcritical pressures with isobutane as working fluid and uses a dry cooling system as heat rejection system. Due to the limited geothermal resource the plant net power output is much lower than expected. A detailed off-design model of the power plant is developed using the software Aspen. The model is tested and adjusted against the plant data collected during the first year of operation. After validation, the model is run to evaluate the operating parameters that maximize the annual energy production. A study is then performed to increase the performance of Stillwater geothermal binary power plant with the addition of the solar source. The combination of the high exergy solar resource with the low exergy geothermal resource could provide many benefits such as the improvement of the thermal efficiency and the increase of the power output during the day and especially during the warm season, a time when the energy production of air-cooled geothermal power plants is markedly reduced. The addition of the solar heat in the Stillwater geothermal plant restores operating conditions close to design point also in presence of reduced geothermal flow rate and temperature. The detailed off-design model of Stillwater power plant is used to carry out this hybridization study. Cycle parameters are optimized for different values of the ambient temperature and solar irradiation in order to maximize the annual energy production. Two different designs of hybrid geo-solar plants, with and without storage, are compared, and the levelized cost of electricity (LCOE) of the incremental generation from solar energy is calculated. As expected, this LCOE is quite high due to the high costs of the solar collectors and could be competitive only in presence of appropriate incentives.
La tesi analizza gli impianti a ciclo binario (Organic Rankine Cycles) per generazione di elettricità da risorse geotermiche a bassa entalpia. L'obiettivo è la massimizzazione della potenza netta tramite una selezione appropriata del fluido operativo e dei parametri di ciclo. La valutazione critica di molti studi sui cicli di Rankine organici ha fornito le basi per formulare uno studio di ottimizzazione avente come funzione obiettivo il rendimento di recupero exergetico. Sono analizzati due fluidi operativi considerando sia pressioni supercritiche che subcritiche e diverse temperature del fluido geotermico. L'applicazione di tecniche avanzate derivate dalla Pinch Analysis (metodo HEATSEP) ha consentito di trovare anche soluzioni sub-ottimali, corrispondenti a piccoli scostamenti dei parametri di ciclo dai valori di progetto ottimali. Queste soluzioni, sebbene sub-ottimali da un punto di vista termodinamico, potrebbero essere scelte se venissero considerati anche aspetti legati alla tecnologia, economia, flessibilità o sicurezza del sistema. I costi delle soluzioni termodinamicamente ottimali sono quindi valutati mostrando l'impatto della temperatura del fluido geotermico e della scelta del fluido operativo sull'economia del sistema. I risultati di questo studio sono applicati all'impianto reale a ciclo binario di Stillwater che iniziò l'operazione nel 2009 in Nevada (USA). L'impianto opera a pressioni subcritiche con isobutano come fluido operativo e usa un sistema di raffreddamento ad aria. A causa della limitata risorsa geotermica la potenza netta prodotta dall'impianto è molto più bassa di quella attesa. E' stato sviluppato un modello dettagliato di fuori progetto dell'impianto usando il software Aspen. Il modello è stato validato con i dati dell'impianto raccolti nel primo anno di attività. Dopo validazione il modello è utilizzato per ottenere i parametri operativi che massimizzano la produzione energetica annuale. E' stato quindi effettuato uno studio per aumentare le prestazioni dell'impianto geotermico di Stillwater con l'aggiunta della risorsa solare. I parametri di ciclo sono ottimizzati per valori differenti della temperatura ambiente e della radiazione solare per massimizzare la produzione energetica annuale. Sono confrontate due configurazioni di ciclo ibrido, con e senza accumulo, ed è calcolato il costo dell'energia elettrica (LCOE). Come atteso, questo LCOE è abbastanza elevato a causa dei costi elevati dei collettori solari e potrebbe essere competitivo solo in presenza di incentivi appropriati.
APA, Harvard, Vancouver, ISO, and other styles
34

Guédez, Rafael. "A Techno-Economic Framework for the Analysis of Concentrating Solar Power Plants with Storage." Doctoral thesis, KTH, Kraft- och värmeteknologi, 2016. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-191339.

Full text
Abstract:
Concentrating solar power plants can integrate cost-effective thermal energy storage systems and thereby supply controllable power on demand, an advantage against other renewable technologies. Storage integration allows a solar thermal power plant to increase its load factor and to shift production to periods of peak demand. It also enables output firmness, providing stability to the power block and to the grid. Thus, despite the additional investment, storage can enhance the performance and economic viability of the plants. However, the levelized cost of electricity of these plants yet remains higher than for other technologies, so projects today are only viable through the provision of incentives or technology-specific competitive bid tenders. It is the variability of the solar resource, the myriad roles that storage can assume, and the complexity of enhancing the synergies between the solar field, the storage and the power block, what makes the development of adequate policy instruments, design and operation of these plants a challenging process. In this thesis a comprehensive methodology for the pre-design and analysis of concentrating solar power plants is presented. The methodology is based on a techno-economic modeling approach that allows identifying optimum trade-off curves between technical, environmental, and financial performance indicators. A number of contemporary plant layouts and novel storage and hybridization concepts are assessed to identify optimum plant configurations, in terms of component size and storage dispatch strategies. Conclusions highlight the relevance between the sizing of key plant components, the operation strategy and the boundaries set by the location. The interrelation between critical performance indicators, and their use as decisive parameters, is also discussed. Results are used as a basis to provide recommendations aimed to support the decision making process of key actors along the project development value chain of the plants. This research work and conclusions are primarily meant to set a stepping stone in the research of concentrating solar power plant design and optimization, but also to support the research towards understanding the value of storage in concentrating solar power plants and in the grid.
Koncentrerad solkraft erbjuder möjligheten att integrera kostnadseffektiv termisk energilagring och därmed behovsstyrd kraftkontroll. Detta är en viktig fördel jämfört med andra förnybara energiteknologier. Lagringsintegration tillåter solkraftsanläggningar att öka sin lastfaktor och skifta produktion till tider med största efterfrågan. Vidare möjliggör lagring fast elproduktion vilket leder till förbättrad nät- och kraftturbinstabilitet. Därför kan termisk lagring öka anläggningsprestanda och ekonomiskt värde trots ökande initiala kapitalkostnader. I termer av specifik elproduktionskostnad (LCOE) ligger koncentrerade solkraftsanläggningar med lagring fortfarande högre än andra kraftteknologier och anläggningsprojekt blir endast lönsamma genom subventionsmodeller eller teknologispecifika konkurrensutsatta anbudsförfaranden. Att hitta adekvata policylösningar och optimala design och operationsstrategier är en utmanande process eftersom det gäller att hitta rätt balans mellan variabel solinstrålning, lagring av energi och tid för produktion genom optimal design och operation av solmottagarfält, kraftblock och lagringskapacitet. I denna avhandling presenteras en omfattande metodik för pre-design och analys av koncentrerande solkraftverk. Metodiken baseras på en tekno-ekonomisk modelleringsansats som möjliggör identifiering av optimala avvägningssamband för tekniska, ekonomiska och miljöprestanda indikatorer. Metodiken tillämpas på ett antal moderna anläggningslayouter  och lagrings- och hybridiseringskoncept för att identifiera optimal kraftanläggningsdesign i termer av komponentprestanda och lagringsanvändningsstrategier. I slutsatsen poängteras relevansen av att hitta rätt storlek på nyckelkomponenter i relation till lagringsstrategi och randvillkoren som ges av konstruktionsläget för optimal ekonomisk och miljömässig prestanda. Resultaten används för att formulera rekommendationer till nyckelaktörer i beslutsprocessen genom hela kraftanläggningens värdekedja från politisk beslutsfattare till anläggningsingenjör. Forskningen och slutsatserna i detta arbete skall i första hand ta ett steg framåt för optimering och design av solkraftsanläggningar men även tillhandahålla en metodik för utvärdering av lagringslösningar och dess specifika värde för solkraftsanläggningar och elnätet.

QC 20160829

APA, Harvard, Vancouver, ISO, and other styles
35

Richter, Pascal [Verfasser], Martin Akademischer Betreuer] Frank, Siegfried [Akademischer Betreuer] [Müller, and Diaz Manuel J. [Akademischer Betreuer] Castro. "Simulation and optimization of solar thermal power plants / Pascal Richter ; Martin Frank, Siegfried Müller, Manuel J. Castro Diaz." Aachen : Universitätsbibliothek der RWTH Aachen, 2017. http://d-nb.info/1162498692/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
36

Bachelier, Camille [Verfasser], and R. [Akademischer Betreuer] Stieglitz. "Techno-economical analyses of linear solar thermal electric plants for dispatchable power generation / Camille Bachelier ; Betreuer: R. Stieglitz." Karlsruhe : KIT-Bibliothek, 2021. http://d-nb.info/1238148115/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
37

Rader, Jordan D. "Loss of normal feedwater ATWS for Vogtle Electric Generating Plant using RETRAN-02." Thesis, Atlanta, Ga. : Georgia Institute of Technology, 2009. http://hdl.handle.net/1853/31741.

Full text
Abstract:
Thesis (M. S.)--Nuclear Engineering, Georgia Institute of Technology, 2010.
Committee Chair: Abdel-Khalik, Said I.; Committee Member: Ghiaasiaan, S. Mostafa; Committee Member: Hertel, Nolan E. Part of the SMARTech Electronic Thesis and Dissertation Collection.
APA, Harvard, Vancouver, ISO, and other styles
38

Ehtiwesh, Ismael Alagili Sassi. "Exergetic, energetic, economic and environmental evaluation of concentrated solar power plants in Libya." Doctoral thesis, Universidade de Aveiro, 2016. http://hdl.handle.net/10773/15882.

Full text
Abstract:
Doutoramento em Engenharia Mecânica
The PhD project addresses the potential of using concentrating solar power (CSP) plants as a viable alternative energy producing system in Libya. Exergetic, energetic, economic and environmental analyses are carried out for a particular type of CSP plants. The study, although it aims a particular type of CSP plant – 50 MW parabolic trough-CSP plant, it is sufficiently general to be applied to other configurations. The novelty of the study, in addition to modeling and analyzing the selected configuration, lies in the use of a state-of-the-art exergetic analysis combined with the Life Cycle Assessment (LCA). The modeling and simulation of the plant is carried out in chapter three and they are conducted into two parts, namely: power cycle and solar field. The computer model developed for the analysis of the plant is based on algebraic equations describing the power cycle and the solar field. The model was solved using the Engineering Equation Solver (EES) software; and is designed to define the properties at each state point of the plant and then, sequentially, to determine energy, efficiency and irreversibility for each component. The developed model has the potential of using in the preliminary design of CSPs and, in particular, for the configuration of the solar field based on existing commercial plants. Moreover, it has the ability of analyzing the energetic, economic and environmental feasibility of using CSPs in different regions of the world, which is illustrated for the Libyan region in this study. The overall feasibility scenario is completed through an hourly analysis on an annual basis in chapter Four. This analysis allows the comparison of different systems and, eventually, a particular selection, and it includes both the economic and energetic components using the “greenius” software. The analysis also examined the impact of project financing and incentives on the cost of energy. The main technological finding of this analysis is higher performance and lower levelized cost of electricity (LCE) for Libya as compared to Southern Europe (Spain). Therefore, Libya has the potential of becoming attractive for the establishment of CSPs in its territory and, in this way, to facilitate the target of several European initiatives that aim to import electricity generated by renewable sources from North African and Middle East countries. The analysis is presented a brief review of the current cost of energy and the potential of reducing the cost from parabolic trough- CSP plant. Exergetic and environmental life cycle assessment analyses are conducted for the selected plant in chapter Five; the objectives are 1) to assess the environmental impact and cost, in terms of exergy of the life cycle of the plant; 2) to find out the points of weakness in terms of irreversibility of the process; and 3) to verify whether solar power plants can reduce environmental impact and the cost of electricity generation by comparing them with fossil fuel plants, in particular, Natural Gas Combined Cycle (NGCC) plant and oil thermal power plant. The analysis also targets a thermoeconomic analysis using the specific exergy costing (SPECO) method to evaluate the level of the cost caused by exergy destruction. The main technological findings are that the most important contribution impact lies with the solar field, which reports a value of 79%; and the materials with the vi highest impact are: steel (47%), molten salt (25%) and synthetic oil (21%). The “Human Health” damage category presents the highest impact (69%) followed by the “Resource” damage category (24%). In addition, the highest exergy demand is linked to the steel (47%); and there is a considerable exergetic demand related to the molten salt and synthetic oil with values of 25% and 19%, respectively. Finally, in the comparison with fossil fuel power plants (NGCC and Oil), the CSP plant presents the lowest environmental impact, while the worst environmental performance is reported to the oil power plant followed by NGCC plant. The solar field presents the largest value of cost rate, where the boiler is a component with the highest cost rate among the power cycle components. The thermal storage allows the CSP plants to overcome solar irradiation transients, to respond to electricity demand independent of weather conditions, and to extend electricity production beyond the availability of daylight. Numerical analysis of the thermal transient response of a thermocline storage tank is carried out for the charging phase. The system of equations describing the numerical model is solved by using time-implicit and space-backward finite differences and which encoded within the Matlab environment. The analysis presented the following findings: the predictions agree well with the experiments for the time evolution of the thermocline region, particularly for the regions away from the top-inlet. The deviations observed in the near-region of the inlet are most likely due to the high-level of turbulence in this region due to the localized level of mixing resulting; a simple analytical model to take into consideration this increased turbulence level was developed and it leads to some improvement of the predictions; this approach requires practically no additional computational effort and it relates the effective thermal diffusivity to the mean effective velocity of the fluid at each particular height of the system. Altogether the study indicates that the selected parabolic trough-CSP plant has the edge over alternative competing technologies for locations where DNI is high and where land usage is not an issue, such as the shoreline of Libya.
O projeto de Doutoramento aborda o potencial de usar centrais de energia solar concentrada (CSP) como um sistema de produção de energia alternativa disponível na Líbia. Uma análise nas vertentes exergética, energética, económica e ambiental foi realizada para um tipo particular destas centrais – um sistema de 50 MW com receção parabólica, porém ela é suficientemente geral para ser aplicada a outras configurações. A originalidade do estudo, para além da modelação e análise da configuração selecionada encontra-se na utilização do estado da arte em termos da análise exergética combinada com a avaliação do ciclo de vida (LCA). A modelação e simulação da central CSP selecionada são efetuadas no terceiro capítulo tendo em consideração as duas componentes: ciclo de potência e campo de coletores solar. O modelo computacional para a análise do sistema foi desenvolvido com base em equações algébricas que descrevem o sistema, e que são resolvidas usando o software EES. Deste modo, são definidas as propriedades em cada ponto de interesse para os diferentes elementos do sistema, o que assim permite determinar as energias, eficiências e irreversibilidades desses elementos. O modelo desenvolvido tem o potencial de se tornar uma ferramenta de grande utilidade para o projeto preliminar de engenharia de centrais CSP, e também para a avaliação da eventual reconfiguração de centrais elétricas solares comerciais em operação. Além disso, o modelo pode ser utilizado no estudo de viabilidade da operação de centrais CSP, através da análise energética, económica e ambiental, para regiões diferentes da que foi escolhida no presente estudo -Trípoli (Líbia). O cenário total da viabilidade da operação da central CSP é completado através da análise horária com base anual apresentada no quarto capítulo. Esta análise permite a comparação de diferentes sistemas e, eventualmente permite fazer a seleção com base nas componentes económicas e energéticas, que são determinadas dentro do contexto do software greenius. A análise também toma em conta o impacto de financiamento e incentivos dados aos projetos no custo da produção de energia. O principal resultado desta análise é a verificação que o desempenho é mais elevado, com o consequente menor custo nivelado da eletricidade, para a Líbia em comparação com o Sul da Europa (Espanha). Assim a Líbia tem o potencial de se tornar um candidato atrativo para o estabelecimento de centrais CSP com o objetivo, como foi considerado em várias iniciativas europeias, de exportar eletricidade gerada através de fontes de energia renováveis de países do Norte de África e Médio Oriente para a Europa. A análise apresenta uma breve revisão do custo corrente da eletricidade e o potencial para reduzir o custo da energia a partir da tecnologia de receção parabólica de centrais CSP. A avaliação do ciclo de vida com base exergética (ELCA) e a avaliação do ciclo de vida convencional são realizadas para a centrais CSP específicas no quinto capítulo. Os objetivos são 1) avaliar o impacto ambiental e custo, em termos de do ciclo iv de vida exergético do sistema; 2) identificar pontos fracos em termos da irreversibilidade dos processos; e 3) verificar se as centrais CSP podem reduzir o impacto ambiental e o custo de geração de eletricidade em comparação com centrais que consomem combustível fóssil. O capítulo ainda apresenta uma análise termoeconómica com base na metodologia do custo específico da exergia (SPECO), que avalia o custo relacionado com a destruição de exergia. A análise verificou que o impacto mais importante é a contribuição apresentada pelo campo solar (79%), e os materiais com maior impacto são: aço (47%), sal fundido (25%) e óleo sintético (21%). A análise ELCA mostra que a maior demanda de exergia é devida ao aço (47%); a análise existe uma considerável demanda de exergia relacionada com o sal fundido e ainda o óleo sintético. Em comparação com as centrais que consomem combustível fóssil (NGCC e óleo) a central sistema CSP apresenta menor impacto ambiental, enquanto o pior desempenho ambiental é o da central com queima de óleo seguida pela central a gás natural (NGCC). Na central CSP, o campo solar apresenta o custo mais elevado, enquanto o gerador de vapor, entre os componentes do ciclo de potência, apresenta o maior custo. O armazenamento de energia térmica permite que as centrais CSP superem a intermitência de radiação solar para responder à procura de energia elétrica independentemente das condições climáticas, e também possam estender a produção de eletricidade para além da disponibilidade da radiação solar diária. A análise numérica do transiente térmico de um sistema de armazenamento de gradiente térmico é realizada durante a fase de carregamento. O sistema de equações que descreve o modelo numérico é resolvido através da utilização de diferenças finitas implícitas no tempo usando o software Matlab. Os resultados da análise indicam que as previsões estão em boa concordância com os dados experimentais para a evolução no tempo da região de gradiente térmico, em particular para regiões mais afastadas da entrada. Nesta região os desvios observados são provavelmente causados pelo alto nível de turbulência devido à penetração do jato no seio do tanque de armazenamento. O modelo analítico simples para simular a turbulência que foi desenvolvido melhora os resultados. Esta abordagem não requer esforço computacional adicional e determina a difusidade térmica efetiva ao longo do tanque.
APA, Harvard, Vancouver, ISO, and other styles
39

Beviss-Challinor, Lauren Margaret. "Design, build and test a passive thermal system for a loft : a roof solar chimney application for South African weather conditions." Thesis, Stellenbosch : Stellenbosch University, 2007. http://hdl.handle.net/10019.1/348.

Full text
Abstract:
Thesis (MEng (Mechanical and Mechatronic Engineering))--Stellenbosch University, 2007.
ENGLISH: The design, construction and testing of a passive thermal system, a roof solar chimney, for a loft is considered. Unlike conventional solar chimneys the solar collector is constructed from corrugated iron roof sheets with the aim that it can be integrated into existing buildings at a lower cost or used in low cost housing developments. The main objective of the study was to determine the feasibility of such low-cost design to regulate thermal conditions in a loft, that is heating the loft during winter and enhancing natural ventilation during summer, by carrying out an experimental and analytical study. The results obtained from the experimental study showed that for winter the solar chimney, having a channel width, depth and length of 0.7 m, 0.1 m and 1.8 m respectively and with a peal solar radiation of 850 W/m², heated the room air 5°C higher than the ambient temperature during the hottest periods of the day, which is only marginally better than a loft with conventional roof insulation. At night, it was found that reverse airflow occurred through the chimney, cooling the loft down to ambient temperature, due to radiation heat loss from the roof collector to the night sky. For summer operation, the experimental data showed that the chimney was able to maintain the loft at ambient temperature and the analytical study found that the chimney was able to enhance natural ventilation effectively, reaching air exchange rate of 6.6 per hour for the 4.6 m³ volume space. It was also found that the chimney’s performance dropped rapidly and significantly during periods of low solar radiation and at night. A sensitivity analysis illustrated that for both summer and winter operation, the size, tilt angle and absorptivity of the roof collector greatly effected the efficiency and mass flow rates of the system, agreeing well with other literature. These results prove that this low cost solar chimney cooling design was feasible to enhance natural ventilation mainly during hot summer conditions with high solar radiation. Compared to a loft with only conventional roof insulation, the chimney did not perform effectively during the winter to heat the loft up, meaning that winter operation for this specific design is not feasible. Possible improvements to the design include using construction materials with higher thermal capacities to retain heat energy and ensure continued operation during periods of low solar radiation, as well as using selective absorber coatings on the collector surface. It is recommended that further work on the project include the integration of these improvements into the present design and to use the findings obtained from the sensitivity analysis to improve system efficiencies. CFD analysis of the test-rig will be insightful as an additional means to validate and compare with the analytical and experimental data obtained in this report. With the continuation of these studies, this low-cost solar chimney design can be optimised, validated on a commercial scale and built into existing and new housing developments. Incorporating such a passive thermal device will aid homeowners in air regulation and thermal comfort of their living space as well as saving on energy requirements.
Sponsored by the Centre for Renewable and Sustainable Energy Studies, Stellenbosch University
APA, Harvard, Vancouver, ISO, and other styles
40

Rizzi, M. "HIGH TEMPERATURE OXIDATION PHENOMENA'S STUDY OF HIGH ALLOYED MATERIALS FOR POWER GENERATION PLANTS." Doctoral thesis, Università degli Studi di Milano, 2012. http://hdl.handle.net/2434/168364.

Full text
Abstract:
The aim of the doctorate project is the study of the corrosion and oxidation behavior of some commercial and more recent SS and Ni based alloys for high temperature applications in order to verify their possible use either at operative conditions higher than conventional (temperature up to 900°C) or in different environment (oxygen, air, carburizing atmospheres). During the first year, the following aspects were investigated: - Microstructural characterization of solution annealed AISI 310N, 347HFG and 304 HCu (the latter supplied also in the shoot peened condition) was carried out. An homogeneous austenitic fine grain structure accompanied with Nb segregation was observed for 347HFG and 304HCu. In the case of 310N the grains were coarser and the presence of Si segregation were randomly detected beside Nb. - Microhardness profiles (HV50) were conducted to evaluate the penetration effects of shoot peening treatment at depths as high as 150-200 m. - Discontinuous oxidation testing were performed at temperatures in the range of 700-900°C under 15 Nm3/h flowing moist air atmosphere for 7 days. The preliminary results seem to confirm an oxidation susceptibility in the following order: 310N<347HFG<304HCu. During the second year, the following activities have been carried out: - Oxidation kinetic study (thermogravimetric tests) of as received AISI 310N, 347HFG, 304HCu and Alloy 617 in oxygen atmosphere at 900°C; 310N, 347HFG and Alloy 617 show a protective oxidation kinetic, while 304HCu suffers from spalling. - Investigation of grown oxide layer nature of all SS by microscopic techniques revealed an average oxide thickness in the range of 5 – 15 m for 347HFG; about 5 m until spallation for 304HCu and less than 5 m for 310N. In the case of 347HFG a three layer oxide was clearly detected consisting of a first layer of Cr oxides followed by a mixed Fe and Cr oxide and finally an external layer of FeOx. For 310N only a Cr oxide layer was detectable; for 304HCu the layer being essentially Fe-Cr oxides. Result confirmed also by GDOES. - Study of the electrochemical behaviour of as received and oxidized SS specimens by means of polarization curves. All “as received” specimens exhibit a similar passive behaviour in terms of both potentials and current densities, apart the point corresponding at the critical passive current (icr). For oxidized specimens a statistical approach should be followed. During the third year, in addition to the accomplishment of the previous topics, new electrochemical approaches were tested during a period spent by the candidate following Dr. Digby Macdonald's research labs at The Pennsylvania State University. Activities were focused on the passivity study of 347HFG stainless steel. Starting from the results of the potentiodynamic studies, an electrochemical impedance spectroscopy procedure was setted up; results were optimized by applying the “point defect model” developed by the same Dr. Macdonald revealing kinetic parameters of the passive layer and is semiconductive nature that is essentially n-type for all anodic potential values except near the breakdown in which assume a p-type character.
APA, Harvard, Vancouver, ISO, and other styles
41

Llovera, Bonmatí Albert. "Market role, profitability and competitive features of thermal power plants in the Swedish future electricity market with high renewable integration." Thesis, Uppsala universitet, Elektricitetslära, 2017. http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-330392.

Full text
Abstract:
The Swedish energy market is currently undergoing a transition from fossil fuels to renewable energy sources, including a potential phase-out of nuclear power. The combination of a phase-out with expansion of intermittent renewable energy leads to the issue of increased fluctuations in electricity production. Energy-related organizations and institutions are projecting future Swedish energy scenarios with different possible transition pathways. In this study the market role of thermal power plants is assessed in two future scenarios. The fast start-up time of gas turbines means that they can balance out fluctuations. Given that a large share of reports already studies costs of the system, this report instead investigates the profitability, potential market roles, and competitive features of these technologies in the future market.
APA, Harvard, Vancouver, ISO, and other styles
42

Lundholm, Diana. "Thirsty coal: Assessing climate change impacts on water availability and vulnerability of thermal power plants in Poland up to 2050." Thesis, Uppsala universitet, Institutionen för geovetenskaper, 2021. http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-445133.

Full text
Abstract:
This thesis identifies the potential threats and impacts posed by climate change on the relationship between water availability and the Polish energy transformation sector. In doing so, the objective is to uncover and assess how vulnerable these components are to climate change. Poland provides an interesting case in a European context as the country’s energy sector is largely fueled by hard coal, and its established thermal power plant fleet requires large volumes of water at particular temperatures to operate at full capacity (Kosowski et al. 2019). Climate change is predicted to cause variations in temperature and precipitation which is likely to affect water availability (Schaeffer et al. 2012). This is set to place further strain on the relationship betweenwater and thermal power plant operation. In addition, Poland has some of the smallest freshwater resources available per capita in the European Union and the country has already witnessed an increase in droughts and heatwaves which have had negative impacts on electricity generation (Manowska & Rybak 2018; Olszewski2015). The concern for Poland then is that climate change threatens the energy transformation sectors’ ability to provide access to electricity by continuing to affect water availability. To investigate this, the study conducted a vulnerability assessment that aimed to identify climate change exposure through the analysis of different climate models. A content analysis of relevant literature was used to identify potential climate change threats. To place the assessment in the Polish context, a case study was conducted on 14 hard coal thermal power plants located throughout the country. The data gathered from the case study was then evaluated and discussed in relation to the conceptual framework. The results found that climate change is indeed causing higher airtemperatures which is likely to cause higher water temperatures as well as more extreme weather events. These trends are expected to continue well beyond 2050. Regarding water availability, it was more challenging to identify a significant change in precipitation trends but periods of intense rainfall and increases in mean watertemperatures were observed. The thesis concluded that it is difficult to predict the exact degree of vulnerability of water availability and thermoelectric power operation. It does however recognize that there is a clear relationship between water availability and the functioning of thermal power plants. Therefore, it can be said that climate change will, to a certain extent, expose the two components to further vulnerabilities. Yet, further in-depth research is required to improve the reliability of the results.
APA, Harvard, Vancouver, ISO, and other styles
43

Dolek, Emre. "Comparison Of Iscst3 And Aermod Air Dispersion Models: Case Study Of Cayirhan Thermal Power Plant." Master's thesis, METU, 2007. http://etd.lib.metu.edu.tr/upload/12609207/index.pdf.

Full text
Abstract:
In this study, emission inventory was prepared and pollutant dispersion studies were carried out for the area around Ç
ayirhan Thermal Power Plant to determine the effects of the plant on the environment. Stack gas measurement results were used for the emissions from the power plant and emission factors were used for calculating the emissions from residential sources and coal stockpiles in the study region. Ground level concentrations of SO2, NOx and PM10 were estimated by using EPA approved dispersion models
namely ISCST3 and AERMOD. The ground level concentrations predicted by two models were compared with the results of ambient air pollution measurements for November 2004. Predictions of both ISCST3 and AERMOD were underestimating the ground level SO2 concentrations. However, AERMOD predictions are better than ISCST3 predictions. The results of both models had good correlation with the results of NOx measurements. It has been shown that the contribution of the power plant to SO2, NOx and PM10 pollution in the area studied is minimal.
APA, Harvard, Vancouver, ISO, and other styles
44

Pragada, Gandhi, and Nitish Perisetla. "Utility-Scale Solar Power Plants with Storage : Cost Comparison and Growth Forecast Analysis." Thesis, KTH, Skolan för industriell teknik och management (ITM), 2021. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-301838.

Full text
Abstract:
Renewable energy for energy production, like Solar, is turning out to be very pertinent in today's world [1]. It is very clear that Solar Energy is going to emerge as one of the key sources of energy in future. Moreover, the storage option is going to play an essential role to the future deployment of solar power plants. Concentrated solar power plants with thermal storage, photovoltaic plants integrated with battery energy storage, and hybrid plants are attractive solutions to obtain a stable and dispatchable energy production. Investors or policymakers usually find it challenging to come up with the most feasible solar storage technology because they need to consider techno-economic feasibility, and at the same time, from a market or administrative perspective as well. So, this thesis study will address the key problem which is aimed at investors or policymakers since there is a need to choose the best solar storage technology at a utility level in future based on so many attributes. The thesis project was carried out in two phases which includes forecast modelling & estimations and techno-economic assessment of virtual plants. These two phases helped to address various questions in relation to the problem statement of this study. The entire thesis study broadly covered seven countries spanning across four major regions around the world. The first phase of the thesis, forecast modelling estimations shows how the seven countries will look in future (2020 – 2050) with respect to installed capacity and costs for PV, CSP, and BESS technologies. Some major results from phase 1 include, in low-cost estimates, China will remain to be the market leader in PV & CSP by 2050. In U.S.A and India, the installed costs of PV are projected to decline by 70% by 2050. By 2050, the installed costs of Solar Tower technology are estimated to drop by about 65% in China and Spain. In U.S.A, the prices of BESS technology are likely to fall by around 58 – 60 % by 2050. In the second phase of thesis study, a techno-economic evaluation of virtual plants addressed the aspects which are to be considered for a solar project if it is deployed in future across seven specific countries. Results from this analysis helps investors or policymakers to choose the cheapest solar storage technology at a utility level across seven specific countries in future (2020 – 2050). Key results from this analysis show that, in the U.S.A, by 2050, PV+BESS will be the cheapest storage technology for 4 – 10 storage hours. Addition of another renewable technology will add up more viability to the comparison. In China, Hybrid will be the cheapest storage technology for 4 – 8 hrs by 2050. There is huge potential for deployment of CSP & hybrid plants in future than PV. In South Africa, CSP will be the cheapest storage technology by 2050 for 4 – 10 hours of storage. It is assumed that deployment of BESS projects at utility level starts from 2025 in South Africa. Beyond this, market forces analysis was carried out which offers insights especially for the policymakers of how various drivers and constraints are influencing each solar technology across the specific countries in future. Overall, the entire thesis study provides guidelines/insights to investors or policy makers for choosing the best solar storage technology in future at a utility scale for a particular country.
Förnybar energi för energiproduktion, liksom Solar, visar sig vara mycket relevant i dagens värld [1]. Det är mycket tydligt att solenergi kommer att framstå som en av de viktigaste energikällorna i framtiden. Dessutom kommer lagringsalternativet att spela en väsentlig roll för den framtida distributionen av solkraftverk. Koncentrerade solkraftverk med värmelagring, solcellsanläggningar integrerade med batterilagring och hybridanläggningar är attraktiva lösningar för att få en stabil och skickbar energiproduktion. Investerare eller beslutsfattare brukar tycka att det är utmanande att komma på den mest genomförbara solcellstekniken eftersom de måste överväga teknikekonomisk genomförbarhet, och samtidigt, ur ett marknads- eller administrativt perspektiv också. Så denna avhandlingsstudie kommer att ta itu med nyckelproblemet som riktar sig till investerare eller beslutsfattare eftersom det finns ett behov av att välja den bästa solenergilagringstekniken på en användningsnivå i framtiden baserat på så många attribut. Avhandlingsprojektet genomfördes i två faser som inkluderar prognosmodellering och uppskattningar och teknikekonomisk bedömning av virtuella anläggningar. Dessa två faser hjälpte till att ta itu med olika frågor i samband med problemstudien i denna studie. Hela avhandlingsstudien omfattade i stort sju länder som sträcker sig över fyra stora regioner runt om i världen. Den första fasen i avhandlingen, prognosmodelleringsuppskattningar visar hur de sju länderna kommer att se ut i framtiden (2020 - 2050) med avseende på installerad kapacitet och kostnader för PV-, CSP- och BESS -teknik. Några viktiga resultat från fas 1 inkluderar, i lågkostnadsuppskattningar, att Kina kommer att vara marknadsledande inom PV och CSP år 2050. I USA och Indien beräknas de installerade kostnaderna för PV minska med 70% år 2050. Av 2050 beräknas de installerade kostnaderna för Solar Tower -teknik sjunka med cirka 65% i Kina och Spanien. I USA kommer priserna på BESS -teknik sannolikt att sjunka med cirka 58 - 60 % år 2050. I den andra fasen av avhandlingsstudien behandlade en teknikekonomisk utvärdering av virtuella anläggningar de aspekter som ska övervägas för ett solprojekt om det används i framtiden i sju specifika länder. Resultaten från denna analys hjälper investerare eller beslutsfattare att välja den billigaste solenergilagringstekniken på en användningsnivå i sju specifika länder i framtiden (2020 - 2050). Viktiga resultat från denna analys visar att i USA, år 2050, kommer PV+BESS att vara den billigaste lagringstekniken på 4 - 10 lagringstimmar. Tillägg av en annan förnybar teknik kommer att öka jämförbarheten. I Kina kommer Hybrid att vara den billigaste lagringstekniken i 4-8 timmar fram till 2050. Det finns en enorm potential för distribution av CSP & hybridanläggningar i framtiden än PV. I Sydafrika kommer CSP att vara den billigaste lagringstekniken år 2050 för 4 - 10 timmars lagring. Det antas att distributionen av BESS -projekt på verktygsnivå börjar från 2025 i Sydafrika. Utöver detta genomfördes marknadskravsanalys som ger insikter speciellt för beslutsfattarna om hur olika drivkrafter och begränsningar påverkar varje solteknik i de specifika länderna i framtiden. Sammantaget ger hela avhandlingsstudien riktlinjer/insikter till investerare eller beslutsfattare för att välja den bästa solenergitekniken i framtiden i en nyttoskala för ett visst land.
APA, Harvard, Vancouver, ISO, and other styles
45

RIBEIRO, JUNIOR JOAQUIM A. "Um estudo simplificado da percepção pública dos benefícios e riscos de centrais termonucleares - sugestões para a comunicação de valor com o público." reponame:Repositório Institucional do IPEN, 2007. http://repositorio.ipen.br:8080/xmlui/handle/123456789/11504.

Full text
Abstract:
Made available in DSpace on 2014-10-09T12:52:37Z (GMT). No. of bitstreams: 0
Made available in DSpace on 2014-10-09T14:02:25Z (GMT). No. of bitstreams: 0
Dissertação (Mestrado)
IPEN/D
Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
APA, Harvard, Vancouver, ISO, and other styles
46

Nahhas, Tamar. "Materials and thermal storage systems by sensible heat for thermodynamic electro-solar plants." Thesis, Perpignan, 2017. http://www.theses.fr/2017PERP0027.

Full text
Abstract:
L'énergie solaire est connue pour sa nature intermittente par rapport aux ressources d’énergie fossile. Cette observation souligne la nécessité d'utilisation d’un système de stockage d'énergie thermique. Le système de stockage thermocline est considéré comme un système de stockage rentable. La présente thèse vise à étudier le potentiel des roches basaltiques et siliceuses comme des candidates matériaux de stockage pour les centrales solaires concentrées. Les études expérimentales des propriétés thermo-physiques et thermomécaniques de ces roches à des températures allant jusqu'à 1000°C montrent que ces roches offrent de bonnes propriétés thermiques par rapport aux matériaux classiques de stockage. L'analyse du système de stockage thermocline sur un lit de roches à air direct est réalisée par une approche numérique. En outre, cette recherche vise également à évaluer l’impact environnementale de ce type de système de stockage en effectuant une analyse comparative de son cycle de vie. Enfin, une étude complémentaire réalisée dans le but de produire une carte d'indice de pertinence a permis d’identifier les zones les plus appropriées pour la construction des centrales solaires en Egypte. L'originalité de cette approche alternative pour le stockage d'énergie thermique est qu’elle combine la performance et la disponibilité des matériaux de stockage tout en réduisant leurs impacts environnementaux et financiers
Compare to fossil fuel energy resources, solar energy is known for its intermittent nature. This observation highlights the need for the use of a thermal energy storage system. The thermocline storage system is considered as a cost-effective storage system. This thesis aims to study the potential of basalt and silex rocks as candidate storage materials for concentrated solar power plants. Experimental studies of the thermo-physical and thermo-mechanical properties of these rocks at temperatures up to 1000°C show that these rocks offer good thermal properties compared with conventional storage materials. The analysis of the thermocline storage system of air rock-packed bed is carried out using a numerical approach. This research also aims to assess the environmental impact of this type of storage system by conducting a comparative analysis of its life cycle. Finally, a complementary study carried out with the aim of producing a relevance index map made it possible to identify the most suitable areas for the construction of solar power plants in Egypt. The originality of this alternative approach for thermal energy storage is that it combines the performance and availability of storage materials while reducing their environmental and financial impacts
APA, Harvard, Vancouver, ISO, and other styles
47

Trahan, Jamie. "A Technical and Economic Comparative Analysis of Sensible and Latent Heat Packed Bed Storage Systems for Concentrating Solar Thermal Power Plants." Scholar Commons, 2015. https://scholarcommons.usf.edu/etd/5598.

Full text
Abstract:
Though economically favorable when compared to other renewable energy storage technologies, thermal energy storage systems for concentrating solar thermal power (CSP) plants require additional cost reduction measures to help transition CSP plants to the point of grid-parity. Thermocline packed bed storage is regarded as one potential low cost solution due to the single tank requirement and low cost storage media. Thus sensible heat storage (SHS) and latent heat storage (LHS) packed bed systems, which are two thermocline varieties, are frequently investigated. LHS systems can be further classified as single phase change material (PCM) systems or cascaded systems wherein multiple PCMs are employed. This study compared the performance of SHS, single PCM, and cascaded PCM direct storage systems under the conditions that may be encountered in utility-scale molten salt CSP plants operating between 565°C and 288°C. A small-scale prototype SHS packed bed system was constructed and operated for use in validating a numerical model. The drawbacks of the latent heat storage process were discussed, and cascaded systems were investigated for their potential in mitigating the issues associated with adopting a single PCM. Several cascaded PCM configurations were evaluated. The study finds that the volume fraction of each PCM and the arrangement of latent heat in a 2-PCM and a 3-PCM system influences the output of the system, both in terms of quality and quantity of energy. In addition to studying systems of hypothetical PCMs, real salt PCM systems were examined and their selection process was discussed. A preliminary economic assessment was conducted to compare the cost of SHS, single-PCM LHS, cascaded LHS, and state-of-the-art 2-tank systems. To the author's knowledge, this is the first study that compares the cost of all three thermocline packed bed systems with the 2-tank design. The SHS system is significantly lower in cost than the remaining systems, however the LHS system does show some economic benefit over the 2-tank design. If LHS systems are to be viable in the future, low cost storage media and encapsulation techniques are necessary.
APA, Harvard, Vancouver, ISO, and other styles
48

Qiu, Bin. "Simulating Thermal and Chemical Spills in Coupled Cooling Reservoirs." Thesis, University of North Texas, 1997. https://digital.library.unt.edu/ark:/67531/metadc279271/.

Full text
Abstract:
Hot water discharges and potential chemical spills are factors that threaten water quality in cooling reservoirs of chemical and power plants. In this thesis, three models are used to analyze the impact of these factors in a particular case study.
APA, Harvard, Vancouver, ISO, and other styles
49

Nuutinen, Antti, and Giovanni Graziano. "Towards Flexible Cogeneration: Techno-economic Optimization of Advanced Combined Cycle Combined Heat and Power Plants integrated with Heat Pumps and Thermal Energy Storage." Thesis, KTH, Energiteknik, 2018. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-235820.

Full text
Abstract:
The liberalization of electricity markets and a growing penetration of renewables is changing operation of electrical grids. The boundary conditions for the operation of conventional power plants are changing and, as such, an improved understanding of the varying loads and prices on the electricity grid is required to assess the performance of emerging combined cycle gas turbine (CCGT) concepts and to further optimize their design for these new markets in the pursuit of increasing their profitability, especially when considering combined heat and power (CHP). To increase the flexibility of CCGT-CHP plants, three new plant layouts have been investigated by integrating different storage concepts and heat pumps in key sections of the traditional plant layout. The present study analyses the influence that market has on determining the optimum CCGT-CHP plant layout that maximizes profits (in terms of plant configuration, sizing and operation strategies) for a given location nearby Turin, Italy, for which hourly electricity and heat prices, as well as meteorological data, have been gathered. A multi-parameter approach for design and operation was followed using KTH’s and EPS’ techno-economic modeling tool DYESOPT. Results are shown by means of a comparative analysis between optimal plants found for each layout and the state-of-the art CCGT-CHP. It is shown that a plant configuration in which a cold storage unit is integrated together with a heat pump at the inlet of the gas turbine unit increases the net present value of the plant by approximately 0.3% when compared against conventional plant layouts. Using the same concept with a heat pump alone can improve lifetime profitability by 1.6%. A layout where district heating supply water is preheated with a combination of a heat pump with hot thermal tank increases plant profitability by up to 0.5%. This work has been performed as part of the PUMP-HEAT project, an EU Horizon 2020 research project in which KTH collaborates with other 13 stakeholders including industry and research institutions. The results will directly influence future work of the project.
APA, Harvard, Vancouver, ISO, and other styles
50

Wong, Anthony Ling Chiung. "Sequestering of CO2 in the oceans around Australia." Thesis, The University of Sydney, 1994. https://hdl.handle.net/2123/26895.

Full text
Abstract:
The increasing threat of C02 to the global warming has prompted many governments to implement strategies to reduce the emission of C02 and other greenhouse gases into the atmosphere. The sequestering of C02 collected from power stations into the ocean is one of the promising strategies which can be used to achieve this goal. The east coast of Australia is identified as a favourable location for the C02 dumping scheme. The location of power stations along the east coast, with its narrow continental shelf, has provided favourable conditions for both the economical construction and running costs, of the ocean C02 disposal scheme. Compared to other oceans in the world, the Tasman Sea, and South Pacific Ocean in general, because of its high concentration of carbonate ions in the water column and sedimentary CaCO3, provides one of the best regions in which neutralisation of C02 can take place. The uncertainties of the fate of C02 after it has been released into the ocean and of its environmental impact are investigated. The current knowledge of C02 dumping schemes are reviewed to identify the most suitable scheme that can be adopted for Australia. It is proposed that an injection of liquid C02 at a depth of 1,000 m would be sufficient to ensure the long-term aim of sequestering the C02 produced in Australia into the ocean as well as minimising the environmental impact to the marine environment. A special release nozzle is needed to allow maximum mixing between the liquid C02 and seawater. The creation of denser COz-enriched plume will allow the anthropogenic C02 collected to sink to greater depths. The aims of creating the sinking current are two. One is to ensure the C02 reaches a greater depth and thus increases the resident time of C02 in the ocean. The other is to allow the C02 to react with sediment CaCO3, which in general is in abundance in the Tasman Sea and the South Pacific Ocean. This neutralisation process will not only reduce the impact of C02 on the environment but also provide a permanent sequestration of C02.
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography