Dissertations / Theses on the topic 'Ocean thermal power plants'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the top 50 dissertations / theses for your research on the topic 'Ocean thermal power plants.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.
Rizea, Steven Emanoel. "Optimization of Ocean Thermal Energy Conversion Power Plants." Master's thesis, University of Central Florida, 2012. http://digital.library.ucf.edu/cdm/ref/collection/ETD/id/5462.
Full textID: 031001365; System requirements: World Wide Web browser and PDF reader.; Mode of access: World Wide Web.; Adviser: Marcel Ilie.; Title from PDF title page (viewed May 8, 2013).; Thesis (M.S.M.E.)--University of Central Florida, 2012.; Includes bibliographical references (p. 77-78).
M.S.M.E.
Masters
Mechanical and Aerospace Engineering
Engineering and Computer Science
Mechanical Engineering; Mechanical Systems
Rodríguez, Buño Mariana. "Near and far field models of external fluid mechanics of Ocean Thermal Energy Conversion (OTEC) power plants." Thesis, Massachusetts Institute of Technology, 2013. http://hdl.handle.net/1721.1/79495.
Full textCataloged from PDF version of thesis.
Includes bibliographical references (p. 126-130).
The world is facing the challenge of finding new renewable sources of energy - first, in response to fossil fuel reserve depletion, and second, to reduce greenhouse gas emissions. Ocean Thermal Energy Conversion (OTEC) can provide renewable energy by making use of the temperature difference between the surface ocean and deep ocean water in a Rankine cycle. An OTEC plant pumps huge volumes of water from the surface and nearly 1 km depth, and releases it at an intermediate depth. The effects of this enormous flux are crucial to understand since disruption of the ambient temperature stratification can affect the efficiency of the plant itself and of adjacent plants. This thesis aims to study the external fluid mechanics of offshore OTEC power plants, to assess their environmental impact and to help analyze whether OTEC plants can provide a sustainable source of energy. Although there has been interest in OTEC for several decades, so far primarily physical and analytical models have been developed. In this study numerical models are developed to model OTEC operating plants: integral models for the near and intermediate field and a large-scale ocean general circulation model. Two strategies in modeling OTEC plant discharge are used to analyze plume dynamics: the "Brute Force" approach, in which a circulation model, MITgcm, computes the near, intermediate and far field mixing; and the "Distributed Sources and Sinks" approach, in which the near and intermediate field are represented in the circulation model by sources and sinks of mass computed by integral models. This study concludes that the Brute Force modeling strategy is highly computationally demanding and sometimes inaccurate. Such simulations are very sensitive to model resolution and may require the use of unrealistic model parameters. The Distributed Sources and Sinks approach was found to be capable of modeling the plume dynamics accurately. This method can be applied to the study of adjacent OTEC power plant interaction, redistribution of nutrients, and propagation of contaminants.
by Mariana Rodríguez Buño.
S.M.
Cottam, P. J. "Innovation in solar thermal chimney power plants." Thesis, University College London (University of London), 2018. http://discovery.ucl.ac.uk/10045417/.
Full textRahmqvist, Elin. "On stochastic unit commitment for thermal power plants." Thesis, KTH, Skolan för elektroteknik och datavetenskap (EECS), 2020. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-285519.
Full textKlimatförändringarna är ett faktum, en kris som hotar varje land, ekonomi och människa.För att förebygga denna kris måste utsläppen av växthusgaser minska dramatiskt. 72 % av de globala utsläppen av växthusgaser år 2016 kom från energiproduktion där värme och elektricitet stod för 42 % av dessa utsläpp. Trots detta växte kolkraften med 28% år 2018 för att kunna möta den ökande efterfrågan på elektricitet. Det är därför av yttersta vikt att dessa resurser används på ett så e↵ektivt sätt som möjligt. En bra och exakt korttidsplanering av kraftsystem kan minska utsläppen och kostnaderna.Målet med denna studie är att implementera stokastisk last i korttidsplaneringen för ett mindre elkraftsystem med 11 enheter. Detta kräver en robust metod som begränsar beräkningstiden för att säkerställa kontinuerlig och säker drift av elkraftsystemet. Analysen måste utvärdera tillförlitligheten, ekonomiska e↵ekterna och beräkningstiden för att lösa det stokastiska korttidsplaneringsproblemet.Ett testsystem har skapats i MATLAB för att utvärdera den stokastiska kontra deterministiska korttidsplaneringsproblemet. Scenarier för det stokastiska korttidsplaneringen har genererats genom att använda en stationär Markov-kedja för att generera felen i lastprognosen och sedan använda Fast Forward Selection metoden för att minska antalet scenarier för att minimera beräkningsinsatsen. Stokastisk korttidsplanering har sedan utvärderats med värdet av den stokastiska lösningen för ekonomisk analys. Sannolikheten för bortkoppling av last samt icke levererad energi har beräknats för att utvärdera tillförlitligheten.En stokastisk metod ger en mer robust lösning men kan vara dyrare vad gäller kostnader. Fem scenarier var det optimala valet för den stokastiska korttidsplaneringsformuleringen. Ö kande av antal scenarier förbättrade inte tillförlitligheten och resulterade i en dyrare lösning. Slutsatsen i detta arbete kan kännas motsägelsefullt då den deterministiska metoden visar på lägre kostnader medans den stokastiska är mer robust. Detta belyser en av utmaningarna i elkraftsystem. Ett mer robust system är vanligtvis dyrare och därför måste aktörerna i systemet bestämma vad som är mest önskvärt i det specifika systemet. Ett mer tillförlitligt men dyrare system eller ett mindre pålitligt och billigaresystem.
Assémat, Céline. "Management of thermal power plants through use values." Thesis, KTH, Elektriska energisystem, 2015. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-175811.
Full textRennie, Eleanor Jane. "Thermal performance of power station cooling towers." Thesis, University of Nottingham, 1992. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.335762.
Full textEl, Khaja Ragheb Mohamad Fawaz. "Solar-thermal hybridization of Advanced Zero Emissions Power Plants." Thesis, Massachusetts Institute of Technology, 2012. http://hdl.handle.net/1721.1/74434.
Full textCataloged from PDF version of thesis.
Includes bibliographical references (p. 43-44).
Carbon Dioxide emissions from power production are believed to have significant contributions to the greenhouse effect and global warming. Alternative energy resources, such as solar radiation, may help abate emissions but suffer from high costs of power production and temporal variations. On the other hand, Carbon Capture and Sequestration allows the continued use of fossil fuels without the CO2 emissions but it comes at an energetic penalty. The Advanced Zero Emissions Plant (AZEP) minimizes this energy loss by making use of Ion Transport Membrane (ITM)-based oxy-combustion to reduce the cost of carbon dioxide separation. This work seeks to assess if there are any thermodynamic gains from hybridizing solar-thermal energy with AZEP. The particular focus is hybridizing of the bottoming cycle with supplemental solar heating. A simple model of parabolic solar trough was used to hybridize a model of the AZEP cycle in ASPEN Plus*. Two cycle configurations are studied: the first uses solar parabolic troughs to indirectly vaporize high pressure steam through Therminol and the second uses parabolic troughs to directly preheat the high pressure water stream prior to vaporization. Simulations of the solar vaporizer hybrid by varying the total area of collectors (holding fuel input constant) show an increase of net electric output from 439MW for the non-hybridized AZEP to 533MW with an input solar share of 38.8%. The incremental solar efficiency is found to be around 16% for solar shares of input ranging from 5% to 38.8%. Moreover, simulations of variable solar insolation for collector area of 550,000 m2 , show that incremental solar efficiency increased with solar insolation reaching a plateau around 17%. Simulations of the direct solar preheater, show a net electric output of 501.3 MW for a solar share of 35%, (an incremental solar efficiency of 13.73%). The power generation and hence incremental efficiency is lower than in hybridization with steam vaporization with the same input solar share. Synergy analysis for the steam vaporization hybrid indicates no thermodynamic gains from hybridization.
by Ragheb Mohamad Fawaz El Khaja.
S.B.
Allen, Kenneth Guy. "Rock bed thermal storage for concentrating solar power plants." Thesis, Stellenbosch : Stellenbosch University, 2014. http://hdl.handle.net/10019.1/86521.
Full textENGLISH ABSTRACT: Concentrating solar power plants are a promising means of generating electricity. However, they are dependent on the sun as a source of energy, and require thermal storage to supply power on demand. At present thermal storage – usually molten salt – although functional, is expensive, and a cheaper solution is desired. It is proposed that sensible heat storage in a packed bed of rock, with air as heat transfer medium, is suitable at temperatures of 500 – 600 °C. To determine if this concept is technically feasible and economically competitive with existing storage, rock properties, packed bed pressure drop and thermal characteristics must be understood. This work addresses these topics. No previously published data is available on thermal cycling resistance of South African rock, and there is limited data from other countries in the proposed temperature range for long-term thermal cycling, so samples were thermally cycled. There is rock which is suitable for thermal storage applications at temperatures of 500 – 600 °C. New maps of South Africa showing where potentially suitable rock is available were produced. Dolerite, found extensively in the Karoo, is particularly suitable. Friction factors were measured for beds of different particles to determine the importance of roughness, shape, and packing arrangement. Five sets of rock were also tested, giving a combined dataset broader than published in any previous study. Limitations of existing correlations are shown. The friction factor is highly dependent on particle shape and, in the case of asymmetric particles, packing method. The friction factor varied by up to 70 % for crushed rock depending on the direction in which it was poured into the test section, probably caused by the orientation of the asymmetric rock relative to the air flow direction. This has not been reported before for rock beds. New isothermal correlations using the volume equivalent particle diameter are given: they are within 15 % of the measurements. This work will allow a techno-economic evaluation of crushed rock beds using more accurate predictions of pumping power than could previously be made. Thermal tests below 80 °C show that bed heat transfer is insensitive to particle shape or type. A heat transfer correlation for air in terms of the volume equivalent diameter was formulated and combined with the E-NTU method. The predicted bed outlet temperatures are within 5 °C of the measurements for tests at 530 °C, showing that the influence of thermal conduction and radiation can be reasonably negligible for a single charge/discharge cycle at mass fluxes around 0.2 kg/m2s. A novel method for finding the optimum particle size and bed length is given: The Biot number is fixed, and the net income (income less bed cost) from a steam cycle supplied by heat from the bed is calculated. A simplified calculation using the method shows that the optimum particle size is approximately 20 mm for bed lengths of 6 – 7 m. Depending on the containment design and cost, the capital cost could be an order of magnitude lower than a nitrate salt system.
AFRIKAANSE OPSOMMING: Gekonsentreerde son-energie kragstasies is n belowende manier om elektrisiteit op te wek, maar hulle is afhanklik van die son as n bron van energie. Om drywing op aanvraag te voorsien moet hulle energie stoor. Tans is termiese stoor – gewoonlik gesmelte sout – hoewel funksioneel, duur, en n goedkoper oplossing word gesoek. Daar word voorgestel dat stoor van voelbare warmte-energie in n gepakte rotsbed met lug as warmteoordrag medium geskik is by temperature van 500 – 600 °C. Om te bepaal of dié konsep tegnies gangbaar en ekonomies mededingend met bestaande stoorstelsels is, moet rotseienskappe, gepakte bed drukval en hitteoordrag verstaan word. Hierdie werk spreek hierdie aspekte aan. Geen voorheen gepubliseerde data is beskikbaar oor die termiese siklus weerstand van Suid-Afrikaanse rots nie, en daar is beperkte data van ander lande in die voorgestelde temperatuurbereik, dus is monsters onderwerp aan termiese siklusse. Daar bestaan rots wat geskik is vir termiese stoor toepassings by temperature van 500 – 600 °C. Nuwe kaarte van Suid-Afrika is opgestel om te wys waar potensieel geskikte rots beskikbaar is. Doleriet, wat wyd in die Karoo voor kom, blyk om veral geskik te wees. Wrywingsfaktore is gemeet vir beddens van verskillende partikels om die belangrikheid van grofheid, vorm en pak-rangskikking te bepaal. Vyf rotsstelle is ook getoets, wat n saamgestelde datastel gee wyer as in enige gepubliseerde studie. Beperkings van bestaande korrelasies word aangetoon. Die wrywingsfaktor is hoogs sensitief vir partikelvorm en, in die geval van asimmetriese partikels, pakkings metode. Die wrywingsfaktor het met tot 70 % gevarieer vir gebreekte rots, afhanklik van die rigting waarin dit in die toetsseksie neergelê is. Dit is waarskynlik veroorsaak deur die oriëntasie van die asimmetriese rots relatief tot die lugvloei rigting, en is nie voorheen vir rotsbeddens gerapporteer nie. Nuwe isotermiese korrelasies wat gebruik maak van die volume-ekwivalente partikel deursnee word gegee: hulle voorspel binne 15 % van die gemete waardes. Hierdie werk sal n tegno-ekonomiese studie van rotsbeddens toelaat wat meer akkurate voorspellings van pompdrywing gebruik as voorheen moontlik was. Termiese toetse onder 80 °C wys dat die warmteoordrag nie baie sensitief is vir partikelvorm en -tipe nie. n Warmte-oordragskorrelasie vir lug in terme van die volume-ekwivalente deursnee is ontwikkel en met die E-NTU-metode gekombineer. Die voorspelde lug uitlaat temperatuur is binne 5 °C van die meting vir toetse by 530 °C. Dit wys dat termiese geleiding en straling redelikerwys buite rekening gelaat kan word vir n enkele laai/ontlaai siklus by massa vloeitempos van omtrent 0.2 kg/m2s. n Oorspronklike metode vir die bepaling van die optimum partikelgrootte en bedlengte word gegee: Die Biot-getal is vas, en die netto inkomste (die inkomste minus die bed omkoste) van n stoomsiklus voorsien met warmte van die bed word bereken. n Vereenvoudigde berekening wat die metode gebruik wys dat die optimum grootte en lengte ongeveer 20 mm en 6-7 m is. Afhangende van die behoueringsontwerp en koste, kan die kapitale koste n orde kleiner wees as dié van n gesmelte nitraatsout stelsel
Allen, Kenneth Guy. "Performance characteristics of packed bed thermal energy storage for solar thermal power plants." Thesis, Stellenbosch : University of Stellenbosch, 2010. http://hdl.handle.net/10019.1/4329.
Full textENGLISH ABSTRACT: Solar energy is by far the greatest energy resource available to generate power. One of the difficulties of using solar energy is that it is not available 24 hours per day - some form of storage is required if electricity generation at night or during cloudy periods is necessary. If a combined cycle power plant is used to obtain higher efficiencies, and reduce the cost of electricity, storage will allow the secondary cycle to operate independently of the primary cycle. This study focuses on the use of packed beds of rock or slag, with air as a heat transfer medium, to store thermal energy in a solar thermal power plant at temperatures sufficiently high for a Rankine steam cycle. Experimental tests were done in a packed bed test section to determine the validity of existing equations and models for predicting the pressure drop and fluid temperatures during charging and discharging. Three different sets of rocks were tested, and the average size, specific heat capacity and density of each set were measured. Rock and slag samples were also thermally cycled between average temperatures of 30 ºC and 510 ºC in an oven. The classical pressure drop equation significantly under-predicts the pressure drop at particle Reynolds numbers lower than 3500. It appears that the pressure drop through a packed bed is proportional to the 1.8th power of the air flow speed at particle Reynolds numbers above about 500. The Effectiveness-NTU model combined with a variety of heat transfer correlations is able to predict the air temperature trend over the bed within 15 % of the measured temperature drop over the packed bed. Dolerite and granite rocks were also thermally cycled 125 times in an oven without breaking apart, and may be suitable for use as thermal storage media at temperatures of approximately 500 ºC. The required volume of a packed bed of 0.1 m particles to store the thermal energy from the exhaust of a 100 MWe gas turbine operating for 8 hours is predicted to be 24 × 103 m3, which should be sufficient to run a 25-30 MWe steam cycle for over 10 hours. This storage volume is of a similar magnitude to existing molten salt thermal storage.
AFRIKAANSE OPSOMMING: Sonenergie is die grootste energiebron wat gebruik kan word vir krag opwekking. ‘n Probleem met die gebruik van sonenergie is dat die son nie 24 uur per dag skyn nie. Dit is dus nodig om die energie te stoor indien dit nodig sal wees om elektrisiteit te genereer wanneer die son nie skyn nie. ‘n Gekombineerde kringloop kan gebruik word om ‘n hoër benuttingsgraad te bereik en elektrisiteit goedkoper te maak. Dit sal dan moontlik wees om die termiese energie uit die primêre kringloop te stoor, wat die sekondêre kringloop onafhanklik van die primêre kringloop sal maak. Dié gevalle studie ondersoek die gebruik van ‘n slakof- klipbed met lug as hitteoordragmedium, om te bepaal of dit moontlik is om hitte te stoor teen ‘n temperatuur wat hoog genoeg is om ‘n Rankine stoom kringloop te bedryf. Eksperimentele toetse is in ‘n toets-bed gedoen en die drukverandering oor die bed en die lug temperatuur is gemeet en vergelyk met voorspelde waardes van vergelykings en modelle in die literatuur. Drie soorte klippe was getoets. Die gemiddelde grootte, spesifieke hitte-kapasiteit en digtheid van elke soort klip is gemeet. Klip en slak monsters is ook siklies tussen temperature van 30 ºC en 510 ºC verkoel en verhit. Die klassieke drukverlies vergelyking gee laer waardes as wat gemeet is vir Reynolds nommers minder as 3500. Dit blyk dat die drukverlies deur ‘n klipbed afhanklik is van die lug vloeispoed tot die mag 1.8 as die Reynolds nommer groter as omtrent 500 is. Die ‘Effectiveness-NTU’ model gekombineerd met ‘n verskeidenheid van hitteoordragskoeffisiënte voorspel temperature binne 15 % van die gemete temperatuur verskil oor die bed. Doloriet en graniet klippe het 125 sikliese toetse ondergaan sonder om te breek, en is miskien gepas vir gebruik in ‘n klipbed by temperature van sowat 500 ºC Die voorspelde volume van ‘n klipbed wat uit 0.1 m klippe bestaan wat die termiese energie vir 8 ure uit die uitlaat van ‘n 100 MWe gasturbiene kan stoor, is 24 × 103 m3. Dit behoort genoeg te wees om ‘n 25 – 30 MWe stoom kringloop vir ten minste 10 ure te bedryf. Die volume is min of meer gelyk aan dié van gesmelte sout store wat alreeds gebou is.
Darwish, Mazen. "Modular Hybridization of Solar Thermal Power Plants For Developing Nations." Thesis, KTH, Kraft- och värmeteknologi, 2012. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-104456.
Full textEdwards, Jacob N. "Thermal energy storage for nuclear power applications." Thesis, Kansas State University, 2017. http://hdl.handle.net/2097/36238.
Full textDepartment of Mechanical and Nuclear Engineering
Hitesh Bindra
Storing excess thermal energy in a storage media that can later be extracted during peak-load times is one of the better economical options for nuclear power in future. Thermal energy storage integration with light water-cooled and advanced nuclear power plants is analyzed to assess technical feasibility of different storage media options. Various choices are considered in this study; molten salts, synthetic heat transfer fluids, and packed beds of solid rocks or ceramics. In-depth quantitative assessment of these integration possibilities are then analyzed using exergy analysis and energy density models. The exergy efficiency of thermal energy storage systems is quantified based on second law thermodynamics. The packed bed of solid rocks is identified as one of the only options which can be integrated with upcoming small modular reactors. Directly storing thermal energy from saturated steam into packed bed of rocks is a very complex physical process due to phase transformation, two phase flow in irregular geometries and percolating irregular condensate flow. In order to examine the integrated physical aspects of this process, the energy transport during direct steam injection and condensation in the dry cold randomly packed bed of spherical alumina particles was experimentally and theoretically studied. This experimental setup ensures controlled condensation process without introducing significant changes in the thermal state or material characteristics of heat sink. Steam fronts at different flow rates were introduced in a cylindrical packed bed and thermal response of the media was observed. The governing heat transfer modes in the media are completely dependent upon the rate of steam injection into the system. A distinct differentiation between the effects of heat conduction and advection in the bed were observed with slower steam injection rates. A phenomenological semi-analytical model is developed for predicting quantitative thermal behavior of the packed bed and understanding physics. The semi-analytical model results are compared with the experimental data for the validation purposes. The steam condensation process in packed beds is very stable under all circumstances and there is no effect of flow fluctuations on thermal stratification in packed beds. With these experimental and analytical studies, it can be concluded that packed beds have potential for thermal storage applications with steam as heat transfer fluid. The stable stratification and condensation process in packed beds led to design of a novel passive safety heat removal system for advanced boiling water reactors.
Miranda, Gilda. "Dispatch Optimizer for Concentrated Solar Power Plants." Thesis, Uppsala universitet, Byggteknik och byggd miljö, 2020. http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-402436.
Full textPalu, Ivo. "Impact of wind parks on power system containing thermal power plants = Tuuleparkide mõju soojuselektrijaamadega energiasüsteemile /." Tallinn : TUI Press, 2009. http://digi.lib.ttu.ee/i/?443.
Full textFernandez-Munoz, Raul. "Design of solar power plant with coupled thermal storage." Thesis, Georgia Institute of Technology, 1996. http://hdl.handle.net/1853/16722.
Full textNASCIMENTO, WALLACE JOSE DAMASCENO DO. "BIFUEL CONVERSION OF THERMAL POWER PLANTS UNDER UNCERTAINTY: A REAL OPTIONS APPROACH." PONTIFÍCIA UNIVERSIDADE CATÓLICA DO RIO DE JANEIRO, 2008. http://www.maxwell.vrac.puc-rio.br/Busca_etds.php?strSecao=resultado&nrSeq=13379@1.
Full textNo Brasil, apesar da predominência da participação de usinas hidrelétricas no parque gerador, há alguns anos, devido ao Programa Prioritário de Termeletricidade (PPT), foram implantadas diversas centrais termelétricas movidas a Gás Natural. Muitas são as incertezas apresentadas aos agentes do Setor de Energia Elétrica no Brasil, e mais um risco tem ameaçado estas usinas: a oferta de Gás Natural. A conversão das usinas para bicombustível, possibilitando a utilização de Óleo Diesel como combustível alternativo, surgiu como opção para eliminar este risco. Face às diversas incertezas apresentadas, as técnicas tradicionais de análise econômico-financeira se mostram limitadas para avaliar este investimento e as flexibilidades operacionais, sendo proposto que estas avaliações sejam feitas a partir da Teoria de Opções Reais, que consegue tratar as incertezas e flexibilidades mais adequadamente. As opções operacionais (gerar com Gás Natural ou com Diesel) podem ser vistas como uma seqüência de opções européias de compra (European call option), considerando a conversão como uma opção de mudança de insumo (switch-input Real Option) oferecida ao agente proprietário da usina. O objetivo maior deste trabalho é valorar esta opção para uma térmica instalada no subsistema Sudeste do Brasil, indicando, para cada caso, o prêmio que o agente estaria disposto a pagar pela tecnologia de conversão. Como método de avaliação, são utilizadas Simulações de Monte Carlo, a partir do modelo proposto de remuneração da usina, com as variáveis e incertezas associadas: níveis de despacho e contratação, preço do contrato e preço spot da energia elétrica, considerando que os custos variáveis unitários de geração (custos dos combustíveis) futuros seguem um processo estocástico de Movimento Geométrico Browniano (MGB), além da possível penalidade paga pela usina a ANEEL no caso de ser chamada a despacho pelo ONS e não gerar por falta de combustível. Por fim, algumas análises de sensibilidade são apresentadas.
In Brazil, despite the predominant participation of hydro power plants, some years ago, due to Thermo Power Priority Program (PPT), a large number of Natural Gaspowered plants were implanted. A lot of uncertainties are imposed to the players in the Brazilian Power Market, and one more risk arises: the Natural Gas offer. The bi-fuel conversion arises as an option to rule out this risk, since it allows the use of diesel as alternative fuel to the plant. Because of the many uncertainties presented, traditional techniques of economics and financial analysis are limited to value this investment and its operational flexibilities. Real Options Theory is proposed to value this investment, since it is able to deal more appropriately with the uncertainties and flexibilities. Operational options can be seen as a sequence of European Call Options, considering the conversion as a Switch-Input Real Option offered to the Thermo Power Plant’s owner. The main objective of this paper is to increase this option’s value, to a plant located in the Brazilian Southeast Subsystem, indicating in each case, the premium that the player would be willing to pay for the conversion technology. Monte Carlo Simulation was used as a valuation method, for the plant’s cash-flow model, considering the following variables and uncertainties: dispatch and contract level, contract energy and spot prices. Fuel costs are assumed to follow a Brownian Geometric Motion. The possibility of payment of fines to the Eletricity Regulatory Agency (ANEEL) in case of the power plant be dispatch by the Brazilian ISO (ONS) and not delivery energy to the system because of fuel constraints is also considered. Finally, we present sensitivity analysis.
Dawson, Karen Margaret. "Advanced thermal hydraulic simulations for human reliability assessment of nuclear power plants." Thesis, Massachusetts Institute of Technology, 2017. http://hdl.handle.net/1721.1/112392.
Full textThis electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.
Cataloged from student-submitted PDF version of thesis.
Includes bibliographical references (pages 101-102).
Human Risk Assessment (HRA) in the nuclear power industry has advanced in the last two decades. However, there is a lack of understanding of the magnitude of the effect of thermal hydraulic (TH) uncertainties upon the failure probabilities of the operator actions of nuclear units. I demonstrate in this work that there is an effect of TH uncertainties on the operating crew's probability of recognizing errors during a loss of coolant accident (LOCA) initiating event. The magnitude of the effect of the TH uncertainty on the operator's ability to recognize errors is dependent upon the size of the break, the operating state of the plant (in operation or shutting down), and the error that is committed. I utilized an uncertainty software, Dakota, coupled with an advanced TH software, MAAP4, to perform a Monte Carlo analysis to propagate selected TH uncertainties through a LOCA initiating event in which the automatic safety coolant injection system fails to automatically actuate. The operator mission is to manually actuate the safety coolant injection system. Two errors that the operating crew could make are 1) entering fire procedures and 2) testing for saturation of the primary system before the saturation occurs. I calculate the operator failure probabilities using the MERMOS HRA methodology (used by the French electric utility company Electricité de France, EdF). My results show a reduction in scenario failure probability from the values reported by EdF in its published MERMOS Catalogue of more than 80% for the operator recognizing the the error in entering fire procedures. For the error in testing for saturation of the primary system before saturation occurs, I calculated a scenario failure probability in Mode B of 0.0033, while the MERMOS Catalogue listed the scenario failure probability as negligible. My results show that there is an effect from TH uncertainties on operator failure probabilities. This research provides a method of improving the accuracy of failure probabilities in established HRA methodologies using TH simulations.
by Karen Margaret Dawson.
S.M.
Memon, Ejaz. "Environmental effects of thermal power plant emissions : a case study /." Thesis, National Library of Canada = Bibliothèque nationale du Canada, 2000. http://www.collectionscanada.ca/obj/s4/f2/dsk1/tape4/PQDD_0016/MQ55524.pdf.
Full textSpelling, James. "Hybrid Solar Gas-Turbine Power Plants : A Thermoeconomic Analysis." Doctoral thesis, KTH, Kraft- och värmeteknologi, 2013. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-121315.
Full textHållbar energiförsörjning är för närvarande en av de viktigaste frågorna förmänskligheten. Koncentrerad solenergi är nu etablerad som en tillförlitlig källaav förnybar energi. Den reglerbara karaktären hos tekniken gör den specielltintressant för uppbyggnaden av ett framtida koldioxidsnålt elsystem.Kostnaden för elektricitet från nuvarande termiska solkraftverk är hög trottsflera decennier av utveckling. Ett genombrått på tekniknivå krävs för att drivaned kostnaderna. Sol-gasturbiner är ett av de mest lovande alternativen, somger en ökad verkningsgrad samtidigt som vattenkonsumtionen reducerasdrastiskt. Sol-gasturbintekniken gör det möjligt att blandköra solenergi ochandra bränslen för att möta efterfrågan vid alla tidpunkter, en attraktiv aspekt iförhållande till alternativa lösningar.Uppbyggnaden av första generationens kommersiella hybrida solgasturbinkraftverkförsvåras dock av bristen på etablerade och standardiseradekraftverkskonfigurationer. Dessa ger planeraren ett stort antal valmöjlighetersom underlag för beslutsfattande. Termoekonomiska studier har genomförtsför ett flertal olika kraftverkskonfigurationer, däribland kraftverk med enkelcykel, kombikraftverk samt möjligheten att utnyttja termisk energilagring.Pareto-optimala konfigurationer har identifierats med hjälp av multiobjektsoptimeringför att belysa balansen mellan kostnader och utsläpp.Analysen av det enkla hybrida sol-gasturbinkraftverket visade attelektricitetskostnaden hållits på en låg nivå, men att den möjliga minskningen avkoldioxidutsläpp är relativt liten. Dessutom identifierades en inre balans mellanatt bibehålla en hög verkningsgrad hos konfigurationen och en hög andelsolenergi i produktionen. Andelen av solenergi i gasturbinen överskred aldrig63% på årlig bas, även med optimerade kraftverkskonfigurationer.Två förbättringar föreslås för att övervinna begränsningarna hos kraftverk medenkel cykel: integration av termisk energilagring samt nyttjande avkombikraftverkskonfigurationer. Termisk energilagring tillåter en ökad andelsolenergi i driften och reducerar koldioxidutsläppen drastiskt, medan denytterligare cykeln hos kombikraftverket reducerar elektricitetskostnaden.Kombinationen av dessa förbättringar ger den bästa prestandan, med enreduktion av koldioxidutsläppen på upp till 34% och reducerade elektricitetskostnaderpå upp till 22% i jämförelse med andra kombinationer avkonventionella kraftverkskonfigurationer.
QC 20130503
Kretzschmar, Holger. "The Hybrid Pressurized Air Receiver (HPAR) for combined cycle solar thermal power plants." Thesis, Stellenbosch : Stellenbosch University, 2014. http://hdl.handle.net/10019.1/86377.
Full textENGLISH ABSTRACT: Concentrating solar power technology is a modern power generation technology in which central receiver systems play a significant role. For this technology a field of heliostats is used to reflect solar irradiation to the receiver located on top of the tower. An extensive review has shown that contemporary receiver designs face geometric complexities, lack of thermal efficiency as well as issues with durability and cost. The purpose of this study is to develop a new receiver concept that can potentially reduce these issues. A parametric analysis was used to identify potential means of improvement based on an energy balance approach including sensitivities involved with convection and radiation heat transfer. Design criteria such as the use of headers to minimize pressure drop was also investigated. Based on these findings the hybrid pressurized air receiver was developed which is a combination of tubular and volumetric receiver technologies. The fundamental idea of the receiver was investigated by simulating the ray-tracing and coupled natural convection and radiation heat transfer. The ray-tracing results have shown that the use of quartz glass is a prospective solution to higher allowable flux densities, but with reflection losses in the order of 7 %. The coupled natural convection heat transfer simulation further revealed that the receiver concept effectively eliminates the escape of buoyant plumes and radiative heat losses are minimized. Empirical data was gathered from a medium flux concentrator and good agreement with the numerical results was obtained. The thesis therefore concludes that the research outcomes were met. Ongoing research aims to optimise the receiver concept for a 5MW pilot plant.
AFRIKAANSE OPSOMMING: Gekonsentreerde sonkrag tegnologie is ’n moderne kragopwekkingstegnologie waar sentrale ontvangersisteme ’n beduidende rol speel. Vir hierdie tegnologie word ’n veld heliostate gebruik om sonstraling na die ontvanger wat aan die bopunt van die toring geleë is te reflekteer. ’n Omvattende hersiening het daarop gewys dat kontemporêre ontwerpe van die ontvangers ’n aantal geometriese kompleksiteite, ’n tekort aan termiese doeltreffendheid sowel as probleme in terme van duursaamheid en koste in die gesig staar. Die doel van die studie is om ’n nuwe ontvangerskonsep te ontwikkel wat moontlik hierdie probleme kan verminder. ’n Parametriese analise is gebruik om potensiële maniere van verbetering aan te dui wat gebaseer is op ’n energiebalans benadering; insluitend sensitiwiteite betrokke by konvektiewe en stralingswarmteoordrag. Ontwerpkriteria soos die gebruik van spruitstukke om drukverliese te minimaliseer is ook ondersoek. Gebaseer op hierdie bevindinge is die hibriede saamgepersde-lug ontvanger ontwikkel. Laasgenoemde is ’n kombinasie van buis- en volumetriese ontvangertegnologie. Die fundamentele idee van die ontvanger is ondersoek deur straalberekening asook die gelyktydige natuurlike konveksie en stralingswarmteoordrag te simuleer. Die straalberekeningsresultate het getoon dat die gebruik van kwarts glas ’n moontlike oplossing is om hoër stralingsintensiteit te bereik, maar met refleksieverliese in die orde van 7 %. Die gelyktydige natuurlike konveksie en stralingswarmteoordrag simulasie het verder aan die lig gebring dat die ontvangerkonsep die ontsnapping
Wagner, Sharon J. "Environmental and Economic Implications of Thermal Energy Storage for Concentrated Solar Power Plants." Research Showcase @ CMU, 2011. http://repository.cmu.edu/dissertations/682.
Full textNixon, Jonathan. "Solar thermal collectors for use in hybrid solar-biomass power plants in India." Thesis, Aston University, 2012. http://publications.aston.ac.uk/18722/.
Full textGeorge, K. V. "Source apportionment of particulate matter pollution around a pit head thermal power station." Thesis, IIT Delhi, 2016. http://localhost:8080/iit/handle/2074/7042.
Full textJones, I. D. "Assessment and design of small-scale hydro-electric power plants." Thesis, University of Salford, 1988. http://usir.salford.ac.uk/2212/.
Full textBanerjee, S. "Ocean energy assessment : an integrated methodology." Thesis, Coventry University, 2011. http://curve.coventry.ac.uk/open/items/16196d0d-e671-489a-ba71-f20cdb6c8df3/1.
Full textWilliams, Daniel David. "Cold side thermal energy storage system for improved operation of air cooled power plants." Thesis, Massachusetts Institute of Technology, 2012. http://hdl.handle.net/1721.1/78194.
Full textCataloged from PDF version of thesis.
Includes bibliographical references (p. 81-82).
Air cooled power plants experience significant performance fluctuations as plant cooling capacity reduces due to higher daytime temperature than nighttime temperature. The purpose of this thesis is to simulate the detailed operation of a cold side thermal energy storage system in order to evaluate its potential. An organic Rankine cycle geothermal power station is used as an example application. Detailed sizing and operation considerations are discussed. Several representative case studies compare the performance of candidate configurations. Operation of the selected configuration is then simulated for a full year and a proposed integration of the system with existing plant hardware is laid out. A correlation between weather trends and production is outlined. Finally an economic cost/benefit analysis performed to determine the payback period for implementing the proposed system. The cold side TES system is shown to shift substantial power generation capability from nighttime to daytime when electrical demand is highest, especially during hot summer months. For example, daily energy production is shown to increase by up to 18% under particularly favorable conditions. This redistribution of the power generation curve is accomplished with less than a 5% reduction in overall annual energy production in Mega-Watt hours. The system is shown to be more effective at shifting power generation capacity during warmer months than cooler months. The reduced day to night temperature fluctuation during cooler months results in a reduced thermal storage benefit under similar parasitic loads. The economic benefits of this system are dependent upon the on-peak vs off-peak electricity prices. Economic analysis using 2011 transient price data from the U.S. Midwest Region results in a small increase in annual income. The increased income from the proposed cold side TES system is found to be insufficient to outweigh the required capital investment at current electricity prices.
by Daniel David Williams.
S.M.
Gil-García, Álvaro Antonio. "Thermodynamic behaviour of supercritical water as working fluid in advanced coal-fired power plants : simulation and design study." Thesis, University of Birmingham, 2017. http://etheses.bham.ac.uk//id/eprint/7734/.
Full textRawat, Anubhav. "Flow characteristics of high concentration fly ash slurries through pipelines." Thesis, IIT Delhi, 2016. http://localhost:8080/xmlui/handle/12345678/7100.
Full textHoward, Dustin F. "Modeling, simulation, and analysis of grid connected dish-stirling solar power plants." Thesis, Georgia Institute of Technology, 2010. http://hdl.handle.net/1853/34832.
Full textRuiz-Cabañas, F. Javier. "Corrosion evaluation of molten salts thermal energy storage (TES) systems in concentrated solar power plants (CSP)." Doctoral thesis, Universitat de Lleida, 2020. http://hdl.handle.net/10803/671680.
Full textEl creciente protagonismo de la tecnología solar se centra en su capacidad para adaptar su producción a la demanda energética exigida. La gestionabilidad de este tipo de centrales se ha conseguido mediante la integración de sistemas de almacenamiento térmico en sales fundidas. El uso de sales fundidas en sistemas de almacenamiento térmico presenta el hándicap de su corrosividad a alta temperatura. El primer bloque de la Tesis analiza los fenómenos de corrosión asociados a las sales solares en la planta piloto TES-PS10 mediante la instalación de racks de corrosión en los tanques de sales. Además, se ha llevado a cabo un estudio post-mortem de componentes de la instalación. Finalmente, se ha analizado a nivel de laboratorio la corrosividad de distintas mezclas de nitrato de baja pureza. El segundo bloque de la tesis se centra en los sistemas de almacenamiento en calor latente. En concreto, se analiza la corrosión asociada a la mezcla peritéctica 46% LiOH-54% KOH propuesta como material de cambio de fase en el módulo de evaporación en plantas de generación directa de vapor. De este modo, se han llevado a cabo ensayos de corrosión a nivel de laboratorio para evaluar el comportamiento a corrosión de distintos materiales en contacto con los hidróxidos.
The growing of concentrated solar power (CSP) within the different renewable energies is due to its ability to adapt the production to the required energy demand. The dispatchability of this type of plants has been achieved through the integration of molten salts thermal storage systems (TES). Molten salts have a handicap associated to their corrosiveness at high temperature. First block of this Thesis analyzes the corrosion phenomena associated with solar salts used in TES-PS10 pilot plant by installing corrosion racks in the salt tanks. Moreover, a postmortem study of different components was performed after facility shut down. Finally, in order to reduce the cost of the salt inventory in TES systems, the corrosivity of different low purity nitrates mixtures has been analyzed at laboratory scale. The second block of the Thesis focuses on latent heat storage systems. Specifically, it has been analyzed the corrosion associated with the proposed 46% LiOH-54% KOH peritectic mixture as a phase change material in the evaporation module of direct steam generation (DSG) CSP plants. Thus, corrosion tests have been performed at laboratory level to evaluate the corrosion performance of several materials in contact with such hydroxides.
Otgonbaatar, Uuganbayar. "Methodology for characterization of representativeness uncertainty in performance indicator measurements of thermal and nuclear power plants." Thesis, Massachusetts Institute of Technology, 2016. http://hdl.handle.net/1721.1/107279.
Full textThis electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.
Cataloged from student-submitted PDF version of thesis.
Includes bibliographical references (pages 327-331).
In this thesis, a general Methodology framework to characterize, assess and quantify the representativeness uncertainty in performance indicator measurements in thermal and nuclear plants is presented. The representativeness uncertainty arises from the inherent heterogeneity or the variability of the quantity being measured or from the inadequacy of the physical models used to simulate the measurement. The main objective of the Methodology is to gain a deeper physical understanding of the Representativeness uncertainty of the measurement by using numerical simulation tools such as Computational Fluid Dynamics (CFD) and to quantify various sources of representativeness uncertainty. First, the components of the Methodology are expressed using the normal probability distribution for the uncertainty sources. Second, a non-parametric formulation of the Methodology framework is developed and demonstrated. The use of non-parametric techniques allows the quantification and integration of uncertainties that are not expressed by the normal probability distribution. The Methodology is developed based on the analysis of four industrial Case Studies involving uncertainties in performance indicator measurements to structure the analysis. They are: Mass flow rate measurement by an orifice plate (Case Study 1), Steam Generator recirculation ratio measurement using chemical tracers (Case Study 2), The simulation of cooling tower deformation using a Photomodeler (Case Study 3) and the NOx emission measurement from a Combined Cycle Gas Turbine (Case Study 4). In Case Study 1, the non-parametric bootstrap method was used to quantify sampling, iterative and discretization uncertainties thus demonstrating its applicability to CFD uncertainty analysis. In Case Studies 2,3 and 4, the parametric formulation of the Methodology is used to structure the technical analysis.
by Uuganbayar Otgonbaatar.
Ph. D.
Анкудинов, А. А., В. А. Васин, Л. А. Ермилов, and Б. Б. Пайчадзе. "Опыт ОАО КТЗ в разработке и эксплуатации насосов для тепловых электростанций." Thesis, Изд-во СумГУ, 2002. http://essuir.sumdu.edu.ua/handle/123456789/21247.
Full textBruce, Robert Alasdair Wilson. "Impacts of variable renewable generation on thermal power plant operating regimes." Thesis, University of Edinburgh, 2016. http://hdl.handle.net/1842/20387.
Full textManente, Giovanni. "Analysis and Development of Innovative Binary Cycle Power Plants for Geothermal and Combined Geo-Solar Thermal Resources." Doctoral thesis, Università degli studi di Padova, 2011. http://hdl.handle.net/11577/3421590.
Full textLa tesi analizza gli impianti a ciclo binario (Organic Rankine Cycles) per generazione di elettricità da risorse geotermiche a bassa entalpia. L'obiettivo è la massimizzazione della potenza netta tramite una selezione appropriata del fluido operativo e dei parametri di ciclo. La valutazione critica di molti studi sui cicli di Rankine organici ha fornito le basi per formulare uno studio di ottimizzazione avente come funzione obiettivo il rendimento di recupero exergetico. Sono analizzati due fluidi operativi considerando sia pressioni supercritiche che subcritiche e diverse temperature del fluido geotermico. L'applicazione di tecniche avanzate derivate dalla Pinch Analysis (metodo HEATSEP) ha consentito di trovare anche soluzioni sub-ottimali, corrispondenti a piccoli scostamenti dei parametri di ciclo dai valori di progetto ottimali. Queste soluzioni, sebbene sub-ottimali da un punto di vista termodinamico, potrebbero essere scelte se venissero considerati anche aspetti legati alla tecnologia, economia, flessibilità o sicurezza del sistema. I costi delle soluzioni termodinamicamente ottimali sono quindi valutati mostrando l'impatto della temperatura del fluido geotermico e della scelta del fluido operativo sull'economia del sistema. I risultati di questo studio sono applicati all'impianto reale a ciclo binario di Stillwater che iniziò l'operazione nel 2009 in Nevada (USA). L'impianto opera a pressioni subcritiche con isobutano come fluido operativo e usa un sistema di raffreddamento ad aria. A causa della limitata risorsa geotermica la potenza netta prodotta dall'impianto è molto più bassa di quella attesa. E' stato sviluppato un modello dettagliato di fuori progetto dell'impianto usando il software Aspen. Il modello è stato validato con i dati dell'impianto raccolti nel primo anno di attività. Dopo validazione il modello è utilizzato per ottenere i parametri operativi che massimizzano la produzione energetica annuale. E' stato quindi effettuato uno studio per aumentare le prestazioni dell'impianto geotermico di Stillwater con l'aggiunta della risorsa solare. I parametri di ciclo sono ottimizzati per valori differenti della temperatura ambiente e della radiazione solare per massimizzare la produzione energetica annuale. Sono confrontate due configurazioni di ciclo ibrido, con e senza accumulo, ed è calcolato il costo dell'energia elettrica (LCOE). Come atteso, questo LCOE è abbastanza elevato a causa dei costi elevati dei collettori solari e potrebbe essere competitivo solo in presenza di incentivi appropriati.
Guédez, Rafael. "A Techno-Economic Framework for the Analysis of Concentrating Solar Power Plants with Storage." Doctoral thesis, KTH, Kraft- och värmeteknologi, 2016. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-191339.
Full textKoncentrerad solkraft erbjuder möjligheten att integrera kostnadseffektiv termisk energilagring och därmed behovsstyrd kraftkontroll. Detta är en viktig fördel jämfört med andra förnybara energiteknologier. Lagringsintegration tillåter solkraftsanläggningar att öka sin lastfaktor och skifta produktion till tider med största efterfrågan. Vidare möjliggör lagring fast elproduktion vilket leder till förbättrad nät- och kraftturbinstabilitet. Därför kan termisk lagring öka anläggningsprestanda och ekonomiskt värde trots ökande initiala kapitalkostnader. I termer av specifik elproduktionskostnad (LCOE) ligger koncentrerade solkraftsanläggningar med lagring fortfarande högre än andra kraftteknologier och anläggningsprojekt blir endast lönsamma genom subventionsmodeller eller teknologispecifika konkurrensutsatta anbudsförfaranden. Att hitta adekvata policylösningar och optimala design och operationsstrategier är en utmanande process eftersom det gäller att hitta rätt balans mellan variabel solinstrålning, lagring av energi och tid för produktion genom optimal design och operation av solmottagarfält, kraftblock och lagringskapacitet. I denna avhandling presenteras en omfattande metodik för pre-design och analys av koncentrerande solkraftverk. Metodiken baseras på en tekno-ekonomisk modelleringsansats som möjliggör identifiering av optimala avvägningssamband för tekniska, ekonomiska och miljöprestanda indikatorer. Metodiken tillämpas på ett antal moderna anläggningslayouter och lagrings- och hybridiseringskoncept för att identifiera optimal kraftanläggningsdesign i termer av komponentprestanda och lagringsanvändningsstrategier. I slutsatsen poängteras relevansen av att hitta rätt storlek på nyckelkomponenter i relation till lagringsstrategi och randvillkoren som ges av konstruktionsläget för optimal ekonomisk och miljömässig prestanda. Resultaten används för att formulera rekommendationer till nyckelaktörer i beslutsprocessen genom hela kraftanläggningens värdekedja från politisk beslutsfattare till anläggningsingenjör. Forskningen och slutsatserna i detta arbete skall i första hand ta ett steg framåt för optimering och design av solkraftsanläggningar men även tillhandahålla en metodik för utvärdering av lagringslösningar och dess specifika värde för solkraftsanläggningar och elnätet.
QC 20160829
Richter, Pascal [Verfasser], Martin Akademischer Betreuer] Frank, Siegfried [Akademischer Betreuer] [Müller, and Diaz Manuel J. [Akademischer Betreuer] Castro. "Simulation and optimization of solar thermal power plants / Pascal Richter ; Martin Frank, Siegfried Müller, Manuel J. Castro Diaz." Aachen : Universitätsbibliothek der RWTH Aachen, 2017. http://d-nb.info/1162498692/34.
Full textBachelier, Camille [Verfasser], and R. [Akademischer Betreuer] Stieglitz. "Techno-economical analyses of linear solar thermal electric plants for dispatchable power generation / Camille Bachelier ; Betreuer: R. Stieglitz." Karlsruhe : KIT-Bibliothek, 2021. http://d-nb.info/1238148115/34.
Full textRader, Jordan D. "Loss of normal feedwater ATWS for Vogtle Electric Generating Plant using RETRAN-02." Thesis, Atlanta, Ga. : Georgia Institute of Technology, 2009. http://hdl.handle.net/1853/31741.
Full textCommittee Chair: Abdel-Khalik, Said I.; Committee Member: Ghiaasiaan, S. Mostafa; Committee Member: Hertel, Nolan E. Part of the SMARTech Electronic Thesis and Dissertation Collection.
Ehtiwesh, Ismael Alagili Sassi. "Exergetic, energetic, economic and environmental evaluation of concentrated solar power plants in Libya." Doctoral thesis, Universidade de Aveiro, 2016. http://hdl.handle.net/10773/15882.
Full textThe PhD project addresses the potential of using concentrating solar power (CSP) plants as a viable alternative energy producing system in Libya. Exergetic, energetic, economic and environmental analyses are carried out for a particular type of CSP plants. The study, although it aims a particular type of CSP plant – 50 MW parabolic trough-CSP plant, it is sufficiently general to be applied to other configurations. The novelty of the study, in addition to modeling and analyzing the selected configuration, lies in the use of a state-of-the-art exergetic analysis combined with the Life Cycle Assessment (LCA). The modeling and simulation of the plant is carried out in chapter three and they are conducted into two parts, namely: power cycle and solar field. The computer model developed for the analysis of the plant is based on algebraic equations describing the power cycle and the solar field. The model was solved using the Engineering Equation Solver (EES) software; and is designed to define the properties at each state point of the plant and then, sequentially, to determine energy, efficiency and irreversibility for each component. The developed model has the potential of using in the preliminary design of CSPs and, in particular, for the configuration of the solar field based on existing commercial plants. Moreover, it has the ability of analyzing the energetic, economic and environmental feasibility of using CSPs in different regions of the world, which is illustrated for the Libyan region in this study. The overall feasibility scenario is completed through an hourly analysis on an annual basis in chapter Four. This analysis allows the comparison of different systems and, eventually, a particular selection, and it includes both the economic and energetic components using the “greenius” software. The analysis also examined the impact of project financing and incentives on the cost of energy. The main technological finding of this analysis is higher performance and lower levelized cost of electricity (LCE) for Libya as compared to Southern Europe (Spain). Therefore, Libya has the potential of becoming attractive for the establishment of CSPs in its territory and, in this way, to facilitate the target of several European initiatives that aim to import electricity generated by renewable sources from North African and Middle East countries. The analysis is presented a brief review of the current cost of energy and the potential of reducing the cost from parabolic trough- CSP plant. Exergetic and environmental life cycle assessment analyses are conducted for the selected plant in chapter Five; the objectives are 1) to assess the environmental impact and cost, in terms of exergy of the life cycle of the plant; 2) to find out the points of weakness in terms of irreversibility of the process; and 3) to verify whether solar power plants can reduce environmental impact and the cost of electricity generation by comparing them with fossil fuel plants, in particular, Natural Gas Combined Cycle (NGCC) plant and oil thermal power plant. The analysis also targets a thermoeconomic analysis using the specific exergy costing (SPECO) method to evaluate the level of the cost caused by exergy destruction. The main technological findings are that the most important contribution impact lies with the solar field, which reports a value of 79%; and the materials with the vi highest impact are: steel (47%), molten salt (25%) and synthetic oil (21%). The “Human Health” damage category presents the highest impact (69%) followed by the “Resource” damage category (24%). In addition, the highest exergy demand is linked to the steel (47%); and there is a considerable exergetic demand related to the molten salt and synthetic oil with values of 25% and 19%, respectively. Finally, in the comparison with fossil fuel power plants (NGCC and Oil), the CSP plant presents the lowest environmental impact, while the worst environmental performance is reported to the oil power plant followed by NGCC plant. The solar field presents the largest value of cost rate, where the boiler is a component with the highest cost rate among the power cycle components. The thermal storage allows the CSP plants to overcome solar irradiation transients, to respond to electricity demand independent of weather conditions, and to extend electricity production beyond the availability of daylight. Numerical analysis of the thermal transient response of a thermocline storage tank is carried out for the charging phase. The system of equations describing the numerical model is solved by using time-implicit and space-backward finite differences and which encoded within the Matlab environment. The analysis presented the following findings: the predictions agree well with the experiments for the time evolution of the thermocline region, particularly for the regions away from the top-inlet. The deviations observed in the near-region of the inlet are most likely due to the high-level of turbulence in this region due to the localized level of mixing resulting; a simple analytical model to take into consideration this increased turbulence level was developed and it leads to some improvement of the predictions; this approach requires practically no additional computational effort and it relates the effective thermal diffusivity to the mean effective velocity of the fluid at each particular height of the system. Altogether the study indicates that the selected parabolic trough-CSP plant has the edge over alternative competing technologies for locations where DNI is high and where land usage is not an issue, such as the shoreline of Libya.
O projeto de Doutoramento aborda o potencial de usar centrais de energia solar concentrada (CSP) como um sistema de produção de energia alternativa disponível na Líbia. Uma análise nas vertentes exergética, energética, económica e ambiental foi realizada para um tipo particular destas centrais – um sistema de 50 MW com receção parabólica, porém ela é suficientemente geral para ser aplicada a outras configurações. A originalidade do estudo, para além da modelação e análise da configuração selecionada encontra-se na utilização do estado da arte em termos da análise exergética combinada com a avaliação do ciclo de vida (LCA). A modelação e simulação da central CSP selecionada são efetuadas no terceiro capítulo tendo em consideração as duas componentes: ciclo de potência e campo de coletores solar. O modelo computacional para a análise do sistema foi desenvolvido com base em equações algébricas que descrevem o sistema, e que são resolvidas usando o software EES. Deste modo, são definidas as propriedades em cada ponto de interesse para os diferentes elementos do sistema, o que assim permite determinar as energias, eficiências e irreversibilidades desses elementos. O modelo desenvolvido tem o potencial de se tornar uma ferramenta de grande utilidade para o projeto preliminar de engenharia de centrais CSP, e também para a avaliação da eventual reconfiguração de centrais elétricas solares comerciais em operação. Além disso, o modelo pode ser utilizado no estudo de viabilidade da operação de centrais CSP, através da análise energética, económica e ambiental, para regiões diferentes da que foi escolhida no presente estudo -Trípoli (Líbia). O cenário total da viabilidade da operação da central CSP é completado através da análise horária com base anual apresentada no quarto capítulo. Esta análise permite a comparação de diferentes sistemas e, eventualmente permite fazer a seleção com base nas componentes económicas e energéticas, que são determinadas dentro do contexto do software greenius. A análise também toma em conta o impacto de financiamento e incentivos dados aos projetos no custo da produção de energia. O principal resultado desta análise é a verificação que o desempenho é mais elevado, com o consequente menor custo nivelado da eletricidade, para a Líbia em comparação com o Sul da Europa (Espanha). Assim a Líbia tem o potencial de se tornar um candidato atrativo para o estabelecimento de centrais CSP com o objetivo, como foi considerado em várias iniciativas europeias, de exportar eletricidade gerada através de fontes de energia renováveis de países do Norte de África e Médio Oriente para a Europa. A análise apresenta uma breve revisão do custo corrente da eletricidade e o potencial para reduzir o custo da energia a partir da tecnologia de receção parabólica de centrais CSP. A avaliação do ciclo de vida com base exergética (ELCA) e a avaliação do ciclo de vida convencional são realizadas para a centrais CSP específicas no quinto capítulo. Os objetivos são 1) avaliar o impacto ambiental e custo, em termos de do ciclo iv de vida exergético do sistema; 2) identificar pontos fracos em termos da irreversibilidade dos processos; e 3) verificar se as centrais CSP podem reduzir o impacto ambiental e o custo de geração de eletricidade em comparação com centrais que consomem combustível fóssil. O capítulo ainda apresenta uma análise termoeconómica com base na metodologia do custo específico da exergia (SPECO), que avalia o custo relacionado com a destruição de exergia. A análise verificou que o impacto mais importante é a contribuição apresentada pelo campo solar (79%), e os materiais com maior impacto são: aço (47%), sal fundido (25%) e óleo sintético (21%). A análise ELCA mostra que a maior demanda de exergia é devida ao aço (47%); a análise existe uma considerável demanda de exergia relacionada com o sal fundido e ainda o óleo sintético. Em comparação com as centrais que consomem combustível fóssil (NGCC e óleo) a central sistema CSP apresenta menor impacto ambiental, enquanto o pior desempenho ambiental é o da central com queima de óleo seguida pela central a gás natural (NGCC). Na central CSP, o campo solar apresenta o custo mais elevado, enquanto o gerador de vapor, entre os componentes do ciclo de potência, apresenta o maior custo. O armazenamento de energia térmica permite que as centrais CSP superem a intermitência de radiação solar para responder à procura de energia elétrica independentemente das condições climáticas, e também possam estender a produção de eletricidade para além da disponibilidade da radiação solar diária. A análise numérica do transiente térmico de um sistema de armazenamento de gradiente térmico é realizada durante a fase de carregamento. O sistema de equações que descreve o modelo numérico é resolvido através da utilização de diferenças finitas implícitas no tempo usando o software Matlab. Os resultados da análise indicam que as previsões estão em boa concordância com os dados experimentais para a evolução no tempo da região de gradiente térmico, em particular para regiões mais afastadas da entrada. Nesta região os desvios observados são provavelmente causados pelo alto nível de turbulência devido à penetração do jato no seio do tanque de armazenamento. O modelo analítico simples para simular a turbulência que foi desenvolvido melhora os resultados. Esta abordagem não requer esforço computacional adicional e determina a difusidade térmica efetiva ao longo do tanque.
Beviss-Challinor, Lauren Margaret. "Design, build and test a passive thermal system for a loft : a roof solar chimney application for South African weather conditions." Thesis, Stellenbosch : Stellenbosch University, 2007. http://hdl.handle.net/10019.1/348.
Full textENGLISH: The design, construction and testing of a passive thermal system, a roof solar chimney, for a loft is considered. Unlike conventional solar chimneys the solar collector is constructed from corrugated iron roof sheets with the aim that it can be integrated into existing buildings at a lower cost or used in low cost housing developments. The main objective of the study was to determine the feasibility of such low-cost design to regulate thermal conditions in a loft, that is heating the loft during winter and enhancing natural ventilation during summer, by carrying out an experimental and analytical study. The results obtained from the experimental study showed that for winter the solar chimney, having a channel width, depth and length of 0.7 m, 0.1 m and 1.8 m respectively and with a peal solar radiation of 850 W/m², heated the room air 5°C higher than the ambient temperature during the hottest periods of the day, which is only marginally better than a loft with conventional roof insulation. At night, it was found that reverse airflow occurred through the chimney, cooling the loft down to ambient temperature, due to radiation heat loss from the roof collector to the night sky. For summer operation, the experimental data showed that the chimney was able to maintain the loft at ambient temperature and the analytical study found that the chimney was able to enhance natural ventilation effectively, reaching air exchange rate of 6.6 per hour for the 4.6 m³ volume space. It was also found that the chimney’s performance dropped rapidly and significantly during periods of low solar radiation and at night. A sensitivity analysis illustrated that for both summer and winter operation, the size, tilt angle and absorptivity of the roof collector greatly effected the efficiency and mass flow rates of the system, agreeing well with other literature. These results prove that this low cost solar chimney cooling design was feasible to enhance natural ventilation mainly during hot summer conditions with high solar radiation. Compared to a loft with only conventional roof insulation, the chimney did not perform effectively during the winter to heat the loft up, meaning that winter operation for this specific design is not feasible. Possible improvements to the design include using construction materials with higher thermal capacities to retain heat energy and ensure continued operation during periods of low solar radiation, as well as using selective absorber coatings on the collector surface. It is recommended that further work on the project include the integration of these improvements into the present design and to use the findings obtained from the sensitivity analysis to improve system efficiencies. CFD analysis of the test-rig will be insightful as an additional means to validate and compare with the analytical and experimental data obtained in this report. With the continuation of these studies, this low-cost solar chimney design can be optimised, validated on a commercial scale and built into existing and new housing developments. Incorporating such a passive thermal device will aid homeowners in air regulation and thermal comfort of their living space as well as saving on energy requirements.
Sponsored by the Centre for Renewable and Sustainable Energy Studies, Stellenbosch University
Rizzi, M. "HIGH TEMPERATURE OXIDATION PHENOMENA'S STUDY OF HIGH ALLOYED MATERIALS FOR POWER GENERATION PLANTS." Doctoral thesis, Università degli Studi di Milano, 2012. http://hdl.handle.net/2434/168364.
Full textLlovera, Bonmatí Albert. "Market role, profitability and competitive features of thermal power plants in the Swedish future electricity market with high renewable integration." Thesis, Uppsala universitet, Elektricitetslära, 2017. http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-330392.
Full textLundholm, Diana. "Thirsty coal: Assessing climate change impacts on water availability and vulnerability of thermal power plants in Poland up to 2050." Thesis, Uppsala universitet, Institutionen för geovetenskaper, 2021. http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-445133.
Full textDolek, Emre. "Comparison Of Iscst3 And Aermod Air Dispersion Models: Case Study Of Cayirhan Thermal Power Plant." Master's thesis, METU, 2007. http://etd.lib.metu.edu.tr/upload/12609207/index.pdf.
Full textayirhan Thermal Power Plant to determine the effects of the plant on the environment. Stack gas measurement results were used for the emissions from the power plant and emission factors were used for calculating the emissions from residential sources and coal stockpiles in the study region. Ground level concentrations of SO2, NOx and PM10 were estimated by using EPA approved dispersion models
namely ISCST3 and AERMOD. The ground level concentrations predicted by two models were compared with the results of ambient air pollution measurements for November 2004. Predictions of both ISCST3 and AERMOD were underestimating the ground level SO2 concentrations. However, AERMOD predictions are better than ISCST3 predictions. The results of both models had good correlation with the results of NOx measurements. It has been shown that the contribution of the power plant to SO2, NOx and PM10 pollution in the area studied is minimal.
Pragada, Gandhi, and Nitish Perisetla. "Utility-Scale Solar Power Plants with Storage : Cost Comparison and Growth Forecast Analysis." Thesis, KTH, Skolan för industriell teknik och management (ITM), 2021. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-301838.
Full textFörnybar energi för energiproduktion, liksom Solar, visar sig vara mycket relevant i dagens värld [1]. Det är mycket tydligt att solenergi kommer att framstå som en av de viktigaste energikällorna i framtiden. Dessutom kommer lagringsalternativet att spela en väsentlig roll för den framtida distributionen av solkraftverk. Koncentrerade solkraftverk med värmelagring, solcellsanläggningar integrerade med batterilagring och hybridanläggningar är attraktiva lösningar för att få en stabil och skickbar energiproduktion. Investerare eller beslutsfattare brukar tycka att det är utmanande att komma på den mest genomförbara solcellstekniken eftersom de måste överväga teknikekonomisk genomförbarhet, och samtidigt, ur ett marknads- eller administrativt perspektiv också. Så denna avhandlingsstudie kommer att ta itu med nyckelproblemet som riktar sig till investerare eller beslutsfattare eftersom det finns ett behov av att välja den bästa solenergilagringstekniken på en användningsnivå i framtiden baserat på så många attribut. Avhandlingsprojektet genomfördes i två faser som inkluderar prognosmodellering och uppskattningar och teknikekonomisk bedömning av virtuella anläggningar. Dessa två faser hjälpte till att ta itu med olika frågor i samband med problemstudien i denna studie. Hela avhandlingsstudien omfattade i stort sju länder som sträcker sig över fyra stora regioner runt om i världen. Den första fasen i avhandlingen, prognosmodelleringsuppskattningar visar hur de sju länderna kommer att se ut i framtiden (2020 - 2050) med avseende på installerad kapacitet och kostnader för PV-, CSP- och BESS -teknik. Några viktiga resultat från fas 1 inkluderar, i lågkostnadsuppskattningar, att Kina kommer att vara marknadsledande inom PV och CSP år 2050. I USA och Indien beräknas de installerade kostnaderna för PV minska med 70% år 2050. Av 2050 beräknas de installerade kostnaderna för Solar Tower -teknik sjunka med cirka 65% i Kina och Spanien. I USA kommer priserna på BESS -teknik sannolikt att sjunka med cirka 58 - 60 % år 2050. I den andra fasen av avhandlingsstudien behandlade en teknikekonomisk utvärdering av virtuella anläggningar de aspekter som ska övervägas för ett solprojekt om det används i framtiden i sju specifika länder. Resultaten från denna analys hjälper investerare eller beslutsfattare att välja den billigaste solenergilagringstekniken på en användningsnivå i sju specifika länder i framtiden (2020 - 2050). Viktiga resultat från denna analys visar att i USA, år 2050, kommer PV+BESS att vara den billigaste lagringstekniken på 4 - 10 lagringstimmar. Tillägg av en annan förnybar teknik kommer att öka jämförbarheten. I Kina kommer Hybrid att vara den billigaste lagringstekniken i 4-8 timmar fram till 2050. Det finns en enorm potential för distribution av CSP & hybridanläggningar i framtiden än PV. I Sydafrika kommer CSP att vara den billigaste lagringstekniken år 2050 för 4 - 10 timmars lagring. Det antas att distributionen av BESS -projekt på verktygsnivå börjar från 2025 i Sydafrika. Utöver detta genomfördes marknadskravsanalys som ger insikter speciellt för beslutsfattarna om hur olika drivkrafter och begränsningar påverkar varje solteknik i de specifika länderna i framtiden. Sammantaget ger hela avhandlingsstudien riktlinjer/insikter till investerare eller beslutsfattare för att välja den bästa solenergitekniken i framtiden i en nyttoskala för ett visst land.
RIBEIRO, JUNIOR JOAQUIM A. "Um estudo simplificado da percepção pública dos benefícios e riscos de centrais termonucleares - sugestões para a comunicação de valor com o público." reponame:Repositório Institucional do IPEN, 2007. http://repositorio.ipen.br:8080/xmlui/handle/123456789/11504.
Full textMade available in DSpace on 2014-10-09T14:02:25Z (GMT). No. of bitstreams: 0
Dissertação (Mestrado)
IPEN/D
Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
Nahhas, Tamar. "Materials and thermal storage systems by sensible heat for thermodynamic electro-solar plants." Thesis, Perpignan, 2017. http://www.theses.fr/2017PERP0027.
Full textCompare to fossil fuel energy resources, solar energy is known for its intermittent nature. This observation highlights the need for the use of a thermal energy storage system. The thermocline storage system is considered as a cost-effective storage system. This thesis aims to study the potential of basalt and silex rocks as candidate storage materials for concentrated solar power plants. Experimental studies of the thermo-physical and thermo-mechanical properties of these rocks at temperatures up to 1000°C show that these rocks offer good thermal properties compared with conventional storage materials. The analysis of the thermocline storage system of air rock-packed bed is carried out using a numerical approach. This research also aims to assess the environmental impact of this type of storage system by conducting a comparative analysis of its life cycle. Finally, a complementary study carried out with the aim of producing a relevance index map made it possible to identify the most suitable areas for the construction of solar power plants in Egypt. The originality of this alternative approach for thermal energy storage is that it combines the performance and availability of storage materials while reducing their environmental and financial impacts
Trahan, Jamie. "A Technical and Economic Comparative Analysis of Sensible and Latent Heat Packed Bed Storage Systems for Concentrating Solar Thermal Power Plants." Scholar Commons, 2015. https://scholarcommons.usf.edu/etd/5598.
Full textQiu, Bin. "Simulating Thermal and Chemical Spills in Coupled Cooling Reservoirs." Thesis, University of North Texas, 1997. https://digital.library.unt.edu/ark:/67531/metadc279271/.
Full textNuutinen, Antti, and Giovanni Graziano. "Towards Flexible Cogeneration: Techno-economic Optimization of Advanced Combined Cycle Combined Heat and Power Plants integrated with Heat Pumps and Thermal Energy Storage." Thesis, KTH, Energiteknik, 2018. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-235820.
Full textWong, Anthony Ling Chiung. "Sequestering of CO2 in the oceans around Australia." Thesis, The University of Sydney, 1994. https://hdl.handle.net/2123/26895.
Full text