To see the other types of publications on this topic, follow the link: OSSEOINTEGRAÇÃO (ODONTOLOGIA).

Dissertations / Theses on the topic 'OSSEOINTEGRAÇÃO (ODONTOLOGIA)'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 32 dissertations / theses for your research on the topic 'OSSEOINTEGRAÇÃO (ODONTOLOGIA).'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

Triches, Diego Fernandes. "Relação entre qualidade óssea clínica e radiográfica e a estabilidade primária de implantes curtos em região posterior." Pontifícia Universidade Católica do Rio Grande do Sul, 2013. http://hdl.handle.net/10923/5509.

Full text
Abstract:
Made available in DSpace on 2013-10-11T13:36:07Z (GMT). No. of bitstreams: 1 000450854-Texto+Completo-0.pdf: 2937082 bytes, checksum: a58744bec268788ef21970b772d8b358 (MD5) Previous issue date: 2013<br>Short implants have shown success rates similar to implants of conventional length, and both bone quality and initial stability of the receptor site of the implant may influence prognosis. Therefore, this study aimed to evaluate three methods of measuring implant stability - insertion torque (IT), Periotest (PTV) and Osstell (ISQ) - and the effect of bone quality evaluated during surgery (Leck
APA, Harvard, Vancouver, ISO, and other styles
2

Bondan, João Lopes. "Análise comparativa da precisão de adaptação entre componentes UCLA e implante de um mesmo sistema." Pontifícia Universidade Católica do Rio Grande do Sul, 2007. http://hdl.handle.net/10923/472.

Full text
Abstract:
Made available in DSpace on 2011-12-27T14:14:20Z (GMT). No. of bitstreams: 2 000390167-0.pdf: 8479233 bytes, checksum: 78f267d7711851d94f32594d0a86c23d (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5)<br>The aim of this study was to evaluate the fit between the components UCLA and implant of the same system (Neodent). The comparison was made through an evaluation of the vertical and horizontal gaps present at the interface between implant and UCLA, through scanning electronic microscopy (SEM), measurements in selected locations. Statistical analysis was done throu
APA, Harvard, Vancouver, ISO, and other styles
3

Passoni, Bernardo Born. "Influência do momento e posicionamento de instalação do implante na formação óssea peri-implantar em diferentes tratamentos de superfície." reponame:Repositório Institucional da UFSC, 2014. https://repositorio.ufsc.br/xmlui/handle/123456789/123282.

Full text
Abstract:
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2014.<br>Made available in DSpace on 2014-08-06T18:02:01Z (GMT). No. of bitstreams: 1 326581.pdf: 3035055 bytes, checksum: 095d3c7a9b9f63dfed812985a304d6da (MD5) Previous issue date: 2014<br>Objetivos: verificar a influência do momento de instalação e do posicionamento do implante, bem como a presença ou não do GAP vestibular, associado ao seu tratamento de superfície, na formação óssea ao redor dos implantes. Materiais e métodos: Em um primei
APA, Harvard, Vancouver, ISO, and other styles
4

Guimarães, Magáli Beck. "Influência da aplicação local de bisfosfonato na osseointegração de implantes de titânio instalados em tíbia de coelho." Pontifícia Universidade Católica do Rio Grande do Sul, 2014. http://hdl.handle.net/10923/6949.

Full text
Abstract:
Made available in DSpace on 2014-12-03T01:01:44Z (GMT). No. of bitstreams: 1 000463068-Texto+Completo-0.pdf: 2847170 bytes, checksum: 24881d931a22a088ffe1f361a64aed3c (MD5) Previous issue date: 2014<br>The aim of this study was to make a comparative analysis of aspects related to the osseointegration of titanium implants placed with and without local application of a bisphosphonate, after 4 weeks, in vivo. The study comprised the placement of 50 cp. titanium implants in the middle third of the tibia of 10 rabbits, with the right tibia being used as control, and the left as test site. In the
APA, Harvard, Vancouver, ISO, and other styles
5

Alonso, Fernando Rizzo. "Análise das estabilidades primária e secundária de implantes curtos unitários instalados na região posterior." Pontifícia Universidade Católica do Rio Grande do Sul, 2013. http://hdl.handle.net/10923/5511.

Full text
Abstract:
Made available in DSpace on 2013-10-11T13:36:08Z (GMT). No. of bitstreams: 1 000450848-Texto+Completo-0.pdf: 1608827 bytes, checksum: 3e7ff522aa354768faac74eab4ba6daa (MD5) Previous issue date: 2013<br>Clinical evidences suggest that the stability of dental implants plays an important role on the success of osseointegration. However, there is not sufficient information with respect to the stability of short (6-mm long) implants. Thus, the aims of this study were: 1) to assess clinically and longitudinally the stability of short implants in relation to the bone quality, by means of insertion
APA, Harvard, Vancouver, ISO, and other styles
6

Gil, Luiz Fernando. "Avaliação ao longo do tempo da osseointegração em 93 implantes em forma de platôs removidos de humanos." reponame:Repositório Institucional da UFSC, 2014. https://repositorio.ufsc.br/xmlui/handle/123456789/123324.

Full text
Abstract:
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2014.<br>Made available in DSpace on 2014-08-06T18:04:50Z (GMT). No. of bitstreams: 1 327158.pdf: 831762 bytes, checksum: 7954cc7d9bd4484428bd1e4c54427f71 (MD5) Previous issue date: 2014<br>O objetivo deste estudo foi avaliar a osseointegração de implantes em forma de platôs removidos de humanos considerando o tempo de carga funcional e a variáveis relativas ao sistema de implante utilizado e a fatores ligados ao paciente. Foi realizada anális
APA, Harvard, Vancouver, ISO, and other styles
7

Guimarães, Magáli Beck. "Avaliação da influência de diferentes superfícies na adesão e proliferação de osteoblastos humanos." Pontifícia Universidade Católica do Rio Grande do Sul, 2010. http://hdl.handle.net/10923/379.

Full text
Abstract:
Made available in DSpace on 2011-12-27T14:14:05Z (GMT). No. of bitstreams: 2 000422228-0.pdf: 2027786 bytes, checksum: fc45ed715786efb01f83f7fff755ceef (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5)<br>Nowadays, the focus of many researches in Implant Dentistry is on the modification of the titanium surface in search of alternatives that can provide more quickness and quality to the osseointegration process. Osseointegration is a phenomenon that happens mainly through the interfacial response of bone cells in contact with the titanium surface. There are differen
APA, Harvard, Vancouver, ISO, and other styles
8

Souza, João Gustavo Oliveira de. "Influência dos fatores locais e sistêmicos na osseointegração e perda óssea ao redor de implantes." reponame:Repositório Institucional da UFSC, 2012. http://repositorio.ufsc.br/xmlui/handle/123456789/93542.

Full text
Abstract:
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-graduação em Odontologia, Florianópolis, 2010<br>Made available in DSpace on 2012-10-24T23:56:50Z (GMT). No. of bitstreams: 1 284180.pdf: 2168687 bytes, checksum: 3ee357ae46210ab12fa4eb4763918621 (MD5)<br>A proposta deste estudo foi avaliar, retrospectivamente, o sucesso dos implantes e a influência de fatores locais e sistêmicos na osseointegração e perda óssea ao redor de implantes orais em pacientes que apresentam implantes em função por 1 a 8 anos. Foram selecionados 193 pacientes
APA, Harvard, Vancouver, ISO, and other styles
9

Post, Letícia Kirst. "Análise comparativa do efeito de diferentes superfícies sobre a resposta tecidual perimplantar em regiões com baixa densidade óssea: modelo animal coelho." Pontifícia Universidade Católica do Rio Grande do Sul, 2009. http://hdl.handle.net/10923/387.

Full text
Abstract:
Made available in DSpace on 2011-12-27T14:14:07Z (GMT). No. of bitstreams: 2 000417615-0.pdf: 921449 bytes, checksum: b1758518b6fea65cac8a47bf9564b908 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5)<br>The possibilities of changing implant surface properties are numerous, both in terms of chemical and biological aspects and also of surface morphology and topography. Recent studies have focused on establishing an implant surface with characteristics that optimize osseointegration in sites with low bone density. The aim of the present study was to carry out clinica
APA, Harvard, Vancouver, ISO, and other styles
10

Azambuja, Fabiano Goulart. "Estudo estrutural e ultraestrutural da interface osso-implante em ovelhas." Pontifícia Universidade Católica do Rio Grande do Sul, 2009. http://hdl.handle.net/10923/539.

Full text
Abstract:
Made available in DSpace on 2011-12-27T14:14:33Z (GMT). No. of bitstreams: 2 000422969-0.pdf: 4980923 bytes, checksum: 2690ee5096ce9b097a8aa97b37d89ecf (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5)<br>Studies have showed that roughness surfaces in titanium implants can modulate bones responses. The objective of present study is evaluate the bone implant contact between two types of dentistry implants with differents treatments of surface, Titamax EX Cone Morse® sandblasted/acid-etched and a Titamax EX Cone Morse® with a new proposal surface called nanosurface,
APA, Harvard, Vancouver, ISO, and other styles
11

Beltrão, Rodrigo Gomes. "Análise da diferenciação de células da medula óssea humana cultivadas sobre diferentes superfícies de titânio." Pontifícia Universidade Católica do Rio Grande do Sul, 2009. http://hdl.handle.net/10923/559.

Full text
Abstract:
Made available in DSpace on 2011-12-27T14:14:37Z (GMT). No. of bitstreams: 2 000417773-0.pdf: 1138982 bytes, checksum: 03423e2cddaa5a43349be69c0853e615 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5)<br>Given that the majority of osseointegrated implants undergo some type of surface conditioning in order to improve osseoitegration and that in vitro differentiation of mesenchymal cells into osteoblasts is a mastered process that has been used for evaluating a given biomaterial with regard to its osteinductive and osteoconductive capabilities, the present work aims
APA, Harvard, Vancouver, ISO, and other styles
12

Nunes, Leandro Soeiro de Souza. "Avaliação histológica do contato osso-implante e estabilidade de implantes com superfícies modificadas: estudo experimental em tíbias de coelhos." Pontifícia Universidade Católica do Rio Grande do Sul, 2014. http://hdl.handle.net/10923/7288.

Full text
Abstract:
Made available in DSpace on 2015-05-22T12:38:48Z (GMT). No. of bitstreams: 1 000468625-Texto+Completo-0.pdf: 2863238 bytes, checksum: 3e057c78a6b6e5cfbd0cf6767d59dd26 (MD5) Previous issue date: 2014<br>The clinical success of the implant treatment is strongly related with the achievement and maintenance of the stability of the fixture. As the surface topography, roughness and wettability are modifications that can affect the quality of the osseointegration, several studies have analyzed the benefits of these modifications. The histomorphometric analyses of the bone-to-implant contact (BIC) a
APA, Harvard, Vancouver, ISO, and other styles
13

Abreu, Marcelo Emir Requia. "Hormônio do crescimento no processo de osseointegração de implantes de titânio: estudo experimental e revisão de literatura." Pontifícia Universidade Católica do Rio Grande do Sul, 2011. http://hdl.handle.net/10923/497.

Full text
Abstract:
Made available in DSpace on 2011-12-27T14:14:24Z (GMT). No. of bitstreams: 2 000435511-0.pdf: 4163986 bytes, checksum: 37629882e85d83ed66d26ed9bed14b82 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5)<br>In order to accelerate and improve the quality of the osseointegration process has recently been given emphasis to growth factors. Thus, this thesis was aimed to evaluate the use of growth hormone (GH) on osseointegration of titanium implants. This thesis is composed of two papers, the first chapter is a review of literature on the use of growth factors, and, in p
APA, Harvard, Vancouver, ISO, and other styles
14

Geremia, Tomás. "Efeito da inclinação e do número de implantes em próteses totais fixas implantossuportadas: análise de elemento finito não linear com modelo tridimensional." Pontifícia Universidade Católica do Rio Grande do Sul, 2014. http://hdl.handle.net/10923/7182.

Full text
Abstract:
Made available in DSpace on 2015-04-30T14:06:27Z (GMT). No. of bitstreams: 1 000467680-Texto+Completo-0.pdf: 13016515 bytes, checksum: e3ef505603c7d5be9a1581e535fd60e2 (MD5) Previous issue date: 2014<br>The aim of this study was to evaluate the influence of the number of implants and the distal tilting of posterior implants (27 degrees) on the resulting tensions in periimplant bone, abutment screw and prosthetic screw of mandibular full-arch fixed implant supported prosthesis, using a nonlinear finite element analysis. Six virtual models were created, simulating a mandibular full-arch prosth
APA, Harvard, Vancouver, ISO, and other styles
15

Zanferrari, Fernando Luiz. "Comportamento de implantes de cimento portland em fase sólida : análise dimensional e histomorfométrica / Fernando Luiz Zanferrari ; orientador, Wilson Denis Martins." reponame:Biblioteca Digital de Teses e Dissertações da PUC_PR, 2011. http://www.biblioteca.pucpr.br/tede/tde_busca/arquivo.php?codArquivo=2157.

Full text
Abstract:
Tese (doutorado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2010<br>Bibliografia: f. 69-73<br>Objetivos: O objetivo deste trabalho foram avaliar a estabilidade dimensional do cimento Portland branco quanto ao seu volume e área superficial, mensurar a quantidade de tecido ósseo neoformado por meio de histomorfometria após implantação subperióstea d<br>Objectives: The aim of this study was to evaluate the dimensional stability of white Portland cement as its volume and surface area, measure the amount of new bone by histomorphometry after subperiosteal implantation of samples of Por
APA, Harvard, Vancouver, ISO, and other styles
16

Meyer, Kleber Ricardo Monteiro. "Avaliação da ação do laser (AsGaAl) no torque de remoção de implantes lisos e texturizados." Pontifícia Universidade Católica do Rio Grande do Sul, 2008. http://hdl.handle.net/10923/403.

Full text
Abstract:
Made available in DSpace on 2011-12-27T14:14:09Z (GMT). No. of bitstreams: 2 000408029-0.pdf: 5297005 bytes, checksum: b759a1194fe1debd841abcedaff116d7 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5)<br>This work evaluated the laser (AsGaAl) laser effect by torque removal method, in different healing periods, of smooth and texturized standard model implants, installed in male New Zealand rabbit tibiae, submitted or not to low intensity laser irradiation. For the study, 16 animals, weighing between 3. 5 to 4. 0 kg, with two implants in each tibia, divided in four
APA, Harvard, Vancouver, ISO, and other styles
17

Sverzut, Alexander Tadeu 1975. "Estudo da perda precoce de implantes osseointegraveis realizados na Faculdade de Odontologia de Piracicaba - Unicamp no periodo de julho de 1996 a julho de 2004." [s.n.], 2006. http://repositorio.unicamp.br/jspui/handle/REPOSIP/288777.

Full text
Abstract:
Orientador: Roger William Fernandes Moreira<br>Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba<br>Made available in DSpace on 2018-08-06T03:09:52Z (GMT). No. of bitstreams: 1 Sverzut_AlexanderTadeu_M.pdf: 2148820 bytes, checksum: 85cecee7cb4767985821dc5ca0bd831f (MD5) Previous issue date: 2006<br>Resumo: As perdas de implantes dentários podem ser classificadas em precoces ou tardias segundo BUSER et al. (1991). Esse trabalho objetivou analisar a perda precoce de implantes dentários e os fatores de risco associados. Foram utilizados para anál
APA, Harvard, Vancouver, ISO, and other styles
18

Cunha, Alexandre. "Avaliação do crescimento ósseo em implantes de titânio revestidos por plasma spraying com diferentes interfaces metal-filme." Pontifícia Universidade Católica do Rio Grande do Sul, 2008. http://hdl.handle.net/10923/3237.

Full text
Abstract:
Made available in DSpace on 2013-08-07T18:53:51Z (GMT). No. of bitstreams: 1 000400633-Texto+Parcial-0.pdf: 244771 bytes, checksum: 929e01919e85f7195f849c8c0c09bddc (MD5) Previous issue date: 2008<br>Titanium and its alloys are widely applied as orthopedic and dental materials implants because of their excellent biocompatibility, low elastic modulus and high corrosion and wear resistance. The main causes that influence the adequate biomaterial functionality are the bone tissue growth and its adhesion to the implant surface. Recent researches indicated that the adhesion between the living bon
APA, Harvard, Vancouver, ISO, and other styles
19

Encarnação, Isis Carvalho. "Análise das propriedades físico-químicas e mecânicas de arcabouço poroso composto de PLGA, cerâmica bifásica e sinvastatina de liberação lenta para engenharia de tecido ósseo." reponame:Repositório Institucional da UFSC, 2016. https://repositorio.ufsc.br/xmlui/handle/123456789/167741.

Full text
Abstract:
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2016.<br>Made available in DSpace on 2016-09-20T04:15:50Z (GMT). No. of bitstreams: 1 340518.pdf: 22676667 bytes, checksum: 2b7347137b3b7d4a46fe8010f688abc8 (MD5) Previous issue date: 2016<br>Este estudo avaliou, in vitro, a liberação de sinvastatina em um arcabouço poroso inteligente , elaborado para engenharia de tecido ósseo, composto de PLGA e cerâmica bifásica, além das propriedades físico-químicas e mecânicas deste arcabouço. Foram obtidas am
APA, Harvard, Vancouver, ISO, and other styles
20

Torres, Marco Antônio Rambo Osório. "Influência do laser de baixa potência (GaAIAs - λ830nm) na formação óssea em implantes lisos e texturizados: uma análise histomorfométrica". Pontifícia Universidade Católica do Rio Grande do Sul, 2007. http://hdl.handle.net/10923/530.

Full text
Abstract:
Made available in DSpace on 2011-12-27T14:14:31Z (GMT). No. of bitstreams: 2 000399356-0.pdf: 4105847 bytes, checksum: 0c59a09fa1073f779a885d9635fec74e (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5)<br>This research in vivo blind-controlled was to investigate post mortem, through the histomorphometrical analysis, the influence of the low power laser in bone formation on machined and roughened titanium dental implants inserted in rabbits tibia-bones. The animals were subjected or not to the GaAlAs irradiation laser device, with a length of wave of 830nm, in a con
APA, Harvard, Vancouver, ISO, and other styles
21

Souza, Edmo Matheus Rocha de. "Influência da zircônia no arrefecimento de brocas para implantes osseointegráveis: ensaio mecânico." Universidade Federal de Sergipe, 2015. https://ri.ufs.br/handle/riufs/5895.

Full text
Abstract:
Specimens were made from bovine ribs and milling divided into two groups (A - B mills in steel - mills in zirconia), each group was divided into four subgroups according to different settings milling (rotation and pressure milling). They were measured and compared the temperatures of the milling burs made by the two materials made using four different configurations. A prosthetic surveyor has been adapted to the study to connect a surgical electronic engine, counter angle driver for implants. A container was also coupled to one of the liner's arms to accommodate components metallic spheres of
APA, Harvard, Vancouver, ISO, and other styles
22

Oliveira, Maiolino Thomaz Fonseca. "Avaliação in vitro e in vivo do efeito da cobertura de biossilicato aplicado sobre a superfície de titânio durante a osseointegração." Universidade Federal de Uberlândia, 2013. https://repositorio.ufu.br/handle/123456789/16968.

Full text
Abstract:
The aim of this study was to evaluate in vivo, using beagle dog model, the effect of incorporation of biossilicato (highly bioactive glass) on the process of osteogenesis through the bone-implant contact and evaluate in vitro using model cell culture, the influence of the incorporation of biossilicato the rough surface on titanium discs adhesion and cell viability. The implants used for the in vivo study (n = 32) were 10 mm long and 3.5 mm in diameter and having surface treated with double etching. Half of these implants (n = 16) received the incorporation of biossilicato on its surface roughe
APA, Harvard, Vancouver, ISO, and other styles
23

Bielemann, Amália Machado. "Comparação entre os marcadores inflamatórios no fluido crevicular periimplantar e os parâmetros clínicos de saúde durante a osseointegração em desdentados totais." Universidade Federal de Pelotas, 2016. http://repositorio.ufpel.edu.br:8080/handle/prefix/3546.

Full text
Abstract:
Submitted by Márcio Ropke (ropke13marcio@gmail.com) on 2017-06-19T13:24:54Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Comparação entre os marcadores inflamatórios no fluido crevicular periimplantar.pdf: 1235020 bytes, checksum: 767b18e33dcb6901781fc3f790872fc4 (MD5)<br>Made available in DSpace on 2017-06-19T13:24:54Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Comparação entre os marcadores inflamatórios no fluido crevicular periimplantar.pdf: 1235020 bytes, checksum: 767b18e33dcb6901781fc3
APA, Harvard, Vancouver, ISO, and other styles
24

Bermúdez, Jorge Pailover. "Aderência de Escherichia coli em discos de titânio submetidos a diferentes tratamentos de superfície antes e após escovação simulada." Universidade Estadual de Ponta Grossa, 2016. http://tede2.uepg.br/jspui/handle/prefix/2621.

Full text
Abstract:
Submitted by Eunice Novais (enovais@uepg.br) on 2018-09-06T21:25:22Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Jorge Bermudez.pdf: 16940162 bytes, checksum: f38c4129fa53cc28958626daecff3dc7 (MD5)<br>Made available in DSpace on 2018-09-06T21:25:22Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Jorge Bermudez.pdf: 16940162 bytes, checksum: f38c4129fa53cc28958626daecff3dc7 (MD5) Previous issue date: 2016-02-16<br>Este estudo in vitro, avaliou a aderência microbiana em discos de titânio sub
APA, Harvard, Vancouver, ISO, and other styles
25

Veleda, Paula Prá. "Produção e caracterização de implantes nanotexturizados de titânio associado a liberação gradual de fármacos." Pontifícia Universidade Católica do Rio Grande do Sul, 2012. http://hdl.handle.net/10923/3252.

Full text
Abstract:
Made available in DSpace on 2013-08-07T18:54:00Z (GMT). No. of bitstreams: 1 000443419-Texto+Completo-0.pdf: 4259691 bytes, checksum: 3fbe554be4dac8a49f70f55d940079dd (MD5) Previous issue date: 2012<br>The aim of this study was to assess, in vivo, the effect of two different surface treatments of titanium implants - plasma-spray (PSA) and nano-textured plasma-spray (PSA-nano) - at the bone-to-implant interface (osseointegration), associated or not to the recombinant human growth hormone (rhGH). Twenty-four prototypes of pure titanium implants, 6-mm long and 2-mm wide, were especially fabrica
APA, Harvard, Vancouver, ISO, and other styles
26

CARNEIRO, Luciano Sandoval. "Comparação entre implantes unitários de superfície tratada e não tratada por sub-tração radiográfica digital em protocolos de carga imediata e convencional." Universidade Federal de Goiás, 2009. http://repositorio.bc.ufg.br/tede/handle/tde/1381.

Full text
Abstract:
Made available in DSpace on 2014-07-29T15:21:59Z (GMT). No. of bitstreams: 1 Dissertacao - Luciano Sandoval Carneiro.pdf: 579690 bytes, checksum: 7c2af9622df94b48e0c190f4b97fbcff (MD5) Previous issue date: 2009-03-27<br>Objectives: To compare by digital subtraction radiography (SR), matched to clinical evaluation, bone response to single-tooth treated (TS) and non-treated (NTS) surface implants on immediate (IM) and conventional (CO) loading protocols. Material and methods: 12 patients (8 underwent IM protocol and 4 underwent CO protocol) received 24 implants. Each subject received 2 implant
APA, Harvard, Vancouver, ISO, and other styles
27

Marin, Charles. "Avaliação histomorfométrica e teste de remoção ao torque do implante dentário com superfície Ossean®: estudo experimental em cães." Universidade Federal de Uberlândia, 2008. https://repositorio.ufu.br/handle/123456789/16846.

Full text
Abstract:
The objective of this study was to compare the biomechanical fixation and bone-to-implant contact (%BIC) between the OsseanTM, a bioceramic gritblasted and acid-etched surface versus a dual acid-etched implant surface (Control) in a beagle dog model. Control and OsseanTM implants (n=3) were subjected to a series of physico/chemical characterization tools including scanning electron microscopy (SEM), atomic force microscopy (AFM), and auger photoelectron spectroscopy (APS). The animal model comprised the placement of 72 implants along the proximal tibiae of 6 beagle dogs (36 per surface, 6 per
APA, Harvard, Vancouver, ISO, and other styles
28

Faeda, Rafael Silveira [UNESP]. "Avaliação de implantes de titânio com modificação da superfície por abrasão a laser ou recobrimento por hidroxiapatita biomimétrica. Estudo biomecânico em tíbia de coelhos." Universidade Estadual Paulista (UNESP), 2006. http://hdl.handle.net/11449/96204.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:28:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-03-16Bitstream added on 2014-06-13T20:08:38Z : No. of bitstreams: 1 faeda_rs_me_arafo.pdf: 1508242 bytes, checksum: 76a3276ed9cd6a6e7947d633681c4217 (MD5)<br>Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)<br>Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)<br>Universidade Estadual Paulista (UNESP)<br>O sucesso dos sistemas modernos de implantes dentais tem sido relacionado ao desenvolvimento do design e das características de superfícies dos implantes. O
APA, Harvard, Vancouver, ISO, and other styles
29

Nunes, Luiz Marcelo Amaral Galvão. "Avaliação do enxerto ósseo autógeno e estudo da osseointegração de implantes nos períodos de incorporação e maturação óssea em áreas submetidas a cirurgia de enxerto ósseo em elevação de seio maxilar." Universidade Federal de Juiz de Fora (UFJF), 2016. https://repositorio.ufjf.br/jspui/handle/ufjf/3149.

Full text
Abstract:
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-01-06T14:00:14Z No. of bitstreams: 1 luizmarceloamaralgalvaonunes.pdf: 1165890 bytes, checksum: 617cb8b85316ada8b08107c635bf0730 (MD5)<br>Approved for entry into archive by Diamantino Mayra (mayra.diamantino@ufjf.edu.br) on 2017-01-31T11:27:08Z (GMT) No. of bitstreams: 1 luizmarceloamaralgalvaonunes.pdf: 1165890 bytes, checksum: 617cb8b85316ada8b08107c635bf0730 (MD5)<br>Made available in DSpace on 2017-01-31T11:27:08Z (GMT). No. of bitstreams: 1 luizmarceloamaralgalvaonunes.pdf: 1165890 bytes, checksum: 617cb8b85316ada8b08107c635bf0
APA, Harvard, Vancouver, ISO, and other styles
30

Faeda, Rafael Silveira. "Avaliação de implantes de titânio com modificação da superfície por abrasão a laser ou recobrimento por hidroxiapatita biomimétrica. Estudo biomecânico em tíbia de coelhos /." Araraquara: [s.n.], 2006. http://hdl.handle.net/11449/96204.

Full text
Abstract:
Resumo: O sucesso dos sistemas modernos de implantes dentais tem sido relacionado ao desenvolvimento do design e das características de superfícies dos implantes. O propósito do presente estudo foi avaliar duas novas superfícies de implantes (modificada por laser - SML e recoberta por hidroxiapatita biomimética - HA), comparando-as a outros dois implantes comerciais, (superfície usinada - SU e modificada por jateamento e ataque ácido - SMC). Um total de 96 implantes (3,75 x 10mm), 24 de cada superfície, foram instalados na tíbia de coelhos e avaliados após 4, 8 e 12 semanas. Após os períodos d
APA, Harvard, Vancouver, ISO, and other styles
31

Oliveira, João Augusto Guedes de [UNESP]. "Efeito do tratamento de superfície na osseointegração de implantes dentários da liga TI-7,5Mo." Universidade Estadual Paulista (UNESP), 2012. http://hdl.handle.net/11449/103721.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:32:50Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-01-27Bitstream added on 2014-06-13T19:03:28Z : No. of bitstreams: 1 oliveira_jag_dr_guara.pdf: 2054384 bytes, checksum: 2056494b4d46299584c8acf22e9f6838 (MD5)<br>Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)<br>Os Biomateriais Metálicos são utilizados para reforçar ou para restaurar a forma e função de tecidos duros. Os implantes e próteses são utilizados para substituir ombros, joelhos, quadris e dentes perdidos entre outros. Nos últimos anos, varias ligas de titânio
APA, Harvard, Vancouver, ISO, and other styles
32

MagalhÃes, GlÃvia Maria Silveira. "âEfeitos do ranelato de estrÃncio sobre o tempo de osseointegraÃÃo de implantes dentÃrios de titÃnio instalados em tÃbia e em fÃmur de coelhosâ." Universidade Federal do CearÃ, 2009. http://www.teses.ufc.br/tde_busca/arquivo.php?codArquivo=3859.

Full text
Abstract:
Dentoflex<br>LaboratÃrio Servier do Brasil<br>A integraÃÃo dos implantes dentÃrios no osso tem sido amplamente relatada nas Ãltimas dÃcadas desde os trabalhos originais de Branemark e co-autores. O uso de implantes dentÃrios de titÃnio no tratamento de pacientes edÃntulos ou parcialmente edÃntulos tem se tornado uma alternativa para restauraÃÃo funcional e estÃtica, entretanto esses resultados dependem da quantidade e da qualidade do osso maxilar ou mandibular. Osteoporose à uma doenÃa que influencia a qualidade do tecido Ãsseo, tornando-o susceptÃvel à fratura. RelaÃÃo importante tem sido des
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!