Academic literature on the topic 'Photo Diode Array detector'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Photo Diode Array detector.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Photo Diode Array detector"

1

Liang, Yan Ru, Yu Yun Wen, Xiao Yan Hong, Zhen Bin Gong, and Wen Quan Li. "Laboratory Simulation Study of Photo-Degradation Process of Fenvalerate in Aqueous Solution." Applied Mechanics and Materials 312 (February 2013): 886–92. http://dx.doi.org/10.4028/www.scientific.net/amm.312.886.

Full text
Abstract:
A laboratory-made the efficient photochemical degradation experimental device, combined with high performance liquid chromatography-tandem diode array detector device (DAD), fluorescence detector (FLD), mass spectrometer detector (MS), research fenvalerate its photo degradation. The structure of the spectral characteristics is the product, photo degradation reaction kinetics of degradation products, suggesting fenvalerate light chemical degradation process in an aqueous solution. The spectral characteristics of fenvalerate under ultraviolet light can be degraded into smaller organic molecules;
APA, Harvard, Vancouver, ISO, and other styles
2

Gummadi, Sowjanya, and Rajya Lakshmi Nimmagadda. "Quantification of Pitolisant: A RP - HPLC study." YMER Digital 21, no. 06 (2022): 896–907. http://dx.doi.org/10.37896/ymer21.06/89.

Full text
Abstract:
Objective An attempt was made to develop a simple, isocratic and robust reverse phase high performance liquid chromatographic method for Pitolisant. Material and methods An Inertsil octa decyl silane column and photo diode array detector were employed for the quantification of Pitolisant at 268 nm using a mobile phase consisting of acetonitrile and 0.1 % v/v formic acid (90:10 % v/v) at a flow rate of 1.0 mL/min. for the efficient elution of Pitolisant. Results The developed method was validated for various parameters and the linearity range was observed at 25-150 µg/mL. The correlation coeffi
APA, Harvard, Vancouver, ISO, and other styles
3

Maynard, Michael S., and Heather D. Maynard. "HPLC assay for avermectin B1a and its two photoisomers using a photo diode array detector." Bulletin of Environmental Contamination and Toxicology 43, no. 4 (1989): 499–504. http://dx.doi.org/10.1007/bf01701926.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Akhade, M. S., and K. S. Laddha. "QUANTITATIVE ASSESSMENT OF VASICINE AND VASICINONE IN DIFFERENT MARKETED FORMULATIONS USING HPLC." INDIAN DRUGS 56, no. 08 (2019): 79–80. http://dx.doi.org/10.53879/id.56.08.11254.

Full text
Abstract:
The main aim was to study the variation in vasicine and vasicinone concentration in different marketed cough syrups using HPLC with photo-diode array detector. Since the marketed formulations were containing Adhathoda vasica extract of varying amount, the amount of vasicine, which is the main constituent, deviated extensively. Also a complete and effective extraction method for quantitative estimation of vasicine and vasicinone from these formulations has been developed. Subsequently, based on the results, it was concluded that the need arises to standardize these marketed formulations.
APA, Harvard, Vancouver, ISO, and other styles
5

Zunino, Alessandro, Giacomo Garrè, Eleonora Perego, Sabrina Zappone, Mattia Donato, and Giuseppe Vicidomini. "s2ISM: A Comprehensive Approach for Uncompromised Super-Resolution and Optical Sectioning in Image Scanning Microscopy." EPJ Web of Conferences 309 (2024): 04021. http://dx.doi.org/10.1051/epjconf/202430904021.

Full text
Abstract:
Image Scanning Microscopy (ISM) enables good signal-to-noise ratio (SNR), super-resolution and high information content imaging by leveraging array detection in a laser-scanning architecture. However, the SNR is still limited by the size of the detector, which is conventionally small to avoid collecting out-of-focus light. Nonetheless, the ISM dataset inherently contains the axial information of the fluorescence emitters. We leverage this knowledge to achieve computational optical sectioning without sacrificing the conventional benefits of ISM. We invert the physical model to fuse the raw data
APA, Harvard, Vancouver, ISO, and other styles
6

Maccarone, Aurora, Giulia Acconcia, Ulrich Steinlehner, et al. "Custom-Technology Single-Photon Avalanche Diode Linear Detector Array for Underwater Depth Imaging." Sensors 21, no. 14 (2021): 4850. http://dx.doi.org/10.3390/s21144850.

Full text
Abstract:
We present an optical depth imaging system suitable for highly scattering underwater environments. The system used the time-correlated single-photon counting (TCSPC) technique and the time-of-flight approach to obtain depth profiles. The single-photon detection was provided by a linear array of single-photon avalanche diode (SPAD) detectors fabricated in a customized silicon fabrication technology for optimized efficiency, dark count rate, and jitter performance. The bi-static transceiver comprised a pulsed laser diode source with central wavelength 670 nm, a linear array of 16 × 1 Si-SPAD det
APA, Harvard, Vancouver, ISO, and other styles
7

Garré, Giacomo, Alessandro Zunino, Francesco Fersini, and Giuseppe Vicidomini. "Pushing the performance of image scanning microscopy to its limits with maximum likelihood reconstruction." EPJ Web of Conferences 287 (2023): 03001. http://dx.doi.org/10.1051/epjconf/202328703001.

Full text
Abstract:
Fast and sensitive detector arrays make Image Scanning Microscopy (ISM) the natural successor of confocal microscopy. Indeed, ISM enables super-resolution at an excellent signal-to-noise ratio. Optimizing photon collection requires large detectors and so more out-of-focus light is collected. Nonetheless, the ISM dataset inherently contains information on the axial position of the fluorescence emitters. We exploit such information to directly invert the cmresponding physical model with a maximum-likelihood approach and reassign the signal in the thr ee dimensions, improving the signal-to-backgr
APA, Harvard, Vancouver, ISO, and other styles
8

Sondhia, Shobha. "Liquid Chromatographic Determination of Imazosulfuron in Food Commodity, Water and Soil Using Photo Diode Array Detector." Asian Journal of Chemistry 28, no. 5 (2016): 1021–23. http://dx.doi.org/10.14233/ajchem.2016.19570.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Ma, Kang, Ya Nan Yang, Xiao Xiong Jiang, Min Zhao, and Ye Qiang Cai. "Simultaneous determination of 20 food additives by high performance liquid chromatography with photo-diode array detector." Chinese Chemical Letters 23, no. 4 (2012): 492–95. http://dx.doi.org/10.1016/j.cclet.2011.12.018.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Brink, H. A., C. Trevor, J. Hunt, and P. E. Mooney. "A New High Performance Detector for Electron Energy Loss Spectroscopy." Microscopy and Microanalysis 6, S2 (2000): 212–13. http://dx.doi.org/10.1017/s1431927600033559.

Full text
Abstract:
The serial detectors traditionally used in Electron Energy Loss Spectroscopy (EELS) have mostly been replaced by parallel detection systems, for reasons of efficiency and ease of use. So far most parallel detection systems have been based on fiber or lens coupled Photo Diode Array (PDA). Although these systems have proven satisfactory they have some limitations: 1) high readout noise, 2) limited correction for gain variations and 3) point spread function or cross talk between channels all of which effects the ultimate sensitivity and resolution. This paper discusses a newly developed parallel
APA, Harvard, Vancouver, ISO, and other styles
More sources

Dissertations / Theses on the topic "Photo Diode Array detector"

1

MacQueen, Phillip J. "Solid-state image detector development : a linear diode array for astronomical spectroscopy." Thesis, University of Canterbury. Astronomy, 1986. http://hdl.handle.net/10092/8071.

Full text
Abstract:
Future spectroscopic observational programmes at Mount John University Observatory require the ability to acquire spectra with significantly higher spectrophotometric accuracy and geometrical stability than can currently be achieved. Therefore a solid-state linear-diode-array image detector system has been designed and developed for use with the MJUO échelle spectrograph. A review of those electromechanical design techniques of significance to astronomical instrumentation is presented. Their application is exemplified with a complete electromechanical design for the detector, which is found t
APA, Harvard, Vancouver, ISO, and other styles
2

Akcoren, Dincay. "A Low-cost Uncooled Infrared Detector Array And Its Camera Electronics." Master's thesis, METU, 2011. http://etd.lib.metu.edu.tr/upload/12613082/index.pdf.

Full text
Abstract:
This thesis presents the development of integrated readout electronics for diode type microbolometers and development of external camera electronics for microbolometers. The developed readout electronics are fabricated with its integrated 160x120 resolution FPA (Focal Plane Array) in the XFAB SOI-CMOS 1.0 &mu<br>m process. The pixels in the FPA have 70 &mu<br>m pixel pitch, and they are sensitive in the 8&ndash<br>12 &mu<br>m band of the infrared spectrum. Each pixel has 4 serially connected diodes, and diode turn on voltage changes as the temperature of the suspended and thermally isolated pi
APA, Harvard, Vancouver, ISO, and other styles
3

Ndube, Ncediwe. "Determination of fumonisins in maize by High Performance Liquid Chromatography with fluorescence and ultraviolet detection of o-phthaldialdehyde, naphthalene-2,3-dicarboxaldehyde and dansyl chloride derivatives." Thesis, University of the Western Cape, 2011. http://etd.uwc.ac.za/index.php?module=etd&action=viewtitle&id=gen8Srv25Nme4_2588_1320667169.

Full text
Abstract:
Fumonisins, carcinogenic mycotoxins produced by various Fusarium species, occur naturally in maize and maize-based food products. They are hazards for animal and human health as they cause cancer in rodents and have been associated with oesophageal cancer and neural tube defects in humans. The most abundant naturally occurring fumonisins analogues in maize are fumonisin B1, B2 and B3 (FB1, FB2 and FB3). For analytical determination, they mostly require suitable extraction, clean-up and pre or post-column derivatization together with reversed-phase HPLC separation. o- Phthaldialdehyde (OPA) had
APA, Harvard, Vancouver, ISO, and other styles
4

Liu, Fang. "Monte Carlo modeling of an x-ray fluorescence detection system by the MCNP code." Thesis, Georgia Institute of Technology, 2009. http://hdl.handle.net/1853/33959.

Full text
Abstract:
An x-ray fluorescence detection system has been designed by our research group for quantifying the amount of gold nanoparticles presented within the phantom and animals during gold nanoparticle-aided cancer detection and therapy procedures. The primary components of the system consist of a microfocus x-ray source, a Pb beam collimator, and a CdTe photodiode detector. In order to optimize and facilitate future experimental tasks, a Monte Carlo model of the detection system has been created by using the MCNP5 code. Specifically, the model included an x-ray source, a Pb collimator, a CdTe detecto
APA, Harvard, Vancouver, ISO, and other styles
5

Cook, Daniel W. "Chemometric Curve Resolution for Quantitative Liquid Chromatographic Analysis." VCU Scholars Compass, 2016. http://scholarscompass.vcu.edu/etd/4362.

Full text
Abstract:
In chemical analyses, it is crucial to distinguish between chemical species. This is often accomplished via chromatographic separations. These separations are often pushed to their limits in terms of the number of analytes that can be sufficiently resolved from one another, particularly when a quantitative analysis of these compounds is needed. Very often, complicated methods or new technology is required to provide adequate separation of samples arising from a variety of fields such as metabolomics, environmental science, food analysis, etc. An often overlooked means for improving analysis is
APA, Harvard, Vancouver, ISO, and other styles
6

Corbeil, Therrien Audrey. "Conception et modélisation de détecteurs de radiation basés sur des matrices de photodiodes à avalanche monophotoniques pour la tomographie d'émission par positrons." Thèse, Université de Sherbrooke, 2018. http://hdl.handle.net/11143/11909.

Full text
Abstract:
La tomographie d'émission par positrons (TEP) se distingue des autres modalités d'imagerie par sa capacité à localiser et quantifier la présence de molécules marquées, appelées radiotraceurs, au sein d'un organisme. Cette capacité à mesurer l'activité biologique des différents tissus d'un sujet apporte des informations uniques et essentielles à l'étude de tumeurs cancéreuses, au fonctionnement du cerveau et de ses maladies neurodégénératives et de la pharmacodynamique de nouveaux médicaments. Depuis les tout débuts de la TEP, les scientifiques rêvent de pouvoir utiliser l'information de te
APA, Harvard, Vancouver, ISO, and other styles
7

Pérez, Quiñones Carme. "Determinació d'anions d'interès en adoberia mitjançant cromatografia iònica." Doctoral thesis, Universitat Politècnica de Catalunya, 2017. http://hdl.handle.net/10803/458243.

Full text
Abstract:
The laboratories of the leather sector have the necessity to analyse anionic species in different samples. Although ionic chromatography is currently the best method for this analysis, until now, the processes based on it were non-existent. The purpose of this thesis is the development of innovative chromatographic methods, with an ion-exchange stationary phase and a PDA detector, to determine anions of interest in the leather industry. This study contains two blocks. The first one focuses on the determination of the anions that contribute to salinity and the second block corresponds to the qu
APA, Harvard, Vancouver, ISO, and other styles
8

Peprná, Tereza. "Anthokyanová barviva ve vybraném ovoci." Master's thesis, Vysoké učení technické v Brně. Fakulta chemická, 2011. http://www.nusl.cz/ntk/nusl-216775.

Full text
Abstract:
This diploma thesis is concerned with determination anthocyanins dyes in elderberry (Sambucus nigra L.). In theoretical part there is described general characterization of the plant, its chemical composition, short view of elderberry breeding and possibilities of usage in food and medical industry. Bigger attention is paid to anthocyanins dyes. There is described their characterization, occurrence, factors that have an impact on their stability. Biosynhesis of the pigments and metabolism, benefit effects and their usage in food chemistry are then shortly sumarized. Methods of determination of
APA, Harvard, Vancouver, ISO, and other styles
9

Broecker, Sebastian. "Aufbau und Anwendung einer Methode zur Identifizierung und Quantifizierung von Giften und deren Metaboliten in Blut und Haaren in der Systematischen Toxikologischen Analyse mittels Flüssigchromatographie-Quadrupol-Flugzeitmassenspektrometrie-Kopplung (LC-QTOF-MS)." Doctoral thesis, Humboldt-Universität zu Berlin, Mathematisch-Naturwissenschaftliche Fakultät I, 2012. http://dx.doi.org/10.18452/16461.

Full text
Abstract:
Die Systematische Toxikologische Analyse (STA) stellt auf Grund der großen Vielfalt und der ständigen Zunahme an toxikologisch relevanten Substanzen eine der größten Herausforderungen in der chemischen Analyse dar. In der vorliegenden Arbeit wurde daher die Eignung der Flüssigchromatographie in Kombination mit der Hybrid-Quadrupol-Flugzeitmassenspektrometrie (LC-QTOF-MS) für diesen Zweck untersucht. Dazu wurden eine Datenbank mit über 7360 und eine CID-Spektrenbibliothek mit mehr als 2720 toxikologisch relevanten Substanzen erstellt und geeignete Probenvorbereitungsmethoden entwickelt. Die Erp
APA, Harvard, Vancouver, ISO, and other styles
10

Houng, Chi-Lin, and 洪啟倫. "A Silicon-Base Photo-detector Diode Array." Thesis, 1996. http://ndltd.ncl.edu.tw/handle/19699967861858712908.

Full text
Abstract:
碩士<br>國立交通大學<br>電子研究所<br>84<br>This thesis deals with the design and implementation of a silicon-based photo-detector diode array with capacitive readout, surrounding contact and mesh electrode. The mesh electrode is used to prevent the reflection of incidentlight in long wavelength. In addition, the surrounding contact is used to reduce surface recombination. The detectors are tested by electrical measurement and illumination of different light sources. From the resultsof the electrical pr
APA, Harvard, Vancouver, ISO, and other styles
More sources

Book chapters on the topic "Photo Diode Array detector"

1

Birkoben, Tom, Mirko Hansen, Marina Ignatov, Martin Ziegler, and Hermann Kohlstedt. "A Bio-inspired Perceptual Decision-Making Circuit Based on the Hassenstein-Reichardt Direction Detector." In Springer Series on Bio- and Neurosystems. Springer International Publishing, 2023. http://dx.doi.org/10.1007/978-3-031-36705-2_13.

Full text
Abstract:
AbstractDecision-making belongs to one of the most prominent principles in the nerve system of living species. The crucial trade-off between time to decide (speed) and accuracy is essential for a creature to react to environmental stimuli and most importantly, relevant for survival. In-depth studies of coherent motion tasks in primates, based on two-choice decision experiments, led to a profound understanding of neuronal information processing and even bridged the gap to behavioural psychology. Three fundamental processing stages are needed to successfully perform a two-choice decision experim
APA, Harvard, Vancouver, ISO, and other styles
2

Kambara, Hideki, and Guohua Zhou. "DNA Analysis with a Photo-Diode Array Sensor." In Biosensors and Biodetection. Humana Press, 2009. http://dx.doi.org/10.1007/978-1-60327-567-5_19.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Buschmann, Claus, and Hartmut K. Lichtenthaler. "Complete Fluorescence Emission Spectra Determined During the Induction Kinetic Using a Diode-Array Detector." In Applications of Chlorophyll Fluorescence in Photosynthesis Research, Stress Physiology, Hydrobiology and Remote Sensing. Springer Netherlands, 1988. http://dx.doi.org/10.1007/978-94-009-2823-7_9.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Sowmya, K. B., Darshan Hegde, and Pratik Desai. "Beam Pattern Configuration Control Unit for a 24 × 24 Reconfigurable Array of Photo Detector-Based Pixels." In Lecture Notes in Networks and Systems. Springer Nature Singapore, 2023. http://dx.doi.org/10.1007/978-981-19-9228-5_50.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Jandik, Petr, Allan L. Heckenberg, Yair Egozy, Jeffrey Denoncourt, D. A. Stewart, and A. J. Brinklow. "Application of a Diode Array UV Detector for Chromatographic Evaluation of Processes Used in Making High Purity Water." In Recent Developments in Ion Exchange. Springer Netherlands, 1987. http://dx.doi.org/10.1007/978-94-009-3449-8_11.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

"photo diode array." In Dictionary Geotechnical Engineering/Wörterbuch GeoTechnik. Springer Berlin Heidelberg, 2014. http://dx.doi.org/10.1007/978-3-642-41714-6_161258.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Papadoyannis, Ioannis N., and H. G. Gika. "Peak Identification with a Diode Array Detector." In Encyclopedia of Chromatography. CRC Press, 2005. http://dx.doi.org/10.1201/noe0824727857-253.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Gika, H., and Ioannis Papadoyannis. "Peak Identification with a Diode Array Detector." In Encyclopedia of Chromatography, Second Edition. CRC Press, 2005. http://dx.doi.org/10.1201/noe0824727857.ch253.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

"Peak Identification with a Diode Array Detector." In Encyclopedia of Chromatography 2004 Update Supplement. CRC Press, 2004. http://dx.doi.org/10.1201/9781482298574-33.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Papadoyannis, Ioannis N., and H. G. Gika. "Peak Purity Determination with a Diode Array Detector." In Encyclopedia of Chromatography. CRC Press, 2005. http://dx.doi.org/10.1201/noe0824727857-254.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Conference papers on the topic "Photo Diode Array detector"

1

Choy, Wallace C. H. "Low-dimensional perovskite materials for efficient and stable light-emitting diodes and photon detection arrays." In Organic and Hybrid Light Emitting Materials and Devices XXVIII, edited by Tae-Woo Lee, Franky So, and Ji-Seon Kim. SPIE, 2024. http://dx.doi.org/10.1117/12.3028503.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Mori, Masahiko. "Optical bus systems using a cylindrical lens." In Optical Computing. Optica Publishing Group, 1995. http://dx.doi.org/10.1364/optcomp.1995.omc20.

Full text
Abstract:
In recent years, many kinds of optical board-to-board interconnection systems had been proposed and some of them were demonstrated[1-9]. Basic interconnection systems using laser diodes and photo detectors connected through free space[6] or Selfoc lenses[5] were shown. In these systems basic concept is based on sets of one-to-one interconnections with free space. Another approach is using fibers. To achieve fixed many-to-many interconnections, optical fiber ribbon, laser diode arrays and detector arrays are usefull[3].
APA, Harvard, Vancouver, ISO, and other styles
3

Hall, Donald N. B., Ian M. Baker, Vincent Isgar, Shane M. Jacobson, and Harald Weller. "A megapixel class HgCdTe linear mode avalanche photo-diode array for low background astronomy (Conference Presentation)." In High Energy, Optical, and Infrared Detectors for Astronomy VIII, edited by Andrew D. Holland and James Beletic. SPIE, 2018. http://dx.doi.org/10.1117/12.2314897.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Svedbrand, Daniel, Lars Allard, Magnus Pettersson, Pontus Köhler, Markus Henriksson, and Lars Sjökvist. "Optics detection using an avalanche photo diode array and the scanning-slit-method." In Technologies for Optical Countermeasures XVI, edited by David H. Titterton, Robert J. Grasso, and Mark A. Richardson. SPIE, 2019. http://dx.doi.org/10.1117/12.2531795.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Sheppard, Colin J. R., Alberto Tosi, Marco Castello, et al. "Image scanning microscopy (ISM) with a single photon avalanche diode (SPAD) array detector." In Optics, Photonics and Digital Technologies for Imaging Applications, edited by Peter Schelkens, Touradj Ebrahimi, and Gabriel Cristóbal. SPIE, 2018. http://dx.doi.org/10.1117/12.2309825.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Eriksen, Torkild, Ulf-Peter Hoppe, Eivind V. Thrane, and Tom A. Blix. "A Rayleigh lidar on rockets for studies of the middle atmosphere." In The European Conference on Lasers and Electro-Optics. Optica Publishing Group, 1998. http://dx.doi.org/10.1364/cleo_europe.1998.cmi6.

Full text
Abstract:
Two new rocket-borne Rayleigh lidar experiments were developed at the Norwegian Defence Research Establishment and launched from Andøya Rocket Range in October 97 and January 98. The aim of the experiments were to measure the neutral atmosphere number density and to study the dynamics of the middle atmosphere. A simulation programme for calculation of Rayleigh-scattered signal, background level and noise was used to investigate the performance of the instrument. Various configurations of transmitters and receivers were evaluated. For the transmitter, laser diode arrays and solid state lasers w
APA, Harvard, Vancouver, ISO, and other styles
7

Tsai, C. S., D. Y. Zang, and P. Le. "Multichannel Integrated Optic Device Modules in LinbO3 for Digital Data Processing*." In Integrated and Guided Wave Optics. Optica Publishing Group, 1988. http://dx.doi.org/10.1364/igwo.1988.tua5.

Full text
Abstract:
Numerous LinbO3-based integrated optic (IO) devices that utilize electrooptic (EO) or acoustooptic (AO) effect in either planar or channel waveguides have been constructed in recent years for future applications in optical communication and RF signal processing systems. However, most of these IO devices utilize a single or a small number of light sources and are, therefore, best suited to applications that involve a relatively small number of channels. In the meantime, it is of increasing interest to make IO devices that utilize a large number of light sources such as the diode laser array so
APA, Harvard, Vancouver, ISO, and other styles
8

Zhou, Shuoming, Chunhua Xie, Shiyin Zhao, et al. "Electro-Optical Scanner Using Phased Array Optical Systems." In Advances in Optical Imaging and Photon Migration. Optica Publishing Group, 1996. http://dx.doi.org/10.1364/aoipm.1996.mt130.

Full text
Abstract:
The problem of obtaining the precise localization of a hidden absorber in a highly scattering medium of large dimension has confronted the scientific community for a number of years. Optical methods can also use contrast agents and can identify a line from the tissue surface, including the localized contrast agent and hence the tumor. Localization of absorbers/fluorochromes deep within a highly scattering large body of tissue such as the human breast can be effected most precisely by photon diffusive waves (Yodh, physical Review) that are not only amplitude modulated in the MHz region. If they
APA, Harvard, Vancouver, ISO, and other styles
9

Maccarone, Aurora, Ulrich Steinlehner, Giulia Acconcia, Ivan Giuseppe Labanca, Ivan Rech, and Gerald S. Buller. "Time-correlated underwater depth imaging using an asynchronous linear single photon avalanche diode detector array." In Emerging Imaging and Sensing Technologies for Security and Defence V; Advanced Manufacturing Technologies for Micro- and Nanosystems in Security and Defence III, edited by Maria Farsari, John G. Rarity, Francois Kajzar, et al. SPIE, 2020. http://dx.doi.org/10.1117/12.2574476.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Sakamoto, Takahide, Toshimasa Umezawa, Guo-Wei Lu, et al. "Spatial Coherent Matched Detection Using High-Speed Two Dimensional Photo-Diode Array for Full-Channel Demultiplexing and Demodulation of Mode-Division-Multiplexed Signals." In 2017 European Conference on Optical Communication (ECOC). IEEE, 2017. http://dx.doi.org/10.1109/ecoc.2017.8346130.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Reports on the topic "Photo Diode Array detector"

1

อุดมกาญจนนันท์, พรพรรณ, та สุชาดา จูอนุวัฒนกุล. การตรวจวิเคราะห์สารมาลาไคต์กรีนและเมตะบอไลต์ลิวโคมาลาไคต์กรีนตกค้างในสัตว์น้ำเพาะเลี้ยงด้วยเทคนิค LC-MS/MS และเทคนิค HPLC-UV-VISIBLE : รายงานการวิจัย. จุฬาลงกรณ์มหาวิทยาลัย, 2007. https://doi.org/10.58837/chula.res.2007.57.

Full text
Abstract:
งานวิจัยนี้ได้พัฒนาวิธีวิเคราะห์MG และ LMG พร้อมกันในตัวอย่างสัตว์น้ำเพาะเลี้ยง ให้มีความถูกต้องแม่นยำสูง ด้วยการเตรียมตัวอย่างที่มีขึ้นตอนงายและรวดเร็วขึ้น ใช้เตาอบไมโครเวฟในการสกัดและคลีนอัพ และวิเคราะห์ MG และ LMG ด้วยเทคนิค LC-MS/MS มีสารคริสตัลไวโอเล็ต (Crystal violet, CV) เป็น internal standard ที่ ionpairs ดังนี้ : MG 329.3/208.2, 329.3/313.1, LMG331.3/165.4, 331.3/239.3 และ CV (internal standard) 372.2/356.3 วิธีวิเคราะห์อีกวิธีหนึ่งคือการตรวจวิเคราะห์มาลาไคต์กรีน ลิวโคมาลาไคต์กรีน คริสตัลไวโอเล็ต ลิวโคคริสตัลไวโอเล็ต ตกค้างในสัตว์น้ำเพาะเลี้ยง เช่น ปลา กุ้ง พร้อมกันด้วยเทคนิค HPLC-DAD
APA, Harvard, Vancouver, ISO, and other styles
2

อุดมกาญจนนันท์, พรพรรณ, та สุชาดา จูอนุวัฒนกุล. การตรวจวิเคราะห์สารมาลาไคต์กรีนและเมตะบอไลต์ลิวโคมาลาไคต์กรีนตกค้าง ในสัตว์น้ำเพาะเลี้ยง ด้วยเทคนิค LC-MS/MS และเทคนิค HPLC-UV-VISIBLE : รายงานการวิจัยฉบับสมบูรณ์. คณะวิทยาศาสตร์ จุฬาลงกรณ์มหาวิทยาลัย, 2008. https://doi.org/10.58837/chula.res.2008.37.

Full text
Abstract:
งานวิจัยนี้ได้พัฒนาวิธีวิเคราะห์ MG และ LMG พร้อมกันในตัวอย่างสัตว์น้ำเพาะเลี้ยง ให้มีความถูกต้องแม่นยำสูง ด้วยการเตรียมตัวอย่างที่มีขั้นตอนง่ายและรวดเร็วขึ้น ใช้เตาอบไมโครเวฟ ในการสกัดและคลีนอัพ และวิเคราะห์ MG และ LMG ด้วยเทคนิค LC-MS/MS มีสารคริสตัลไวโอเล็ต (Crystal violet, CV) เป็น internal standard ที่ ion pairs ดังนี้ : MG 329.3/208.2, 329.3/313.1, LMG 331 .3/165.4, 331.3/239.3 และ CV (internal standard) 372.2/356.3 วิเคราะห์ปริมาณด้วยวิธี standard addition method ร่วมกับ internal standard calibration method วิธีวิเคราะห์อีกวิธีหนึ่งคือการวิเคราะห์มาลาไคต์กรีน ลิวโคมาลาไคด์กรีน คริสตัลไว
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!