Academic literature on the topic 'Power switchgears'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Power switchgears.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Power switchgears"

1

Song, Jiajia, Jinbo Zhang, and Xinnan Fan. "Device for online monitoring of insulation faults in high-voltage switchgears." International Journal of Distributed Sensor Networks 17, no. 2 (2021): 155014772199928. http://dx.doi.org/10.1177/1550147721999284.

Full text
Abstract:
Partial discharges are the major cause of deterioration in the insulation characteristics of switchgears. Therefore, timely detection of partial discharge in switchgear and potential insulation faults is an urgent problem that needs to be addressed in the power supervision industry. In this study, a device was proposed for online monitoring of high-voltage switchgears based on pulse current method and ozone (O3) detection. The pulse current method obtains the PD signal by monitoring the phase holes on the switch indicator. Occurrence of a partial discharge in a certain phase leads to the production of a discharge pulse, which can be coupled out by a capacitive sensor. The current spectrum and the O3 produced by partial discharge were processed via fast Fourier transform for accurate diagnosis of the occurrence of partial discharge and its severity in switchgears. The proposed method allows for convenient acquisition of the partial discharge signal, simple installation of the device, and realization with inexpensive sensors.
APA, Harvard, Vancouver, ISO, and other styles
2

Abdikulova, Z. K., та E. O. Zhaparov. "СALCULATION AND CHOICE OF ELECTRIC CHART OF SUBSTATION OF THE КENTAU TRANSFORMER PLANT". BULLETIN Series of Physics & Mathematical Sciences 70, № 2 (2020): 141–48. http://dx.doi.org/10.51889/2020-2.1728-7901.21.

Full text
Abstract:
Electric supply system in enterprises must provide with electrical supply continuity and reliability as in normal and accidental regimes, quality electro energetic, production efficiency, so in connection with these in the article there have been analyzed work regimes of substations, studied electrical net scheme for Kentau Transformer Plant’s substation, calculated plant’s loads and short circuit currents and on the base of the calculated results curried out inspection for the chosen equipment. The number of connections, reliability of power supply and prospects for development are the determining factors for choosing the electrical scheme of high-voltage switchgears. You also need to take into account the need to conduct audits and tests of switches without interruption. In our case, we have four connections: two communication lines with electrical systems and two transformers. The distribution devices of the substation of the Kentau transformer plant are connected to the transformers according to a block scheme. Electrical installations are connected to the network transformer unit or receive backup power from another substation, since in case of failure of one network, both transformers can not work with the rest of the network. Based on this, measures are proposed for the reconstruction of the substation, with the replacement of the block diagram of the switchgear with the circuit for connecting the power transformer to the switchgear by a bus bridge. Offered measurements on reconstruction of the substation by replacing block scheme of switchgears to scheme of power transformer connection with DD bus bridge. Worked out main modernization problems of the substation switchgear, done calculation and selection of distributing bus bars for arranging switchgear.
APA, Harvard, Vancouver, ISO, and other styles
3

Lvovs, Aleksandrs, and Anna Mutule. "Estimation of Economical Validity of Usage Remote Operated Disconnectors for 110kV Switchgear Schemes From Optimal Reliability Level Point of View." Scientific Journal of Riga Technical University. Power and Electrical Engineering 28, no. 1 (2011): 31–36. http://dx.doi.org/10.2478/v10144-011-0005-y.

Full text
Abstract:
Estimation of Economical Validity of Usage Remote Operated Disconnectors for 110kV Switchgear Schemes From Optimal Reliability Level Point of ViewThe paper gives results of technical and economical calculations performed for estimation of validity of usage remote operated disconnectors for most commonly used 110kV switchgears from optimal reliability level point of view. Paper contains description of performed technical calculations - calculations of 110kV switchgear schemes' reliability level depending on type of disconnectors installed, and economical calculations, that are related with additional costs of Transmission System Operator and changes in total customer costs of power supply interruptions.
APA, Harvard, Vancouver, ISO, and other styles
4

Tan, Ren Shen, Ping Yang, and Peng He. "The Study on the Reliability of the Collection System of the Offshore Wind Farms Considering the Electrical Faults and Switchgear Configurations." Advanced Materials Research 621 (December 2012): 250–55. http://dx.doi.org/10.4028/www.scientific.net/amr.621.250.

Full text
Abstract:
With the rapid development of the offshore wind power, the design of the collection system for offshore wind farms attracts widespread attentions. In this paper, on the basis of analyzing the connection property and switchgear configurations of collection systems of offshore wind farms, a comprehensive reliability assessment model and the corresponding calculation method for the traditional switchgear configuration and the complete switchgear configuration are proposed. Taking an actual planned offshore wind farm for example, the reliability of two switchgear configurations are evaluated, and the sensitivity analyses on factors affecting the reliability of the wind farms such as the failure rate and MTTR of the cables and switchgears are performed. The result shows that the complete switchgear configuration is the better choice for offshore wind farms considering reliability indexes.
APA, Harvard, Vancouver, ISO, and other styles
5

Ļvovs, Aleksandrs, and Armands Staltmanis. "Selection of schemes of switchgears for new 110 kV substations." Scientific Journal of Riga Technical University. Power and Electrical Engineering 25, no. 25 (2009): 19–22. http://dx.doi.org/10.2478/v10144-009-0003-5.

Full text
Abstract:
Selection of schemes of switchgears for new 110 kV substationsRapid growth of Latvian economy before crisis resulted in rapid growth of electricity demand and reliability requirements are also increased. It's well known that object's influence on reliability of power supply increases growing nearer to power producing centre. This article gives analysis of reliability of switchgears for 110kV substations.
APA, Harvard, Vancouver, ISO, and other styles
6

Chen, Biyun, Haoying Chen, Yiyi Zhang, Junhui Zhao, and Emad Manla. "Risk Assessment for the Power Grid Dispatching Process Considering the Impact of Cyber Systems." Energies 12, no. 6 (2019): 1084. http://dx.doi.org/10.3390/en12061084.

Full text
Abstract:
Power grid dispatching is a high-risk process, and its execution depends on an available cyber system. However, the effects of cyber systems have not caught enough attention in current research on risk assessments in dispatching processes, which may cause optimistic risk results. In order to solve this problem, this paper proposes a risk assessment model that considers the impact of a cyber system on power grid dispatching processes. Firstly, a cyber-physical switchgear state model that integrates the reliability states of both cyber system functions and switchgears is proposed, based on the transition of switchgear states in the dispatching process. Then, the potential effects of each operating step on power grid states are analyzed considering the failure model of cyber-physical system (CPS) components. The risk probabilities and consequences of the power grid states are calculated to quantify the risk index. Finally, the workings and effectiveness of this model are illustrated using the IEEE Reliability Test System-1979.
APA, Harvard, Vancouver, ISO, and other styles
7

Kong, Xianguang, Jiantao Chang, Pei Wang, et al. "A novel approach of fault-influencing factors analysis for high-voltage switchgears quality supervision based on industrial big data." Proceedings of the Institution of Mechanical Engineers, Part B: Journal of Engineering Manufacture 233, no. 14 (2019): 2531–46. http://dx.doi.org/10.1177/0954405419839908.

Full text
Abstract:
Fault-influencing factors analysis is an important part of the quality supervision process. There are double functions for high-voltage switchgears that switch off and protect electric circuits in power transmission lines. Such devices have serious impact on power grid–operating efficiency, factory operation, and resident life, which will cause economic losses. As it was difficult for traditional methods to analyze fault-influencing factors accurately and comprehensively, a novel method based on industrial big data was proposed to analyze high-voltage switchgears fault-influencing factors in the process of quality supervision in this article, which integrated the qualitative and quantitative analyses method. In this model, the Classification Based on Multiple Class-Association Rules based on Gaussian Mixture Model as the qualitative analysis method was adapted to analyze the whole life cycle of fault-influencing factors of high-voltage switchgears comprehensively, and supplied fault-influencing factors with discrete interval value ranges. The logistic regression method based on qualitative analysis was constructed to calculate fault occurrence probability quantitatively, including the single-fault occurrence probability and the multiple-faults joint occurrence probability. In addition, the single-fault occurrence probability was used to modify the discrete interval value ranges calculated by the qualitative analysis method, which could make the ranges more accurately. Consequently, the proposed method could provide important reference for high-voltage switchgears operation maintenance, and it would be possible to design accurate maintenance plans before equipment failure. The final instance demonstrates the effectiveness of the proposed methodology.
APA, Harvard, Vancouver, ISO, and other styles
8

Illias, Hazlee Azil, Ming Ming Lim, Ab Halim Abu Bakar, Hazlie Mokhlis, Sanuri Ishak, and Mohd Dzaki Mohd Amir. "Classification of abnormal location in medium voltage switchgears using hybrid gravitational search algorithm-artificial intelligence." PLOS ONE 16, no. 7 (2021): e0253967. http://dx.doi.org/10.1371/journal.pone.0253967.

Full text
Abstract:
In power system networks, automatic fault diagnosis techniques of switchgears with high accuracy and less time consuming are important. In this work, classification of abnormal location in switchgears is proposed using hybrid gravitational search algorithm (GSA)-artificial intelligence (AI) techniques. The measurement data were obtained from ultrasound, transient earth voltage, temperature and sound sensors. The AI classifiers used include artificial neural network (ANN) and support vector machine (SVM). The performance of both classifiers was optimized by an optimization technique, GSA. The advantages of GSA classification on AI in classifying the abnormal location in switchgears are easy implementation, fast convergence and low computational cost. For performance comparison, several well-known metaheuristic techniques were also applied on the AI classifiers. From the comparison between ANN and SVM without optimization by GSA, SVM yields 2% higher accuracy than ANN. However, ANN yields slightly higher accuracy than SVM after combining with GSA, which is in the range of 97%-99% compared to 95%-97% for SVM. On the other hand, GSA-SVM converges faster than GSA-ANN. Overall, it was found that combination of both AI classifiers with GSA yields better results than several well-known metaheuristic techniques.
APA, Harvard, Vancouver, ISO, and other styles
9

Perfetto, Luca, and Gabriele D’Antona. "Experimental Results of Partial Discharge Localization in Bounded Domains." Sensors 21, no. 3 (2021): 935. http://dx.doi.org/10.3390/s21030935.

Full text
Abstract:
This work presents a novel diagnostic method to localize Partial Discharges (PDs) inside Medium Voltage (MV) and High Voltage (HV) equipment. The method is well suited for that equipment presenting a bounded domain with fixed Boundary Conditions (BCs) such as Oil-Filled Power Transformers (OFPTs), Air Insulated Switchgears (AISs), Gas Insulated Switchgears (GISs) or Gas Insulated Transmission Lines (GILs). It is based on Electromagnetic (EM) measurements which are used to reconstruct the EM field produced by the PD and localize the PD itself. The reconstruction and localization tasks are based on the eigenfunctions series expansion method which intrinsically accounts for the physical information of the propagation phenomenon. This fact makes the proposed diagnostic method very robust and accurate even in real and complex scenarios. The promising experimental results, obtained in two different test cases, confirmed the ability and powerfulness of the proposed PD localization method.
APA, Harvard, Vancouver, ISO, and other styles
10

Ramesh Kalaskar, Nikita, and Rajesh Holmukhe. "Report on Power Compensation and Total Harmonic Distortion level Analysis." International Journal of Electrical and Computer Engineering (IJECE) 6, no. 6 (2016): 2577. http://dx.doi.org/10.11591/ijece.v6i6.11221.

Full text
Abstract:
<p>In the chart of Indian science based industry, pharmaceutical industry is on top position. So it<em> </em>is essential to fulfil such critical requirement or demand, production should be with high speed. For such high production, using of software based machineries, electronic circuits are been used. By using such electronic based equipment’s and machineries, it is obvious day by day increasing non-linear load of the industry which lead to lagging power factor. In electric system nonlinear load with low power factor draws more current from source. So because of such high current drawn, life of switchgear, wire and other electrical equipment decreases. So due to large equipment and wasted energy, the electrical utilities company usually charge a higher cost to industrial customer for the constant logging power factor. To improving the lagging power factor, industry may prefer to install capacitor bank in series. But installation of capacitor power bank leads to the increment of total harmonics distortion level. In common plant, containing power factor correction capacitor, It is been seen that normal resonant frequency falls normally in the range of 5<sup>th</sup> to 13<sup>th</sup> harmonics. So this non-linear load leads to inject current at 5<sup>th</sup>, 7<sup>th</sup>, 11<sup>th</sup> and 13<sup>th</sup> harmonics. It will usually result on producing the problems with switchgears, damaged capacitor banks and failure to the electrical distribution system.</p>
APA, Harvard, Vancouver, ISO, and other styles

Dissertations / Theses on the topic "Power switchgears"

1

Squarzoni, Nicolò. "Metrological Characterization of a Low Power Voltage Transformer Embedded in Distribution Switchgears." Master's thesis, Alma Mater Studiorum - Università di Bologna, 2017.

Find full text
Abstract:
This paper presents an experimental campaign carried out on the Accusense voltage sensors for medium voltage distribution grids, developed in partnership with Altea Solutions. The project involves G&W Electric Company, switchgear manufacturer, Altea Solutions, sensor manufacturer, and the University of Bologna. The entire project has been carried out by the senior graduate power engineering student Nicolo’ Squarzoni, under supervision of Nenad Uzelac and Blair S. Kerr from G&W Electric side and under supervision of Prof. Lorenzo Peretto from both Altea Solutions and University of Bologna side. The aim of the project was to design and build highly accurate measuring systems in order to carry out accuracy tests on multiple samples of Accusense active and passive sensors under different operating conditions, eventually collecting results for comparison and marketing purposes.
APA, Harvard, Vancouver, ISO, and other styles
2

Petrič, Peter. "Návrh uzemňovače 80 kA/3 s pro odpojovač generátoru." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2018. http://www.nusl.cz/ntk/nusl-376995.

Full text
Abstract:
This master thesis is focused on the design of earthing switch for the indoor three pole generator disconnector from IVEP, a.s. The main task of the theoretical part of the master thesis was mechanical and electrical calculations on the contact system and the design of two variants of earthing switch construction. It has been proposed two variants of earthing switch construction. The first variant included three earthing knives for each pole of earthing switch and the other variant included two earthing knives for each pole. The aim of the practical part of this diploma thesis was to create a model of the earthing switch for generator disconnector, to simulate the heating of the contact system by passing the short-circuit current and to prepare the production documentation. For modeling, calculations and simulations were used Autodesk Inventor 2018, Matlab and Ansys Workbench.
APA, Harvard, Vancouver, ISO, and other styles
3

Gunda, Rahul. "Performance analysis of high power photoconductive switch at elevated temperature." Diss., Columbia, Mo. : University of Missouri-Columbia, 2005. http://hdl.handle.net/10355/4310.

Full text
Abstract:
Thesis (M.S.)--University of Missouri-Columbia, 2005.<br>The entire dissertation/thesis text is included in the research.pdf file; the official abstract appears in the short.pdf file (which also appears in the research.pdf); a non-technical general description, or public abstract, appears in the public.pdf file. Title from title screen of research.pdf file viewed on (July 13, 2006) Includes bibliographical references.
APA, Harvard, Vancouver, ISO, and other styles
4

Fallier, William F. "Analysis of system wide distortion in an integrated power system utilizing a high voltage DC bus and silicon carbide power devices." Thesis, Monterey, California. Naval Postgraduate School, 2007. http://hdl.handle.net/10945/3006.

Full text
Abstract:
This research investigates the distortion on the electrical distribution system for a high voltage DC Integrated Power System (IPS). The analysis was concentrated on the power supplied to a propulsion motor driven by an inverter with simulated silicon carbide switches. Theoretically, silicon carbide switches have the advantage of being able to withstand a very large blocking voltage and carry very large forward currents. Silicon carbide switches are also very efficient due to their quick rise and fall times. Since silicon carbide switches can withstand high voltage differentials and switch faster than silicon switches, the switching effects on the electrical distribution system were investigated. The current state of silicon carbide power electronics was also investigated. This research quantifies the current and voltage distortion over various operating conditions. A system model was developed using Matlab, Simulink, and SimPowerSystems. The model consisted of a synchronous generator supplying a rectifier and inverter set driving an induction motor. This induction motor simulates the propulsion motor for a Navy ship. This model had a DC link voltage of 10 kV in order to simulate future Navy IPS systems. The current and voltage distortion were compared to MIL STD 1399 and IEEE STD 519 and 45.<br>Contract Number: N62271-97-G-0026
APA, Harvard, Vancouver, ISO, and other styles
5

Fessler, Christopher Michael Nunnally W. C. "Improved contact design for the SiC photo-switch used in high power applications." Diss., Columbia, Mo. : University of Missouri--Columbia, 2007. http://hdl.handle.net/10355/5080.

Full text
Abstract:
The entire thesis text is included in the research.pdf file; the official abstract appears in the short.pdf file; a non-technical public abstract appears in the public.pdf file. Title from PDF of title page (University of Missouri--Columbia, viewed September 10, 2009). Thesis advisor: William Nunnally. Includes bibliographical references.
APA, Harvard, Vancouver, ISO, and other styles
6

Sözer, Esin Bengisu Kirkici Hulya. "Gaseous discharges and their applications as high power plasma switches." Auburn, Ala, 2008. http://repo.lib.auburn.edu/EtdRoot/2008/SPRING/Electrical_and_Computer_Engineering/Thesis/Sozer_Esin_45.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Kelkar, Kapil S. "Silicon carbide as a photoconductive switch material for high power applications." Diss., Columbia, Mo. : University of Missouri-Columbia, 2006. http://hdl.handle.net/10355/4469.

Full text
Abstract:
Thesis (Ph. D.) University of Missouri-Columbia, 2006.<br>The entire dissertation/thesis text is included in the research.pdf file; the official abstract appears in the short.pdf file (which also appears in the research.pdf); a non-technical general description, or public abstract, appears in the public.pdf file. Title from title screen of research.pdf file (viewed on August 3, 2007) Includes bibliographical references.
APA, Harvard, Vancouver, ISO, and other styles
8

LeChien, Keith Robert. "Implementation of the University of Missouri Terawatt Test Stand and the study of a large, multichanneling, laser tirggered gas switch." Diss., Columbia, Mo. : University of Missouri-Columbia, 2006. http://hdl.handle.net/10355/4432.

Full text
Abstract:
Thesis (Ph.D.)--University of Missouri-Columbia, 2006.<br>The entire dissertation/thesis text is included in the research.pdf file; the official abstract appears in the short.pdf file (which also appears in the research.pdf); a non-technical general description, or public abstract, appears in the public.pdf file. Title from title screen of research.pdf file viewed on (February 27, 2007) Vita. Includes bibliographical references.
APA, Harvard, Vancouver, ISO, and other styles
9

Nilsson, Daniel, and Sebastian Berg. "Standardisering och modularisering av lågspänningsställverken i ABB:s HVDC-stationer." Thesis, University West, Division of Electrical and Automation Engineering, 2010. http://urn.kb.se/resolve?urn=urn:nbn:se:hv:diva-2588.

Full text
Abstract:
<p>Den här rapporten undersöker möjligheterna att standardisera och modulariseralågspänningsställverken i ABB:s HVDC-stationer. Anläggningarna har idag heltkundanpassade lösningar, vilket tar för lång tid att projektera för att kunna svara mot denökade efterfrågan på HVDC-lösningar.Arbetet baseras på tretton stationer i åtta pågående och avslutade projekt. Dessa skiljer sigtill storlek, lokalisering, ålder, dokumentation och stationstyp.För att kunna erhålla en korrekt men samtidigt överskådlig bild överlågspäninngsställverkets laster, granskades varje stations dokumentation. Informationensammanställdes i en databas, som visade de belastningar som var ständigt återkommande.Arbetet visar att det är möjligt att standardisera valda delar av lågspänningsställverken, docktas ingen hänsyn till vare sig storleks- eller kostnadsökning. Arbetet behandlar de mestfrekvent förekommande brytarstorlekarna för de typiska lasterna.Det standardförslag som tagits fram har anpassats för att täcka de brytarstorlekar somförekommit för de typiska lasterna i stationerna. För strömriktartransformatorerna erbjudstvå varianter av skåp, medan det för övriga laster endast förekommer ett alternativ.En alternativ lösning på problemet skulle kunna vara att ta fram en standard för varjestationstyp. Detta förutsätter dock ett större antal projekt av varje typ än de som tagits medi detta arbete.</p><br><p>This thesis investigates the possibilities to standardize and modularize the low-voltageswitchgear in ABB’s HVDC-stations. The reason for this is that the customized solutionthey use today take too much engineering and production time to meet the expectedincrease of projects.The report is based on thirteen stations in eight different closed or ongoing projects. Theselection was based on the station size, geographical location, commissioning year andstation type.In order to obtain a correct representation of the loads in the low-voltage switchgear, therelevant station documentation was reviewed and compiled in a database. The data wasthen analyzed to determine the most frequently occurring loads and their characteristics.The thesis shows that it’s possible to standardize some components in the low-voltageswitchgear. However, this report doesn’t take into consideration any possible increase oftotal size and cost. It also shows the most frequent sizes of the circuit breakers for each ofthe common loads.The standard proposition for the common loads was developed to cover all the occurringsizes of the circuit breakers in the stations. For the converter transformers coolingequipment there’s two different cubicles to choose from, while the remaining loads islimited to a single alternative.An alternative solution could be to develop a standard for each occurring station type.However, this would require that the data from a larger number of projects, for all stationtypes, are reviewed and compiled.</p>
APA, Harvard, Vancouver, ISO, and other styles
10

Svoboda, Tomáš. "Optimalizace procesu práškového lakování s výsledkem snížení pracnosti konečné úpravy komponent plynem izolovaných rozvoden - GIS." Master's thesis, Vysoké učení technické v Brně. Fakulta strojního inženýrství, 2016. http://www.nusl.cz/ntk/nusl-241879.

Full text
Abstract:
The diploma thesis deals with the optimization of powder-coating process resulting in a reduction of labor intensity during finishing components in gas insulated switchgear (GIS). The thesis is divided into five main chapters that describe characteristic and function of gas insulated switchgear (GIS), the theory of powder-coating, including mechanical and chemical pretreatment of surfaces, the studies of contemporary quality of coating process in the company ABB s.r.o. with classification of components of GIS according to their function. This chapter also contains detailed analysis of section of coating process during the processing of selected parts (housing and conductor). The thesis also contains detailed studies of masking of surfaces at coating parts, specifies the most common defects and determines the main cause presented in a well-arranged chart, design, description and realization of optimization solutions with selection and evaluation of final version. An economic comparison of contemporary condition of powder-coating process with designed optimization solution is stated at the end of the thesis.
APA, Harvard, Vancouver, ISO, and other styles

Books on the topic "Power switchgears"

1

Vitkovitsky, Ihor. High power switching. Van Nostrand Reinhold Co., 1987.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
2

Blower, R. W. Distribution switchgear: Construction, performance, selection, and installation. Edited by Reeves E. A. Collins, 1986.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
3

Mogilevskiĭ, G. V. Gibridnye ėlektricheskie apparaty nizkogo napri͡a︡zhenii͡a︡. Ėnergoatomizdat, 1986.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
4

International Conference on Developments in Distribution Switchgear (2nd 1986 London, England). Second International Conference on Developments in Distribution Switchgear, 14-16 May 1986. IEE, 1986.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
5

IEEE Power Engineering Society. Power Systems Relaying Committee. IEEE guide for protective relay applications to power transformers. Institute of Electrical and Electronics Engineers, 2000.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
6

International Conference on Future Trends in Distribution Switchgear (3rd 1990 Institution of Electrical Engineers). Third International Conference on Future Trends in Distribution Switchgear, 23-25 April 1990. The Institution, 1990.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
7

IEEE Pulsed Power Conference (6th 1987 Arlington, Va.). Digest of technical papers. Edited by Bernstein Bernard H, Turchi Peter J, and IEEE Electron Devices Society. Institute of Electrical and Electronics Engineers, 1987.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
8

IEEE International Pulsed Power Conference (8th 1991 San Diego, Calif.). Digest of technical papers. Edited by Prestwich Kenneth R, White Roger, and IEEE Electron Devices Society. IEEE, 1991.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
9

Filatov, A. A. Perekli͡u︡chenii͡a︡ v ėlektro-ustanovkakh 0,4-10 kV raspredelitelʹnykh seteĭ. Ėnergoatomizdat, 1991.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
10

IEEE International Pulsed Power Conference (9th 1993 Albuquerque, N.M.). Digest of technical papers: Ninth IEEE International Pulsed Power Conference, Hyatt Regency Hotel, Albuquerque, New Mexico, USA, June 21-23, 1993. Edited by Prestwich Kenneth R, Baker William L. 1943-, IEEE Electron Devices Society, and IEEE Nuclear and Plasma Sciences Society. Institute of Electrical and Electronics Engineers, 1993.

Find full text
APA, Harvard, Vancouver, ISO, and other styles

Book chapters on the topic "Power switchgears"

1

Manesis, S. A. "Computer and Expert System Aided 3D Design of Power Switchgear Arrangements." In Engineering Systems with Intelligence. Springer Netherlands, 1991. http://dx.doi.org/10.1007/978-94-011-2560-4_73.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Allen, N. P., T. Harris, C. J. Jones, and S. Lane. "Switchgear." In Newnes Electrical Power Engineer's Handbook. Elsevier, 2005. http://dx.doi.org/10.1016/b978-075066268-0/50007-x.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Hewitson, L. G., Mark Brown, and Ramesh Balakrishnan. "Switchgear (busbar) protection." In Practical Power System Protection. Elsevier, 2005. http://dx.doi.org/10.1016/b978-075066397-7/50016-0.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

"Switchgear Combinations." In Analysis and Design of Low-Voltage Power Systems. Wiley-VCH Verlag GmbH & Co. KGaA, 2005. http://dx.doi.org/10.1002/352760233x.ch9.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

"Medium-voltage switchgear." In Practical Power Distribution for Industry. Elsevier, 2004. http://dx.doi.org/10.1016/b978-075066396-0/50002-5.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Agrawal, K. C. "Switchgear and Controlgear Assemblies." In Industrial Power Engineering Handbook. Elsevier, 2001. http://dx.doi.org/10.1016/b978-075067351-8/50091-x.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

"Switchgear and Motor Control Centers." In Industrial Power Distribution. John Wiley & Sons, Inc., 2016. http://dx.doi.org/10.1002/9781119065180.ch7.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Khan, Shoaib. "Switchgear, Circuit Breakers, and Motor Control Center." In Industrial Power Systems. CRC Press, 2018. http://dx.doi.org/10.1201/9781420015393-7.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

"Switchgear, Circuit Breakers, and Motor Control Center." In Industrial Power Systems. CRC Press, 2007. http://dx.doi.org/10.1201/9781420015393.ch7.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

"Electric Generator Switchgear & Controls." In Combined Heating, Cooling & Power Handbook. Fairmont Press, 2002. http://dx.doi.org/10.1201/9780203912218.ch27.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Conference papers on the topic "Power switchgears"

1

Wu, Ching-Hui, Tsu-Jen Lin, and Tsu-Mu Kao. "Study of a Station Blackout Event in the PWR Plant." In 10th International Conference on Nuclear Engineering. ASMEDC, 2002. http://dx.doi.org/10.1115/icone10-22757.

Full text
Abstract:
On March 18, 2001, a PWR nuclear power plant located in the Southern Taiwan occurred a Station BlackOut (SBO) event. Monsoon seawater mist caused the instability of offsite power grids. High salt-contained mist caused offsite power supply to the nuclear power plant very unstable, and forced the plant to be shutdown. Around 24 hours later, when both units in the plant were shutdown, several inadequate high cycles of bus transfer between 345 kV and 161 kV startup transformers degraded the emergency 4.16 kV switchgears. Then, in the Train-A switchgear room of Unit 1 occurred a fire explosion, when the degraded switchgear was hot shorted at the in-coming 345 kV breaker. Inadequate configuration arrangement of the offsite power supply to the emergency 4.16 kV switchgears led to loss of offsite power (LOOP) events to both units in the plant. Both emergency diesel generators (EDG) of Unit 1 could not be in service in time, but those of Unit 2 were running well. The SBO event of Unit 1 lasted for about two hours till the fifth EDG (DG-5) was lined-up to the Train-B switchgear. This study investigated the scenario of the SBO event and evaluated a risk profile for the SBO period. Guidelines in the SBO event, suggested by probabilistic risk assessment (PRA) procedures were also reviewed. Many related topics such as the re-configuration of offsite power supply, the addition of isolation breakers of the emergency 4.16 kV switchgears, the betterment of DG-5 lineup design, and enhancement of the reliability of offsite power supply to the PWR plant, etc., will be in further studies.
APA, Harvard, Vancouver, ISO, and other styles
2

Hussain, G. A., M. Shafiq, and M. Lehtonen. "Predicting arc faults in distribution switchgears." In 2016 17th International Scientific Conference on Electric Power Engineering (EPE). IEEE, 2016. http://dx.doi.org/10.1109/epe.2016.7521722.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Kieffel, Yannick, Francois Biquez, Philippe Ponchon, and Todd Irwin. "SF6 alternative development for high voltage Switchgears." In 2015 IEEE Power & Energy Society General Meeting. IEEE, 2015. http://dx.doi.org/10.1109/pesgm.2015.7286096.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Yang, Juqing, Jiaoyue Liu, and Hongying Wang. "Study of hydraulic fault diagnosis based on power switchgears." In Mechanical Engineering and Information Technology (EMEIT). IEEE, 2011. http://dx.doi.org/10.1109/emeit.2011.6022861.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Duan, Xiongying, Yan Guo, Minfu Liao, Guanxiong Lv, Fubiao Li, and Jiyan Zou. "Research of precision time protocol in intelligent switchgears." In 2017 4th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST). IEEE, 2017. http://dx.doi.org/10.1109/icepe-st.2017.8188972.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Shirai, Koji, Tsukasa Miyagi, Mikimasa Iwata, Koji Tasaka, and Junghoon Ji. "Demonstrative HEAF (High Energy Arcing Fault) Fire Tests of High and Low Voltage Switchgears of Nuclear Power Plants." In 2018 26th International Conference on Nuclear Engineering. American Society of Mechanical Engineers, 2018. http://dx.doi.org/10.1115/icone26-82177.

Full text
Abstract:
High Energy Arcing Faults (HEAF) have the potential to cause extensive damage to the failed electrical components and distribution systems along with adjacent equipment and cables within the zone of influence (ZOI). Furthermore, the significant energy released during HEAF event can act as an ignition source to other components within the area of the HEAF. In Japan, during the Great East Japan Earthquake occurred in 2011, the seismic induced HEAF fire event, which induced the whole damage of the multiple high voltage switchgears, was observed in Onagawa Nuclear Power Plant (NPP). In response, in August 2017, the NRA (Nuclear Regular Authority) in Japan amended the safety requirement for the power supply to consider the influence of the successive fire due to the HEAF event (hereinafter HEAF fire event). Therefore, it is urgently necessary to establish the design criteria to prevent the HEAF fire event, and enhance the experiment data of the HEAF fire event. In order to estimate the total arc energy during the HEAF event and obtain the threshold value to prevent the HEAF fire for the existed non-arc proof electrical cabinets, several series of three-phase internal arc tests with high (6.9kV class) and low (480V class) voltage electrical cabinets were executed. We executed internal arc tests with full scale high/low voltage metal-enclosed switchgear components (non-arc proof type, copper bus conductor), and evaluated arc energy, the mechanical damage of the cabinet and the surrounding equipment due to the impulsive pressure and the possibility of successive fire occurrence. In case of high voltage switchgear, when the arcing energy exceeded 25.3MJ, successive fire was identified. Especially, in the case where the arc flash was discharged in the circuit breaker room, a 2-second arcing duration in a three-phase short-circuit current with 18.9kA (measured arcing energy over 40MJ) caused successive fire which required extinguishment. On the other hand, in case of low voltage power center, when the arcing energy exceeded 19MJ, successive fire was identified. According to these demonstrative tests, this paper presents the evaluation method to estimate total arc discharge energy during the HEAF event for high and low voltage electrical cabinets.
APA, Harvard, Vancouver, ISO, and other styles
7

Massaoudi, Mohamed, Ahmad Darwish, Shady S. Refaat, Haitham Abu-Rub, and Hamid A. Toliyat. "UHF Partial Discharge Localization in Gas-Insulated Switchgears: Gradient Boosting Based Approach." In 2020 IEEE Kansas Power and Energy Conference (KPEC). IEEE, 2020. http://dx.doi.org/10.1109/kpec47870.2020.9167534.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Varivodov, V. N., D. I. Kovalev, A. M. Timofeev, and N. V. Krupenin. "Application of shielded solid insulation for the complete switchgears at high voltage." In 2017 International Conference on Modern Power Systems (MPS). IEEE, 2017. http://dx.doi.org/10.1109/mps.2017.7974402.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Jialin, Liu, Abdul Haseeb Memon, Fu Xiongxiong, and Xiaohua Wang. "Fluorinated Nitrile as a Potential Substitute of SF6 for ARC Interruption in Switchgears." In 2018 International Conference on Power System Technology (POWERCON). IEEE, 2018. http://dx.doi.org/10.1109/powercon.2018.8601762.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Liu, Yitao, He Hong, Xucheng Lu, et al. "Application experience of SF6-Free 72.5kV hybrid-gas-insulated-switchgears in China." In 2017 4th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST). IEEE, 2017. http://dx.doi.org/10.1109/icepe-st.2017.8188844.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Reports on the topic "Power switchgears"

1

Toman, G., R. Gazdzinski, and K. Schuler. Aging Management Guideline for commercial nuclear power plants: Electrical switchgear. Final report. Office of Scientific and Technical Information (OSTI), 1993. http://dx.doi.org/10.2172/10177879.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Journeyman wireman electrocuted after contacting energized switchgear components at power plant - West Virginia, March 14, 1994. U.S. Department of Health and Human Services, Public Health Service, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, 1994. http://dx.doi.org/10.26616/nioshface9410.

Full text
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!