To see the other types of publications on this topic, follow the link: Pressió intraocular.

Dissertations / Theses on the topic 'Pressió intraocular'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 dissertations / theses for your research on the topic 'Pressió intraocular.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

Ferrer, Mallol Elisa. "Caracterització electrofisiològica del canal de K+ d'alta conductància dependent de Ca2+ (BKCa) a la cèl·lula trabecular: modulació per l'stretch i la hipòxia." Doctoral thesis, Universitat de Barcelona, 2004. http://hdl.handle.net/10803/1127.

Full text
Abstract:
Les malalties que causen ceguesa total o parcial afecten a milions de persones arreu del món. Una de les principals causas de ceguesa és el glaucoma, malaltia caracteritzada per un augment de la pressió intraocular (IOP) i una pèrdua de visió perifèrica. <br/><br/>La fisiopatologia del glaucoma està estretament relacionada amb la fisiologia de l'humor aquós, fluid contingut a les cambres oculars (anterior i posterior). Des de la cambra anterior, l'humor aquós s'eliminarà a través de: 1) la via uveoescleral, que és minoritària, i 2) la via convencional o trabecular, on la major part de l'humor aquós (aprox. 80%) s'elimina travessant la xarxa trabecular cap el canal d'Schlemm i les venes aquoses. <br/><br/>L'humor aquós té dues funcions: 1) nodrir les estructures avasculars (còrnia i cristal·lí) i 2) mantenir la IOP dins dels marges fisiològics (15-16 mmHg). Quan s'altera l'equilibri entre la producció i l'evacuació de l'humor aquós, l'humor aquós s'acumula i la IOP augmenta. La xarxa trabecular és un teixit d'estructura similar a una esponja organitzat en diferents regions i en contacte directe amb el canal d'Schlemm. La part més propera al canal d'Schlemm és la que presenta major resistència al pas de l'humor aquós. Alteracions en aquesta via suposaran un augment de la resistència i, en conseqüència, un augment de la IOP. <br/><br/>La contractilitat cel·lular i la regulació del volum de la cèl·lula trabecular, són dos mecanismes claus en la regulació de la permeabilitat de la xarxa trabecular. Aquests dos mecanismes induirien deformacions a la membrana que activarien canals mecanosensibles.<br/><br/>Un d'aquests canals mecanosensibles és el canal de K+ d'alta conductància dependent de Ca2+ (BKCa), que es caracteritza per la seva activació per voltatges despolaritzants i està modulat pel calci intracel·lula i del qual s'ha demostrat la seva mecanosensibilitat en diferents teixits.<br/><br/>Per aquesta raó, s'ha caracteritzat electrofisiològicament el canal BKCa a la cèl·lula trabecular i s'ha estudiat la seva modulació per diferents factors, entre ells l'stretch mecànic. El canal BKCa ha demostrat ésser mecanosensible augmentant la seva probabilitat d'obertura tant per canvis en la tensió de la membrana cel·lular com per increments del volum cel·lular (swelling). <br/><br/>En altres sistemes el canal està modulat per la pressió parcial d'oxigen (PO2), de manera que estímuls hipòxics disminueixen l'activitat del canal produïnt despolaritzacions com en les cèl·lules del cos carotidi. A l'ull, l'humor aquós aporta oxigen a les estructures avasculars i a la xarxa trabecular. Els valors de PO2 de l'humor aquós són més baixos (aprox. 55 mmHg) que en altres teixits més oxigenats (aprox. 95 mmHg). Per aquesta raó qualsevol procés que produeixi hipòxia a la cambra anterior tindrà un efecte més acusat. <br/><br/>Per aquests motius s'ha estudiat quins mecanismes poden existir a les cèl·lules trabeculars per respondre a estats hipòxics. Els resultats obtinguts mostren com els corrents mitjançats pel canal BKCa disminueixen quan les cèl·lules trabeculars es tracten amb una solució hipòxica. Aquesta disminució dels corrents totals també s'observa en cèl·lules incubades en condicions d'hipòxia (5% O2).<br/><br/>La hipòxia produeix alteracions a la mobilització del calci intracel·lular ([Ca2+]i) en diferents tipus cel·lulars. A les cèl·lules trabeculars s'ha estudiat l'efecte de la hipòxia sobre la [Ca2+]i i s'ha observat com la hipòxia modifica la resposta en relació al [Ca2+]i quan s'apliquen diferents substàncies vasoactives (bradikinina, endotel·lina-1) que influeixen sobre l'evacuació de l'humor aquós i que augmenten la [Ca2+]i a la cèl·lula trabecular. La hipòxia produeix entre d'altres efectes, un augment de la [Ca2+]i basal respecte les cèl·lules control (normòxiques) i disminueix l'increment de la [Ca2+]i produït per les substàncies agonistes.<br><i>SUBJECT: Electrophysiological characterization of a large conductance Ca2+-activated K+ channel (BKCa) in trabecular meshwork cells: modulation by membrane stretch and hypoxia<br/><br/>TEXT: The understanding of the physiology of the trabecular meshwork has advanced in the last few years, however few ionic channels have been characterized in this tissue. The large conductance Ca2+-activated K+ channel (BKCa) has been identified in the trabecular meshwork cells but its function is still unknown. BKCa channel is voltage dependent and its activity is modulated by intracellular calcium concentration ([Ca2+]i), with different functions depending on the cell type. In excitable cells it controls neuronal excitability, participates in neurotransmitter release and modulates contractile tone in vascular smooth muscle. In non-excitable cells it has been described its participation in cell volume regulation and its modulatory effect on different substances that mobilize [Ca2+]i.<br/><br/>Besides [Ca2+]I, other substances such as cGMP or nitric oxide modulate the activity of BKCa channel in the trabecular meshwork. In other tissues, BKCa channel has shown mechanosensitive properties and it has also been described how its activity is modified by low PO2 values (hypoxia). Since trabecular meshwork cells are subjected to intraocular pressure and that aqueous humor contained in the anterior chamber presents PO2 values lower than other tissues, it is important to study the effects of these modulators on BKCa channel activity which will have a direct effect on the physiology of the trabecular meshwork.</i>
APA, Harvard, Vancouver, ISO, and other styles
2

Abad, Adán Elena. "Caracterización de la entrada de Ca2+ "capacitativa" en células trabeculares." Doctoral thesis, Universitat de Barcelona, 2009. http://hdl.handle.net/10803/1139.

Full text
Abstract:
El glaucoma es una de las principales causas de ceguera parcial o total e irreversible en el mundo. Los avances en su estudio revelan la compleja naturaleza multifactorial de la enfermedad que consiste finalmente en un daño del nervio óptico (neuropatía).<br/><br/>El incremento de la presión intraocular (PIO) prolongado en el tiempo es uno de los factores de riesgo más significativo y reconocido para el desarrollo de esta enfermedad. Este incremento puede causar lesiones en el nervio óptico por deformación mecánica y/o cambios fisiopatológicos en una zona de la retina dónde se sitúan las células ganglionares del nervio. La PIO es resultado del balance entre la producción y drenaje del humor acuoso. El humor acuoso es un fluído derivado de plasma sanguíneo, producido en los procesos ciliares, que baña la cámara anterior del ojo para alimentar sus estructuras avasculares y mantener la tensión mecánica adecuada del globo ocular, y es drenado, principalmente, a través de la malla trabecular o trabéculo. Se sabe que el incremento de la contracción de este tejido implica una disminución en la facilidad de drenaje del humor acuoso y un aumento de la PIO. <br/><br/>La presencia incrementada de endotelina-1 (ET-1), potente vasoconstrictor, en humor acuoso de pacientes glaucomatosos plantea algunas cuestiones que abordamos en este trabajo de tesis doctoral. Estas sustancias (endotelina-1, bradiquinina) son agonistas de receptores acoplados a proteína Gq que activan la vía de la fosfolipasa C (vía PLC- inositol trifosfato y diacilglicerol) y podrían tener un efecto contráctil, también, sobre la malla trabecular dado que activan la depleción de Ca2+ intracelular. <br/><br/>El objetivo principal de este trabajo de tesis doctoral ha sido identificar y caracterizar un tipo de corriente de entrada de calcio extracelular (vía principal de entrada de calcio en células no excitables), llamada corriente 'capacitativa' de Ca2+ o dependiente del vaciado de Ca2+ de los depósitos intracelulares (ICCE o ISOC) y su posible implicación en la función de contracción/relajación de las células trabeculares y en consecuencia del tejido. <br/><br/>Identificamos distintos tipos de corrientes capacitativas de Ca2+ en cultivos primarios de células trabeculares en modelo bovino y humano, tras el estímulo con sustancias vasoconstrictoras y tapsigargina. Para la caracterización farmacológica usamos bloqueadores típicos de la ICCE (2-APB, lantánidos, SKF96365) y registramos la evolución de la activación de ICCE mediante registros electrofisiológicos, testeando nuevamente bloqueadores conocidos de este tipo de corrientes. Observamos cómo en algunos casos las corrientes capacitativas son selectivas para el Ca2+ y en otros (vía PLC), en cambio, aparecían formas de corrientes catiónicas no selectivas.<br/><br/>Detectamos mediante western blot la presencia de proteínas de canal tipo TRPC (TRPC1 y TRPC4) que forman canales catiónicos en membrana y pueden ser activados vía PLC, posibles mediadores de la ICCE en células trabeculares.<br/><br/>La técnica de microscopía de tracción permitió estudiar la evolución de la contracción de la célula por estímulo con sustancias vasoconstrictoras. Obtuvimos medidas cuantitativas y la distribución de fuerzas en la célula durante la contracción. Estos resultados revelaron que la contracción inducida por estas sustancias depende primeramente de la depleción de Ca2+ intracelular y curiosamente, el Ca2+ extracelular regula, disminuyendo, la intensidad de esa contracción. <br/><br/>Mostramos en este trabajo, la existencia de la ICCE en células trabeculares y sugerimos el papel de esta vía de entrada de Ca2+ como señal autoreguladora del proceso de contracción celular y su posible efecto en la función evacuadora del tejido.<br><i>High concentrations of endothelin-1 (ET-1), one of the most potent vasoconstrictor peptide, has been found in the aqueous humor of glaucomatous eyes. It is said that vasoconstrictor substances as ET-1 or bradykinin could induce contraction of trabecular meshwork tissue (TM) and decreases the aqueous humour outflow facility increasing the intraocular pessure (IOP) and the risk of glaucoma. The aim of this study is the calcium signalling, mainly, the characterization of the calcium influx/entry in these cells, the identification of capacitative calcium entry (ICCE) or, also called, store-operated calcium entry (ISOC) in trabecular cells and their role on cell contraction.<br/><br/>We found these currents in cell culture of bovine and human trabecular cells and in a human cell line, too, using fluorescence techniques and electrophysiology recordings. They are stimulated by the intracellular Ca2+ depletion from stores via IP3 (bradykinin, endothelin) and blocking the Ca2+-pump of endoplasmic reticulum (thapsigargin). These currents are blocked or inhibited by certain lanthanids ions, 2-APB or SKF96365. <br/><br/>Western blots showed the presence of certain members of the Transient Receptor Potential (TRP) channels subfamily C (TRPC1 and TRPC4). The pharmacology of inhibition of the Ca2+ influx suggests the TRPC channels and store-operated calcium channels as mediators. <br/><br/>The measurements of cell traction evolution by traction microscopy maps stimulating with vasoconstrictor substances were useful to determine store-operated Ca2+ entry may not be necessary for cell contraction in TM cells but may contribute to modulate cell contractility and so, the aqueous humour outflow facility. </i>
APA, Harvard, Vancouver, ISO, and other styles
3

Méndez, Ulrich Jorge Luis. "Control percibido y reactividad de la presión intraocular." Doctoral thesis, Universitat Autònoma de Barcelona, 2013. http://hdl.handle.net/10803/133295.

Full text
Abstract:
En la presente tesis se realiza una aproximación desde la perspectiva de la Psicofisiología y de la Psicología de la Salud al estudio de la reactividad de la presión intraocular (PIO) al estrés agudo de tipo cognitivo y al estrés psicosocial. La inclusión de un estresor psicosocial en el estudio de la reactividad de la PIO constituye una de las novedades de este trabajo, dada la ausencia de literatura previa en la que empleen este tipo de tareas. Además se evalúa por primera vez el posible papel modulador que ejercen los juicios de evaluación cognitiva, en términos de percepción de control desde la teoría transaccional de Lazarus y Folkman (1986), y la teoría cognitivo social postulada por Albert Bandura. Algunos de los hipotéticos determinantes evaluados en los 3 estudios que componen esta tesis (1 experimento y 2 estudios de campo) son: la competencia percibida, la percepción de amenaza y la percepción de reto). También se evalúa el posible efecto que la ansiedad rasgo y estado podrían desempeñar en la modulación de esta reactividad. Por otra parte se realiza una caracterización preliminar de un fenómeno análogo al conocido como efecto de Hipertensión de bata blanca (HBB) que nosotros denominamos Hipertensión ocular de bata blanca (HOBB), consistente en una habituación de la PIO, que presenta un patrón decreciente cuando se obtienen medidas sucesivas de este parámetro. Además, se realiza una aproximación a algunos de los hipotéticos determinantes cognitivos de este fenómeno como la percepción de control y de amenaza y la ansiedad rasgo y estado. Los resultados de este trabajo sugieren que la PIO es reactiva tanto al estrés cognitivo como psicosocial, siendo el valor del incentivo (en este caso la valencia emocional asociada a un eventual fracaso en la tarea) una variable que podría ejercer un papel modulador de esta respuesta, y que la percepción de control y de amenaza constituyen dos posibles variables explicativas de la HOBB. En la discusión final de esta tesis se comentan las limitaciones de los estudios que la componen, y se reflexiona respecto a la pertinencia de extrapolar este tipo de estudios al ámbito clínico, dada la importancia que estos hallazgos sugieren la necesidad de evaluar el papel del estrés en la evaluación y tratamiento de la hipertensión ocular y del glaucoma.<br>This thesis is an approach from the perspective of Psychophysiology and Health Psychology to the study of the reactivity of intraocular pressure (IOP) to acute cognitive and psychosocial stress, The inclusion of a psychosocial stressor in the field of the IOP reactivity is one of the novelties of this work, given the lack of previous literature employing these type of tasks. It also evaluates for a first time, the potential the modulating role of cognitive evaluation judgments in terms of perceived control from the transactional theory of Lazarus and Folkman (1986 ), and social cognitive theory postulated by Albert Bandura (1977). Some of the hypothetical determinants evaluated in the 3 studies of this thesis (one experiment and two field studies) are: perceived competence, perceived threat and perceived challenge). We also evaluate the possible effect that state and trait anxiety might play in modulating this reactivity. Moreover, we make a preliminary characterization of a phenomenon analogous to white coat hypertension (WCH), that we call white coat ocular hypertension (WCOH), consisting in a habituation of IOP, which has a decreasing pattern when successive measurements are obtained for this parameter. Furthermore, it is an approach to some of the hypothetical cognitive determinants of this phenomenon as the perception of threat and control and state and trait anxiety. The results of this study suggest that IOP is reactive both cognitive and psychosocial stress. The value incentive value (in this case the emotional valence associated with a potential failure in the experimental task) seems to be a variable that could exert a modulating role on this response, and that the perception of control and threat are two possible explanatory variables for WCOH. In the final discussion of this thesis we expose the limitations of our studies, and we suggest the importance of extrapolating these studies to the clinical setting, given the importance of these findings, that suggest the need to evaluate the role of stress in the evaluation and treatment of ocular hypertension and glaucoma.
APA, Harvard, Vancouver, ISO, and other styles
4

Fossey, Marcelo Andre. "Tonometro eletronico para a medida da pressão intraocular." [s.n.], 1985. http://repositorio.unicamp.br/jspui/handle/REPOSIP/260015.

Full text
Abstract:
Orientador: Wang Binseng<br>Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Campinas<br>Made available in DSpace on 2018-07-15T11:51:29Z (GMT). No. of bitstreams: 1 Fossey_MarceloAndre_M.pdf: 1942478 bytes, checksum: be673589961b28b0f1ac699750d312aa (MD5) Previous issue date: 1985<br>Resumo: Devido às graves implicações sociais do glaucoma, e ao fato dele ser relativamente imperceptível no início, é necessário a avaliação da pressão intra-ocular (PIO) toda vez que se efetua o "check-up"., pois pressões prolongadas acima de 21 mmHg podem causar alteração do campo visual e, se não tratado em tempo, cegueira ao paciente. Atualmente os tonômetros utilizados no Pais são importados, apresentando alto custo, baixa precisao (tonômetro de Goldmann) e pouca confiabilidade (tonômetros eletrônicos). Foi projetado e construido um tonômetro eletrônico, com materiais e componentes facilmente encontráveis no mercado nacional. A PIO é medida por uma ponta de prova, no centro da qual existe um pino rigidamente acoplado a uma cerâmica piezoelétrica, que ao ser deformada pela PIO produz uma tensão elétrica e, ao se detetar eletronicamente a condição de aplanação, é registrado o valor da PIO num display digital. Para aumentar a confiabilidade, o tonômetro foi montado num suporte com o formato de revólver, com dois suportes laterais. Este tonômetro pode ser utilizado com.o paciente na posição vertical ou reclinado, sem o auxílio da lâmpada de fenda.<br>Abstract: The grave social consequences of glaucoma and the fact its onset is relatively imperceptivable make evaluation of the intraocular pressure (IOP) essential at each Iredical examination. Prolonged IOPs above 21 nmHg may cause alterations in the visual field and, if not treated, blindness in the patient. At the present time, alI tonometers used in Brazil are irnported. 1n general, they present either high cost and low precision (Goldman tonometers) or little reliability (electronic tonometers). An electronic tonometers was designed and built using materiaIs and corrponents available in Brazil. The IOP is measured with a probe at the center of which exists a pin fixed rigidly onto a piezoelectric transducer, whose deforrnation by tpe IOP produces an electric signal. As the cornea is depressed by the probe, the applanation, condition is detected electronically and the value of IOP thus detected is displayed digitally. To provide reliable measurerrents, the tonometer was mounted in front of a pistol-like holder with two supports to be positioned on, the facial banes. The instrument may be used with the patient in any position without the need af a slit lamp.<br>Mestrado<br>Mestre em Engenharia Elétrica
APA, Harvard, Vancouver, ISO, and other styles
5

Roubeix, Christophe. "Intérêt des cellules souches mésenchymateuses dans la thérapie du glaucome." Thesis, Paris 6, 2014. http://www.theses.fr/2014PA066535/document.

Full text
Abstract:
Le glaucome est une neuropathie optique associée à une augmentation de la pression intraoculaire (PIO). L’élévation de la PIO est due à la dégénérescence progressive du trabéculum. Les traitements antiglaucomateux vise à réduire la PIO, cependant il n’existe aucun traitement ciblant la dégénérescence du trabéculum. Les cellules souches mésenchymateuses (CSMs) sont utilisées comme outils thérapeutiques dans différentes pathologies dégénératives. Elles sécrètent un panel de molécules qui sont décrit comme atténuant les processus dégénératifs. L’objectif de ce travail a été d’évaluer l’intérêt des CSMs dans la prise en charge du glaucome. La caractérisation des CSMs ont été mis au point à partir de culture primaire de moelle osseuse de rat. En parallèle, un modèle expérimental de glaucome par cautérisation des veines épisclérales (EVC) a été réalisé. Nous nous sommes intéressés à l’effet de l’injection intracamérulaire des CSMs dans ce modèle. Les CSMs sont retrouvées incorporées aux tissus autour et dans le trabéculum. Les résultats obtenus in vivo montrent une diminution de la PIO par l’injection des CSMs préservant ainsi les cellules ganglionnaires périphériques de la rétine (CGRs). Par une approche in vitro, nous avons également caractérisé les effets du sécrétome des CSMs sur les cellules impliquées dans la pathologie glaucomateuse: les cellules trabéculaires et les cellules ganglionnaires de la rétine. Ces résultats ont permis de montrer que l’injection intracamérulaire de CSMs permettrait de protéger la fonction de régulation de la PIO et de protéger les CGRs dont la mort est responsable de la diminution de l’acuité visuelle chez le patient glaucomateux<br>Glaucoma is a sight-threatening retinal neuropathy associated with elevated intraocular pressure (IOP) due to degeneration and fibrosis of the trabecular meshwork (TM). Glaucoma medications aim to reduce IOP without targeting the specific TM pathology, which could explain treatment failure observed in some cases. Bone-marrow mesenchymal stem cells (MSCs) are used today in various clinical studies to treat various degenerative processes. Here, we investigated the potential of MSC therapy in an ocular hypertension model. We demonstrated a rapid and long-lasting in vivo effect of MSC transplantation that significantly reduced IOP in hypertensive eyes induced by episcleral vein cauterization (EVC). MSCs were found located to the ciliary processes and the TM and are able to survive at these places. Enumeration of retinal ganglion cells (RGCs) on whole flat-mounted retina highlighted a protective effect of MSCs on RGC death. In vitro, the effect of MSC-conditioned medium (MSC-CM) on both the primary human trabecular meshwork (hTM) and RGCs showed that MSC-CM promotes: (i) hTM survival by activating the antiapoptotic pathway, Akt, (ii) hTM decontractibility as analyzed by the decrease in myosin phosphorylation and (iii) inhibition of TGF-β2-dependent profibrotic phenotype acquisition in hTM, (iiii) RGC survival and neuritic outgrowth in vitro. Finally, MSCs injection in the ocular anterior chamber in a rat model of ocular hypertension provides a neuroprotective effect in the glaucoma pathophysiology directly on RGC and indirectly via TM protection. These results originally demonstrate that MSCs represent promising tool for treating ocular hypertension and retinal cell degeneration
APA, Harvard, Vancouver, ISO, and other styles
6

Nakachi, Higuchi Sadae. "Cambios en la presión intraocular post cirugía de catarata con implante de lente intraocular en cámara posterior en ojos no glaucomatosos, Hospital Nacional Daniel Alcides Carrión (Programa Sight First) durante los meses de enero a mayo del 2010." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2013. https://hdl.handle.net/20.500.12672/14541.

Full text
Abstract:
Publicación a texto completo no autorizada por el autor<br>Determina si existió variación de la presión intraocular (PIO) en pacientes no glaucomatosos sometidos a cirugía de catarata con implante de lente intraocular en la cámara posterior en el Hospital Nacional Daniel Alcides Carrión (Programa Sight First) durante los meses de enero a mayo del 2010.Fue un estudio descriptivo, tipo retrospectivo. Se identificaron 111 pacientes, 49 fueron varones (44,1%) y 62 mujeres (55,9%), predominando el grupo de 68 a 80 años (62,2%), con media de 72,9 años. La media de PIO pre quirúrgica fue 15,8 ± 1,8 mm Hg y la PIO postoperatoria fue de 14 ± 2,9 mm Hg. (p=0,000). La variación de la presión fluctuó entre -14 y 9 mm Hg, con media de - 1,8 ± 3,5 mm Hg (p=0,000), no dependió del tipo de cirugía (p=0,959) ni de la presencia de pseudoexfoliación (p=0,628); pero sí del grado de catarata (p=0,033) y del nivel de PIO preoperatoria, con la que se relacionó inversamente (p=0,0000). Hubo una tendencia con respecto a la profundidad de la cámara anterior (p=0,056). Se encontró reducción significativa de la PIO que no dependió del tipo de cirugía, pero sí del nivel de PIO prequirúrgica y grado de catarata. Hubo una tendencia con respecto a la profundidad de la cámara anterior.<br>Trabajo académico
APA, Harvard, Vancouver, ISO, and other styles
7

Aptel, Florent. "Applications des ultrasons focalisés de haute intensité au traitement du glaucome." Thesis, Lyon 1, 2011. http://www.theses.fr/2011LYO10344.

Full text
Abstract:
Le glaucome est une pathologie fréquente principalement due à une élévation de la pression intraoculaire. La pression intraoculaire est le fruit d’un équilibre entre la production du liquide qui remplit la portion antérieure de l’œil - l’humeur aqueuse - et son élimination. Les traitements du glaucome peuvent donc agir selon deux mécanismes : la réduction de la production d’humeur aqueuse par la destruction partielle ou l’inhibition pharmacologique du corps ciliaire, structure responsable de la production de l’humeur aqueuse, ou la facilitation de l’évacuation de l’humeur aqueuse en dehors de l’oeil. De nombreuses méthodes physiques peuvent être utilisées pour détruire le corps ciliaire : lasers, cryothérapie, micro-ondes, etc. Néanmoins, toutes ces méthodes ont deux inconvénients majeurs qui limitent leur utilisation : elles sont peu sélectives de l’organe à traiter, entraînant souvent des dommages des structures adjacentes, et elles présentent une relation effet-dose très inconstante, empêchant de prévoir avec précision l’effet du traitement. L’objectif de ce travail de thèse est le développement d’un dispositif ultrasonore de coagulation du corps ciliaire circulaire, comprenant 6 transducteurs piézoélectriques en forme de segments de cylindre, et générant 6 lésions segmentaires s’inscrivant dans un anneau de diamètre similaire à celui formé par le corps ciliaire. Les expérimentations animales ont montré une nécrose de coagulation sélective des zones du corps ciliaire traitées par le dispositif. Le premier essai clinique a montré que cette méthode était bien tolérée et permettait une réduction importante, prédictible et maintenue dans le temps de la pression intraoculaire<br>Glaucoma is a common disease mainly due to an increase of the pressure inside the eye. Intraocular pressure is the result of a balance between the production of liquid that fills the anterior part of eye - aqueous humor - and its elimination. All treatments for glaucoma aim to reduce the intraocular pressure and can therefore have two mechanisms of action: reducing aqueous humor production by the partial destruction or medical inhibition of the ciliary body - anatomical structure responsible for the production of aqueous humor - or facilitating the evacuation of aqueous humor out of the eye. Several physical methods can be used to destroy the ciliary body: laser, cryotherapy, microwave, etc. However, all these methods have two major drawbacks limiting their use: they are non-selective of the organ to be treated, often resulting in damage to the adjacent structures, and they have an unpredictable dose-effect relationship, preventing to accurately predict the treatment effect. The objective of this thesis is the development of a circular ultrasonic device incorporating six transducers producing high-intensity focused ultrasound for a selective coagulation of the ciliary body. A circular device with 6 piezoelectric transducers having a geometry of a segment of a cylinder was used to generate six segmental lesions entering in a ring of diameter similar to that formed by the ciliary body. Animal experiments have shown a selective coagulation necrosis of the treated ciliary body. The first clinical trial in humans showed that this method was well tolerated and allowed a significant, predictable and sustained reduction of the intraocular pressure
APA, Harvard, Vancouver, ISO, and other styles
8

Niño, Montero José Segundo. "Comparación de la tonometría de contorno dinámico (Pascal) y tonometría de aplanación (Goldmann) en relación al grosor corneal y curvatura corneal." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2009. https://hdl.handle.net/20.500.12672/2456.

Full text
Abstract:
Objetivo: Determinar la diferencias en las mediciones de tonometría de contorno dinámico (TCD) y la tonometría de aplanación (TAG) al relacionarlas con el grosor y la curvatura corneal. Materiales y métodos: Estudio transversal, comparativo. Se obtuvo una muestra por conveniencia, esto incluyó a 116 ojos de pacientes que acudieron al programa social del Instituto de Ojos Oftalmosalud, sin patología ocular demostrada, entre los meses de febrero a Abril del 2009. Se tomaron medidas del grosor, curvatura corneal, presión intraocular por TCD y TAG Resultados: La edad promedio de los participantes fue 55 años, el 52.58% varones. La media de la PIO por contorno dinámico fue 19.3 mm Hg y de la tonometría de aplanación 16.32 mm Hg, existiendo diferencias significativas entre ambas mediciones de PIO (p menor 0,0006). El grosor de la córnea central por paquimetría fue 539.4 en promedio y la media de la curvatura corneal en dioptrías de 43.28. Las comparaciones de las medias de la PIO de la TAG y TCD según el grosor corneal central (GCC) son significativas en las medidas menores a 500 micras (p menor 0.000001). Según la curvatura corneal se mantienen estas diferencias de manera significativa, es mayor con el TCD. Conclusiones: La tonometría de contorno dinámico sobreestima significativamente la PIO comparada con la tonometría de aplanación. La PIO evaluada con ambos instrumentos comparadas con el grosor corneal muestran diferencias significativas, siendo similares en córneas entre 500 a 549 micras.<br>--- Objective: To determine the differences in the measurements of Dynamic contour tonometry and Goldmann applanation tonometry in relation with the thickness and the corneal curvature. Methodology: Study transverse, a sample was obtained by convenience, included 116 patients’ eyes went to the Oftalmosalud social program, without ocular pathology, showed through February to April, 2009. They took measures of the thickness, corneal curvature, pressure for CDT and AGT. Results: The age average of the participants was of 55 years, 52.58% males. The stocking of the IOP one for contour dinamic was 19.3 mmHg and for applanation tonometry 16.32mmHg, existing significant differences among both mensurations of IOP (p less 0, 0006). The thickness of the central cornea for paquimetry was 539.4 on the average and the stocking of the corneal bend in dioptrias of 43.28. The comparisons of the stockings of the IOP one of AGT and CDT according to the thickness corneal power station (CCT) are significant in the measures smaller to 500 microns (p less 0.000001). According to the corneal curvature stays with significant differences ways being bigger with CDT. Conclusions: The tonometry of contour dinamic overestimates the IOP one compared with the applanation tonometry significantly. The IOP one evaluated with both instruments compared with the corneal thickness shows significant differences, being similar in corneas among 500 to 549 microns.<br>Tesis
APA, Harvard, Vancouver, ISO, and other styles
9

Lau-Choleón, García Juan Carlos. "Aplicación de la técnica quirúrgica de la trabeculectomía para el tratamiento del aumento de la presión intraocular en caninos." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2002. https://hdl.handle.net/20.500.12672/1235.

Full text
Abstract:
El presente trabajo es una adaptación de la técnica quirúrgica de trabeculectomía para el tratamiento del glaucoma canino. Para tal fin se utilizaron 5 caninos de distintos sexos, razas y edades, con una historia clínica de glaucoma. Ellos fueron intervenidos en la Clínica de Animales Menores de la Facultad de Medicina Veterinaria de la Universidad Nacional Mayor de San Marcos, empleándose la técnica quirúrgica de trabeculectomía, la cual consiste en crear una nueva vía de drenaje del humor acuoso. En cada uno de los casos, se demostró que dicha técnica es una alternativa, rápida, poco costosa y confiable para el tratamiento resolutivo de esta patología. Con el fin de verificar su eficacia se realizaron evaluaciones oftalmológicas post-quirúrgicas. Los hallazgos mostraron en todos los casos una importante disminución de la presión intraocular. Al comparar las presiones intraoculares antes y después de la intervención quirúrgica se encontró una diferencia estadística significativa con un nivel de confiabilidad del 99%. Se concluye que la técnica quirúrgica de trabeculectomía puede ser usada en la resolución del aumento de la presión intraocular en caninos.<br>The present work in an adjustment of the surgical technique of trabeculectomy for the treatment of the canine glaucoma. To accomplish it, 5 canines of different sex, races and age, with clinical history of glaucoma were used. They were treated in the Clinic of Small Animals of the Faculty of Veterinary Medicine of the National University of San Marcos. The surgical technique of trabeculectomy permitted to find a new way of draining of the aqueous humor. In each of the cases, there was demonstrated that the technique is a quick, cheap and reliable alternative for treatment of this pathology. In order to verify its efficiency, postsurgical evaluations were done. In all the case the findings showed an important decrease of the intraocular pressure. When comparing the intraocular pressures before an after the surgical intervention. There was found a significative statistical difference, with 99% of reliance. It is concluded that the surgical technique of trabeculectomy can be used successfully in the treatment of the increase of he intraocular pressure in canine.<br>Tesis
APA, Harvard, Vancouver, ISO, and other styles
10

Claros, Chacaltana Flor Diana Yokoay. "Avaliação da pressão intraocular em chinchilas (chinchilla Lanigera) de diferentes faixas etárias utilizando tonometria de rebote." reponame:Biblioteca Digital de Teses e Dissertações da UFRGS, 2013. http://hdl.handle.net/10183/76540.

Full text
Abstract:
A aferição da pressão intraocular (PIO) é fundamental durante o exame oftálmico. Objetivou-se estabelecer os valores de referência da PIO de chinchilas de diferentes faixas etárias utilizando o tonômetro de rebote. A PIO foi aferida ao longo do dia às 7, 12 e 19 horas utilizando o tonômetro de rebote (Tonovet®). As chinchilas foram subdivididas em três grupos com 12 animais cada, considerando as idades, designados por GI (animais com idade entre dois a seis meses), GII (com idade entre 20 e 34 meses) e GIII (animais com idade entre 37 e 135 meses). Previamente, foram realizados teste da lágrima de Schirmer, prova da fluoresceína, biomicroscopia com lâmpada de fenda e oftalmoscopia indireta em todos os animais. O valor médio da pressão intraocular encontrado foi 2,49 ± 0,56 mmHg, os valores médios para o grupo I foi de 2,47±0,581 mmHg, no grupo II de 2,47±0,581 mmHg e no grupo III de 2,51±0,531 mmHg. Não foram encontradas diferenças significativas entre a idade e a PIO (P = 0,756). Não foram encontradas diferenças significativas entre as horas do dia e a PIO (P = 0,415). Não foram encontradas diferenças significativas entre os sexos (P = 0,857). Os valores da PIO em chinchilas não sofrem alterações decorrentes do sexo e da idade dos animais. Não ocorre influência do ritmo circadiano na PIO de chinchilas.<br>The assessment of intraocular pressure (IOP) is essential for the ocular examination. The purpose of this study was to establish reference values of intraocular pressure chinchillas (Chinchilla lanigera) of different age groups. Thirty-six Chinchillas were divided in three groups of 12 animals each, considering the ages designated by GI (animals aged two to six months), GII (aged between 20 and 34 months) and GIII (animals aged between 37 and 135 months). Intraocular pressure was measured at 7, 12 and 19 hours. Tear production was measured, fluorescein test, slit-lamp biomicroscopy and indirect ophthalmoscopy in all animals and IOP was measured using the rebound tonometer (Tono Vet®) set on the P (undefined species) setting, with measurements obtained from each eye. No abnormalities were found on ophthalmic examination. The mean (±SD) of IOP was 2.49 ± 0.56 mmHg, with a range of 2-4 mmHg. The mean (±SD) of IOP for group I, II and III were 2.47 ± 0.581 mmHg, 2.47 ± 0.581 mmHg and 2,51 ± 0.531 mmHg, respectively. No significant differences were found between age and IOP and no significant differences were found between the hours of day and IOP. No significant differences were found between the genders. The IOP in chinchillas is unchanged between genders and age of the animals. The circadian rhythm is not influenced by IOP in chinchillas.
APA, Harvard, Vancouver, ISO, and other styles
11

Díaz, Sánchez Miriam Giovanna. "Presión intraocular y presión de perfusión ocular en pacientes en hemodiálisis del Hospital Nacional Dos de Mayo." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2012. https://hdl.handle.net/20.500.12672/15061.

Full text
Abstract:
Publicación a texto completo no autorizada por el autor<br>Evalúa la presión intraocular y la presión de perfusión ocular durante un hemodiálisis. Setenta y dos ojos de 40 pacientes fueron evaluados 30 minutos antes de comenzar la sesión de hemodiálisis, 1 hora , 2 horas , 3 horas después de la iniciación y una hora después de terminada la hemodiálisis. La presión intraocular se evaluó utilizando un Perkins. La presión sistólica y diastólica se midió con un esfigmomanómetro. Paquimetría se estimó para obtener la presión intraocular corregida. La presión de perfusión ocular se estimó midiendo la diferencia entre 2/3 de la presión arterial media y los valores de la presión intraocular. Encuentra que no hubo diferencia estadísticamente significativa en la presión de perfusión ocular (p=0,327), la presión intraocular (p=0,13) y la paquimetría (p=0,87) en los cinco puntos de estudio. Hubo diferencia estadísticamente significativa en la presión arterial media durante toda la sesión de hemodiálisis (p = 0,024). El análisis de los valores extremos de la presión de perfusión ocular mostró variación estadísticamente significativa (p = 0,028). Concluye que los resultados apoyan la idea de que hay cambios significativos en la presión de perfusión ocular y la presión arterial media durante la sesión de hemodiálisis.<br>Tesis
APA, Harvard, Vancouver, ISO, and other styles
12

Godenèche, Benoît. "Glaucome évolutif à pression intra-oculaire normalisée. Etude à partir de l'enregistrement sur le nycthémère de la tension oculaire couplé à la tension artérielle." Bordeaux 2, 1997. http://www.theses.fr/1997BOR23078.

Full text
APA, Harvard, Vancouver, ISO, and other styles
13

CURT, ISABELLE. "Etude des variations de la pression intraoculaire au cours de la coelioscopie." Clermont-Ferrand 1, 1993. http://www.theses.fr/1993CLF1MS14.

Full text
APA, Harvard, Vancouver, ISO, and other styles
14

Pereira, Fabiana Quartiero. "Comparação entre o tonômetro de rebote (Tonovet) e o novo tonômetro de aplanação (Tono-pen a via) durante curva diurna da pressão intraocular de coelhos adultos." reponame:Biblioteca Digital de Teses e Dissertações da UFRGS, 2010. http://hdl.handle.net/10183/27277.

Full text
Abstract:
A determinação da pressão intraocular (PIO) é fundamental no exame oftálmico. Atualmente, novos tonômetros, baseados em diferentes princípios, estão sendo continuamente desenvolvidos. O objetivo deste estudo foi estabelecer os valores de referência da PIO de coelhos adultos, sem efeito de tranquilizantes, mensurada com o tonômetro de rebote (Tonovet) e o de aplanação (Tono-Pen Avia). Também foi preconizada a mensuração da PIO ao longo do dia nesta espécie e a comparação dos resultados obtidos com os dois tonômetros. A PIO foi aferida ao longo do dia (6h, 9h, 12h, 15h e 18h) em 38 coelhos (76 olhos) da raça Nova Zelândia Branca, adultos, com idade média de seis meses, machos ou fêmeas, com massa corporal média de 3,5kg. Previamente, foi realizado teste da lágrima de Schirmer, prova da fluoresceína, biomicroscopia com lâmpada de fenda e oftalmoscopia direta em todos os animais. A tonometria de rebote foi realizada primeiro e, decorridos 10 minutos, foi instilado colírio anestésico e realizada a tonometria de aplanação. A PIO obtida utilizando as duas técnicas foi comparada estatisticamente. A média da PIO com o Tonovet foi de 9,51 ± 2,62 mmHg (variação de 3- 23mmHg) e 15,44 ± 2,16 mmHg (variação de 8 – 26mmHg) com o Tono-Pen Avia. Houve diferença estatística significante entre os valores obtidos com os dois tonômetros (P < 0,001). A relação entre os dois tonômetros foi representada através da equação de regressão linear: y = 0,4923x + 10,754 (y= Tonovet e x= Tono-Pen Avia). No início do dia foram registradas PIOs mais elevadas, mas a média dos valores ao longo do dia, com ambos os aparelhos, foi estatisticamente o mesmo (p = 0,086). O valor do coeficiente de correlação obtido foi r2= 0,357. Os resultados demonstram que o Tono-Pen Avia é mais variável e superestima a PIO de coelhos quando comparado ao Tonovet. Nas primeiras horas do dia, a PIO de coelhos foi mais alta que nos demais horários, independentemente do tonômetro utilizado.<br>The determination of intraocular pressure (IOP) is crucial in eye examination. Currently, new tonometers based on different principles are being continuously developed. The objective was to establish reference values of IOP of adults rabbits without the effect of tranquilizers, utilizing the rebound tonometer (Tonovet ) and the applanation tonometer (Tono-Pen Avia) for measurements. It also aimed to advocate the measurement of IOP throughout the day in this species and compare the results obtained with the two tonometers. The IOP was measured throughout the day (6h, 9h, 12h, 15h and 18h) in 38 New Zealand White rabbits (76 eyes), adults, males or females, with mean weight of 3.5kg and an average age of six months. Previously, the Schirmer tear test, fluorescein test, biomicroscopy with slit lamp and direct ophthalmoscopy were performed in all animals. First, the rebound tonometry was performed and after a minimum of 10 minutes anesthetic drops were instilled and applanation tonometry was carried out. IOP obtained using the two techniques was compared by statistical analysis. The average IOP was 9.51 ± 2.62 mmHg (range 3 - 23 mmHg) and 15.44 ± 2.16 mmHg (range 8 – 26mmHg), with Tonovet and Tono-Pen Avia, respectively. Statistic significant difference between the two tonometers was (P <0.001). The linear regression equation that describes the relationship between the two tonometers was: y = 0.4923 x + 10.754 (y= Tonovet e x= Tono-Pen Avia). Earlier in the day, higher IOPs were recorded, but the average behavior of IOP throughout the day with both devices was statistically the same (p = 0.086). The value of the correlation coefficient was r2 = 0.357. The results show that the Tono-Pen Avia is more variable and overestimates the IOP of rabbits when compared with the Tonovet. In the early hours, the IOP of rabbits was higher than at other times, regardless of the tonometer used.
APA, Harvard, Vancouver, ISO, and other styles
15

Nunes, Mariana Pinto. "Effects of methadone on intraocular pressure in dogs and cats." Master's thesis, Universidade de Lisboa, Faculdade de Medicina Veterinária, 2018. http://hdl.handle.net/10400.5/16470.

Full text
Abstract:
Dissertação de Mestrado Integrado em Medicina Veterinária<br>Objective: The purpose of this study was to determine the effects of methadone as a solo-agent of anaesthetic premedication, on intraocular pressure (IOP) in dogs and cats undergoing both elective surgeries or diagnostic procedures. Methods: The study group was composed of 32 and 5 cats. The baseline IOP (T0) of the subjects were registered before IV methadone at the 0.2 mg kg-1 dosage. IOP variations were registered ten (T10) and twenty (T20) minutes after the drug administration. IOP values were measured with rebound tonometry (Icare ®, Helsinki, Finland), each animal being positioned in sternal recumbency, without e-collars and with the head maintained relaxed at the level of the thorax. All variables were compared at each specific time point using a repeated-measures analysis of variance (ANOVA) with R® 3.3.3 software and the R-Commander extension. The differences were considered significant when p < 0.05. Results: The study group was composed of 32 dogs with a mean age of 8,6 ± 3,3 years and 5 cats with a mean age of 6,02 ± 5,3 years. Ophthalmic exam was normal. The mean ± SD baseline (T0) and post-treatment (T10, T20) IOP values were respectively: 17,1 ± 3,32 mm Hg, 16,9 ± 3,37 mm Hg and 16,3 ± 3,33 mm Hg. In the majority of the individuals, IOP levels decreased less significantly at T10 comparing to the mean values at T20. There were no statistically significant differences between baseline values and post-treatment values (p=0.296). Conclusions: There were no statistically significant variations in IOP values in dogs and cats after the administration of methadone as a solo-agent of anaesthetic premedication. Methadone may be a good alternative as anaesthetic premedication in intraocular surgery or in sedation of glaucoma patients since it apparently does not interfere with IOP.<br>RESUMO - Objetivo: Este estudo teve como objetivo determinar os efeitos do uso de metadona como fármaco único de pré-medicação cirúrgica, na pressão intraocular, tanto em cães, como em gatos, submetidos a procedimentos cirúrgicos eletivos e/ou exames de diagnóstico complementares que necessitassem de sedação prévia. Métodos: O grupo em estudo incluiu cães e gatos submetidos a sedação. Os valores de pressão intraocular foram medidos antes da administração intravenosa de metadona, na dose de 0,2 mg kg-1, e após 10 minutos (T10) e 20 minutos (T20) da mesma. As medições foram efetuadas por tonometria de ressalto (Icare ®, Helsínquia, Finlândia) com o animal posicionado em decúbito ventral, sem uso de colar isabelino e com a cabeça mantida numa posição relaxada ao nível do tórax. Os valores da variável pressão intraocular, obtidos nos três tempos, foram comparados utilizando o teste de análise de variância (ANOVA) para medidas repetidas, com o auxílio do software R® 3.3.3 software e na sua extensão R-Commander. As diferenças foram consideradas significativas quando p< 0.05. Resultados: O grupo em estudo foi composto por 32 cães e 5 gatos com uma média de idades de 8,6 ± 3,3 e 6,02 ± 5,3 anos de idade, respetivamente. Os valores da média ± desvio padrão da pressão intraocular basais (T0) e após a administração de metadona (T10 e T20) foram, respetivamente: 17,1 ± 3,32 mm Hg, 16,9 ± 3,37 mm Hg e 16,3 ± 3,33 mm Hg. Na maioria dos indivíduos, os níveis de pressão intraocular diminuíram de forma menos marcada em T10 comparativamente com T20. Não se observou diferença estatisticamente significativa entre os três tempos em estudo (p=0,296). Conclusões: Não se observaram variações estatisticamente significativas na pressão intraocular em cães e gatos após a administração de metadona como fármaco único de pré-medicação. Este fármaco pode ser uma boa opção na cirurgia intraocular ou na sedação de animais com diagnóstico prévio de glaucoma, uma vez que aparentemente não interfere com a pressão intraocular.<br>N/A
APA, Harvard, Vancouver, ISO, and other styles
16

MILOSEVIC, RENE. "Pression intra-oculaire : etude biophtalmologique et applications pharmacologiques." Clermont-Ferrand 1, 1994. http://www.theses.fr/1994CLF11003.

Full text
APA, Harvard, Vancouver, ISO, and other styles
17

Renzo, Roberta [UNESP]. "Pressão intra-ocular, condições endoteliais e prostaglandina E2 no humor aquoso de cães com catarata senil madura ou hipermatura." Universidade Estadual Paulista (UNESP), 2012. http://hdl.handle.net/11449/88973.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:23:41Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-02-16Bitstream added on 2014-06-13T20:50:54Z : No. of bitstreams: 1 renzo_r_me_jabo.pdf: 301706 bytes, checksum: 7ba09919044057e80244fe4b39f2b41e (MD5)<br>Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)<br>Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)<br>Estudaram-se a pressão intraocular, a densidade e a hexagonalidade de células endoteliais, níveis de Prostaglandina E2 e sua correlação com catarata senil madura (n=8) ou hipermatura (n=8). Adicionalmente, foram utilizados valores de Prostaglandina E2 do humor aquoso de cães oftalmologicamente saudáveis (n=7). Para avaliação da pressão intraocular empregou-se tonometria digital de aplanação. A avaliação da densidade e da hexagonalidade das células endoteliais foi realizada por meio de microscopia especular de não contato. Sob anestesia geral, 0,2mL de humor aquoso foram colhidos por meio de paracentese da câmara anterior. As amostras de aquoso foram congeladas e armazenadas à -80 oC para mensuração da concentração de PGE2, por imunoensaio enzimático competitivo. Os valores foram comparados estatisticamente, empregando-se análise de variância de via única, e o teste de múltiplas comparações de Bonferroni. Teste t não pareado foi utilizado para se avaliar os dados obtidos por microscopia especular. Possíveis correlações entre os resultados foram comparadas aplicando-se o teste de Person. Adotou-se nível de significância de p<0,05. Em ambos os grupos observou-se diminuição significativa da pressão intraocular (PIO), entretanto não houve diferença entre eles (p = 0,90). As médias dos valores de densidade celular (CD) e de hexagonalidade (HEX) foram 2253,363 cell/mm² e 59,03% para GSM e 2058,325 cell/mm² e 63,75% para GSH, respectivamente. Entretanto não houve diferença significativa entre ambos, tanto para CD (p=0,201), quanto para HEX (p=0,61). Observou-se incremento nos valores de PGE2 nos grupos com catarata em relação aos cães oftalmologicamente saudáveis (p<0,001), entretanto, não houve diferença significativa entre os grupos com catarata...<br>Intraocular pressure, endothelial cell density and hexagonality, and aqueous humor prostaglandin E2 (PGE2) were studied and correlated in dogs with mature (n=8) and hypermature (n=8) senil cataratcs. In addition, aqueous humor PGE2 values of ophthalmic healthy dogs (n=7) were used. Non contact specular microscopy was used to evaluate density and hexagonality of endothelial cells. 0.2mL of aqueous humor was collected by means of anterior chamber paracentesis. Aqueous humor samples were frozen at -80 oC and concentration of PGE2 were quantified by means of competitive enzyme immunoassay. PGE2 values were statistically compared with one way analysis of variance and Bonferroni´s multi comparison test. Specular microscopy data were assessed by means of unparied T test. Person´s test was used in order to assess possible correlations among data. Significance was set at value of P < 0.05. Values of endothelial cell density and hexagonality did not change significantly between groups (P = 0.61). PGE2 values were significantly higher in dogs with cataract, when compared with ophthalmic healthy dogs (P < 0.001), however, this parameter did not change significantly between mature and hypermature groups (P > 0.05). Is it possible tosay that cataract patients in stages of maturity or hipermaturity develop uveitis... (Complete abstract click electronic access below)
APA, Harvard, Vancouver, ISO, and other styles
18

Richer-Dale, Valérie. "Pression intra camérulaire et propriétés de la cornée." Bordeaux 2, 1999. http://www.theses.fr/1999BOR23056.

Full text
APA, Harvard, Vancouver, ISO, and other styles
19

Bacchin, Angela Beatriz de Oliveira. "Curva diária e valores da pressão intraocular obtidos com tonômetro de rebote em equinos hígidos da raça crioula (Equus caballus)." reponame:Biblioteca Digital de Teses e Dissertações da UFRGS, 2018. http://hdl.handle.net/10183/181313.

Full text
Abstract:
A tonometria é de extrema importância durante o exame oftálmico, pois auxilia no diagnóstico e no acompanhamento do glaucoma e de inflamações intraoculares. No entanto, os valores da pressão intraocular podem sofrer influência do momento do dia em que o exame é realizado. Objetivou-se avaliar a pressão intraocular (PIO) com tonômetro de rebote em equinos hígidos da raça Crioula em diferentes horários do dia. Foram avaliados ambos os olhos de 25 cavalos da raça Crioula, machos ou fêmeas, subdivididos em três categorias de diferentes idades designadas por GI: nove animais (3-5 anos de idade), GII: oito animais (6-8 anos de idade) e GIII: oito animais (9-16 anos de idade). Previamente à tonometria foram realizados teste lacrimal de Schirmer, biomicroscopia com lâmpada de fenda, prova da fluoresceína e oftalmoscopia indireta em todos os equinos. Num mesmo dia foram realizadas sete aferições da PIO (às 6, 9, 12, 15, 18, 21 e 24 horas). A avaliação estatística utilizou o teste T de Student quando haviam dois grupos de comparações, e o teste de análise de variância (ANOVA) para as variáveis PIO, horário de aferição (tempo) e categoria de idade. O valor médio da pressão intraocular obtido foi de 28,4±3,7 mmHg considerando todos os animais avaliados. Os valores médios da pressão intraocular para os equinos de GI, GII e GIII foram 29,2±3,5 mmHg, 28,4±4,3 mmHg e 27,7±3,2 mmHg, respectivamente. Não houve diferença estatisticamente significativa entre os olhos direito e esquerdo (p= 0,257), nem entre sexos (p= 0,284). Quando comparadas as idades, a PIO média foi significativamente maior nos indivíduos jovens (p= 0,012). Não houve diferença estatisticamente significativa entre os diferentes horários do dia (p= 0,560). Os valores da PIO aferidos com o tonômetro de rebote em equinos da raça Crioula sofreram influência da idade. Os valores da pressão intraocular média obtidos com tonômetro de rebote em equinos hígidos não variaram em diferentes horários ao longo do dia.<br>The tonometry is extremely important during ophthalmic examination, because assists in the diagnosis and follow-up of glaucoma and intraocular inflammation. However, intraocular pressure values may be influenced by the moment of the day it is measured. The objective was to evaluate the intraocular pressure (IOP) with Rebound Tonometer in healthy horses of the Crioula breed at different times of the day. Twenty five horses, male or female, were divided into three groups by age: Group I: nine horses (3-5 years old), Group II: eight horses (6-8 years old), and Group III: eight horses (9-16 years old). Ophthalmic examination was performed previously by Schirmer Tear Test, slit lamp biomicroscopy, fluorescein test and indirect ophthalmoscopy in all horses. Seven measurements of intraocular pressure were assessed on the same day (at 6, 9, 12, 15, 18, 21 and 24 hours).The Student’s T Test statistical analysis was used when there was two groups of comparisons, and the Analysis of Variance (ANOVA) was used for variables IOP, measurement time and age category. The average value of intraocular pressure was 28.4 ± 3.7 mmHg considering all the animals evaluated. The mean intraocular pressure for groups I, II and III were 29.2 ± 3.5 mmHg, 28.4 ± 4.3 mmHg and 27.7 ± 3.2 mmHg, respectively. There was no statistically significant difference between right and left eyes (p = 0.257), nor between genders (p = 0.284). When compared to the ages, the average IOP was significantly higher in young animals (p = 0.012). There was no statistically significant result between the different times of the day (p = 0.560). The IOP values measured with rebound tonometer in Crioula horses were influenced by age. The average intraocular pressure values obtained with rebound tonometer in healthy horses did not change with time of day.
APA, Harvard, Vancouver, ISO, and other styles
20

Wagatsuma, Juliana Tessália [UNESP]. "Anestesia peribulbar guiada por ultrassom com diferentes volumes de ropivacaína a 1 por cento associada ou não ao bicarbonato de sódio em cães." Universidade Estadual Paulista (UNESP), 2016. http://hdl.handle.net/11449/143898.

Full text
Abstract:
Submitted by JULIANA TESSÁLIA WAGATSUMA null (jutessalia@yahoo.com.br) on 2016-09-16T18:40:05Z No. of bitstreams: 1 tese banco unesp.pdf: 1884895 bytes, checksum: 6191e5a465fbd78f3ca1dd64c9983f46 (MD5)<br>Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-09-16T20:19:27Z (GMT) No. of bitstreams: 1 wagatsuma_jt_dr_araca.pdf: 1884895 bytes, checksum: 6191e5a465fbd78f3ca1dd64c9983f46 (MD5)<br>Made available in DSpace on 2016-09-16T20:19:27Z (GMT). No. of bitstreams: 1 wagatsuma_jt_dr_araca.pdf: 1884895 bytes, checksum: 6191e5a465fbd78f3ca1dd64c9983f46 (MD5) Previous issue date: 2016-08-08<br>Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)<br>Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)<br>Sete cães foram submetidos à anestesia inalatória com isoflurano para permitir a realização do bloqueio peribulbar, com punção única inferior, guiado por ultrassonografia com ropivacaína a 1%, e assim comprovar a eficácia desta técnica de bloqueio guiado na redução do volume anestésico injetado de ropivacaína a 1%, e avaliar possíveis efeitos potencializadores como a redução da latência e do volume anestésico utilizado, assim como complicações oftálmicas associadas à alcalinização do anestésico com bicarbonato de sódio a 0,33%. Foram avaliados dois volumes diferentes de ropivacaína a 1% (0,2 mL/Kg e 0,1 mL/Kg) associados ou não ao bicarbonato de sódio a 0,33% que, ao ser adicionado ao anestésico, elevou o pH da solução anestésica para 6,0. Uma vez realizado o bloqueio peribulbar, com punção única inferior, guiado por ultrassom o tempo necessário para ocorrer a centralização do bulbo do olho era cronometrado, e os animais permaneciam anestesiados para a aferição da pressão intraocular, que foi realizada imediatamente e 15 minutos após o bloqueio e, concluída essa mensuração, a anestesia foi encerrada. Com os cães já despertos foram avaliados os seguintes parâmetros: a pressão intraocular, o diâmetro pupilar, o bloqueio motor, sensitivo (realizado por meio de estesiometria corneal com estesiômetro de Cochet e Bonnet), e a observação das intercorrências oftálmicas como quemose, hiperemia conjuntival, hematoma subconjuntival, prurido e secreção ocular. As análises estatísticas foram conduzidas com o auxílio do software de livre acesso RStudio. Variáveis não paramétricas, ordinais e categóricas foram avaliadas por teste estatística tipo ANOVA ou ATS. Variáveis contínuas paramétricas foram avaliadas pelo Modelo linear misto para medidas repetidas. O Teste Kendall Tau-b foi utilizado para verificar possíveis correlações entre as variáveis. Com exceção do reflexo fotomotor (G0,1: 30 (0-90) e G0,2: 150 (0-210 minutos), não houve diferença significativa entre grupos quando comparado a latência, a pressão intraocular, o diâmetro pupilar, as durações e qualidade dos bloqueios motor e sensitivo, e as intercorrências oftálmicas, mas houve diferença significativa quando comparados os momentos dentro de um mesmo grupo para todas as variáveis analisadas. Deste modo concluiu-se que entre os volumes avaliados de ropivacaína a 1%, no bloqueio peribulbar guiado por US em cães, houve um melhor desempenho clínico relacionado a intensidade e duração dos bloqueios sensitivo e motor, com o volume de 0,2 mL/kg. A adição de NaHCO3 - a 0,33% não agregou benefícios, como a potencialização da ação ou redução da latência anestésica, contudo não ocorreram intercorrências oftálmicas significativas relacionadas diretamente à sua administração ou a da ropivacaína a 1%.<br>Seven dogs were subjected to inhalation anesthesia with isoflurane to allow the realization of peribulbar block, with lower single puncture, guided by ultrasound with 1% ropivacaine, and thus prove the effectiveness of this blocking technique guided in reducing anesthetic volume of ropivacaine 1%, and evaluate possible potentiating effects such as reducing the latency and anesthetic volume used and ophthalmic complications associated with the anesthetic alkalinization with sodium bicarbonate 0,33%. We evaluated two different volumes of 1% ropivacaine (0.2 ml / kg and 0.1 ml / kg) with or without sodium bicarbonate to 0.33% which when added to anesthetic raised the pH of the solution anesthetic to 6.0. Once performed peribulbar block, with lower single puncture guided by ultrasound time required to place the centralization of the eye bulb was timed, and the animals remained anesthetized for the measurement of intraocular pressure was carried out immediately and 15 minutes after blockade and completed this measurement, anesthesia was terminated. With dogs the following parameters already awake were evaluated intraocular pressure, pupil size, the duration and intensity of motor block, sensory (performed by esthesiometry corneal with esthesiometer Cochet and Bonnet), and observation of ophthalmic complications as chemosis, conjunctival hyperemia, subconjunctival hematoma, pruritus, and ocular secretion resulting from the anesthetic technique or employee drug. Statistical analyzes were conducted with the free software Rstudio. nonparametric variables, ordinal variables and categorical variables were evaluated using the statistical test ANOVA type or ATS. Parametric continuous variables were assessed by linear mixed model for repeated measures. The Test Kendall Tau-b was used to verify possible correlations between variables. Aside from fotomotor reflex (G0,1: 30 (0-90) and G0,2: 150 (0-210 minutes), there was no significant difference between groups when compared to latency, intraocular pressure, pupil size, the durations and quality of sensory and motor block, and ophthalmic complications, but there was significant difference when comparing times within the same group for all variables. Thus it was concluded that among the evaluated volumes of 1% ropivacaine in the lock US peribulbar guided in dogs, there was a better clinical performance related to the intensity and duration of sensory and motor block, with a volume of 0.2 ml / kg. the addition of 0.33% NaHCO3 no added benefits, such as potentiation of action or reduction of latency anesthetic, but no significant ophthalmic complications directly related to its administration or the 1% ropivacaine.<br>FAPESP: 2014/09654-6
APA, Harvard, Vancouver, ISO, and other styles
21

Ricci, Cláudia Lizandra. "Uso do tonômetro de aplanação portátil Kowa HA-2 na mensuração da pressão intraocular em gatos." Universidade do Oeste Paulista, 2015. http://bdtd.unoeste.br:8080/tede/handle/tede/314.

Full text
Abstract:
Made available in DSpace on 2016-01-26T18:55:43Z (GMT). No. of bitstreams: 1 Claudia Lizandra Ricci.pdf: 291013 bytes, checksum: b9dccb042e091da74b7d28825ae3639d (MD5) Previous issue date: 2015-03-17<br>The objective of this study was to measurement of the intraocular pressure (IOP) with Kowa HA-2 tonometer in cats analyzing the calibration, the accuracy and the validation of ambulatory clinical use. For calibration the post-mortem study was accomplished in 10 healthy eyes of 5 cats comparing the ocular manometry with the values of the IOP checked with the tonometer. For evaluation of the accuracy an in vivo study was accomplished in 20 healthy eyes of 10 anesthetized cats being compared the ocular manometry with the IOP obtained with the tonometer. For validation of the ambulatory clinical study of the IOP measurement was accomplished in 78 eyes of 39 healthy cats, in 7 eyes with clinical signs of glaucoma and in 20 eyes with clinical signs of uveitis. The correlation coefficient (r²) between the manometer and the tonometer was 0.993 and the equation of lineal regression was y=0.0915x+0.0878 in postmortem study. In the in vivo study the medium values of IOP in the manometry were 15.6±1.1 mmHg and in the tonometry were 15.5±1.2 mmHg, there was no statistics significant difference between the manometry and the tonometry. In the ambulatory clinical study with healthy cats the medium values of IOP with the tonometer were 15.0±1.5 mmHg, in the eyes with clinical signs of glaucoma were 38,4±8,1 mmHg and in the eyes with clinical signs of uveitis were of 10,4±2,0 mmHg. Therefore, there was a satisfactory correlation and accuracy between the IOP values obtained by direct ocular manometry and the tonometer in question. In the ambulatory clinical study the IOP values obtained with the tonometer were compatible for animals with healthy eyes and with clinical signs of glaucoma and uveitis. So, we can conclude that the Kowa HA-2 tonometer can be used in the routine ophthalmic examination, as it is a practical method for IOP measurement in cats.<br>O objetivo deste estudo foi mensurar a pressão intraocular (PIO) com o uso do tonômetro Kowa HA-2 em gatos, analisando a calibração, a acurácia e a validação do seu uso clínico ambulatorial. Para calibração foi realizado o estudo post-mortem em 10 olhos sadios de 5 gatos comparando a manometria ocular com os valores da PIO aferida com o tonômetro. Para avaliação de sua acurácia foi realizado um estudo in vivo em 20 olhos sadios de 10 gatos anestesiados comparando-se a manometria ocular com a PIO obtida com o tonômetro. Para validação do seu uso clínico ambulatorial foi realizado um estudo da mensuração da PIO em 78 olhos sadios de 39 gatos, em 7 olhos com sinais clínicos de glaucoma e em 20 olhos com sinais clínicos de uveíte. O coeficiente de correlação (r²) entre o manômetro e o tonômetro Kowa HA-2 foi de 0,993 e a equação de regressão linear foi y=0,0915x+0,0878 no estudo postmortem. No estudo in vivo, os valores médios de PIO na manometria foram de 15,6±1,1 mmHg e na tonometria foram de 15,5±1,2 mmHg não havendo diferença estatística significativa entre a manometria e a tonometria. No estudo ambulatorial com os gatos sadios, os valores médios de PIO com o tonômetro Kowa HA-2 foram 15,0±1,5 mmHg, nos olhos com sinais clínicos de glaucoma foram 38,4±8,1 mmHg e nos olhos com sinais clínicos de uveíte foram 10,4±2,0 mmHg. Houve, portanto, correlação e acurácia satisfatória entre os valores de PIO com a manometria e o tonômetro em questão. No estudo ambulatorial os valores de PIO obtidos com o tonômetro foram compatíveis para animais com olhos sadios e com sinais clínicos de glaucoma e uveíte. Desta maneira, podemos concluir que o tonômetro Kowa HA-2 pode ser empregado no exame oftálmico de rotina, pois trata-se de um método prático na aferição da PIO em gatos.
APA, Harvard, Vancouver, ISO, and other styles
22

Silva, Renata Maria Monção da. "Avaliação da pressão intraocular, pressão arterial e diâmetro pupilar em coelhos (Oryctolagus cuniculus) submetidos ao bloqueio retrobulbar com diferentes protocolos anestésicos locais." Universidade Federal da Bahia, 2014. http://repositorio.ufba.br/ri/handle/ri/20369.

Full text
Abstract:
Submitted by Emanoel Martins Filho (emanoelfilho@ufba.br) on 2016-09-12T18:02:51Z No. of bitstreams: 1 RenataMoncao.pdf: 3406316 bytes, checksum: d4633de60b23d619f3d881549f59297f (MD5)<br>Approved for entry into archive by Patricia Barroso (pbarroso@ufba.br) on 2016-09-13T20:33:37Z (GMT) No. of bitstreams: 1 RenataMoncao.pdf: 3406316 bytes, checksum: d4633de60b23d619f3d881549f59297f (MD5)<br>Made available in DSpace on 2016-09-13T20:33:37Z (GMT). No. of bitstreams: 1 RenataMoncao.pdf: 3406316 bytes, checksum: d4633de60b23d619f3d881549f59297f (MD5)<br>O objetivo deste estudo foi buscar novos protocolos de anestesia loco regional para procedimentos oftálmicos que proporcionem segurança e manutenção das funções vitais, além de manter a pressão intraocular estável, com centralização do bulbo do olho e acinesia palpebral. Foram utilizados 20 coelhos da raça nova Zelândia para realização de quatro protocolos de anestesia local através do bloqueio retrobulbar com lidocaína 2% com vasoconstritor, lidocaína 2% sem vasoconstritos associada ao tramadol, ropivacaína 1% e bupivacaína 0,5%, cada animal recebeu o volume anestésico de 1ml. Todos os protocolos anestésicos utilizados promoveram acinesia palpebral e centralização do bulbo do olho durante todo o período de avaliação. A realização do bloqueio retrobulbar com os protocolos anestésicos propostos demonstrou ser factível e segura quanto à manutenção da pressão intraocular, pressão arterial invasiva e diâmetro pupilar e pode ser utilizada para realização de cirurgias intraoculares, respeitando-se o tempo de ação de cada anestésico. Todos os anestésicos demonstraram excelente qualidade de bloqueio, porém a bupivacaína foi o anestésico que proporcionou o maior diâmetro pupilar comparativamente aos demais fármacos testados.<br>The aim of this study was to evaluate four protocols of loco regional anesthesia for ophthalmic procedures that could provide safety and life support, in addition to maintain intraocular pressure stable, with eye centralization and eyelid akinesia. 20 New Zealand rabbits were used to perform local anesthesia by retrobulbar block with four protocols: 2% lidocaine with epinephrine, 2% lidocaine without epinephrine associated with tramadol, 1% ropivacaine and bupivacaine 0.5 %. Each animal received an anesthetic volume of 1ml. All anesthetic protocols used promoted eyelid akinesia and centralization of the eye during the assessment period. The retrobulbar block with the proposed anesthetic protocols proved to be feasible and safe for the maintenance of intraocular pressure, invasive blood pressure and pupillary diameter and can be used on intraocular surgeries, respecting the time of action of each anesthetic. All protocols showed an excellent blockage action, but bupivacaine promoted the highest pupil diameter compared to the other drugs tested.
APA, Harvard, Vancouver, ISO, and other styles
23

Borges, Alessandra Gonçalves. "Efeito do cloridrato de dorzolamida a 2%, maleato de timol a 0,5% e associação de ambos na pressão intra-ocular : estudo experimental em cães /." Botucatu : [s.n.], 2004. http://hdl.handle.net/11449/89128.

Full text
Abstract:
Orientador: Cláudia Valéria Seullner Brandão<br>Resumo: Dentre as doenças oculares diagnosticadas no cão, o glaucoma reveste-se de singular importância, como afecção potencial causadora de cegueira. O aumento da pressão intra-ocular (PIO) é o fator de risco primário para o desenvolvimento da neuropatia óptica glaucomatosa canina. A dorzolamida e o timolol, fármacos utilizados para o tratamento do glaucoma, reduzem a PIO pela diminuição da produção do humor aquoso, embora utilizem diferentes mecanismos de ação. O objetivo do trabalho foi avaliar o efeito do cloridrato de dorzolamida 2%, maleato de timolol 0,5% e da combinação de ambos na pressão intra-ocular de cães normais e verificar possíveis alterações na PIO do olho contra-lateral sem tratamento. Foram utilizados 60 cães, distribuídos em três grupos (G) aleatórios de 20 animais. Cada grupo recebeu tratamento tópico no olho esquerdo com timolol 0,5% (GT), dorzolamida 2% (GD) ou a combinação, timolol 0,5% e dorzolamida 2% (GTD). Em todos os grupos, a mensuração da PIO foi realizada utilizando-se tonômetro de aplanação (Tonopen). As medidas foram realizadas, em ambos os olhos, uma hora antes e uma, duas, quatro, seis e oito horas após a instilação de uma gota do colírio no olho esquerdo. No olho tratado percentual de redução máxima da associação timolol/dorzolamida foi numericamente superior (27%) comparado ao timolol (21,9%) e dorzolamida (22,4%) quando utilizados como monoterapia. O olho não tratado apresentou uma redução significativa da PIO, sendo que a redução máxima para o GT foi de 7%, para o GD de 13,8% e para o GTD de 13,6%. A dorzolamida e a associação timolol/dorzolamida promoveram uma ação redutora maior, após uma e seis horas da sua instilação no olho tratado. A administração tópica do timolol 0,5%, dorzolamida a 2% como monoterapia e a associação fixa destes fármacos resultou na redução significativa da PIO de cães clinicamente normais.<br>Abstract: Glaucoma is one of the most important ocular diseases in the dog. Increased intraocular pressure (IOP) is the major risk factor for the development of glaucoma. Dorzolamide and timolol are drugs used for the treatment of glaucoma. Both drugs modify aqueous humor outflow by different mechanisms, resulting in decreased IOP. The aim of this work was to evaluate the efficacy of dorzolamide hydrochloride, timolol maleate and the combination of both drugs on IOP of healthy dogs. Sixty adult dogs were randomly and equally assigned to three groups (n = 20 per group). Each group received topical treatment in the left eye with 0,5% timolol, 2% dorzolamide or the combination (0,5% timolol / 2% dorzolamide). IOP measurements were made using aplanation tonometry (Tono-pen) after local instillation of 0,5% proparacaine in he both eyes. Measurements were performed 1 hour before (baseline) instillation of a single drop of the test drugs in the left eye, and at 1, 2, 4, 6 and 8 hours after treatment. Similar measurements were also performed in the right eye (nontreated eye). In the nontreated eye, IOP decreased over time, with a maximum decrease from baseline of 7%, 13,8% and 13,6% in the timolol, dorzolamide e timolol/dorzolamide groups, respectively. In the treated eye, there was a greater reduction in IOP for the combination (27% maximum decrease from baseline) when compared with timolol (21,9%) and dorzolamide (22,4%) groups. Dorzolamide and timolol/dorzolamide caused greater decreases in IOP at 1 and 6 hours after drug instillation. It was concluded that 0,5% timolol, 2% dorzolamide and the combination of these drugs are effective in reducing IOP in healthy dogs.<br>Mestre
APA, Harvard, Vancouver, ISO, and other styles
24

Ghiggi, Eduardo. "Curva diária de pressão intraocular em porquinhos da índia (Cavia porcellus) de diferentes faixas etárias com tonometria de rebote." reponame:Biblioteca Digital de Teses e Dissertações da UFRGS, 2016. http://hdl.handle.net/10183/147658.

Full text
Abstract:
A aferição da pressão intraocular (PIO) é essencial para o exame oftálmico. Objetivou-se estabelecer os valores da curva diária da PIO de porquinhos da índia de diferentes faixas etárias com tonômetro de rebote. A PIO foi aferida às 6, 12, 18 e 24 horas utilizando o tonômetro de rebote (Tonovet®). Os porquinhos da índia foram subdivididos em dois grupos com 10 animais no grupo I e 4 animais no grupo II, considerando as idades, designados por GI (animais entre 2 a 3 meses de idade) e GII (animais entre 2 a 3 anos de idade). Previamente, foram realizados teste da lágrima de Schirmer, prova da fluoresceína, biomicroscopia com lâmpada de fenda e oftalmoscopia indireta em todos animais. O valor médio da pressão intraocular foi de 12,0 ± 1,83 mmHg. Foram encontradas diferenças significativas entres as idades, sendo que os valores médios para o grupo I foram 11,63 ± 0,29 mmHg, e para o grupo II foram 12,82 ± 0,45mmHg (P= 0,0295). Não foram encontradas diferenças entre ambos os olhos (P= 0,7454). Não foram encontradas diferenças significativas nos valores da PIO relacionadas ao sexo (P= 0,1858). Os valores da PIO em porquinhos da índia tiveram alteração nas horas avaliadas. Com base nos resultados obtidos foi possível concluir que os valores da PIO em porquinhos da índia da sofrem alterações ao longo do dia. Os menores valores de pressão intraocular ocorreram às 18 horas.<br>The measuring of intraocular pressure (IOP) it is essential for the ophthalmic evaluation; the aim of this study was establish the values of the IOP diurnal curve of guinea pigs with different ages using the rebound tonometer (Tonovet®). The animals were divided according to the age in two groups, Group I (GI) constituted with 10 guinea pigs aged between 2 -3 moths, and Group II (GII), 4 animals with 2 -3 years of old. Previously the Schirmer tear test, fluorescein test, biomicroscopy with slit lamp, and direct optalmoscopy were performed on all animals. The men value of IOP was 12.0±0.34 mmHg. Statistical difference were found between ages (mean GI 11.64 ± 0.29 mmHg, and GII 12.83 ± 0.45mmHg), did not have statistical difference related with gender (P= 0.1858) or between eyes (P= 0.7454). In conclusion the guinea pigs had alteration of IOP true the day, the values of IOP are higher in the morning period, decrease true the day and at the night period haves an elevation again.
APA, Harvard, Vancouver, ISO, and other styles
25

Hashimoto, Mitsuo [UNESP]. "Reprodutibilidade da curva de pressão intraocular de 24 horas em pacientes com glaucoma e suspeita de glaucoma." Universidade Estadual Paulista (UNESP), 2015. http://hdl.handle.net/11449/138410.

Full text
Abstract:
Made available in DSpace on 2016-05-17T16:51:11Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-06-10. Added 1 bitstream(s) on 2016-05-17T16:54:44Z : No. of bitstreams: 1 000858467.pdf: 2346803 bytes, checksum: 8eb03d0cf9e13d4b51d80092c6ea5380 (MD5)<br>Foi avaliada a reprodutibilidade das medidas de pressão intraocular (PIO) nos mesmos horários da curva tensional diária (CTD) de 24 horas, com três repetições. Foram estudados 33 indivíduos com glaucoma e suspeita de glaucoma sem tratamento. Todos os participantes foram submetidos a 3 CTDs de 24 horas. Os pacientes foram internados e as medidas foram realizadas às 9:00 hs, 12:00 hs, 15:00 hs, 18:00 hs, 21:00 hs, 24:00 hs e 6:00 hs com tonômetro de aplanação de Goldmann (TAG). A medida das 6:00 hs também foi realizada no leito, utilizando-se um tonômetro manual de Perkins antes da medida com o TAG. Uma segunda CTD de 24 horas foi realizada após um intervalo entre uma e três semanas e uma terceira após mesmo intervalo. A reprodutibilidade foi avaliada em cada horário da CTD de 24 horas com o coeficiente de correlação intraclasse (CCI) e os gráficos de Bland- Altman. Nos gráficos de Bland-Altman considerou-se como limite de concordância uma diferença de até 3 mmHg entre as medidas. O CCI variou de 0,736 a 0,917 nos diferentes horários, estando a maioria deles acima de 0,800. Nos gráficos de Bland- Altman, a porcentagem de pontos dentro do limite de concordância de 3 mmHg variou de 72,7 a 97,0%, sendo na maioria das observações acima de 80%. Concluiuse que as medidas da PIO em cada momento da CTD de 24 horas nas três repetições apresentaram excelente ou boa reprodutibilidade em indivíduos com glaucoma e suspeita de glaucoma<br>The reproducibility of measurements of intraocular pressure (IOP) at the same points of the 24-hour daily tension curve (DTC) with three replications was evaluated. Thirtythree untreated subjects with glaucoma and suspected glaucoma were studied. All participants underwent three 24-hour DTCs. Briefly, participants were hospitalized and IOP measurements obtained at 9:00 AM, noon, 3:00 PM, 6:00 PM, 9:00 PM, midnight and 6:00 AM using a Goldmann applanation tonometer. The 6:00 AM measurement was also obtained at bedside with a handheld Perkins tonometer prior to Goldmann tonometry. A second 24-hour DTC was performed 1 to 3 weeks after the first, and a third and final curve was obtained 1 to 3 weeks after the second. Reproducibility of measurements at each time point of the 24-hour DTC was assessed by means of the intraclass correlation coefficient (ICC) and Bland-Altman plots. A 3-mmHg difference in IOP was defined as the limit of agreement for Bland- Altman plots. ICCs ranged from 0.736 to 0.917 at different time points, with the majority exceeding 0.800. The percentage of points within the 3-mmHg limit of agreement on Bland-Altman plots ranged from 72.7% to 97.0%, exceeding 80% in most cases. In conclusion, in patients with glaucoma or suspected glaucoma, IOP measurements obtained at each time point of the 24-hour DTC showed good or excellent reproducibility across the three curves performed
APA, Harvard, Vancouver, ISO, and other styles
26

Hashimoto, Mitsuo. "Reprodutibilidade da curva de pressão intraocular de 24 horas em pacientes com glaucoma e suspeita de glaucoma /." Botucatu, 2015. http://hdl.handle.net/11449/138410.

Full text
Abstract:
Orientador: Hamilton Almeida Rollo<br>Coorientador: Maria Rosa Bet de Moraes Silva<br>Banca: Edson Nacib Jorge<br>Banca: Ralph Cohen<br>Banca: José Paulo Cabral de Vasconcellos<br>Banca: Maria de Lourdes Veronese Rodrigues<br>Resumo: Foi avaliada a reprodutibilidade das medidas de pressão intraocular (PIO) nos mesmos horários da curva tensional diária (CTD) de 24 horas, com três repetições. Foram estudados 33 indivíduos com glaucoma e suspeita de glaucoma sem tratamento. Todos os participantes foram submetidos a 3 CTDs de 24 horas. Os pacientes foram internados e as medidas foram realizadas às 9:00 hs, 12:00 hs, 15:00 hs, 18:00 hs, 21:00 hs, 24:00 hs e 6:00 hs com tonômetro de aplanação de Goldmann (TAG). A medida das 6:00 hs também foi realizada no leito, utilizando-se um tonômetro manual de Perkins antes da medida com o TAG. Uma segunda CTD de 24 horas foi realizada após um intervalo entre uma e três semanas e uma terceira após mesmo intervalo. A reprodutibilidade foi avaliada em cada horário da CTD de 24 horas com o coeficiente de correlação intraclasse (CCI) e os gráficos de Bland- Altman. Nos gráficos de Bland-Altman considerou-se como limite de concordância uma diferença de até 3 mmHg entre as medidas. O CCI variou de 0,736 a 0,917 nos diferentes horários, estando a maioria deles acima de 0,800. Nos gráficos de Bland- Altman, a porcentagem de pontos dentro do limite de concordância de 3 mmHg variou de 72,7 a 97,0%, sendo na maioria das observações acima de 80%. Concluiuse que as medidas da PIO em cada momento da CTD de 24 horas nas três repetições apresentaram excelente ou boa reprodutibilidade em indivíduos com glaucoma e suspeita de glaucoma<br>Abstract: The reproducibility of measurements of intraocular pressure (IOP) at the same points of the 24-hour daily tension curve (DTC) with three replications was evaluated. Thirtythree untreated subjects with glaucoma and suspected glaucoma were studied. All participants underwent three 24-hour DTCs. Briefly, participants were hospitalized and IOP measurements obtained at 9:00 AM, noon, 3:00 PM, 6:00 PM, 9:00 PM, midnight and 6:00 AM using a Goldmann applanation tonometer. The 6:00 AM measurement was also obtained at bedside with a handheld Perkins tonometer prior to Goldmann tonometry. A second 24-hour DTC was performed 1 to 3 weeks after the first, and a third and final curve was obtained 1 to 3 weeks after the second. Reproducibility of measurements at each time point of the 24-hour DTC was assessed by means of the intraclass correlation coefficient (ICC) and Bland-Altman plots. A 3-mmHg difference in IOP was defined as the limit of agreement for Bland- Altman plots. ICCs ranged from 0.736 to 0.917 at different time points, with the majority exceeding 0.800. The percentage of points within the 3-mmHg limit of agreement on Bland-Altman plots ranged from 72.7% to 97.0%, exceeding 80% in most cases. In conclusion, in patients with glaucoma or suspected glaucoma, IOP measurements obtained at each time point of the 24-hour DTC showed good or excellent reproducibility across the three curves performed<br>Doutor
APA, Harvard, Vancouver, ISO, and other styles
27

Borges, Alessandra Gonçalves [UNESP]. "Efeito do cloridrato de dorzolamida a 2%, maleato de timol a 0,5% e associação de ambos na pressão intra-ocular: estudo experimental em cães." Universidade Estadual Paulista (UNESP), 2004. http://hdl.handle.net/11449/89128.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:23:44Z (GMT). No. of bitstreams: 0 Previous issue date: 2004Bitstream added on 2014-06-13T19:30:13Z : No. of bitstreams: 1 borges_ag_me_botfmvz.pdf: 619936 bytes, checksum: 26f3dbd1632fca5d2ec5d73fee61d030 (MD5)<br>Dentre as doenças oculares diagnosticadas no cão, o glaucoma reveste-se de singular importância, como afecção potencial causadora de cegueira. O aumento da pressão intra-ocular (PIO) é o fator de risco primário para o desenvolvimento da neuropatia óptica glaucomatosa canina. A dorzolamida e o timolol, fármacos utilizados para o tratamento do glaucoma, reduzem a PIO pela diminuição da produção do humor aquoso, embora utilizem diferentes mecanismos de ação. O objetivo do trabalho foi avaliar o efeito do cloridrato de dorzolamida 2%, maleato de timolol 0,5% e da combinação de ambos na pressão intra-ocular de cães normais e verificar possíveis alterações na PIO do olho contra-lateral sem tratamento. Foram utilizados 60 cães, distribuídos em três grupos (G) aleatórios de 20 animais. Cada grupo recebeu tratamento tópico no olho esquerdo com timolol 0,5% (GT), dorzolamida 2% (GD) ou a combinação, timolol 0,5% e dorzolamida 2% (GTD). Em todos os grupos, a mensuração da PIO foi realizada utilizando-se tonômetro de aplanação (Tonopen). As medidas foram realizadas, em ambos os olhos, uma hora antes e uma, duas, quatro, seis e oito horas após a instilação de uma gota do colírio no olho esquerdo. No olho tratado percentual de redução máxima da associação timolol/dorzolamida foi numericamente superior (27%) comparado ao timolol (21,9%) e dorzolamida (22,4%) quando utilizados como monoterapia. O olho não tratado apresentou uma redução significativa da PIO, sendo que a redução máxima para o GT foi de 7%, para o GD de 13,8% e para o GTD de 13,6%. A dorzolamida e a associação timolol/dorzolamida promoveram uma ação redutora maior, após uma e seis horas da sua instilação no olho tratado. A administração tópica do timolol 0,5%, dorzolamida a 2% como monoterapia e a associação fixa destes fármacos resultou na redução significativa da PIO de cães clinicamente normais.<br>Glaucoma is one of the most important ocular diseases in the dog. Increased intraocular pressure (IOP) is the major risk factor for the development of glaucoma. Dorzolamide and timolol are drugs used for the treatment of glaucoma. Both drugs modify aqueous humor outflow by different mechanisms, resulting in decreased IOP. The aim of this work was to evaluate the efficacy of dorzolamide hydrochloride, timolol maleate and the combination of both drugs on IOP of healthy dogs. Sixty adult dogs were randomly and equally assigned to three groups (n = 20 per group). Each group received topical treatment in the left eye with 0,5% timolol, 2% dorzolamide or the combination (0,5% timolol / 2% dorzolamide). IOP measurements were made using aplanation tonometry (Tono-pen) after local instillation of 0,5% proparacaine in he both eyes. Measurements were performed 1 hour before (baseline) instillation of a single drop of the test drugs in the left eye, and at 1, 2, 4, 6 and 8 hours after treatment. Similar measurements were also performed in the right eye (nontreated eye). In the nontreated eye, IOP decreased over time, with a maximum decrease from baseline of 7%, 13,8% and 13,6% in the timolol, dorzolamide e timolol/dorzolamide groups, respectively. In the treated eye, there was a greater reduction in IOP for the combination (27% maximum decrease from baseline) when compared with timolol (21,9%) and dorzolamide (22,4%) groups. Dorzolamide and timolol/dorzolamide caused greater decreases in IOP at 1 and 6 hours after drug instillation. It was concluded that 0,5% timolol, 2% dorzolamide and the combination of these drugs are effective in reducing IOP in healthy dogs.
APA, Harvard, Vancouver, ISO, and other styles
28

Kreuz, André Carvalho. "Eletrorretinograma de padrão reverso macular e multifocal e tomografia de coerência óptica em olhos suspeitos de glaucoma e glaucomatosos com perda de hemicampo." Universidade de São Paulo, 2016. http://www.teses.usp.br/teses/disponiveis/5/5149/tde-06022017-110458/.

Full text
Abstract:
Objetivos: Avaliar a capacidade do eletrorretinograma de padrão reverso (PERG) macular e multifocal (mf) de diferenciar pacientes com suspeita de glaucoma (SG) e glaucoma com defeito de campo hemianópico (GH) de controles, comparar a capacidade de discriminação do PERG e tomografia de coerência óptica (TCO) fourrier domain, e avaliar a relação entre as medidas do PERG e TCO. Métodos: Medidas do campo visual (CV) computadorizado, respostas do PERG transiente e modo estacionário e PERGmf foram obtidos dos SG (n=14, 24 olhos), GH (n=5, 7 olhos) e controles (n=19, 22 olhos). Os seguintes parâmetros de TCO foram investigados: camada de fibras nervosas da retina peripapilar (CFNRpp), espessura total da mácula e espessuras das camadas segmentadas da mácula. As medidas foram analizadas utilizando-se modelos lineares de efeito misto. Também foi avaliada a relação entre as medidas e a performance diagnóstica de cada tecnologia. Resultados: Comparado aos controles, a média do tempo de pico de P50 da resposta do PERG transiente estava reduzida nos SG e GH, enquanto que a fase, a amplitude do modo estacionário e respostas do PERGmf estavam anormais apenas no GH. A média das medidas da TCO de espessura macular e da CFNRpp nos SG e GH diferiram significativamente dos controles. Uma significativa relação foi observada entre o PERG e a maior parte dos dos parâmetros do CV central e TCO. A análise por regressão e componentes principais revelou que a TCO de nervo óptico e mácula, assim como o PERG transiente e PERGmf tiveram estatisticamente capacidade similar em discriminar os SG dos controles. Conclusões: Os parâmetros do PERG e da TCO podem estar anormais, com significativa relação entre as medidas, em uma porcentagem alta de olhos com SG com CV normal. Nossos achados sugerem que as duas tecnologias podem ser úteis e complementares na detecção precoce de glaucoma<br>Purpose: To evaluate the ability of macular and multifocal (mf) pattern electroretinogram (PERG) to differentiate glaucoma suspects (GS) and glaucoma with hemifield loss (GHL) from controls, to compare the discrimination ability of PERG and fourier-domain optical coherence tomography (fdOCT), and to assess the relationship between PERG and fdOCT measurements. Methods: Standard automated perimetry (SAP), steady-state and transient PERG responses and mfPERG measurements were obtained from GS (n=14, 24 eyes), GHL (n=5, 7 eyes) and controls (n=19, 22 eyes). The following fdOCT parameters were investigated: circumpapillary retinal nerve fiber layer (cpRNFL), full-thickness macula, and segmented macular layer thicknesses. Measurements were compared using mixed effects linear models. The relationships between measurements and the diagnostic performance of each technology were also assessed. Results: Compared to controls, average P50 peak time transient PERG responses were reduced in GS and GHL, whereas average phase and amplitude steady-state and mfPERG responses were abnormal only in GHL. The average fdOCT-measured cpRNFL and macular thickness measurements in GS and GHL differed significantly from controls. A significant relationship was found between PERG and most fdOCT or central SAP sensitivity parameters. Principal component regression analysis revealed that optic disc and macular OCT parameters, along with mfPERG and transient PERG parameters had statistically similar ability to discriminate GS from controls. Conclusions: PERG and OCT parameters may be abnormal, with significant correlations between measurements, in a high percentage of GS eyes with normal SAP. Our findings suggest that both technologies may be helpful and complementary in early glaucoma detection
APA, Harvard, Vancouver, ISO, and other styles
29

Lindenmeyer, Rodrigo Leivas. "Pressão intra-ocular em pré-termos de muito baixo peso de nascimento e sua relação com a idade pós-concepção." reponame:Biblioteca Digital de Teses e Dissertações da UFRGS, 2012. http://hdl.handle.net/10183/61888.

Full text
Abstract:
Objetivo: medir a pressão intra-ocular (PIO) em pré-termos de muito baixo peso (PMBP) e correlacionar com a idade pós-concepção (IPC). Métodos: Estudo longitudinal incluindo 50 pré-termos. Local: Hospital de Clínicas de Porto Alegre. Período: entre novembro de 2008 e junho de 2010. Pacientes: PMBP definido como idade nascimento ≤ 1.500 g e idade gestacional ≤ 32 semanas. Intervenção: medidas semanais da PIO. Principais desfechos: variação da PIO de acordo com a idade pós-concepção (IPC definida como a idade gestacional ao nascimento mais a idade no momento do exame) nas semanas seguintes ao nascimento pré-termo. Análise estatística: modelos de efeitos mistos foram utilizados para determinar a variação da PIO em relação a IPC. Foram calculados as médias e os percentis 10 e 90 (P10 e P90) para os valores da PIO. Resultados: Cinqüenta PMBP com idade gestacional média de 29,7 ± 1,6 semanas e peso de nascimento de 1.127,7 ± 222,7 gramas foram avaliados. Não houve diferença significativa entre a PIO do olho direito e do olho esquerdo (p=0.177). A média da PIO em toda a coorte, considerando ambos os olhos, foi de 14,9 ± 4,5 mmHg, sendo que 13,5% das medidas isoladas da PIO foram superiores a 20 mmHg. A PIO reduziu em média 0,29 mmHg para cada aumento de uma semana da IPC (p=0.047 IC95%: -0,58 a -0,0035). A PIO média (P10-P90) reduziu de 16,3 mmHg (10,52-22,16) com 26,3 semanas de IPC para 13,1 mmHg (7,28-18,92) com 37,6 semanas de IPC. Conclusões: A PIO média em PMBP foi 14,9 ± 4,5 mmHg e apresentou correlação negativa em relação a idade pós-concepção.<br>Purpose: To measure intraocular pressure (IOP) in very low birth weight preterm infants and correlate it with the postconceptional age (PCA). Methods: Longitudinal study including 50 premature infants. Setting: Hospital de Clinicas de Porto Alegre, Brazil. Patients: Very low birth weight premature infants (defined as birth weight ≤1,500 g and gestational age ≤32 weeks). Intervention: Weekly measurements of the IOP. Main outcomes: The variation of IOP according to the postconceptional age (PCA defined as the gestational age at birth plus the age in weeks at the time of examination) in the weeks following preterm birth. Statistics: Mixed-effects models were used for the statistical analysis to determine IOP variation according to PCA. Means, 10th and 90th percentiles were calculated for IOP values. Results: Fifty preterm infants with a mean gestational age of 29.7 ± 1.6 weeks and mean birth weight of 1,127.7 ± 222.7 grams were evaluated. Mean IOP in the whole cohort considering both eyes was 14.9 ± 4.5 mmHg, and 13.5% of the IOP measurement values were greater than 20 mmHg. The analysis revealed a mean IOP reduction of 0.29 mmHg for each increase of PCA (p=0.047; 95% CI, -0.58 to -0.0035). Mean IOP (P10- P90) decreased from 16.3 mmHg (10.52-22.16) at 26.3 weeks PCA to 13.1 mmHg (7.28- 18.92) at 37.6 weeks PCA. Conclusions: Mean IOP in very low birth weight preterm infants was 14.9 ± 4.5 mmHg and was negatively correlated with PCA.
APA, Harvard, Vancouver, ISO, and other styles
30

Renzo, Roberta. "Pressão intra-ocular, condições endoteliais e prostaglandina E2 no humor aquoso de cães com catarata senil madura ou hipermatura /." Jaboticabal, 2012. http://hdl.handle.net/11449/88973.

Full text
Abstract:
Orientador: José Luiz Laus<br>Banca: Adriana Morales<br>Banca: Alexandre Lima de Andrade<br>Resumo: Estudaram-se a pressão intraocular, a densidade e a hexagonalidade de células endoteliais, níveis de Prostaglandina E2 e sua correlação com catarata senil madura (n=8) ou hipermatura (n=8). Adicionalmente, foram utilizados valores de Prostaglandina E2 do humor aquoso de cães oftalmologicamente saudáveis (n=7). Para avaliação da pressão intraocular empregou-se tonometria digital de aplanação. A avaliação da densidade e da hexagonalidade das células endoteliais foi realizada por meio de microscopia especular de não contato. Sob anestesia geral, 0,2mL de humor aquoso foram colhidos por meio de paracentese da câmara anterior. As amostras de aquoso foram congeladas e armazenadas à -80 oC para mensuração da concentração de PGE2, por imunoensaio enzimático competitivo. Os valores foram comparados estatisticamente, empregando-se análise de variância de via única, e o teste de múltiplas comparações de Bonferroni. Teste t não pareado foi utilizado para se avaliar os dados obtidos por microscopia especular. Possíveis correlações entre os resultados foram comparadas aplicando-se o teste de Person. Adotou-se nível de significância de p<0,05. Em ambos os grupos observou-se diminuição significativa da pressão intraocular (PIO), entretanto não houve diferença entre eles (p = 0,90). As médias dos valores de densidade celular (CD) e de hexagonalidade (HEX) foram 2253,363 cell/mm² e 59,03% para GSM e 2058,325 cell/mm² e 63,75% para GSH, respectivamente. Entretanto não houve diferença significativa entre ambos, tanto para CD (p=0,201), quanto para HEX (p=0,61). Observou-se incremento nos valores de PGE2 nos grupos com catarata em relação aos cães oftalmologicamente saudáveis (p<0,001), entretanto, não houve diferença significativa entre os grupos com catarata... (Resumo completo, clicar acesso eletrônico abaixo)<br>Abstract: Intraocular pressure, endothelial cell density and hexagonality, and aqueous humor prostaglandin E2 (PGE2) were studied and correlated in dogs with mature (n=8) and hypermature (n=8) senil cataratcs. In addition, aqueous humor PGE2 values of ophthalmic healthy dogs (n=7) were used. Non contact specular microscopy was used to evaluate density and hexagonality of endothelial cells. 0.2mL of aqueous humor was collected by means of anterior chamber paracentesis. Aqueous humor samples were frozen at -80 oC and concentration of PGE2 were quantified by means of competitive enzyme immunoassay. PGE2 values were statistically compared with one way analysis of variance and Bonferroni's multi comparison test. Specular microscopy data were assessed by means of unparied T test. Person's test was used in order to assess possible correlations among data. Significance was set at value of P < 0.05. Values of endothelial cell density and hexagonality did not change significantly between groups (P = 0.61). PGE2 values were significantly higher in dogs with cataract, when compared with ophthalmic healthy dogs (P < 0.001), however, this parameter did not change significantly between mature and hypermature groups (P > 0.05). Is it possible tosay that cataract patients in stages of maturity or hipermaturity develop uveitis... (Complete abstract click electronic access below)<br>Mestre
APA, Harvard, Vancouver, ISO, and other styles
31

Castro, Emerson Fernandes de Sousa e. "Avaliação dos efeitos da variabilidade da pressão arterial sistêmica sobre a pressão de perfusão ocular e suas repercussões sobre o estresse oxidativo em retinas de ratos normotensos e hipertensos." Universidade de São Paulo, 2014. http://www.teses.usp.br/teses/disponiveis/5/5131/tde-01122014-144509/.

Full text
Abstract:
Introdução: A hipertensão arterial sistêmica (HAS) é uma doença que pode determinar lesões em diversos órgãos inclusive nos olhos. As doenças vasculares oculares constituem a grande maioria das causas de cegueira na atualidade e a HAS tem contribuição importante nesta estatística. A variabilidade da pressão arterial tem sido implicada na gênese de uma série de lesões de órgãos-alvo. Na tentativa de compreender melhor a patogênese das doenças vasculares oculares testamos a hipótese de que não apenas os efeitos da HAS, mas também a variabilidade da pressão arterial (PA) poderia determinar lesão de órgão-alvo (ocular). Materiais e Métodos: A desnervação sino-aórtica (DSA), um modelo experimental de aumento da variabilidade da pressão arterial foi utilizado nos experimentos. Foram obtidas medidas da pressão intraocular e a partir destas medidas, a pressão de perfusão ocular. Foram analisados marcadores de estresse oxidativo (8-OHdG e nitrotirosina),VEGF e receptores AT1 na retina de animais normotensos e hipertensos com e sem DSA aguda (12 e 24 horas) e crônica (10 semanas). Resultados: Os animais desnervados apresentaram aumento da variabilidade da PA sem modificar a PA basal e redução da sensibilidade do barorreflexo. Houve aumento da modulação simpática vascular e da pressão de perfusão ocular (PPO), nos animais hipertensos, com aumento adicional da PPO nos hipertensos e desnervados crônicos.Observou-seestresse oxidativo retiniano nos animais desnervados agudos e noshipertensos desnervados crônicos, além do aumento da expressão de receptores AT1 da Angiotensina II nos animais hipertensos. Os níveis de VEGF retinianos dos animais desnervados crônicos, apresentaram comportamento inverso aos níveis de Caspase-3. Conclusão: Tais resultados indicam que só a HAS, mas também a variabilidade da PA podem determinar variações na pressão de perfusão ocular, assim como também podem induzir dano oxidativo às células retinianas. Além disso, pode-se sugerir efeito neuroprotetor retiniano do VEGF<br>Introduction: High blood pressure (HBP) is a disease that can determine lesions in many organs including the eyes. The ocular vascular diseases constitute the vast majority of causes of blindness and hypertension has important contribution in this statistic. Blood pressure variability has been implicated in the genesis of a series of end-organ damage. In an attempt to better understand the pathogenesis of ocular vascular diseases, we hypothesized that not only the effects of hypertension, but also the variability of blood pressure (BPV) could determine target end-organ damage (ocular). Materials and Methods: Sino-aortic denervation (SAD), an experimental model of increased blood pressure variability was used in the experiments. The intraocular pressure measurements were performed and from these measurements the ocular perfusion pressure was estimated. Oxidative stress markers (8-OHdG and nitrotyrosine), VEGF and AT1 receptor in rat retinas were analyzed inacute and chronic hypertensive and normotensiveSAD rats and in controls. Results: Denervated animals showed increased BP variability without altering the basal BP, while presenting reduced baroreflex sensitivity.There was an increase in sympatheticvascular modulation and in OPP,in hypertensive animals, that was additionally in chronic denervated hypertensive animals.Acute denervated and chronic hypertensive denervated animals showed retinal oxidative stress as well as hypertensive animals presented increased expression of AT1 receptors of angiotensin II. The levels of retinal VEGF of chronically denervated animals showed inverse behavior of levels of Caspase-3 Conclusion: These results suggest that, apart from the arterial hypertension, BP variability not only determines changes in ocular perfusion pressure, but also induces oxidative damage to retinal cells. Furthermore, one can suggest retinal neuroprotective effect of VEGF
APA, Harvard, Vancouver, ISO, and other styles
32

Moreno, Tatiana Martinez. "Pressão intraocular média obtida por três diferentes avaliadores utilizando os tonômetros de rebote e de aplanação em equinos." reponame:Biblioteca Digital de Teses e Dissertações da UFRGS, 2016. http://hdl.handle.net/10183/143945.

Full text
Abstract:
A mensuração da pressão intraocular (PIO) é essencial para o exame oftálmico, pois permite o diagnóstico de doenças oftálmicas como uveíte e glaucoma, além de auxiliar no monitoramento das cirurgias intraoculares. Objetivou-se comparar a tonometria de rebote com a tonometria de aplanação em equinos. Além disso, determinar a reprodutibilidade dos valores obtidos em ambos os aparelhos. A PIO foi aferida em 30 equinos da raça Crioula, machos ou fêmeas, com idade entre um e 16 anos utilizando o tonômetro de rebote (TonoVet®) e o tonômetro de aplanação (Tonopen Avia®). Previamente a aferição da PIO, todos os animais foram submetidos ao exame oftálmico incluindo, avaliação dos reflexos pupilares, teste da lágrima de Schirmer, prova da fluoresceína e biomicroscopia com lâmpada de fenda portátil. Foram utilizados apenas bulbos oculares hígidos. A análise estatística foi feita com ANOVA e teste t de Student. A reprodutibilidade foi avaliada pelo cálculo do coeficiente de correlação intraclasse (ICC). A média da PIO foi de 26,16 ± 5,13 mmHg utilizando o tonômetro de rebote e de 22,55 ±7,32 mmHg com o tonômetro de aplanação. A média da PIO de acordo com o avaliador utilizando o tonômetro de rebote foi de 25,27 ± 4,9 mmHg para o examinador A, 25,80 ± 5,2 mmHg para o examinador B e de 27,40 ± 5,1 mmHg para o examinador C. Com o tonômetro de aplanação as médias obtidas foram de 20,03 ± 4,5 mmHg com o examinador A, 19,67 ± 6,0 mmHg com o examinador B e de 27,97 ± 10,3 mmHg com o examinador C (p<2,3). O ICC foi de 0,18 para o tonômetro de aplanação e de 0,41 para o tonômeto de rebote. Os valores da pressão intraocular média obtidos com o tonômetro de rebote são superestimados quando comparados aos valores obtidos com o tonômetro de Tonopen Avia® em equinos saudáveis. Comparativamente ao Tonopen Avia® os valores obtidos com o Tonovet® demonstraram maior reprodutibilidade.<br>The measurement of intraocular pressure (IOP) is essential for the ophthalmic examination, as it allows the diagnosis of eye diseases such as uveitis and glaucoma, as well as aid in the monitoring of intraocular surgery. This study aimed to compare the mean intraocular pressure (IOP) values in horses obtained by three different examiners using the rebound and applanation tonometer’s. Each examiner measured the IOP of 30 “Crioulo” horses, males or females, aged one to 16 years old, using rebound tonometer and applanation tonometer. Previous to the experiment an ophthalmic examination was performed in horses. Only animals without alterations were selected. Three veterinarians measured IOP with rebound (Tonovet®) and applanation tonometer’s (TonoPen Avia®). Comparisons were made using ANOVA and student t test. Intraclass correlation coefficient (ICC) was calculated for reproducibility. IOP measurements resulted in mean values of 26.16 ± 5.13 mmHg for rebound tonometer and 22.55 ±7.32 mmHg for applanation tonometer. These values were different on statistical analysis. Rebound tonometer mean values, according with the examiner, were: A 25.27 ± 4.9 mmHg, B 25.80 ± 5.2, C 27.40 ± 5.1 mmHg. For applanation tonometer the mean IOP for examiner A (20.03 ± 4.5 mmHg), B (19.67 ± 6.0 mmHg), C (27.97 ± 10.3 mmHg). With the Tonopen Avia® tonometer examiner C measured higher IOP’s than examiners A and B. Intraclass correlation coefficient was 0.41 for rebound tonometer was 0.18 for applanation tonometer. It was observed that the values obtained with the Tonovet® were overestimated compared to Tonopen Avia® in healthy horses. When compared with Tonopen Avia® values obtained with the Tonovet® showed a higher reproducibility.
APA, Harvard, Vancouver, ISO, and other styles
33

Andrade, Maria Cristina Caldart de. "Estudo comparativo entre a tonometria de rebote e a tonometria de aplanação em equinos da raça crioula (Equus cabbalus)." reponame:Biblioteca Digital de Teses e Dissertações da UFRGS, 2011. http://hdl.handle.net/10183/49695.

Full text
Abstract:
A aferição da pressão intraocular (PIO) é importante para o diagnóstico e acompanhamento de doenças oculares. Métodos fidedignos para quantificar a PIO de maneira acurada têm sido buscados. Com o aparecimento de tonômetros portáteis, a avaliação da pressão intraocular em equinos tem se intensificado e os diferentes princípios de aferição têm sido comparados. Este estudo objetivou a comparação entre a tonometria de aplanação, realizada com o Tono-Pen Avia®, e tonometria de rebote, realizada com o Tonovet®, em equinos da raça Crioula. Além disso, a utilização, ou não, do cachimbo como método de contenção também foi comparada e submetida à análise estatística. Foram avaliados 30 cavalos com idades entre dois e 20 anos, machos ou fêmeas. Exame oftálmico prévio foi realizado com teste da lágrima de Schirmer, prova da fluoresceína, biomicroscopia com lâmpada de fenda e oftalmoscopia direta. A tonometria de aplanação foi realizada, no mínimo, 30 minutos após a tonometria de rebote. A pressão intraocular média do Tonovet® foi maior, 36,82 ± 5,91mmHg com cachimbo e 30,04 ± 3,19mmHg sem. A do Tono-Pen Avia® foi de 26,43 ± 5,48 mmHg com cachimbo e 23,10 ±4,01mmHg sem. Todos os resultados diferiram estatisticamente entre si. Quando comparados os sexos, o Tono-Pen Avia® não mostrou diferenças, enquanto o Tonovet® mostrou pressões maiores para cavalos castrados e garanhões, e menores para éguas (p<0,001) com a utilização do cachimbo. Não há correlação entre a idade dos cavalos e os valores de PIO, independente do aparelho (p > 0,05). Os valores da PIO com o Tonovet® foram maiores do que os obtidos com o Tono-Pen Avia®. A contenção dos animais com cachimbo eleva a pressão intraocular em equinos.<br>Intraocular pressure evaluation is important for diagnosis and control of ophthalmic diseases. Accurate methods to quantify intraocular pressure have been searched. With the development of handheld tonometers, equine intraocular pressure evaluation has been intensified and the different principles of measurement have been compared. The objective of this study was to compare the applanation tonometry, taken with the Tono- Pen Avia® and the rebound tonometry, taken with the Tonovet® in adult “crioulo” breed horses. The age, gender and the use of upper lip twitch as a restraint method was also surveyed and submitted to statistical analysis. Thirty horses, aged two to 20, male or female were evaluated. A previous ophthalmic examination was performed with Schirmer tear test, fluoresceine test, slit lamp biomicroscopy and direct ophthalmoscopy in all animals. Applanation tonometry was performed, at least, 30 minutes after rebound tonometry. Intraocular pressure mean values measured with the Tonovet® was higher, 36,82±5,91mmHg with the lip twitch and 30,04±3,19mmHg without. Tonopen Avia® mean values were 26,43±5,48mmHg with the lip twitch and 23,10±4,1mmHg without. All results was statistical different between themselves. When genders were compared the Tono-Pen Avia® revealed no difference, however the Tonovet® showed higher pressures for male horses (p‹0,001) with the use of lip twitch. There was no correlation between age and intraocular pressure in “crioulo” horses, regardless of the equipment tested (p›0,05). Intraocular pressure mean values measured with the Tonove®t were higher than those obtained with the Tono-Pen Avia®. The restraint of animals with upper lip twitch increases equine intraocular pressure.
APA, Harvard, Vancouver, ISO, and other styles
34

Pisa, Ana Rita da Costa. "Tonometria em aves de rapina : aspectos da sua aplicação na prática clínica." Master's thesis, Universidade Técnica de Lisboa. Faculdade de Medicina Veterinária, 2011. http://hdl.handle.net/10400.5/3604.

Full text
Abstract:
Dissertação de Mestrado Integrado em Medicina Veterinária<br>Uma apreciação correcta e atempada da pressão intraocular (PIO) é crítica para a avaliação de alterações oculares como o glaucoma e uveíte. Na prática clínica esta é realizada recorrendo à sua medição indirecta através da tonometria. No entanto, para que esta tenha valor diagnóstico, o clínico necessita conhecer os valores normais de PIO das espécies examinadas. Neste estudo foi realizada a tonometria de aplanamento com recurso ao Tono-Pen VET® (Reichert Technologies, 230635V, Nova Iorque, E.U.A.), para estimar a PIO em 40 Peneireiros das torres (Falco naumanni) e 12 Peneireiros comuns (Falco tinnunculus), animais residentes no Grupo de Rehabilitación de la Fauna Autóctona y su Hábitat (GREFA) em Madrid, Espanha. Antes da tonometria foi realizado um exame físico e oftalmológico completo a todas as aves, garantindo o seu estado hígido para integração neste estudo. As medições tonométricas foram realizadas após a aplicação de uma gota de anestésico tópico (hidrocloreto de oxibuprocaína e hidrocleto de tetracaína, Colircusi Anestesico Doble®, Laboratórios Alcon, Barcelona, Espanha) na superfície corneana dos animais. A média (± DP) de PIO no Peneireiro das torres foi de 11,4 ± 2,7 mmHg (68 olhos) e de 13,9 ± 3,5 mmHg (22 olhos) no Peneireiro comum. Não se encontraram efeitos significativos na mesma entre sexos, idades, olho direito e esquerdo e o número da medição para ambas as espécies. Foram encontradas diferenças significativas entre espécies (teste de duas amostras de Wilcoxon, P=0,017). Alguns aspectos inerentes à técnica tonométrica foram ainda avaliados, em relação aos quais, se verificou que a temperatura do ambiente em que se efectuaram as medições tonométricas tinha efeito na PIO, o qual foi significativo (teste de duas amostras de Wilcoxon, P=0,047). Sugere-se ainda, que a realização de medições pode beneficiar da crescente experiência do utilizador no manuseamento do tonómetro. Em geral, a tonometria de aplanamento demonstrou ser um método diagnóstico da PIO com aplicabilidade e facilidade de utilização bem como, apresentou um boa aceitação por parte das aves de rapina abordadas. No entanto, ao não existir um instrumento ideal para cada animal, é uma técnica que deve considerar a variabilidade existente entre espécies, indivíduos e utilizadores.<br>ABSTRACT - TONOMETRY IN BIRDS OF PREY – ASPECTS OF ITS APPLICATION IN THE CLINICAL PRACTICE - An accurate and early assessment of intraocular pressure (IOP) is essential for evaluating ocular disorders such as glaucoma and uveitis. In the clinical practice this is accomplished by its indirect measure through tonometry. Nevertheless, for it to be of diagnostic value the clinician must know the normal values of the examined species. In this study applanation tonometry was performed using the Tono-Pen VET® (Reichert Technologies, 230635V, New York, U.S.A.), to estimate IOP in 40 Lesser kestrels (Falco naumanni) and 12 Common kestrels (Falco tinnunculus), resident animals of the Grupo de Rehabilitación de la Fauna Autóctona y su Hábitat (GREFA), in Madrid, Spain. Before the tonometry, a complete physical and ophthalmological examination was carried out in all birds ensuring their healthy state for inclusion in this study. Tonometric measurements were performed after application of one drop of topical anesthetic (oxybuprocaine hydrochloride and tetracaine hydrochloride, Colircusi Anestesico Doble®, Alcon Laboratories, Barcelona, Spain) on the animals’ corneal surface. Mean (± SD) IOP in the Lesser kestrel was 11,4 ± 2,7 mmHg (68 eyes) and 13,9 ± 3,5 mmHg (22 eyes) in the Common kestrel. There were no significant effects between sex, age, right and left eye or reading number on the IOP measured in any of the species. Significant differences were found between species (Two-sample Wilcoxon, P=0,017). Some inherent aspects to the tonometry technique were also evaluated, for which it was found that the environment temperature in which the measurements took place had a significant effect on the IOP (Two-sample Wilcoxon, P=0,047). It is also suggested that the performance of measurements can benefit from the growing user experience in handling the tonometer. In general, applanation tonometry has proven to be an IOP diagnostic method with great application, easy use and showing a good acceptance by the bird of prey patient. However, since there isn’t an ideal instrument for each animal, it is a technique that must consider the variability among species, individuals and users.
APA, Harvard, Vancouver, ISO, and other styles
35

Valbon, Bruno de Freitas. "Estudo sobre a deformação da córnea utilizando o sistema de tonometria de não contato integrado a uma câmera de Scheimpflug em olhos saudáveis." Universidade de São Paulo, 2016. http://www.teses.usp.br/teses/disponiveis/5/5149/tde-05122016-150521/.

Full text
Abstract:
OBJETIVOS: 1) Avaliar os parâmetros de biomecânica ocular provenientes do Corvis ST (Oculus Corvis ST, Scheimpflug Technology; Wetzlar, Germany) obtidos de olhos saudáveis de uma população de pacientes brasileiros. 2) Correlacionar os parâmetros derivados do Corvis ST com a idade de pacientes jovens saudáveis. 3) Verificar se as técnicas de facoemulsificação (FC) e do laser de femtosegundo (LFS), empregadas na correção cirúrgica de catatara, influenciam os parâmetros de biomecânica ocular provenientes do Corvis ST. 4) Analisar as alterações da deformação da córnea observadas em um caso de ectasia pós LASIK com flap espesso. MÉTODOS: 1) Estudo clínico transversal conduzido em 90 pacientes (90 olhos saudáveis). Foram avaliados 11 parâmetros derivados do sistema de tonometria de não contato integrado com a câmera ultrarrápida de Scheimpflug (Oculus Corvis ST, Scheimpflug Technology; Wetzlar, Germany), a saber: deformidade de amplitude (DA); pressão intraocular; 1st A time; tempo de concavidade máxima; 2nd A time; 1st A Length (tempo da primeira aplanação); 2nd A Length (tempo da segunda aplanação); raio de curvatura de maior alcance; raio de curvatura normal; velocidade de entrada (Vin) e de saída (Vout). Estes parâmetros foram correlacionados com a espessura central corneana mensurada pela Tomografia de Córnea e Segmento Anterior (Pentacam® - Oculus, Wetzlar, Germany). 2) Estudo clínico observacional, retrospectivo, conduzido em 89 pacientes (89 olhos saudáveis). Os parâmetros derivados do Corvis ST foram correlacionados com a idade dos pacientes. 3) Estudo clínico prospectivo, envolvendo 151 olhos de 127 pacientes com diagnóstico de catarata nuclear. Setenta e cinco olhos de 65 pacientes foram submetidos à técnica do laser de femtosegundo (AlconLenSx, Aliso Viejo, USA) e 76 olhos de 62 pacientes à facoemulsificação convencional (Alcon Infinit, Fort Worth, USA). Foram avaliados os 11 parâmetros de biomecânica ocular derivados do Corvis ST antes (Pré) e após as cirurgias de catarata (D1, primeiro dia de pósoperatório). A densitometria do cristalino (scattering) foi realizada pelo PNS (Pentacam Nucleus Staging). 4) Avaliação com tomografia de coerência óptica de espessura dos flaps corneanos pós Lasik e análise dos parâmetros biomecânicos provenientes do Corvis ST em uma córnea com ectasia pós Lasik. RESULTADOS: 1) A média de idade dos pacientes foi de 35,80 ± 12,83 anos. A média do equivalente esférico foi de -3,29 ± 3,69 dioptrias. A média da espessura central corneana foi de 547,50 ± 32,00 ?m Os valores dos 11 parâmetros biomecânicos obtidos de olhos saudáveis, foram os seguintes: deformidade de amplitude 1,05 ± 0,08 mm; tempo de concavidade máxima 18,38 ± 0,93 ms; pressão intraocular 16,43 ± 2,15 mmHg; tempo da primeira aplanação (1st A time) 8,32 ± 0,33 ms; tempo da segunda aplanação 23,80 ± 0,44 ms; raio de curvatura de maior alcance 11,09 ± 2,06 mm; raio de curvatura normal 7,59 ± 0,67 mm; tempo da primeira aplanação (1st A Length) 2,07 ± 0,38 mm; tempo da segunda aplanação (2nd A Length) 2,37 ± 0,47 mm; velocidade de entrada (Vin) 0,21 ± 0,05 m/s e velocidade de saída (Vout) -0,33 ± 0,07 m/s. 2) A média de idade dos pacientes foi de 27,50 ± 6,30 anos. O tempo de concavidade máxima alcançada da córnea (HC-time) foi o único dos 11 parâmetros que apresentou correlação significativa com a idade (p=0,04, rs=0,18). 3) A média de idade dos pacientes dos grupos LFS (laser de femtosegundo) e FC (facoemulsificação convencional) foram, respectivamente, 67,6 ± 9,9 anos e 68,4 ± 11,8 anos. No grupo LFS, 9 dos 11 parâmetros foram estatisticamente significativos entre o Pré e D1; e no grupo FC, 7 dos 11 parâmetros foram estatisticamente significativos entre o Pré e D1. Entre os 11 parâmetros biomecânicos avaliados, somente o tempo de concavidade máxima da córnea (HC-time) foi significativamente diferente entre os dois grupos em D1 (p=0,0387). 4) Paciente do sexo feminino, 45 anos, submetida à Lasik em ambos os olhos. Com a utilização da tomografia de coerência óptica (OCT Rtvue, OptoVue, Fremont, CA,USA) foram identificados: um flap com espessura central de 392 ?m no OD e dois cortes, sendo um flap incompleto profundo e o outro mais fino superiormente, no OE. Os parâmetros derivados do Corvis ST como a deformidade de amplitude são diferentes em ambos os olhos. CONCLUSÕES: 1) Os valores de 8 dos 11 parâmetros derivados do Corvis ST foram influenciados pela espessura central da córnea, porém esta influência foi baixa. 2) Em olhos saudáveis de pacientes jovens foi obtida correlação significativa entre a idade e o tempo de concavidade máxima, que é o tempo do início de aplanação até a concavidade máxima alcançada da córnea. 3) O laser de femtosegundo para cirurgia de catarata e a técnica de facoemulsificação convencional induziram alterações nas propriedades biomecânicas da córnea no D1. Dos 11 parâmetros biomecânicos estudados apenas o tempo de concavidade máxima da córnea apresentou diferença significativa entre os grupos (LFS e FC) no D1. 4) A ectasia unilateral após LASIK pode ocorrer devido a flap espesso com falência biomecânica da córnea<br>PURPOSE: 1) To evaluate ocular biomechanical metrics given by the CorVis ST (Oculus, Inc., Berlin, Germany) in a population of healthy Brazilian patients. 2) To correlate parameters derived from corneal deformation resulting from non-contact tonometry integrated with an ultra-high-speed (UHS) Scheimpflug camera (Oculus Corvis ST, Scheimpflug Technology; Wetzlar, Germany) with age in normal eyes from young patients. 3) To evaluate the changes of corneal biomechanical after femtosecond laser - assisted cataract (FS) and to compare the parameters derived by Corvis ST between standard phacoemulsification (SP) and femtosecond laser - assisted in cataract surgery. 4) To report a case of post-LASIK corneal ectasia due to a thick flap, while the contralateral eye did not develop ectasia after an incomplete deep flap cut, followed by a thinner flap Lasik procedure. METHODS: 1) An observational and cross-sectional study involving 1 eye randomly selected from 90 healthy patients. Studied parameters (including deformation amplitude, first applanation time, highest concavity time, second applanation time, first applanation length, second applanation length, curvature radius highest concavity, curvature radius normal, velocity in, and velocity out) derived from the CorVis ST were correlated to central corneal thickness from the Pentacam (Oculus, Inc.). Differences between data on the basis of gender were evaluated. 2) Observational, retrospective study involving one eye randomly selected from study participants, totaling 89 healthy eyes. The Scheimpflug images were taken with an ultra-high-speed camera during each measurement by the Corvis ST. The deformation amplitude (DA) and other parameters (e.g., pachy apex, intraocular pressure, 1st A time, highest concavity-time, 2nd A time, 1st A Length, 2nd A Length, Wing-Dist, curvature radius highest concavity, curvature radius normal, Vin, Vout) measured by the corvis ST were correlated with age. 3) Prospective study: 151 eyes of 127 patients were underwent cataract surgery. 75 eyes of 65 patients were with femtosecond laser-assisted (FS)(Alcon Len Sx, Aliso Viejo,USA) and 76 eyes of 62 patients with standard phacoemulsification (SP) (Alcon Infinit, FortWorth, USA). 4) Case Report. RESULTS: 1) About the first study: Mean patient age was 35.80 ± 12.83 years (range: 21.07 to 78.84 years). Mean central corneal thickness was 547.50 ± 32.00 ?m (range: 490 to 647 ?m) and mean spherical equivalent refraction was -3.29 ± 3.69 diopters (range: -9.50 to +10.37 diopters). Mean deformation amplitude was 1.05 ± 0.08 mm (range: 0.91 to 1.26 mm). Highest concavity time was 18.38 ± 0.93 ms (range: 16.95 to 21.07 ms). Intraocular pressure was 16.43 ± 2.15 mm Hg (range: 11.50 to 21.0 mm Hg). First applanation time was 8.32 ± 0.33 ms (range: 7.53 to 9.12 ms) and second applanation time was 23.80 ± 0.44 ms (range: 22.76 to 24.95 ms). First applanation length (max) was 2.07 ± 0.38 mm (range: 1.20 to 3.10 mm) and second applanation length (max) was 2.37 ± 0.47 mm (range: 1.33 to 4.12 mm). Curvature radius highest concavity was 11.09 ± 2.06 mm (range: 7.58 to 15.98 mm) and curvature radius normal was 7.59 ± 0.67 mm (range: 6.82 to 11.02 mm). Velocity in was 0.21 ± 0.05 m/s (range: 0.16 to 0.72 m/s) and velocity out was -0.33 ± 0.07 m/s (range: - 0.72 to -0.20 m/s). Studied parameters were not associated with gender. 2) Mean patient age was 27.50 ± 6.30 years. The highest concavity-time was the only studied parameter statistically significantly correlated to age (i.e., p=0.04, rs=0.18). 3) In relation the surgery of cataract: In group of FS, 9 of 11 parameters derived from Corvis ST were statistically significant (ss). In group of SP, 7 of 11 parameters derived from Corvis ST were ss. Only the HC - time was statistically significant between two groups (FS;SP) with p = 0.0387. 4) Corneal OCT identified a deep meniscos-shaped Lasik flap, with a central thickness of a 392 ?m in the right eye, and a incomplete deep peripheral cut in the left eye with a thinner meniscos-shaped LASIK flap. CONCLUSIONS: 1) Eight of 11 ocular biomechanical metrics given by the CorVis ST were associated with central corneal thickness, but the influence of central corneal thickness on these measurements was low. 2) In healthy eyes, age and pressure or biomechanics as derived from the Corvis ST parameters were not associated with exception to highestconcavity-time, i.e., the time from starting until the highest concavity is reached. 3) The use of the femtosecond laser- assisted system for cataract surgery and standard phacoemulsification induzed changes of biomechanical properties of the cornea by Corvis ST. Only 1 of 11 parameters studied was different statistically in two groups. 4) Unilateral ectasia after LASIK may occur due to a thick flap which leads to biomechanical failure of the cornea
APA, Harvard, Vancouver, ISO, and other styles
36

Le, Gac-Verdier Laurence. "Etude de la microcirculation et de la macrocirculation dans le glaucome à pression intraoculaire normalisée." Bordeaux 2, 1994. http://www.theses.fr/1994BOR23056.

Full text
APA, Harvard, Vancouver, ISO, and other styles
37

Massa, Resende Graziela 1980. "Central corneal thickness and intraocular pressure in children undergoing congenital cataract surgery = a prospective, longitudinal study = Estudo longitudinal da paquimetria corneana central e da pressão intraocular de crianças submetidas à extração de catarata congênita." [s.n.], 2013. http://repositorio.unicamp.br/jspui/handle/REPOSIP/309868.

Full text
Abstract:
Orientadores: Vital Paulino Costa, Carlos Eduardo Leite Arieta<br>Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas<br>Made available in DSpace on 2018-08-23T19:38:14Z (GMT). No. of bitstreams: 1 MassaResende_Graziela_D.pdf: 3242400 bytes, checksum: e2f62de85f9ba384fc976b9263cd9197 (MD5) Previous issue date: 2013<br>Resumo: O presente estudo tem como objetivos investigar a variação da espessura corneana central (ECC) e da pressão intraocular (PIO) em crianças após cirurgia de catarata congênita, bem como fatores de risco associados com essas mudanças. Vinte e seis crianças com catarata congênita foram recrutadas prospectivamente antes da cirurgia para remoção da mesma. Trinta e sete olhos foram analisados. Todos pacientes foram submetidos a exame oftalmológico completo com avaliação da PIO e da ECC antes da cirurgia e 6, 12, 18, 24 e 36 meses após o procedimento cirúrgico, pelo mesmo observador. A paquimetria ultrassônica foi realizada com o aparelho Ocuscan RXP (Alcon Laboratories Inc, USA), e a tonometria foi realizada com o tonômetro de aplanação de Goldmann modelo R900 (Haag-Streit, Koeniz, Suíça) ou tonômetro de aplanação de Perkins (Clement Clark International ltd, Londres, Inglaterra). Dos 37 olhos, 15 tornaram-se afácicos e 22, pseudofácicos. A ECC média aumentou significativamente de 556,24 ± 44,19 ?m para 585,07 ± 56,45 ?m (p = 0,025) ao final de três anos, enquanto a PIO média aumentou significativamente de 12,05 ± 2,3 mmHg para 13,96 ± 2,99 mmHg (p = 0,005). Olhos afácicos foram submetidos à cirurgia em uma idade mais precoce (15,16 ± 32,02 meses) em comparação aos olhos pseudofácicos (71,48 ± 53,14 meses) (p <0,001). Após três anos, a média de variação da ECC, nos olhos afácicos (56,10 ± 46,97 ?m), foi significativamente maior que nos olhos pseudofácicos (12,71 ± 38,41 ?m) (p = 0,015). Encontramos correlação negativa entre a idade no momento da cirurgia e a variação da ECC (r = -0,34, p = 0,04), mas não entre idade e variação da PIO (r = -0,18, p = 0,27). Quando a cirurgia foi realizada entre 0 e 1 ano de idade, a média de variação da ECC, em três anos, foi de 69,0 ± 40,3 ?m, em comparação com 1,0 ± 23,17, -20,0 ± 8,04 e 34,25 ± 40,11 ?m quando as cirurgias foram realizadas de 1 a 5, 5 a 10 e > 10 anos, respectivamente (p <0,001). Não houve correlação da variação da PIO com a variação da ECC (r = 0,31, p = 0,06). Concluímos que a ECC aumenta nos olhos submetidos à cirurgia de catarata congênita, especialmente quando a cirurgia é realizada em uma idade precoce<br>Abstract: The present study aims to investigate the variation of central corneal thickness (CCT) and intraocular pressure (IOP) in children after congenital cataract surgery, as well as risk factors associated with these changes. Twenty-six children with congenital cataract were prospectively recruited prior to surgery. Thirty-seven eyes were analyzed. All patients underwent a complete ophthalmic examination with assessment of IOP and CCT before surgery and 6, 12, 18, 24 and 36 months after surgery by the same observer. Ultrasonic pachymetry was performed with the handset unit Ocuscan RXP (Alcon Laboratories Inc, USA) and tonometry was performed with the Goldmann applanation tonometer model R900 (Haag-Streit, Koeniz, Switzerland) or the Perkins applanation tonometer (Clement Clark International Ltd, London, England). Among the 37 eyes, 15 became aphakic and 22 pseudophakic. The mean CCT increased significantly from 556.24 ± 44.19 ?m to 585.07 ± 56.45 ?m (p = 0.025) at the end of three years, while the mean IOP increased significantly from 12.05 ± 2.3 mmHg to 13, 96 mmHg ± 2.99 (p = 0.005). Aphakic eyes underwent surgery at an earlier age (15.16 ± 32.02 months) compared with pseudophakic eyes (71.48 ± 53.14 months) (p <0.001). After three years, the mean CCT change in aphakic eyes (56.10 ± 46.97 ?m) was significantly higher than in pseudophakic eyes (12.71 ± 38.41 ?m) (p = 0.015). Age at the time of surgery was inversely correlated to CCT change (r = -0.34, p= 0.04), but not to IOP change (r=-0.18, p= 0.27). When surgery was performed between 0 and 1 year of age, the mean CCT change in 3 years was 69.0 ± 40.03 ?m, compared with 1.0 ± 23.17, -20.0 ± 6.56 and 34.25 ± 40.11 ?m when the surgeries were performed between 1-5, 5-10 and > 10 years, respectively (p <0.001). There was no correlation between IOP change and CCT change (r = 0.31, p = 0.06). We conclude that CCT increases in eyes undergoing congenital cataract surgery, especially when the surgery is performed at an early age<br>Doutorado<br>Oftalmologia<br>Doutora em Ciências Médicas
APA, Harvard, Vancouver, ISO, and other styles
38

Kennel, Nathalie. "Analyse comparative de deux tonomètres à air pulsé (X PERT NCT, TOP CON CT 20) au tonomètre de Goldmann." Université Louis Pasteur (Strasbourg) (1971-2008), 1992. http://www.theses.fr/1992STR1M195.

Full text
APA, Harvard, Vancouver, ISO, and other styles
39

Suzuki, Ricardo. "Estudo da eficácia do agulhamento transconjuntival com 5-fluoracil em olhos com pressão intraocular elevada e bolha encapsulada pós trabeculectomia." Universidade de São Paulo, 2014. http://www.teses.usp.br/teses/disponiveis/5/5149/tde-26052014-101756/.

Full text
Abstract:
Objetivo: Estudo comparativo da pressão intraocular (PIO) após agulhamento transconjuntival (ATC) com 5-fluoracil (5-FU) e tratamento clínico (TC) em olhos glaucomatosos com bolha encapsulada e PIO não controlada após trabeculectomia com mitomicina C (MMC), no final de 12 meses de seguimento. Desenho: Estudo prospectivo, randomizado, intervencionista. Participantes: 40 olhos de 39 pacientes com bolha encapsulada, desenvolvida em 5 meses ou menos, após trabeculectomia primária com mitomicina e PIO >= 20mmHg. Métodos: Os olhos foram randomizados para ATC com 5-FU e TC. Um máximo de dois ATC foi permitido no estudo. Todos os olhos foram acompanhados por 12 meses. O sucesso foi definido como PIO <= 18 mmHg e redução de 20% da PIO basal (sem medicações no grupo ATC). Resultados: A média da PIO em 12 meses de acompanhamento foi de 12,14 ± 2,80 mmHg no grupo do ATC e 15,13 ± 2,07 mmHg no grupo do TC (p = 0,004). 14 olhos (70%) foram considerados sucesso no grupo do ATC e 15 olhos (75%) no grupo do TC (p = 0,89). O número médio de agulhamentos foi de 1,35 ± 0,49 e a quantidade média de medicamentos foi de 2,15 ± 0,74. Conclusões: Houve uma taxa de sucesso semelhante nos olhos randomizados para ATC com 5-FU em comparação com TC em 12 meses de seguimento. No entanto, foi observada uma significativa menor média da PIO, após o ATC<br>Objective: To compare de efficacy of transconjuctival needling revision (TNR) with 5-fluorouracil (5-FU) and medical treatment (MT) in glaucomatous eyes with encapsulated bleb and uncontrolled intraocular pressure (IOP) after trabeculectomy with mitomycin C (MMC) at 12 months follow-up. Design: Prospective, randomized, interventional study. Participants: Forty eyes of 39 patients with encapsulated bleb developed in 5 months or less following primary trabeculectomy with mitomycin and IOP >= 20mmHg. Methods: Eyes were randomized to either TNR with 5-FU or MT. A maximum of two TNR was allowed in the study. All eyes were followed-up for 12 months. Success of treatment was defined as IOP <= 18mmHg and a 20% reduction from baseline (no medications in TNR group). Results: Mean IOP at 12 months follow-up was 12.14 ± 2.80 mmHg in the TNR group and 15.13 ± 2.07 mmHg in the MT group (p=0.004). Fourteen eyes (70%) were considered a success in the TNR group and 15 eyes (75%) in the MT group (p=0.89). The number of needling procedure was 1.35 ± 0.49 procedures and the number of medication was 2.15 ± 0.74 medications. Conclusions: We have demonstrated a similar success rates in eyes randomized to MT in comparison to TNR with 5-FU at the last follow-up. However, a significant lower mean IOP after TNR was observed
APA, Harvard, Vancouver, ISO, and other styles
40

Mendes, Marcio Henrique. "Comparação dos valores da pressão intraocular obtidos com diferentes tonômetros e suas correlações com dados biométricos oculares no glaucoma congênito." Universidade de São Paulo, 2013. http://www.teses.usp.br/teses/disponiveis/5/5149/tde-16012014-154728/.

Full text
Abstract:
OBJETIVOS: Comparar os valores da pressão intraocular (PIO), obtidos por intermédio do tonômetro de Perkins (TPK), tonômetro de contorno dinâmico Pascal (TCD) e Tono-Pen (TNP), confrontando-os com o tonômetro de aplanação de Goldmann (TAG), e correlacionar seus valores tonométricos com parâmetros biométricos oculares em pacientes portadores de glaucoma congênito primário. MÉTODOS: Estudo prospectivo, transversal, com inclusão de 46 pacientes (46 olhos) com diagnóstico de glaucoma congênito primário, com idades entre 12 e 40 anos, após obtenção do Termo de Consentimento Livre e Esclarecido. Todos os olhos estudados foram submetidos à tonometria ocular usando os tonômetros de Goldmann, de Perkins, o Tono-Pen e o tonômetro de contorno dinâmico Pascal. A ordem das tonometrias foi aleatória e o tonômetro de Goldmann foi adotado como padrão ouro. Os parâmetros biométricos estudados foram a curvatura (medida pela ceratometria), a espessura central da córnea (paquimetria), o diâmetro corneal (medido por meio de compasso cirúrgico) e o comprimento axial do olho foi obtido pela biometria ultrassônica. As distribuições dos parâmetros biométricos, assim como das tonometrias foram plotadas e analisadas conforme teste de Kolmogorov-Smirnov para aceitação de normalidade. O teste t de Student pareado para amostras independentes foi empregado para comparar as médias tonométricas de cada tonômetro com o padrão ouro. As correlações entre os parâmetros biométricos e as tonometrias foram realizadas através do coeficiente de correlação de Pearson e gráficos de regressão linear. O mesmo procedimento foi feito entre os parâmetros biométricos e as diferenças entre as três distintas tonometrias e a TAG. A concordância entre os tonômetros Perkins, Pascal e Tono-Pen e o de Goldamnn foi realizada pelo teste de concordância de correlação (CCC) e graficamente pelo método de Bland-Altman. O valor de corte de 2 mmHg foi adotado para avaliar a empregabilidade clínica desses tonômetros em pacientes semelhantes aos da amostra. RESULTADOS: O teste de Kolmogorov-Smirnov indicou aceitação da normalidade para todas as distribuições estudadas (TAG, TPK, TCD, TNP, Diâmetros corneal e axial, ceratometria média e paquimetria). Os momentos de correlação de Pearson empregados para realizar estudo das correlações entre os parâmetros biométricos e cada tonometria foram estatisticamente não significativos. As correlações entre os parâmetros biométricos e as diferenças entre tonometrias em relação ao TAG não apresentaram significância em sua maioria, sendo a única exceção a correlação moderada entre a diferença do TAG e o Tono-Pen versus a ceratometria média. No entanto, o coeficiente de determinação evidenciou influência modesta da ceratometria nessas diferenças (r² = 0,16; p = 0,004). O teste t de Student pareado demonstrou diferença significativa entre o TAG e o TP (p < 0,001). A diferença não foi significativa entre o TAG e o Pascal (p = 0.30), ou entre o TAG e o Tono-Pen (p = 0.68). Houve excelente concordância entre o TAG e o TP (CCC = 0,98; intervalo de confiança 95% (IC95%) = 0,97 - 0,99), já entre o TAG e o Pascal (CCC = 0,89; IC95% = 0,82 - 0,94) e entre o TAG e o Tono-Pen (CCC = 0,92; IC95% = 0,87 - 0,95). O gráfico tipo Bland-Altman TAG x Perkins demonstrou diferença média de 0,47 mmHg com intervalo de 95% (I95%) situado entre -0,98 e 1,92 mmHg. A dispersão das diferenças seguiu caráter aleatório. Os outros dois tonômetros também tiveram suas dispersões em caráter aleatório. TAG em relação ao tonômetro de Pascal apresentou diferença média de -0,3 mmHg (I95% = -4,2 a 3,6 mmHg). A diferença média do TAG em relação ao Tono-Pen foi de -0,1 mmHg (I95% = -3,7 a 3,5 mmHg). Em 21% dos pacientes, o tonômetro de Pascal apresentou diferenças maiores de 2 mmHg em relação ao TAG, ao passo que no Tono- Pen essa proporção foi de 17,3%, e o tonômetro de Perkins não apresentou em nenhum dos pacientes diferenças maiores que estes limites. CONCLUSÕES: A ceratometria, paquimetria e os diâmetros axial e corneal não se correlacionaram com a PIO obtida por meio do TAG, tonômetro de Perkins, Pascal ou Tono-Pen. As diferenças tonométricas entre TAG (padrão ouro) e os outros tonômetros também não se correlacionaram com esses parâmetros biométricos, com exceção da ceratometria média, que se correlacionou positiva e moderadamente com a diferença da PIO entre TAG e Tono-Pen. O tonômetro de Perkins apresentou concordância substancial com o TAG, já o Tono-Pen e o TCD apresentaram concordâncias moderadas, sendo a concordância do Tono-Pen maior que a do TCD<br>OBJECTIVES: To compare the values of intraocular pressure (IOP) obtained by Perkins tonometer (PKT), Pascal dynamic contour tonometer (DCT) and Tono-Pen (TP), comparing then with Goldmann applanation tonometry (GAT), analyzing their correlations with ocular biometric parameters in patients with primary congenital glaucoma. METHODS: Prospective and cross-sectional study, including 46 patients (46 eyes) diagnosed with primary congenital glaucoma, between 12 and 40 years old, after obtaining informed consent. Keratometry was performed, followed by Goldmann applanation tonometry, Perkins tonometry, DCT and TP. The order of tonometries was randomized. The Goldmann tonometer was adopted as the gold standard. Ultrasound pachymetry, ultrasound biometry and corneal diameter measurement with surgical compass were also performed. The distributions of biometric parameters, as well as the tonometries were plotted and analyzed using Kolmogorov-Smirnov for acceptance of normality. Paired Student\'s t test for independent samples was used to compare the means of each tonometry with the gold standard. The correlations between biometric parameters and tonometries were performed by Pearson\'s product moment correlation coefficient and linear regression plots. The same procedure was done between biometric parameters and the differences between the three distinct tonometries and Goldmann tonometry. The agreement between tonometers and the GAT was performed through concordance correlation coefficient (CCC) and graphically by the Bland-Altman method. End point of 2 mmHg was adopted to evaluate clinical employability of these tonometers in patients with similar conditions. RESULTS: The Kolmogorov-Smirnov indicated acceptance of normality for all distributions studied (GAT, PKT, DCT, TP, corneal diameter, axial length, keratometry and pachymetry). All the Pearson´s product moment correlation coefficients between biometric parameters and each tonometry were not significant. The correlations between the biometric parameters and the differences between tonometries compared to the gold standard were not significant in most cases. The only exception was a positive and moderate correlation between the difference of the GAT and Tono-Pen versus the keratometry. The determintation coefficient revealed a considerable, but no large influence of K on the differences between GAT and Tono-Pen (r² = 0.16; p = 0.004). Student\'s paired t test showed a significant difference between GAT and PT (p < 0.001). The difference was not significant between the GAT and Pascal (p = 0.30), or between the GAT and Tono-Pen (p = 0.68). There was excellent agreement between GAT and PT (CCC = 0.98, 95% confidence interval (95% CI) = 0.97 to 0.99), as between GAT and Pascal (CCC = 0.90, 95% CI = 0.82 to 0.94) and between GAT and Tono-Pen (CCC = 0.92, 95% CI = .87 to .95). Bland-Altman plot GAT x Perkins showed a mean difference of 0, 47 mmHg with 95% CI located between -0.98 and 1.92 mmHg. The distribution of the IOP differences was aleatory. The other two differences` distributions also had aleatory characteristics. When comparing GAT with Pascal, the mean difference was -0.3 mmHg (95% CI = -4.2% to 3.6 mmHg). Mean difference between GAT and Tono-Pen was -0.1 mmHg (95% CI = -3,7 to 3.5 mmHg). Pascal tonometer showed a difference greater than 2 mmHg comparing to GAT in 21% of the patients, while with Tono-Pen this ratio was 17.3% and the Perkins tonometer did not present in any patient differences greater than these limits. CONCLUSIONS: The keratometry, pachymetry, corneal diameter and axial length did not correlate with IOP obtained by GAT, Perkins tonometer, Tono-Pen or Pascal. The differences between GAT (gold standard) and the other tonometers also did not correlate with these biometric parameters, with the exception of corneal curvature, which was positive and moderately correlated with the difference in IOP between GAT and Tono-Pen. GAT and Perkins tonometer showed substantial agreement, although Tono-Pen and DCT showed moderate agreement with GAT. The concordance obtained with Tono-Pen was higher than the concordance obtained with DCT
APA, Harvard, Vancouver, ISO, and other styles
41

Ilizarbe, Vargas Miguel Hernán. "Relación de la curvatura corneal central con los cambios de presión intraocular en pacientes operados de extracción extracapsular de catarata." Bachelor's thesis, Universidad Nacional Mayor de San Marcos, 2006. https://hdl.handle.net/20.500.12672/16043.

Full text
Abstract:
La presión intraocular (PIO) es la presión tisular más alta del organismo, semejante a la del líquido cefalorraquídeo. La PIO representa un factor fundamental de salud y enfermedad ocular. El presente estudio busca evaluar la influencia de la curvatura corneal central (CCC) en el resultado de la lectura tonométrica en pacientes sometidos a cirugía electiva de extracción extracapsular de catarata (EECC). En un estudio clínico prospectivo analítico se examinaron 19 pacientes programados electivamente a cirugía de EECC. El resultado de las mediciones de la CCC fue realizado por promedio de la queratometría y el grosor corneal central (GCC) por un paquimetría. El análisis estadístico fue realizado utilizando el programa informático Prism, con el análisis de varianza (ANOVA), T-student y correlación de datos. Así pues, resultó que la variación promedio de la PIO fue de 3.5 ± 0.5 mmHg en el grupo de pos operados de EECC con incremento de PIO y cambio de CCC. La variación promedio de PIO fue de 2.2 ± 1.24 mmHg en los post-operados de EECC con incremento de PIO sin cambio de CCC. Se encontró correlación entre el incremento de la PIO y el incremento de la CCC en los post operados de EECC (p<0.05). Se llegó a la conclusión que la CCC afecta el resultado de la lectura de la PIO obtenida por TAG en pacientes sometidos a cirugía de catarata por EECC. El riesgo de incrementar la PIO es 2.75 veces mayor en los pacientes que presentan aumento de la CCC respecto a los que no presentan incremento de CCC (RR 2.75), lo que es estadísticamente significativo. Mientras que el riesgo de incrementar la CCC es 1.7 veces mayor en los pacientes que presentan aumento de PIO respecto a los que no incrementan la PIO.
APA, Harvard, Vancouver, ISO, and other styles
42

Verbois, Thomas Régnier Alain. "Répétabilité et reproductibilité de la mesure de la pression intraoculaire avec le TonoPen chez le chien." [S.l.] : [s.n.], 2008. http://oatao.univ-toulouse.fr/2091/1/celdran_2091.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
43

Pinheiro, Renato Klingelfus. "Revisão interna de Simmons: análise de seus resultados clínicos e complicações." Universidade de São Paulo, 2007. http://www.teses.usp.br/teses/disponiveis/5/5149/tde-19042007-101817/.

Full text
Abstract:
INTRODUÇÃO: É importante estudar a efetividade da trabeculectomia e estratégias para manter sua ação ao longo do tempo. Para melhorarmos o prognóstico das revisões cirúrgicas é imprescindível entendermos melhor a estrutura da bolha filtrante e suas possíveis causas de falência. Formas alternativas para se restabelecer a drenagem e o funcionamento da trabeculectomia não funcionante foram desenvolvidas, entre elas a Revisão Interna de Simmons. OBJETIVOS: Avaliar os efeitos da Revisão Interna de Simmons sobre a PIO; sobre o aspecto biomicroscópico da bolha no pós-operatório e sua correlação com achados biométricos obtidos pela biomicroscopia ultra-sônica. CASUÍSTICA E MÉTODOS: Foram incluídos e estudados de forma prospectiva por 6 meses, 29 pacientes portadores de glaucoma primário, submetidos a trabeculectomia prévia,há pelo menos três meses, que apresentavam PIO acima do esperado para o controle do glaucoma, apesar de medicação hipotensora utilizada. Foram fatores de inclusão a conjuntiva livre e o óstio interno da trabeculectomia patente à gonioscopia. O critério de sucesso foi: abaixamento da PIO, igual ou maior que 30% da PIO em relação à PIO pré-operatória e/ou pressão final menor ou igual a 15mmHg, com ou sem medicação antiglaucomatosa associada. RESULTADOS: Houve uma queda estatisticamente significante da PIO e do número de medicações utilizadas após a cirurgia. A PIO média antes da operação era de 23,72 ± 4,10 mmHg e ao término do estudo, de 15,04 ± 4,00 mmHg (p=0,000016). A média das pressões da curva tonométrica antes da cirurgia era de 22,36 ± 3,91mmHg, caindo para 15,01 ± 3,95mmHg no PO180d (p=0,0000001). Antes da cirurgia, a média do número de medicações usadas era de 2,1 ± 0,77 e ao término do estudo, 1,22 ± 1,01 (p=0,001117). Houve um aumento do tamanho da bolha filtrante, avaliado pela biomicroscopia. As bolhas apresentaram altura média de 0,28 ± 0,65 e terminaram o estudo com altura de 0,78 ± 0,85 (p=0,000016). Não houve diferença na altura da bolha, medida pela biomicroscopia ultra-sônica após a cirurgia. A pressão intra-ocular apresentou relação inversamente proporcional à dimensão da bolha filtrante, com significância estatística. As complicações mais encontradas foram: descolamento da membrana de Descemet, no local da incisão principal em 5 doentes (17,2%), abertura inadvertida da conjuntiva em 4 (13,8%), e descolamento de coróide, em 3 (10,3%). CONCLUSÕES: A Revisão Interna de Simmons proporcionou diminuição de 30% da PIO em 52% dos pacientes e redução do número de medicações antiglaucomatosas associadas, quando utilizadas. As bolhas se mostraram-se estatisticamente maiores após o procedimento. Houve uma correlação perfeita entre a classificação da altura da bolha entre a medida biomicroscópica baseada na escala de Indiana e a biométrica obtida pela biomicroscopia ultra-sônica. Não houve aplanamento da curva tonométrica apesar desta ter diminuído 32%. Não foi observada mudança significativa no vício de refração ou na acuidade visual após a operação. A biomicroscopia ultra-sônica demonstrou uma associação inversa entre um maior número de complicações pós-operatórias e o tamanho menor do óstio interno da trabeculectomia.<br>INTRODUCTION: It is important to study the trabeculectomy effectiveness and strategies to keep its action within long time. To improve the prognostic presented on glaucoma surgical reviews it is essential to understand better the bleb structure and its possible cause of failing. Alternative ways of restoring the drainage and the good performance of trabeculectomy have been studied, among them the Internal Revision of Simmons. PURPOSE: Evaluate the surgery effects on the IOP; on the biomicroscopic aspect of the bleb and its co-relation with biometric founding gotten through UBM. METHODS: For six months, 29 patients with open angle glaucoma who had been submitted to trabeculectomy before, for at least three months, with IOP above the expected to the control of glaucoma, despite the medication used, were included and studied in a prospective way. These patients should present the conjunctive tissue not too scarry and internal ostio of trabeculectomy present on the gonioscopia. The success criterion was: lowering the IOP, equal or above 30% on pre-operatory IOP and/or final pressure below 15 mmHg, with or without eye drops. RESULTS: There was a statistically fall of IOP and amount of medication used after the surgery. The average of IOP before surgery was 23.27 ± 4.10 mmHg and at the end of study was 15.04 ± 4.00 mmHg (p=0.000016). The average of the IOP curve pressure before surgery was 22.36 ± 3.91mmHg, dropped to 15.01 ± 4.0 mmHg at PO180d (p=0.0000001). Before the surgery the average of medication used was 2.1 ± 0.77 and at the end of the study it was 1.22 ± 1.01 (p=0.001117). There was an increase of the filtering bleb size clinically measured. The blebs had an average height of 0.28 ± 0.65 and at the end of the study their height was 0.78 ± 0.85 (p=0.000016). The UBM didn?t show any difference in the bleb size. The intra-ocular pressure presented an inversely proportional relation to the dimension of the filtering bleb, with statistic significance. The most frequently problems found were: detachment of Descemet membrane where the main incision was performed, in 5 (17.28%) patients; hole in the conjuntiva in 4 (13.88%), detachment of the choroid in 3 (10.38%). CONCLUSIONS: The surgery was effective, for provided 30% decrease of initial IOP in 52% without or with eye drops statistically in small number than in presurgery. The blebs have appeared, statistically, bigger after the procedure. There was a perfect correlation between the bleb height classification, within the clinical measurement, based on the Indian scale, and the biometric one, gotten by UBM. There was no flattening of the IOP curve pressure despite this one had been 32% lower than the initial one. No significant change has occurred in the vicious of refraction or in the visual accuracy after the surgery. The UBM demonstrated an association between a larger number of complications post-surgery and the internal size of the trabeculectomy ostio.
APA, Harvard, Vancouver, ISO, and other styles
44

Soro, Martínez María Isabel. "Estudio del endotelio corneal y de la presión intraocular en pacientes intervenidos de glaucoma y catarata en uno o dos tiempos." Doctoral thesis, Universidad de Murcia, 2015. http://hdl.handle.net/10803/308672.

Full text
Abstract:
OBJETIVOS Determinar los cambios en la morfología y la disminución de la densidad de células endoteliales corneales tras la cirugía de glaucoma y catarata en uno ó dos tiempos, y analizar cuál de los dos tipos de cirugía produce mayor daño endotelial. Determinar la disminución de la presión intraocular tras la cirugía de glaucoma y catarata en uno ó dos tiempos y analizar cuál de los dos tipos de cirugía produce una mayor disminución de la Presión intraocular y/o mayor estabilidad de ésta en el postoperatorio. MATERIAL Y MÉTODOS Este es un estudio prospectivo randomizado y aleatorizado realizado en 46 ojos de 39 pacientes, con edad comprendida entre 66 y 80 años que padecían glaucoma y catarata. Los pacientes fueron seleccionados aleatoriamente para ser intervenidos de trabeculectomía y facoemulsificación con implante de lente intraocular (LIO) en uno (Grupo 1) o dos tiempos (Grupo 2), después de dar su consentimiento informado. Se recogieron de los pacientes varios tipos de datos: demografía, mejor agudeza visual corregida, evaluación del endotelio corneal mediante microscopia confocal (Confoscan 4™), medición del espesor corneal mediante biometría ultrasónica (Ocuscan®), medida de la profundidad de la cámara anterior con un biómetro óptico (IOLMaster®). Los pacientes fueron examinados previamente a la cirugía y 3, 6, 12 y 24 meses tras la cirugía. El análisis estadístico se llevó a cabo mediante el software Minitab® siguiendo los estándares publicados en la literatura clínica. RESULTADOS La Mejor Agudeza Visual corregida aumentó de forma significativa en los dos grupos después de la cirugía (p<0,0001) y la presión intraocular disminuyó de forma significativa en los dos grupos tras la cirugía (p<0,0001) pero no se observaron diferencias significativas (p=0,568 al mes, p=0,629 a los tres meses, p=0,208 a los seis meses y p=0,838 a los doce meses) entre los grupos en ninguno de los tiempos estudiados. El número medio de fármacos hipotensores tópicos se redujo de 1,21±0,55 a 0,20±0,43 colirios en el grupo 1 y 1,26±0.2 a 0,25±0,46 colirios en el grupo 2 a los 12 meses del estudio, no existiendo diferencias estadísticamente significativas (p=0,704) entre los dos grupos. La densidad endotelial disminuyó de forma significativa en ambos grupos tras la cirugía (p<0,0001). La densidad endotelial a los 12 meses de la cirugía fue de 1.769± 509 células/mm2 en el grupo 1 y de 1.396±514 células/mm2 en el grupo 2, siendo esta diferencia estadísticamente significativa (p<0,0001). El porcentaje medio de reducción de células endoteliales fue de 31,62±14,73 % en el grupo 1 y de 42,55±17,68 % en el grupo 2 a los 12 meses de estudio. El coeficiente de variación celular no varió de forma significativa en ninguno de los dos grupos tras la cirugía, sin embargo el coeficiente de hexagonalidad disminuyó de forma significativa en el grupo 2. No se encontró una correlación significativa entre la disminución de la densidad de células endoteliales y la profundidad de la cámara anterior preoperatoria ni tampoco entre esta densidad y el espesor corneal central previo a la cirugía en ninguno de los grupos, aunque tampoco se observaron edemas corneales clínicamente significativos en ninguno de los ojos incluidos en el estudio.<br>OBJECTIVES To assess changes in morphology and density of the corneal endothelial cells after glaucoma and cataract surgery in one or two stages and to analyze which type of surgery causes most damage to the corneal endothelial cells. To assess the decrease of the intraocular pressure after glaucoma and cataract surgery in one or two stages and to analyze which type of surgery causes a greater decrease of the intraocular pressure and more stability of the intraocular pressure in the postoperative period. METHODS This is a randomized prospective cohort study that included 46 eyes with glaucoma and cataract from 39 patients aged between 66 and 80 years. Informed consent was obtained, after which the patients and were randomly assigned to receive trabeculectomy and phacoemulsification and intraocular lens (IOL) implantation in one (Group 1) or two stages (Group 2). Demographic as well as other parameters were determined: Best Corrected Visual Acuity (BCVA), corneal endothelial cell status (using confocal microscopy with the Confoscan 4™), central corneal thickness (using ultrasonic biometry Ocuscan®) and anterior chamber depth (using optic biometry IOLMaster®). Patients were assessed prior to surgery and 3,6,12 and 24 months after surgery. Statistical analysis was performed using the software Minitab® and published international clinical standards. RESULTS Best corrected visual acuity increased significantly in both groups after surgery (p<0.0001) and the intraocular pressure diminished significantly in both groups after surgery (p<0.0001), but there were not significant differences between groups at any of the periods studied (at one month, p=0.568; at three months, p=0.629; at six months, p=0.208; and at twelve months, p=838). Mean number of topical ocular hypotensive treatments diminished from 1.21±0.55 to 0.20±0.43 in Group 1 and from 1.26±0.2 to 0.25±0.46 in Group 2 twelve months after surgery and there were no significant differences between groups (p=0.704). Corneal endothelial cell density decreased significantly after surgery in both groups (p<0.0001). Endothelial cell density 12 months after surgery was 1,769± 509 cells/mm2 in Group 1 and 1,396±514 cells/mm2 in group 2, and this difference was statistically significant (p<0.0001). Mean percentage of decrease of corneal endothelial cells was 31.62±14.73% in Group 1 and 42.55±17.68% in Group 2, twelve months after surgery. The variation coefficient did not change significantly in any of the groups with surgery, but the hexagonality coefficient decreased significantly after surgery in Group 2. There was no significant correlation between the decrease of the endotelial cell densities and the preoperative anterior chamber depth or the preoperative central corneal thickness in any of the groups. However, we did not observe any clinically significant corneal edemas in any of the eyes included.
APA, Harvard, Vancouver, ISO, and other styles
45

Himber, Jacques. "Caracterisation des recepteurs adrenergiques des proces ciliaires : application a l'etude in vivo et in vitro d'antagonistes beta et d'agonistes alpha actifs sur la pression intra-oculaire." Université Louis Pasteur (Strasbourg) (1971-2008), 1988. http://www.theses.fr/1988STR13231.

Full text
APA, Harvard, Vancouver, ISO, and other styles
46

Araújo, Candice Cristina Quirino de. "Efeito da redução da pressão intraocular sobre a camada de fibras nervosas retinianas e nervo óptico medido pela tomografia de coerência óptica." reponame:Repositório Institucional da UnB, 2013. http://repositorio.unb.br/handle/10482/13170.

Full text
Abstract:
Dissertação (mestrado)—Universidade de Brasília, Programa de Pós-Graduação em Ciências da Saúde, 2013.<br>Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2013-05-21T15:56:58Z No. of bitstreams: 1 2013_CandiceCristinaQuirinoAraujo.pdf: 1613577 bytes, checksum: 034c8c8d4b10aa239213238a797195cb (MD5)<br>Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2013-05-21T16:03:51Z (GMT) No. of bitstreams: 1 2013_CandiceCristinaQuirinoAraujo.pdf: 1613577 bytes, checksum: 034c8c8d4b10aa239213238a797195cb (MD5)<br>Made available in DSpace on 2013-05-21T16:03:51Z (GMT). No. of bitstreams: 1 2013_CandiceCristinaQuirinoAraujo.pdf: 1613577 bytes, checksum: 034c8c8d4b10aa239213238a797195cb (MD5)<br>Introdução: Glaucoma é uma neuropatia óptica progressiva, multifatorial, associada à perda de campo visual e às alterações no nervo óptico (NO) e camada de fibras nervosas retinianas (CFNR). Objetivo: Identificar alterações na CFNR e no NO, por meio da tomografia de coerência óptica (OCT), em pacientes com glaucoma primário de ângulo aberto (GPAA), submetidos a tratamento clínico e cirúrgico (trabeculectomia). Métodos: Foi realizada análise prospectiva de 37 olhos de 25 pacientes avaliados antes e após os tratamentos por meio da OCT, num período pré-tratamento (1 semana a 1 mês) e com 1, 3 e 6 meses após o tratamento. Os parâmetros medidos pela OCT foram analisados pelo teste de igualdade de médias e, para correlação entre as variáveis e a Po (pressão intraocular), foi utilizado o método de Pearson. Resultados: Os pacientes apresentaram redução da Po acima de 30%. O grupo clínico apresentou aumento da espessura média da CFNR total (p=0,009) e inferior (p = 0,007). Houve aumento da espessura média da CFNR superior, temporal e nasal, aumento da área de rima e diminuição do volume de escavação, entretanto sem significância estatística. O grupo cirúrgico apresentou aumento da espessura média da CFRN inferior e redução do volume de escavação quando correlacionados com a Po (p=0,004 / p= 0,02). Houve aumento da CFRN temporal, diminuição da área de escavação e aumento da área de rima, entretanto sem significância estatística. Conclusão: O grupo clínico apresentou aumento significante na espessura da CFNR. O grupo cirúrgico apresentou diminuição do volume de escavação e aumento da espessura da CFRN dependentes da redução da Po. ______________________________________________________________________________ ABSTRACT<br>Introduction: Glaucoma is a progressive optic neuropathy, multifactorial, associated with visual field loss and changes in the optic nerve (ON) and retinal nerve fiber layer (RNFL). Objective: To identify changes in the RNFL and ON by optical coherence tomography (OCT) in patients with primary open angle glaucoma (POAG)undergoing clinical and surgical treatment (trabeculectomy). Methods: We performed a prospective analysis of 37 eyes of 25 patients before and after treatment, by means of OCT, a pre-treatment period (1 week to 1 month) and with 1, 3 and 6 months after treatment. The parameters measured by OCT were analyzed by the test of equality of means and correlations between IOP and variables we used the method of Pearson. Results: The patients showed reduction of IOP above 30%. The clinical group had an increase in average total (p= 0,009) and inferior RNFL thickness (p = 0.007). There was an increase in average superior, temporal and nasal RNFL thickness, increase in rim area and decreased in cup volume, however not statistically significant. The surgical group had an increase in average inferior RNFL thickness and reducing in cup volume when correlated with IOP (p = 0.004 / p = 0.02). There was an increase in temporal RNFL thickness, decrease in cup area and increase in rim area, though not statistically significant. Conclusion: The clinical group showed significant increase in RNFL thickness. The surgical group showed decrease in the cup volume and increased RNFL thickness dependent reduction of IOP.
APA, Harvard, Vancouver, ISO, and other styles
47

Marchan, Pedro Rafael Apulcro Correa. "TONOMETRIA E ECOBIOMETRIA OCULAR EM TUCANO-TOCO (Ramphastos toco) E TUCANO-DE-BICO-VERDE (Ramphastos dicolorus)." Universidade Federal de Santa Maria, 2015. http://repositorio.ufsm.br/handle/1/4136.

Full text
Abstract:
The eyesight of birds is essential for their survival in a free environment; tiny alteration in this organ may cause loss of vision, consequently the difficulty or even the impossibility to hunt, move or protect themselves from predators; due to these particularities, the objective of this paper was to know the normal rate of intra-ocular pressure (IOP) and to identify the ocular anatomy through sonographic biometry in B-scan through transpalpebral way, so the ophthalmic examination can be complete and reliable. It was valued the IOP of 15 Toco Toucans (Ramphatos toco) and 15 Red-breasted Toucan (Ramphastos dicolorus) through applanation tonometry, using a Tono-Pen VET® tonometer and executed sonographic biometry ocular in 5 Toucans Toco and in 5 Red-breasted Toucan. The IOP from Toco Toucans, reliable in 95% got the media between 13,79 mmHg to17,61 mmHg, while the Red-breasted Toucan got the IOP between 12,05 mmHg and 16,81 mmHg. The ocular ultrasound eye was efficient as it could identify the previous segment, the lens, the posterior segment, positioning of the retina, Pecten and retrobulbar space. The Toco Toucans sonographic biometry obtained the bulbar average axial length of 1,66 cm, axial shaft of anterior segment 0,25 cm, shaft axial lens 0,35 cm axial shaft of posterior segment 1,05 cm, transverse shaft of the posterior segment 2,20 cm, transverse shaft of the lens 1,21 cm, and in Red-breasted Toucan the bulbar average axial length of 1,29 cm, axial shaft of anterior segment 0,10 cm, axial shaft lens 0,40 cm axial shaft of posterior segment 0,79 cm, shaft transverse of the posterior segment 1,39 cm, shaft transverse of the lens 0,99 cm. It follows that it is possible to measure IOP by tonometry with Tono-pen VET® tonometer and ocular sonographic biometry the B-scan transpalpebral, route is feasible for these species.<br>A visão das aves é fundamental para a sua sobrevivência em vida livre, pequenas alterações neste órgão, podem levar a perda da acuidade visual, consequentemente dificuldade ou mesmo impossibilidade em caçar, se locomover ou se defender de predadores. Devido a estas particularidades, o objetivo deste trabalho foi o de conhecer o valor normal da pressão intraocular (PIO) e identificar a anatomia ocular por meio da ecobiometria em modo B pela via transpalpebral, tornando o exame oftálmico mais completo e fidedigno. Foi avaliada a PIO de 15 Tucanos-toco (Ramphastos toco) e de 15 Tucanos-de-bico-verde (Ramphastos dicolorus) por meio da tonometria de aplanação, usando o tonômetro Tono-Pen VET®. Foi realizado ecobiometria ocular em 5 Tucanos-toco e 5 Tucanos-de-bico-verde. A PIO dos Tucanos-toco com 95% de confiança teve uma média entre 13,79 mmHg e 17,61 mmHg, já os Tucanos-de-bico-verde tiveram a PIO entre 12,05 mmHg e 16,81 mmHg. A ecografia ocular se mostrou eficiente pois foram identificados o segmento anterior, a lente, o segmento posterior, o posicionamento da retina, o pécten e o espaço retrobulbar. Na ecobiometria foram obtidos nos Tucanos-toco média do eixo axial bulbar de 1,66 cm, eixo axial do segmento anterior 0,25 cm, eixo axial do segmento posterior 1,05 cm, eixo transversal do segmento posterior 2,20 cm, eixo axial da lente 0,35 cm e eixo transversal da lente 1,21 cm, e nos Tucanos-de-bico-verde a média do eixo axial bulbar de 1,29 cm, eixo axial do segmento anterior 0,10 cm, eixo axial do segmento posterior 0,79 cm, eixo transversal do segmento posterior 1,39 cm, eixo axial da lente 0,40 cm e eixo transversal da lente 0,99 cm. Conclui-se que é possível mensurar a PIO por meio da tonometria de aplanação com o tonômetro Tono-pen VET® e que a ecobiometria ocular, em modo B pela via transpalpebral é viável para estas espécies.
APA, Harvard, Vancouver, ISO, and other styles
48

Wagatsuma, Juliana Tessália. "Anestesia peribulbar guiada por ultrassom com diferentes volumes de ropivacaína a 1 por cento associada ou não ao bicarbonato de sódio em cães /." Araçatuba, 2016. http://hdl.handle.net/11449/143898.

Full text
Abstract:
Orientador: Valéria Nobre Leal de Souza Oliva<br>Banca: Paulo Sérgio Patto dos Santos<br>Banca: Alexandre Lima de Andrade<br>Banca:Antonio José de Araújo Aguiar<br>Banca: Verônica Batista de Albuquerque<br>Resumo:Sete cães foram submetidos à anestesia inalatória com isoflurano para permitir a realização do bloqueio peribulbar, com punção única inferior, guiado por ultrassonografia com ropivacaína a 1%, e assim comprovar a eficácia desta técnica de bloqueio guiado na redução do volume anestésico injetado de ropivacaína a 1%, e avaliar possíveis efeitos potencializadores como a redução da latência e do volume anestésico utilizado, assim como complicações oftálmicas associadas à alcalinização do anestésico com bicarbonato de sódio a 0,33%. Foram avaliados dois volumes diferentes de ropivacaína a 1% (0,2 mL/Kg e 0,1 mL/Kg) associados ou não ao bicarbonato de sódio a 0,33% que, ao ser adicionado ao anestésico, elevou o pH da solução anestésica para 6,0. Uma vez realizado o bloqueio peribulbar, com punção única inferior, guiado por ultrassom o tempo necessário para ocorrer a centralização do bulbo do olho era cronometrado, e os animais permaneciam anestesiados para a aferição da pressão intraocular, que foi realizada imediatamente e 15 minutos após o bloqueio e, concluída essa mensuração, a anestesia foi encerrada. Com os cães já despertos foram avaliados os seguintes parâmetros: a pressão intraocular, o diâmetro pupilar, o bloqueio motor, sensitivo (realizado por meio de estesiometria corneal com estesiômetro de Cochet e Bonnet), e a observação das intercorrências oftálmicas como quemose, hiperemia conjuntival, hematoma subconjuntival, prurido e secreção ocular. As análises estatísticas foram conduzidas com o auxílio do software de livre acesso RStudio . Variáveis não paramétricas, ordinais e categóricas foram avaliadas por teste estatística tipo ANOVA ou ATS. Variáveis contínuas paramétricas foram avaliadas pelo Modelo linear misto para medidas repetidas. O Teste Kendall Tau-b foi utilizado... (resumo completo clicar acesso eletronico abaixo)<br>Abstract: Seven dogs were subjected to inhalation anesthesia with isoflurane to allow the realization of peribulbar block, with lower single puncture, guided by ultrasound with 1% ropivacaine, and thus prove the effectiveness of this blocking technique guided in reducing anesthetic volume of ropivacaine 1%, and evaluate possible potentiating effects such as reducing the latency and anesthetic volume used and ophthalmic complications associated with the anesthetic alkalinization with sodium bicarbonate 0,33%. We evaluated two different volumes of 1% ropivacaine (0.2 ml / kg and 0.1 ml / kg) with or without sodium bicarbonate to 0.33% which when added to anesthetic raised the pH of the solution anesthetic to 6.0. Once performed peribulbar block, with lower single puncture guided by ultrasound time required to place the centralization of the eye bulb was timed, and the animals remained anesthetized for the measurement of intraocular pressure was carried out immediately and 15 minutes after blockade and completed this measurement, anesthesia was terminated. With dogs the following parameters already awake were evaluated intraocular pressure, pupil size, the duration and intensity of motor block, sensory (performed by esthesiometry corneal with esthesiometer Cochet and Bonnet), and observation of ophthalmic complications as chemosis, conjunctival hyperemia, subconjunctival hematoma, pruritus, and ocular secretion resulting from the anesthetic technique or employee drug. Statistical analyzes... (Resumo completo, clicar acesso eletrônico abaixo)<br>Doutor
APA, Harvard, Vancouver, ISO, and other styles
49

Helzel, Milena Sefrin. "Relação da pressão intra-ocular e paquimetria corneal com os diferentes estágios de desenvolvimento das cataratas diabéticas e não diabéticas em cães da raça Poodle." Universidade de São Paulo, 2008. http://www.teses.usp.br/teses/disponiveis/10/10137/tde-08012009-100452/.

Full text
Abstract:
A diabetes mellitus (DM) causa alterações em todas as camadas da córnea. Córneas de pacientes diabéticos têm controle de sua hidratação prejudicado e são mais propensas à descompensação após injúria. A uveíte faco-induzida (UFI) ocorre em grandes proporções associada à catarata hipermatura em cães. A UFI também acarreta danos ao endotélio da córnea e pode levar ao edema estromal, usualmente transitório. Cães diabéticos são particularmente predispostos ao desenvolvimento de catarata e UFI associada. Os efeitos da DM e UFI podem potencialmente vir a se somar em córneas de cães com catarata diabética. A pressão intra-ocular (PIO) e paquimetria podem ser ferramentas úteis na determinação dessas alterações. O objetivo deste estudo foi determinar a relação entre pressão intra-ocular e paquimetria nos diferentes estágios de desenvolvimento das cataratas diabéticas e não diabéticas em cães da raça Poodle. Cento e vinte e dois cães adultos da raça Poodle, 134 fêmeas e 99 machos, com idades de 2 a 16 anos, foram admitidos no Serviço de Oftalmologia do Hospital Veterinário da Universidade de São Paulo e incluídos no trabalho. Afecções oculares concomitantes, ou doenças sistêmicas com manifestação ocular, foram consideradas fatores de exclusão. Após exame clínico oftalmológico, coletou-se dados referentes ao tempo de leucocoria e tempo de desenvolvimento da DM. Os cães tiveram a PIO mensurada por meio do TonoPen-XL® e a paquimetria mensurada com o uso do PachPen®. Para isso realizou-se anestesia tópica (colírio de Proximetacaína a 0,5% - Anestalcon®, Alcon). As comparações estatísticas entre as variáveis foram realizadas utilizando os testes de Spearman, Mc-Nemar e Mann-Whitney quando apropriados. As distribuições das variáveis entre os grupos foram avaliadas pelo test de Kruskal-Wallis, e quando significantes, o teste de Dunn foi utilizado para descriminar as diferenças encontradas. O nível de significância foi estabelecido em p<0,05. Dos 122 cães, 233 olhos foram incluídos e classificados em grupo controle (n=39), catarata incipiente (n=20), imatura (n=29), matura (n=20), hipermatura (n=80), catarata diabética imatura (n=9), diabética matura (n=11) e diabética hipermatura (n=25). As distribuições das variáveis (sexo, idade, peso, presença de uveíte, tempo de leucocoria, PIO e paquimetria) foram estatisticamente diferentes entre os diversos grupos. Fêmeas apresentaram-se mais acometidas por catarata diabética. A idade média dos animais variou de 7,03 a 10,73 anos entre os grupos, e os animais diabéticos foram estatisticamente mais velhos. A PIO foi estatisticamente menor e os sinais clínicos de UFI mais prevalentes nos grupos de cataratas hipermaturas, tanto diabéticas, quanto não diabéticas. A PIO correlacionou-se negativamente com a idade e a paquimetria. Houve correlação positiva da paquimetria com a idade e o peso; e correlação negativa com o tempo de leucocoria e a PIO. Olhos acometidos por UFI tiveram PIO estatisticamente menor e paquimetria maior, com diferença de 2 mmHg e 60 µm, respectivamente. Nos cães acometidos por catarata diabética, a paquimetria encontrou-se particularmente aumentada, e a UFI particularmente presente. Esse aumento possivelmente reflete a somatória dos efeitos da DM e UFI sobre a córnea. A hipermaturidade foi correlacionada à presença da UFI. A PIO e paquimetria mostraram-se instrumentos valiosos na determinação da UFI, principalmente se forem negativamente correlacionadas entre si.<br>Diabetes mellitus (DM) causes different alterations in all corneal layers, such as deficient control of hydration, what makes them prone to decompensate after injury. Lens induced uveitis (LIU) occurs mainly in dogs presenting hypermature cataracts, what causes irreversible damages to the corneal endothelium and may lead to stromal edema, usually transient. DM dogs are particularly predisposed to cataract with LIU associated. Intraocular pressure (IOP) and pachymetry measurements may be useful procedures capable to detect such alterations. The aim of this study was to determinate the relationship between intraocular pressure and pachymetry on diabetic and nondiabetic Poodles, presenting different stages of cataracts. One hundred twenty-two Poodles, 134 females and 99 males, with ages varying from 2 to 16 years, were admitted at the Ophthalmology Service, of the Veterinary Hospital, of the University of São Paulo. After complete identification of the animals, anamnese (time of DM and cataract formation) and ophthalmological exam, dogs were included in the study. Dogs affected by other systemic diseases inducing ocular manifestation or other primary ocular alteration were excluded. LIU was diagnosed by observation of congestion of the episcleral vases and resistence to midriasis after induction with Mydriacyl®. IOP was measured by TonoPen-XL® and pachymetry by PachPen® after instillation of anesthetic eyedrop (Proximetacaine 0,5% - Anestalcon, Alcon). Statistical comparison between factors were made using Spearman, Mc-Nemar and Mann-Whitney tests when appropriated. The distributions of the factors among the groups were compared by Krusskal-Walliss test, and when significant, Dunns test was used to describe the differences found. The level of significance was set at p<0,05. Two hundred thirty-three eyes of 122 Poodles were evaluated. Eyes were classified in different groups: healthy dogs without cataracts (n=39); dogs presenting incipient cataract (n=20); with immature cataracts (n=29); mature cataracts (n=20); or hypermature cataracts (n=80); DM dogs presenting immature cataract (n=9); DM with mature cataracts (n=11); and DM with hypermature cataracts (n=25). Distribution of factors, such as age, sex, weight, time of DM and cataract, presence of LIU, IOP and pachymetry were statistically different between groups. Female Poodles were more affected by diabetic cataract and diabetic dogs were older than the other ones. IOP was statistically lower and LIU alterations more prevalent in the hypermature cataract groups (diabetic and no diabetics). IOP was negatively correlated to age and pachymetry measures. Pachymetry was positively correlated to age and weight. Negative correlation was observed between pachymetry and time of cataracts formation. LIU eyes presented lower IOP and higher pachymetry. The difference found at pachymetry and IOP measurements in LIU and non LIU eyes were 60 µm and 2 mmHg respectively. In diabetic dogs, pachymetry was particularly higher and LIU particularly present. The higher corneal thickness may possible be related to the sum of alterations caused by DM and LIU to those corneas. Hypermaturity was directly related to LIU. We concluded that pachymetry and IOP measurements are important procedures to the LIU diagnosis, mainly when negatively correlated.
APA, Harvard, Vancouver, ISO, and other styles
50

Espindola, Rodrigo França de. "Comparação prospectiva e randomizada entre DisCo Visc e hidroxipropilmetilcelulose 2% durante a facoemulsificação." Universidade de São Paulo, 2015. http://www.teses.usp.br/teses/disponiveis/5/5149/tde-11012016-154124/.

Full text
Abstract:
INTRODUÇÃO: Comparar duas soluções viscoelásticas, ácido hialurônico 1,6%/sulfato de condroitina 4% (DisCoVisc®, Alcon Laboratórios, EUA) e hidroxipropilmetilcelulose 2% (HPMC, Ophthalmos, Brasil), com relação ao desempenho durante a facoemulsificação (FACO) e o implante de lente intraocular. MÉTODOS: Foi realizado um ensaio clínico randomizado, envolvendo 78 olhos (39 pacientes) submetidos à FACO bilateral, por um único cirurgião. Os pacientes foram randomizados para receber DisCoVisc ou HPMC no primeiro olho. O olho contralateral foi operado mais tarde recebendo a outra solução viscoelástica em todas as etapas da cirurgia. Examinadores mascarados realizaram as avaliações pré e pósoperatórias (5, 24 e 48 horas; 7 e 14 dias; 3 e 6 meses), incluindo a medida da pressão intraocular (PIO), espessura cornena central (ECC) e acuidade visual corrigida. A densidade endotelial foi realizada no pré-operatório e ao final do seguimento (6 meses). Variáveis intraoperatórias incluíram medidas da quantidade total de solução viscoelástica, tempo de ultrassom durante a FACO e tempo para a retirada completa da solução do olho. RESULTADOS: A densidade endotelial foi estatisticamente superior com DisCoVisc (2.214 ± 372 cel/mm2) do que com HPMC (2.032 ± 460 cel/mm2) ao final do seguimento (p = 0,001). Uma redução média de 7% e de 15%, respectivamente. Não houve diferença estatística entre as soluções viscoelásticas com relação a densidade da catarata (p = 0,363) e o tempo de ultrassom (p = 0,456). O tempo de aspiração da HPMC (0,22 ± 0,09 min) foi significativamente maior que o DisCoVisc (0,17 ± 0,06 min) (p = 0,001) e a quantidade de viscoelástico utilizada foi maior com a HPMC (1,35 ± 0,20 ml) do que com DisCoVisc (0,89 ± 0,11 ml) (p < 0,001). Não houve diferença estatisticamente significativa entre as soluções quanto a ECC e a PIO durante o seguimento. CONCLUSÕES: A densidade endotelial ao final do estudo foi significativamente maior com o uso de DisCoVisc, o que pode representar uma melhor proteção endotelial. Foi necessário uma menor quantidade de DisCoVisc e um tempo de aspiração menor durante a FACO com essa solução viscoelástica<br>INTRODUCTION: To compare two ophthalmic viscosurgical devices (OVDs), 1.6% hyaluronic acid/4% chondroitin sulfate (DisCoVisc®, Alcon Lab., USA) and 2% hydroxypropylmethylcellulose (HPMC, Ophthalmos, Brazil), in terms of their overall performance during phacoemulsification (PHACO) and intraocular lens implantation. METHODS: This prospective, randomized clinical trial comprised 78 eyes (39 patients) that underwent PHACO by the same surgeon. Patients were randomly assigned to receive DisCoVisc or HPMC on the first eye. The other eye was treated later and received the other OVD. Masked examiners measured intraocular pressure (IOP), central corneal thickness (CCT) and best-corrected visual acuity. The corneal endothelial cell density was measured at baseline and at 6 months postoperatively. Intraoperative variables include the total amount of the OVD, ultrasound and washout times. RESULTS: Corneal endothelial cell density was significantly higher with DisCoVisc (2.214 ± 372 cell/mm2) than HPMC (2.032 ± 460 cell/mm2) at the end of follow-up (p = 0.001). A mean reduction of 7% and 15%, respectively. There were no statistically significant differences between OVDs in terms of cataract density (p = 0.363) or ultrasound time (p = 0.456). Regarding washout time, it took longer to remove HPMC (0.22 ± 0.09 min) than DisCoVisc (0.17 ± 0.06 min) (p = 0.001), and the amount of viscoelastic material used was greater with HPMC (1.35 ± 0.20 ml) than DisCoVisc (0.89 ± 0.11 ml) (p < 0.001). There were no statistically significant differences between the two OVDs regarding CCT or IOP measurements at any point in time. CONCLUSION: The corneal endothelial cell loss was significantly less with DisCoVisc than HPMC, which can improve corneal endothelium protection. DisCoVisc was easier to remove after IOL implantation and fewer amounts were necessary during PHACO
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!