To see the other types of publications on this topic, follow the link: Probe-forming system.

Journal articles on the topic 'Probe-forming system'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 journal articles for your research on the topic 'Probe-forming system.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse journal articles on a wide variety of disciplines and organise your bibliography correctly.

1

Lebed, S. A. "A two-regime probe-forming system for modern nuclear nanoprobes." Technical Physics 47, no. 1 (2002): 88–91. http://dx.doi.org/10.1134/1.1435895.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Wen, Jianguo, James Mabon, Changhui Lei, et al. "The Formation and Utility of Sub-Angstrom to Nanometer-Sized Electron Probes in the Aberration-Corrected Transmission Electron Microscope at the University of Illinois." Microscopy and Microanalysis 16, no. 2 (2010): 183–93. http://dx.doi.org/10.1017/s1431927610000085.

Full text
Abstract:
AbstractWe evaluate the probe forming capability of a JEOL 2200FS transmission electron microscope equipped with a spherical aberration (Cs) probe corrector. The achievement of a real space sub-Angstrom (0.1 nm) probe for scanning transmission electron microscopy (STEM) imaging is demonstrated by acquisition and modeling of high-angle annular dark-field STEM images. We show that by optimizing the illumination system, large probe currents and large collection angles for electron energy loss spectroscopy (EELS) can be combined to yield EELS fine structure data spatially resolved to the atomic sc
APA, Harvard, Vancouver, ISO, and other styles
3

Shao, Zhifeng. "On the fifth order aberration in a sextupole corrected probe forming system." Review of Scientific Instruments 59, no. 11 (1988): 2429–37. http://dx.doi.org/10.1063/1.1139922.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Magilin, D. V., A. G. Ponomarev, V. A. Rebrov, et al. "Performance of the Sumy nuclear microprobe with the integrated probe-forming system." Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms 267, no. 12-13 (2009): 2046–49. http://dx.doi.org/10.1016/j.nimb.2009.03.015.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Jamieson, D. N., C. G. Ryan, and S. H. Sie. "Measurement of the aberrations of an electrostatic quadrupole probe forming lens system." Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms 54, no. 1-3 (1991): 33–37. http://dx.doi.org/10.1016/0168-583x(91)95486-w.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Ponomarev, A. G., G. S. Vorobjov, and A. A. Ponomarova. "Optimization of the quadrupole probe-forming system with individual power supplies for lenses." Radioelectronics and Communications Systems 53, no. 2 (2010): 113–18. http://dx.doi.org/10.3103/s0735272710020068.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Ignat’ev, I. G., D. V. Magilin, V. I. Miroshnichenko, A. G. Ponomarev, V. E. Storizhko, and B. Sulkio-Cleff. "Immersion probe-forming system as a way to the compact design of nuclear microprobe." Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms 231, no. 1-4 (2005): 94–100. http://dx.doi.org/10.1016/j.nimb.2005.01.040.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Breese, M. B. H., D. N. Jamieson, and B. L. Doyle. "The use of solenoid lenses in a two-stage nuclear microprobe probe-forming system." Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms 188, no. 1-4 (2002): 261–66. http://dx.doi.org/10.1016/s0168-583x(01)01110-7.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Matsuya, M., M. Saito, C. H. Nielsen, and S. Nakagawa. "The Large Depth of Focus (LDF) Mode in 3-Stage Lens System." Proceedings, annual meeting, Electron Microscopy Society of America 49 (August 1991): 990–91. http://dx.doi.org/10.1017/s0424820100089263.

Full text
Abstract:
The Large Depth of Focus (hereinafter abbreviated to LDF) mode has been developed. The depth of focus in the LDF mode has been made 3 to 5 times larger than that in a conventional probe forming system by changing the positions of imaging points in the 3-stage lens system. The LDF mode has been applied successfully to observing the specimen with a large height difference (2 mm) without defocus and to analyzing it by EDS.
APA, Harvard, Vancouver, ISO, and other styles
10

Sawada, Hidetaka, Christopher S. Allen, Shanshan Wang, Jamie H. Warner, and Angus I. Kirkland. "Aberration measurement of the probe-forming system of an electron microscope using two-dimensional materials." Ultramicroscopy 182 (November 2017): 195–204. http://dx.doi.org/10.1016/j.ultramic.2017.06.024.

Full text
APA, Harvard, Vancouver, ISO, and other styles
11

Huang, Letao, Shiwu Li, Xia Ling, et al. "Dual detection of bioaccumulated Hg2+ based on luminescent bacteria and aggregation-induced emission." Chemical Communications 55, no. 52 (2019): 7458–61. http://dx.doi.org/10.1039/c9cc02782c.

Full text
Abstract:
We develop a dual detection strategy for bioaccumulated Hg<sup>2+</sup> based on turn-off of the bioluminescence of P. phosphoreum bacteria by disrupting the quorum sensing system and turn-on of the photoluminescence of an aggregation-induced emission (AIE) probe by forming aggregates with Hg<sup>2+</sup> inside the bacteria.
APA, Harvard, Vancouver, ISO, and other styles
12

Ignat'ev, I. G., V. I. Miroshnychenko, O. G. Ponomarev, and V. Yu Storizhko. "Optimization of the electrostatic structure of the ion microprobe." Nuclear Physics and Atomic Energy 13, no. 1 (2012): 97–100. https://doi.org/10.15407/jnpae2012.01.097.

Full text
Abstract:
The paper presents optimization data obtained for an immersion probe-forming system of the ion microprobe to be used in 3 MeV H+ ion accelerator generating 0.4 μm beam spot for normalized acceptance of 7 μm2 · mrad2 · MeV. To achieve higher microprobe resolution it is intended to place an electrostatic lens between the collimators and the accelerating tube.
APA, Harvard, Vancouver, ISO, and other styles
13

Sunko, V., F. Mazzola, S. Kitamura, et al. "Probing spin correlations using angle-resolved photoemission in a coupled metallic/Mott insulator system." Science Advances 6, no. 6 (2020): eaaz0611. http://dx.doi.org/10.1126/sciadv.aaz0611.

Full text
Abstract:
A nearly free electron metal and a Mott insulating state can be thought of as opposite ends of the spectrum of possibilities for the motion of electrons in a solid. Understanding their interaction lies at the heart of the correlated electron problem. In the magnetic oxide metal PdCrO2, nearly free and Mott-localized electrons exist in alternating layers, forming natural heterostructures. Using angle-resolved photoemission spectroscopy, quantitatively supported by a strong coupling analysis, we show that the coupling between these layers leads to an “intertwined” excitation that is a convolutio
APA, Harvard, Vancouver, ISO, and other styles
14

Xue YongMei, He YunHui, HanXiao Xuan, Bai JingXu, Jiao YueChun, and Zhao JianMing. "Investigation of partial PT symmetry in a cesium atomic system." Acta Physica Sinica 73, no. 22 (2024): 0. http://dx.doi.org/10.7498/aps.73.20241200.

Full text
Abstract:
Parity-Time reversal (PT) in atomic systems is of great significance for exploring an exotic phenomena in non-Hermitian physics and non-Hermitian systems. It has been found that if PT symmetry is satisfied only in a certain spatial direction, then the Hamiltonian of the system still has a spectrum with eigenvalues of real numbers, which is called partial PT symmetry. In this paper, we use a Λ-type three-level atomic system, composed of two ground states |6S&lt;sub&gt;1/2&lt;/sub&gt; F = 3&gt;, |6P&lt;sub&gt;3/2&lt;/sub&gt; F' = 4&gt; and excited state |6P&lt;sub&gt;3/2&lt;/sub&gt; F' = 4&gt; o
APA, Harvard, Vancouver, ISO, and other styles
15

Zerdoumi, Ridha, Thomas Quast, Emmanuel Batsa Tetteh, et al. "Integration of Scanning Electrochemical Microscopy and Scanning Electrochemical Cell Microscopy in a Bifunctional Nanopipette toward Simultaneous Mapping of Activity and Selectivity in Electrocatalysis." Analytical Chemistry 96, no. 27 (2024): 10886–92. https://doi.org/10.1021/acs.analchem.4c00149.

Full text
Abstract:
Scanning electrochemical microscopy (SECM) and scanning electrochemical cell microscopy (SECCM) were integrated in a single bifunctional probe for simultaneous mapping of the oxygen reduction current and the oxidation current of the produced H<sub>2</sub>O<sub>2</sub>. The dual probe is fabricated from a double-barrel &theta; capillary, comprising one open barrel filled with the electrolyte and another filled with pyrolytic carbon. Pt is deposited with a gas injection system (GIS) at the end of the carbon barrel. The probe integrates the advantages of both SECM and SECCM by forming an electroc
APA, Harvard, Vancouver, ISO, and other styles
16

Filipovic, Nikola, Vladan Pavlovic, and Ljiljana Stevanovic. "Slow and fast light propagation through ladder-type atomic media with degenerate energy levels." Facta universitatis - series: Physics, Chemistry and Technology 17, no. 2 (2019): 173–90. http://dx.doi.org/10.2298/fupct1902173f.

Full text
Abstract:
We investigate the weak probe pulse propagation through the atomic medium, in the presence of the strong control laser field, under the regime of the electromagnetically induced transparency (EIT). These fields couple to the medium by forming the 3-level ladder configuration. We focus on two distinct cases: closed system, which is a non-degenerate, and open system, where the middle level is 3-fold degenerate, and the additional levels are coupled to the other levels only via spontaneous emission. The spatio-temporal profile of the probe pulse envelope is obtained by using the formalism of Maxw
APA, Harvard, Vancouver, ISO, and other styles
17

Stopka, Jan, and Pieter Kruit. "Statistical Coulomb interactions in multi-beam SEM." International Journal of Modern Physics A 34, no. 36 (2019): 1942021. http://dx.doi.org/10.1142/s0217751x19420211.

Full text
Abstract:
Statistical Coulomb interactions in conventional scanning electron microscopy mostly affect the probe size via energy spread and virtual source broadening in the emitter vicinity. However, in a multi-beam probe forming system such as a multi-beam scanning electron microscopes (MBSEM), the trajectory displacement due to interactions in the whole column can give a contribution to the final probe size. For single-beam systems, this can be expressed using approximate formulae for the total trajectory displacement in a beam segment (Jansen’s theory) or by integrating contributions of infinitesimall
APA, Harvard, Vancouver, ISO, and other styles
18

Cugno, G., P. Patapis, T. Stolker, et al. "Molecular mapping of the PDS70 system." Astronomy & Astrophysics 653 (August 31, 2021): A12. http://dx.doi.org/10.1051/0004-6361/202140632.

Full text
Abstract:
Context. Determining the chemical properties of the atmosphere of young forming gas giants might shed light on the location their formation occurred and the mechanisms involved. Aims. Our aim was to detect molecules in the atmosphere of the young forming companion PDS70 b by searching for atmospheric absorption features typical of substellar objects. Methods. We obtained medium-resolution (R ≈ 5075) spectra of the PDS70 planetary system with the SINFONI integral field spectrograph at the Very Large Telescope. We applied molecular mapping, based on cross-correlation with synthetic spectra, to i
APA, Harvard, Vancouver, ISO, and other styles
19

Silaev, I. V., I. N. Goncharov, T. T. Magkoev, and T. I. Radchenko. "Method and Implementation of High-Performance Diagnostics of Form of Electron Probe of Raster Electron Microscope." Proceedings of Universities. ELECTRONICS 25, no. 6 (2020): 497–504. http://dx.doi.org/10.24151/1561-5405-2020-25-6-497-504.

Full text
Abstract:
An important unit of an electron microscope is the system controlling the electron beam, responsible for raster forming on the specimen and the electron probe focusing, which provides an achievement of minimum of aberrations and the maximum of resolving capacity of formed electron image. During using electron microscope the image quality gradually deteriorates, manifesting the resolving capacity reduction and the astigmatism appearance. An attachment developed for the raster electron microscope, permitting to perform the highly effective diagnostics of the configuration of the scanning electro
APA, Harvard, Vancouver, ISO, and other styles
20

Zhang, Liding, Xuewei Du, Zhixin Chen, et al. "Instrument-Free and Visual Detection of Salmonella Based on Magnetic Nanoparticles and an Antibody Probe Immunosensor." International Journal of Molecular Sciences 20, no. 18 (2019): 4645. http://dx.doi.org/10.3390/ijms20184645.

Full text
Abstract:
Salmonella, a common foodborne pathogen, causes many cases of foodborne illness and poses a threat to public health worldwide. Immunological detection systems can be combined with nanoparticles to develop sensitive and portable detection technologies for timely screening of Salmonella infections. Here, we developed an antibody-probe-based immuno-N-hydroxysuccinimide (NHS) bead (AIB) system to detect Salmonella. After adding the antibody probe, Salmonella accumulated in the samples on the surfaces of the immuno-NHS beads (INBs), forming a sandwich structure (INB–Salmonella–probes). We demonstra
APA, Harvard, Vancouver, ISO, and other styles
21

Dmitriyeva, Elena, Igor Lebedev, Ekaterina Bondar, et al. "The Influence of Lyophobicity and Lyophilicity of Film-Forming Systems on the Properties of Tin Oxide Films." Coatings 13, no. 12 (2023): 1990. http://dx.doi.org/10.3390/coatings13121990.

Full text
Abstract:
In this work, the effects of lyophobicity and lyophilicity of film-forming systems on the properties of thin nanostructured films was studied. Systematic series of experiments were carried out with lyophilic film-forming systems: SnCl4/EtOH, SnCl4/EtOH/NH4F, SnCl4/EtOH/NH4OH and lyophobic systems: SnO2/EtOH and SnO2/EtOH/NH4F. Film growth mechanisms are determined depending on the type of film-forming system. The surface of the films was studied using a scanning electron microscope and an optical microscope. The spectrophotometric method is used to study the transmission spectra and the extinc
APA, Harvard, Vancouver, ISO, and other styles
22

Uejima, Rino, Mai Sugimoto, Masakazu Arima, et al. "Development of in-Situ Electrochemical Megabalanus Roseusgene Measurement System." ECS Meeting Abstracts MA2024-02, no. 54 (2024): 3655. https://doi.org/10.1149/ma2024-02543655mtgabs.

Full text
Abstract:
In recent years, global warming due to greenhouse gases has become a serious problem, causing problems such as atmospheric CO2 concentration and temperature rise. On the other hand, since about 70% of the earth is ocean, it is expected that exploring changes in the ocean environment not only due to atmospheric gases but also due to greenhouse gases will lead to conservation of the global environment. In order to accurately understand and predict the marine ecological environment, we need to acquire chemical information such as CO2 concentration, salinity, and pH, physical information such as t
APA, Harvard, Vancouver, ISO, and other styles
23

Sawada, Hidetaka, Fumio Hosokawa, and Angus I. Kirkland. "Accurate Evaluation of Aberration for Probe-Forming System and Influence of Aberration on High-Resolution STEM image." Journal of Physics: Conference Series 902 (September 2017): 012012. http://dx.doi.org/10.1088/1742-6596/902/1/012012.

Full text
APA, Harvard, Vancouver, ISO, and other styles
24

Haider, M., and J. Zach. "State of the development of multipole correctors for a probe-forming system and a high-resolution 200kV TEM." Proceedings, annual meeting, Electron Microscopy Society of America 53 (August 13, 1995): 596–97. http://dx.doi.org/10.1017/s0424820100139354.

Full text
Abstract:
The development of modern high resolution electron microscopes has shown the emergence of new modern microscopes which are easy to operate and, more importantly, with which one can attain high resolution on a routine basis. However, the physical limit set by the inherent aberrations of electron lenses could not be overcome by simply optimising the geometry of the pole pieces. The only direct way to get rid of the aberrations of the round lenses is to use a corrector with which the resolution limiting aberrations can be compensated.For the observation of uncoated biological surfaces we started
APA, Harvard, Vancouver, ISO, and other styles
25

Rajapakshe, Buddhima U., Yonghao Li, Brian Corbin, Kaveesha J. Wijesinghe, Yi Pang, and Chathura S. Abeywickrama. "Copper-Induced Fluorescence Quenching in a Bis[2-(2′-hydroxyphenyl)benzoxazole]pyridinium Derivative for Quantification of Cu2+ in Solution." Chemosensors 10, no. 10 (2022): 382. http://dx.doi.org/10.3390/chemosensors10100382.

Full text
Abstract:
Accurate determination of Cu2+ in solution is crucial for preventing several disease conditions. Spectroscopy-based techniques for metal ion detection are promising methods due to their excellent sensitivity and rapid response time. In this work, we are reporting a newly synthesized 2-(2′-Hydroxyphenyl) benzoxazole-based compound, probe 2, by incorporating a vinyl pyridinium segment into the bis(HBO) 4 system. Probe 2 exhibited excellent specificity toward Cu2+ in solution. The ratiometric absorbance (λ440/λ370) and the quenching of fluorescence at λem ≈585 nm exhibited an excellent linear cor
APA, Harvard, Vancouver, ISO, and other styles
26

Xia, Zhu, Bian, Li, Liu, and Liu. "Highly Sensitive and Selective Colorimetric Detection of Creatinine Based on Synergistic Effect of PEG/Hg2+–AuNPs." Nanomaterials 9, no. 10 (2019): 1424. http://dx.doi.org/10.3390/nano9101424.

Full text
Abstract:
A colorimetric sensor, based on the synergistic coordination effect on a gold nanoparticle (AuNP) platform has been developed for the determination of creatinine. The sensor selects citrate stabilized AuNPs as a platform, polyethylene glycol (PEG) as a decorator, and Hg2+ as a linkage to form a colorimetric probe system (PEG/Hg2−–AuNPs). By forming hydrogen bond between the oxygen-containing functional groups of PEG and citrate ions on the surface of AuNPs, this probe shows good stability. PEG coordinated with Hg2+ synergistically and specifically on the surface of dispersed AuNPs, and the exi
APA, Harvard, Vancouver, ISO, and other styles
27

Lewis, K. L. M., J. A. Myers, F. Fuller, P. F. Tekavec, and J. P. Ogilvie. "Two-dimensional electronic spectroscopy signatures of the glass transition." Spectroscopy 24, no. 3-4 (2010): 393–97. http://dx.doi.org/10.1155/2010/342156.

Full text
Abstract:
Two-dimensional electronic spectroscopy is a sensitive probe of solvation dynamics. Using a pump–probe geometry with a pulse shaper [Optics Express15(2007), 16681-16689;Optics Express16(2008), 17420-17428], we present temperature dependent 2D spectra of laser dyes dissolved in glass-forming solvents. At low waiting times, the system has not yet relaxed, resulting in a spectrum that is elongated along the diagonal. At longer times, the system loses its memory of the initial excitation frequency, and the 2D spectrum rounds out. As the temperature is lowered, the time scale of this relaxation gro
APA, Harvard, Vancouver, ISO, and other styles
28

Veneklasen, Lee H. "An electron optical tool kit for transmission and surface electron microscopy." Proceedings, annual meeting, Electron Microscopy Society of America 49 (August 1991): 414–15. http://dx.doi.org/10.1017/s0424820100086374.

Full text
Abstract:
This speculative discussion is offered in memory of Prof. Ben Siegel's fascination with the science of microscope instrumentation. It views the microscope configuration as a set of tools for creating observational opportunities. The central element is a condensor/objective lens in which the specimen is immersed, and along whose axis lie conjugate image and diffraction planes. An illumination system sets up beam conditions, in mode l1, forming a parallel beam, and Mode l2 forming a probe at the center of the lens. A projection system determines the plane within the objective that is magnified o
APA, Harvard, Vancouver, ISO, and other styles
29

Wang, Cheng, Yongjun Shao, Kuanxin Huang, et al. "Ore-Forming Processes at the Xiajinbao Gold Deposit in Eastern Hebei Province: Constraints from EPMA and LA-ICPMS Analysis." Minerals 8, no. 9 (2018): 388. http://dx.doi.org/10.3390/min8090388.

Full text
Abstract:
The Xiajinbao gold deposit is located at the northern margin of the North China Craton. Hydrothermal pyrites belonging to three stages were identified: Py1; Py2; and Py3. Geochemical study of these pyrites was conducted using electron probe microanalysis and laser ablation inductively coupled plasma mass spectrometry to investigate the distributions of minor and trace elements, constrain pyrite genesis, and to obtain an improved understanding of the ore-forming processes. Py1 and Py2 contain high concentrations of Au and are interpreted to have been deposited from fluids from a dominantly magm
APA, Harvard, Vancouver, ISO, and other styles
30

Buttice, Kailee Joy, Adrien Couet, Ruchi Gakhar, and Qiufeng Yang. "Optical Chlorobasicity Determination in Molten ZnCl2-KCl Via UV-Vis Spectroscopy." ECS Meeting Abstracts MA2024-02, no. 57 (2024): 3789. https://doi.org/10.1149/ma2024-02573789mtgabs.

Full text
Abstract:
The goal of this research is to construct a basicity scale for molten halide salts to quantitively determine the effect of salt composition on structural material corrosion. Optical basicity is a quantity derived from the UV-Vis spectra of p-block transition metal ions dissolved as probes in a molten salt and is primarily dependent on the amount of free halide within the melt. The outer orbitals of the probe ions are compacted through interaction with halide anions within the salt, lowering the s-p excitation energy and thus increasing optical basicity. Preliminary studies on bismuth as a prob
APA, Harvard, Vancouver, ISO, and other styles
31

Kamal, Surya, Yongjian Zhou, and Zizhou Gong. "Wave Optical Modeling of the SEM Column From Source to Specimen." Microscopy and Microanalysis 30, no. 5 (2024): 866–77. http://dx.doi.org/10.1093/mam/ozae072.

Full text
Abstract:
Abstract Probe formation in scanning electron microscope (SEM) is often reduced to objective lens action modeling based on a point-spread function or Fourier transforms. In this study, we present the first complete wave optical modeling of the whole SEM column based on plane-by-plane propagation of the electron beam wavefunction without simplifying the optical system. We identify the challenges in plane-by-plane beam propagation and show how sampling limitations produce aliased results. Through a careful selection and combination of propagators, we have developed a general wave optical propaga
APA, Harvard, Vancouver, ISO, and other styles
32

Abramovich, S. N., V. N. Zavjalov, A. G. Zvenigorodsky, et al. "Optimization of the probe-forming system for a scanning nuclear microprobe based on the ÉGP-10 electrostatic tandem accelerator." Technical Physics 50, no. 2 (2005): 146–51. http://dx.doi.org/10.1134/1.1866427.

Full text
APA, Harvard, Vancouver, ISO, and other styles
33

Sahoo, Gourishankar, Rita Paikaray, Subrata Samantaray, et al. "A Compact Plasma System for Experimental Study." Applied Mechanics and Materials 278-280 (January 2013): 90–100. http://dx.doi.org/10.4028/www.scientific.net/amm.278-280.90.

Full text
Abstract:
A compact plasma system is set up at Ravenshaw University, India. The plasma system consists of a curved vacuum chamber which is nothing but a part of a toroid (θ=700) having minor radius, r= 0.3 m and major radius, R= 0.5 m, vacuum system, electromagnet, gas injected washer stacked plasma gun to produce plasma blobs/filaments, pulse forming network to energise plasma gun, diagnostic tools like electric probes, magnetic probes, spectrometer, high speed CCD camera, digital pulse/delay generator to synchronise the diagnostic tools. A pair of copper coil is wound over the chamber and capacitive p
APA, Harvard, Vancouver, ISO, and other styles
34

Wirz, Dominic, Marc Hofmann, Heike Lorenz, Hans-Jörg Bart, Andreas Seidel-Morgenstern, and Erik Temmel. "A Novel Shadowgraphic Inline Measurement Technique for Image-Based Crystal Size Distribution Analysis." Crystals 10, no. 9 (2020): 740. http://dx.doi.org/10.3390/cryst10090740.

Full text
Abstract:
A novel shadowgraphic inline probe to measure crystal size distributions (CSD), based on acquired greyscale images, is evaluated in terms of elevated temperatures and fragile crystals, and compared to well-established, alternative online and offline measurement techniques, i.e., sieving analysis and online microscopy. Additionally, the operation limits, with respect to temperature, supersaturation, suspension, and optical density, are investigated. Two different substance systems, potassium dihydrogen phosphate (prisms) and thiamine hydrochloride (needles), are crystallized for this purpose at
APA, Harvard, Vancouver, ISO, and other styles
35

Perez-Caballero, David, Theodora Hatziioannou, Fengwen Zhang, Simone Cowan, and Paul D. Bieniasz. "Restriction of Human Immunodeficiency Virus Type 1 by TRIM-CypA Occurs with Rapid Kinetics and Independently of Cytoplasmic Bodies, Ubiquitin, and Proteasome Activity." Journal of Virology 79, no. 24 (2005): 15567–72. http://dx.doi.org/10.1128/jvi.79.24.15567-15572.2005.

Full text
Abstract:
ABSTRACT TRIM-CypA is an owl monkey-specific variant of the retrovirus restriction factor TRIM5α. Here, we exploit its modular domain organization and cyclosporine sensitivity to probe the kinetics and mechanism of TRIM5-mediated restriction. Time of addition/withdrawal experiments reveal that inhibition of incoming human immunodeficiency virus type 1 capsids by TRIM-CypA occurs within minutes of their delivery to the target cell cytoplasm. However, while TRIM-CypA restriction is partly dependent on a RING domain, restriction occurs independently of the ubiquitin/proteasome system. Moreover, t
APA, Harvard, Vancouver, ISO, and other styles
36

Yasuzawa, Mikito, Yusuke Sato, Takanori Kido, et al. "Preparation of Platinum Nanoelectrodes Using Tapered Tungsten Probes and Their Application to a Single Cell Measurement." ECS Meeting Abstracts MA2024-02, no. 65 (2024): 4340. https://doi.org/10.1149/ma2024-02654340mtgabs.

Full text
Abstract:
Platinum nanoelectrodes, which the electroactive region is located on the tip, were prepared in two steps. First, an insulating film was formed on the tapered tungsten probe by electrodeposition coating using the cationic electrodeposition paint, and then platinum nanopillars with a diameter of about 200 nm were formed on the tip using Focused-Ion-Beam Chemical-Vapor-Deposition (FIB-CVD). The conditions for forming an insulating film on tungsten surface with low thickness and excellent insulation properties were investigated and were evaluated by electrochemical measurements and SEM observatio
APA, Harvard, Vancouver, ISO, and other styles
37

J.Liu. "Effect of Specimen Bias on the Contrast of High Resolution Low Voltage SEM Images in a Semi-In-Lens JSM-6320f Fe-SEM." Microscopy and Microanalysis 3, S2 (1997): 1215–16. http://dx.doi.org/10.1017/s1431927600012964.

Full text
Abstract:
Nanometer-resolution surface imaging by secondary electrons (SE) is now routinely obtainable in field-emission SEM or STEM microscopes. The resolution in SE images obtained in a modern field-emission (FE) SEM is still limited by the electron probe size although the localization of the SE generation processes sets the ultimate resolution limit that will be achievable in SE images. The combination of a FE gun with improved probe forming lenses and detection systems makes it possible to image nanometer-scale surface features at low voltages. Because of the reduced electron beam range and the new
APA, Harvard, Vancouver, ISO, and other styles
38

Jakubowski, Tomasz, and Piotr Sołowiej. "Dynamics of Temperature Changes in Thermophille Phase of Composting Process in The Aspect of Sanitary Condition of Obtained Material." Agricultural Engineering 20, no. 4 (2016): 69–75. http://dx.doi.org/10.1515/agriceng-2016-0065.

Full text
Abstract:
Abstract A condition of obtaining compost with proper sanitary parameters is achieving the organic recycling process temperature which exceeds 7°C. The objective of the paper was to determine the temperature course in the compost tank for organic recycling of dead poultry in relation to the applied structure forming material. Wheat, oat, barley, rapeseed and corn straw were used as a structure-forming material. A measuring system was equipped with a probe with a temperature sensor with precision of ±0.15°C, transducer and data recorder. Results were prepared with the use of the analysis of var
APA, Harvard, Vancouver, ISO, and other styles
39

Zhang, Tian Heng, Dong Lin Peng, Ji Sen Yang, Xian Quan Wang, and Chun Dong. "Automatic Positioning Closed-Loop Control Cystem Design of Linear Time Grating Sensor." Advanced Materials Research 328-330 (September 2011): 2121–24. http://dx.doi.org/10.4028/www.scientific.net/amr.328-330.2121.

Full text
Abstract:
A high-precise automatic positioning system for data sample of linear time grating sensor is designed. In order to achieve linear time grating sensor of data sample, improve measure work efficiency, an ARM MCU is used as a major chip to control the stepper motor to rotate. In this way, the stepper motor drives the ball screw, the moving probe of linear time grating sensor and reading head of linear grating to move synchronously. A high-precision automatic positioning of the system hardware is designed. In addition, ARM controlling circuits and stepper motor driving circuits are designed. There
APA, Harvard, Vancouver, ISO, and other styles
40

Sawada, Hidetaka, Masashi Watanabe, and Izuru Chiyo. "Ad Hoc Auto-Tuning of Aberrations Using High-Resolution STEM Images by Autocorrelation Function." Microscopy and Microanalysis 18, no. 4 (2012): 705–10. http://dx.doi.org/10.1017/s1431927612001304.

Full text
Abstract:
AbstractA method for measurement of the aberration status from high-resolution dark-field images is developed using scanning transmission electron microscopy (STEM), called the Segmented Image Autocorrelation function Matrix (SIAM). The method employs an autocorrelation function from the segmented area in the defocused STEM images from an aligned crystalline specimen to measure the defocus and twofold astigmatism for the probe-forming system. The values measured using this method can be fed directly back to the instrument by changing the strength of the stigmator and the objective lens of the
APA, Harvard, Vancouver, ISO, and other styles
41

Ponomarev, A. G., V. I. Miroshnichenko, and V. E. Storizhko. "Optimum collimator shape and maximum emittance for submicron focusing of ion beams. Determination of the probe-forming system resolution limit." Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 506, no. 1-2 (2003): 20–25. http://dx.doi.org/10.1016/s0168-9002(03)01380-9.

Full text
APA, Harvard, Vancouver, ISO, and other styles
42

Yang, Jun, Zsolt Paragi, Emanuele Nardini, et al. "The nearby extreme accretion and feedback system PDS 456: finding a complex radio-emitting nucleus." Monthly Notices of the Royal Astronomical Society 500, no. 2 (2020): 2620–26. http://dx.doi.org/10.1093/mnras/staa2445.

Full text
Abstract:
ABSTRACT When a black hole accretes close to the Eddington limit, the astrophysical jet is often accompanied by radiatively driven, wide-aperture and mildly relativistic winds. Powerful winds can produce significant non-thermal radio emission via shocks. Among the nearby critical accretion quasars, PDS 456 has a very massive black hole (about 1 billion solar masses), shows a significant star-forming activity (about 70 solar masses per year), and hosts exceptionally energetic X-ray winds (power up to 20 per cent of the Eddington luminosity). To probe the radio activity in this extreme accretion
APA, Harvard, Vancouver, ISO, and other styles
43

Pelletier, Stefan, Björn Benneke, Yayaati Chachan, et al. "CRIRES+ and ESPRESSO Reveal an Atmosphere Enriched in Volatiles Relative to Refractories on the Ultrahot Jupiter WASP-121b." Astronomical Journal 169, no. 1 (2024): 10. https://doi.org/10.3847/1538-3881/ad8b28.

Full text
Abstract:
Abstract One of the outstanding goals of the planetary science community is to measure the present-day atmospheric composition of planets and link this back to formation. As giant planets are formed by accreting gas, ices, and rocks, constraining the relative amounts of these components is critical to understand their formation and evolution. For most known planets, including the solar system giants, this is difficult as they reside in a temperature regime where only volatile elements (e.g., C, O) can be measured, while refractories (e.g., Fe, Ni) are condensed to deep layers of the atmosphere
APA, Harvard, Vancouver, ISO, and other styles
44

Yu, Yan, Xingjun Liu, Zhipeng Jiang, Cuiping Wang, Ryosuke Kainuma, and Kiyohito Ishida. "Thermodynamics and liquid phase separation in the Cu–Co–Nb ternary alloys." Journal of Materials Research 25, no. 9 (2010): 1706–17. http://dx.doi.org/10.1557/jmr.2010.0223.

Full text
Abstract:
This work first deals with the effect of Nb addition on the liquid phase separation in the Cu–Co system, which displays a metastable liquid miscibility gap. The isothermal sections at 800, 900, 1000, 1100, and 1200 °C in the Cu–Co–Nb system have been experimentally determined by optical microscopy, electron probe microanalysis, and x-ray diffraction on the equilibrated alloys, and the phase equilibria in the Cu–Co–Nb ternary system were thermodynamically assessed by using CALPHAD (Calculation of Phase Diagrams) method on the basis of the presently determined experimental data. Nb additions can
APA, Harvard, Vancouver, ISO, and other styles
45

Silcox, John. "The Emergence of Aberration Correctors for Electron Lenses." Microscopy Today 10, no. 3 (2002): 8–9. http://dx.doi.org/10.1017/s1551929500057977.

Full text
Abstract:
In 1936, Otto Scherzer published his famous theoretical paper on the correction of aberrations in round magnetic electron lenses. For fundamental reasons, the aberration coefficients are positive and to introduce negative corrections, the electron optical elements have to produce either charges or poles on the optic axis, or contain a mirror or be a multipole system. In 1997, three papers appeared with actual demonstrations of the correction of aberrations in imaging lenses, probe forming lenses and electron mirrors. It took almost two thirds of a century for this seemingly straightforward dev
APA, Harvard, Vancouver, ISO, and other styles
46

Löffler, Stefan, Thomas Schachinger, Peter Hartel, et al. "A quantum logic gate for free electrons." Quantum 7 (July 11, 2023): 1050. http://dx.doi.org/10.22331/q-2023-07-11-1050.

Full text
Abstract:
The topological charge m of vortex electrons spans an infinite-dimensional Hilbert space. Selecting a two-dimensional subspace spanned by m=&amp;#x00B1;1, a beam electron in a transmission electron microscope (TEM) can be considered as a quantum bit (qubit) freely propagating in the column. A combination of electron optical quadrupole lenses can serve as a universal device to manipulate such qubits at the experimenter's discretion. We set up a TEM probe forming lens system as a quantum gate and demonstrate its action numerically and experimentally. High-end TEMs with aberration correctors are
APA, Harvard, Vancouver, ISO, and other styles
47

Ueno, Yuko, and Kazuaki Furukawa. "On-Chip FRET Graphene Aptasensor." International Journal of Automation Technology 12, no. 1 (2018): 37–44. http://dx.doi.org/10.20965/ijat.2018.p0037.

Full text
Abstract:
We review the recent advances in the use of our originally developed on-chip graphene aptasensor to detect biologically important proteins, such as cancer markers. The detection mechanism, based on fluorescence resonance energy transfer (FRET), occurs at a graphene–biomolecule interface. In our system, the graphene surface is modified with a pyrene–aptamer–dye probe. Pyrene functions as a linker to the graphene surface, the aptamer as a probe for selective protein recognition, and the dye as a fluorescence detection tag. Here, graphene behaves simultaneously as both an efficient acceptor for F
APA, Harvard, Vancouver, ISO, and other styles
48

Dou, Yanxin, David N. Jamieson, Jianli Liu, and Liyi Li. "A high excitation magnetic quadrupole lens quadruplet incorporating a single octupole lens for a low spherical aberration probe forming lens system." Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms 419 (March 2018): 49–54. http://dx.doi.org/10.1016/j.nimb.2018.02.001.

Full text
APA, Harvard, Vancouver, ISO, and other styles
49

Krivanek, Ondrej L., Jonathan P. Ursin, Neil J. Bacon, et al. "High-energy-resolution monochromator for aberration-corrected scanning transmission electron microscopy/electron energy-loss spectroscopy." Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences 367, no. 1903 (2009): 3683–97. http://dx.doi.org/10.1098/rsta.2009.0087.

Full text
Abstract:
An all-magnetic monochromator/spectrometer system for sub-30 meV energy-resolution electron energy-loss spectroscopy in the scanning transmission electron microscope is described. It will link the energy being selected by the monochromator to the energy being analysed by the spectrometer, without resorting to decelerating the electron beam. This will allow it to attain spectral energy stability comparable to systems using monochromators and spectrometers that are raised to near the high voltage of the instrument. It will also be able to correct the chromatic aberration of the probe-forming col
APA, Harvard, Vancouver, ISO, and other styles
50

Borkovits, T., E. Forgács-Dajka, and S. A. Rappaport. "Third-body perturbed apsidal motion in eclipsing binaries." EAS Publications Series 82 (2019): 99–106. http://dx.doi.org/10.1051/eas/1982010.

Full text
Abstract:
Tidally forced apsidal motion in eccentric eclipsing binaries is a key observable of stellar structure studies, and may serve as important probe for different tidal dissipation theories. There are, however, alternative physical processes which result in additional contributions to the observed apsidal motion. Here we mainly concentrate on the perturbing effect of a third, distant stellar companion, forming a hierarchical triple system with the eclipsing pair. First we discuss the mathematical form of the combined third body and tidally forced apsidal motions, and its observational aspects. The
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!