Dissertations / Theses on the topic 'Punching Shear'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the top 50 dissertations / theses for your research on the topic 'Punching Shear.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.
Lyčka, Lukáš. "Punching Shear of Flat Slabs." Doctoral thesis, Vysoké učení technické v Brně. Fakulta stavební, 2019. http://www.nusl.cz/ntk/nusl-408019.
Full textShao, Xiao-yun. "Punching shear strength of reinforced concrete slab." Thesis, University of Ottawa (Canada), 1993. http://hdl.handle.net/10393/10727.
Full textHabibi, Farshad. "Post-punching shear response of two-way slabs." Thesis, McGill University, 2012. http://digitool.Library.McGill.CA:80/R/?func=dbin-jump-full&object_id=110632.
Full textCette thèse examine le comportement après poinçonnement des raccords dalle-colonne en béton armé dans le but de fournir le renforcement adéquat pour assurer l'intégrité structurale. Les résultats d'essais sur sept raccords dalle-colonne intérieurs sont présentés. L'étude portait sur les effets de l'épaisseur de la dalle, de la longueur des barres d'armature pour l'intégrité structurale, de la distribution de l'armature d'intégrité structurale dans les dalles avec colonnes rectangulaires et sur le placement de l'armature d'intégrité structurale dans les dalles avec des goussets. Les résultats de cette série d'essai et ceux d'autres chercheurs ont été comparés aux prévisions des équations de calcul de la norme CSA A23.3-04 pour le cisaillement par poinçonnement et la résistance après poinçonnement. Les résultats des essais montrent que la clause d'armature d'intégrité structurale selon les exigences de la norme CSA A23.3-04 produit une résistance importante après poinçonnement; les équations de calcul ont également fourni une estimation raisonnable de cette résistance. De plus, un modèle analytique permettant de prédire la réponse post-poinçonnement des connexions dalle-poteau est présenté. Ce modèle tient compte de la contribution de chaque lit d'armatures supérieures et chaque lit d'armature d'intégrité structurale. Cette contribution des deux lits d'armature est dictée par trois modes de rupture : rupture des armatures, rupture tronconique du béton et rupture par défaut d'ancrage des armatures. Les prédictions du modèle sont comparées aux résultats expérimentaux et aux résultats obtenus à l'aide de la méthode de dimensionnement de la norme CSA. La corrélation entre les prédictions de la méthode et les résultats expérimentaux est excellente.
Kennedy, Brian Wayne. "Punching shear of high-strength concrete slabs with perforations." Thesis, National Library of Canada = Bibliothèque nationale du Canada, 1997. http://www.collectionscanada.ca/obj/s4/f2/dsk2/ftp04/mq21178.pdf.
Full textXiang, Zhen Xian. "Punching shear strength of waffle slabs at internal columns." Thesis, University of Leeds, 1993. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.367299.
Full textHarris, Devin K. "Characterization of Punching Shear Capacity of Thin Uhpc Plates." Thesis, Virginia Tech, 2004. http://hdl.handle.net/10919/36366.
Full textMaster of Science
Aalto, Jonatan, and Elisabeth Neuman. "Comparison of Punching Shear Design Provisions for Flat Slabs." Thesis, KTH, Betongbyggnad, 2017. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-215631.
Full textTazaly, Zeinab. "Punching Shear Capacity of Fibre Reinforced Concrete Slabs with Conventional Reinforcement : Computational analysis of punching models." Thesis, KTH, Bro- och stålbyggnad, 2012. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-118825.
Full textLi, Kevin Ka Lun 1975. "Influence of size on punching shear strength of concrete slabs." Thesis, McGill University, 2000. http://digitool.Library.McGill.CA:80/R/?func=dbin-jump-full&object_id=30259.
Full textTest results obtained from this experimental program are compared with the punching shear predictions of the Canadian CSA A23.3-94 Standard, the American ACI 318-95 Code, the British BS 8110-85 Standard and the European CEB-FIP 1990 Model Code. Predictions were also made using computer program "Response 2000", assuming an equivalent beam analogy to represent the slab. It is concluded that the shear design of slabs, according to the current Canadian and American codes, can be unconservative under certain conditions, particularity for thick slabs. It is recommended that the punching shear expressions of the CSA Standard and the ACI Code be modified to take into account the "size effect" on the punching shear strength of slabs.
Li, Kevin Ka Lun. "Influence of size on punching shear strength of concrete slabs." Thesis, National Library of Canada = Bibliothèque nationale du Canada, 2000. http://www.collectionscanada.ca/obj/s4/f2/dsk1/tape4/PQDD_0033/MQ64235.pdf.
Full textHussein, Ahmad Fikri. "Punching shear strength at edge columns in ribbed flat slabs." Thesis, University of Leeds, 1994. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.367699.
Full textGomes, Ronaldo Barros. "Punching resistance of reinforced concrete flat slabs with shear reinforcement." Thesis, University of Westminster, 1991. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.303158.
Full textDiangha, Maurice Nkinyam Boh. "Punching shear modes of failure in impacted reinforced concrete beams." Thesis, University of Sheffield, 1995. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.245559.
Full textKuang, Jun Shang. "Punching shear failure of concrete slabs with compressive membrane action." Thesis, University of Cambridge, 1991. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.240241.
Full textSmith, Holly Kate Mcleod. "Punching shear of flat reinforced-concrete slabs under fire conditions." Thesis, University of Edinburgh, 2016. http://hdl.handle.net/1842/20962.
Full textSalim, Wijaya. "Punching shear failure in reinforced concrete slabs with membrane restraint." Thesis, University of Bristol, 2006. http://hdl.handle.net/1983/e2a8f32a-0fc2-40ee-8183-a9100122e429.
Full textKamaraldin, Khaled. "Punching shear and moment transfer in reinforced concrete flat slabs." Thesis, University of Westminster, 1990. https://westminsterresearch.westminster.ac.uk/item/94vwq/punching-shear-and-moment-transfer-in-reinforced-concrete-flat-slabs.
Full textThuresson, Sofia. "Parametric optimization of reinforced concrete slabs subjected to punching shear." Thesis, KTH, Betongbyggnad, 2020. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-279466.
Full textJust nu utvecklas Byggbranschen mot mer automatiserade och optimerade processer i projektdesignfasen. Denna utveckling beror till stor del på teknikutveckling i form av bättre datorprogram och tillgänglighet för dessa. Traditionellt sett löses komplexa konstruktionsproblem med hjälp av tidskrävande och storskaliga beräkningar, vilka sedan resulterar i ett begränsat antal utvärderade lösningar. Kvalitets lösningar bygger då på teknisk erfarenhet, antaganden och tidigare kunskaper inom ämnet.Användning av parametrisk design inom ett konstruktionsproblem är ett sätt att hantera komplexa lösningar. Dess metod avgränsar varje problem ner till ett antal lösbara parametrar, vilket gör att strukturen kan kontrolleras och rekombineras för att uppnå en optimal lösning.Denna avhandling introducerar begreppet parametrisk design och optimering i konstruktionsteknik, den förklarar hur programvaran fungerar och presenterar en fallstudie som genomförts för att utvärdera resultatet. I denna avhandling byggdes en parametrisk modell med hjälp av programvaran Dynamo för att hantera en designprocess av ett vanligt konstruktionsproblem. Det strukturella problemet som undersökts är en armerad betongplatta som stöds av en mittpelare, utsatt för genomstansning. Resultaten används för att utvärdera om en bättre design med avseende på materialanvändning har uppnåtts. Minimering av materialanvändning anses vara en bra parameter att undersöka eftersom det ger lägre kostnader och/eller lägre miljöpåverkan, detta undersöks under förutsättning att konstruktionens hållfasthet bibehålls. En parametrisk modell gör det möjligt för användaren att enkelt modifiera en konstruktionslösning med avseende på olika parametrar. Detta gör det till det perfekta verktyget att tillämpa en optimeringsprocess på.Syftet med denna avhandling var att hitta ett mer effektivt sätt att lösa ett komplext problem och att multiplicera antalet lösningar och utvärderingar av problemet jämfört med en mer konventionell metod. Fokus var att utveckla en parametrisk modell av en armerad betongplatta utsatt för genomstansning, som kommer att kunna genomföra optimering med avseende på tid som spenderas på projektet och därmed också kostnaden för konstruktionen och miljöpåverkan.Resultatet av denna fallstudie tyder på att det finns en stor möjlighet till kostnadsbesparingar och anses därför vara ett mycket hjälpsamt verktyg för en konstruktör. Resultatet visade flera lösningar som uppfyllde de konstruktionsmässiga kraven samtidigt som de gav en lägre materialanvändning tack vare optimeringen. Många lösningar tillhandahölls och utvärderades utöver vad som kunde ha gjorts i ett projekt med en konventionell metod. En parametrisk strategi kommer att hjälpa ingenjören att optimera lösningen för en konstruktion av denna typ.
Kallage, Mahmoud Rezai. "Punching shear strength of continuous post-tensioned concrete flat plate." Thesis, University of Ottawa (Canada), 1993. http://hdl.handle.net/10393/6605.
Full textMegally, Sami Hanna. "Punching shear resistance of concrete slabs to gravity and earthquake forces." Thesis, National Library of Canada = Bibliothèque nationale du Canada, 1998. http://www.collectionscanada.ca/obj/s4/f2/dsk2/tape17/PQDD_0008/NQ34686.pdf.
Full textSha'at, Emad. "Punching shear strength of reinforced concrete flat slabs at edge columns." Thesis, Queen's University Belfast, 1994. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.261880.
Full textAbdullah, Ahmad Mahmoud. "Analysis of repaired/strengthened R.C. structures using composite materials : punching shear." Thesis, University of Manchester, 2011. https://www.research.manchester.ac.uk/portal/en/theses/analysis-of-repairedstrengthened-rc-structures-using-composite-materials-punching-shear(6fd3f27c-ef35-4996-9707-09187ad10e9f).html.
Full textZamani, Zavieh Shahram. "Punching shear strength of edge column connections of rectangular flat plates." Thesis, University of Ottawa (Canada), 2003. http://hdl.handle.net/10393/26550.
Full textAl-Quraishi, Hussein Abbas Azeez [Verfasser]. "Punching Shear Behavior of UHPC Flat Slabs / Hussein Abbas Azeez Al-Quraishi." Kassel : Universitätsbibliothek Kassel, 2014. http://d-nb.info/1060472589/34.
Full textFong, Dickson Wen Jing. "Punching shear in waffle slabs in the presence of biaxial moment transfer." Thesis, University of Nottingham, 2018. http://eprints.nottingham.ac.uk/51640/.
Full textAl, Ajami Abdulhamid. "Punching shear of concrete flat slabs reinforced with fibre reinforced polymer bars." Thesis, University of Bradford, 2018. http://hdl.handle.net/10454/16864.
Full textJalal, Pasha, and Jose Andres Perez. "Punching shear in concrete flat slabs supported on slender edge steel columns." Thesis, KTH, Betongbyggnad, 2020. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-278546.
Full textGenomstansning är en brottmekanism orsakad av koncentrerade laster, vilket skapar ett sprickmönster i likhet med en konfrom ellet en bit av paj som börjar från den övre ytan av plattan och förlängs nedåt. När den totala skjuvkraften är större än skjuvmotståndet i plattan , kan det så småningom leda till ett genomstansningsbrott. Det kan visualiseras som att pelaren stansar eller slår igenom plattan. Genomstansning är ett mycket sprött brott och inträffar helt plötsligt. Det antas att plattan utsätts för negativt moment ovanför pelaren i båda riktningarna, d.v.s såväl parallellt som vinkelrät mot den fria kanten. Icke-linjära finita elementanalyser (NLFEA) har använts för att studera sprickbildnings och brottmekanismen för den förstärkta plattan. Det är en platta över kantstödet utan någon fast inspänd styvhet, därför simuleras skjuvmekanismen för plattan över en slank stålpelare i denna studie. Analyserna har utförts med programvaran ATENA 3D Engineering som utvecklats av Červenka Consulting. Eftersom hänsyn har tagits till symmetrin över en kantpelare har endast halva tvärsnittet modellerats, med en symmetrilinje som går vertikalt genom plattan och pelaren. Det kan sammanfattas att brottet som påträffas runt pelaren har en konisk form med ett sprickamönster som liknar de som påträffas vid genomstansning. Det är dock viktigt att notera att detta brott inte orsakats av klassisk genomstansning, utan istället på grund av skjuvsprickor som utvecklast runt pelaren i båda riktningarna, såväl parallellt som vinkelrät mot den fria kanten. Som det tidigare nämnts ovanför börjar sprickan vid genomstansning från plattans övre yta och förlängs nedåt diagonalt mot bottenplattan och intill pelaren. Sprickmönstret i remsan vinkelrät mot den fria kanten i alla tre modellerna (C1, C2 och C3) initierar dock från botten och sprids uppåt. Slutsatsen kan dras att längdminskningen av c-stängernas underben minskade skjuvhållfastheten hos betongplattan runt pelaren. Anledningen till detta beror på en minskning av maximal toppbelastning när c-stängernas underben reducerades. Följaktligen leder detta till en minskning av skjuvhållfastheten och ett tidigare brott, där den inre spännvidden inte kunda ta ytterligare belastningar som kunde ha lett till större nedböjningar.
Pettigrew, Christopher S. "Flexural, Shear, and Punching Shear Capacity of Three 48-Year-Old Prestressed Lightweight Concrete Double-Tee Bridge Girders." DigitalCommons@USU, 2014. https://digitalcommons.usu.edu/etd/3852.
Full textZorlu, Merve. "Evaluation Of Punching Shear Strength Design And Modelling Approaches For Slab-column Connections." Master's thesis, METU, 2012. http://etd.lib.metu.edu.tr/upload/12614889/index.pdf.
Full textŠalna, Remigijus. "Influence of steel fibers on punching shear strength of beamless reinforced concrete slabs." Doctoral thesis, Lithuanian Academic Libraries Network (LABT), 2008. http://vddb.library.lt/obj/LT-eLABa-0001:E.02~2008~D_20081119_134617-00531.
Full textDisertacijoje nagrinėjama dispersinio armavimo įtaka gelžbetoninių besijinių perdangos plokščių praspaudimo stipriui. Tyrimams buvo naudota literatūroje pateikiamų praspaudimo bei kompozitinių medžiagų stiprio bei deformacijų skaičiavimo modelių analizė. Taip pat atlikti realių matmenų eksperimentiniai plokščių praspaudimo tyrimai. Disertacijos darbo tikslas – pasiūlyti praspaudimo stiprio skaičiavimo modelį, leidžiantį įvertinti dispersinės armatūros tipą, jos stiprį, skirtingas inkaravimosi ir geometrines savybes bei dispersiškai armuotame betone pasireiškiančias plastines deformacijas. Siekiant šio tikslo buvo sprendžiami tokie uždaviniai: atlikta praspaudimo skaičiavimo metodų bei esamų praspaudimo modelių įtempių ir deformacijų būvio analizė, dispersiškai armuoto betono stiprio bei deformacijų esamų modelių ir metodų analizė, atlikti eksperimentiniai tyrimai modeliui patikrinti. Disertaciją sudaro šeši skyriai. Paskutinysis iš jų – rezultatų apibendrinimas. Pirmajame (įvadiniame) skyriuje nagrinėjamas problemos aktualumas, formuluojamas darbo tikslas ir uždaviniai, aprašomas mokslinis darbo naujumas, pristatomi autoriaus pranešimai bei publikacijos, disertacijos struktūra. Antrasis skyrius skirtas praspaudimo skaičiavimo metodų ir modelių analizei. Jo pabaigoje formuluojami disertacijos uždaviniai. Trečiajame skyriuje teoriškai nagrinėjamos dispersiškai armuoto betono stiprio ir deformacinės savybės. Atliktus analizę pasiūlytas dispersiškai armuoto betono stiprio ir... [toliau žr. visą tekstą]
Ngekpe, B. E. "Punching shear failure of reinforced concrete flat slabs supported on steel edge column." Thesis, Coventry University, 2016. http://curve.coventry.ac.uk/open/items/5f0f9112-1838-448f-a245-cacc0bc3a9f5/1.
Full textGrira, Mongi. "A critical review of the symmetric punching shear of reinforced concrete flat slabs." Thesis, University of Ottawa (Canada), 1990. http://hdl.handle.net/10393/6038.
Full textSudarsana, I. Ketut. "Punching shear in edge and corner column slab connections of flat plate structures." Thesis, University of Ottawa (Canada), 2001. http://hdl.handle.net/10393/6326.
Full textZhang, Xuesong, and n/a. "Punching Shear Failure Analysis of Reinforced Concrete Flat Plates Using Simplified Ust Failure Criterion." Griffith University. School of Engineering, 2003. http://www4.gu.edu.au:8080/adt-root/public/adt-QGU20051104.153239.
Full textBono, Matthew P. (Matthew Paul). "Tilt-up concrete panels : an investigation of flexural stresses and punching shear during lifting." Thesis, Massachusetts Institute of Technology, 2011. http://hdl.handle.net/1721.1/66823.
Full textCataloged from PDF version of thesis.
Includes bibliographical references (p. 75).
Tilt-up construction is becoming more popular in the United States due to its ease of construction, reliability, and relatively low construction and maintenance costs. In its most typical form, a concrete panel is cast on the ground. After the concrete sets and has reached a prescribed compressive or flexural strength, a crane lifts the panel off the ground and hoists it into place. The flexural stresses during liftoff are often times greater than those corresponding to service loads. Concentrations of high shear stress and the associated punching shear in the vicinity of the pick points could result in pullout. For these reasons, it is particularly important to design the concrete and steel reinforcement to handle the flexural and shear stresses associated with panel erection. This thesis investigates the flexural stresses and punching shear of a concrete panel designed for tilt-up. Finite element models confirm static hand calculations, and experimental results indicate that these models appropriately predicted erection stresses. The acceptability of the design provided is confirmed.
by Matthew P. Bono.
M.Eng.
Vosoughian, Saeed. "The effect of pre-stressing location on punching shear capacity of concrete flat slabs." Thesis, KTH, Betongbyggnad, 2019. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-263243.
Full textElGendy, Mohammed. "Punching shear behaviour of slab-column edge connections reinforced with fibre-reinforced polymer (FRP) composite bars." Canadian Society of Civil Engineering, 2014. http://hdl.handle.net/1993/24092.
Full textFernández, Sánchez Pablo Gonzalo. "Study on the shear and punching-shear strength of reinforced concrete slabs subjected to point loads and in-plane tensile forces." Doctoral thesis, Universitat Politècnica de Catalunya, 2021. http://hdl.handle.net/10803/673351.
Full textLos elementos de hormigón armado, especialmente cuando están sometidos a la acción de cargas puntuales, pueden alcanzar su resistencia última a esfuerzo cortante, lo cual limita su capacidad para deformarse y resistir valores de carga mayores. Este es un modo de fallo frágil y repentino, por lo que debe ser evitado. Así pues, es importante seguir investigando y comprender la naturaleza de la respuesta de vigas y losas de hormigón armado ante solicitaciones de este tipo, sobre todo cuando no están provistas de armadura de cortante. A pesar de la gran cantidad de campañas experimentales llevadas a cabo desde principios del siglo XX, el comportamiento a cortante y punzonamiento de los elementos estructurales de hormigón armado no está todavía del todo claro. La compleja cinemática y la diferente contribución de los mecanismos resistentes ampliamente aceptados, la cual depende, entre otros factores, del nivel de carga y de la geometría de los especímenes, son parte de esas incertidumbres que han provocado la falta de consenso que existe actualmente dentro del campo de la ingeniería estructural. En este contexto, esta tesis se centra en el comportamiento a cortante de losas de hormigón armado sin armadura de cortante sometidas a la acción de cargas puntuales. Por un lado, parte del trabajo realizado durante esta investigación está orientado al cortante en losas unidireccionales apoyadas sobre apoyos lineales. Gracias a todas las campañas experimentales realizadas en las últimas dos décadas, una significativa base de datos de resultados experimentales se encuentra disponible en la literatura, lo que ha permitido desarrollar y verificar un nuevo modelo mecánico para predecir la resistencia última a cortante de este tipo de elementos. Dicho modelo tiene en cuenta un número importante de variables involucradas en el fenómeno y es aplicable a losas simplemente apoyadas, en ménsula, y apoyadas en apoyos con restricción parcial al giro. El modelo se ha dividido en dos sub-modelos para facilitar su desarrollo. Uno para cargas aplicadas cerca de los apoyos, donde la transmisión directa de la carga al apoyo juega un papel importante, y un segundo para cargas aplicadas lejos de los apoyos, en donde se asume que la posibilidad del fallo por cortante coexiste con la posibilidad de un fallo local por punzonamiento. Por otro lado, la segunda parte de la investigación está focalizada en el comportamiento a cortante de losas de hormigón armado sometidas simultáneamente a la acción de cargas puntuales y tracciones en su plano. Este caso de carga no ha sido demasiado investigado a lo largo de las últimas décadas, y con la intención de contribuir a comprender esta compleja interacción, el modelo mecánico recientemente desarrollado en la UPC, para la predicción de la resistencia a punzonamiento en losas bidireccionales, ha sido extendido a este caso particular de cargas y validado con los resultados de campañas experimentales disponibles en la literatura y el conjunto de ensayos realizados como parte de esta investigación para el caso particular de tracciones unidireccionales. Adicionalmente, el efecto de las tracciones transversales en el plano en la resistencia a cortante de losas unidireccionales también ha sido estudiado experimentalmente. Esta combinación de cargas no ha sido apenas investigada y un nuevo grupo de ensayos experimentales puede contribuir a comprender el comportamiento global de este tipo de elementos ante este caso particular de carga.
Enginyeria de la construcció
Schreiber, Sascha K. "Punching shear capacity of slab-column connections with steel-fibre reinforcement under lateral cyclic loading." Thesis, National Library of Canada = Bibliothèque nationale du Canada, 2001. http://www.collectionscanada.ca/obj/s4/f2/dsk3/ftp04/MQ60493.pdf.
Full textPei, Shuangxi. "An investigation into the punching shear failure in R.C. waffle slabs subjected to concentrated load." Thesis, University of Abertay Dundee, 1994. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.240614.
Full textSchmidt, Philipp [Verfasser], Josef [Akademischer Betreuer] Hegger, and Jürgen [Akademischer Betreuer] Feix. "Punching in shear-reinforced flat slabs and column bases / Philipp Schmidt ; Josef Hegger, Jürgen Feix." Aachen : Universitätsbibliothek der RWTH Aachen, 2020. http://d-nb.info/1227993129/34.
Full textSamad, Shahab. "Engineering properties of binary cement concretes and their effect on punching shear of flat slabs." Thesis, Kingston University, 2013. http://eprints.kingston.ac.uk/26572/.
Full textHassan, Mohamed Ashour Wardany. "Punching shear behaviour of concrete two-way slabs reinforced with glass fiber-reinforced polymer (GFRP) bars." Thèse, Université de Sherbrooke, 2013. http://hdl.handle.net/11143/6129.
Full textLim, Boon Tiong. "Punching shear capacity of flat slab-column junctions (a study by 3-D non-linear finite element analysis)." Thesis, University of Glasgow, 1997. http://theses.gla.ac.uk/1708/.
Full textLabib, Wafa Abdelmajeed. "An experimental study and finite analysis of punching shear failure in steel fibre-reinforced concrete ground-suspended floor slabs." Thesis, Liverpool John Moores University, 2008. http://researchonline.ljmu.ac.uk/5893/.
Full textSilva, Carolina Ribeiro da. "Punção em lajes de concreto armado com furo e transferência de momento: comparação de normas." Universidade de São Paulo, 2017. http://www.teses.usp.br/teses/disponiveis/3/3144/tde-12032018-085200/.
Full textThe increasing use of flat slabs (slabs without beams with or without drop panel) as a structural solution of buildings, justified by economic and constructive issues, has highlighted the importance of the study of these structural elements. The disadvantages of this structural system are associated with high stresses generated in the region near of the columns, causing the punching shear phenomenon. The current standards specify a resistant section for punching shear design, however, due mainly to the passage of hydraulic and electric installations through the floors, it is necessary to execute holes, in some cases very close to the boundaries of the columns, which reduces this section and the slab strength. Therefore, it is necessary to specify calculation models for that. The NBR 6118 has criteria for this problem, nonetheless it is old and needs to be modernized. Comparing experimental data from some researches, with the estimated ultimate loads for current standards (fib MC2010: 2013, EC2: 2004, ACI-318: 2014 and NBR 6118: 2014), this work had as objective to identify limitations of the standards studied and verify possible improvements. Based on the observed results, it was proposed a modification for NBR 6118: 2014 in the design of the punching shear of flat slabs with hole(s) near of the column, considering the moment caused by the eccentricity of the critical perimeter due to the presence of hole(s) in the slab.
Melges, José Luiz Pinheiro. "Punção em lajes: exemplos de cálculo e análise teórico-experimental." Universidade de São Paulo, 1995. http://www.teses.usp.br/teses/disponiveis/18/18134/tde-25042018-115908/.
Full textNowadays, some standards like CEB/90 and the Brazilian code basic text NB-1/94 (not approved yet) have presented some innovations for the punching shear strength. In this work, a comparative analysis is presented about the NB1-94 basic text recommendations and some presented by the CEB/90. Some differences are noted between the NB1-94 basic text and the CEB/90 recommendations relatives to corner and edge columns. The CEB/90 has a simplified treatment for these situations. lt is noted that, in opposition to the CEB/90, the NB1-94 basic text about punching shear strength does not mention an additional reinforcement to be placed at the free edges of the slab, to provide torsion strength, and neither have a limit value of 50 MPa for the concrete compressive strength. lt is also noted that the CEB/90 and the NB1-94 basic text do not have a recommendation for internal columns with bending moments acting on two different directions. lt is suggested that the NB1-94 basic text includes some expressions that can make its application easier and faster. After this analysis, some examples are presented with internal, edge and corner columns, with and without shear reinforcement, verified by the NB1-94 basic text, the EUROCODE N.2, the CEB/90 and the ACI 318/89 recommendations. Finally, a comparative analysis between some experimental results and those given by the codes is presented. The experimental results were related to some parameters like, for instance, the presence of shear reinforcement or the column sides ratio. lt is verified that the shear reinforcement utilization can give more resistance and ductility to the connection. Finally, it is noted that the observations about the comparison between the experimental results and the values given by the codes can just be taken like a behavior indication for the connections. For conclusive affirmations, more experimental analysis are necessary.
Kueres, Dominik [Verfasser], Josef [Akademischer Betreuer] Hegger, Boyan [Akademischer Betreuer] Mihaylov, and Robert [Akademischer Betreuer] Vollum. "Two-parameter kinematic theory for punching shear in reinforced concrete slabs / Dominik Alexander Kueres ; Josef Hegger, Boyan Mihaylov, Robert Vollum." Aachen : Universitätsbibliothek der RWTH Aachen, 2018. http://d-nb.info/1180731204/34.
Full textAntunes, Filipe. "Estudo da perfuração de chapas grossas de aço ASTM A-36." reponame:Biblioteca Digital de Teses e Dissertações da UFRGS, 2017. http://hdl.handle.net/10183/173781.
Full textThe present work studies the variation of the initial diameter and final diameter of a punched hole made in an ASTM A-36 steel sheet with 12.7 mm of thickness. Three different punches geometries are proposed and manufactured from AISI D2 and AISI S1 steel with initial diameter 20 mm and final diameter 22 mm. The punches were manufactured to carry out the punching and broaching process with feed penetrations (asf) of 0.2 mm, 0.5 mm and 1 mm. The main objective is to reduce the conicity of the punched holes currently through the conventional method. The clearance between punch and die (w) used were 3.1%, 7.8% and 15.7% of the thickness of the test plate respectively. To evaluate the performance of each tool, all punched holes were measured and tabulated. Among the results, it was observed that the punches with a broaching showed better values than the conventional ones in all analyzed parameters. The regions of shear (Zc) and region of abrupt rupture (Zr) also had a direct influence in function of the geometry used.
Holanda, Kristiane Mattar Accetti. "Análise dos mecanismos resistentes e das similaridades de efeitos da adição de fibras de aço na resistência e na ductilidade à punção de lajes-cogumelo e ao cisalhamento de vigas de concreto." Universidade de São Paulo, 2002. http://www.teses.usp.br/teses/disponiveis/18/18134/tde-08022003-170132/.
Full textOne of the main problems of flat slabs concerns the punching shear failure of the slab-column connection. This form of failure must be avoided, providing flat slabs with the best conditions for the development of yielding mechanisms of the flexural reinforcement before the occurrence of shear failure. The addition of steel fibers to concrete elements subjected to tangential stress provides performance improvement, by either the resistant capacity increase or the failure mode alteration. It is intended to contribute to the advance of the subject knowledge, by exploring aspects as the analysis of similarities of the steel fiber addition effects on both strength and ductility of flat slabs to punching shear with those observed in the shear of analogous prismatic beams. The cases approached include internal slab-column connections without shear reinforcement, and the variables investigated included concrete strength, fiber volume and type of steel fiber. From the experimental results, it was possible to verify that there exists a similarity of structural behavior between these two elements and the shear tests in prismatic beams can be used to get indicators to be utilized in punching shear tests of flat slabs. An adaptability analysis of the existing theoretical models on shear in beams and punching shear in flat slabs was carried out in order to consider the steel fibers addition effect on the concrete. Based on these models, quantitative criteria for the evaluation of both strength and ductility of the slab-column connections were established.