Academic literature on the topic 'Qualidade do ar interior'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Qualidade do ar interior.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Qualidade do ar interior"

1

Costa, Vitor Akira Uesugui, Cassiano Ricardo de Souza, Luciane Andrade Melo, and Driano Rezende. "QUALIDADE DO AR EM AMBIENTES HOSPITALARES:." Revista Científica FAEMA 10, no. 2 (May 27, 2020): 67–83. http://dx.doi.org/10.31072/rcf.v10i2.837.

Full text
Abstract:
O presente estudo apresenta informações referente aos aspectos científicos, normativos e legislativos da qualidade do ar no ambiente interno de unidades hospitalares, seguida de uma investigação empírica em uma unidade hospitalar na região da floresta amazônica, estado de Rondônia. O trabalho foi realizado em duas etapas, a primeira etapa consiste em apresentar revisão bibliográfica de artigos científicos, normas e leis sobre qualidade do ar em estabelecimentos de assistência à saúde, na segunda etapa foi caracterizada a realidade de uma unidade hospitalar do interior do Estado de Rondônia sobre o tema abordado. Por meio do presente trabalho foi possivel disponibilizar informações sobre a qualidade do ar interior e potenciais riscos em ambientes hospitalares, servindo de base a pesquisadores, projetistas, adminitradores, colaboradores e até mesmo pacientes, de modo a disponibilizar conhecimento de projetos, implantação, gerenciamento e riscos relacionados a sistemas de climatização em diferentes setores hospitalares, por fim, na investigação empírica foi comprovada a completa incompatibilidade com normas e legislações específicas, apresentando uma análise realista proposta para a adequação normativa e legislativa do estabelecimento.
APA, Harvard, Vancouver, ISO, and other styles
2

Campos, Flaviane De Morais, Rossean Golin, Frederico César Caixeta, Luciana Sanches, and Danila Soares Caixeta. "Avaliação Quanti-Qualitativa do Ar Interior de Uma Biblioteca Pública do Município de Cuiabá-MT." E&S Engineering and Science 6, no. 1 (April 1, 2017): 95. http://dx.doi.org/10.18607/es201747566.

Full text
Abstract:
A qualidade do ar interior tem ganhado especial atenção nas últimas décadas, devido ao elevado tempo de permanência dos ocupantes nesses ambientes e consequentemente maior exposição a poluentes patogênicos. Objetivou-se com essa pesquisa avaliar a qualidade microbiológica do ar interior de uma biblioteca situada no município de Cuiabá-MT, utilizando o Método de Sedimentação Espontânea e Impactação sobre meio de cultura sólido. Em suma, os resultados obtidos para temperatura e umidade, na maioria dos pontos amostrados e período de coleta, mostraram fora dos padrões estabelecidos pela legislação em vigência. Em relação a qualidade bacteriológica foi constatado que para ambas metodologias utilizadas, 97% dos isolados apresentaram-se como Gram positivas. Por outro lado, na contagem fúngica pode-se observar que para relação Interior/Exterior na maioria dos pontos amostrados houve crescimento superior ao recomendado. Dentre os diversos fungos isolados, foi constatada a presença de Aspergillussp. ePenicillium sp. Assim, em locais de aprendizagem e desenvolvimento intelectual, social e pessoal como a biblioteca, a necessidade da implantação de medidas de prevenção e proteção de todos os seus freqüentadores no que se refere a problemática da Qualidade do Ar Interior.
APA, Harvard, Vancouver, ISO, and other styles
3

Campos, Flaviane de Morais, Rossean Golin, Frederico César Caixeta, Luciana Sanches, and Danila Soares Caixeta. "Avaliação Quanti-Qualitativa do Ar Interior de Uma Biblioteca Pública do Município de Cuiabá-MT." E&S Engineering and Science 6, no. 1 (April 1, 2017): 95–105. http://dx.doi.org/10.18607/es201764756.

Full text
Abstract:
A qualidade do ar interior tem ganhado especial atenção nas últimas décadas, devido ao elevado tempo de permanência dos ocupantes nesses ambientes e consequentemente maior exposição a poluentes patogênicos. Objetivou-se com essa pesquisa avaliar a qualidade microbiológica do ar interior de uma biblioteca situada no município de Cuiabá-MT, utilizando o Método de Sedimentação Espontânea e Impactação sobre meio de cultura sólido. Em suma, os resultados obtidos para temperatura e umidade, na maioria dos pontos amostrados e período de coleta, mostraram fora dos padrões estabelecidos pela legislação em vigência. Em relação a qualidade bacteriológica foi constatado que para ambas metodologias utilizadas, 97% dos isolados apresentaram-se como Gram positivas. Por outro lado, na contagem fúngica pode-se observar que para relação Interior/Exterior na maioria dos pontos amostrados houve crescimento superior ao recomendado. Dentre os diversos fungos isolados, foi constatada a presença de Aspergillussp. ePenicillium sp. Assim, em locais de aprendizagem e desenvolvimento intelectual, social e pessoal como a biblioteca, a necessidade da implantação de medidas de prevenção e proteção de todos os seus freqüentadores no que se refere a problemática da Qualidade do Ar Interior.
APA, Harvard, Vancouver, ISO, and other styles
4

Fraga, Sílvia, Elisabete Ramos, Anabela Martins, Maria João Samúdio, Gabriela Silva, Joaquim Guedes, Eduardo Oliveira Fernandes, and Henrique Barros. "Qualidade do ar interior e sintomas respiratórios em escolas do Porto." Revista Portuguesa de Pneumologia 14, no. 4 (July 2008): 487–507. http://dx.doi.org/10.1016/s0873-2159(15)30254-3.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Gameiro da Silva, Manuel. "A Importância da Qualidade do Ar Interior na Pandemia de COVID-19." Acta Médica Portuguesa 34, no. 12 (December 2, 2021): 805. http://dx.doi.org/10.20344/amp.17437.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Fernandes, Samuel, Getúlio Igrejas, and Manuel Feliciano. "Monitorização e controlo de qualidade do ar interior em gabinetes de edifícios escolares." Revista de Ciências Agrárias 40, SP (2017): S274—S281. http://dx.doi.org/10.19084/rca16192.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Rosa, Paula de Freitas, Mônica Lopes Aguiar, and André Bernardo. "Avaliação da eliminação de bioaerossóis em filtros de malha modificados com nanopartículas de prata." Engenharia Sanitaria e Ambiental 21, no. 4 (December 2016): 747–52. http://dx.doi.org/10.1590/s1413-41522016153177.

Full text
Abstract:
RESUMO O monitoramento da qualidade do ar interior (QAI) vem ganhando cada vez mais atenção nas pesquisas atuais, no entanto existem poucos trabalhos relacionados ao desenvolvimento de técnicas para minimizar os efeitos da poluição do ar interior. O objetivo deste estudo foi modificar os tecidos de malha poliéster e viscose (PV) com nanopartículas de prata, a fim de usá-los em aparelhos de ar-condicionado. Para alcançar esse objetivo, tecidos foram modificados por imersão dos filtros nas suspensões de nanopartículas. Depois da secagem do filtro, a coleta de material particulado foi feita em um banheiro de uma instituição de ensino superior. Os resultados mostraram que os filtros impregnados com nanopartículas de prata foram capazes de reduzir significativamente a atividade de microrganismos presentes no material particulado no ar, encontrando valores entre 22 e 83%.
APA, Harvard, Vancouver, ISO, and other styles
8

Jurado, Sonia Regina, Maria Vigoneti Araújo Lima Armelin, Thais Carolina Bassler, Mara Cristina Ribeiro Furlan, Andrea Sanchez, and André Valério da Silva. "Qualidade do ar interior em hospitais, aeronaves, navios de cruzeiros e o risco de transmissão aérea pelo Coronavírus." Saúde Coletiva (Barueri), no. 53 (August 6, 2020): 2376–93. http://dx.doi.org/10.36489/saudecoletiva.2020v10i53p2376-2393.

Full text
Abstract:
Os vírus representam causa comum de doença infecciosa adquirida em ambientes interiores, pois são facilmente transmitidos, especialmente em ambientes lotados e mal ventilados. Recentemente, o mundo vem passando pela pandemia da Síndrome Respiratória Aguda Grave do Coronavírus 2 (SARS-CoV-2). Esse estudo objetivou verificar na literatura internacional o risco de transmissão do vírus por aerossóis em ambientes climatizados, como hospitais, aeronaves e navios de cruzeiro. Tratou-se de revisão integrativa da literatura. A questão norteadora desta revisão foi: O Coronavírus pode se propagar pelo ar interior de ambientes climatizados como hospitais, aeronaves e navios e representar risco de transmissão para os usuários desses ambientes? A literatura pesquisada revelou que os aerossóis virais podem comprometer a qualidade do ar de ambientes interiores e facilitar a transmissão da SARS-CoV-2. Portanto, mais pesquisas devem ser realizadas no sentido de corroborar esses achados e também são necessárias medidas urgentes para melhorar a limpeza e higienização desses ambientes, além da verificação da renovação e filtragem do ar interior em salas de isolamento em hospitais, aeronaves e navios de cruzeiro.
APA, Harvard, Vancouver, ISO, and other styles
9

Cavalcanti, André Marques, André Marques Cavalcanti filho, Gustavo Passos Fortes, Janaína Karla De Souza Neto, and Leydiana De Sousa Pereira. "Análise da qualidade do ar interno sob a abordagem da manutenção preditiva e da inovação." Exacta 13, no. 1 (August 25, 2015): 45–54. http://dx.doi.org/10.5585/exactaep.v13n1.5259.

Full text
Abstract:
A qualidade do ar em interiores tem influência direta no bem-estar das pessoas que ocupam ou transitam nesses locais. A climatização surge da necessidade em oferecer condições de conforto para seus ocupantes, bem como dispor de sistemas que os protejam de impurezas contidas no ar. Em alguns ambientes com climatização artificial, os ocupantes podem desenvolver enfermidades, como: fadiga, infecções, irritação nos olhos e mucosas, náuseas, tonturas etc. Estes sintomas caracterizam, segundo a OMS, a “Síndrome do Edifício Doente”. Este artigo, por uma metodologia descritiva e exploratória, trata da avaliação da qualidade do ar interior, indicando a manutenção preditiva e seus aspectos de inovação como minimizadores dos agentes causadores de enfermidades que podem desenvolver-se nesses ambientes. Para tal, analisaram-se dez clientes de uma empresa especializada em climatização. Como resultado, encontraram-se inconformidades em alguns aspectos analisados, possibilitando a confecção de um plano de ação para adequação aos parâmetros legais.
APA, Harvard, Vancouver, ISO, and other styles
10

Carvalho, Thayla Morandi Ridolfi de, Daniella Jorge de Moura, Zigomar Menezes de Souza, Gustavo Soares de Souza, and Leda Gobbo de Freitas Bueno. "Qualidade da cama e do ar em diferentes condições de alojamento de frangos de corte." Pesquisa Agropecuária Brasileira 46, no. 4 (April 2011): 351–61. http://dx.doi.org/10.1590/s0100-204x2011000400003.

Full text
Abstract:
O objetivo deste trabalho foi avaliar as condições iniciais de alojamento de aves, de um dia de idade, em termos da qualidade da cama de frango reutilizada e do ar, em aviários comerciais de produção com diferentes sistemas de ventilação mínima e tipologia, por meio de análise geoestatística. O experimento foi realizado em quatro aviários: Blue House I (T1) e Blue House II (T2), Dark House (T3) e Convencional (T4). As variáveis analisadas foram: pH, umidade, temperatura superficial e concentração de amônia, tendo-se coletado as amostras na altura dos frangos, em 80 pontos equidistantes no interior do pinteiro. A análise geoestatística auxiliou a identificação de pontos críticos no controle dos ambientes estudados. O manejo da ventilação mínima não é suficiente para garantir a qualidade do ar nos pinteiros. A cama reutilizada de casca de café e arroz (T1 e T2) apresenta melhor qualidade do que a cama reutilizada de maravalha fina (T3 e T4). O sistema de ventilação mínima, em T2 e T4, é o mais eficiente quanto à renovação do ar nos pinteiros.
APA, Harvard, Vancouver, ISO, and other styles
More sources

Dissertations / Theses on the topic "Qualidade do ar interior"

1

Silva, Sara Alexandre. "Modelação da qualidade do ar interior." Master's thesis, Universidade de Aveiro, 2016. http://hdl.handle.net/10773/18622.

Full text
Abstract:
Mestrado em Engenharia do Ambiente
O objetivo principal desta tese consiste em aprofundar o conhecimento sobre a qualidade do ar interior, através da aplicação de uma ferramenta numérica para o cálculo das concentrações de poluentes no ar interior. A utilização de um modelo numérico permitiu avaliar quantitativamente o impacto de diferentes medidas de melhoria da qualidade do ar interior, através da simulação de cenários. Neste trabalho, foi utilizado o modelo numérico de balanço de massa, CONTAM, para caracterizar a qualidade do ar interior em instituições de ensino, em termos das concentrações de dióxido de carbono, monóxido de carbono e material particulado. Os dois casos de estudo foram uma sala de aula da Escola Básica da Glória e um Gabinete do Departamento de Ambiente e Ordenamento da Universidade de Aveiro, ambos situados em Aveiro. Os resultados obtidos através da aplicação do modelo CONTAM foram comparados com valores medidos no decorrer de campanhas de monitorização. No caso da Escola Básica da Glória verificou-se uma boa concordância entre os valores simulados e medidos de dióxido de carbono e uma concordância razoável no que se refere ao monóxido de carbono. Relativamente ao material particulado, verifica-se que os valores simulados não conseguem refletir valores de pico medidos no interior da sala de aula. Atendendo aos valores obtidos no interior da sala, optou-se por estabelecer e simular vários cenários alternativos à situação base, com o objetivo de maximizar a qualidade do ar interior da sala. Nestes cenários, variaram-se os horários de abertura e permanência da porta e das janelas da sala de aula. Concluiu-se que o cenário que regista uma qualidade do ar interior mais favorável, isto é, que mantém os gases poluentes referidos com concentrações mais baixas, é aquele em que a porta era aberta pontualmente para entrada e saída dos alunos da sala e em que se manteve uma janela meio aberta durante todo o dia. Na aplicação do modelo ao gabinete do Departamento de Ambiente e Ordenamento da Universidade de Aveiro, conclui-se que o modelo é válido na simulação do dióxido de carbono. Não foram criados cenários de melhoria para o gabinete por se considerar que o comportamento dos seus utilizadores é eficaz na diminuição das concentrações de dióxido de carbono no ar interior. A partir desta tese é possível concluir que o modelo CONTAM pode ser utilizado na avaliação de cenários alternativos com o objetivo de maximizar a qualidade do ar interior em instituições de ensino.
The main objective of this thesis is to extend the knowledge of indoor air quality by using a numerical tool to calculate the concentrations of pollutants in indoor air. The application of a numerical model allowed to quantitatively assess the impact of several improvement measures, through the simulation of scenarios. In this work, the mass balance numerical model CONTAM was used to characterize the indoor air quality in two teaching institutions, in terms of concentration of carbon dioxide, carbon monoxide, and particulate matter. The chosen case studies were a classroom of the Escola Básica da Glória and an office of the Departamento de Ambiente e Ordenamento da Universidade de Aveiro, both located in Aveiro. The results of the CONTAM simulations were compared to measurements performed during monitoring campaigns. The results show a good agreement between the simulated and measured carbon dioxide concentrations and a reasonable agreement for carbon monoxide inside the classroom of Escola Básica da Glória. For particulate matter simulated values do not reflect the higher measured values. Taking into account the results in the case of the classroom, several alternative scenarios were simulated, having in mind the maximization of the indoor air quality. In these scenarios, the schedules of both the door and the windows were changed. The scenario promoting the best indoor air quality (i.e., the one that led to the lowest concentrations of carbon dioxide and carbon monoxide) is the one in which the door is only open to allow students to get in and out of the room, and the window is kept half-open during the whole day. Concerning the application of the model to the office, the model is valid for simulating carbon dioxide concentrations. No alternative scenarios were created for this case study, as it is believed that the regular behavior of its users effectively minimizes the concentration of carbon dioxide. This work led to the conclusion that CONTAM can be used to accurately numerically evaluate alternative scenarios that contribute to the maximization of the indoor air quality in teaching institutions.
APA, Harvard, Vancouver, ISO, and other styles
2

Marques, Liliana Rute Dias. "Qualidade do ar interior em instalações desportivas." Master's thesis, Universidade de Aveiro, 2013. http://hdl.handle.net/10773/12433.

Full text
Abstract:
A Qualidade do Ar Interior (QAI) tem vindo a despertar cada vez mais o interesse da comunidade científica, pelo facto das sociedades modernas passarem a grande maioria do seu dia em ambientes interiores, sendo o ar que respiramos um fator determinante na saúde e bem-estar do ser humano. Os indivíduos que praticam desporto estão em particular risco de inalar poluentes, não só porque durante a atividade desportiva estão sujeitos a maiores taxas de consumo de ar mas também ao facto de uma grande fração de ar ser inalada pela boca durante a prática de exercício físico. Atendendo à crescente preocupação com a QAI e ao maior ou menor risco de exposição dos indivíduos em recintos desportivos torna-se pertinente avaliar e caracterizar a qualidade do ar, área esta em que o conhecimento e estudos sobre a qualidade do ar são ainda escassos. O trabalho aqui apresentado teve como objetivo avaliar a qualidade do ar em recintos desportivos, tendo sido para o efeito realizado um estudo que recaiu sobre duas unidades desportivas com diferentes tipologias e práticas a eles associadas, fronton e ginásio, pertencentes à Universidade de Léon, Espanha. Cada local foi alvo de uma campanha de monitorização da QAI durante o mês de Julho de 2012 que envolveu a medição de parâmetros de conforto (temperatura, humidade relativa, CO2) e de poluentes gasosos (CO, COVs totais e compostos de carbonilo) e partículas (PM10) quer em termos de distribuição por tamanhos (distribuição numérica e volúmica/massa) quer das concentrações mássica e sua composição química (OC/EC, carbonatos e iões inorgânicos solúveis). As campanhas de monitorização da QAI nos dois recintos foram igualmente acompanhadas da monitorização da qualidade do ar exterior na sua vizinhança. A amostragem incluiu a monitorização em contínuo de parâmetros de temperatura, humidade relativa, CO2, CO, COVs e partículas, o uso de amostradores passivos para a recolha de NO2, carbonilos e COVs e a utilização de um amostrador de baixa caudal para a recolha de PM10. As taxas de ventilação mínimas recomendadas foram observadas nas duas instalações. As atividades de limpeza, no interior do fronton coincidiram com aumentos significativos de COVs e partículas. No exterior das instalações e no interior do fronton as concentrações de PM10 foram sempre inferiores a 50 μg m-3. No interior do ginásio foram registadas concentrações de PM10 de 150 μg m-3, associadas a processos de ressuspensão e ao uso de magnésia alba, um pó utilizado na prática de certos aparelhos desportivos. As elevadas concentrações de magnésio e carbonato evidenciam a importância da magnésia nos níveis de PM10 observados no ginásio. De igual modo as distribuições de partículas por tamanho demostraram um claro contributo do uso da magnésia e dos processos de ressuspenção, associados às atividades físicas, no aumento do número de partículas. O contributo de carbono total (OC e EC) nas PM10 foi cerca de 30%, nos dois espaços interiores.
The indoor air quality (IAQ) has been increasingly awaken the interest of the scientific community, because of modern societies spend the majority of their day indoors and the air we breathe is a crucial factor in the health and wellbeing of humans. Individuals who play sports are at particular risk to inhale pollutants, not only because during sport activities may be subject to higher rates of air consumption but also because a large percentage of air is inhaled through the mouth during physical exercise. Taking into account the growing concern about IAQ and the risk of exposure of individuals in sports arenas becomes relevant evaluate and characterize the air quality in this area which the knowledge and studies are scarce. The work presented here aims to evaluate the air quality in sport arenas, it have been carried out to study the effect in two sports facilities with different typologies and practices associated with them, fronton and gym, belonging to the University of León, Spain. Each place was the target of IAQ monitoring campaign during the month of July 2012 which involved comfort parameters measurement (temperature, relative humidity, CO2) and gaseous pollutants (CO, total VOCs and carbonyl compounds) and particles (PM10) and in terms of size distribution (number and density distribution / mass) and the mass concentrations and chemical composition (OC / EC, carbonates and soluble inorganic ions). The IAQ monitoring campaigns in the two places were also accompanied by monitoring of outdoor air quality in the neighborhood. The sampling tasks include continuous monitoring of temperature, relative humidity, CO2, CO, VOCs and particles the use of a passive sampler for collecting NO2 and VOCs carbonyls and using a low flow sampler for collecting PM10. The recommended minimum ventilation rates were observed in the two facilities. Cleaning activities inside the fronton coincided with significant increases in VOCs and particles. Outside and inside the fronton PM10 concentrations were always below 50 μg m-3. Inside the gym were registered PM10 concentrations of 150 μg m-3, connected to resuspension processes and magnesia alba, a powder used in the practice in some gymnastic equipment’s. High concentrations of magnesium and carbonate empathizes the importance of magnesia in PM10 levels observed in the gym. Similarly, the distribution of particles by size demonstrated a clear contribution from the use of magnesia and resuspension processes, associated with physical activities, in increasing the number of particles. The contribution to total carbon (OC and EC) in PM10 was about 30% in both inside spaces.
APA, Harvard, Vancouver, ISO, and other styles
3

Matos, Ema Maria Monteiro de. "Relatório profissional: qualidade do ar interior e certificação." Master's thesis, Universidade de Aveiro, 2012. http://hdl.handle.net/10773/9710.

Full text
Abstract:
Mestrado em Engenharia do Ambiente
Este relatório tem como objetivo apresentar o percurso académico e profissional da candidata, iniciado em 1980 com o ingresso na Universidade de Aveiro, dando especial ênfase ao percurso profissional e à atividade desenvolvida na área da qualidade do ar, nomeadamente a qualidade do ar interior. Inclui uma apresentação detalhada de todo o percurso profissional, abrangendo desde o trabalho desenvolvido no projeto de fim de curso, passando pelas funções desempenhadas em instituições estatais, como a Direção Regional de Ambiente do Centro e o Gabinete de Apoio Técnico de Águeda, às funções de coordenação da unidade de ambiente e laboratórios do Centro da Biomassa para a Energia, culminando na atual atividade de consultoria. No âmbito do tema de desenvolvimento selecionado é feita uma abordagem e enquadramento da qualidade do ar interior, sua influência na saúde humana e regulamentação aplicável. O relatório termina com uma análise da evolução da experiência profissional, evidenciando a sua relevância como atividade da especialidade do Mestrado em Engenharia do Ambiente.
This report aims to present the candidate’s academic and professional path which started in 1980 with the enrollment at the University of Aveiro, giving special emphasis to the professional career and the activity developed on the air quality area, namely the indoor air quality. It includes a detailed presentation of the entire professional career, from the work developed in the final graduation project, the duties carried out in state institutions such as the Regional Direction for the Environment and the Technical Support Office, to the coordination duties of the Biomass Centre for Energy’s environment and laboratories unit, culminating in the current consulting activity. An approach and framing of the indoor air quality, its influence on the human health and applicable regulations is done under the selected development topic. The report ends with an analysis of the evolution of the professional experience, highlighting its relevance as an activity of the specialty of the Master of Science Degree in Environmental Engineering.
APA, Harvard, Vancouver, ISO, and other styles
4

Fakhoury, Nícolas Alexandre. "Estudo da qualidade do ar interior em ambientes educacionais." Universidade de São Paulo, 2017. http://www.teses.usp.br/teses/disponiveis/3/3150/tde-11072017-135147/.

Full text
Abstract:
A Qualidade do Ambiente Interior (QAI) é um dos principais fatores que determina a funcionalidade, harmonia, conforto e produtividade em um edifício. A QAI afeta a saúde e o conforto dos ocupantes de um edifício, bem como a habilidade dos mesmos em realizar tarefas, influenciando diretamente na produtividade. Quando a QAI é boa, os ambientes se tornam lugares mais desejáveis para estar, trabalhar e aprender. O ambiente de escolas e universidades pode exercer um impacto significativo na saúde e no aprendizado de crianças e estudantes universitários. A limitação da entrada de poluentes e contaminantes, bem como o fornecimento da quantidade adequada de ar externo filtrado e limpo, melhoram o desempenho acadêmico dos estudantes e não atinge a saúde dos mesmos. Este trabalho apresenta medições de parâmetros físicos e químicos, CO2, PM2,5, PM10, temperatura de bulbo seco e umidade relativa, efetuadas em uma sala de aula do prédio de Engenharia Mecânica da Escola Politécnica da Universidade de São Paulo (EPUSP) os quais os estudantes e professores estavam sujeitos. As medidas foram tomadas no ambiente interno e externo a sala de aula, onde atividades teóricas e práticas eram realizadas. A vazão de ar externo, previamente filtrado, era variada para a redução dos contaminantes gerados internamente. Constatou-se que os particulados PM2,5 e PM10 atingiram concentrações críticas de 6 e 30 vezes maiores do que o limite proposto pelas normas vigentes, respectivamente, bem como a concentração de CO2 que atingiu 3 vezes o limite recomendado. Porém, observou-se que o aumento da vazão de ar externo em aproximadamente 2200 m³/h foi suficiente para a diminuição da concentração de PM10 em 50% nos primeiros 20 minutos. Apesar da diminuição da concentração, a vazão recomendada de ar externo por pessoa não foi suficiente para a concentração de material particulado atingir os limites aceitáveis. Por fim, apresenta-se uma proposta de projeto detalhado de dois sistemas independentes de tratamento de ar que permitirão a realização de experimentos e estudos sobre a QAI, podendo-se variar a vazão de ar externo e a classe de filtragem da recirculação e da tomada de ar externo para dois laboratórios do Departamento de Engenharia Mecânica da EPUSP, que podem dar sequência aos estudos deste trabalho.
The Indoor Environmental Quality (IEQ) is one of the main factors that determines the functionality, harmony, comfort and productivity in a building. The IEQ affects the health and comfort of the occupants of a building, as well as the ability of them to perform tasks, influencing directly in productivity. When IEQ is good, the environments become more desirable places to be in, work and learn. The indoor environment of schools and universities can have a significant impact on the health and learning of children and college students. The limitation of input of pollutants and contaminants, as well as providing the appropriate amount of filtered and clean outside air, improve the academic performance of students and does not affect the health of the same. This paper presents measurements of physical and chemical parameters, CO2, PM2,5, PM10, dry bulb temperature and relative humidity, made in a classroom of the Mechanical Engineering building of the Polytechnic School of the University of São Paulo (EPUSP) which students and teachers were subject. The measurements were taken in the internal and external environment of the classroom, where theoretical and practical activities were conducted. The flow of outside air, previously filtered, was varied for the reduction of contaminants generated internally. It was found that the particulate PM2,5 and PM10 achieved critical concentrations of 6 and 30 times greater than the limit proposed by the current standards, respectively, and that the concentration of CO2 reached 3 times the recommended limit. However, it was observed that increasing outside air flow of approximately 2200 m³/h was enough to decrease the concentration of PM10 in 50% at the first 20 minutes. Despite the decreased concentration, the recommended flow of outside air per person was not enough for the concentration of particulate matter reaches the acceptable limits. Finally, a detailed project proposal is presented of two independent air treatment systems that will allow performing experiments and studies on the IEQ, being able to vary the flow of outside air and, the filters of the recirculation and external air intake for two laboratories of the Department of Mechanical Engineering of EPUSP, that can follow the studies of this work.
APA, Harvard, Vancouver, ISO, and other styles
5

Teixeira, Ricardo Miguel Oliveira. "Simulação da qualidade do ar interior em ambiente escolar." Master's thesis, Universidade de Aveiro, 2012. http://hdl.handle.net/10773/10208.

Full text
Abstract:
Mestrado em Engenharia do Ambiente
A qualidade do ar interior (QAI) em salas de aula é um fator determinante na incidência e prevalência de doenças do foro respiratório dos utentes do espaço escolar (alunos, professores e funcionários), sendo particularmente relevante no caso de crianças e jovens. Com base neste problema, esta dissertação tem como principal objetivo avaliar qual a contribuição da poluição exterior para os níveis de QAI numa escola do concelho de Aveiro (Escola Básica nº 1 da Glória), recorrendo à aplicação do modelo IAQX (Simulation Tool Kit for Indoor Air Quality and Inhalation Exposure). Utilizaram-se como dados de entrada no modelo IAQX as concentrações exteriores de monóxido de carbono (CO) simuladas no modelo de qualidade do ar VADIS, obtendo-se dessa forma as concentrações interiores numa das salas de aulas da escola selecionada. A comparação destas com os valores medidos possibilitou, assim, aferir qual a contribuição do ar exterior para os níveis de QAI na Escola Básica nº 1 da Glória. Os resultados obtidos nesta dissertação demonstram que as concentrações exteriores de CO têm influência nas concentrações interiores da Escola Básica nº 1 da Glória. Os valores simulados com o modelo IAQX não são totalmente concordantes com os valores medidos no interior da sala de aula, o que pode ser explicado por fatores locais, tais como o fator humano (por exemplo, a abertura de janelas), ou por fatores relacionados com o escoamento e dispersão atmosférica. No entanto, tanto os valores medidos como os valores simulados da concentração interior de CO não ultrapassam o valor máximo para edifícios escolares estipulado no Decreto-Lei nº 79/2006, de 4 de abril. Apesar dos resultados revelarem que as concentrações interiores de CO não indicam uma má QAI na Escola Básica nº 1 da Glória, para garantir que a escola esteja a cumprir todos os padrões de uma boa QAI, é necessário analisar mais poluentes e parâmetros para além do CO.
The indoor air quality (IAQ) in classrooms is a key factor in the incidence and prevalence of respiratory diseases of the school users (students, teachers and staff), being particularly relevant for children and youth. Based on this problem, the main objective of this thesis is to evaluate the contribution of outdoor pollution to the IAQ levels in a school (Escola Básica nº 1 da Glória) of Aveiro town (Portugal), by applying the IAQX (Simulation Tool Kit for Indoor Air Quality and Inhalation Exposure) model. Using as input data the carbon monoxide (CO) outdoor concentrations simulated in the air quality VADIS model, the indoor concentrations in one of the classrooms of the selected school were obtained. The comparison of these with the measured values allowed the assessment of the contribution of outdoor air for IAQ levels in Escola Básica nº 1 da Glória. The results obtained in this work show that CO outdoor concentrations have influence on the indoor concentrations of Escola Básica nº 1 da Glória. The values simulated with the IAQX model inside the school classroom are not fully consistent with the measured values, which can be explained by local factors, such as the human factor (eg. the opening of windows), or by atmospheric flow/dispersion factors. However, both measured values and simulated values of CO indoor concentration do not exceed the maximum value to school buildings stipulated in Decreto-Lei nº 79/2006 of 4th April. Although the results reveal that CO indoor concentrations do not indicate a poor IAQ in Escola Básica nº 1 da Glória, to ensure that the school is fulfilling all the standards of a good IAQ, it is necessary to analyse more pollutants and parameters in addition to CO.
APA, Harvard, Vancouver, ISO, and other styles
6

Queirós, Fernando Manuel Oliveira. "Sistema pericial para gestão da qualidade do ar interior em edifícios." Master's thesis, Universidade de Aveiro, 2011. http://hdl.handle.net/10773/8152.

Full text
Abstract:
Mestrado em Engenharia Mecânica
O surgimento das chamadas “casas inteligentes” é um avanço fundamental para optimizar e potenciar a utilização dos edifícios. Os sistemas inteligentes revelam-se como ferramentas poderosas para a garantia de uma boa qualidade do ar interior nos edifícios, podendo garantir igualmente um ambiente confortável e eficiente. Tendo ainda em conta que grande parte dos edifícios existentes não possui sistemas de ventilação mecânica e que a má qualidade do ar interior nem sempre é perceptível pelos seus ocupantes, torna-se ainda mais evidente o elevado potencial deste tipo de sistemas nesta matéria. Através da monitorização das condições ambientais no interior e no exterior de um edifício, é proposto e desenvolvido nesta dissertação um sistema inteligente capaz de acessorar os seus ocupantes para uma gestão correcta das suas aberturas naturais, designadamente das janelas, procurando não apenas garantir a boa qualidade do ar interior, mas também elevados níveis de conforto térmico e baixo consumo energético. Este sistema é composto pelos equipamentos de monitorização do ar interior e exterior e por uma unidade central de processamento dos dados. No âmbito deste sistema, foi desenvolvida uma aplicação local e um Portal Web, responsáveis pelo processamento dos dados, através da aplicação de um modelo de decisão concebido para o efeito, e pela interacção do sistema com o utilizador. O software desenvolvido possui um interface simples e de fácil acesso, uma vez que se encontra disponibilizado online, de forma a tornar assídua a sua utilização. Para além das aplicações, a interacção com o utilizador é efectuada por intermédio de um alerta sonoro presente no interior do espaço. A análise paramétrica efectuada permite comprovar a elevada capacidade de resposta do modelo à alteração dos parâmetros relativos às condições a que se encontra o espaço a controlar. Desta forma, verifica-se que este apresenta versatilidade de resposta, independentemente das características do edifício, o que significa que tem potencial para ser utilizado em qualquer região, período do ano, tipo de edifício ou até mesmo em edifícios com ou sem climatização interior. O caso de estudo apresentado compara os resultados relativos às necessidades energéticas e à qualidade do ar interior entre o modelo desenvolvido e as situações em que a janela se encontra sempre aberta e fechada. Os resultados obtidos atestam que as necessidades energéticas do modelo aproximam-se bastante mais do caso em que a janela está fechada, revelando apenas um aumento de 20%, enquanto que a qualidade do ar interior média é significativamente melhor em relação a esse caso. Conclui-se portanto que existe um aproveitamento mais eficiente das taxas de fluxo de ar, com consequências muito positivas nas necessidades energéticas, comprovando o potencial da introdução de sistemas inteligentes na gestão da qualidade do ar interior.
The forthcoming of the “smart homes” is a crucial progress to optimize and potentiate the buildings use. Intelligent systems have emerged as powerful tools not only for ensuring the indoor air quality of the buildings, but also to ensure a comfortable and efficient environment. Taking into account that most of the existing buildings does not have mechanical ventilation systems and that poor indoor air quality is not always perceived by its occupants, it’s even more clear the high potential of these systems in this area. By monitoring the indoor air quality and the external environmental conditions of the building, it is proposed and developed in this thesis an intelligent system capable of guiding its occupants to an efficient management of its windows, not only to ensure a good indoor air quality, but also good levels of thermal comfort and low energy consumption. This system consists of equipment for monitoring indoor and outdoor air and a central processing unit of the data received by the equipment. Under this system, a local application and a Web portal were developed, with the purpose of processing the data, using a decision model designed for such matter, and interact with the user. The developed software has a simple and easy to access interface, as it is available online, in order to improve and potentiate its use. Apart from applications, user interaction is also done through an alert sound from the space monitored. The parametric analysis shows the high responsiveness of the model to changes of the parameters related with the conditions to which the controlled space is exposed. Thus, it’s visible the versatility of response of model, regardless of the characteristics of the building, which means it has the potential to be used in any region, time of year, type of building or even in buildings with or without inside air conditioning. The case study presented compares the results for the energy requirements and indoor air quality between the developed model and the situations in which the window is always opened and always closed. The results show that the energy requirements of the model are very close to the ones verified for the case where the window is closed, with only a 20% increase, while the average indoor air quality is significantly higher in relation to this case. Therefore it is concluded that there is a more efficient use of air flow rates, with very positive results in energy needs, which shows the potential of the introduction of the intelligent systems in the management of indoor air quality.
APA, Harvard, Vancouver, ISO, and other styles
7

Bernardes, Ângela Cristina da Cruz. "Análise dos métodos de auditoria à qualidade do ar interior: RSECE." Master's thesis, Universidade de Aveiro, 2009. http://hdl.handle.net/10773/663.

Full text
Abstract:
Mestrado em Sistemas Energéticos Sustentáveis
Em consequência da elevada permanência das pessoas em espaços interiores, actualmente estimado em cerca de 90% de tempo, e dos deficientes níveis de ventilação dos espaços em boa parte por questões energéticas, temse acentuado o problema da má Qualidade do Ambiente Interior (QAI). A preocupação de aliar o uso racional da energia à saúde dos ocupantes, surge recentemente em Portugal e apenas se tornou mais evidente com a aplicação do Regulamento dos Sistemas Energéticos de Climatização dos Edifícios (RSECE, 2006). A actual preocupação com a monitorização e melhoria da QAI levou à elaboração de diversos documentos e guias técnicos, cujo principal objectivo é fornecer linhas de orientação no processo de avaliação da QAI, nomeadamente na selecção dos métodos a utilizar. No entanto, e dada a diversidade e complexidade dos poluentes interiores, a indicação de métodos de referência que garantam uma avaliação eficaz e versátil enfrenta alguns desafios inerentes aos espaços interiores a avaliar e às próprias limitações dos métodos. Neste sentido efectuou-se uma análise exaustiva dos métodos de referência e equivalentes indicados pelo RSECE, levando a cabo uma pesquisa que incidiu sobre as principais vantagens, desvantagens e limitações dos mesmos. O resultado culminou num estudo resumo e análise comparativa entre os vários métodos seleccionados para cada parâmetro e poluente a ser auditado, e que pretende ser uma ferramenta de optimização do processo da auditoria. Através da análise aos guias técnicos foi ainda possível constatar que existem ainda algumas lacunas a preencher, sobretudo, nas metodologias adoptadas para realização das auditorias. Mas, de um modo geral, estes documentos caminham para uma versão capaz de responder aos objectivos do RSECE. ABSTRACT: A higher indoor occupation, currently estimated at around 90% of people’s time, and the poor space ventilation, mainly caused by energy issues, has accentuated the problem of the poor Indoor Environment Quality (IEQ). The rational use of energy concern combined with the occupants health is recent in Portugal and only became more evident with the implementation of the Regulation of Energy Systems for Buildings Acclimatization. (RSECE, 2006). The current IEQ monitoring and improvement concern has resulted into several papers and technical manuals, in order to provide IEQ evaluation guidelines and to define the methodology to be used in each case. However, due to the indoor pollutants diversity and complexity, the choice of an effective and versatile reference method faces several challenges nowadays, which are inherent to the spaces under evaluation and the own method constraints. An exhaustive analysis to the RSECE’s reference methodologies has been made, throughout the research of the main advantages, disadvantages and constraints of each one. This approach resulted in a summary and comparative analysis between the selected methods for each parameter and pollutant to be audited, and is capable to be used as an auditing process optimization tool. By the analysis of the technical guidelines it was possible to understand that there are still some gaps to fulfill, mainly the auditing chosen methodology. Nevertheless, these documents are becoming more capable to meet the RSECE policy objectives.
APA, Harvard, Vancouver, ISO, and other styles
8

Barraca, Carla Joana Neto. "Modelação da qualidade do ar interior em edifícios com ventilação natural." Master's thesis, Universidade de Aveiro, 2015. http://hdl.handle.net/10773/15822.

Full text
Abstract:
Mestrado em Sistemas Energéticos Sustentáveis
A qualidade do ar interior (QAI) em edifícios é uma preocupação que acompanha o Homem desde há séculos. A qualidade do ar interior nas escolas, em particular, tem vindo a provocar um crescente interesse, dado que o grupo populacional pertence a um grupo etário mais suscetível de ser afetado. A utilização de ferramentas numéricas de modelação na avaliação da QAI é uma mais valia, pois permite estimar as concentrações dos poluentes no interior dos edifícios. O principal objetivo deste estudo consiste na avaliação da qualidade do ar interior através da aplicação de uma ferramenta a um caso de estudo. Neste caso de estudo estimou-se a concentração de material particulado (PM10) numa sala de aula da Escola Básica nº 1 da Glória, em Aveiro. Neste âmbito, foi aplicado o modelo INDEX, Indoor Exposure model, que possibilita o cálculo de concentrações interiores de poluentes atmosféricos. Os resultados da aplicação indicam que as concentrações do ar interior são influenciadas pelas concentrações exteriores e pela velocidade do vento. Note-se, contudo, que os valores simulados cumprem os valores legislados na Portaria nº 353-A/2013, de 4 de Dezembro. Embora os resultados simulados não revelem uma má qualidade do ar interior na sala de aula da Escola Básica nº 1 da Glória, a avaliação de outros poluentes seria um ponto de extrema importância, de forma a verificar se os requisitos da qualidade do ar interior estarão a ser garantidos.
The indoor air quality (IAQ) in buildings is a concern accompanying mankind for centuries. Particularly in schools, the indoor air quality has been causing growing interest because this population’s age group is more susceptible to be affected. The use of numerical modeling tools to evaluate the IAQ is an asset because it permits estimating the concentrations of the pollutants inside buildings. The aim of this study is to evaluate indoor air quality by applying a tool to a case study. In this case study, estimated the concentration of particulate matter (PM10) in Escola Básica nº 1 da Glória in Aveiro was estimated. In this context, the model INDEX, Indoor Exposure model, which enables the calculation of indoor concentrations of air pollutants was applied. Results obtained indicate that indoor air levels are influenced by external concentrations, and wind speed. Note, however, that the simulated values are within the legislated values in Portaria nº 353-A/2013 of 4th December. Although the simulated results do not show poor indoor air quality in the classroom of the Escola Básica nº1 da Glória, the evaluation of other pollutants would be a point of extreme importance in order to verify that the indoor air quality requirements are to be guaranteed.
APA, Harvard, Vancouver, ISO, and other styles
9

Sousa, Catarina de Oliveira. "Relatório de estágio realizado na empresa HOTGAS, Lda: estudo técnico da importância da qualidade do ar interior." Master's thesis, Universidade de Aveiro, 2017. http://hdl.handle.net/10773/22759.

Full text
Abstract:
mestrado em Biotecnologia - Biotecnologia Industrial e Ambiental
Este trabalho é um relatório de estágio na empresa Hotgas, fundada a 14 de setembro de 1999. A Hotgas é uma pequena média empresa localizada em Valongo, distrito do Porto. Durante este documento vai ser exposta a temática da análise da qualidade do ar e os serviços existentes na Hotgas relacionados com essa temática e a potencialidade de crescimento da diversidade de serviços nesta mesma temática.
This work is an internship report at the company Hotgas, founded on September 14, 1999. Hotgas is a company located in Valongo, Porto district. During this document will be exposed the thematic of the air quality analysis and the existing services in Hotgas related to this theme and the potentiality of growth of the diversity of services in this same theme.
APA, Harvard, Vancouver, ISO, and other styles
10

Carvalho, Ricardo Luís Teles de. "Eficiência de fogões a biomassa e impactos na qualidade do ar interior." Master's thesis, Universidade de Aveiro, 2010. http://hdl.handle.net/10773/1821.

Full text
Abstract:
Mestrado em Sistemas Energéticos Sustentáveis
A combustão residencial de biomassa é uma forma de produção de energia térmica considerada neutra do ponto de vista de CO2 de origem fóssil, mas que pode ter impactos na qualidade do ar. O presente trabalho teve como objectivo analisar o desempenho energético e ambiental de diferentes fogões a biomassa utilizados em habitações unifamiliares. Como resultado da aplicação de um modelo numérico de simulação dinâmica – BSIM Building Simulation – e das experiências realizadas em 6 habitações unifamiliares na Dinamarca verificou-se que os fogões a biomassa emitem energia térmica de forma intermitente, sendo que, a utilização dos fogões certificados conduziu a um sobreaquecimento das habitações com elevada eficiência energética. Nas experiências realizadas em habitações unifamiliares na Dinamarca verificaram-se consumos anuais de energia final para aquecimento de espaços a variar entre os 9,0 e os 31,6 MWh, taxas de renovação de ar novo entre os 0,34 e os 1,02 h-1, tendo-se determinado concentrações de partículas PM10 e PM1 acima dos 150 μg m-3, aquando da combustão de biomassa nos fogões a em edifícios residenciais construídos no ano de 2009. Verificou-se também que, a concentração de partículas ultra-finas variou consideravelmente após a ignição da combustão de biomassa para todos os fogões analisados, independentemente do ano de construção dos edifícios onde se realizaram as medições. Os caudais de emissão (valores máximos) de partículas ultra-finas, dos fogões a biomassa para o interior das habitações em estudo, variaram entre 9,19 x 107 e 1,96 x 1015 partículas ultra-finas h-1, tendo-se observado as concentrações mais elevadas para este tipo de partículas, nos ambientes interiores em estudo, no momento em que se verificaram os caudais de emissão de partículas mais elevados. Em geral, para os restantes parâmetros de caracterização da qualidade do ar não se verificaram impactos da combustão doméstica de biomassa na QAI. Da análise energética ao recuperador de calor típico Português estimou-se uma eficiência térmica a variar entre os 50% e os 77%, dependendo da fase do ciclo de combustão de biomassa, sendo que a temperatura na câmara de combustão nestes sistemas varia entre os 100 e os 600 oC. Da análise do cálculo da eficiência para diferentes intervalos de tempo, podemos verificar que, durante a combustão de Freixo, a transferência de calor do fogão a biomassa para o interior do edifício é máxima para temperaturas na câmara de combustão superiores a 400 C e caudais de ar de combustão de 30 Nm3 h-1. O fluxo de calor total do equipamento para o interior do edifício foi de 6,25 kW, para um intervalo durante o ciclo de combustão, aquando a operação do sistema segundo as condições típicas de operação. ABSTRACT: The residential combustion of biomass is a form of production of thermal energy, considered neutral in terms of CO2 produced from fossil fuels, but that may have impacts on air quality. This study aimed to analyze the energy and environmental performance of different biomass stoves used in private homes. As a result of applying a numerical model for dynamic simulation - BSIM Building Simulation - and the experiences carried out in 6 detached houses located in Denmark, it was found out that, the wood burning stoves emit thermal energy intermittently, and the use of certified appliances led to overheating of dwellings with high energy efficiency. In experiments conducted in single family houses in Denmark, final energy consumption for residential heating varied between 9,0 and 36,6 MWh and air exchange rate varied between 0.34 and 1.02 h-1. Concentrations of PM10 and PM1 were found to be above 150 μg m-3, when wood burning stoves were used for space heating in residential buildings constructed in the year of 2009. It was also found that, the concentration of ultra-fine particles varied considerably after ignition of biomass combustion for all stoves tested, independently of the year when the dwellings, where measurements were carried out, were constructed. The rates of emission (maximum values) of ultra-fine particles, from biomass stoves to the interior of the houses analysed in the developed case study, ranged between 9.19 x 107 and 1.96 x 1015 ultra-fine particles h-1 and it was observed that, the highest indoor concentrations for this type of particles, occurred when the ultra-fine particles emission rate was the highest. In general, for the other parameters that characterize the indoor air quality (IAQ), there were no impacts of the combustion of biomass in the IAQ. The energy analysis of the typical Portuguese wood burning stove handed in a thermal efficiency in the range from 50% to 77%, depending on the phase of the combustion cycle considered in this study. The temperature in the combustion chamber in these systems varied in between 100 and 600 oC. From the previous energy analysis, regarding the wood burning efficiency calculation for different time intervals, we can conclude that, during the wood combustion process, the heat transfer from the wood burning stove to the indoor space happens when the temperature in the combustion chamber is above 400 C and combustion air flow rate is equal to 30 Nm3h-1. The total heat flow of the tested equipment into the building was 6,25 kW for an interval during the combustion cycle operated under the typical conditions of utilization.
APA, Harvard, Vancouver, ISO, and other styles
More sources

Books on the topic "Qualidade do ar interior"

1

Machado, Paulo Affonso Leme. Direito à informação ambiental e qualidade do ar. São Paulo: Instituto de Energia e Meio Ambiente, 2009.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
2

Santana, Eduardo Rodrigo Ramos de. Padrões de qualidade do ar: Experiência comparada Brasil, EUA e União Européia. São Paulo: Instituto de Energia e Meio Ambiente, 2012.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
3

Swartz, Merlin. A medieval critique of anthropomorphism: Ibn al-Jawzi's Kitab Akhbar as-sifat : a critical edition of the Arabic text with translation, introduction and notes. Leiden: Brill, 2001.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
4

Leite, Zurita Manuel Luiz, Tolfo Alessandra Moschem, and Porto Alegre (Brazil). Secretaria Municipal do Meio Ambiente., eds. A qualidade do ar em Porto Alegre. Porto Alegre: Prefeitura Municipal de Porto Alegre, Secretaria Municipal do Meio Ambiente, 2000.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
5

Diretrizes globais de qualidade do ar da OMS: partículas inaláveis (MP2,5 e MP10), ozônio, dióxido de nitrogênio, dióxido de enxofre e monóxido de carbono. Resumo executivo. Pan American Health Organization, 2021. http://dx.doi.org/10.37774/9789275724613.

Full text
Abstract:
A carga global de doenças associadas à exposição à poluição do ar tem um impacto enorme na saúde humana em todo o mundo: estima-se que a exposição à poluição do ar cause milhões de mortes e anos perdidos de vida saudável anualmente. Estima-se que a carga de doenças atribuíveis à poluição do ar já seja comparável a de outros importantes riscos globais à saúde, como alimentação não saudável e tabagismo, e reconhece-se que a poluição do ar é agora a maior ameaça ambiental à saúde humana. O principal objetivo dessas diretrizes globais atualizadas é oferecer padrões de qualidade do ar pensados para a saúde, expressos como concentrações a longo ou curto prazo, para seis importantes poluentes atmosféricos: MP2,5, MP10, ozônio, dióxido de nitrogênio, dióxido de enxofre e monóxido de carbono. Além disso, as diretrizes fornecem metas intermediárias para orientar os esforços de redução desses poluentes, bem como declarações de boas práticas para o gerenciamento de certos tipos de MP (carbono negro/carbono elementar, partículas ultrafinas e partículas originadas de tempestades de areia e poeira) . Essas diretrizes não são uma norma juridicamente vinculativa; no entanto, fornecem aos Estados Membros da OMS uma ferramenta baseada em evidências que podem usar para subsidiar legislação e políticas. Em última análise, o objetivo dessas diretrizes é ajudar a reduzir os níveis de poluentes atmosféricos a fim de diminuir a enorme carga de morbidade resultante da exposição à poluição atmosférica em todo o mundo.
APA, Harvard, Vancouver, ISO, and other styles
6

VANESSA ANDRIANI, MARIA. Secagem e armazenamento de grãos de trigo e sua influência nas análises físico-químicas e tecnológicas. Taurite, 2020. http://dx.doi.org/10.35417/978-65-89029-02-1.

Full text
Abstract:
É importante que o trigo passe por um processo de secagem adequado para manter a qualidade dos grãos, mantendo a qualidade e minimizando as perdas decorrentes da colheita. Geralmente, os grãos precisam passar por um adequado processo de secagem após sua colheita antes de serem submetidos à armazenagem. Frente à demanda por informações consistentes e aprofundadas que caracterizem o impacto da temperatura no processo de secagem do trigo, objetivou-se com o presente trabalho avaliar o impacto de diferentes temperaturas do ar de secagem na composição química, física e tecnológica de grãos de trigo.
APA, Harvard, Vancouver, ISO, and other styles
7

Roteiro para melhorar e garantir a boa ventilação de ambientes fechados no contexto da doença causada pelo novo coronavírus,COVID-19. Pan American Health Organization, 2021. http://dx.doi.org/10.37774/9789275723807.

Full text
Abstract:
O risco de contrair COVID-19 é maior em ambientes com aglomerações e com ventilação inadequada, onde pessoas infectadas passam longos períodos juntas e muito próximas. Estes são os ambientes onde o vírus parece se disseminar com maior eficiência, por gotículas respiratórias ou aerossóis, tornando as precauções, portanto, ainda mais importantes. A compreensão e controle da ventilação das edificações pode melhorar a qualidade do ar que respiramos e reduzir o risco de problemas de saúde em ambientes fechados, inclusive melhorando a prevenção contra o vírus que causa a propagação da COVID-19 nesses ambientes. Este roteiro foi desenvolvido após uma revisão abrangente da literatura disponível e de uma avaliação dos documentos de orientação disponíveis das principais e mais renomadas autoridades internacionais em ventilação de edificações. As evidências e orientações disponíveis foram consultadas, reunidas e avaliadas quanto a quaisquer discrepâncias por especialistas internacionais membros do Painel Consultivo de Especialistas no Controle de Engenharia e Meio Ambiente (ECAP) da Organização Mundial da Saúde (OMS) para a COVID-19. O processo de desenvolvimento do roteiro incluiu duas sessões de consulta a especialistas por meio de reuniões virtuais e duas rodadas de apresentações por escrito, visando reunir contribuições técnicas e assegurar a construção de um consenso para a adaptação das recomendações. Esse processo considerou as metas de prevenção e controle de infecções (PCI), as implicações de recursos, valores e preferências, a ética e as lacunas de pesquisa no escopo do desenvolvimento do roteiro.
APA, Harvard, Vancouver, ISO, and other styles
8

Pereira, Álex Sousa, Fábio Pinto Gonçalves dos Reis, Kleber Tüxen Carneiro, and Alcides José Scaglia. Pedagogia das lutas/artes marciais: Do ambiente de jogo à sistematização do ensino. Brazil Publishing, 2021. http://dx.doi.org/10.31012/978-65-87836-42-3.

Full text
Abstract:
Trata-se de uma obra com arrojado grau de originalidade e uma eloquente preocupação com aqueles que se dedicam ao exercício do ensino, notadamente no que se refere às Lutas/Artes Marciais. Sob a acepção de um livro-experiência, sua trama procura situar epistemologicamente a Educação Física enquanto componente curricular, por efeito os saberes corporais relativos às Lutas/Artes Marciais em seu interior. Na qualidade de uma literatura didático-científica, expõe conceitos sem, porém, concebê-los linearmente, já que se assentada em uma perspectiva rizomática. Adjudica ao jogo (de oposição) uma condição sine qua non para se pensar o ensino das Lutas/Artes Marciais. Com efeito, apresenta uma proposta de organização de seus saberes, a qual desestabiliza os interditos que comumente impedem sua presença no ambiente escolar. Por certo se trata de uma contribuição que fornece subsídios para se pensar e debater o mote, porquanto, quando ensinado, tem superestimado os processos formativos mecânicos e descontextualizados, em detrimento de um ensino diversificado e que produza sentido/significado ao aprendiz. Configura-se, portanto, em uma leitura aprazível e indispensável para expansão das margens formativas.
APA, Harvard, Vancouver, ISO, and other styles
9

Shinohara, Neide Kazue Sakugawa, Fábio Henrique P. C. de Oliveira, Isabel Lausanne Fontgalland, and Higor Costa de Brito. Meio ambiente e sociedade: análises, diálogos e conflitos ambientais. 3rd ed. Editora Amplla, 2022. http://dx.doi.org/10.51859/amplla.mas1051-0.

Full text
Abstract:
A preocupação com o meio ambiente tem-se tornado meta para a economia global, porque envolve desafios de responsabilidade social alinhados com o desenvolvimento econômico sustentável. Segundo o Programa das Nações Unidas para o Meio Ambiente (Pnuma) o mundo vive três crises ambientais simultâneas: as mudanças do clima, a vulnerabilidade da biodiversidade e a eutrofização em vários ecossistemas. O reconhecimento de que a natureza possui recursos naturais finitos tem motivado várias ações conjuntas, afim de proteger o ar, o ambiente aquático, o solo e suas biotas, permitindo o bom funcionamento dos diferentes ecossistemas, visto que os elementos ecossistêmicos estão intimamente interconectados em uma rede de influência mútua, trocando energia e matéria-prima. Com o intuito de preservar o meio ambiente no planeta, os 193 países membros da Organização das Nações Unidas (ONU) adotaram uma nova política global em 2015, a Agenda 2030, cuja proposta sintetiza as aspirações e integra as dimensões econômica, social e ambiental, baseado em cinco princípios orientadores (5P): Pessoas, Planeta, Prosperidade, Paz e Parcerias. Representam pactos universais que visam promover prosperidade econômica e justiça social, estimulando a economia verde e solidária, independentemente da localização geográfica e construção histórica das populações do planeta. É preocupante que os ecossistemas têm sido cada vez mais afetados pela falta de conscientização de uma parcela da população que produz excedente de lixo doméstico, bem como as indústrias de transformação que podem lançar rejeitos e produtos químicos tóxicos em rios, barragens e oceanos. São essas ações humanas que comprometem a qualidade da água e do solo saudável para cultivo de alimentos, demandando o aumento de investimentos público e privado, uso de tecnologias mitigatórias dispendiosas para tratamento e reversão de poluentes ambientais. Ainda, os órgãos fiscalizadores devem monitorar que produtos oriundos dessa transformação atendam resoluções e legislações vigentes, garantindo que esse retorno à cadeia produtiva e de consumo, seja comprovadamente seguro para uso dos seres humanos e animais. A queima de combustíveis fósseis e a emissão de poluentes tóxicos influencia a qualidade do ar e dos recursos hídricos, podendo comprometer a saúde pública, restringir a mobilidade das pessoas e potencializar impactos ambientais danosos, a exemplo da chuva ácida, intensificação do efeito estufa e florações de algas nos corpos d’água. Esses eventos, associados ao aquecimento global e outros desequilíbrios climáticos, tem feito o mundo assistir a episódios de secas ou enchentes em períodos não previstos, com impactos negativos na produção de alimentos, provocando desastres naturais e desigualdades sociais significativos. As políticas de Estado devem contar com planejamento estratégico ambiental, incentivando a criação, manutenção e proteção de áreas de preservação e reserva legal, definidos como espaços delimitados com características naturais relevantes e considerados essenciais do ponto de vista econômico e de sustentabilidade, por protegerem os recursos hídricos, a biodiversidade natural e da compensação de perdas causadas pelas ações humanas. Essas áreas também tem como objetivo oportunizar interesses na economia verde, como ponto de partida para financiamento de projetos sustentáveis para o bem estar das populações, com redução dos impactos ambientais negativos e oportunidade de geração de emprego e renda, a exemplo de projetos de reciclagem que transformam a coleta de produtos inservíveis em produto rentável. Espera-se que grandes desafios ambientais possam conscientizar e mobilizar governos de diferentes etnias, a sociedade humana, agências reguladoras e organizações intergovernamentais de cooperação internacional, para frear ações que possam comprometer o meio ambiente e a sobrevivência das gerações futuras. Nesta perspectiva, os trabalhos presentes nessas obras são contribuições científicas atualizadas abordando esta temática, a fim de que possamos, a partir dos diferentes ramos das ciências, compartilhar o conhecimento, fatos e ações que visam à promoção de estratégias viáveis para lidar com os desafios no meio ambiente no Brasil e no Mundo.
APA, Harvard, Vancouver, ISO, and other styles
10

Shinohara, Neide Kazue Sakugawa, Fábio Henrique P. C. de Oliveira, Isabel Lausanne Fontgalland, and Higor Costa de Brito. Meio ambiente e sociedade: análises, diálogos e conflitos ambientais. 2nd ed. Editora Amplla, 2022. http://dx.doi.org/10.51859/amplla.mas1044-0.

Full text
Abstract:
A preocupação com o meio ambiente tem-se tornado meta para a economia global, porque envolve desafios de responsabilidade social alinhados com o desenvolvimento econômico sustentável. Segundo o Programa das Nações Unidas para o Meio Ambiente (Pnuma) o mundo vive três crises ambientais simultâneas: as mudanças do clima, a vulnerabilidade da biodiversidade e a eutrofização em vários ecossistemas. O reconhecimento de que a natureza possui recursos naturais finitos tem motivado várias ações conjuntas, afim de proteger o ar, o ambiente aquático, o solo e suas biotas, permitindo o bom funcionamento dos diferentes ecossistemas, visto que os elementos ecossistêmicos estão intimamente interconectados em uma rede de influência mútua, trocando energia e matéria-prima. Com o intuito de preservar o meio ambiente no planeta, os 193 países membros da Organização das Nações Unidas (ONU) adotaram uma nova política global em 2015, a Agenda 2030, cuja proposta sintetiza as aspirações e integra as dimensões econômica, social e ambiental, baseado em cinco princípios orientadores (5P): Pessoas, Planeta, Prosperidade, Paz e Parcerias. Representam pactos universais que visam promover prosperidade econômica e justiça social, estimulando a economia verde e solidária, independentemente da localização geográfica e construção histórica das populações do planeta. É preocupante que os ecossistemas têm sido cada vez mais afetados pela falta de conscientização de uma parcela da população que produz excedente de lixo doméstico, bem como as indústrias de transformação que podem lançar rejeitos e produtos químicos tóxicos em rios, barragens e oceanos. São essas ações humanas que comprometem a qualidade da água e do solo saudável para cultivo de alimentos, demandando o aumento de investimentos público e privado, uso de tecnologias mitigatórias dispendiosas para tratamento e reversão de poluentes ambientais. Ainda, os órgãos fiscalizadores devem monitorar que produtos oriundos dessa transformação atendam resoluções e legislações vigentes, garantindo que esse retorno à cadeia produtiva e de consumo, seja comprovadamente seguro para uso dos seres humanos e animais. A queima de combustíveis fósseis e a emissão de poluentes tóxicos influencia a qualidade do ar e dos recursos hídricos, podendo comprometer a saúde pública, restringir a mobilidade das pessoas e potencializar impactos ambientais danosos, a exemplo da chuva ácida, intensificação do efeito estufa e florações de algas nos corpos d’água. Esses eventos, associados ao aquecimento global e outros desequilíbrios climáticos, tem feito o mundo assistir a episódios de secas ou enchentes em períodos não previstos, com impactos negativos na produção de alimentos, provocando desastres naturais e desigualdades sociais significativos. As políticas de Estado devem contar com planejamento estratégico ambiental, incentivando a criação, manutenção e proteção de áreas de preservação e reserva legal, definidos como espaços delimitados com características naturais relevantes e considerados essenciais do ponto de vista econômico e de sustentabilidade, por protegerem os recursos hídricos, a biodiversidade natural e da compensação de perdas causadas pelas ações humanas. Essas áreas também tem como objetivo oportunizar interesses na economia verde, como ponto de partida para financiamento de projetos sustentáveis para o bem estar das populações, com redução dos impactos ambientais negativos e oportunidade de geração de emprego e renda, a exemplo de projetos de reciclagem que transformam a coleta de produtos inservíveis em produto rentável. Espera-se que grandes desafios ambientais possam conscientizar e mobilizar governos de diferentes etnias, a sociedade humana, agências reguladoras e organizações intergovernamentais de cooperação internacional, para frear ações que possam comprometer o meio ambiente e a sobrevivência das gerações futuras. Nesta perspectiva, os trabalhos presentes nessas obras são contribuições científicas atualizadas abordando esta temática, a fim de que possamos, a partir dos diferentes ramos das ciências, compartilhar o conhecimento, fatos e ações que visam à promoção de estratégias viáveis para lidar com os desafios no meio ambiente no Brasil e no Mundo.
APA, Harvard, Vancouver, ISO, and other styles

Book chapters on the topic "Qualidade do ar interior"

1

Sultana, Maryam, In Su Kim, and Soon Ki Jung. "Deep Matting for AR Based Interior Design." In Communications in Computer and Information Science, 31–42. Singapore: Springer Singapore, 2020. http://dx.doi.org/10.1007/978-981-15-4818-5_3.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Junior, Divino Vital da Silva, Eliandro Barbosa de Aguiar, and Alexandre Fernandes Santos. "IMPACTOS DA QUALIDADE DO AR INTERIOR." In Ciências da saúde: Pluralidade dos aspectos que interferem na saúde humana 6, 152–69. Atena Editora, 2021. http://dx.doi.org/10.22533/at.ed.77221091115.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Gomes, Maria Idália, Paulina Faria, and João Gomes. "MELHORIA DA QUALIDADE DO AR INTERIOR ATRAVÉS DA UTILIZAÇÃO DE ARGAMASSAS ECOEFICIENTES." In Discussões Efetivas sobre a Sustentabilidade, 50–65. Atena Editora, 2021. http://dx.doi.org/10.22533/at.ed.2192103314.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Ferreira, Ana Paula, Brennda Ribeiro Paupitz, Débora Elisa Antunes de Mendonça, Emmanuel Predestin, Fernanda Amaral Della Rosa, Gustavo Fernando da Silva, Joice Lazarin Romão, Keila Mileski Pontes, Marcelo Teixeira Silva, and Helio Conte. "MELHORIA NA QUALIDADE DE VIDA EM AMBIENTES INTERNOS COM PLANTAS REMOVEDORAS DE FORMALDEÍDO DO AR." In Meio Ambiente: Inovação com Sustentabilidade, 212–22. Atena Editora, 2019. http://dx.doi.org/10.22533/at.ed.45419011024.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Teixeira, Danielle Cardozo Frasca, Gislene Figueiredo Ortiz Porangaba, and Margarete Cristiane de Costa Trindade Amorim. "O CLIMA URBANO COMO ATRIBUTO DE QUALIDADE AMBIENTAL ANÁLISE SOBRE A RENDA E A TEMPERATURA DO AR EM CIDADES DE PEQUENO PORTE DO INTERIOR PAULISTA, BRASIL." In Dinâmicas Naturais e Humanas nos Ambientes Urbanos, 85–96. Compasso Lugar-Cultura, 2022. http://dx.doi.org/10.29327/554448.1-4.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Sousa, Valdineide Reis de, Marcos Victor do Carmo Loiola, and Jairton Fraga Araújo. "CULTURA DO MELÃO." In Manual técnico sobre mercados e canais de comercialização de culturas agrícolas no submédio São Francisco, 122–41. Bookerfield Editora, 2022. http://dx.doi.org/10.53268/bkf22010206.

Full text
Abstract:
A cultura do melão (Cucumis melo L., Cucurbitaceae) representa um importante segmento para a fruticultura irrigada no Nordeste do Brasil. A região é considerada como o principal produtor de melão do país contribuindo com mais de 90% da produção nacional. A região do Vale do São Francisco se destaca como um polos principais do cultivo do meloeiro. A disponibilidade de áreas irrigadas pelas águas do Rio São Francisco associadas às condições climáticas favorece a produção do melão na região ofertando possibilidade de plantio e colheita durante o ano inteiro, no entanto, seu cultivo pode ocorrer em qualquer parte do território brasileiro, não tolerando apenas áreas de ventos frios e geadas. A temperatura é o principal fator que afeta diretamente a cultura e produtividade dos frutos, uma vez que ela influencia no teor, sabor, aroma e consistência dos frutos. O Vale do São Francisco é caracterizado por temperaturas entre 25º e 32ºC, baixa umidade do ar e poucas chuvas, condicionando a região assim para o cultivo ideal do meloeiro que por sinal se produzem frutos mais doces, com maiores concentrações de teor de açúcar, sendo este um fator positivo principalmente para aos processos de exportação. É importante compreender que o modo de conduzir a produção do melão tem enorme influência na qualidade do produto final, alguns fatores como o adequado transporte dos frutos, uso das câmaras de frios, embalagem e conservação pós-colheita estão intimamente associados ao padrão de qualidade final do produto principalmente para atender aos consumidores mais exigentes. Em virtude dos benefícios nutricionais do melão o fruto é bastante consumido no mercado interno e externo. Possui vitaminas A, B, B2, B5, potássio, sódio e fósforo, sendo o consumo in natura ou na forma de sucos, sorvetes e pudins e suas sementes podem ser consumidas torradas. O fruto possui propriedades medicinais, calmante, diurética e de laxante. A disseminação desses benefícios, contribui para ampliação das demandas de consumo do fruto favorecendo a viabilidade econômica da cultura.
APA, Harvard, Vancouver, ISO, and other styles
7

Pellanda, Andressa. "ODS 4 - Educação de qualidade." In Leituras dos ODS para um Brasil Sustentável, 59–69. V&V Editora, 2021. http://dx.doi.org/10.47247/vv/ar/88471.17.3.4.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Santos, Thairine Lima dos, and Celeste Yara dos Santos Siqueira. "QUALIDADE DO AR: MARCADORES DE PAPEL DE BIBLIOTECA." In Química: Debate entre a Vida Moderna e o Meio Ambiente, 49–58. Atena Editora, 2021. http://dx.doi.org/10.22533/at.ed.7832112046.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Rocha, Elenilton Santos, and Manoel Camilo Moleiro Cabrera. "ELIMINADORES E BLOQUEADORES DE AR NAS INSTALAÇÕES PREDIAIS." In Força, Crescimento e Qualidade da Engenharia Civil no Brasil 2, 173–81. Atena Editora, 2021. http://dx.doi.org/10.22533/at.ed.89521080213.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Moura, Sylvia Katherine de Medeiros, Antonio Calmon de Araújo Marinho, Wagner Amadeus Galvão de Souza, and Angelo Roncalli Oliveira Guerra. "ANÁLISE DA QUALIDADE DO AR INTERNO DE UMA TERAPIA INTESIVA." In As Engenharias frente a Sociedade, a Economia e o Meio Ambiente 2, 348–56. Atena Editora, 2019. http://dx.doi.org/10.22533/at.ed.30619250629.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Conference papers on the topic "Qualidade do ar interior"

1

das Chagas Silva, Joiciney, Antonia Debora Sales, Carlos Alberto de Castro Oliveira Júnior, Luciando Cabral Moreira, and Tiago Morais da Costa. "A QUALIDADE DO AR INTERIOR EM AMBIENTES DE HOSPITAL." In 20XX CONEMI. ,: Even3, 2021. http://dx.doi.org/10.29327/conemi.302817.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Silva, Laurie Mélany Marques da, and Maryana Antônia Braga Batalha Souza. "AVALIAÇÃO DA QUALIDADE DO AR INTERIOR DE DOIS SHOPPING CENTERS DA CIDADE DE MANAUS/AM E SUA RELAÇÃO COM A SAÚDE PÚBLICA." In II Congresso On-line Internacional de Sustentabilidade. Revista Multidisciplinar de Educação e Meio Ambiente, 2021. http://dx.doi.org/10.51189/rema/2047.

Full text
Abstract:
Introdução: Quando se trata de ambientes internos, a climatização do ar torna os ambientes agradáveis, mas pode provocar concentração de poluentes – gás carbônico, microrganismos e poeira em suspensão, entre outros. Alguns estudos comprovam que o desequilíbrio na qualidade do ar interior causa agravos à saúde dos ocupantes e visitantes. Desta forma, a Organização Mundial da Saúde (OMS) recomenda, e muitos países mantêm e seguem, padrões e critérios para a qualidade do ar no interior dos ambientes climatizados por ar condicionado, onde locais ocupados ou frequentados por muitas pessoas, esse cuidado é especialmente importante. Objetivos: Analisar, por meio de um levantamento bibliográfico de cunho qualitativo exploratório, como a qualidade do ar interior pode causar danos à saúde, somado a uma avaliação de dois ambientes localizados na cidade de Manaus/AM. Material e Métodos: Consistiu no levantamento bibliográfico acerca do tema escolhido, assim também, como a realização da análise da qualidade do ar interior de dois shopping centers da cidade de Manaus/AM realizada no mês de fevereiro de 2021, afim de verificar a sua relação com a saúde pública. Para isso, foram utilizados materiais de uso permanente, consumo e serviços na realização da coleta dos parâmetros de concentração de CO2, temperatura, umidade relativa, velocidade do ar, concentração de material particulado, concentração de fungos, bolores e bactérias para posterior comparação com os parâmetros aceitos pela Agência Nacional de Vigilância Sanitária (ANVISA). Resultados: Através da comparação dos parâmetros físico-químicos e biológicos da qualidade do ar interior dos shoppings com os parâmetros aceitos pela ANVISA, foi possível observar que os dois ambientes monitorados apresentaram conformidade para todos os parâmetros analisados, atendendo os limites estabelecidos pela legislação. Conclusão: Essa pesquisa tem como contribuição social integrar a literatura existente sobre avaliação da qualidade do ar interior, pois os ambientes analisados são shoppings com elevada popularidade na cidade de Manaus/AM, além de contribuir com pesquisas futuras. Portanto, a importância deste trabalho está ligada não somente a verificação do cumprimento da legislação, mas principalmente apresentar os possíveis danos que um ambiente com má qualidade do ar interior pode causar a saúde humana.
APA, Harvard, Vancouver, ISO, and other styles
3

Silva, Melyssa M. G., Antônio E. Pereira, Isabela F. França, Bruna M. O. S. Cordeiro, Iwens G. Sene Junior, and Renato F. Bulcão-Neto. "Compatibilidade entre a Qualidade do Ar Interno e a Percepção do Usuário." In Escola Regional de Computação Aplicada à Saúde. Sociedade Brasileira de Computação - SBC, 2021. http://dx.doi.org/10.5753/ercas.2021.17444.

Full text
Abstract:
A poluição do ar tem aumentado progressivamente nosúltimos anos, tornando-se o risco ambiental mais significativo para a saúde humana. Por isso, deve haver uma avaliação da qualidade do ar interno (QAI) por meio de dados obtidos por sensores e da percepção dos frequentadores do ambiente monitorado. Este artigo descreve uma solução baseada em IoT para monitoramento de QAI e mostra como calculamos a compatibilidade entre a qualidade do ar detectada e percebida.
APA, Harvard, Vancouver, ISO, and other styles
4

França, Isabela F., Antônio E. Pereira, Melyssa M. G. Silva, Bruna M. O. S. Cordeiro, Iwens G. Sene Junior, and Renato F. Bulcão-Neto. "SASO: Sistema de Apoio à Saúde Ocupacional." In Escola Regional de Computação Aplicada à Saúde. Sociedade Brasileira de Computação - SBC, 2021. http://dx.doi.org/10.5753/ercas.2021.17445.

Full text
Abstract:
A população economicamente ativa passa, em média, cerca de um terço de seu tempo no local de trabalho e os problemas de saúde aí causados resultam em perdas econômicas para a maioria dos países. Considerando que a qualidade do ar é um dos principais problemas de saúde pública, é fundamental que haja um monitoramento constante nos locais de trabalho. Assim, este artigo tem como objetivo apresentar o Sistema de Apoio à Saúde Ocupacional (SASO) que consiste em uma solução IoT que monitora, em tempo real, a qualidade do ar em ambientes internos e climatizados, disponibilizando as informações coletadas em um painel para o usuário final .
APA, Harvard, Vancouver, ISO, and other styles
5

Santos, Deyse Melo, and Jose Jailton Marques. "CONSTRUÇÃO DE UM SISTEMA PARA MEDIDA DA CONCENTRAÇÃO DE COVS NA PLATAFORMA ARDUINO." In II Congresso On-line Internacional de Sustentabilidade. Revista Multidisciplinar de Educação e Meio Ambiente, 2021. http://dx.doi.org/10.51189/rema/2026.

Full text
Abstract:
Introdução: Nas sociedades contemporâneas, a maior parte das pessoas passa cerca de 90% do tempo em espaços fechados. Com isso, a qualidade do ar interior (QAI) dos edifícios assume uma importância, devido à presença de poluentes nesses ambientes, em decorrência do uso dos materiais de construção e decoração sintéticos e das atividades humanas. Tendo em vista que a respiração de um ar poluído provoca efeitos negativos para a saúde e a produtividade, afetando o bem-estar dos seus ocupantes, torna-se imprescindível a aplicação de técnicas e procedimentos para diminuir a concentração de poluentes em ambientes confinados. Objetivos: O objetivo do projeto foi desenvolver um sistema de baixo custo para medição/monitoramento da concentração de compostos orgânicos voláteis (COVs) em ambientes confinados, utilizando a tecnologia Arduino e a avaliar a aplicabilidade do processo de adsorção para o abatimento de compostos orgânicos voláteis (COVs) em ambientes confinados. Materiais e Métodos: utilizando como adsorventes, cabelo humano in natura e biochar sintetizado a partir da casca de coco verde. Para tanto, construiu-se um aparato experimental para a realização dos testes de adsorção em leito fixo e fluxo contínuo, utilizado para o levantamento de dados por meio de ensaios de adsorção dinâmicos e construção das respectivas curvas de breakthrough e consequente levantamento de parâmetros para o projeto de equipamentos. Resultados: Os resultados mostraram eficiências de adsorção do formaldeído pelo biochar de aproximadamente 100%, para uma altura do leito de adsorção de 13 cm. Já o cabelo humano apresentou eficiências de adsorção entre 30 e 40%, exigindo tempo de contato maior entre o poluente e o adsorvente, para a obtenção de melhores resultados. Conclusão: Os dois materiais analisados podem ser empregados para o abatimento de formaldeído em ambientes confinados.
APA, Harvard, Vancouver, ISO, and other styles
6

Siqueira, Ingrid de Souza, Anália Arêdes, Bruno Dos Santos Esteves, and Aline Chaves Intorne. "CIÊNCIA E SOCIEDADE NA RÁDIO." In II Congresso On-line Internacional de Sustentabilidade. Revista Multidisciplinar de Educação e Meio Ambiente, 2021. http://dx.doi.org/10.51189/rema/2098.

Full text
Abstract:
Introdução: A rádio é um importante meio de comunicação capaz de atingir um grande número pessoas, de diferentes classes sociais, faixas etárias e níveis de escolaridade, enquanto executam tarefas do cotidiano. A divulgação científica por meio da rádio, principalmente durante a pandemia da Covid-19, leva aos ouvintes informações de qualidade necessárias sobre diversos aspectos da ciência e da sociedade, tais como saúde pública e sustentabilidade. Objetivo: Utilizar a rádio para comunicar ciência com a sociedade. Material e Métodos: Desde junho de 2020, semanalmente foram criadas pautas baseadas em pesquisas sobre temas de relevância para a sociedade, que foram transmitidos no quadro “Ciência pra Gente”. Com duração média de 20 minutos, o quadro foi transmitido “ao vivo” nas terças-feiras às 10 horas na “Rádio Via 5”, uma rádio on-line com sede no município de São Fidélis/RJ, localizado na região Norte Fluminense. A gravação foi divulgada pelo Facebook® da rádio e pelas mídias sociais do projeto “Ciência pra Gente”, sendo analisadas as métricas através do “Instagram Analytics” e o “YouTube Studio”. Resultados: Foram ao ar 55 quadros do “Ciência pra Gente” na “Rádio Via5”, destaca-se: “Riscos e impactos do clima”, “As caras do Pantanal”, “O avanço da Covid no interior e na periferia” e “Falta de energia. Como Resolver?”, atingindo uma média de 3 mil ouvintes por programa. Através do Facebook® da rádio foi possível interagir com pessoas de diversas cidades nos comentários, como por exemplo, ouvintes do município São Gonçalo, que fica a mais de 300 km de São Fidélis, e Resende, uma cidade localizada no sul do Estado do Rio de Janeiro. Isso mostra que a rádio é uma ótima ferramenta para fazer difundir a ciência. Nas mídias sociais do projeto, atingiu-se em média 240 impressões por tema do Instagram® e 98 visualizações no YouTube®. Conclusão: A quantidade significativa de ouvintes e o bom engajamento nas mídias sociais mostram como a divulgação científica por meio da rádio tem potencial para transmitir informação de qualidade à população, possibilitando inclusão social e acesso a ciência para todas as pessoas.
APA, Harvard, Vancouver, ISO, and other styles
7

Erbs, Vicente Knihs, and Wyllian Bezerra da Silva. "SISTEMA DE MAPEAMENTO DA QUALIDADE DO AR." In Congresso Brasileiro Interdisciplinar em Ciência e Tecnologia. Recife, Brasil: Even3, 2021. http://dx.doi.org/10.29327/142529.2-5.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Souza, Marina Alvarenga de, Fernanda Paula Bicalho Pio, Diego José Rodrigues Pimenta, Tarik Silveira Cordeiro, and Ana Carolina Vasques Freitas. "PORTAL DE MONITORAMENTO DA QUALIDADE DO AR – ITABIRAR." In I Congresso Nacional On-line de Conservação e Educação Ambiental. Revista Multidisciplinar de Educação e Meio Ambiente, 2021. http://dx.doi.org/10.51189/rema/2365.

Full text
Abstract:
Introdução: Os poluentes atmosféricos podem trazer prejuízos à saúde, ao meio ambiente e ao bem-estar da população. Cada localidade tem suas fontes particulares de poluição e, portanto, os poluentes a serem monitorados devem ser determinados em cada cidade, caracterizando e quantificando as contribuições dos poluentes emitidos por cada uma das fontes emissoras. A qualidade do ar pode mudar devido às condições meteorológicas, que podem promover uma maior ou menor diluição dos poluentes. O município de Itabira, localizado no Estado de Minas Gerais, possui uma Rede Automática de Monitoramento da Qualidade do Ar. Esta rede é composta de cinco estações, sendo uma meteorológica. A análise da qualidade do ar é realizada por meio do monitoramento dos seguintes parâmetros: Partículas Totais em Suspensão (PTS), Material Particulado fino (MP2,5) e grosso (MP10). A estação meteorológica fornece dados relativos à precipitação, temperatura, radiação solar, pressão atmosférica, velocidade e direção do vento e umidade relativa. Objetivos: Com o objetivo de tornar conhecido os dados de monitoramento da qualidade do ar em Itabira de forma transparente e ágil, a Secretaria Municipal de Meio Ambiente (SMMA) de Itabira inaugurou o Portal do ar, denominado ItabirAR. Materiais e métodos: O portal é fruto de um trabalho desenvolvido pelos técnicos da SMMA e Informática em parceria com a UNIFEI (Universidade Federal de Itajubá). Para que o trabalho fosse desenvolvido foi necessária utilização da linguagem de programação, realização de testes de validação, inserção de tabelas e gráficos. Resultados: O Portal ItabirAR disponibiliza o Índice de Qualidade do Ar (IQAr), as médias diárias dos poluentes monitorados, artigos científicos, materiais educativos, uma aba para denúncias e boletins interpretativos mensais. Conclusão: O ItabirAR é uma inovação para o município, pois propicia inúmeros benefícios para a comunidade, fornecendo informações em linguagem acessível acerca da qualidade do ar, propiciando uma maior conscientização ambiental. Essa ferramenta facilita o acesso a informações importantes, servindo para acelerar o processo de tomada de decisão, tanto por parte do poder público, quanto da comunidade, permitindo uma gestão ambiental mais eficiente e a melhoria da saúde e qualidade de vida da população.
APA, Harvard, Vancouver, ISO, and other styles
9

Izani Abidin, Mohamad Izani Zainal, Samad Alkhalidi, and Aishah Razak. "Utilizing VR/AR for Interior Design Program." In ICNCC 2020: 2020 The 9th International Conference on Networks, Communication and Computing. New York, NY, USA: ACM, 2020. http://dx.doi.org/10.1145/3447654.3447656.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

RAMOS, A. F. X., I. Q. MARINHO, and V. V. MURATA. "PREVISÃO DA QUALIDADE DO AR ATRAVÉS DO SOFTWARE CAL3QHC." In XI Congresso Brasileiro de Engenharia Química em Iniciação Científica. São Paulo: Editora Edgard Blücher, 2015. http://dx.doi.org/10.5151/chemeng-cobeqic2015-463-34088-263622.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Reports on the topic "Qualidade do ar interior"

1

CARLSON, A. B. Design analysis report for the 244-AR vault Interim Stabilization interior transfer system. Office of Scientific and Technical Information (OSTI), December 2002. http://dx.doi.org/10.2172/808836.

Full text
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography