Dissertations / Theses on the topic 'Radiation measuring instruments'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the top 25 dissertations / theses for your research on the topic 'Radiation measuring instruments.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.
Farrell, K. W. "Investigation of the accuracy of array radiometry for measuring pulsed radiation sources /." Online version of thesis, 1987. http://hdl.handle.net/1850/9665.
Full textVIVOLO, VITOR. "Aplicacao de metodologia de testes de desempenho para monitores portateis de radiacao." reponame:Repositório Institucional do IPEN, 2000. http://repositorio.ipen.br:8080/xmlui/handle/123456789/10840.
Full textMade available in DSpace on 2014-10-09T13:57:07Z (GMT). No. of bitstreams: 1 07009.pdf: 4378283 bytes, checksum: 79cafd4e124d9349d8fbb819d59b5959 (MD5)
Dissertacao (Mestrado)
IPEN/D
Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
LUCENA, RODRIGO F. de. "Implantacao de um programa de controle de qualidade em equipamentos de raios X por meio de medidores nao invasivos." reponame:Repositório Institucional do IPEN, 2010. http://repositorio.ipen.br:8080/xmlui/handle/123456789/9571.
Full textMade available in DSpace on 2014-10-09T14:01:44Z (GMT). No. of bitstreams: 0
Dissertacao (Mestrado)
IPEN/D
Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
OLIVEIRA, ELIANE C. "Estabelecimentos de campos padroes de raios-x de energias baixas, nivel de radioprotecao, para calibracao de instrumentos." reponame:Repositório Institucional do IPEN, 1995. http://repositorio.ipen.br:8080/xmlui/handle/123456789/10666.
Full textMade available in DSpace on 2014-10-09T14:08:16Z (GMT). No. of bitstreams: 1 04995.pdf: 5445247 bytes, checksum: 94d30480189048c6bb746a9db426ad86 (MD5)
Dissertacao(Mestrado)
IPEN/D
Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
MIRANDA, JUREMA A. de. "Desenvolvimento de uma metodologia para a calibracao de instrumentos de medida utilizados no controle de qualidade em radiodiagnostico intervencional." reponame:Repositório Institucional do IPEN, 2009. http://repositorio.ipen.br:8080/xmlui/handle/123456789/9407.
Full textMade available in DSpace on 2014-10-09T14:06:29Z (GMT). No. of bitstreams: 0
Dissertacao (Mestrado)
IPEN/D
Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
ROS, RENATO A. "Metodologia de controle de qualidade de equipamentos de raios x (nivel diagnostico) utilizados em calibracao de instrumentos." reponame:Repositório Institucional do IPEN, 2000. http://repositorio.ipen.br:8080/xmlui/handle/123456789/10803.
Full textMade available in DSpace on 2014-10-09T14:07:52Z (GMT). No. of bitstreams: 1 07071.pdf: 5827883 bytes, checksum: 3d1bd075be2e6283f7d961fc597f6d59 (MD5)
Dissertacao (Mestrado)
IPEN/D
Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
FERREIRA, DANILO C. "Desenvolvimento e calibração de um sistema dosimétrico de rotina em processamento por irradiação." reponame:Repositório Institucional do IPEN, 2013. http://repositorio.ipen.br:8080/xmlui/handle/123456789/10593.
Full textMade available in DSpace on 2014-10-09T14:00:08Z (GMT). No. of bitstreams: 0
Tese (Doutoramento)
IPEN/T
Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
DAMATTO, WILLIAN B. "Desenvolvimento de uma metodologia de avaliação de medidores portáteis de radiação em altas taxas de kerma no ar." reponame:Repositório Institucional do IPEN, 2015. http://repositorio.ipen.br:8080/xmlui/handle/123456789/26079.
Full textMade available in DSpace on 2016-04-08T12:38:10Z (GMT). No. of bitstreams: 0
Dissertação (Mestrado em Tecnologia Nuclear)
IPEN/D
Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
VIVOLO, VITOR. "Desenvolvimento de um sistema de referencia para determinacao do equivalente de dose pessoal e da constancia de feixes de radiacao X." reponame:Repositório Institucional do IPEN, 2006. http://repositorio.ipen.br:8080/xmlui/handle/123456789/11379.
Full textMade available in DSpace on 2014-10-09T14:05:52Z (GMT). No. of bitstreams: 0
Tese (Doutoramento)
IPEN/T
Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
NOGUEIRA, MARIA do S. "Determinacao dos fatores de conversao de kerma no ar e de fluencia para o equivalente de dose ambiental para raios X gerados no intervalo de 50 kV subp a 125 kV subp." reponame:Repositório Institucional do IPEN, 1997. http://repositorio.ipen.br:8080/xmlui/handle/123456789/10491.
Full textMade available in DSpace on 2014-10-09T14:10:03Z (GMT). No. of bitstreams: 1 04674.pdf: 2960498 bytes, checksum: 31da12ce5904c3db2729e9982663d7fe (MD5)
Tese (Doutoramento)
IPEN/T
Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
Durrant, Paul Timothy. "Development of EPSILON : a gamma ray imaging system for the nuclear industry." Thesis, University of Southampton, 1999. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.368122.
Full textRosado, Paulo Henrique Gonçalves. "Determinação experimental dos coeficientes de conversão de Kerma no ar para o equivalente de dose pessoal, Hp(d), e fatores de retroespalhamento em feixes de raios-x diagnostico." CNEN - Centro de Desenvolvimento da Tecnologia Nuclear, Belo Horizonte, 2008. http://www.bdtd.cdtn.br//tde_busca/arquivo.php?codArquivo=86.
Full textTwo sets of quantities are import in radiological protection: the protection and operational quantities. Both sets can be related to basic physical quantities such as kerma through conversion coefficients. . For diagnostic x-ray beams the conversion coefficients and backscatter factors have not been determined yet, those parameters are need for calibrating dosimeters that will be used to determine the personal dose equivalent or the entrance skin dose. Conversion coefficients between air kerma and personal dose equivalent and backscatter factors were experimentally determined for the diagnostic x-ray qualities RQR and RQA recommended by the International Electrotechnical Commission (IEC). The air kerma in the phantom and the mean energy of the spectrum were measured for such purpose. Harshaw LiF-100H thermoluminescent dosemeters (TLD) were used for measurements after being calibrated against an 180 cm3 Radcal Corporation ionization chamber traceable to a reference laboratory. A 300 mm ×300 mm × 150 mm polymethilmethacrylate (PMMA) slab phantom was used for deep-dose measurements. Tl dosemeters were placed in the central axis of the x-ray beam at 5, 10, 15, 25 and 35 mm depth in the phantom upstream the beam direction Another required parameter for determining the conversion coefficients from was the mean energy of the x-ray spectrum. The spectroscopy of x-ray beams was done with a CdTe semiconductor detector that was calibrated with 133Ba, 241Am and 57Co radiation sources. Measurements of the x-ray spectra were carried out for all RQR and RQA IEC qualities. Corrections due to the detector intrinsic efficiency, total energy absorption, escape fraction of the characteristic x-rays, Compton effect and attenuation in the detector were done aiming an the accurate determination of the mean energy. Measured x-ray spectra were corrected with the stripping method by using these response functions. The typical combined standard uncertainties of conversion coefficients and backscatter factors were 12% and 6% respectively.
TOBIAS, CARMEN C. B. "Detectores gasosos de eletrodo resistivo: regime estacionario e transitorio de funcionamento." reponame:Repositório Institucional do IPEN, 2004. http://repositorio.ipen.br:8080/xmlui/handle/123456789/11235.
Full textMade available in DSpace on 2014-10-09T14:02:20Z (GMT). No. of bitstreams: 1 09811.pdf: 7739701 bytes, checksum: 322f7fce8713f27550b470eff5575b73 (MD5)
Tese (Doutoramento)
IPEN/T
Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
SAMPA, MARIA H. de O. "Desenvolvimento do processo de deposicao eletroforetica de boro em substratos de aluminio destinados a construcao de detectores de neutrons." reponame:Repositório Institucional do IPEN, 1988. http://repositorio.ipen.br:8080/xmlui/handle/123456789/9892.
Full textMade available in DSpace on 2014-10-09T14:09:09Z (GMT). No. of bitstreams: 1 03259.pdf: 2834364 bytes, checksum: fcbdf9e370a39ffdb27be573e65f253c (MD5)
Tese (Doutoramento)
IPEN/T
Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
CORREA, EDUARDO de L. "Metodologia de controle de qualidade e implantacao de campos padroes de radiacao X, nivel mamografia, seguindo a norma IEC 61267." reponame:Repositório Institucional do IPEN, 2010. http://repositorio.ipen.br:8080/xmlui/handle/123456789/9603.
Full textMade available in DSpace on 2014-10-09T13:56:01Z (GMT). No. of bitstreams: 0
Dissertacao (Mestrado)
IPEN/D
Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
POTIENS, MARIA da P. A. "Metodologia dosimetrica e sistema de referencia para radiacao x nivel diagnostico." reponame:Repositório Institucional do IPEN, 1999. http://repositorio.ipen.br:8080/xmlui/handle/123456789/10751.
Full textMade available in DSpace on 2014-10-09T14:09:51Z (GMT). No. of bitstreams: 1 06644.pdf: 6476949 bytes, checksum: 537fe5234ba74d48639417cebfe94231 (MD5)
Tese (Doutoramento)
IPEN/T
Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
GONCALVES, JOSEMARY A. C. "Pesquisas propriedades e aplicacoes de detectores de faisca em problemas de fisica nuclear de energia atomica." reponame:Repositório Institucional do IPEN, 1993. http://repositorio.ipen.br:8080/xmlui/handle/123456789/10321.
Full textMade available in DSpace on 2014-10-09T14:09:06Z (GMT). No. of bitstreams: 1 02029.pdf: 4740189 bytes, checksum: ff05d787c5ab98b675cc36bbe2b0c062 (MD5)
Tese (Doutoramento)
IPEN/T
Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
OLIVEIRA, ADRIANO dos S. "Análise compartimental e aspectos dosimétricos aplicados ao colesterol marcado com sup(3)H." reponame:Repositório Institucional do IPEN, 2015. http://repositorio.ipen.br:8080/xmlui/handle/123456789/25664.
Full textMade available in DSpace on 2016-02-03T11:46:20Z (GMT). No. of bitstreams: 0
Dissertação (Mestrado em Tecnologia Nuclear)
IPEN/D
Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
PUGLIESI, FABIO. "Caracterização do polímero durolon como detector de traços nucleares de estado sólido." reponame:Repositório Institucional do IPEN, 2008. http://repositorio.ipen.br:8080/xmlui/handle/123456789/11674.
Full textMade available in DSpace on 2014-10-09T14:07:20Z (GMT). No. of bitstreams: 0
Tese (Doutoramento)
IPEN/T
Instituto de Pesquisas Energéticas e Nucleares - IPEN/CNEN-SP
DOMIENIKAN, CLAUDIO. "Desenvolvimento de um espectrômetro de correlação angular gama-gama perturbada com seis detectores de BaF2 e estudo de interações hiperfinas em composto intermetálico LaMnSi2." reponame:Repositório Institucional do IPEN, 2016. http://repositorio.ipen.br:8080/xmlui/handle/123456789/26948.
Full textMade available in DSpace on 2016-12-22T16:42:56Z (GMT). No. of bitstreams: 0
Neste trabalho foi desenvolvido um Espectrômetro de Correlação Angular Gama- Gama Perturbada Diferencial em Tempo (CAP) constituído por seis detectores cintiladores de BaF2, para realização de medidas de interações hiperfinas (campo hiperfino magnético e gradiente de campo elétrico) em diversos materiais e propiciar estudos na área da física da matéria condensada. O espectrômetro desenvolvido possui um sistema de aquisição não convencional em comparação aos demais equipamentos destinados a medidas de CAP. Ao invés do tradicional Analisador Multicanal (MCA), este espectrômetro utiliza um sistema de aquisição de dados constituído, basicamente, por um Conversor Analógico Digital (ADC) rápido, uma placa digital (I/O) convencional e um roteador construído no laboratório de Interações Hiperfinas (LIH) do IPEN. Este versátil e eficiente sistema, controlado por um software também criado no LIH em LabVIEW, permite a geração simultânea de 30 espectros de coincidências γ - γ atrasadas, número superior em comparação aos 12 espectros do antigo espectrômetro de quatro detectores. Além de medidas de linearidade, resolução em tempo e tempo morto, o funcionamento e o desempenho do espectrômetro foram comprovados através de medidas de CAP utilizando os núcleos de prova 111In -> 111Cd e 181Hf -> 181Ta, cujos resultados são bem conhecidos da literatura. Foram feitas medidas de interação quadrupolar do 181Ta em háfnio metálico e do 111Cd em cádmio metálico, e de campo hiperfino magnético do 111Cd e do 181Ta em níquel. Os resultados destas medidas se mostraram em concordância com a literatura. Adicionalmente foram realizadas medidas inéditas de interações hiperfinas magnéticas no composto intermetálico LaMnSi2 utilizando os núcleos de prova 111Cd e 140Ce. As medidas foram realizadas na faixa de temperatura de 10 K a 400K. No caso das medidas utilizando a sonda 111In -> 111Cd, os resultados mostram uma variação do campo magnético com a temperatura que segue a função de Brillouin. Já no caso das medidas com o núcleo de prova 140La -> 140Ce, o resultado apresentou um comportamento anômalo do campo hiperfino em função de temperatura. Os resultados evidenciam uma forte hibridização da banda 4f do Ce com a banda 3d do Mn, fato verificado e estudado em trabalhos anteriores com compostos semelhantes.
Tese (Doutorado em Tecnologia Nuclear)
IPEN/T
Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP
MAIA, ANA F. "Padronização de feixes e metodologia dosimétrica em tomografia computadorizada." reponame:Repositório Institucional do IPEN, 2005. http://repositorio.ipen.br:8080/xmlui/handle/123456789/11291.
Full textMade available in DSpace on 2014-10-09T13:58:51Z (GMT). No. of bitstreams: 1 10890.pdf: 10562798 bytes, checksum: 063bd7e321751780a6d96cafecfe45bc (MD5)
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Tese (Doutoramento)
IPEN/T
Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
FAPESP:01/06837-2
Palmieri, Anderson Marcelli. "Desenvolvimento de sistema automatizado de baixo custo para coleta e armazenamento de dados de variáveis climáticas: aplicações no ambiente agrícola." Universidade de São Paulo, 2009. http://www.teses.usp.br/teses/disponiveis/11/11131/tde-18022010-142019/.
Full textClimate variables such as air temperature, air humidity and solar radiation have a significant impact on agricultural yield. These variables affect the production process, and have a considerable influence on final product prices. The objective of this research, therefore, was to develop a low-cost, automated system, based on the Basic Step 1 microcontroller, to collect and store climate data in a flash memory device with USB connection (pen drive). In addition, the system includes the Data Basic Software, developed to enable the user to visualize the data in a graphical user interface and to manipulate the data in a spreadsheet (EXCEL). The results demonstrated the viability of the automated system (Data-Basic), which worked with regularity and precision in measuring and storing continuous voltage signals from 3 sensors. The measured data from the air humidity and temperature sensors, HIH4000 and LM35, were reliable, showing the viability of the system, while the radiation sensor was fragile and required pre calibration before installation. The cost of mounting the equipment was approximately 50% of that of a portable data logger. The system is easy to maintain, allows for the replacement of elements such as the microcontroller (Basic Step 1) or the storage module (PenBS), and has external sensors which can be replaced if necessary. It is feasibility to use this tool because of its low production cost. However, for extended periods of data collection, it is recommended that an external battery be added to prevent data loss during power outages. During the installation process, precautions should be taken to prevent the oxidation of the sensors, which would result in measurement errors, directly affect the quality of data collected.
Charvat, Ales. "Etude, réalisation et caractérisation d'un spectromètre d'absorption intracavité à l'aide d'un laser Ti:Saphir." Université Joseph Fourier (Grenoble), 1994. http://www.theses.fr/1994GRE10223.
Full textLahbabi, Khalid. "Etude et realisation d'un dispositif de mesure, dans le spectre infrarouge, de l'emissivite des materiaux opaques." Paris 6, 1986. http://www.theses.fr/1986PA066115.
Full textChristoforou, Georges. "Conception de préamplificateurs intégrés pour fonctionnement à basse température et sous rayonnement intense." Université Joseph Fourier (Grenoble), 1998. http://www.theses.fr/1998GRE10031.
Full text