Contents
Academic literature on the topic 'Radio (Hueso)'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Radio (Hueso).'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Journal articles on the topic "Radio (Hueso)"
Renart, I., C. Gómez, N. Aparicio, I. Villalobos, and D. Lacroix. "Carpectomía proximal. Estudio por elementos finitos." Revista Iberoamericana de Cirugía de la Mano 39, no. 01 (May 2011): 022–31. http://dx.doi.org/10.1055/s-0037-1606786.
Full textAllende, Victoria, and Julio Javier Masquijo. "Pseudoartrosis congénita de antebrazo asociada a luxación de radio proximal: Tratamiento quirúrgico mediante antebrazo de un solo hueso. [Congenital forearm pseudoarthrosis associated with proximal radius dislocation: Surgical treatment using a single bone forearm.]." Revista de la Asociación Argentina de Ortopedia y Traumatología 82, no. 3 (July 28, 2017): 242. http://dx.doi.org/10.15417/420.
Full textMuratore, Alvaro, Gustavo Luis Gómez Rodríguez, Javier Dal Lago, Nicolás Robador, Gabriel Nazur, and Gabriel Clembosky. "Biomecánica de la fijación distal en fracturas extrarticulares de radio: tornillos versus pernos Estudio en modelos cadavéricos. [Biomechanics of distal fixation in distal radius fracture: screws versus smooth pegs. Study in cadaveric models.]." Revista de la Asociación Argentina de Ortopedia y Traumatología 80, no. 4 (November 19, 2015): 292. http://dx.doi.org/10.15417/353.
Full textHuamaní Mamani, Jorge Omar, Luis Cornejo Salazar, and Karen Manrique Ponce De León. "Prótesis implanto soportada sobre barra en maxilar reconstruido por injerto de peroné." Odontología Sanmarquina 8, no. 2 (May 14, 2014): 22. http://dx.doi.org/10.15381/os.v8i2.3142.
Full textRenart, I., C. Gómez, J. Pujals, and E. Gómez. "Artrodesis de muñeca con resección simultánea de la primera fila del carpo. Nuestra experiencia en la mano reumatoide." Revista Iberoamericana de Cirugía de la Mano 35, no. 02 (November 2007): 014–21. http://dx.doi.org/10.1055/s-0037-1606712.
Full textRenart, I., C. Gómez, J. Pujals, and J. Rodríguez. "Resección de la primera fila del carpo (Carpectomía Proximal)." Revista Iberoamericana de Cirugía de la Mano 33, no. 67 (November 2005): 022–30. http://dx.doi.org/10.1055/s-0037-1606674.
Full textAmigo Castañeda, Pavel, Maylin Rodríguez Díaz, Rubén Ariel Olivera León, and Pavel Alejandro Amigo Rodríguez. "Seudoartrosis por defecto óseo del antebrazo. A propósito de un caso." Anatomía Digital 4, no. 2 (April 5, 2021): 17–29. http://dx.doi.org/10.33262/anatomiadigital.v4i2.1614.
Full textReyna-Villasmil, Eduardo, Gabriel Mayner-Tresol, and Viorkis Pérez-Ortiz. "Metástasis cerebral de carcinoma de cuello uterino." Revista Peruana de Ginecología y Obstetricia 64, no. 1 (April 12, 2018): 113–16. http://dx.doi.org/10.31403/rpgo.v64i2067.
Full textAedo-Martín, Daniel, Sergio Alvarez, Isabel Vara-Patudo, and Javier Alonso-Hernández. "Fusión radiocubital en paciente con osteocondromatosis múltiple hereditaria." Revista Iberoamericana de Cirugía de la Mano 45, no. 01 (May 2017): 040–44. http://dx.doi.org/10.1055/s-0037-1602744.
Full textCortabarría, N., R. Graciano, M. Londinsky, T. Camarot, V. Franco, and L. Larrosa. "Lipoma como etiología del síndrome interóseo posterior. Presentación de un caso clínico." Revista Iberoamericana de Cirugía de la Mano 34, no. 01 (April 2006): 038–41. http://dx.doi.org/10.1055/s-0037-1606688.
Full textDissertations / Theses on the topic "Radio (Hueso)"
Toro, Aguilera Álvaro. "Síntesis de radio distal con placa volar. Influencia del bloqueo en el ángulo de los tornillos." Doctoral thesis, Universitat de Barcelona, 2014. http://hdl.handle.net/10803/283469.
Full textINTRODUCTION: Numerous plate-screw designs have been used for the treatment of distal radial fractures in the last years. To date, there is no evidence of clinical superiority or reducing complications between the fixed-angle locking and variable-angle locking screws. The aim of this study was to asses if variable-angle was superior to fixed-angle locking plate-screw with respect to complications and clinical outcomes. MATERIAL AND METHODS: 2 prospective cohorts of 40 patients each with a surgical distal radius fracture were studied. The first cohort was treated with a variable-angle locking plate-screw (PROLock Distal Radius Plate, I.T.S.) and the second one with a fixed-angle locking plate-screw (DVR DePuy Synthes). Both cohorts are statistically equal in order of age, sex, wrist side, complexity (Frykman’s classification) and radius size measured with Lister’s CT length. All patients had a minimum follow of 6 months after surgery and all were studied by CT-scan at that time. Radiological findings where measured by two radiologists specialized in musculoskeletal system. All data follows parametric criteria, Student’s t-test was performed for quantitative variables and chi-square test and fisher’s exact test for qualitatives. RESULTS: Variable-angle plate had dorsal protrusion in 17 cases (42.50%) and joint penetration in 3 cases (7.50%). It’s clinical repercussion was in 3 (7.50%) and 0 (0.00%) patients respectively. There was no statistical differences against fixed-angle plate with 16 dorsal protrusions (40.00%) and 2 joint penetrations (5.00%) with clinical implication in 6 (15.00%) and 0 (0.00%) respectively. Functional 6 months outcomes were of 82.250 points in Mayo Wrist score for the variable-angle plate and 81.875 points for the fixed-angle plate. CONCLUSION: Our results show that both devices had equivalent rate of dorsal and articular protrusion and functional outcomes. However, the radial height was statistically better preserved in the variable-angle plate (p=0.002). Fixed-angle plate had a higher rate of minor complications (p=0.012). Secondary objectives reflect a descriptive dorsal protrusion-risk study in order to distal radius size and screw hole plate position. Finally, an accurate surgical reduction or a 6 months loss of reduction, did not impact to short term functional outcomes.
Alba, Fernández Carmiña. "Ontogenetic study of the mechanical properties and architecture of the radius (appendicular bone) of two species of odontocetes Stenella coeruleoalba and Pontoporia blainvillei = Estudio ontogenético de las propiedades mecánicas y la arquitectura en el radio (hueso apendicular) de dos especies de odontocetos Stenella coeruleoalba y Pontoporia blainvillei." Doctoral thesis, Universitat de Barcelona, 2016. http://hdl.handle.net/10803/386444.
Full text