To see the other types of publications on this topic, follow the link: Radioisotope method.

Dissertations / Theses on the topic 'Radioisotope method'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 34 dissertations / theses for your research on the topic 'Radioisotope method.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

Rodgers, Joseph J. "Radiochromic film dosimetry system for endovascular brachytherapy source calibration : a method and its uncertainties." Thesis, Georgia Institute of Technology, 1996. http://hdl.handle.net/1853/16468.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Shrestha, Santosh Kumar Physical Environmental &amp Mathematical Sciences Australian Defence Force Academy UNSW. "Characterisation of indium nitride films with swift ions and radioisotope probes." Awarded by:University of New South Wales - Australian Defence Force Academy. School of Physical, Environmental and Mathematical Sciences, 2005. http://handle.unsw.edu.au/1959.4/38734.

Full text
Abstract:
[Formulae and special characters can not be reproduced here. Please see the pdf version of the Abstract for an accurate reproduction.] Indium nitride is an important III-V nitride semiconductor with many potential applications such as in high frequency transistors, laser diodes and photo voltaic cells. The mobility and peak drift velocity of this material are predicted to be extremely high and superior to that of gallium nitride. However, many material properties such as the origin of the n-type conductivity and the electronic band gap are not well understood. Moreover, there is limited inform
APA, Harvard, Vancouver, ISO, and other styles
3

Kelm, Robert S. "In-water neutron and gamma dose determination for a new Cf-252 brachytherapy source." Thesis, Atlanta, Ga. : Georgia Institute of Technology, 2009. http://hdl.handle.net/1853/28121.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

PIUVEZAM, FILHO HELIO. "Estudo de um sistema de coincidência 4-pi-beta-gama para a medida absoluta de atividade de radionuclídeos empregando cintiladores plásticos." reponame:Repositório Institucional do IPEN, 2007. http://repositorio.ipen.br:8080/xmlui/handle/123456789/11507.

Full text
Abstract:
Made available in DSpace on 2014-10-09T12:52:39Z (GMT). No. of bitstreams: 0<br>Made available in DSpace on 2014-10-09T14:02:17Z (GMT). No. of bitstreams: 0<br>Dissertação (Mestrado)<br>IPEN/D<br>Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP
APA, Harvard, Vancouver, ISO, and other styles
5

White, Carla A. "Design of an experimental irradiation facility based on 50-mg ²⁵²Cf for ¹⁰B-enhanced ²⁵²Cf brachytherapy." Thesis, Georgia Institute of Technology, 2000. http://hdl.handle.net/1853/17303.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

PERES, ANA C. "Modelo para o estabelecimento de valores orientadores para elementos radioativos no solo." reponame:Repositório Institucional do IPEN, 2007. http://repositorio.ipen.br:8080/xmlui/handle/123456789/11591.

Full text
Abstract:
Made available in DSpace on 2014-10-09T12:53:36Z (GMT). No. of bitstreams: 0<br>Made available in DSpace on 2014-10-09T14:08:08Z (GMT). No. of bitstreams: 0<br>Tese (Doutoramento)<br>IPEN/T<br>Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP
APA, Harvard, Vancouver, ISO, and other styles
7

Bannon, Elizabeth. "Dosimetric characterization of elongated brachytherapy sources using Monte Carlo methods." Thesis, Georgia Institute of Technology, 2010. http://hdl.handle.net/1853/33923.

Full text
Abstract:
Current brachytherapy treatment planning systems are unable to accurately calculate dose distributions in the vicinity of brachytherapy sources having active lengths much greater than 5 mm. While low dose-rate ¹³⁷Cs sources are dosimetrically characterized using antiquated along-away tables with simple linear-linear interpolation errors in dose calculation exceeding 30% occur due to algorithm inadequacy. The method presented in this thesis permits dosimetric characterization of elongated brachytherapy sources with active lengths 0 < L < 10 cm for implementation on an FDA-approved clinical TPS.
APA, Harvard, Vancouver, ISO, and other styles
8

BRITO, ANDREIA B. de. "Determinação da taxa de desintegração de Tc-99m e In-111 em sistemas de coincidências." reponame:Repositório Institucional do IPEN, 2011. http://repositorio.ipen.br:8080/xmlui/handle/123456789/10047.

Full text
Abstract:
Made available in DSpace on 2014-10-09T12:34:11Z (GMT). No. of bitstreams: 0<br>Made available in DSpace on 2014-10-09T14:06:46Z (GMT). No. of bitstreams: 0<br>Dissertação (Mestrado)<br>IPEN/D<br>Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
APA, Harvard, Vancouver, ISO, and other styles
9

MATOS, IZABELA T. de. "Padronização dos radionuclídeos F-18 e In-111 e determinação dos coeficientes de conversão interna total para o In-111 em sistema de coincidência por software." reponame:Repositório Institucional do IPEN, 2014. http://repositorio.ipen.br:8080/xmlui/handle/123456789/10615.

Full text
Abstract:
Made available in DSpace on 2014-10-09T12:42:28Z (GMT). No. of bitstreams: 0<br>Made available in DSpace on 2014-10-09T14:02:00Z (GMT). No. of bitstreams: 0<br>Dissertação (Mestrado)<br>IPEN/D<br>Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
APA, Harvard, Vancouver, ISO, and other styles
10

Situ, Peter D. "Voxel based beta particle dosimetry methods in mice." Diss., Columbia, Mo. : University of Missouri-Columbia, 2006. http://hdl.handle.net/10355/5897.

Full text
Abstract:
Thesis (Ph. D.)--University of Missouri-Columbia, 2006.<br>The entire dissertation/thesis text is included in the research.pdf file; the official abstract appears in the short.pdf file (which also appears in the research.pdf); a non-technical general description, or public abstract, appears in the public.pdf file. Title from title screen of research.pdf file (viewed on August 14, 2007) Vita. Includes bibliographical references.
APA, Harvard, Vancouver, ISO, and other styles
11

Long, Deirdré. "An analysis of dose effectiveness and incidence of late rectal complications of high dose-rate brachytherapy in the radical treatment of cervical cancer." Thesis, Bloemfontein : Central University of Technology, Free State, 2007. http://hdl.handle.net/11462/94.

Full text
APA, Harvard, Vancouver, ISO, and other styles
12

Посухов, Олександр Сергійович, Александр Сергеевич Посухов та Oleksandr Serhiiovych Posukhov. "Интегрированная информационно-аналитическая система для исследования диффузии в композиционных материалах при радиационных и механических нагрузках". Thesis, Харьковский нац. ун-т им. В.Н. Каразина, 2012. http://essuir.sumdu.edu.ua/handle/123456789/30331.

Full text
Abstract:
Дисертація присвячена створенню апаратно-програмного комплексу для дослідження параметрів дифузії в металах та сплавах з метою підвищення швидкості визначення параметрів дифузії і для подальшої оцінки структурної стабільності матеріалів, а також можливості їх застосування в жорстких умовах експлуатації. Розроблено феноменологічні моделі прискорення дифузії в композиційних матеріалах за умови механічного та радіаційного навантаження, які найбільш повно враховують вплив наведених дефектів. Створено апаратно-програмний комплекс для визначення параметрів дифузії в металах та сплавах при зовні
APA, Harvard, Vancouver, ISO, and other styles
13

Dess, Brian William. "Signal processing and pattern recognition methods for the remote, airborne detection of radioisotopes by gamma-ray spectroscopy." Diss., University of Iowa, 2016. https://ir.uiowa.edu/etd/2068.

Full text
Abstract:
The U.S Environmental Protection Agency (USEPA) Airborne Spectral Photometric Environmental Collection Technology (ASPECT) program is designed in part to provide first responders with radiological mapping of potentially hazardous locations. This program utilizes an aircraft fitted with a gamma-ray spectrometer capable of remote detection of radioisotopes. The challenges present in detecting a radioisotope signal remotely are strongly tied to the signal-to-noise ratio of the collected gamma-ray spectra and the specific sign
APA, Harvard, Vancouver, ISO, and other styles
14

MOREIRA, DENISE S. "Padronização dos radionuclídeos multi-emissores gama sup(166m)Ho e sup(72)Ga e determinação de suas intensidades gama por decaimento." reponame:Repositório Institucional do IPEN, 2005. http://repositorio.ipen.br:8080/xmlui/handle/123456789/11295.

Full text
Abstract:
Made available in DSpace on 2014-10-09T12:50:25Z (GMT). No. of bitstreams: 0<br>Made available in DSpace on 2014-10-09T13:58:46Z (GMT). No. of bitstreams: 1 10894.pdf: 5952992 bytes, checksum: e3d25a70f800a8a854f7dc99848817ad (MD5)<br>Tese (Doutoramento)<br>IPEN/T<br>Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
APA, Harvard, Vancouver, ISO, and other styles
15

Duringer, Cathy. "La contamination de la thyroide par les radioisotopes de l'iode en cas d'accident nucleaire : methodes de prevention." Université Louis Pasteur (Strasbourg) (1971-2008), 1989. http://www.theses.fr/1989STR1M007.

Full text
APA, Harvard, Vancouver, ISO, and other styles
16

OLIVEIRA, TIAGO B. de. "Estudo dos parâmetros dosimétricos de sementes de Iodo-125 desenvolvidas pelo IPEN-CNEN/SP utilizadas em braquiterapia por simulação computacional pelo método de Monte Carlo." reponame:Repositório Institucional do IPEN, 2016. http://repositorio.ipen.br:8080/xmlui/handle/123456789/26392.

Full text
Abstract:
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2016-06-22T14:06:41Z No. of bitstreams: 0<br>Made available in DSpace on 2016-06-22T14:06:41Z (GMT). No. of bitstreams: 0<br>Dissertação (Mestrado em Tecnologia Nuclear)<br>IPEN/D<br>Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
APA, Harvard, Vancouver, ISO, and other styles
17

LAVRAS, WILSON de O. "Desenvolvimento de metodos de medida de atividade de radionuclideos utilizados em medicina nuclear - aplicacao na padronizacao do sup(51) Cr e sup(153) Sm." reponame:Repositório Institucional do IPEN, 2002. http://repositorio.ipen.br:8080/xmlui/handle/123456789/11061.

Full text
Abstract:
Made available in DSpace on 2014-10-09T12:47:40Z (GMT). No. of bitstreams: 0<br>Made available in DSpace on 2014-10-09T14:06:39Z (GMT). No. of bitstreams: 1 08346.pdf: 3889708 bytes, checksum: 998810087525503d37c9b42eac89fcec (MD5)<br>Dissertacao (Mestrado)<br>IPEN/D<br>Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
APA, Harvard, Vancouver, ISO, and other styles
18

Hedtjärn, Håkan. "Dosimetry in brachytherapy : application of the Monte Carlo method to single source dosimetry and use of correlated sampling for accelerated dose calculations /." Linköping : Univ, 2003. http://www.bibl.liu.se/liupubl/disp/disp2003/med790s.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
19

KOSKINAS, MARINA F. "Desenvolvimento de um sistema de coincidencia para a medida absoluta da atividade de radionuclideos empregando detectores de barreira de superficie." reponame:Repositório Institucional do IPEN, 1988. http://repositorio.ipen.br:8080/xmlui/handle/123456789/9896.

Full text
Abstract:
Made available in DSpace on 2014-10-09T12:32:34Z (GMT). No. of bitstreams: 0<br>Made available in DSpace on 2014-10-09T14:09:11Z (GMT). No. of bitstreams: 1 03265.pdf: 2027580 bytes, checksum: bfb6b3f05e4a4d0ace77d6c9a4d3aa59 (MD5)<br>Tese (Doutoramento)<br>IPEN/T<br>Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
APA, Harvard, Vancouver, ISO, and other styles
20

PONGE-FERREIRA, CLAUDIA R. P. "Padronização dos radionuclídeos sup(45)Ca, sup(137)Cs e sup(204)Tl pelo metodo do tracador utilizando sistema de coincidência 4 pi beta-gama." reponame:Repositório Institucional do IPEN, 2005. http://repositorio.ipen.br:8080/xmlui/handle/123456789/11287.

Full text
Abstract:
Made available in DSpace on 2014-10-09T12:50:19Z (GMT). No. of bitstreams: 0<br>Made available in DSpace on 2014-10-09T14:02:41Z (GMT). No. of bitstreams: 1 10886.pdf: 3145053 bytes, checksum: de92a5b14e97d88724cc81c6e671029b (MD5)<br>Dissertação (Mestrado)<br>IPEN/D<br>Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
APA, Harvard, Vancouver, ISO, and other styles
21

KUZNETSOVA, MARIA. "Medida absoluta da atividade de 14C pelos métodos CIEMAT/NIST, TDCR e em sistema de coincidência 4πβ-γ". reponame:Repositório Institucional do IPEN, 2016. http://repositorio.ipen.br:8080/xmlui/handle/123456789/27138.

Full text
Abstract:
Submitted by Maria Eneide de Souza Araujo (mearaujo@ipen.br) on 2017-03-10T16:38:03Z No. of bitstreams: 0<br>Made available in DSpace on 2017-03-10T16:38:03Z (GMT). No. of bitstreams: 0<br>Neste trabalho foi padronizada uma solução de 14C emissor beta puro com energia máxima de 156 keV, por meio de três diferentes métodos: CIEMAT/NIST e TDCR (triple-to-double coincidence ratio) em sistemas de cintilação líquida e pelo método do traçador, em sistema de coincidências 4&pi;&beta;-&gamma;. O sistema de cintilação líquida TRICARB, equipado com dois tubos fotomultiplicadores, foi usado para aplicaç
APA, Harvard, Vancouver, ISO, and other styles
22

TONGU, MARGARETH L. O. "Aplicacao do metodo de Monte Carlo na padronizacao de radionuclideos emissores de positrons." reponame:Repositório Institucional do IPEN, 2009. http://repositorio.ipen.br:8080/xmlui/handle/123456789/9467.

Full text
Abstract:
Made available in DSpace on 2014-10-09T12:27:03Z (GMT). No. of bitstreams: 0<br>Made available in DSpace on 2014-10-09T13:56:05Z (GMT). No. of bitstreams: 0<br>Dissertacao (Mestrado)<br>IPEN/D<br>Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
APA, Harvard, Vancouver, ISO, and other styles
23

TAKEDA, MAURO N. "Determinacao da correcao para o efeito de soma em cascata para espectrometros de HPGe pelo metodo de Monte Carlo." reponame:Repositório Institucional do IPEN, 2001. http://repositorio.ipen.br:8080/xmlui/handle/123456789/10916.

Full text
Abstract:
Made available in DSpace on 2014-10-09T12:45:30Z (GMT). No. of bitstreams: 0<br>Made available in DSpace on 2014-10-09T14:08:54Z (GMT). No. of bitstreams: 1 07154.pdf: 3791774 bytes, checksum: 92eea1762bc835526d152a1486fefa30 (MD5)<br>Dissertacao (Mestrado)<br>IPEN/D<br>Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
APA, Harvard, Vancouver, ISO, and other styles
24

BACCARELLI, AIDA M. "Sistema primario por coincidencias 4 pi beta-gama para a padronizacao de radionuclideos empregando cintiladores plasticos." reponame:Repositório Institucional do IPEN, 2003. http://repositorio.ipen.br:8080/xmlui/handle/123456789/11125.

Full text
Abstract:
Made available in DSpace on 2014-10-09T12:48:40Z (GMT). No. of bitstreams: 0<br>Made available in DSpace on 2014-10-09T13:59:57Z (GMT). No. of bitstreams: 1 09020.pdf: 3988111 bytes, checksum: 2604028ac5be423a7b85b745a959fb86 (MD5)<br>Tese (Doutoramento)<br>IPEN/T<br>Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
APA, Harvard, Vancouver, ISO, and other styles
25

LACERDA, FLAVIO W. "Padronização de sup(68)Ga em sistema de coincidências 4pß-?" reponame:Repositório Institucional do IPEN, 2013. http://repositorio.ipen.br:8080/xmlui/handle/123456789/10211.

Full text
Abstract:
Made available in DSpace on 2014-10-09T12:36:04Z (GMT). No. of bitstreams: 0<br>Made available in DSpace on 2014-10-09T13:59:49Z (GMT). No. of bitstreams: 0<br>Dissertação (Mestrado)<br>IPEN/D<br>Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
APA, Harvard, Vancouver, ISO, and other styles
26

TOLEDO, FABIO de. "Desenvolvimento de um sistema eletronico com registro simultaneo de amplitude e instante de ocorrencias dos pulsos, aplicado ao metodo de coincidencias 4'pi''beta''gama'." reponame:Repositório Institucional do IPEN, 2009. http://repositorio.ipen.br:8080/xmlui/handle/123456789/9473.

Full text
Abstract:
Made available in DSpace on 2014-10-09T12:27:07Z (GMT). No. of bitstreams: 0<br>Made available in DSpace on 2014-10-09T14:03:20Z (GMT). No. of bitstreams: 0<br>Dissertacao (Mestrado)<br>IPEN/D<br>Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
APA, Harvard, Vancouver, ISO, and other styles
27

Mouadili, Ahmed. "Etudes d'applications nouvelles d'un cyclotron : methodes originales de productionde radioisotopes de grande purete (#1#2#7xe, #5#7co, #5#6co et #7be) : dosage precis des traces de fluor dans l'email dentaire par activation." Orléans, 1989. http://www.theses.fr/1989ORLE2020.

Full text
Abstract:
Ce travail porte sur deux nouvelles applications de faisceaux de particules chargees produits au cyclotron du centre d'etudes et de recherches par irradiation (c. E. R. I. -cnrs a orleans). Dans une premiere partie, nous presentons les donnees fondamentales relatives a l'interaction des particules chargees et des neutrons avec la matiere ainsi qu'une breve description des dispositifs experimentaux que nous avons utilises. Nous donnons aussi les bases physiques de l'activation par neutrons rapides et les techniques de calcul des rendements de production d'un radioisotope a partir d'une cible ir
APA, Harvard, Vancouver, ISO, and other styles
28

BRANCACCIO, FRANCO. "Metodologia de aquisição de dados e análise por software, para sistemas de coincidências 4pß-? e sua aplicação na padronização de radionuclídeos, com ênfase em transições metaestáveis." reponame:Repositório Institucional do IPEN, 2013. http://repositorio.ipen.br:8080/xmlui/handle/123456789/10559.

Full text
Abstract:
Made available in DSpace on 2014-10-09T12:41:56Z (GMT). No. of bitstreams: 0<br>Made available in DSpace on 2014-10-09T14:04:33Z (GMT). No. of bitstreams: 0<br>Tese (Doutoramento)<br>IPEN/T<br>Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
APA, Harvard, Vancouver, ISO, and other styles
29

HILARIO, KATIA A. F. "Desenvolvimento de metodos de medida de atividade empregando sistemas de coincidencia para radionuclideos que desintegram pela dupla emissao beta sup(-) - beta sup(+) / captura eletronica - aplicacao na padronizacao do sup(192)Ir, sup(152)Eu e sup (186) Re." reponame:Repositório Institucional do IPEN, 2002. http://repositorio.ipen.br:8080/xmlui/handle/123456789/11018.

Full text
Abstract:
Made available in DSpace on 2014-10-09T12:47:00Z (GMT). No. of bitstreams: 0<br>Made available in DSpace on 2014-10-09T14:10:33Z (GMT). No. of bitstreams: 1 07614.pdf: 6594444 bytes, checksum: 0bd72d3764d638a649ad00b67ff5aa44 (MD5)<br>Tese (Doutoramento)<br>IPEN/T<br>Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
APA, Harvard, Vancouver, ISO, and other styles
30

Thierry, Raphaël. "Correction de l'atténuation et de la réponse géométrique d'un détecteur en tomographie d'émission sur colis de déchets nucléaires." Phd thesis, Université Joseph Fourier (Grenoble), 1999. http://tel.archives-ouvertes.fr/tel-00004856.

Full text
Abstract:
La tomographie d'émission multiphotonique est une technique de contrôle non destructif appliquée au contrôle des colis de déchets radioactifs. Les rayonnements gammas émis sont détectés sur la gamme [50 keV, 2 MeV] par un germanium hyper pur, de haute résolution en énergie, ce qui permet d'établir une carte détaillée des radioéléments contenus dans le colis. A partir des différents points de mesures situés dans un plan transaxial au colis, un algorithme de reconstruction permet d'estimer la distribution de l'activité. Une modélisation algébrique du processus a été développée afin de pouvoir co
APA, Harvard, Vancouver, ISO, and other styles
31

Badelli, Juliana do Carmo. "Desenvolvimento de phantom de mama para estudo de imagens por contraste de fase." Universidade Tecnológica Federal do Paraná, 2017. http://repositorio.utfpr.edu.br/jspui/handle/1/2864.

Full text
Abstract:
CAPES<br>Em vista do grande número de casos de câncer de mama e sua crescente taxa de incidência, novas técnicas de imagem estão sendo estudadas. No intuito de proporcionar melhores condições de visualização e detecção dessa doença, em complemento às informações obtidas por mamografia, as técnicas de imagem por contraste de fase vêm sendo investigadas. Assim, o objetivo do presente estudo, foi desenvolver um phantom de mama para aplicação em imagens por contraste de fase. Este phantom, é um cilindro com algumas inserções preenchidas por materiais equivalentes a tecidos mamários normais e patol
APA, Harvard, Vancouver, ISO, and other styles
32

Sawicka, Joanna. "Cooling methods to treat capture-induced hyperthermia in blesbok (Damaliscus dorcas phillipsi)." Thesis, 2011. http://hdl.handle.net/10539/10884.

Full text
Abstract:
MSc., Faculty of Science, University of the Witwatersrand, 2011<br>Wild animals are captured for management, health, translocation and research purposes. Capture is an unnaturally stressful event, which may result in morbidity or mortality. An attributing cause of the morbidity and mortality is capture-induced hyperthermia; the larger the magnitude and the longer the duration of this captured-induced hyperthermia, the greater the likely risk to the animal. The most common practice currently used in the field to lower body temperature is to douse hyperthermic animals with water. However, the wa
APA, Harvard, Vancouver, ISO, and other styles
33

Miles, Todd L. "Monte Carlo uncertainty reliability and isotope production calculations for a fast reactor." Thesis, 1991. http://hdl.handle.net/1957/36711.

Full text
Abstract:
With the advent of more powerful, less expensive computing resources, more and more attention is being given to Monte Carlo techniques in design application. In many circles, stochastic solutions are considered the next best thing to experimental data. Statistical uncertainties in Monte Carlo calculations are typically determined by the first and second moments of the tally. For certain types of calculations, there is concern that the uncertainty estimate is significantly non-conservative. This is typically seen in reactor eigenvalue problems where the uncertainty estimate is aggravated by the
APA, Harvard, Vancouver, ISO, and other styles
34

Genu, Aurelia Khanyiswa. "Radionuclide liquid waste treatment of 68[superscript]Ge by graphene oxide based nanomaterials." Diss., 2019. http://hdl.handle.net/10500/25715.

Full text
Abstract:
Radionuclide liquid wastes generated from nuclear facilities can affect humans and the environment, thus substantial attention for their safe management has been received worldwide. Treatment of radionuclide liquid wastes is an important step in its management. In the present work, new composite nanomaterials, graphene oxide base nanomaterial (GO) are developed for treatment purpose. Graphene oxide (GO), one of the most graphene derivatives, its unique properties, such as chemical stability, hydrophilicity, large surface area and functional groups, make them able to form strong chemical bonds
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!