To see the other types of publications on this topic, follow the link: Reconductoring.

Journal articles on the topic 'Reconductoring'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 18 journal articles for your research on the topic 'Reconductoring.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse journal articles on a wide variety of disciplines and organise your bibliography correctly.

1

Iqbal, Muhammad. "The Use Of Temporary Towers To Optimize The Completion Of Reconductoring And Tower Replacement Of 150 Kv High Voltage Overhead Lines (SUTT)." Return : Study of Management, Economic and Bussines 2, no. 7 (2023): 649–58. http://dx.doi.org/10.57096/return.v2i7.121.

Full text
Abstract:
Transmission lines play an important role in the successful and stable operation and distribution of power grids both for power evacuation from power plants and as a link from one Substation to another. The construction of new transmission lines as a form of meeting high electricity needs in the current era of Globalization has many obstacles, both in terms of rejection from residents, expensive licensing arrangements, and very expensive investment costs. Reconductoring is one of the methods of increasing transmission capacity at minimum cost with an adequate level of quality and reliability.
APA, Harvard, Vancouver, ISO, and other styles
2

Rohmanita Duanaputri, Ahmad Hermawan, and Zulvina Arifah. "Analisis Aliran Daya Reconductoring Saluran Transmisi Paiton Kraksaan-Probolinggo 150 kV Terhadap Saluran Yang Terimbas." Elposys: Jurnal Sistem Kelistrikan 9, no. 2 (2023): 64–69. http://dx.doi.org/10.33795/elposys.v9i2.618.

Full text
Abstract:
Provision of quality and sufficient electrical energy is something that must be done by PT. PLN (Persero). Based on data from PT. PLN (Persero), carried out work on replacing conductors on the Paiton – Kraksaan – Probolinggo transmission line from the TACSR 330 mm2 conductor with KHA 1190 A to 2xACCC/TW Copenhagen with KHA 2016 A. Reconductoring work is one of the efforts to uprating the transmission line by considering increasing load requirements. This reconductoring is carried out using the open circuit method or a total blackout in a circuit where the conductor is being replaced by taking
APA, Harvard, Vancouver, ISO, and other styles
3

Goli, Preetham, Kiran Jasthi, Srinivasa Rao Gampa, et al. "Electric Vehicle Charging Load Allocation at Residential Locations Utilizing the Energy Savings Gained by Optimal Network Reconductoring." Smart Cities 5, no. 1 (2022): 177–205. http://dx.doi.org/10.3390/smartcities5010012.

Full text
Abstract:
In this study, a two-stage methodology based on the energy savings gained by optimal network reconductoring was developed for the sizing and allocation of electric vehicle (EV) charging load at the residential locations in urban distribution systems. During the first stage, the Flower Pollination Algorithm (FPA) was applied to minimize the annual energy losses of the radial distribution system through optimum network reconductoring. A multi-objective function was formulated to minimize investment, peak loss, and annual energy loss costs at different load factors. The results obtained with the
APA, Harvard, Vancouver, ISO, and other styles
4

Kramer, David. "Advanced conductors could double power flows on the grid." Physics Today 77, no. 6 (2024): 21–23. http://dx.doi.org/10.1063/pt.myxz.pgmk.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Kopsidas, Konstantinos, and Simon M. Rowland. "A Performance Analysis of Reconductoring an Overhead Line Structure." IEEE Transactions on Power Delivery 24, no. 4 (2009): 2248–56. http://dx.doi.org/10.1109/tpwrd.2009.2021042.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Desprianto, Rahmad Yusuf, Suprihadi Prasetyono, and Dedy Kurnia Setiawan. "Studi Perencanaan Upgrade Transmisi Tegangan Tinggi 150 kV Perak-Ujung Menggunakan Konduktor HTLS (High Temeprature-Low Sag)." BERKALA SAINSTEK 5, no. 2 (2017): 118. http://dx.doi.org/10.19184/bst.v5i2.5704.

Full text
Abstract:
Saluran transmisi udara 150 kV pada umumnya menggunakan konduktor ACSR (Alumunium Conductor Steel Reinfoiced) yang mempunyai titik kerja suhu yang terbatas. Saluran transmisi udara akan mengalami titik jenuh seiring meningkatnya kebutuhan listrik. Dengan menyempitnya lahan dan masalah investasi maka saluran yang telah ada perlu dioptimalkan dengan melakukan reconductoring menggunakan konduktor HTLS (High Temperature Low Sag). Konduktor HTLS mempunyai titik kerja suhu yang tinggi dibandingkan konduktor ACSR. Penelitian ini bertujuan untuk meningkatkan kapasitas hantar arus serta untuk memenuhi
APA, Harvard, Vancouver, ISO, and other styles
7

Mr., Shivakumar L. N., Kirankumar G. R. Mr., and S. B. Shivakumar Dr. "Energy Audit on a Secondary Distribution System and Measures to Improve its Performance- A Case Study." Journal of Control and Instrumentation Engineering 4, no. 3 (2018): 15–18. https://doi.org/10.5281/zenodo.2343234.

Full text
Abstract:
<em>This paper presents the energy audit work carried out in low tension(LT) distribution network and various alternative proposals have been examined for the improvement of performance of the LT network. The network is simulated for a peak load using Mipower package to segregate technical and commercial losses. The various alternative proposals examined are relocating of DTC, addition of DTC, providing express line and reconductoring. The present worth analysis is also carried out for each alternative proposal.</em>
APA, Harvard, Vancouver, ISO, and other styles
8

H., M. Luqman, N. R. Baharom M., A. M. Jamail N., et al. "Conductor sag comparison for 132 kV overhead transmission line improvement in Malaysia." Bulletin of Electrical Engineering and Informatics 9, no. 1 (2020): 39–47. https://doi.org/10.11591/eei.v9i1.1863.

Full text
Abstract:
This paper presents conductor sag comparison for 132 kV overhead transmission line improvement in Malaysia. Increasing industrialization and population growth around the world demands higher electricity supply. Power generation has yet to decline but transmitting sufficient electricity to consumers is worrisome due to scarce land space occupied by rapid urbanization. Hence reconductoring method was chosen to improve existing 132 kV overhead transmission line in Malaysia. A group of selected conductors were chosen for comparison where the high temperature low sag conductor stood out the most pr
APA, Harvard, Vancouver, ISO, and other styles
9

Luqman, H. M., M. N. R. Baharom, N. A. M. Jamail, et al. "Conductor sag comparison for 132 kV overhead transmission line improvement in Malaysia." Bulletin of Electrical Engineering and Informatics 9, no. 1 (2020): 39–47. http://dx.doi.org/10.11591/eei.v9i1.1863.

Full text
Abstract:
This paper presents conductor sag comparison for 132 kV overhead transmission line improvement in Malaysia. Increasing industrialization and population growth around the world demands higher electricity supply. Power generation has yet to decline but transmitting sufficient electricity to consumers is worrisome due to scarce land space occupied by rapid urbanization. Hence reconductoring method was chosen to improve existing 132 kV overhead transmission line in Malaysia. A group of selected conductors were chosen for comparison where the high temperature low sag conductor stood out the most pr
APA, Harvard, Vancouver, ISO, and other styles
10

Legha, Mahdi Mozaffari, and Mohammad Mohammadi. "Aging Analysis and Reconductoring of Overhead Conductors for Radial Distribution Systems Using Genetic Algorithm." Journal of Electrical Engineering and Technology 9, no. 6 (2014): 2042–48. http://dx.doi.org/10.5370/jeet.2014.9.6.2042.

Full text
APA, Harvard, Vancouver, ISO, and other styles
11

Beryozkina, Svetlana. "Evaluation Study of Potential Use of Advanced Conductors in Transmission Line Projects." Energies 12, no. 5 (2019): 822. http://dx.doi.org/10.3390/en12050822.

Full text
Abstract:
Transmission networks recently faced new technical and economic challenges. The direct use of advanced technologies and modern methods could solve these issues. This paper discusses the potential application of straightforward technology such as high-temperature low-sag conductors (HTLScs) as an additional measure for the protection and effective operation of overhead power lines. An evaluation was conducted to determine an approach for selecting the cross-sectional area and type of conductor with respect to a fault current limitation. It showed the potential benefits of using HTLScs based on
APA, Harvard, Vancouver, ISO, and other styles
12

Franco, John F., Marcos J. Rider, Marina Lavorato, and Rubén Romero. "Optimal Conductor Size Selection and Reconductoring in Radial Distribution Systems Using a Mixed-Integer LP Approach." IEEE Transactions on Power Systems 28, no. 1 (2013): 10–20. http://dx.doi.org/10.1109/tpwrs.2012.2201263.

Full text
APA, Harvard, Vancouver, ISO, and other styles
13

Ahsan, Matiullah, Md Nor Ramdon Baharom, Ihsan Ullah Khalil, and Zainab Zainal. "Analysis of high-ampacity and low-sag conductors of 275 kV overhead transmission lines using reconductoring technique." Electric Power Systems Research 246 (September 2025): 111719. https://doi.org/10.1016/j.epsr.2025.111719.

Full text
APA, Harvard, Vancouver, ISO, and other styles
14

Huda, M. K., W. G. Ariastina, and I. W. Sukerayasa. "ANALISIS ALIRAN DAYA SISTEM KELISTRIKAN 150 KV BALI SAAT REKONDUKTORING SUTT GILIMANUK – NEGARA – ANTOSARI." Jurnal SPEKTRUM 7, no. 3 (2020): 83. http://dx.doi.org/10.24843/spektrum.2020.v07.i03.p11.

Full text
Abstract:
The need for electricity that is growing rapidly on the island of Bali, makes PT PLN (Persero)seek strategic steps in serving customers. Gilimanuk - Negara - Antosari Reconductoring SUTT150 kV is one of the efforts made by PT PLN (Persero) to improve the reliability of the BaliElectricity System which is used to overcome power evacuation problems in the future.Reconductoring goes through a one-month trip phase in each circuit. For this reason, a study isneeded to identify the electricity system readiness by using a power flow analysis simulatorapplication.The simulation is done by extinguishin
APA, Harvard, Vancouver, ISO, and other styles
15

Aschidamini, Gustavo L., Gederson A. da Cruz, Mariana Resener, Roberto C. Leborgne, and Luís A. Pereira. "A Framework for Reliability Assessment in Expansion Planning of Power Distribution Systems." Energies 15, no. 14 (2022): 5073. http://dx.doi.org/10.3390/en15145073.

Full text
Abstract:
This article proposes a framework that uses analytical assessment of reliability to guide the expansion planning of power distribution systems (PDS) considering reliability criteria. The framework allows the estimation of reliability indices with and without the execution of expansion projects, thus supporting the decision-making process on investments in expansion projects. In the analytical assessment of reliability, failure rates of zones and restoration times are calculated from past data of interruptions in the primary distribution network. In addition, the estimated reliability indices a
APA, Harvard, Vancouver, ISO, and other styles
16

Ciapessoni, Emanuele, Andrea Pitto, and Diego Cirio. "An Application of a Risk-Based Methodology to Anticipate Critical Situations Due to Extreme Weather Events in Transmission and Distribution Grids." Energies 14, no. 16 (2021): 4742. http://dx.doi.org/10.3390/en14164742.

Full text
Abstract:
Nowadays, distribution network operators are urged by regulatory authorities to reduce the load disruptions due to extreme weather events, i.e., to enhance network resilience: in particular, in Italy they are required to present a yearly plan (called “resilience plans”) describing the interventions aimed to improve network resilience. To this purpose, they need new methodologies and tools to assess the network resilience and to quantify the benefits of countermeasures. This paper proposes the application of a risk-based framework and tool to assess the impacts of extreme weather events in T&am
APA, Harvard, Vancouver, ISO, and other styles
17

Chojkiewicz, Emilia, Umed Paliwal, Nikit Abhyankar, et al. "Accelerating transmission capacity expansion by using advanced conductors in existing right-of-way." Proceedings of the National Academy of Sciences 121, no. 40 (2024). http://dx.doi.org/10.1073/pnas.2411207121.

Full text
Abstract:
As countries pursue decarbonization goals, the rapid expansion of transmission capacity for renewable energy (RE) integration poses a significant challenge due to hurdles such as permitting and cost allocation. However, we find that large-scale reconductoring with advanced composite-core conductors can cost-effectively double transmission capacity within existing right-of-way, with limited additional permitting. This strategy unlocks a high availability of increasingly economically viable RE resources in close proximity to the existing network. We implement reconductoring in a model of the US
APA, Harvard, Vancouver, ISO, and other styles
18

Gampa, Srinivasa Rao, Suresh Makkena, Preetham Goli, and Debapriya Das. "FPA Pareto optimality-based multiobjective approach for capacitor placement and reconductoring of urban distribution systems with solar DG units." International Journal of Ambient Energy, January 20, 2020, 1–17. http://dx.doi.org/10.1080/01430750.2020.1713887.

Full text
APA, Harvard, Vancouver, ISO, and other styles