Academic literature on the topic 'Reference partial discharge calibrator'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Reference partial discharge calibrator.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Reference partial discharge calibrator"

1

Khamlichi, Abderrahim, Fernando Garnacho, and Pascual Simón. "New Synthetic Partial Discharge Calibrator for Qualification of Partial Discharge Analyzers for Insulation Diagnosis of HVDC and HVAC Grids." Sensors 23, no. 13 (2023): 5955. http://dx.doi.org/10.3390/s23135955.

Full text
Abstract:
A synthetic partial discharge (PD) calibrator has been developed to qualify PD analyzers used for insulation diagnosis of HVAC and HVDC grids including cable systems, AIS, GIS, GIL, power transformers, and HVDC converters. PD analyzers that use high-frequency current transformers (HFCT) can be qualified by means of the metrological and diagnosis tests arranged in this calibrator. This synthetic PD calibrator can reproduce PD pulse trains of the same sequence as actual representative defects (cavity, surface, floating potential, corona, SF6 protrusion, SF6 jumping particles, bubbles in oil, etc
APA, Harvard, Vancouver, ISO, and other styles
2

ID, ORCID, J. Klüss, J. Hällström, et al. "Comparison of partial discharge (PD) calibrators from 0.1 pC to 10 nC." Metrologia 62, no. 1A (2025): 01002. https://doi.org/10.1088/0026-1394/62/1a/01002.

Full text
Abstract:
Main text High-voltage partial discharge (PD) tests require calibration of PD measurement systems using PD calibrators which provide known values of the apparent charge. A set of travelling reference calibrators was circulated among 14 participating laboratories and each laboratory reported apparent change and rise time measured using their own procedures. Comparison reference values (CRV) were calculated for each nominal charge level and calibrator and reasonable agreement of apparent charge calibration was reached. However, agreement of rise time measurements was unexpectedly poor. The scatt
APA, Harvard, Vancouver, ISO, and other styles
3

Siegel, Martin, Sebastian Coenen, Michael Beltle, et al. "Calibration Proposal for UHF Partial Discharge Measurements at Power Transformers." Energies 12, no. 16 (2019): 3058. http://dx.doi.org/10.3390/en12163058.

Full text
Abstract:
The continuous, non-intermitted service of electrical grids relies on the reliability of their assets, e.g., power transformers. Local insulation defects can result in serve failures such as breakdowns with severe subsequent costs. The prevention of such events is crucial. Hence, partial discharge (PD) activity at power transformers is evaluated directly in the factory before shipment. Additionally, PD activity can be monitored during service using the ultra-high frequency (UHF) method. In this contribution, a calibration procedure is proposed for the UHF method. The calibration process is req
APA, Harvard, Vancouver, ISO, and other styles
4

Siegel, Martin, Christoph Kattmann, Chandra Prakash Beura, Michael Beltle, and Stefan Tenbohlen. "Partial Discharge Monitoring of Power Transformers by Calibrated UHF Measurements." Journal of Energy - Energija 72, no. 4 (2024): 19–27. http://dx.doi.org/10.37798/2023724514.

Full text
Abstract:
Partial discharge (PD) measurement is an established technique to detect local defects in the oil/paper insulation. They can be measured by electrical PD measurements according to IEC 60270 or by electromagnetic measurements in the ultra-high frequency range (UHF: 300 MHz – 3 GHz). The electromagnetic emissions of PD are recorded using an UHF sensor which is inserted into the transformer tank. The importance of PD measurements is reflected in the standard for charge-based electrical measurements (IEC 60270). Because of the standard, apparent charge, QIEC, became an essential factor for determi
APA, Harvard, Vancouver, ISO, and other styles
5

Zheng, Xiang, and Jianwei Wang. "Design of a partial discharge calibrator." Journal of Physics: Conference Series 2803, no. 1 (2024): 012029. http://dx.doi.org/10.1088/1742-6596/2803/1/012029.

Full text
Abstract:
Abstract A partial discharge calibrator is an instrument used to calibrate partial discharge detection equipment. Partial discharge refers to the phenomenon of partial discharge in insulating materials, which is one of the important indicators of aging and damage to insulating materials. A partial discharge calibrator can be used to detect and calibrate the sensitivity and accuracy of partial discharge detection equipment to ensure that it can accurately detect and monitor the partial discharge phenomenon in insulation materials, so as to timely detect and prevent the aging and damage of insul
APA, Harvard, Vancouver, ISO, and other styles
6

Krbal, Michal, Ludek Pelikan, Jaroslav Stepanek, Jaroslava Orsagova, and Iraida Kolcunova. "A Physical Calibrator for Partial Discharge Meters." Energies 12, no. 11 (2019): 2057. http://dx.doi.org/10.3390/en12112057.

Full text
Abstract:
This article offers an alternative method of calibrating partial discharge meters for research and teaching purposes. Most current modern calibrators are implemented as precise voltage pulse sources with a coupling capacitor. However, our calibrator is based on the physical principles of dielectric materials distributed in a plane or space. Calibrator design is unique and there is an attempt to get closer to the behavior of the measured real objects. The calibration impulses are created by energy from a high voltage power supply at the specific or nominal value of the applied voltage. At the s
APA, Harvard, Vancouver, ISO, and other styles
7

Hu, Yun, Xing Zhang, Wei Dong Zhang, Qing Sen Sun, Ling Yu Cao, and Yue Hu. "Application of a Programmable Partial Discharge Calibrator." Applied Mechanics and Materials 526 (February 2014): 288–91. http://dx.doi.org/10.4028/www.scientific.net/amm.526.288.

Full text
Abstract:
This paper presents the application of a programmable partial discharge calibrator, which used to test the performance of four partial discharge measuring systems by injecting a program controlled known charge sequence into the device under test. Performance of linearity, response to opposite polarity pulses, pulse resolution time and response to random pulse sequence are compared and the results obtained show that the tests prescribed by the standards do not fully characterize the partial discharge measuring system behavior. A random partial discharge pulse sequence generated by this calibrat
APA, Harvard, Vancouver, ISO, and other styles
8

Pecorelli, M. A. "Miniature partial discharge calibrator synchronized by capacitive coupling." IEEE Transactions on Electrical Insulation 27, no. 1 (1992): 181–83. http://dx.doi.org/10.1109/14.123454.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Chiampi, M., G. Crotti, Yue Hu, and A. Sardi. "Development and Application of a Programmable Partial Discharge Calibrator." IEEE Transactions on Instrumentation and Measurement 58, no. 4 (2009): 768–74. http://dx.doi.org/10.1109/tim.2008.2007056.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Hamoodi, Ali N., Safwan A. Hamoodi, and Rasha A. Mohammed. "Partial discharge calibrator of a cavity inside high-voltage insulator." Open Engineering 12, no. 1 (2022): 468–76. http://dx.doi.org/10.1515/eng-2022-0048.

Full text
Abstract:
Abstract This article displayed the method of partial discharge (PD) measurement in high-voltage insulator and calibrating the effective element (capacitor) to enhance the PD signal. The cavity shapes were plate–plate, cylindrical and spherical inside the solid insulator. The proposed system enables from detecting the reverse and main discharge, respectively, through the rise and tail time of the pulses. PD that took place was bounded with internal cavities. Proteus simulator and Matlab simulation models were used to measure and display the PD signal. The results showed PD-calibrated waveforms
APA, Harvard, Vancouver, ISO, and other styles
More sources

Conference papers on the topic "Reference partial discharge calibrator"

1

Prochazka, Radek, and Jan Hlavacek. "Comparative Analysis of Methods for Partial Discharge Calibrator Performance." In 2024 IEEE International Conference on High Voltage Engineering and Applications (ICHVE). IEEE, 2024. http://dx.doi.org/10.1109/ichve61955.2024.10676179.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Liu Na, Li Zhi, and Qian Zheng. "Study on the calibration of partial discharge calibrator." In 2008 Conference on Precision Electromagnetic Measurements (CPEM 2008). IEEE, 2008. http://dx.doi.org/10.1109/cpem.2008.4574738.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Wu, Daokai, Xiaojun Wang, and Chuxuan Huang. "Design of wireless partial discharge digital calibrator based on LoRa." In 2022 41st Chinese Control Conference (CCC). IEEE, 2022. http://dx.doi.org/10.23919/ccc55666.2022.9901805.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Merev, A., I. Karaman, S. Dedeoglu, and Mehedin Arifovic. "Performance of Reference Partial Discharge Measurement System." In 2018 Conference on Precision Electromagnetic Measurements (CPEM 2018). IEEE, 2018. http://dx.doi.org/10.1109/cpem.2018.8500956.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Khayam, Umar, and Naufal Hilmi Fauzan. "Testing New Design Partial Discharge Detector Using Vector Network Analyzer and Charge Calibrator." In 2021 3rd International Conference on High Voltage Engineering and Power Systems (ICHVEPS). IEEE, 2021. http://dx.doi.org/10.1109/ichveps53178.2021.9601029.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Garnacho, F., A. Ramirez, F. Alvarez, A. Khamlichi, and J. Rovira. "Test Cells to Generate Reference Partial Discharge Series." In 2018 Conference on Precision Electromagnetic Measurements (CPEM 2018). IEEE, 2018. http://dx.doi.org/10.1109/cpem.2018.8500858.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Liu Na, Qian Zheng, Chen Jiawei, and Yin Mei. "Study on the capacitors of reference partial discharge calibritor." In 2010 Conference on Precision Electromagnetic Measurements (CPEM 2010). IEEE, 2010. http://dx.doi.org/10.1109/cpem.2010.5544153.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Garnacho Vecino, Fernando, Angel Ramirez Linares, Fernando Alvarez Gomez, Eduardo Arcones del Alamo, and Carlos Alberto Vera Romero. "Characterization of Partial Discharge Measuring Instruments by the Generation of Reference Insulation Defects in an Experimental Setup." In 2018 IEEE 2nd International Conference on Dielectrics (ICD). IEEE, 2018. http://dx.doi.org/10.1109/icd.2018.8468513.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Garnacho Vecino, Fernando, Angel Ramirez Linares, Fernando Alvarez Gomez, Eduardo Arcones del Alamo, and Carlos Alberto Vera Romero. "Characterization of Partial Discharge Measuring Instruments by the Generation of Reference Insulation Defects in an Experimental Setup." In 2018 IEEE 2nd International Conference on Dielectrics (ICD). IEEE, 2018. http://dx.doi.org/10.1109/icd.2018.8514779.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Rajić, Tomislav, Koviljka Stanković, and Đorđe Čubrić. "ISPITIVANJE INDUKTIVNIH NAPONSKIH MERNIH TRANSFORMATORAOTPORNOST IZOLACIJE I PARCIJALNA PRAŽNJENJA." In 36. Savetovanja CIGRE Srbija 2023 Fleksibilnost elektroenergetskog sistema. Srpski nacionalni komitet Međunarodnog saveta za velike električne mreže CIGRE Srbija, 2023. http://dx.doi.org/10.46793/cigre36.2053r.

Full text
Abstract:
During the monitoring, management and protection of electrical plants, networks and devices, regular measurement of various quantities is necessary. First of all, current and voltage measurements are basic. In this paper, attention is directed to voltage inductive transformers. The insulation is made of oil and it is necessary to regularly check the condition of the insulation in order to determine the need for its replacement. Of the many measurements that are made in practice, this paper will talk about insulation resistance and partial discharges in oil. Moisture and impurities mostly affec
APA, Harvard, Vancouver, ISO, and other styles

Reports on the topic "Reference partial discharge calibrator"

1

Hamill, Daniel, and Gabrielle David. Hydrologic analysis of field delineated ordinary high water marks for rivers and streams. Engineer Research and Development Center (U.S.), 2021. http://dx.doi.org/10.21079/11681/41681.

Full text
Abstract:
Streamflow influences the distribution and organization of high water marks along rivers and streams in a landscape. The federal definition of ordinary high water mark (OHWM) is defined by physical and vegetative field indicators that are used to identify inundation extents of ordinary high water levels without any reference to the relationship between streamflow and regulatory definition. Streamflow is the amount, or volume, of water that moves through a stream per unit time. This study explores regional characteristics and relationships between field-delineated OHWMs and frequency-magnitude
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!