Academic literature on the topic 'Réseaux de distribution HTA'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Réseaux de distribution HTA.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Réseaux de distribution HTA"

1

-MOLES, M. "Détecteurs de défaut directionnels pour réseaux HTA compensés." Revue de l'Electricité et de l'Electronique -, no. 02 (2000): 71. http://dx.doi.org/10.3845/ree.2000.016.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Pasternack, Iris, Heidi Anttila, Marjukka Mäkelä, Tuija Ikonen, Pirjo Räsänen, Kristian Lampe, Hans van Brabandt, et al. "Testing the HTA Core Model: Experiences from two pilot projects." International Journal of Technology Assessment in Health Care 25, S2 (December 2009): 21–27. http://dx.doi.org/10.1017/s026646230999064x.

Full text
Abstract:
Objectives: The aim of this study was to analyze and describe process and outcomes of two pilot assessments based on the HTA Core Model, discuss the applicability of the model, and explore areas of development.Methods: Data were gathered from HTA Core Model and pilot Core HTA documents, their validation feedback, questionnaires to investigators, meeting minutes, emails, and discussions in the coordinating team meetings in the Finnish Office for Health Technology Assessment (FINOHTA).Results: The elementary structure of the HTA Core Model proved useful in preparing HTAs. Clear scoping and good coordination in timing and distribution of work would probably help improve applicability and avoid duplication of work.Conclusions: The HTA Core Model can be developed into a platform that enables and encourages true HTA collaboration in terms of distribution of work and maximum utilization of a common pool of structured HTA information for national HTA reports.
APA, Harvard, Vancouver, ISO, and other styles
3

Zechmeister, Ingrid, and Ines Schumacher. "THE IMPACT OF HEALTH TECHNOLOGY ASSESSMENT REPORTS ON DECISION MAKING IN AUSTRIA." International Journal of Technology Assessment in Health Care 28, no. 1 (January 2012): 77–84. http://dx.doi.org/10.1017/s0266462311000729.

Full text
Abstract:
Objectives: Health technology assessment (HTA) was established in Austria in the 1990s and, since then, it has gained considerable importance. In this study, we aim to analyze whether the HTA reports that have been produced at the Institute for Technology Assessment (ITA) and at the Ludwig Boltzmann Institute for HTA (LBI-HTA) have had an impact on decision making within the Austrian health care system.Methods: We selected all reports that were intended for supporting (i) reimbursement/investment or (ii) disinvestment decisions. Eleven full HTA reports and fifty-eight rapid assessments fulfilled the inclusion criteria. We used interview data and administrative data on volumes, tariffs and expenditure of products/services to analyze whether and how reports were in reality used in decision making and what the consequences for health care expenditure and resource distribution have been.Results: Five full HTA reports and fifty-six rapid technology assessments were used for reimbursement decisions. Four full HTA reports and two rapid assessments were used for disinvestment decisions and resulted in reduced volumes and expenditure. Two full HTA reports showed no impact on decision making. Impact was most evident for hospital technologies.Conclusions: HTA has played some role in reducing volumes of over-supplied hospital technologies, resulting in reduced expenditure for several hospital providers. Additionally, it has been increasingly included in prospective planning and reimbursement decisions of late, indicating re-distribution of resources toward evidence-based technologies. However, further factors may have influenced the decisions, and the impact could be considerably increased by systematically incorporating HTA into the decision-making process in Austria.
APA, Harvard, Vancouver, ISO, and other styles
4

Pasternack, Iris, Ingrid de Groot, Sarah Kleijnen, and Paula Polman. "COMPARING THE HTA CORE MODEL WITH A NATIONAL HEALTH TECHNOLOGY ASSESSMENT REPORT." International Journal of Technology Assessment in Health Care 30, no. 5 (November 2014): 530–35. http://dx.doi.org/10.1017/s0266462314000610.

Full text
Abstract:
Objectives: The HTA Core Model is a framework for producing health technology assessments (HTAs) in a structured format. The Model splits the content of a HTA into assessment elements. The objective is to explore the adaptability of these assessment elements in national report production in a pilot case study comparing a national HTA report and the HTA Core Model.Methods: An on-going Dutch HTA report on endovascular repair of abdominal aortic aneurysm (EVAR) was chosen as a typical representative of a national report on medical interventions. The author of the EVAR report assessed the relevance and comprehensiveness of the assessment elements of the HTA Core Model for her work. Another researcher annotated the Core Model specific content in the EVAR report. Matching and missing content, as well as the distribution of information in the EVAR report were tabulated and analysed in joint deliberations.Results: Forty percent of the assessment elements of the Core Model were considered relevant for the EVAR report. Some issues relevant for EVAR but missing from the Core Model were identified: they were about re-interventions, secondary prevention, subpopulations that benefit most, and the length of the hospital stay. The distribution of information differed substantially between the Code Model and the national report.Conclusions: The assessment elements of the HTA Core Model covered most relevant questions of the national report. In order to facilitate easy adaptation of information, the distribution of information should be more consistent in the national report and the Core model.
APA, Harvard, Vancouver, ISO, and other styles
5

Venard, Bertrand. "Analyse du fonctionnement des réseaux de distribution." La Revue des Sciences de Gestion, Direction et Gestion, no. 154 (August 1995): 21–29. http://dx.doi.org/10.1051/larsg:1995044.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Sibille, Isabelle. "Stabilité biologique des réseaux de distribution d'eau potable." L’Année Biologique 37, no. 3 (July 1998): 117–61. http://dx.doi.org/10.1016/s0003-5017(98)80014-7.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

-SORREL, Jean-Paul. "Architecture, conception et protection des réseaux de distribution." Revue de l'Electricité et de l'Electronique -, no. 09 (2000): 62. http://dx.doi.org/10.3845/ree.2000.092.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Ahmad-Kassem, Ahmad, and Stéphane Grumbach. "Distribution d’applications client-serveur sur des réseaux déclaratifs." Ingénierie des systèmes d'information 17, no. 5 (October 28, 2012): 113–38. http://dx.doi.org/10.3166/isi.17.5.113-138.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Verbeek, Joost, Mickaël Hiligsmann, Americo Cicchetti, and Marco Marchetti. "SHARING AND COLLECTING HOSPITAL-BASED HEALTH TECHNOLOGY ASSESSMENT REPORTS INTERNATIONALLY: IS AN EXTENSIVE PARTICIPATION OF STAKEHOLDERS REALISTIC?" International Journal of Technology Assessment in Health Care 34, no. 5 (2018): 527–34. http://dx.doi.org/10.1017/s0266462318000570.

Full text
Abstract:
Objectives:The emergence of new medical technologies and budget restrictions has led to a substantial increase in the use of hospital-based health technology assessment (HB-HTA). This qualitative study explores whether there is a possibility and interest to realize the collection and dissemination of HB-HTA reports on an international scale by exploring the opinions from HB-HTA experts.Methods:A survey was designed and sent to an international group of experts knowledgeable in HB-HTA from eighteen different countries. The survey contained questions about their opinions on the collection and distribution of HB-HTA information, and about the meaningful dimensions, barriers and values about a database. The data obtained were analyzed through the method of content analysis.Results:A total of thirty-six experts (response rate of 18.3 percent) responded to the survey. The obtained data shows that all respondents agree that the collection of HB-HTA reports is useful. Moreover, 41.7 percent of respondents that are in the position of sharing HB-HTA reports (n= 24) mentioned that full HB-HTA reports can be shared. Many other respondents reported that confidentiality (45.7 percent) and investment into a database (40.0 percent) are important barriers for the dissemination of HB-HTA reports.Conclusions:There seem to be enough demand and willingness to share all or most reports by a large community of HB-HTA producers. Therefore, there is a need for a well-designed database with regular maintenance and complete, comparable, and qualitative HB-HTA reports. The database of the AdHopHTA project could potentially facilitate this process.
APA, Harvard, Vancouver, ISO, and other styles
10

Ledrappier, François. "Distribution des orbites des réseaux sur le plan réel." Comptes Rendus de l'Académie des Sciences - Series I - Mathematics 329, no. 1 (July 1999): 61–64. http://dx.doi.org/10.1016/s0764-4442(99)80462-5.

Full text
APA, Harvard, Vancouver, ISO, and other styles
More sources

Dissertations / Theses on the topic "Réseaux de distribution HTA"

1

Pham, Cong Duc. "Détection et localisation de défauts dans les réseaux de distribution HTA en présence de génération d'énergie dispersée." Grenoble INPG, 2005. https://tel.archives-ouvertes.fr/tel-00164643.

Full text
Abstract:
Ce travail de thèse a portè sur la détection et localisation de défauts dans les rèseaux de distribution HT A par les indicateurs de passage de défaut (IPD). Les études ont été effectuées dans le cadre du développement attendu et croissant des GED (sources de Génération d'Energie Décentralisées). La première partie du mémoire est consacrée à l'analyse du comportement des IPD. En ce qui concerne l'influence du contexte de fonctionnement sur la réponse des IPD, une partie est destinée à vérifier le fonctionnement des modèles IPD développés et les règles d'utilisation des IPD prévus. Une autre analyse l'influence des GED sur l'utilisation des IPD sur la détection et localisation de défauts. Pour l'amélioration de la robustesse du diagnostic avec IPD en présence de fausses indications, une méthode de détermination de la section en défaut (limitée par des IPD) est proposée. La deuxième partie du mémoire est consacrée à une méthode d'optimisation du placement des IPD dans les réseaux HTA sur la base d'algorithmes génétiques. Nous avons défini différents critères pour l'optimisation; ils sont validés par un programme de calcul des indices de fiabilité. L'influence de la GED dans le départ HTA sur le placement optimal des IPD est analysée en tenant compte du coût dl l'énergie non fournie par la GED et du fonctionnement envisageable comme un secours de la GED
This thesis concerned the fault detection and location in the distribution networks by the fault indicators (FI). The studies were carried out within the framework of the development of dispersed generation (DG) sources. The first part of the thesis consists in analyzing the FI behavior. With regard to the influence of the context of network operation on the FI response, a part is intended to verity the operation of FI models developed and the rules of FI use envisaged. Another part analyses the DG influence on the fault detection and location by FI. For improvement of the robustness of the diagnosis with FI in the case of false responses, a method of fault section determination (Iimited by FI) is proposed. The second part of the thesis presents a method of optimization of the FI placement in distribution networks. We defined various criteria for optimization; they are validated by a reliability calculation program. Taking into account the constraints on the objective function, the genetic algorithm was selected for optimization. The DG influence on the optimal FI placement is analyzed by taking account of the cost a the not provided DG energy and possible DG back-up operation
APA, Harvard, Vancouver, ISO, and other styles
2

Welfonder, Till. "Localisation de défauts monophasés dans les réseaux de distribution à neutre compensé." Phd thesis, Grenoble INPG, 1998. http://tel.archives-ouvertes.fr/tel-00824852.

Full text
Abstract:
La mise à la terre du point neutre des réseaux de distribution par une bobine de compensation réduit le courant de défaut lors d'un défaut monophasé, ce qui est le type de défaut le plus souvent rencontré dans l'exploitation. Cette mesure améliore la qualité de service, mats rend la détection et la localisation de défauts plus difficiles. Cette thèse traite de la localisation de défauts à faible résistance, auto-extincteurs ou permanents dans les réseaux compensés arborescents. Les phénomènes transitoires lors d'un défaut sont étudiés et une nouvelle approche pour la localisation est développée. L'approche est basée sur l'exploitation des signaux au niveau du poste de transformation HT/MT à une fréquence de résonance caractéristique. Un algorithme de localisation de défaut a été conçu, réalisé et testé. Son fonctionnement est validé avec des simulations de réseau et avec des enregistrements de défauts réels. L'influence des différents paramètres sur la précision de l'algorithme est examinée et expliquée.
APA, Harvard, Vancouver, ISO, and other styles
3

He, Yujun. "Contribution au réglage de la tension sur un réseau HTA avec producteurs. Apport de la flexibilité de la demande." Thesis, CentraleSupélec, 2015. http://www.theses.fr/2015SUPL0005/document.

Full text
Abstract:
L’intégration des producteurs décentralisés (DG) dans un réseau de distribution peut modifier le profil de tension et influencer le réglage de tension conventionnel. Pour le bon fonctionnement du réseau, le raccordement des DG ainsi que les charges grosses sont limités par le dimensionnement du réseau. Les travaux de cette thèse ont pour but de proposer une approche du réglage de tension dans un réseau de distribution avec producteur, en appuyant sur la flexibilité de la demande. Les moyens de réglage de tension seront constitués du régleur en charge (OLTC), la régulation de DG ainsi que la demande flexible. Une optimisation centralisée de type MINLP est proposée pour coordonner ces moyens de réglage. Il est montré que si les moyens de l’OLTC et de la puissance réactive ne suffissent pas de lever la contrainte de tension, il faut réduire la puissance active de producteur. Pour le gain de producteur, la demande flexible peut être considérée comme une source active. La modulation de « demand response » (DR) utilisant les charges thermiques est alors proposée au réglage de tension. L’effet de rebond est pris en compte pour les charges thermiques afin de ne pas affecter le profil de tension après l’action de DR. Ces travaux permettent d’envisager un réglage de tension plus active dans le réseau intelligent et augmenter la flexibilité du réseau
Growth of distributed generations (DG) in actual distribution networks will bring voltage issues that cannot be fixed by conventional voltage control means. For the sake of network safety, the size of DG and load in a distribution network is limited by the network parameters. The research described in this thesis aims to propose a voltage control strategy on distribution networks using the flexibility of demand. The voltage control means will consist of the on load tap changer (OLTC), the regulation of DG, and flexible demand. A centralized optimization of MINLP type is proposed to coordinate these voltage control means. It shows if it is not able to remove the voltage constraint with OLTC and reactive power regulation, then it must reduce the active power of DG. In order not to reduce active power of DG, the flexible demand is considered as an active source to take part in voltage control. The demand response (DR) modulation using thermal loads is thus proposed for voltage control. For the thermal load, the cold load pick-up (CLPU) effect must be taken into account in order not to affect the voltage profile after DR action. This work allows us to consider a voltage control strategy more active in smart distribution network and improve the flexibility of network
APA, Harvard, Vancouver, ISO, and other styles
4

Lefort, Romain. "Contribution des technologies CPL et sans fil à la supervision des réseaux de distribution d'électricité." Thesis, Poitiers, 2015. http://www.theses.fr/2015POIT2253/document.

Full text
Abstract:
Le déploiement d'une infrastructure de supervision permet une gestion plus intelligente des réseaux de distribution d'électricité comparé à un renforcement traditionnel pour répondre aux nouveaux enjeux de la maitrise de l'énergie (Consommations, EnR, VE, ...). Pour acheminer les données, les Courants Porteurs en Ligne (CPL) possèdent un atout majeur. En effet, cette technologie permet de superposer un signal de plus haute fréquence au signal électrique 50/60 Hz. Toutefois, le support de transmission est difficile et non maîtrisable. Ces travaux de recherche ont pour objectif d'apporter une contribution à cette problématique par l'élaboration d'une plateforme de simulation des réseaux pour des fréquences allant jusqu'à 1 MHz dans un but de transmission de données. Des éléments clés des réseaux sont traités de façon séparés puis assemblés pour estimer les performances des CPL « Outdoor » actuels. La variation du comportement des réseaux en fonction du temps et de la fréquence, en particulier des perturbations en tête d'installation clients sur 24h est étudiée. Les transformateurs entre les réseaux HTA et BT sont modélisés sous la forme d'un « modèle à constantes localisées » et d'un « modèle boite noire ». Les deux modèles sont appliqués sur un transformateur H61 100 kVA. Par la suite, une modélisation des câbles de distribution est proposée sous forme d'un « modèle cascadé ». Celle-ci est appliquée sur un câble souterrain BT. Chaque modèle est obtenu à l'aide de mesures d'impédances, et validé par des mesures de transmissions. Pour compléter, une étude préliminaire sur les communications radio mobile est réalisée pour la supervision des réseaux de distribution
Establishing a supervisory infrastructure allows a better smart management than an expensive strengthening of distribution network to respond to new constraints at the energies control (Consumption, REN, EV ...). To transmit data, Power Line Communication (PLC) technologies present an advantage in this context. In fact, it enables a superposition of High Frequency (HF) signals on electrical signal 50/60 Hz. However, electric networks have not been developed to this application because of difficult propagation conditions. This research work makes a contribution to develop a simulation platform in objective to transmit data to 1 MHz. In first time, each network element is studied singly and in second time, together, to estimate "Outdoor PLC" transmission performance. The first element studied is the networks variation in function of frequency and time. Several 24h disturbance measurements on LV customers are presented. The second element is the transformers which established connection between Medium Voltage (MV) and Low Voltage (LV). The proposed modeling method is based on a "lumped model" and a "black box model". These models are applied to a 100 kVA H61 transformer most commonly used by French distribution system operator in rural and suburban networks. The third element is the power line used in MV and LV networks. The proposed modeling method is based on a "cascaded model" from the theory of transmission line. This model is applied to one power line used in LV underground network. Each model is obtained from various impedance measurements. To complete, an introductory study on mobile radio communication is performed to remote network distribution
APA, Harvard, Vancouver, ISO, and other styles
5

Le, Trung Dung. "Contribution des moyens de production dispersés aux courants de défaut. Modélisation des moyens de production et algorithmes de détection de défaut." Thesis, Supélec, 2014. http://www.theses.fr/2014SUPL0009/document.

Full text
Abstract:
Les travaux de la thèse se focalisent sur la protection des réseaux de distribution HTA en présence des générateurs distribués (éoliennes, fermes solaires,...). Dans un premier temps, un état de l’art a été réalisé sur les comportements des générateurs en creux de tension, leurs impacts sur le système de protection et les pistes de solution proposées pour y remédier. L’étape suivante est la mise au point d’algorithmes directionnels de détection de défauts, sans mesure de tension. Ces algorithmes s’appuient sur la décomposition en composantes symétriques des courants mesurés. Ces relais doivent empêcher le déclenchement intempestif de protections de surintensité dû au courant de défaut provenant des générateurs distribués. Ils sont moins coûteux par rapport à ceux traditionnels car les capteurs de tension, qui sont indispensables pour ces derniers, peuvent être enlevés. Après détection d’un défaut sur critère de seuil simple (max de I ou max de I résiduel), la direction est évaluée à l’aide d’un algorithme en delta basé sur les rapports courants inverse-homopolaire ou inverse-direct, selon le type de défaut (monophasé ou biphasé). En se basant sur ces rapports, un classifieur SVM (Support Vector Machines), entrainé préalablement à partir des simulations, donne ensuite l’estimation de la direction du défaut (amont ou aval par rapport au relais). La bonne performance de ces algorithmes a été montrée dans la thèse pour différents paramètres du réseau et en présence de différents types de générateurs. Le développement de tels algorithmes favorise la mise en œuvre des protections en réseau, qui pourraient être installées dans les futurs Smart Grids
This research focuses on the protection of MV distribution networks with Distributed Generators (DGs), such as wind farms or photovoltaic farms, etc. First, the state of art is carried out on fault behaviour of DGs, their impacts on protection system and the mitigation solutions. Next, algorithms are developed for directional relays without voltage sensors. Based on the symmetrical component method, these algorithms help the overcurrent protections to avoid the false tripping issue due to fault contribution of DGs. With the suppression of voltage sensors, such directional relays become cheaper in comparison with the traditional ones. Following the fault detection (the phase or residual current reaches the pick-up value) and depending on fault type (line-to-ground or line-to-line fault), the ratios between the variation (before and during fault) of negative-zero sequence or negative-positive sequence currents are calculated. From these ratios, a SVM (Support Vector Machines) classifier estimates the fault direction (upstream or downstream the detector). The classifier is trained beforehand from transient simulations. This survey shows good performances of the directional algorithms with different network parameters and different kinds of DGs. Such algorithms could be implemented in protections along the feeders in the future smart grids
APA, Harvard, Vancouver, ISO, and other styles
6

Caujolle, Mathieu. "Identification et caractérisation des perturbations affectant les réseaux électriques HTA." Phd thesis, Supélec, 2011. http://tel.archives-ouvertes.fr/tel-00650911.

Full text
Abstract:
La reconnaissance des perturbations survenant sur les réseaux HTA est une problématique essentielle pour les clients industriels comme pour le gestionnaire du réseau. Ces travaux de thèse ont permis de développer un système d'identification automatique. Il s'appuie sur des méthodes de segmentation qui décomposent de manière précise et efficace les régimes transitoires et permanents des perturbations. Elles utilisent des filtres de types Kalman linéaire ou anti-harmoniques pour extraire les régimes transitoires. La prise en compte des variations harmoniques et de la présence de transitoires proches se fait à l'aide de seuils adaptatifs. Des méthodes de correction du retard a posteriori permettent d'améliorer la précision de la décomposition. Des indicateurs adaptés à la dynamique des régimes de fonctionnement analysés sont utilisés pour caractériser les perturbations. Peu sensibles aux erreurs de segmentation et aux perturbations harmoniques, ils permettent une description fiable des phases des perturbations. Deux types de systèmes de décision ont également été étudiés : des systèmes experts et des classifieurs SVM. Ces systèmes ont été mis au point à partir d'une large base de perturbations simulées. Leurs performances ont été évaluées sur une base de perturbations réelles : ils déterminent efficacement le type et la direction des perturbations observées (taux de reconnaissance moyen > 98%).
APA, Harvard, Vancouver, ISO, and other styles
7

LAZAR-MOCANU, LAZAR INES, and J. M. ESCANE. "Simplification d'un modele de reseau de distribution hta avec la methode d'agregation." Paris 6, 1995. http://www.theses.fr/1995PA066134.

Full text
Abstract:
Les reseaux de distribution (hta), aeriens et souterrains, ruraux et urbains, ont une structure radiale assez simple mais sont constitues d'un nombre important d'elements differents qui rendent difficiles leur modelisation. L'objectif de cette these est de presenter une methode systematique qui permet d'obtenir un modele simple de reseau de distribution en regime transitoire. Ce modele doit etre caracterise par un nombre reduit de parametres correles avec la nature physique des elements du reseau. La methode de simplification choisie est l'agregation. Elle a l'avantage d'offrir un modele reduit qui donne une bonne approximation du fonctionnement du systeme initial en regime transitoire et permanent et elle offre une relation entre le systeme initial et le modele simplifie. Afin de ne pas perdre les liaisons physiques entre le modele determine et le reseau initial de distribution, tres complexe, le probleme est decompose. Pour chaque depart arborescent, un modele simple, determine avec la methode d'agregation est propose. Ensuite, l'agregation est appliquee au reseau de distribution, mis sous forme radiale, et le modele agrege representatif en regime transitoire est determine. Les parametres de ce modele peuvent etre correles aux donnees globales de chaque depart et un modele physique representatif est alors obtenu. Les validations avec des enregistrements dans le reseau de distribution montre que les resultats sont concluants
APA, Harvard, Vancouver, ISO, and other styles
8

ʿAllūš, I. S. "Classification et caracterisation des defauts monophases sur les reseaux de distribution hta." Paris 6, 1997. http://www.theses.fr/1997PA066600.

Full text
Abstract:
Cette these est consacree a la classification et la caracterisation des defauts monophases sur les reseaux hta. Bien identifier les defauts, pour mieux alimenter les clients, devrait permettre, a terme, d'optimiser la maintenance des reseaux et d'augmenter la duree de vie des ouvrages. Actuellement, dans les postes htb/hta qui sont instrumentes, l'acquisition des signaux se fait au mieux avec une frequence d'echantillonnage de 10 khz. Elle est plus couramment egale a 3 khz, ce qui semble insuffisant pour la reconnaissance des defauts. De plus, pour la plupart des signaux qui sont disponibles, on ne dispose pas de d'information quant a la nature physique du defaut. Afin d'obtenir les informations necessaires a l'etude envisagee, la direction des etudes et recherches d'electricite de france s'est dotee d'un reseau experimental hta situe au laboratoire de genie electrique des renardieres. Celui-ci a permis de provoquer et de reproduire plusieurs plus de 700 echantillons de defauts monophases en regime de neutre resistif et autant en regime de neutre compense. Quatre types de defauts ont ete consideres : les contacts directs sur bitume, sur terre et sur herbe, et les contournements d'isolateurs. Les trois premiers pour des raisons de securite (risques d'electrocution et d'incendie) et les quatriemes parcequ'ils constituent des signes precurseurs d'avaries plus importantes. Les experimentations ont ete faites en deux points differents du reseau experimental, afin de pouvoir etudier l'influence de la localisation du defaut. Differentes methodes de traitement du signal (prony, transformee de fourier, decomposition en ondelettes, distribution pseudo wigner ville lissee) ont ete utilisees afin de preparer les donnees a l'utilisation de deux methodes statistiques : l'analyse en composantes principales et l'analyse discriminante. Cette approche a permis de demontrer qu'il existait des possibilites de discrimination des defauts suivant leur origine physique, a basses frequences et a partir du poste htb/hta. Celles-ci semblent plus importantes pour les vecteurs descripteurs issus du courant residuel que pour ceux obtenus a partir de la tension de la phase en defaut. Elles ouvrent de nouvelles perspectives quant a la surveillance et la maintenance des reseaux de distribution hta. Precurseurs d'avaries plus importantes. Les experimentations ont ete faites en deux points differents du reseau experimental, afin de pouvoir etudier l'influence de la localisation du defaut. Differentes methodes de traitement du signal (prony, transformee de fourier, decomposition en ondelettes, distribution pseudo wigner ville lissee ) ont ete utilisees afin de preparer les donnees a l'utilisation de deux methodes statistiques : l'analyse en composantes principales et l'analyse discriminante. Cette approche a permis de demontrer qu'il existait des possibilites de discrimination des defauts suivant leur origine physique, a basses frequences et a partir du poste htb/hta. Celles-ci semblent plus importantes pour les vecteurs descripteurs issus du courant residuel que pour ceux obtenus a partir de la tension de la phase en defaut. Elles ouvrent de nouvelles perspectives quant a la surveillance et la maintenance des reseaux de distribution hta.
APA, Harvard, Vancouver, ISO, and other styles
9

VALENTI, ARNAUD. "Localisation de defauts monophases a la terre dans les reseaux de distribution hta." Paris 6, 2000. http://www.theses.fr/2000PA066465.

Full text
Abstract:
Dans le but de reduire le nombre de coupures sur les reseaux hta et d'ameliorer la qualite de la fourniture, la division r&d de edf a engage des actions sur la localisation a distance des defauts monophases a la terre. La technique de localisation envisagee ici est fondee sur l'analyse des phenomenes de propagation et de reflexion des ondes dans ces reseaux electriques arborescents. Elle est independante du regime de neutre et peut etre etendue a n'importe quel type de defaut. L'apparition d'un defaut genere un echelon (tension + courant) qui va se propager au sein du reseau et se reflechir a chaque rupture d'impedance et notamment au lieu du defaut pour finalement engendrer des ondes stationnaires. Le courant et la tension contiennent ainsi l'un et l'autre au moins une frequence caracteristique de la position du defaut. La relation etablie entre cette frequence et le lieu du defaut resulte d'une etude approfondie de l'equation differentielle dites des telegraphistes, appliquee a un systeme de lignes triphasees. Malheureusement, l'algorithme developpe ici pour fournir la position du defaut au sein du reseau necessite actuellement la connaissance au prealable du troncon en defaut ainsi que la connaissance des impedances a chaque extremite du reseau. De plus, ses performances en simulation sur des topologies de reseau hta reels ne sont pas tres bonnes a cause justement de l'arborescence de ce type de reseau. Cette technique de localisation de defaut haute frequence devient cependant opportune dans le cas de reseaux dont l'arborescence reste simple. Ce resultat est valide par des campagnes de mesures experimentales. Finalement, une methode de localisation de defaut basee sur les phenomenes de propagation et reflexion des ondes parait difficilement utilisable dans le cas de reseaux hta arborescents, mais elle peut s'averer pertinente pour localiser un defaut dans un reseau htb ou dans un cable souterrain meme s'il y a une derivation.
APA, Harvard, Vancouver, ISO, and other styles
10

Amiel-Cosme, Laurence. "Les réseaux de distribution." Paris 1, 1994. http://www.theses.fr/1994PA010296.

Full text
Abstract:
Le réseau de distribution est celui qui nait de la somme de volontés individuelles, unissant un fournisseur, l'intégrateur, à une pluralité de revendeurs, distributeurs intégrés, donnant naissance à des accords-cadres principaux liés à des contrats accessoires, constituant un groupe de contrats synallagmatiques, conclus à titre onéreux et dans l'intérêt commun de ses membres, en vue d'organiser la revente de produits et ou la fourniture de services, sur un marché détermine, à un consommateur final. Ainsi défini, le réseau de distribution répond aux critères constitutifs suivants : d'abord, pour exister, le réseau se fonde sur une pluralité de volontés individuelles unissant un fournisseur à une multitude de distributeurs, matérialisée par l'existence d'un groupe d'accords-cadres. Ensuite, la création du réseau conduit à une mise en commun d'apports. Les distributeurs mettent à la disposition du réseau les qualifications professionnelles attendues. Et les prestations de ceux qui acquièrent la qualité de distributeur intégré invitent alors à considérer que la multitude des liens d'intuitus personae se conçoivent comme mis à la disposition d'un intuitus firmace. Du côté de l'intégrateur, la mise à disposition d'une enseigne ou de matériels autorise la qualification d'un apport en jouissance au réseau. En outre, l'appartenance à ce réseau postule la présence d'un affectio cooperandi, traduisant une volonté intéressée de collaborer de bonne foi sur un pied d’égalité juridique au développement de l'œuvre commune. Enfin, il n'y a pas de contribution aux pertes et aux bénéfices du réseau. Chaque membre, juridiquement indépendant, agit à ses risques et périls. Le réseau de distribution répond ainsi à une réalité juridique et non plus seulement économiquement, sans qu'il soit nécessaire que le législateur reconnaisse la personnalité morale à ce groupement de personnes
The distribution network is an entiry organized with the sum of individual wills, joining together a supplier, the integrator, and several resellers, integrated distributors. This device gives birth to principal standard agreements linked to accessory contracts creating a group of synallagmatical contracts, concluded in the common interest of its members in order to organize the resale of products and or service supplies to a final consumer, on a determined market. Defined as above, the criteria to create a distributioin network are the following : first, to exist, the network must be based on a plurality of individual wills joining together a supplier to a multitude of distributors, which could be materialized in a group of standard agreements. Second, the creation of the network implies putting capital contributions in common. The distributors place at the network disposal their professional skills. Moreover, the rendering of services of the ones who acquire the title of integrated distributor may involves thatthe multiplicity of intuitus personae links be placed at the disposal of an intuitus firmae. As for the integrator, the placing at disposal of a commercial sign or equipment allows to adopt the qualification of network capital contribution. Besides, being a member of this network materializes the existence of an affectio cooperandi which reflects a real will to collaborate, in good faith and at the same legal level, to the development of the common goal. Finally, there is no responsability for losses and profits of the network. Each membre, as a legal independant entity, acts at his her own risks. The distribution network is the appropriate form to face the legal reality in addition to the economical one, without the necessity for the legislative power to recognize a legal entity to this association of persons
APA, Harvard, Vancouver, ISO, and other styles
More sources

Books on the topic "Réseaux de distribution HTA"

1

Commission des Communautés européennes. Direction générale audiovisuel, information, communication et culture. Les réseaux transeuropéens. Luxembourg: Office des publications officielles des Communautés européennes, 1994.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
2

l'environnement, Ontario Ministère de. Réseaux de distribution de l'eau et réseaux d'égouts de l'Ontario: Subventions directes. S.l: s.n, 1988.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
3

Canada, Énergie mines et ressources Canada. Réseaux de distribution d'eau et d'air comprimé. Ottawa, Ont: Énergie, mines et ressources Canada, 1985.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
4

Maul, A. Stratégies d'échantillonnage pour analyse microbiologique sur réseaux de distribution d'eau: Méthodes et programmes informatiques. Paris: Technique et documentation, 1989.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
5

France. Conseil économique et social. Le rôle des réseaux de distribution dans l'aménagement du territoire: Séances des 9 et 10 novembre 1993. Paris: Direction des journaux officiels, 1993.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
6

Association pour l'histoire de l'électricité en France. Colloque. Réseaux électriques et installateurs: Actes du 8e colloque de l'AHEF, 14-16 octobre 1992, Paris, Espace Electra. Paris: Association pour l'histoire de l'électricité en France, 1995.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
7

Tourneau, Philippe Le. Les contrats de franchisage: Franchisage de distribution, de comptoir, industriel, artisanal, financier, franchisage de service, franchisage international, réseaux de franchisage. Paris: Litec, 2003.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
8

d'essence, Groupe d'étude national sur la récupération des vapeurs dans les réseaux de distribution. Code de recommandations techniques pour la protection de l'environnement applicable à la récupération des vapeurs dans les réseaux de distribution d'essence. [Winnipeg]: Conseil canadien des ministres de l'environnement, 1991.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
9

Wildi, Théodore. Électrotechnique. 4th ed. Sainte-Foy, Qué: Presses de l'Université Laval, 2005.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
10

Mirucki, Jean. Le marché du livre au Canada: Les lecteurs, les composantes du marché et les réseaux de distribution du livre francophone au Canada : rapport d'étude. [Montréal]: Université du Québec à Montréal, Dép. des sciences économiques, 1986.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
More sources

Book chapters on the topic "Réseaux de distribution HTA"

1

Chaudey, Magali, and Muriel Fadairo. "Choix de localisation et réseaux de distribution." In Retailing et localisation, 205–17. Presses universitaires de Provence, 2018. http://dx.doi.org/10.4000/books.pup.31583.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Wiart, Louis. "Chapitre 2. La distribution des activités prescriptives." In La prescription littéraire en réseaux : enquête dans l’univers numérique, 256–86. Presses de l’enssib, 2017. http://dx.doi.org/10.4000/books.pressesenssib.7495.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Tran, Nicolas. "Les entrepôts dans le métier de négociant romain : associations professionnelles et réseaux commerciaux." In Entrepôts et circuits de distribution en Méditerranée antique, 123–36. École française d’Athènes, 2018. http://dx.doi.org/10.4000/books.efa.3470.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Srour, Némésis. "Chapitre 11. Réappropriation des réseaux de distribution de films indiens au Moyen-Orient : entre hégémonie hollywoodienne et concentrations émiraties." In La circulation des productions culturelles. Centre Jacques-Berque, 2017. http://dx.doi.org/10.4000/books.cjb.1234.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Conference papers on the topic "Réseaux de distribution HTA"

1

Lextrait, Hervé. "Impact sur les réseaux de distribution et solutions smart grid." In Sources de production centralisées et décentralisées : le fonctionnement du réseau électrique aujourd'hui et demain. Les Ulis, France: EDP Sciences, 2018. http://dx.doi.org/10.1051/jtsfen/2018sou04.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Mkattiri, Sara, and Abdallah Saad. "Islanding operation of an HTA network, Analysis of the impact of decentralized energy generation on the transient stability of an HTA distribution network." In 2018 Renewable Energies, Power Systems & Green Inclusive Economy (REPS-GIE). IEEE, 2018. http://dx.doi.org/10.1109/repsgie.2018.8488854.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Mkattiri, Sara, and Abdallah Saad. "Analysis of the impact of the integration of renewable energies on HTA distribution networks in Morocco." In 2018 19th IEEE Mediterranean Electrotechnical Conference (MELECON). IEEE, 2018. http://dx.doi.org/10.1109/melcon.2018.8379058.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Hosaka, Tomoyuki, Taisuke Sugii, Eiji Ishii, Kazuhiro Oryoji, and Yoshihiro Sukegawa. "Application of Hyperbolic Tangent Approximation Model to Gasoline Direct Injection Engine Simulation." In ASME 2017 Internal Combustion Engine Division Fall Technical Conference. American Society of Mechanical Engineers, 2017. http://dx.doi.org/10.1115/icef2017-3538.

Full text
Abstract:
The improved fuel economy and low pollutant emissions are highly demanded for internal combustion engines. Gasoline Direct Injection (GDI) engine is the one of promising devices for highly efficient engine. However, GDI engines generally tend to emit more Particulate Matter (PM) than Port Fuel Injection (PFI) engine because the fuel sprayed from the injector can easily attach to the wall, which is the major origin of PM. Therefore, the precise analysis of the fuel/air mixture formation and the prediction of emissions are required. From the view of industrial use, Computational Fluid Dynamics (CFD) becomes a necessary tool for the various analyses including the fuel/air mixture formation, spray attachment on the cylinder wall, the in-cylinder turbulence formation, the combustion and emission etc. In our previous study, the flow and spray simulation in internal combustion engine has been conducted using OpenFOAM®, the open-source CFD toolbox. Since the engine involves the dynamic motion such as valve and piston, the morphing and mapping approach was employed. Furthermore, by virtue of open-source code, we have developed the methodology of the hybrid simulation from the internal nozzle flow to the fuel/air mixture in order to take into account detailed breakup process nearby injector nozzle. We expand the above research to the combustion simulation. For the combustion model, the Hyperbolic Tangent Approximation (HTA) model is adopted. The HTA model has a simple form of equation and one can easily implement; moreover, the HTA model has the following features: 1. capability of both laminar and turbulent flow, 2. the clearness of analytical derivation based on the functional approximation of the reaction progress variable distribution in a one-dimensional laminar flame. In the current study, the premixed flame is studied on a gasoline combustion engine. The simulations for in-cylinder engine are conducted with different Air/Fuel (A/F) ratio conditions, and the results are compared with the experimental results. The in-cylinder pressure agrees well with experimental results and the validity of the current methodology is confirmed.
APA, Harvard, Vancouver, ISO, and other styles

Reports on the topic "Réseaux de distribution HTA"

1

Réseaux de distribution d'eau et d'air comprimé. Natural Resources Canada/ESS/Scientific and Technical Publishing Services, 1985. http://dx.doi.org/10.4095/313704.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Réseaux de distribution d'eau et d'air comprimé. Natural Resources Canada/ESS/Scientific and Technical Publishing Services, 1987. http://dx.doi.org/10.4095/313761.

Full text
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!