1

Czapp, Stanislaw, Krzysztof Dobrzynski, Jacek Klucznik, Zbigniew Lubosny, and Robert Kowalak. "Improving sensitivity of residual current transformers to high frequency earth fault currents." Archives of Electrical Engineering 66, no. 3 (2017): 485–94. http://dx.doi.org/10.1515/aee-2017-0036.

Full text
Abstract:
Abstract For protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when high frequency earth fault current occurs. Serious hazard of electrocution exists then. In order to detect such a current, it is necessary to modify parameters of residual current devices, especially the operating point of their current transformer. The authors proposed the modification in the structure of residual current devices. This modification improves sensitivity of residual current devices when high frequency earth faul
APA, Harvard, Vancouver, ISO, and other styles
2

João, S. S. Luna, and O. Cavalcanti Gustavo. "USE OF RESIDUAL CURRENT DEVICES AS LEAKAGE CURRENT DETECTORS OF SURGE PROTECTION DEVICES." Revistaft 28, no. 130 (2024): 96. https://doi.org/10.5281/zenodo.10520896.

Full text
Abstract:
Surge protection devices are equipment used to combat damage at electronic equipment caused by power surges produced by lightning discharges. Its main component, the varistor, acts as a variable resistor, depending on the voltage to which it is subjected. Leakage currents above 1ma at operating voltage indicate that the varistors have exceeded their acceptable current limits, and that their life expectancy is nearing the end. This article presents a solution for detecting leakage currents above acceptable limits in surge protection devices using residual current devices.
APA, Harvard, Vancouver, ISO, and other styles
3

Erwin, Sutanto, Chandra Frangky, Gonnelli Eduardo, and Suhariningsih. "Residual Current Measurement using Helmholtz Coil Configuration with different Current Flow." International Journal of Electrical and Computer Engineering (IJECE) 8, no. 3 (2018): 1432–41. https://doi.org/10.11591/ijece.v8i3.pp1432-1441.

Full text
Abstract:
For leakage current safety, Residual Current Device (RCD) has been well known. The purpose of this work is to make the employment of low price components to measure residual current feasible and the Residual Current Device (RCD) must to be taken into account because it is a well known device for leakage current safety. For this purpose, experiments employing the Helmholtz Coil Configuration were performed with the different current flow. Furthermore, the residual current was formulated and simulated through the software Easy Java Simulation (EJS). The results showed that it is possible to move
APA, Harvard, Vancouver, ISO, and other styles
4

Xiang Luo, Y. Du, X. H. Wang, and M. L. Chen. "Tripping Characteristics of Residual Current Devices Under Nonsinusoidal Currents." IEEE Transactions on Industry Applications 47, no. 3 (2011): 1515–21. http://dx.doi.org/10.1109/tia.2011.2125939.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Shvarts, Genrih. "Residual-current devices improper disconnection reasons." Energy-Safety and Energy-Economy 5 (October 2016): 31–36. http://dx.doi.org/10.18635/2071-2219-2016-4-31-36.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Slangen, T. M. H., B. R. F. Lustenhouwer, V. Cuk, and J. F. G. Cobben. "The Effects of High-Frequency Residual Currents on the Operation of Residual Current Devices." Renewable Energy and Power Quality Journal 19 (September 2021): 67–72. http://dx.doi.org/10.24084/repqj19.216.

Full text
Abstract:
This research investigates the effects of high frequency currents between 50 Hz and 150 kHz on the operation of Residual Current Devices (RCDs). Nowadays, the increasing amount of large power-electronic switching devices can be a source of both harmonics (<2 kHz) and supraharmonics (2-150 kHz) currents injected to the grid. This can have several effects and possibly lead to unwanted tripping of RCDs, due to high earth-currents that can be emitted by the devices. The question is if supraharmonics can also lead to misoperation or fail-to-operate conditions for the RCDs, potentially leading to
APA, Harvard, Vancouver, ISO, and other styles
7

Freschi, Fabio. "High-Frequency Behavior of Residual Current Devices." IEEE Transactions on Power Delivery 27, no. 3 (2012): 1629–35. http://dx.doi.org/10.1109/tpwrd.2012.2191423.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Erdei, Z., M. Horgos, C. Lung, A. Pop-Vadean, and R. Muresan. "Frequency behavior of the residual current devices." IOP Conference Series: Materials Science and Engineering 163 (January 2017): 012053. http://dx.doi.org/10.1088/1757-899x/163/1/012053.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Мажидов, Ахрор Уматулла Угли, and Мирзохид Абдушур Угли Эшмирзаев. "RESIDUAL CURRENT DEVICES (RCD) AND ITS APPLICATIONS." Научный Онлайн Журнал Интеграл 73 (May 1, 2022): 22–26. https://doi.org/10.5281/zenodo.6527558.

Full text
Abstract:
On the basis of regulatory documents, recommendations for ensuring power supply and features of its solution are given. A full-fledged life of modern society is unthinkable without the use of electric energy. The resulting interruptions of electricity supply to one degree or another paralyze the life of society, generating negative consequences that do not depend on the time frame and type of activity of members of society. All this determines the special importance of the problem of reliable power supply.The article can be used by specialists and designers to make design decisions and develop
APA, Harvard, Vancouver, ISO, and other styles
10

CZAPP, Stanislaw. "Residual current devices in electric vehicles charging installations." PRZEGLĄD ELEKTROTECHNICZNY 1, no. 2 (2024): 64–67. http://dx.doi.org/10.15199/48.2024.02.11.

Full text
APA, Harvard, Vancouver, ISO, and other styles
11

Czapp, Stanislaw, Hanan Tariq, and Slawomir Cieslik. "Behavior of Residual Current Devices at Earth Fault Currents with DC Component." Sensors 22, no. 21 (2022): 8382. http://dx.doi.org/10.3390/s22218382.

Full text
Abstract:
Low-voltage electrical installations are increasingly saturated with power electronic converters. Due to very high popularity of photovoltaic (PV) installations and the spread of electric vehicles (EV) as well as their charging installations, DC–AC and AC–DC converters are often found in power systems. The transformerless coupling of AC and DC systems via power electronic converters means that an electrical installation containing both these systems should be recognized from the point of view of earth fault current waveform shapes. In such installations, various shapes of the earth fault curre
APA, Harvard, Vancouver, ISO, and other styles
12

Li, You, Chuanfu Xia, Yuan Zhuang, Baoquan Liao, and Shuai Huang. "Research on residual current detection system of substation alternating current power supply." Journal of Physics: Conference Series 2108, no. 1 (2021): 012050. http://dx.doi.org/10.1088/1742-6596/2108/1/012050.

Full text
Abstract:
Abstract Residual current monitoring of substation is essential to prevent electrical fire and plays an important role in the safety of substation. This paper studied residual current detection technology of substation AC power supply, and proposed a residual current detection system composed of three devices: sensing terminal, management terminal and monitoring terminal. The design could solve some difficult problems such as the secondary line caused by equipment installation, fault wave recording, fault location analysis, and early warning based on analysis of big data. The study could impro
APA, Harvard, Vancouver, ISO, and other styles
13

Czapp, Stanislaw. "Residual current devices in installations with PV energy sources." PRZEGLĄD ELEKTROTECHNICZNY 1, no. 12 (2022): 102–6. http://dx.doi.org/10.15199/48.2022.12.25.

Full text
APA, Harvard, Vancouver, ISO, and other styles
14

Nikolsky, O. К., and T. M. Khalina. "Development of a Range of Modified Multifunctional Residual Current Systems and Their Industrial Implementation." IOP Conference Series: Materials Science and Engineering 1211, no. 1 (2022): 012020. http://dx.doi.org/10.1088/1757-899x/1211/1/012020.

Full text
Abstract:
Abstract The developments of the AltSTU have been reviewed in the area of creating a new technology for preventing technogenic hazards based on the residual current devices. The residual current devices are intended for protecting people from electric shock in case of contact with conductive parts of the electric appliances and shall facilitate reduction of fire risks caused by a prolonged flow of leakage currents and fault currents resulting from them. The results of creating different modifications of protective trip circuits and their industrial use are provided.
APA, Harvard, Vancouver, ISO, and other styles
15

Czapp, Stanislaw. "Requirements for Residual Current Devices Intended for Electric Vehicle Charging Systems." AUTOMATYKA, ELEKTRYKA, ZAKLOCENIA 14, no. 34(54)20233 (2023): 10–20. http://dx.doi.org/10.17274/aez.2023.54.01.

Full text
Abstract:
The properties of residual current devices have been presented from the point of view of their ability to detect a specific shape of the residual current waveform. Moreover, the standard requirements relating to residual current protection used in electric vehicle charging installations have been pointed out. The operating characteristics of the IC-CPD and RDC-DD protections, which are intended for charging electric vehicles in mode 2 and mode 3, respectively, have been also discussed.
APA, Harvard, Vancouver, ISO, and other styles
16

Möller, Friedemann, Ana Maria Blanco, and Jan Meyer. "Characteristic leakage current of household devices and their impact on the tripping behaviour of residual current devices." Electric Power Systems Research 214 (January 2023): 108832. http://dx.doi.org/10.1016/j.epsr.2022.108832.

Full text
APA, Harvard, Vancouver, ISO, and other styles
17

Mitolo, Massimo. "Shock Hazard in the Presence of Protective Residual-Current Devices." IEEE Transactions on Industry Applications 46, no. 4 (2010): 1552–57. http://dx.doi.org/10.1109/tia.2010.2051068.

Full text
APA, Harvard, Vancouver, ISO, and other styles
18

Czapp, Stanislaw. "Testing Sensitivity of A-Type Residual Current Devices to Earth Fault Currents with Harmonics." Sensors 20, no. 7 (2020): 2044. http://dx.doi.org/10.3390/s20072044.

Full text
Abstract:
In many applications, modern current-using equipment utilizes power electronic converters to control the consumed power and to adjust the motor speed. Such equipment is used both in industrial and domestic installations. A characteristic feature of the converters is producing distorted earth fault currents, which contain a wide spectrum of harmonics, including high-order harmonics. Nowadays, protection against electric shock in low-voltage power systems is commonly performed with the use of residual current devices (RCDs). In the presence of harmonics, the RCDs may have a tripping current sign
APA, Harvard, Vancouver, ISO, and other styles
19

Lee, Bok-Hee, Hee-Yeoul Park, Gun-Jin Shin, Gwan-Young Bae, Chun-Hyoung Ryu, and Kang-Hee Lee. "Protection Coordination Associated with Connection Location of Residual Current Devices and Surge Protective Devices." Journal of the Korean Institute of Illuminating and Electrical Installation Engineers 27, no. 3 (2013): 100–106. http://dx.doi.org/10.5207/jieie.2013.27.3.100.

Full text
APA, Harvard, Vancouver, ISO, and other styles
20

Zhang, Bin-bin, Song Gao, Chao-bo Chen, Ji-chao Li, and Xue-qin Bi. "A Semiconductor Bridge Electrical Explosive Device Online Firing Quality Identification Algorithm." Mathematical Problems in Engineering 2020 (November 20, 2020): 1–7. http://dx.doi.org/10.1155/2020/1638705.

Full text
Abstract:
When qualified explosive devices fire the explosive agent unsuccessfully, on-site testers cannot diagnose fast and accurately whether it is the firing quality problem of the electrical explosive devices or explosive agent by using traditional test methods. And, if the explosive agent is fired unsuccessfully, generally, the only way is to test the explosive device by on-site testers themselves. In order to protect the on-site testers’ safety, this paper proposes an electrical explosive device firing quality identification algorithm based on HHT (Hilbert–Huang transform) of the explosive time se
APA, Harvard, Vancouver, ISO, and other styles
21

Czapp, Stanislaw, and Hanan Tariq. "Behavior of Residual Current Devices at Frequencies up to 50 kHz." Energies 14, no. 6 (2021): 1785. http://dx.doi.org/10.3390/en14061785.

Full text
Abstract:
The use of residual current devices (RCDs) is obligatory in many types of low-voltage circuits. They are devices that ensure protection against electric shock in the case of indirect contact and may ensure additional protection in the case of direct contact. For the latter purpose of protection, only RCDs of a rated residual operating current not exceeding 30 mA are suitable. Unfortunately, modem current-using equipment supplied via electronic converters with a pulse width modulation produces earth fault currents composed of high-frequency components. Frequency of these components may have eve
APA, Harvard, Vancouver, ISO, and other styles
22

Lee, Bok-Hee, Hoe-Gu Kim, Hee-Yeoul Park, and Chang-Hwan Ahn. "Protection coordination between residual current device and surge protective devices in low-voltage consumer's installations." Journal of the Korean Institute of Illuminating and Electrical Installation Engineers 27, no. 6 (2013): 75–81. http://dx.doi.org/10.5207/jieie.2013.27.6.075.

Full text
APA, Harvard, Vancouver, ISO, and other styles
23

Almeida, Thiago Augusto Silva de, Ruth Pastora Saraiva Leão, and Raimundo Furtado Sampaio. "Impact of Harmonic Current on Residual Current Devices Performance in a Steel Making Plant." Journal of Engineering Research 3, no. 36 (2023): 2–10. http://dx.doi.org/10.22533/at.ed.31733623251010.

Full text
APA, Harvard, Vancouver, ISO, and other styles
24

Yuan, Zhi Jian. "A New Method of the Touch/Leakage Protection without Dead-Zone Considering the Phase Characteristics." Advanced Materials Research 1065-1069 (December 2014): 3395–99. http://dx.doi.org/10.4028/www.scientific.net/amr.1065-1069.3395.

Full text
Abstract:
After investigating the residual current protection and its major deficiencies, it is found out that the touch/Leakage current could be separated from the total residual current by the current separation technology , which is based on the phase relationship between normal residual current and touch/leakage current. A novel leakage current protection principle without protection dead-zone is proposed .The proposed method, which is put into practice on DSP , proves to be accurate and feasible in digital simulations. Compared to the existing techniques based on the residual current amplitude or i
APA, Harvard, Vancouver, ISO, and other styles
25

Arnautalić, Sead, Ebedija Hajder Mujčinagić, and Srđan Petrović. "Influence of Current Transformer Saturation on Numerical Protection Relays – A Case Study of Circuit Breaker Failure Protection." B&H Electrical Engineering 15, no. 2 (2021): 78–85. http://dx.doi.org/10.2478/bhee-2021-0021.

Full text
Abstract:
Abstract A low impedance fault on a transmission line causes large fault currents that can lead current transformers in the switchyard that supplies the fault to saturation. If the fast automatic reclosing is implemented the current transformers additionally enter saturation. After the definitive trip, the residual magnetic energy in the current transformers is discharged via secondary circuits. The measuring inputs of the protective devices are connected to the secondary of the current transformers, and if the current is large and lasts long enough consequence can be an unwanted operation of
APA, Harvard, Vancouver, ISO, and other styles
26

Yokoyama, T., N. Kinjo, Y. Wakashima, and Y. Miyadera. "The Effect of the Polymer Coating on Residual Current of Mos Devices." IEEE Transactions on Electrical Insulation EI-20, no. 3 (1985): 557–60. http://dx.doi.org/10.1109/tei.1985.348782.

Full text
APA, Harvard, Vancouver, ISO, and other styles
27

Czaja, Pawel. "Influence of the Design of a Residual Current Device on Its Break Time." Energies 15, no. 23 (2022): 9054. http://dx.doi.org/10.3390/en15239054.

Full text
Abstract:
Residual current devices (RCDs) are devices that can provide very good protection measures against electric shock. Yet, under certain circumstances, they can cause unnecessary and unexpected switching off of power in the protected circuits. The main component that determines the properties of an RCD is the summation current transformer. In recently produced RCDs, whose operation is independent from the installation voltage, the summation transformer, apart from detection of the residual current, has yet another task: it must also provide an appropriate energy value to the electromagnetic relea
APA, Harvard, Vancouver, ISO, and other styles
28

Wang, Lin Yuan. "The Application Research of Current Protection Device in Low-Voltage Rural Grid." Applied Mechanics and Materials 644-650 (September 2014): 3675–77. http://dx.doi.org/10.4028/www.scientific.net/amm.644-650.3675.

Full text
Abstract:
Current protective device against direct and indirect electric shock as well as effective protection against electrical fires has been widely used in the rural power grid, but there is also a more prominent issue. Residual current protection device in use often appearing malfunction, tripping phenomenon has seriously affected the security and stability and reliability of power supply and low voltage distribution systems. In this paper, it should be from a low-voltage distribution systems and wiring protection devices, power grid maintenance operation, standardized management products, technica
APA, Harvard, Vancouver, ISO, and other styles
29

PULIDO PATÓN, A. "CURRENT PROSPECTS FOR ASTROD INERTIAL SENSOR." International Journal of Modern Physics D 17, no. 07 (2008): 941–63. http://dx.doi.org/10.1142/s0218271808012620.

Full text
Abstract:
The Astrodynamical Space Test of Relativity using Optical Devices (ASTROD) is a multi-purpose relativity mission concept. ASTROD's scientific goals are the measurement of relativistic and solar system parameters to unprecedented precision, and the detection and observation of low-frequency gravitational waves to frequencies down to 5 × 10-6 Hz. To accomplish its goals, ASTROD will employ a constellation of drag-free satellites, aiming for a residual acceleration noise of (0.3-1) × 10-15 m s-2 Hz-1/2 at 0.1 mHz. Noise sources and strategies for improving present acceleration noise levels are re
APA, Harvard, Vancouver, ISO, and other styles
30

Pichuev, A. V., and V. L. Petrov. "Equivalent circuit for mine power distribution systems for the analysis of insulation leakage current." Gornye nauki i tekhnologii = Mining Science and Technology (Russia) 8, no. 1 (2023): 78–86. http://dx.doi.org/10.17073/2500-0632-2023-01-72.

Full text
Abstract:
Successful mining businesses rely heavily on the safety and reliability of their mine power distribution systems. Mine power distribution systems are designed to withstand an aggressive environment with a range of hazards. The harsh operating conditions require improvement to personnel protection systems through the study and simulation of the electric network’s normal and emergency operations. The purpose of this study is to assess insulation leakage current using an equivalent circuit of a mine power distribution system. The simulation identified the key properties of the equivalent circuit
APA, Harvard, Vancouver, ISO, and other styles
31

Bai, Yunpeng, Xiangke Zhang, Yajing Wang, Lei Wang, Qinqin Wei, and Wenlei Zhao. "Residual current detection method based on improved VMD-BPNN." PLOS ONE 19, no. 2 (2024): e0289129. http://dx.doi.org/10.1371/journal.pone.0289129.

Full text
Abstract:
To further enhance the residual current detection capability of low-voltage distribution networks, an improved adaptive residual current detection method that combines variational modal decomposition (VMD) and BP neural network (BPNN) is proposed. Firstly, the method employs the envelope entropy as the adaptability function, optimizes the [k, ɑ] combination value of the VMD decomposition using the bacterial foraging-particle swarm algorithm (BFO-PSO), and utilizes the interrelation number R as the classification index with the Least Mean Square Algorithm (LMS) to classify, filter, and extract
APA, Harvard, Vancouver, ISO, and other styles
32

Ibrahim Jabbar, Feryal, Dur Muhammad Soomro, Mohd Noor bin Abdullah, et al. "Optimize single line to ground fault detection in distribution grid power system using artificial bee colony." Indonesian Journal of Electrical Engineering and Computer Science 31, no. 3 (2023): 1286. http://dx.doi.org/10.11591/ijeecs.v31.i3.pp1286-1294.

Full text
Abstract:
The most common power system (PS) distribution network fault, single lineto-ground fault (SLGF), causes residual current (I res) to start an electrical arc and high voltage (HV) three times the rated voltage in other healthy phases. HV from capacitive currents (IC) damages cable insulation and PS appliances. Peterson The neutral point coil (PC) reduces (I res) and extinguishes the electric arc, but the fault current (I fault) remains below the protection devices' threshold. Operations and equipment are riskier. PC adaptive eliminates electrical arcs, making the network safer. This paper detect
APA, Harvard, Vancouver, ISO, and other styles
33

Xu, S., S. Zhang, J. D. Kirch та ін. "∼8.5 μm-emitting InP-based quantum cascade lasers grown on GaAs by metal-organic chemical vapor deposition". Applied Physics Letters 121, № 17 (2022): 171103. http://dx.doi.org/10.1063/5.0122272.

Full text
Abstract:
Room-temperature, pulsed-operation lasing of 8.5 μm-emitting InP-based quantum cascade lasers (QCLs), with low threshold-current density and watt-level output power, is demonstrated from structures grown on (001) GaAs substrates by metal-organic chemical vapor deposition. Prior to growing the laser structure, which contains a 35-stage In0.53Ga0.47As/In0.52Al0.48As lattice-matched active-core region, a ∼2 μm-thick nearly fully relaxed InP buffer with strained 1.6 nm-thick InAs quantum-dot-like dislocation-filter layers was grown. A smooth terminal buffer-layer surface, with roughness as low as
APA, Harvard, Vancouver, ISO, and other styles
34

Wen, Qiaozheng, Shuguang Song, Jiaxuan Lei, Qingxiao Du, and Wenzhong Ma. "Analysis and Detection of Four Typical Arm Current Measurement Faults in MMC." Energies 18, no. 14 (2025): 3727. https://doi.org/10.3390/en18143727.

Full text
Abstract:
Circulating current control is a critical part of the Modular Multilevel Converter (MMC) control system. Existing control methods rely on arm current information obtained from complex current measurement devices. However, these devices are susceptible to failures, which can lead to distorted arm currents, increased peak arm current values, and higher losses. In extreme cases, this can result in system instability. This paper first analyzes four typical arm current measurement faults, i.e., constant gain faults, amplitude deviation faults, phase shift faults, and stuck faults. Then, a Kalman Fi
APA, Harvard, Vancouver, ISO, and other styles
35

Mukwata, Wonder, and Josiah Munda. "Analysis of 3 kV DC Contact Line High-Speed Circuit Breaker Unit Protection Scheme Limitations." International Journal of Electronics and Electrical Engineering 10, no. 1 (2022): 7–13. http://dx.doi.org/10.18178/ijeee.10.1.7-13.

Full text
Abstract:
The High-Speed Circuit Breaker (HSCB) is a de-facto electro-mechanical contact line protection device employed in the 3 kV DC traction power supply system. The breakers installed at the terminal ends of the contact line make a unit protection scheme configuration. While the HSCBs seem to trip under fault conditions, there is an unknown source that keeps on supplying residual current into the faults. This necessitates some explanation of the source of energy of the continual flow of residual energy. This paper makes an analysis of the limitations in the HSCB unit protection scheme using MATLAB
APA, Harvard, Vancouver, ISO, and other styles
36

Feryal, Ibrahim Jabbar, Muhammad Soomro Dur, Noor Abdullah Mohd, et al. "Optimize single line to ground fault detection in distribution grid power system using artificial bee colony." Optimize single line to ground fault detection in distribution grid power system using artificial bee colony 31, no. 3 (2023): 1286–94. https://doi.org/10.11591/ijeecs.v31.i3.pp1286-1294.

Full text
Abstract:
The most common power system (PS) distribution network fault, single lineto-ground fault (SLGF), causes residual current (I res) to start an electrical arc and high voltage (HV) three times the rated voltage in other healthy phases. HV from capacitive currents (IC) damages cable insulation and PS appliances. Peterson The neutral point coil (PC) reduces (I res) and extinguishes the electric arc, but the fault current (I fault) remains below the protection devices' threshold. Operations and equipment are riskier. PC adaptive eliminates electrical arcs, making the network safer. This paper de
APA, Harvard, Vancouver, ISO, and other styles
37

Czapp, Stanislaw, and Kornel Borowski. "Verification of safety in low-voltage power systems without nuisance tripping of residual current devices." Electric Power Systems Research 172 (July 2019): 260–68. http://dx.doi.org/10.1016/j.epsr.2019.03.027.

Full text
APA, Harvard, Vancouver, ISO, and other styles
38

Omori, Tomoki, Masahiro Nakanishi, and Daisuke Tashima. "High-Temperature Degradation Tests on Electric Double-Layer Capacitors: The Effect of Residual Voltage on Degradation." Materials 14, no. 6 (2021): 1520. http://dx.doi.org/10.3390/ma14061520.

Full text
Abstract:
The demand for electric double-layer capacitors, which have high capacity and are maintenance-free, for use in a variety of devices has increased. Nevertheless, it is important to know the degradation behavior of these capacitors at high temperatures because they are expected to be used in severe environments. Therefore, degradation tests at 25 °C and 80 °C were carried out in the current study to analyze the degradation behavior. Steam-activated carbon, Ketjen black, and PTFE were used as the electrodes, conductive material, and binder, respectively, and KOH was used as the electrolyte. The i
APA, Harvard, Vancouver, ISO, and other styles
39

Lester, Bruce R., Nicole P. Boser, Keith Miller, et al. "Reprocessing and Sterilization of Single-Use Electrophysiological Catheters: Removal of Organic Carbon and Protein Surface Residues." Journal of AOAC INTERNATIONAL 92, no. 4 (2009): 1165–73. http://dx.doi.org/10.1093/jaoac/92.4.1165.

Full text
Abstract:
Abstract Although evidence to date indicates that reprocessing electrophysiological (EP) catheters results in clean, sterile devices, some concerns persist with regard to the risk of residual contamination. We examined the ability of a defined reprocessing procedure coupled with a validated sterilization protocol to remove organic carbon and protein residues from worst-case soiled EP catheters resulting in clean, sterile devices. Total organic carbon (TOC) determinations indicated that detergent residues on reprocessed used catheters were nominal and significantly lower than organic carbon lev
APA, Harvard, Vancouver, ISO, and other styles
40

Kremer, Terra A., Daniel Olsen, Chad Summers, et al. "Assessing Detergent Residuals for Reusable Device Cleaning Validations." Biomedical Instrumentation & Technology 55, no. 4 (2021): 165–70. http://dx.doi.org/10.2345/0890-8205-55.4.165.

Full text
Abstract:
Abstract Cleaning chemistries are detergent-based formulations that are used during the processing of reusable medical devices. Manufacturers are responsible for demonstrating the safety of cleaning formulations when they are used during a device processing cycle, including the risk of device-associated cytotoxicity over the concentration ranges for recommended use and rinsing during cleaning. However, no regulation currently exists requiring manufacturers to demonstrate such safety. Although manufacturers' safety data sheets (SDSs) provide information on the safe use of chemicals for users, t
APA, Harvard, Vancouver, ISO, and other styles
41

Lee, Hoon Jeong, Arlene Chiu, Yida Lin, Sreyas Chintapalli, Serene Kamal, and Susanna Mitrani Thon. "(Invited) Parameter Prediction in Colloidal Quantum Dot Solar Cells Using Residual Neural Networks Trained on Experimental Data." ECS Meeting Abstracts MA2024-01, no. 23 (2024): 1375. http://dx.doi.org/10.1149/ma2024-01231375mtgabs.

Full text
Abstract:
Colloidal quantum dots (CQDs) are an attractive third-generation material for photovoltaics, especially as infrared materials for multi-junction solar cells. Characterization and materials parameter prediction both play a critical role in the rising efficiencies in this field. However, there are numerous materials properties that need to be measured in order to fully characterize a device, leading to high research costs and slow development times. Here, we leverage recent advancements in machine learning (ML), along with a recently-demonstrated multimodal spectral characterization method [1],
APA, Harvard, Vancouver, ISO, and other styles
42

Lee, Hyo Soo, Hai Joong Lee, Sung Chul Lim та Hyouk Chon Kwon. "Thermophysical Behavior of Micro Void in μ-Via of Microelectronic Substrate during Reliability Test". Advanced Materials Research 26-28 (жовтень 2007): 1261–64. http://dx.doi.org/10.4028/www.scientific.net/amr.26-28.1261.

Full text
Abstract:
The μ-via in microelectronic substrate should have multiple purposes, one of them is to allow to the path of signal or current from electronic devices. The micro void can be easily formed in μ-via because μ-vias are filled with a screen printing process and the size of via is small. The residual void has been known as crack initiation of copper layer during a reliability test. The solder resist filling process and the behavior of a residual void in μ-vias were investigated. The void extraction process was very effective comparing with the conventional process to remove a residual void. As extr
APA, Harvard, Vancouver, ISO, and other styles
43

Slangen, Tim, Thijs van Wijk, Vladimir Ćuk, and Sjef Cobben. "The Propagation and Interaction of Supraharmonics from Electric Vehicle Chargers in a Low-Voltage Grid." Energies 13, no. 15 (2020): 3865. http://dx.doi.org/10.3390/en13153865.

Full text
Abstract:
The recent increase in large converter-based devices like electric vehicles and photovoltaics increases supraharmonic emissions in low-voltage grids, potentially affecting customer equipment and the grid. This paper aims to give an overview of the different factors influencing supraharmonic emissions from electric vehicles and studies the propagation of supraharmonic currents through a small, low-voltage grid. Measurements in an unique lab representing a possible future household gave valuable insight on the possible developments in primary and secondary supraharmonic emissions in a convention
APA, Harvard, Vancouver, ISO, and other styles
44

Bosiers, Marc, Koen Deloose, Rodrigo Moreialvar, Jurgen Verbist, and Patrick Peeters. "Current status of infrapopliteal artery stenting in patients with critical limb ischemia." Jornal Vascular Brasileiro 7, no. 3 (2008): 248–55. http://dx.doi.org/10.1590/s1677-54492008000300010.

Full text
Abstract:
Due to the fear that early thrombosis and late luminal loss resulting from intimal hyperplasia might impede sustained patency of small-caliber arteries, such as those of the infrapopliteal bed, stent implantation in below-knee vessels remains controversial and is generally reserved for cases with a suboptimal outcome after percutaneous transluminal angioplasty (i.e. > 50% residual stenosis, flow-limiting dissection). Although evidence starts to build, favoring the use of stenting in the tibial area, results of well-conducted randomized controlled trials have to be awaited to change this str
APA, Harvard, Vancouver, ISO, and other styles
45

Shao, Li Min, Meng Zhang, and Song Huai Du. "Research on the Key Factors of Mis-Operations and Correct Operations of the Residual Current Operated Protective Device." Applied Mechanics and Materials 721 (December 2014): 599–602. http://dx.doi.org/10.4028/www.scientific.net/amm.721.599.

Full text
Abstract:
Residual Current Operated Devices (RCDs) are the protective instruments of safe operation for power system. RCDs are important components for safety against indirect contacts in low voltage installations, and employed for protection against electric shock and earth faults. In order to develop a new rule of RCD tripping directly by the human body current while shocking, it is very important to detect and identify the contact current of the human body in the summation leakage current on the low-voltage electric power grid. The new methods can solve the above problems of RCD. So, the tripping cha
APA, Harvard, Vancouver, ISO, and other styles
46

Islam, Jahidul, Han Shao, Md Mizanur Rahman Badal, Kafil M. Razeeb, and Mamun Jamal. "Pencil graphite as electrode platform for free chlorine sensors and energy storage devices." PLOS ONE 16, no. 3 (2021): e0248142. http://dx.doi.org/10.1371/journal.pone.0248142.

Full text
Abstract:
Multifunctional and low-cost electrode materials are desirable for the next-generation sensors and energy storage applications. This paper reports the use of pencil graphite as an electrode for dual applications that include the detection of free residual chlorine using electro-oxidation process and as an electrochemical energy storage cathode. The pencil graphite is transferred to cellulose paper by drawing ten times and applied for the detection of free residual chlorine, which shows a sensitivity of 27 μA mM-1 cm-2 with a limit of detection of 88.9 μM and linearity up to 7 mM. The sample ma
APA, Harvard, Vancouver, ISO, and other styles
47

Yu, Yong, Changhua Hu, Xiaosheng Si, and Jianxun Zhang. "Degradation Data-Driven Remaining Useful Life Estimation in the Absence of Prior Degradation Knowledge." Journal of Control Science and Engineering 2017 (2017): 1–11. http://dx.doi.org/10.1155/2017/4375690.

Full text
Abstract:
Recent developments in prognostic and health management have been targeted at utilizing the observed degradation signals to estimate residual life distributions. Current degradation models mainly focus on a population of “identical” devices or an individual device with population information, not a single component in the absence of prior degradation knowledge. However, the fast development of science and technology provides us with many kinds of new systems, and we just have the real-time monitoring information to analyze the reliability for them. The fusion algorithm presented herein address
APA, Harvard, Vancouver, ISO, and other styles
48

Sutaria, Jil, Ángela Espín-Delgado, and Sarah Rönnberg. "Measurements and modeling of the frequency behavior of residual current devices- from 4 Hz to 40 kHz." Electric Power Systems Research 209 (August 2022): 108052. http://dx.doi.org/10.1016/j.epsr.2022.108052.

Full text
APA, Harvard, Vancouver, ISO, and other styles
49

Spina, Michele, Filippo Naso, Irene Zancan, Laura Iop, Monica Dettin, and Gino Gerosa. "Biocompatibility Issues of Next Generation Decellularized Bioprosthetic Devices." Conference Papers in Science 2014 (May 12, 2014): 1–6. http://dx.doi.org/10.1155/2014/869240.

Full text
Abstract:
With respect to the limited lifespan of glutaraldehyde-treated bioprostheses (BHVs) to date there is almost no alternative when heart valve replacement surgery is required and most advanced current research attempts to develop tissue engineered valve scaffolds to be implanted in vivo or after in vitro preconditioning and dynamic seeding with host cells. However the clinical outcomes of grafting detergent-based cell-depleted tissue engineered xenogeneic constructs are still controversial. Insufficient quantitative evaluations performed at preclinical level about the residual content of xenogene
APA, Harvard, Vancouver, ISO, and other styles
50

Ayoub, Kamal, Leonard Harris, and Bill Thompson. "Determination of Low-Level Residual Ethylene Oxide by Using Solid-Phase Microextraction and Gas Chromatography." Journal of AOAC INTERNATIONAL 85, no. 6 (2002): 1205–9. http://dx.doi.org/10.1093/jaoac/85.6.1205.

Full text
Abstract:
Abstract Current methods of analysis for ethylene oxide (EO) in medical devices include headspace and simulated-use extractions followed by gas chromatography with either a packed or a capillary column. The quantitation limits are about 0.5–1.0 μg/g for a packed column and about 0.1–0.2 μg/g for a capillary column. The current allowable levels of EO on medical devices sterilized with EO gas as outlined in International Organization for Standardization (ISO) 10993-7 may be significantly reduced from current levels by applying the ISO Draft International Standard 10993-17 method for establishing
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!