To see the other types of publications on this topic, follow the link: Scanning Laser Vibrometer.

Dissertations / Theses on the topic 'Scanning Laser Vibrometer'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 18 dissertations / theses for your research on the topic 'Scanning Laser Vibrometer.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

Acharya, Dabit. "COMPARATIVE EXPERIMENTAL STUDIES FOR GLOBAL DAMAGE DETECTION IN PLATES USING THE SCANNING LASER VIBROMETER TECHNIQUES." University of Akron / OhioLINK, 2006. http://rave.ohiolink.edu/etdc/view?acc_num=akron1155079600.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Martarelli, Milena. "Exploiting the laser scanning facility for vibration measurements." Thesis, Imperial College London, 2001. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.248035.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Blotter, Jonathan D. "Structural energy and power flow using a scanning laser Doppler vibrometer." Diss., This resource online, 1996. http://scholar.lib.vt.edu/theses/available/etd-06062008-151157/.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Rajm, Martin. "Laserový vibrometr s 2D rozmítáním." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2012. http://www.nusl.cz/ntk/nusl-219813.

Full text
Abstract:
This thesis deals in the theoretical part with the non-contact vibration measurement by single point Laser Doppler vibrometer and it concretes constructions used in practice. It deals also with the possibilities of the laser beam scanning to measure the vibrations in the plane and there are also listed suitable-commercial systems for this solution. Mentioned sweep is immediately necessary for 2D scanning vibrometer construction. In the practical part, the single-point laser vibrometer OFV-5000 was expanded by scanning galvo system, supplemented by a measuring cards for signal acquisition from
APA, Harvard, Vancouver, ISO, and other styles
5

Strean, R. Flynt. "Characterization of laser noise in free-free beam structures using a Scanning Laser Doppler Vibrometer." Thesis, This resource online, 1995. http://scholar.lib.vt.edu/theses/available/etd-02132009-171026/.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Jin, Si. "Structural damage detection using higher-order finite elements and a scanning laser vibrometer /." free to MU campus, to others for purchase, 2000. http://wwwlib.umi.com/cr/mo/fullcit?p9974641.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Zeng, Xiandi. "The estimation and statistical inferences of the position and orientation of a scanning laser Doppler vibrometer." Diss., This resource online, 1994. http://scholar.lib.vt.edu/theses/available/etd-10302008-063011/.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Manwill, Daniel Alan. "Scanning Laser Registration and Structural Energy Density Based Active Structural Acoustic Control." BYU ScholarsArchive, 2010. https://scholarsarchive.byu.edu/etd/2396.

Full text
Abstract:
To simplify the measurement of energy-based structural metrics, a general registration process for the scanning laser doppler vibrometer (SLDV) has been developed. Existing registration techniques, also known as pose estimation or position registration, suffer from mathematical complexity, instrument specificity, and the need for correct optimization initialization. These difficulties have been addressed through development of a general linear laser model and hybrid registration algorithm. These are applicable to any SLDV and allow the registration problem to be solved using straightforward ma
APA, Harvard, Vancouver, ISO, and other styles
9

Salman, Muhammad. "Continuous scanning laser doppler vibrometry for synchronized array measurements: applications to non-contact sensing of human body vibrations." Diss., Georgia Institute of Technology, 2012. http://hdl.handle.net/1853/45792.

Full text
Abstract:
Laser Doppler Vibrometry (LDV) is a non-contact technique for sensing surface vibrations. Traditionally, LDV uses one or more fixed beams to measure the vibrational velocity of specific points and orientations. In order to measure an angular velocity at least two laser beams are required. Instead, this research proposes to develop a Continuous Scanning Laser Doppler Vibrometer (CSLDV) technique, based on a single laser beam continuously sweeping the area of interest using a scanning mirror. Linear scans allow the measurement of normal and angular velocity while circular scans allow the mea
APA, Harvard, Vancouver, ISO, and other styles
10

Bornitz, Matthias, Thomas Zahnert, Hans-Jürgen Hardtke, and Karl-Bernd Hüttenbrink. "Identification of Parameters for the Middle Ear Model." Saechsische Landesbibliothek- Staats- und Universitaetsbibliothek Dresden, 2014. http://nbn-resolving.de/urn:nbn:de:bsz:14-qucosa-135790.

Full text
Abstract:
This paper presents a method of parameter identification for a finite-element model of the human middle ear. The parameter values are estimated using a characterization of the difference in natural frequencies and mode shapes of the tympanic membrane between the model and the specimens. Experimental results were obtained from temporal bone specimens under sound excitation (300–3,000 Hz). The first 3 modes of the tympanic membrane could be observed with a laser scanning vibrometer and were used to estimate the stiffness parameters for the orthotropic finite-element model of the eardrum. A furth
APA, Harvard, Vancouver, ISO, and other styles
11

Bornitz, Matthias, Thomas Zahnert, Hans-Jürgen Hardtke, and Karl-Bernd Hüttenbrink. "Identification of Parameters for the Middle Ear Model." Karger, 1999. https://tud.qucosa.de/id/qucosa%3A27677.

Full text
Abstract:
This paper presents a method of parameter identification for a finite-element model of the human middle ear. The parameter values are estimated using a characterization of the difference in natural frequencies and mode shapes of the tympanic membrane between the model and the specimens. Experimental results were obtained from temporal bone specimens under sound excitation (300–3,000 Hz). The first 3 modes of the tympanic membrane could be observed with a laser scanning vibrometer and were used to estimate the stiffness parameters for the orthotropic finite-element model of the eardrum. A furth
APA, Harvard, Vancouver, ISO, and other styles
12

Lu, Kan. "Dynamics Based Damage Detection of Plate-Type Structures." University of Akron / OhioLINK, 2005. http://rave.ohiolink.edu/etdc/view?acc_num=akron1133818717.

Full text
APA, Harvard, Vancouver, ISO, and other styles
13

Jones, Cameron Bennion. "Development and Validation of a Vibration-Based Sound Power Measurement Method." BYU ScholarsArchive, 2019. https://scholarsarchive.byu.edu/etd/9260.

Full text
Abstract:
The International Organization for Standardization (ISO) provides no vibration-based sound power measurement standard that provides Precision (Grade 1) results. Current standards that provide Precision (Grade 1) results require known acoustic environments or complex setups. This thesis details the Vibration Based Radiation Mode (VBRM) method as one approach that could potentially be used to develop a Precision (Grade 1) standard. The VBRM method uses measured surface velocities of a structure and combines them with the radiation resistance matrix to calculate sound power. In this thesis the VB
APA, Harvard, Vancouver, ISO, and other styles
14

Himes, Benjamin John. "Development and Analysis of a Vibration Based Sleep Improvement Device." BYU ScholarsArchive, 2020. https://scholarsarchive.byu.edu/etd/9168.

Full text
Abstract:
Many research studies have analyzed the effect that whole-body vibration (WBV) has on sleep, and some have sought to use vibration to treat sleep disorders such as insomnia. It has been shown that low frequencies (f < 2Hz) are generally sleep inducing, but oscillations of this frequency are typically difficult to achieve using electromagnetic vibration drives. In the research that has been performed, optimal vibration parameters have not been determined, and the effects of multiple vibration sources vibrating at different frequencies to induce a low frequency traveling wave have not been explo
APA, Harvard, Vancouver, ISO, and other styles
15

Abdullah, A. B. M. "Development of a Closed-loop Resonant Fatigue Testing Methodology and Experimental Life Test of Aluminum Alloy." University of Akron / OhioLINK, 2010. http://rave.ohiolink.edu/etdc/view?acc_num=akron1289328504.

Full text
APA, Harvard, Vancouver, ISO, and other styles
16

Fekrmandi, Hadi. "Development of New Structural Health Monitoring Techniques." FIU Digital Commons, 2015. http://digitalcommons.fiu.edu/cgi/viewcontent.cgi?article=2923&context=etd.

Full text
Abstract:
During the past two decades, many researchers have developed methods for the detection of structural defects at the early stages to operate the aerospace vehicles safely and to reduce the operating costs. The Surface Response to Excitation (SuRE) method is one of these approaches developed at FIU to reduce the cost and size of the equipment. The SuRE method excites the surface at a series of frequencies and monitors the propagation characteristics of the generated waves. The amplitude of the waves reaching to any point on the surface varies with frequency; however, it remains consistent as lon
APA, Harvard, Vancouver, ISO, and other styles
17

Lavergne, Thomas. "Modélisation analytique et caractérisation expérimentale de microphones capacitifs en hautes fréquences : étude des couches limites thermiques, effets des perforations de l’électrode arrière sur la déformée de membrane." Thesis, Le Mans, 2011. http://www.theses.fr/2011LEMA1020/document.

Full text
Abstract:
Les microphones capacitifs sont des transducteurs réciproques dont les qualités (sensibilité, bande passante et tenue dans le temps) en font des instruments de mesure performants. Couramment utilisés jusqu’à présent en récepteurs dans l’air à pression atmosphérique et à température ambiante, dans la gamme de fréquences audibles, ils sont correctement caractérisés dans ce cadre depuis près de trente ans. Mais aujourd’hui, leur miniaturisation (par procédé MEMS) et leur usage nouveau en métrologie fine (en récepteurs comme en émetteurs) - qui exigent une connaissance précise de leur comportement
APA, Harvard, Vancouver, ISO, and other styles
18

Venkatesh, Kadbur Prabhakar Rao. "Experimental Studies on Extremely Small Scale Vibrations of Micro-Scale Mechanical and Biological Structures." Thesis, 2017. http://etd.iisc.ernet.in/2005/3541.

Full text
Abstract:
Experimental vibration analysis of mechanical structures is a well established field.Plenty of literature exists on macro scale structures in the fields of civil, mechanical and aerospace engineering, but the study of vibrations of micro scale structures such as MEMS, liquid droplets, and biological cells is relatively new. For such structures, the amplitudes of vibration are typically in nanometeror sub-nanometer range and the frequencies are in KHz to MHz range depending upon the dimensions of the structure. In our study, we use a scanningLaser Doppler Vibrometer (LDV) to measure the vibrat
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!