To see the other types of publications on this topic, follow the link: Scintilační detektor.

Dissertations / Theses on the topic 'Scintilační detektor'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 23 dissertations / theses for your research on the topic 'Scintilační detektor.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

Tihlaříková, Eva. "Scintilační detektor SE pro EREM." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2009. http://www.nusl.cz/ntk/nusl-217869.

Full text
Abstract:
This project deals with the theme of environmental scanning electron microscopy (EREM). This method allows the examination of insulators and wet specimens without pretreatment and modification like drying and metallization. The principle of this method consists in using higher pressure in a specimen chamber. The pressure is within the range of 100 – 200 Pa. However, the pressure in the specimen chamber restricts the signal detection interference. The objective of the work is to explore the possibility of interference in secondary electron route detection by way of electrostatic field. The electrostatic field was realized with the system consisting of four electrodes located in front of the scintillation detector. It should have interfered the secondary electron´s trajectory to the detector chamber. The optimization of voltage on the electrodes was made by simulation program called SIMION. The simulation results were experimentally verified with laboratory EREM.
APA, Harvard, Vancouver, ISO, and other styles
2

Čudek, Pavel. "Scintilační detektor sekundárních elektronů pro ESEM." Doctoral thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2016. http://www.nusl.cz/ntk/nusl-234652.

Full text
Abstract:
The thesis deals with the scintillation secondary electron detector for environmental scanning electron microscope, its design and construction. The starting point was numerical simulation of electrostatic fields and electron trajectories in the electrode system of the detector and simulation of pressure distribution and flow of gases in different parts of the detector. On the basis of modeling and simulation, construction changes of the detector were gradually implemented. Detection efficiency of each version of the detector was determined by the method described in the work. This method enables to evaluate signal level from the captured images of the specimen, quality of images was stated from signal to noise ratio. The thesis describes the whole process of the detector improvement from initial state, when the detector operated with lower efficiency in the pressure range from 300 to 900 Pa, to final version that enables usage of the detector in the range from vacuum up to 1000 Pa of water vapors in the specimen chamber of the microscope.
APA, Harvard, Vancouver, ISO, and other styles
3

Čudek, Pavel. "Scintilační detektor sekundárních elektronů pro ESEM." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2008. http://www.nusl.cz/ntk/nusl-217739.

Full text
Abstract:
The thesis deals with modifying and biulding of scintilation detector of secondary electrons for environmental scanning electron microscopy. It describes dilemma of environmental scanning electron microscopy, types of detectors and secondary electrons detection. The experimental part of this thesis focuses on the design and construction of new scintillation detector on the basis of simulations secondary electrons trajectories. Identifying the parameters, pressure dependencies and optimizations of electrode system of the detector realized.
APA, Harvard, Vancouver, ISO, and other styles
4

Račanský, David. "Scintilační detektor sekundárních elektronů pro VP SEM." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2011. http://www.nusl.cz/ntk/nusl-219370.

Full text
Abstract:
First part of this thesis is a theoretical essay which deals with the basics of the variable pressure scanning electron microscope, includes detection of secondary electrons with a view to a scintillation detector. The first applied part of the thesis is focused on prediction, measuring and setting-up optional working parley in vacuum electrodes scintillation detector system, with a stress small diameter hole in screenings C1 and C2. Second applied part was verify a change of working distance between sample and detector in consequence to optional solution for another work.
APA, Harvard, Vancouver, ISO, and other styles
5

Odehnal, Adam. "Scintilační detektor sekundárních elektronů pro environmentální rastrovací elektronový mikroskop." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2016. http://www.nusl.cz/ntk/nusl-242063.

Full text
Abstract:
Thesis deals with theoretical knowledge about scanning electron microscopy and environmental scanning electron microscopy. It describes principle of operation, signals generated by interaction between primary electron beam and specimen and means of detection of secondary electron signal in environmental conditions using scintillation detector. Furthermore, thesis focuses on optimization of detection od secondary electrons by adjusting electrode system of scintillation detector. Computer program Simion is used for modelling signal electron trajectories for proper adjustments. Simulation were starting-point for adjusting the design of the detector. Detection efficiency of adjusted detector was determined by evaluating signal magnitude from captured images, secondary electron detection capability from voltage contrast and quality of the captured images from signal/noise ratio.
APA, Harvard, Vancouver, ISO, and other styles
6

Kozák, Josef. "Scintilační detektor sekundárních elektronů s řízeným prouděním plynů pro EREM." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2009. http://www.nusl.cz/ntk/nusl-217926.

Full text
Abstract:
This master’s thesis deals with a design and optimization of an experimental scintillation secondary electron detector for the environmental scanning electron microscope and with a description of a detector operation principle. The experiment is founded on simulations of a gas flow in detector inner sections and on simulations of secondary electron trajectories in electrostatic fields of the detector. On the basis of the simulations, new solutions of the detector designs are proposed. For these designs, same simulations as previous are performed and designs that seem to be feasible for the secondary electron detection in environmental scanning electron microscope are selected.
APA, Harvard, Vancouver, ISO, and other styles
7

Poruban, Milan. "Analýza proudění plynů při čerpání vakua pro nově navržený scintilační detektor." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2014. http://www.nusl.cz/ntk/nusl-220571.

Full text
Abstract:
The aim of this thesis is to study the issue of eniveromental scanning electron microscopy and pumping gas to create vacuum in the newly designed scintillation detector. Further, creating a model of recently proposed scintillation detector and simulating and analyzing pumping gas in differentially pumped chamber of detector. The theoretical part deals with electron microscopy, electron sources, electron optics and secondary electrons detectors. It is also presented which signals are generated by the electron beam on the surface of a solid. Further fluid flow issues and equations describing the flow in the solved chamber are dismantled. Furthermore, the impact of gaseous environment on the trajectory of primary electrons, because there are collisions of primary beam with atoms and molecules of gas. The following section discusses creating, quality and importance of the network in mathematical modelling. A method of a final volume used to calculate the differential equations describing the flow of gas at the premises of the detector is described . The practical part consists in creating a model of scintillation detector and analyzing the gas flow in drawing a vacuum in the newly designed scintillation detector. At the end the simulation results of gas flow are compared for different variants of apertures and various pressures on the neck of a scintillation detector designed for optimum performance of the detector. The outcome of this thesis is model of newly designed scintillation detector with optimized shapes of apertures according to functional requirements.
APA, Harvard, Vancouver, ISO, and other styles
8

Flídr, Karel. "Vliv tvaru sacích kanálů na čerpání u scintilačního detektoru." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2015. http://www.nusl.cz/ntk/nusl-221082.

Full text
Abstract:
The thesis is concerned with the design of the shape of suction canals used for pumping in the scintillation detector. The goal is to perform analysis of the model of the detector according to the current conception and then perform an optimalisation of the suction canals as per demands to their function. In the beginning of the thesis the history of the microscope and electron microscopy is described. The next chapter is focused on a more detailed description of ESEM. The following charter is dedicated to describing the scintillation detector.The thesis recounts the kinds of liquid flow. In conclusion the programs SolidWorks and Ansys Fleunt are described. Next part of this thesis describes in detail parameters‘ settings of simulation calculation. Following chapter introduces designed changes of suction channels shape and its results are shown and described.
APA, Harvard, Vancouver, ISO, and other styles
9

Přichystal, Vít. "Návrh scintilačního detektoru s jednou clonkou pro enviromentální elektronový rastrovací mikroskop." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2014. http://www.nusl.cz/ntk/nusl-220570.

Full text
Abstract:
The thesis is focused on the design of a scintillation detector with one screen for environmental scanning electron microscope. At the beginning of the work is an introduction to microscopy. Further work is focused on the description of ESEM microscope and a scintillation detector. The following chapter is devoted to the dynamics of flow. They list the types of flow and mathematical description of equations. The next chapter is about using the software and the way of solution of flow. In the following chapter describes a proposal of the diaphragm and extraction method of the detector area. They are described some of type aperture. The last chapter is the conclusion, where the work is summarized.
APA, Harvard, Vancouver, ISO, and other styles
10

Buchta, Michal. "Metoda napěťového kontrastu v ESEM." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2008. http://www.nusl.cz/ntk/nusl-217627.

Full text
Abstract:
This graduation thesis deals with the problem of voltage contrast in ESEM. The purpose of this work was to verify influence of used detectors in the dependence on conditions in specimen chamber on the size of voltage contrast. With the conditions in specimen chamber we understand pressure and working conditions of signal detection. We used power transistor as specimen.
APA, Harvard, Vancouver, ISO, and other styles
11

Hubáček, Jiří. "Srovnání podmínek proudění plynu v detektoru při užití clonky a síťky." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2010. http://www.nusl.cz/ntk/nusl-218759.

Full text
Abstract:
The first part of the thesis deals with electron microscopy and physical model fluid flow. In the next part, a three-dimensional model is created in programme SolidWorks. It is the model of scintilating detector with aperture or screen with three hundred little apertures. These models are submitted to analysis focusing on investigation of the gas flow at different pressure in chamber of specimen ESEM using Cosmos FloWorks system. The results of the analysis of both apertures variants are compared with the request to minimize the pressure in the trajectory of the secondary electrons as well as in the chamber of specimen.
APA, Harvard, Vancouver, ISO, and other styles
12

Truhlář, Michal. "Vyhodnocení proudění plynu ve scintilačním detektoru při různých profilech a rozměrech otvorů v clonkách tvaru síťky." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2011. http://www.nusl.cz/ntk/nusl-219194.

Full text
Abstract:
This work deals with the flow of gas in the scintillation detector. Thesis describes the function of an electron microscope, the composition, distribution and development of microscopes from the earliest to modern. The work also includes familiarization with SolidWorks 3D modeling in which is the electron microscope modeled and Cosmos FloWorks in which they are carried out simulations of gas flow. The paper is focused on the flow of gas in various shapes of the screen and various pressures in chamber of specimen. The results of the analysis of both apertures variants are compared with the request to minimize the pressures in the trajectory of the secondary electrons of well as in the chamber of specimen.
APA, Harvard, Vancouver, ISO, and other styles
13

Koudela, Oldřich. "Kontrast v obraze získaném pomocí scintilačního detektoru sekundárních elektronů ve VP SEM." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2011. http://www.nusl.cz/ntk/nusl-219044.

Full text
Abstract:
First part of this thesis is a theoretical essay which deals with the basics of scanning electron microscopy, with structure and function of a scanning electron microscope, its’ special case of an various pressure scanning electron microscope, electron interaction with surrounding environment and with a scintillation detector. The applied part of the thesis is focused on evaluation of material contrast on Cu-W specimen. Material contrast is evaluated for different pressures of water vapors in the microscope specimen chamber and for different detection conditions.
APA, Harvard, Vancouver, ISO, and other styles
14

Kryll, Josef. "Analýza vlivu rozměrů čerpacích kanálů při konstrukci nové verze scintilačního detektoru." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2016. http://www.nusl.cz/ntk/nusl-254465.

Full text
Abstract:
The aim of this thesis is to study the issue of eniveromental scanning electron microscopy and pumping gas to create a vacuum in the newly designed scintillation detector. Further, creating a model of recently proposed scintillation detector and simulating and analyzing pumping gas in differentially pumped chamber of detector and the results compare with the previous model. The theoretical part deals with electron microscopy, electron sources, electron optics and secondary electrons detectors. It is also presented which signals are generated by the electron beam on the surface of a solid. Further fluid flow issues and equations describing the flow in the solved chamber are dismantled. Furthermore, the impact of gaseous environment on the trajectory of primary electrons, because there are collisions of primary beam with atoms and molecules of gas. The following section discusses creating, quality and importance of the network in mathematical modelling. A method of a final volume used to calculate the differential equations describing the flow of gas at the premises of the microscope is described . The practical part consists in creating a model of scintillation detector and analyzing the gas flow in drawing a vacuum in the newly designed scintillation detector. Furthermore, the simulation results are compared with the results of simulations on the older type of scintillation detector. The output of this thesis is model of recently proposed scintillation detector with visualized simulation results.
APA, Harvard, Vancouver, ISO, and other styles
15

Tihlaříková, Eva. "Optimalizace scintilačního detektoru pro detekci nízkoenegiových signálních elektronů v elektronové mikroskopii." Doctoral thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2017. http://www.nusl.cz/ntk/nusl-364601.

Full text
Abstract:
The dissertation thesis deals with optimization of the scintillation detector for efficient detection of low energy signal electrons in a specimen chamber of a scanning electron microscope. The solution was based on the study of signal electron energy loss mechanisms during their interaction with a conductive layer and a scintillator that can be studied using simulations based on the stochastics Monte Carlo methods. Based on test simulations and their comparison with experimental data, the ideal Monte Carlo software was chosen and used for the study of signal electron energy losses during their transport through the conductive layer as well as following interaction with scintillator, in dependency on the signal electron energy. Simulation results allowed to define criteria for the optimization of the conductive layer. According to these parameters, the optimized layers were deposited on the surface of different scintillators and experimentally tested in the scintillation detector of the scanning electron microscope. Experimental measurements allowed to verify accomplished simulations and provide new information about impact of materials and thicknesses of conductive layers in combination with materials of scintillators and light guides. The increase of the detection efficiency of the scintillation detector equipped with optimised conductive layers and its capability to detect low energy signal electrons were experimentally proved.
APA, Harvard, Vancouver, ISO, and other styles
16

Jabůrek, Ladislav. "Metoda napěťového kontrastu při detekci sekundárních elektronů scintilačním detektorem ve VP SEM." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2011. http://www.nusl.cz/ntk/nusl-219045.

Full text
Abstract:
This thesis deals with scanning electron microscope working at higher pressure in the specimen chamber. The main goal was to study the voltage contrast on the PN junction of the transistor under suitable working conditions for using environmental scanning microscope. The observation of sample was enabled by a scintillation detector designed for observation of high pressure.
APA, Harvard, Vancouver, ISO, and other styles
17

Novotný, Marek. "Vyhodnocení vlivu tvaru otvorů clonek na výsledný tlak na dráze sekundárních elektronů v detektoru pomocí systému CAE." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2011. http://www.nusl.cz/ntk/nusl-219193.

Full text
Abstract:
This diploma thesis deals with electron microscopy. Examined equipment is environmental scanning electron microscope (ESEM), namely scintillation a detector of the microscope. There is solved the influence of the profile of holes in diaphragms to the resulting pressure and gas flow on the path of secondary electrons at the detector. Introductory part of thesis informs about microscopy in general, with concentration on electron microscopy; especially on scanning microscope, because research is taken just on the environmental scanning electron microscope. Another part informs about both general principles of dynamics of gases and with finite volume method. Another part deals with concrete used software and with setting of individual parameters for calculation. At the beginning of calculation are used five basic profiles of holes in diaphragms for pressure 1000 Pa in the chamber of the sample. For modelling individual shapes is used 3D parametric modeller SolidWorks. Analysis of circulation of secondary electrons through detector is made by using Cosmos FloWorks module. The most suitable type of diaphragms is chosen from measured models. Another part of diploma thesis deals with measuring of chosen types of diaphragms for more pressures in the chamber of the sample; the pressure is 200, 400, 600, 800 and 1000 Pa. The outcomes of this research are both models of pressure and speed of circulation inside the detector and graphically processed values by using different diaphragms, respectively one type of a diaphragm in different pressures. Production drawings of each diaphragm, together with calculated models, are enclosed.
APA, Harvard, Vancouver, ISO, and other styles
18

Vykydal, Jan. "Digitální zpracování signálu pomocí programovatelných hradlových polí." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2020. http://www.nusl.cz/ntk/nusl-433462.

Full text
Abstract:
This thesis deals with the design, implementation and testing of an equipment that performs spectral analysis of a gamma radiation, based on the evaluation of pulses from a scintillation detector. The pulzes are pre-amplified and digitized, and their further processing takes place numerically in an FPGA, which allows a simple modification of the function of the developed device. After an introduction to the issue of gamma radiation spectroscopy with a focus on its detection, the thesis is devoted to the development of a multichannel analyzer hardware, whose individual parts are further described later. Next, the development of a digital signal processing system in the FPGA is described. Followed by an analysis of a microcontroller firmware, and a text protocol for the controlling of the device. Finally, the results of the work are discussed, with a focus on the test measurement of gamma radiation.
APA, Harvard, Vancouver, ISO, and other styles
19

Čermák, Peter. "Vyhodnocení vlivu výkonu vývěv na proudění plynu ve scintilačním detektoru s ohledem na funkčnost." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2011. http://www.nusl.cz/ntk/nusl-219067.

Full text
Abstract:
The work is devoted to problems of electron microscopy, focusing on the scintillation detector, which is located in chamber separating the field from different pressures. Using of the CAD and CAE was created 3D model of the detector, which took place on calculations focused to influence of the performance of different types of air pumps at gas flow between the chambers. The results of individual variants are compared in graphic form and evaluated.
APA, Harvard, Vancouver, ISO, and other styles
20

Skladaný, Roman. "Návrh detektoru sekundárních elektronů pro ultravakuový elektronový mikroskop." Master's thesis, Vysoké učení technické v Brně. Fakulta strojního inženýrství, 2019. http://www.nusl.cz/ntk/nusl-402574.

Full text
Abstract:
In this master’s thesis, a mechanical design of an in-column secondary electrons (SE) detector is presented. It is an ultravacuum compatible fibre-scintillation detector designed for use in an ultrahigh vacuum scanning electron microscope (UHV SEM). The designed in-column SE detector was manufactured and tested upon overcoming R&D challenges. The first section of this thesis deals with theoretical basis needed for understanding of functional principles of UHV SEM system and means of SE’s detection. In the second section, mechanical design of the in-column SE detector is described. The last section describes functionality of the designed detector. Effectiveness of light shielding of the detector was tested and the detective quantum efficiency was measured. Finally, images created by the designed in-column detector and an in-chamber SE detector were evaluated and compared.
APA, Harvard, Vancouver, ISO, and other styles
21

Lázna, Tomáš. "Autonomní robotické měření záření gama." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2017. http://www.nusl.cz/ntk/nusl-316267.

Full text
Abstract:
Tato práce se zaměřuje na autonomní lokalizaci radiologických zdrojů v definované oblasti zájmu. Jejím cílem je vyvinout lokalizační strategie a platformu, na které je bude možné vyzkoušet. Platforma je sestavena z průzkumného robotu Orpheus-X3, scintilačních detektorů a přesného GNSS přijímače. Algoritmus pro vytváření mapy distribuce radiačního pole je rozšířen. Jsou představeny nové metody založené na směrové citlivosti navrhovaného detekčního systému. Počáteční průzkum oblasti zájmu je uskutečněn pomocí kružnicových trajektorií. Všechny algoritmy byly otestována jak simulacemi, tak reálnými experimenty. Dosažená přesnosti lokalizace je v řádu desítek centimetrů. Časová efektivita je použitím nových algoritmů zvýšena přibližně dvakrát až pětkrát. Jedním z~přínosů práce je vývoj modulárního systému, který může být přesunut a uzpůsoben na jiné platformy. Výhodou použitého systému je vysoký stupeň autonomie a bezpečnost pro lidského operátora.
APA, Harvard, Vancouver, ISO, and other styles
22

PFEIFEROVÁ, Vendula. "Význam expresních havarijních metodik pro případ radiačních mimořádných situací." Master's thesis, 2008. http://www.nusl.cz/ntk/nusl-49806.

Full text
APA, Harvard, Vancouver, ISO, and other styles
23

Fajt, Lukáš. "Prototyp detektoru reaktorových antineutrin." Master's thesis, 2015. http://www.nusl.cz/ntk/nusl-350816.

Full text
Abstract:
Title: Prototype of detector for detection of reactor's antineutrinos Author: Lukáš Fajt Department: Institute of Particle and Nuclear Physics Supervisor: Doc. Ing. Ivan Štekl, CSc., IEAP, CTU in Prague Abstract: This master thesis is related to the development of the complex detector of reac- tor's antineutrinos, so called S3 , which is based on the polystyrene scintillation detectors. The detector S3 (dimensions 40 x 40 x 40 cm3 ) will be located in the close vicinity of a nuclear reactor (5-12 m) and its purpose will be to measure reactor's power, isotopic composition of the nuclear fuel and moreover verification of the sterile neutrino hypothesis by detecting reactor's antineutrinos via the Inverse Beta Decay (IBD) interaction. Within the thesis, the first prototype of the antineutrino detector was constructed. It is composed of 18 scintillation plates (40 x 20 x 1 cm3 ) and corresponding electronics. With this prototype the first test with cosmic muons were performed. Within the thesis, the energy reso- lution of the scintillation plates was significantly improved by the optimization of their chemical composition and selection of the optimal refractive material. The proper energy resolution is very important for the detector functionality. In addition, a new methods for the production of coating layer...
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography