Academic literature on the topic 'Sensores de metales pesados'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Sensores de metales pesados.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Journal articles on the topic "Sensores de metales pesados"
Torrente Trujillo, Armando, Liceth Viviana Calderón Manchola, and Edna Milena Joven Santofimio. "METALES EN SUELOS PRODUCTORES DE ARROZ DEL DISTRITO JUNCAL, HUILA – COLOMBIA." Suelos Ecuatoriales 50, no. 1y2 (December 12, 2020): 1–12. http://dx.doi.org/10.47864/se(50)2020p1-12_121.
Full textAlcántara-Malca, Daniel Adolfo, and Doris Esenarro-Vargas. "MÉTODO DE REMEDIACIÓN DE BAJO COSTO PARA DISMINUIR LA CONCENTRACIÓN DE METALES PESADOS EN AGUAS CONTAMINADAS POR LA ACTIVIDAD MINERA." Biotempo 15, no. 2 (March 26, 2019): 149–56. http://dx.doi.org/10.31381/biotempo.v15i2.2054.
Full textPadilla Sobrados, José A., Eleuterio Ramírez Apolinario, Rosario Barra Zegarra, and Juan F. Barreto Rodriguez. "Niveles de concentración de metales pesadios en especies vegetales emergentes en el pasivo minero ambiental de Ticapampa, Catac, Huaraz, Perú." APORTE SANTIAGUINO 2, no. 1 (July 19, 2009): 21. http://dx.doi.org/10.32911/as.2009.v2.n1.372.
Full textRamírez Méndez, Eduardo, Jesús Valdés-Reyna, Antonio Juárez-Maldonado, Nadia Valentina Martínez-Villegas, and Lorenzo Alejandro López-Barbosa. "Biomonitoreo de metales pesados en vegetación arbórea en la ciudad de Saltillo." Revista Mexicana de Ciencias Agrícolas, no. 26 (July 8, 2021): 191–99. http://dx.doi.org/10.29312/remexca.v0i26.2949.
Full textPabón Guerrero, Santiago Eduardo, Ricardo Benítez Benítez, Rodrigo Andrés Sarria Villa, and José Antonio Gallo Corredor. "Contaminación del agua por metales pesados, métodos de análisis y tecnologías de remoción. Una revisión." Entre Ciencia e Ingeniería 14, no. 27 (July 19, 2020): 9–18. http://dx.doi.org/10.31908/19098367.1734.
Full textPineda, Mayra Eleonora Beltrán, and Alida Marcela Gómez Rodríguez. "Metales pesados (Cd, Cr y Hg): su impacto en el ambiente y posibles estrategias biotecnológicas para su remediación." I3+ 2, no. 2 (August 31, 2015): 82. http://dx.doi.org/10.24267/23462329.113.
Full textChui, Heber N., Bernardo Roque, Edilberto Huaquisto, Danitza L. Sardón, German Belizario, and Alfredo P. Calatayud. "Metales pesados en truchas arcoíris (Oncorhynchus mykiss) de crianza intensiva de la zona noroeste del lago Titicaca." Revista de Investigaciones Veterinarias del Perú 32, no. 3 (June 23, 2021): e20398. http://dx.doi.org/10.15381/rivep.v32i3.20398.
Full textMoreno-Rivas, Silvia Carolina, and Gabriela Ramos-Clamont Montfort. "Descontaminación de arsénico, cadmio y plomo en agua por biosorción con Saccharomyces cerevisiae." TIP Revista Especializada en Ciencias Químico-Biológicas 21 (October 10, 2018): 51. http://dx.doi.org/10.22201/fesz.23958723e.2018.0.155.
Full textCaviedes Rubio, Diego Ivan, Ramiro Adolfo Muñoz Calderón, Alexandra Perdomo Gualtero, Daniel Rodríguez Acosta, and Ivan Javier Sandoval Rojas. "Tratamientos para la Remoción de Metales Pesados Comúnmente Presentes en Aguas Residuales Industriales. Una Revisión." Ingeniería y Región 13, no. 1 (September 9, 2015): 73. http://dx.doi.org/10.25054/22161325.710.
Full textContreras Pérez, José Bernardino, Carmen Leticia Mendoza Gómez, and Arismendis Gómez. "Determinación de metales pesados en aguas y sedimentos del Río Haina." Ciencia y Sociedad 29, no. 1 (March 1, 2004): 38–71. http://dx.doi.org/10.22206/cys.2004.v29i1.pp38-71.
Full textDissertations / Theses on the topic "Sensores de metales pesados"
Pinheiro, Silvia Cristina Lopes. "Determinação simultânea de metais pesados em águas empregando sensores fluorimétricos e calibração multivariada." [s.n.], 2010. http://repositorio.unicamp.br/jspui/handle/REPOSIP/250561.
Full textTese (doutorado) - Universidade Estadual de Campinas, Instituto de Química
Made available in DSpace on 2018-08-17T08:47:53Z (GMT). No. of bitstreams: 1 Pinheiro_SilviaCristinaLopes_D.pdf: 3031586 bytes, checksum: d04087a8b894575a32142d906b54d76b (MD5) Previous issue date: 2010
Resumo: O objetivo deste trabalho foi desenvolver sensores fluorimétricos empregando os reagentes luminescentes ZOX (2-piridin-2-il-benzooxazol), [Ru(s2d)2(bim)] (complexo de Ru(II), onde s2d: 1,10-fenantrolina-4,7-di-il) bis(benzenossulfonato e bim: 2,2¿-biimidazol) bpySOH (4-[2-(4¿-metil-[2,2¿] bipiridil-4-il)-vinil]-fenol) e bpySOMA (2-metileno ácido butírico-4-[2-(4¿-metil-[2,2¿] bipiridil-4-il)-vinil]-fenil éster) para a determinação simultânea de metais pesados em águas. Os fluoróforos ZOX e [Ru(s2d)2(bim)] não forneceram resultados satisfatórios uma vez que sofreram lixiviação das matrizes (sol-gel) nas quais estavam imobilizados. Por outro lado, o reagente bpySOH e seu derivado bpySOMA forneceram bons resultados na caracterização em solução assim como na forma imobilizada. Estudos espectrofotométricos em solução com o bpySOH demonstraram estequiometrias de complexação ligante:metal de 1:1 para Cd(II), Ni(II) e Zn(II) e de 2:1 para Cu(II) e Hg(II). As constantes de estabilidade calculadas através de dados espectrofotométricos indicaram que os complexos de Cu(II), Hg(II) e Zn(II) são os mais estáveis. Estudos mostraram que Cu(II), Ni(II) e Zn(II) desativam a emissão do ligante, enquanto Hg(II) e Cd(II) incrementam essa propriedade. Experimentos de tempo de vida demonstraram um mecanismo de supressão estática da fluorescência para todos os complexos. Como estratégia de imobilização do ligante, avaliou-se uma matriz sol-gel (a partir do precursor TMOS). Imobilizado, o ligante mostrou resposta reversível para Cu(II), Hg(II) e Zn(II). O intervalo de resposta obtido para os íons metálicos foi de 2,50¿30,0 mmol L. A determinação simultânea em misturas contendo 2 ou 3 íons foi realizada utilizando Regressão por Mínimos Quadrados Parciais. Os modelos de calibração multivariada apresentaram resultados de previsão satisfatórios com valores de RMSEP inferiores a 3,00 mmol L. O derivado bpySOMA, por sua vez, apresentou comportamento semelhante em termos de valores de estequiometrias de complexação e constantes de estabilidade. Para imobilizá-lo, empregou-se um MIP seletivo para Cu(II). Estudos indicaram a seletividade para este metal frente a Cd(II), Hg(II), Ni(II), Pb(II) e Zn(II). Uma faixa de resposta foi obtida no intervalo de 0,1¿6,0 mmol L. O sensor foi aplicado à determinação de Cu(II) em águas de torneira fortificadas com o metal. Os resultados obtidos, quando comparados com um método de referência (FAAS) indicaram a aplicabilidade do sensor e que o mesmo apresenta potencialidade para trabalhos futuros.
Abstract: This thesis is aimed at developing fluorimetric sensors employing luminescent reagents ZOX (2-pyridin-2-yl-benzooxazole), [Ru(s2d)2(bim)](Ru complex, where s2d: 1,10-phenanthroline-4,7-diyl)bis(benzenesulfonate) and bim: 2,2¿-biimidazole), bpySOH (4-[2-(4¿-methyl-[2,2¿]bipyridinil-4-yl)-vinyl]-phenol) and bpySOMA (2-methylene-butyric acid 4-[2-4¿-methyl-[2,2¿]bipyridinyl-4-yl)-vinyl]-phenyl ester) for the simultaneous determination of heavy metals in waters. The fluorophores ZOX and [Ru(s2d)2(bim)] did not provide satisfactory results, being leached out from the matrix in which they were immobilized. On the other hand, bpySOH and its derivative bpySOMA provided good results in solution as well as after immobilization. Spectrophotometric studies of bpySOH in solution showed stoichiometries ligand:metal of 1:1 for Cd(II), Ni(II) and Zn(II) while 2:1 ratio was obtained for Cu(II) and Hg(II). Stability constants calculated from spectrophotometric data indicated that Cu(II), Ni(II) and Zn(II) complexes are the most stable. In addition, it was observed that Cu(II), Ni(II) and Zn(II) quench the fluorescence of the ligand, while Hg(II) and Cd(II) enhance this property. Lifetime studies demonstrated a static mechanism of quenching of fluorescence for all complexes. The ligand was immobilized in a sol-gel matrix (obtained from TMOS precursor), which presented reversible response for Cu(II), Hg(II) and Zn(II). The response range for the metal ions was 2.50¿30.0 mmol L. Simultaneous determinations of mixtures containing 2 or 3 ions were performed using the Partial Least Square method. Multivariate calibration models showed satisfactory prediction results, with RMSEP values lower than 3.00 mmol L. The derivative ligand bpySOMA showed similar results in terms of complexation stoichiometries and stability constant values. It was immobilized as a molecularly imprinted polymer selective to Cu(II), confirmed by the response of the non-imprinted polymer for Cd(II), Hg(II), Ni(II), Pb(II) and Zn(II) ions. A response range of 0.1¿6.0 mmol Lwas obtained. The sensor was applied to the determination of Cu(II) in tap water and the results agreed with those obtained by Flame Atomic Absorption Spectrometry.
Doutorado
Quimica Analitica
Doutor em Ciências
Niu, Pengfei. "Carbon Xerogel nanocomposite materials for electrochemical devices: application to heavy metal detection." Doctoral thesis, Universitat Autònoma de Barcelona, 2015. http://hdl.handle.net/10803/309289.
Full textEn esta Tesis se describe la fabricación de electrodos nanocompuestos de carbono poroso en forma de capa delgada y capa gruesa y su aplicación al análisis de metales pesados en aguas. Estos nanocompuestos de carbono se prepararon a partir de la pirolisis de materiales obtenidos por química sol-gel, concretamente de geles de resorcinol-formaldehído y de resorcinol-formaldehído con sílice, que contenían precursores de bismuto. Los geles pirolizados presentan una estructura de carbono poroso con porosidad abierta que contiene nanopartículas de bismuto bien distribuidas. Estos materiales se molieron hasta obtener granulometrías adecuadas para hacer electrodos de pasta de carbono para estudios de laboratorio y para hacer electrodos serigrafiados de capa gruesa de tipo comercial. Estos electrodos presentan una respuesta muy buena en el análisis de metales pesados en aguas, obteniéndose límites de detección de Pb(II), Cd(II) y Ni(II) que están muy por debajo de las concentraciones máximas contempladas por las normativas de agua para el consumo de la Unión Europea y Estados Unidos (US-EPA). Se llevaron a cabo análisis de Pb(II), Cd(II), Ni(II), Zn(II) y Cu(II) en aguas reales de diferente origen y complejidad y en la mayoría de casos se obtuvieron resultados en acuerdo con las medidas realizadas por espectroscopia de masas. Asimismo, se estudiaron las limitaciones de los sensores desarrollados y las interferencias entre los analitos. En relación a los electrodos en capa delgada, por spin-coating se depositaron capas uniformes y continuas de soles de resorcinol-formaldehído que contenían un precursor de SiO2 sobre obleas de SiO2/Si de 4 pulgadas. Se comprobó que después de la pirolisis la adhesión de las capas de carbono sobre la capa de SiO2/Si mejoraba mucho incorporando el precursor de SiO2en el sol. Los electrodos de carbono/sílice en capa delgada se fabricaron tanto por fotolitografía como por soft-lithography. Estos electrodos no presentaron respuesta alguna en voltamperometría cíclica en soluciones de ferri/ferrocianuro pero sí que lo hicieron en el caso de una sonda redox de ferroceno. En el caso de las capas delgadas, la incorporación de nanopartículas de Bi mediante un procedimiento análogo al seguido para la síntesis de los geles macroscópicos presentaba problemas debido a la evaporación de Bi durante la pirolisis. Sin embargo, estos electrodos se pudieron utilizar satisfactoriamente para el análisis de metales pesados haciendo una co-deposición electroquímica de Bi con los metales pesados analizados.
This Thesis describes the fabrication of both thick-film and thin-film electrodes with porous carbon nanocomposite materials and the application of these electrodes in the electrochemical analysis of heavy metals in aqueous solutions. These carbon composites were obtained from the pyrolysis of materials prepared by sol-gel chemistry approach, namely resorcinol-formaldehyde and resorcinol-formaldehyde /silica gels containing bismuth precursors. Bulk bismuth nanoparticle-carbon xerogel nanocomposite materials consist of an open porous structure of carbon with well distributed bismuth nanoparticles. These materials were ball-milled into powders of suitable size to produce conventional paste electrodes to be characterized in the lab and commercial-like screen printed thick-film electrodes. These electrodes display a superior performance in the sensitive stripping voltammetric detection of heavy metals in waters. The limit of detections for Pb(II), Cd(II) and Ni(II) obtained using these electrodes are well below the threshold concentrations established for drinking water quality by the EU and the US-EPA. The analysis of Pb(II), Cd(II), Ni(II), Zn(II) and Cu(II) have been performed in real waters of different origin and complexity, showing results in agreement with the standard mass spectroscopy method. The limitations of the developed electrodes and the interferences between different analytes were also investigated. In the case of thin film electrodes, large scale uniform and continuous carbon/silica films were deposited on 4-inch SiO2/Si wafers by spin-coating resorcinol-formaldehyde sols containing a SiO2 precursor. The interfacial adhesion between carbon films and SiO2/Si substrates is significantly enhanced by the addition of SiO2. Carbon/silica thin-film electrodes were fabricated by both photolithography and soft-lithography processes. These electrodes did not provide any cyclic voltamperometric signals in inner-sphere ferri-/ferrocyanide solutions but were successfully characterized in solutions containing outer-sphere ferrocene redox probe. The incorporation of bismuth nanoparticles into carbon/silica films during their sol-gel deposition stage is challenging due to the loss of bismuth by evaporation during pyrolysis step. Nevertheless, these electrodes were successfully applied for the detection of heavy metals by co-deposition of bismuth and heavy metals.
Silva, Martin Kássio Leme da. "Desenvolvimento de Sensores Eletroquímicos para a Detecção de Metais Pesados." Botucatu, 2019. http://hdl.handle.net/11449/191123.
Full textResumo: Este trabalho apresenta, a caracterização e aplicação de um nanocompósito à base de óxido de grafeno reduzido (rGO) modificado com nanopartículas de antimônio (SbNPs) na análise simultânea e individual dos íons Cd2+, Pb2+, Cu2+ e Hg2+ em amostras de água de torneira. O nanocompósito rGO-SbNPs foi sintetizado por um método de redução química utilizando borohidreto de sódio como agente redutor. O trabalho investigou as propriedades eletrônicas do rGO com a combinação sinérgica de SbNPs. Os resultados mostraram que o eletrodo GC/rGO-SbNPs detectou seletivamente os metais pesados (HMs) com alta sensibilidade, considerando os valores máximos permitidos para consumo de água potável no Brasil. Sob condições otimizadas, o eletrodo proposto apresentou um ajuste significativo de correlação linear com as concentrações dos íons Cd2+, Pb2+, Cu2+ e Hg2+ variando de 0,1 a 4,5 µmol L-1. Os limites de detecção para determinação individual desses íons foram: 7,7 (Cd2+), 3,0 (Pb2+), 4,7 (Cu2+) e 9,6 (Hg2+) nmol L-1. Este trabalho revela a viabilidade do nanocompósito rGO-SbNPs na análise de HMs por voltametria de redissolução anódica de onda quadrada (SWASV), bem como, uma nova abordagem para análise in-situ destes metais.
Abstract: This work presents for the first time the characterization and application of a nanocomposite based on reduced graphene oxide (rGO) modified with antimonium nanoparticles (SbNPs) in the stripping analysis of Cd2+, Pb2+, Cu2+ and Hg2+ in drinking water samples. The nanocomposite was easy synthesized by a chemical reduction method using sodium borohydride as the reductant agent. The experiments investigated the remarkable rGO electronic properties with the synergetic combination of metallic SbNPs. The results showed that the GC/rGO-SbNPs electrode selective detected the heavy metal ions (HMs) with high sensitivity, regarding the standards of potable drinking water in Brazil. Under optimal conditions the proposed electrode showed good linear relationship with the concentration of Cd2+, Pb2+, Cu2+ and Hg2+ ranging from 0.1 to 4.5 µmol L-1 . The detection limits for individual determination of these ions were: 7,7 (Cd2+), 3,0 (Pb2+), 4,7 (Cu2+) and 9,6 (Hg2+) nmol L-1 .This work presents an analysis of the properties of the nanocomposite rGO-SbNPs in the analysis of HMs by square wave anodic voltammetry (SWASV), as well as a new approach for in situ analysis of these metals
Mestre
Cadevall, Riera Miquel. "Bismuth based (nano)materials and platforms for (bio)sensing." Doctoral thesis, Universitat Autònoma de Barcelona, 2014. http://hdl.handle.net/10803/285769.
Full textThe thesis is focused on the fabrication of new sensing and biosensing platforms for pollutants detection. Although bismuth-based micro and nanomaterials seem to be the appropriated materials to achieve this objective nevertheless new platforms including for example those based on paper are also proposed. In the first chapter the main objectives of this thesis are described in detail. The introduction part (chapter 2) of this thesis is dedicated to the revision of the recent reports / achievements on bismuth-based nanomaterials in different application fields that include medicine, photodegradation of organic pollutants, cosmetics, pigments and alloys. An important section of this part is focused on the description of the effect of bismuth-based materials in heavy metals and biosensing applications. Bismuth nanoparticles are found as an innovative material in heavy metals sensing and biosensing applications. A study on the effect of the modification of screen-printed electrodes with bismuth nanoparticles and its use for the heavy metal detection is shown (chapter 3). Different modifications of polyol based bismuth nanoparticles synthesis have been evaluated in aim to obtain the more efficient nanoparticles with interest in heavy metal sensing. In addition the results obtained for the detection of lead and cadmium is also shown in the same chapter. In the chapter 4 a new electrode modification strategy is presented. This new strategy is based on the use of magnetic core/shell bismuth nanoparticles. Taking advantages of the bismuth oxide presence onto the shell of these nanoparticles, heavy metal detection in different On-Off sensing platforms is shown. The modification of electrodes is clearly demonstrated by doing cycles with both modification and cleaning of the electrodes obtaining a kind of digital (On-Off) response of heavy metals. To solve sampling and sample pretreatment issues a heavy metal sensing platform that uses a paper-based lateral flow chip is also developed and described at chapter 5. Fabrication and the optimization of this new heavy metal sensor are shown; it takes advantage of the use of a filter paper substrate. This new platform is capable to detect lead and cadmium in different matrixes including mud. In the last chapter (chapter 6), the integration of bismuth nanoparticles into a phenol biosensing system is shown. It takes advantages of the use of tyrosinase enzyme which brings certain selectivity in phenolic compounds detection. Morphological and electrochemical characterizations of the developed biosensor also are shown in this chapter. The developed biosensor shows good performance in catechol detection. Finally in the chapter 7 the general conclusions and some future perspectives are given.
Díaz, Rengifo Juan Arturo. "Desarrollo de un sistema integral para monitorización in situ de metales pesados." Doctoral thesis, Universitat Politècnica de Catalunya, 2001. http://hdl.handle.net/10803/6976.
Full textComprende tres áreas disciplinarias:
En la primera área, la electroquímica, se desarrollan sensores químicos que a su vez se dividen en tres etapas: En la primera etapa, se estudia la fabricación de electrodos convencionales de cabezal reemplazable selectivos a los cationes de cobre(II), cadmio(II) y plomo(II). En la segunda etapa, el estudio de nuevos electrodos selectivos a los mismos cationes del estudio anterior en configuración plana basado en tecnología "thick film", adaptada a nuestras necesidades de fabricación mediante la técnica de moldeo ("casting"). Por último, en la tercera etapa, se estudia la fabricación de electrodos de referencia de configuración plana con la misma tecnología.
La segunda área es la informática, en la que se desarrolla un paquete de herramientas basado en "software" de LabVIEW versión 5.1, con el nombre de Instrumentación Virtual para el Control Potenciométrico de Sensores Químicos, (en inglés "VIPCCHES"). Este paquete está capacitado para el tratamiento de la información que contienen las señales analíticas procdentes de los sensores. Tiene tres funciones importantes. La primera función es la calibración de los electrodos por dos métodos: calibración externa continua y calibración externa discontinua, ambos en dos modos de operación, modo individual y modo "array" de electrodos.
Una segunda función del paquete VIPCCHES es la adquisición de datos en modo continuo de un electrodo o un array de electrodos, permitiendo al usuario programar las medidas necesarias en tiempos de adquisición variables. La tercera función operativa del programa, es la realización de análisis de muestras de metales para un electrodo o un "array" de electrodos. El valor de la señal adquirida es promediado y éste es confrontado con una curva de calibración del electrodo plano de manera automática, presentando los resultados de manera gráfica y numérica. Finalmente, los resultados pueden ser tratados mediante programas estándar tipo Excel.
En el área de la electrónica, se ha construido un dispositivo para procesar las señales que proceden de los electrodos planos de nombre "SPPAE" que permite la adecuación de las señales a la Tarjeta de Adquisición de Datos (TAD) en el ordenador. Está diseñado con filosofía de expansión, por medio de módulos de amplificación y filtrado (anti-aliasing) que se insertan en un Bus de alimentación.
La integración de estos tres sistemas (electrodos de configuración plana, el SPPAE y el VIPCCHES) forman parte del Sistema Integrado para Monitorización Ambiental que conocemos como SIMA estando dicho sistema capacitado para realizar análisis "in situ" de metales pesados.
In this work, a Integrated System for monitoring in situ of heavy metals was developed. Include three disciplinary areas, the electronic, the information technology and the electrochemical. The first step was development now chemical sensors selective to cationes using thick film technology. The second task was the development of one virtual instrument (VI), which is the essential part of the system, using the graphical programming language LabVIEW which is capable of performing measurements functions, including data acquisition, display, analysis in the time and frequency domains, data archiving and read to file. Finally its build a signals processor, for the now plane and miniaturised electrodes. The installations of these elements in a portable computer consist in the Integrated System.
Keywords: thick film, chemical sensors, integrated systems, virtual instrumentation, signals processor, in situ measurements, monitoring, heavy metals.
Vásquez, Villafana Glibver José. "Desarrollo de un sensor químico a base de nanopartículas de oro para la determinación de Hg2+ en muestras de agua utilizando dispersión Rayleigh de resonancia." Master's thesis, Pontificia Universidad Católica del Perú, 2016. http://tesis.pucp.edu.pe/repositorio/handle/123456789/7004.
Full textTesis
Güell, Martí Raquel. "Development of chemical separation processes for the treatment and monitoring of metallic cations and oxoanions in polluted waters." Doctoral thesis, Universitat de Girona, 2011. http://hdl.handle.net/10803/51663.
Full textLa contaminació química de les aigües naturals és un problema global amb repercussió a nivell mundial. Donada la rellevància que té aquesta problemàtica, en la present tesi s’han desenvolupat d’una banda tècniques de separació/preconcentració basades en diferents sistemes de membrana en què el mecanisme de transport proposat és un bescanvi aniònic per als oxoanions tòxics de crom(VI) i arsènic presents en matrius aquoses. Concretament, s’ha treballat amb membranes líquides suportades que contenien el portador comercial Aliquat 336, membranes d’inclusió polimèriques amb el mateix portador i membranes de bescanvi aniònic comercials. D’altra banda, s’ha treballat en el desenvolupament de diferents sensors químics per monitoritzar diversos metalls presents en matrius aquoses. Així, s’ha dissenyat un sistema de sensor òptic selectiu a Cr(VI) basat en membranes polimèriques utilitzant també el portador Aliquat 336 i s’ha desenvolupat un sistema de monitorització per plom, coure, cadmi i zinc basat en microelèctrodes serigrafiats modificats amb mercuri.
Yamasaki, Alzira. "Estudos de adsorção de metais com interesse ambiental utilizando sensores acústicos de cristais piezoelétricos de quartzo." Doctoral thesis, Universidade de Aveiro, 2005. http://hdl.handle.net/10773/3202.
Full textA descarga de efluentes industriais, deposições atmosféricas, esgotos dos centros urbanos e contaminação proveniente de explorações agrícolas têm contribuído muito para o aumento da carga de metais pesados nos ambientes aquáticos. É desejável que a quantificação desses metais se faça por técnicas baratas, fiáveis e simples de utilizar, de modo a torná-las mais aplicáveis e permitir difundir os seus resultados na sociedade. A Microbalança de Cristal de Quartzo, MCQ, é um dispositivo piezoelétrico que alia a sua elevada sensibilidade à simplicidade e demonstrou já capacidade para produzir resultados fiáveis em análises quantitativas. No entanto, a MCQ não possui sensibilidade necessária para detectar metais ao nível de traços, tornando-se necessário fazer uso da Microbalança Eletroquímica de Cristais de Quarzto (MECQ), a qual dá informações complementares importantes em relação às técnicas eletroquímicas usuais, tais como mudanças de massa à superfície do eletrodo ou mudanças na viscosidade e densidade da solução. A leitura da massa depositada no eletrodo do cristal de quartzo, por Voltametria de Redissolução Anódica, permitiu determinar a concentração de cobre, dissolvido e na matéria particulada, existente na Ria de Aveiro, com limite de detecção de 1,46 μg L-1. A MECQ permitiu ainda estudar, sob uma nova perspectiva, os fenômenos de complexação. Essa possibilidade foi explorada mediante estudos da interação do chumbo com os ácidos húmicos. Estudos que envolveram processos de adsorção do cobre e do chumbo nos ambientes aquáticos foram também realizados com a MCQ. Porém, torna-se importante salientar que as concentrações dos metais em estudo estiveram na ordem dos mg L-1. Esses estudos foram concretizados recorrendo-se a modelos tão próximos quanto possíveis da natureza, colocando-se o cobre e o chumbo em contato com substâncias que simularam o material orgânico (ácidos húmicos) e os óxidos metálicos (Fe e Mn). Essa pesquisa se realizou revestindo-se os cristais de quartzo com substâncias que permitiram modelar esses componentes, existentes nos sistemas estuarinos. A superfície dos cristais revestidos foi estudada recorrendo-se à Difração de Raios X, a fim de se realizar a caracterização mineralógica dos produtos sintetizados que foram empregados para revestir o cristal piezoelétrico. Os ensaios biológicos, seguidos em tempo real, consistiram no desenvolvimento de uma metodologia para monitorar o crescimento de bactérias originárias da Ria de Aveiro, na presença de quantidades conhecidas de cobre, por meio dos cristais de quartzo. Com essa metodologia, foi possível determinar a quantidade a partir da qual o cobre se tornava tóxico e provocava a destruição das bactérias.
The discharge of industrial effluent, atmospheric depositions, sewers of the urban centers and contamination proceeding from agricultural explorations have been contributing to the increase of the heavy metal loading in aquatic environment. The availability of simple and inexpensive techniques to quantify those metals would allow the analysis to be made on a rotinary basis and their results to be widespreaded between the population. The Quartz Crystal Microbalance, QCM, is well known by its sensitivity and simplicity and was already shown to be able to produce reliable results in quantitative analysis. However, the QCM does not possess the necessary sensitivity to detect metals at trace level, becoming necessary to include an electrochemical preconcentration stage. The Electrochemical Quartz Crystal Microbalance, EQCM, gives important complementary information in relation to the usual electrochemical techniques, such as changes of mass onto the surface of the electrode and changes in viscosity and density of the solution. The reading of the mass deposited on the electrode of the quartz crystal, by Anodic Stripping Voltammetry, allowed to determine the copper concentration, dissolved and in the particulate matter, existing in Ria de Aveiro, with a detention limit of 1,46 μg L-1. The EQCM also allowed studying the complexation phenomena, under a new perspective. This possibility was explored by studying the interaction of lead with the humic acids. Adsorptions of copper and lead in aquatic environment have also been carried out with the QCM. However, it is important to point out that the concentration of the metals on these studies had been in the range of mg L-1. These studies had been done using models to mimic adsorption in the nature. Copper and lead were put in contact with substances that simulated the organic material (humic acids) and metallic oxides (Fe and Mn). This research was carried out coating the quartz crystals with the humic acids and metallic oxides. The surface of coated crystals was studied by XR diffraction, in order to characterize mineralogicaly the synthesized products that have been used to coat the piezoelectric crystal. The biological assays, followed in real time, used a methodology specially developed to monitor the growth of bacteria isolated from Ria de Aveiro. These studies were carried out both in the absence and in the presence of well-known amounts of copper, using quartz crystals. With this methodology, it was possible to determine the amount of copper beyond which toxicity was detected and provoked the destruction of the bacteria.
Cristóbal, Elescano David Edú. "Evaluación de las concentraciones de cadmio en las hojas de maíz en relación a su disponibilidad en suelos de diferente pH en el Valle del Mantaro." Bachelor's thesis, Universidad Continental, 2018. http://repositorio.continental.edu.pe/handle/continental/4439.
Full textSantos, Bonilla Karín Ángela. "Biosorción de metales pesados empleando lodos activados." Universidad Nacional de Ingeniería. Programa Cybertesis PERÚ, 2010. http://cybertesis.uni.edu.pe/uni/2010/santos_bk/html/index-frames.html.
Full textBooks on the topic "Sensores de metales pesados"
Introducción al estudio de la contaminación del suelo por metales pesados. Mérida, Yucatán, México: Ediciones de la Universidad Autónoma de Yucatán, 2000.
Find full textSilver, Mendieta Cardenas Richard, ed. Salinización y metales pesados: Evaluación ambiental de la mIna : "Kori Kollo" (EMIRSA) en el área de influencia con aplicación de la Teledetección - SIG. Oruro, Bolivia: CEPA, 2006.
Find full textDolores, Lucía, ed. La verdad sobre las enfermedades emergentes: Los peligros de los metales pesados : autismo, fatiga crónica, fibromialgia, espasmofilia, sensibilidad electromagnética, alergias, alzheimer, depresión, enfermedades autoinmunes, esclerosis múltiple /\cFrançoise Cambayrac ; [traducción, Dolores Lucía]. Barcelona: Ediciones Obelisco, 2013.
Find full textSalamanca, M. A. Heavy metal content and distribution in surface sediments from three areas of Chilean coast =: Contenido y distribución de metales pesados en sedimentos superficiales de tres áreas de la costa de Chile. Concepción: Universidad de Concepción, 1988.
Find full textIntoxicacion de animales por metales pesados - 1. edicion. Divulgacion Cientifica Veterinaria, 2019.
Find full textMetodología de análisis temporal para metales pesados en sedimentos viales - 1. edición. Universidad Distrital Francisco Jose de Caldas, 2015.
Find full textA, Manrique Fournier, and Spain. Ministerio de Agricultura, Pesca y Alimentación., eds. Niveles de metales pesados en los sedimentos actuales del Parque Nacional de Doñana. Madrid: Instituto Nacional de Investigaciones Agrarias, 1985.
Find full textBook chapters on the topic "Sensores de metales pesados"
Andreas Toba, Faustino, Aura Falco, Carlos Andrés Aranaga, and Guillermina Alonso. "Caracterización de bacterias aisladas en un reservorio de agua en venezuela. Una aproximación a la multirresistencia bacteriana en ambientes naturales." In La contaminación industrial de aguas: Una mirada microbiológica y molecular, 93–120. Editorial Universidad Santiago de Cali, 2018. http://dx.doi.org/10.35985/9789585522381.3.
Full textConference papers on the topic "Sensores de metales pesados"
Pacheco Menor, Maria Concepción, Juan Miguel Meneses Rodríguez, Raquel Maya Amado, and María Luisa Carmona Carmona. "Caracterización de cenizas de biomasa con metales pesados adsorbidos como adición en hormigones." In HAC2018 - V Congreso Iberoamericano de Hormigón Autocompactable y Hormigones Especiales. Valencia: Universitat Politècnica València, 2018. http://dx.doi.org/10.4995/hac2018.2018.5529.
Full textCruz Monterrosa, Rosy, and Adolfo Armando Rayas Amor. "Cuantificación de metales pesados en el cultivo de la fresa (fragariaxananassaduch. Var. festival) en Tenancingo y Villa Guerrero." In Conferencia Interdisciplinaria de Avances en Investigación. Lerma Estado de México, México: Universidad Autónoma Metropilitana, Unidad Lerma, 2018. http://dx.doi.org/10.24275/uam/lerma/repinst/ciai2018/000141/cruz.
Full textBolonio, David, María Jesús García, Iker García-Garizabal, Samantha Jiménez, Marcelo Ortega, and Washington Pincay. "Análisis espacial del riesgo para la salud por exposición a metales pesados en el campo minero Ponce Enríquez, Ecuador." In The 17th LACCEI International Multi-Conference for Engineering, Education, and Technology: “Industry, Innovation, and Infrastructure for Sustainable Cities and Communities”. Latin American and Caribbean Consortium of Engineering Institutions, 2019. http://dx.doi.org/10.18687/laccei2019.1.1.117.
Full textAsmat-Campos, David Angel, Karin Lizbeth Andrade-Zavaleta, Yessica Laurita Chacon-Laiza, Ana Cecilia Francisca Henriquez-Alegría, and Fiorella Arely Iparraguirre-Paredes. "Síntesis Ecológica De Nanopartículas De Feo Y Su Aplicación En La Remoción De Metales Pesados Presentes En Suelo Agrícola." In The 19th LACCEI International Multi-Conference for Engineering, Education, and Technology: “Prospective and trends in technology and skills for sustainable social development” “Leveraging emerging technologies to construct the future”. Latin American and Caribbean Consortium of Engineering Institutions, 2021. http://dx.doi.org/10.18687/laccei2021.1.1.19.
Full textYoan Martínez ROBAINA, Alexei, José Manuel Febles GONZÁLEZ, Nelson Moura Brasil do AMARAL SOBRINHO, and Mileisys Benitez ODIO. "CONCENTRACIONES Y DISPONIBILIDAD DE METALES PESADOS EN SUELOS DESTINADOS AL CULTIVO DEL TABACO LOCALIZADOS EN LA LLANURA SUR DE PINAR DEL RÍO-CUBA." In IV Simpósio ABC: Argentina-Brasil-Cuba. Seropédica, Rio de Janeiro: Even3, 2020. http://dx.doi.org/10.29327/ivsimposioabc.238141.
Full textAsmat-Campos, David Angel, Jhordi Ivan Bautista-Guzman, and Rosa del Pilar Gomez-Morales. "Biosíntesis De Nanopartículas De Feo Mediante La Acción Reductora Del Extracto De Cáscara De Mangifera Indica Y Su Aplicación En La Remoción De Metales Pesados." In The 19th LACCEI International Multi-Conference for Engineering, Education, and Technology: “Prospective and trends in technology and skills for sustainable social development” “Leveraging emerging technologies to construct the future”. Latin American and Caribbean Consortium of Engineering Institutions, 2021. http://dx.doi.org/10.18687/laccei2021.1.1.22.
Full text