Dissertations / Theses on the topic 'Shear Behaviour of SCFRC Beams'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the top 44 dissertations / theses for your research on the topic 'Shear Behaviour of SCFRC Beams.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.
Cohen, Michael I. "Structural Behaviour of Self Consolidating Steel Fiber Reinforced Concrete Beams." Thèse, Université d'Ottawa / University of Ottawa, 2012. http://hdl.handle.net/10393/23101.
Full textTian, Shichuan. "Shear behaviour of ferrocement deep beams." Thesis, University of Manchester, 2013. https://www.research.manchester.ac.uk/portal/en/theses/shear-behaviour-of-ferrocement-deep-beams(88ca7d6e-e285-4ec6-8741-da3f89047bde).html.
Full textIsmail, Kamaran Sulaiman. "Shear behaviour of reinforced concrete deep beams." Thesis, University of Sheffield, 2016. http://etheses.whiterose.ac.uk/12600/.
Full textMassam, Laurent. "The behaviour of GFRP-reinforced concrete beams in shear." Thesis, National Library of Canada = Bibliothèque nationale du Canada, 2001. http://www.collectionscanada.ca/obj/s4/f2/dsk3/ftp04/mq62954.pdf.
Full textAl-Juboori, Wissam Sadeq. "The shear behaviour of concrete beams strengthened with CFRP." Thesis, University of Salford, 2011. http://usir.salford.ac.uk/26523/.
Full text趙作周 and Zuozhou Zhao. "Nonlinear behaviour of reinforced concrete coupling beams." Thesis, The University of Hong Kong (Pokfulam, Hong Kong), 2001. http://hub.hku.hk/bib/B31243927.
Full textZhao, Zuozhou. "Nonlinear behaviour of reinforced concrete coupling beams /." Hong Kong : University of Hong Kong, 2001. http://sunzi.lib.hku.hk/hkuto/record.jsp?B23589395.
Full textKhatab, Mahmoud A. T. "Behaviour of continuously supported self-compacting concrete deep beams." Thesis, University of Bradford, 2016. http://hdl.handle.net/10454/14628.
Full textMahmoud, Karam Abdou Awad. "Shear behaviour of continuous concrete beams reinforced with GFRP bars." ASCE, 2015. http://hdl.handle.net/1993/30951.
Full textFebruary 2016
Adwan, Osama K. "Engineering properties and structural behaviour of high strength reinforced concrete beams." Thesis, University of Abertay Dundee, 1997. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.360744.
Full textChang, Ee Hui. "Shear and bond behaviour of reinforced fly ash-based geopolymer concrete beams." Curtin University of Technology, Department of Civil Engineering, 2009. http://espace.library.curtin.edu.au:80/R/?func=dbin-jump-full&object_id=120482.
Full textResearch on the development, manufacture, behaviour and applications of low calcium fly ash-based geopolymer concrete has been carried out at Curtin University of Technology since 2001. Past studies of the structural behaviour of reinforced fly ash-based geopolymer concrete members have covered the flexural behaviour of members. Further studies are needed to investigate other aspects of the structural behaviour of geopolymer concrete. Design for both shear and bond are important in reinforced concrete structures. Adequate shear resistance in reinforced concrete members is essential to prevent shear failures which are brittle in nature. The performance of reinforced concrete structures depends on sufficient bond between concrete and reinforcing steel. The present research therefore focuses on the shear and bond behaviour of reinforced low calcium fly ash-based geopolymer concrete beams.
For the study of shear behaviour of geopolymer concrete beams, a total of nine beam specimens were cast. The beams were 200 mm x 300 mm in cross section with an effective length of 1680 mm. The longitudinal tensile reinforcement ratios were 1.74%, 2.32% and 3.14%. The behaviour of reinforced geopolymer concrete beams failing in shear, including the failure modes and crack patterns, were found to be similar to those observed in reinforced Portland cement concrete beams. Good correlation of test-to-prediction value was obtained using VecTor2 Program incorporating the Disturbed Stress Field Model proposed by Vecchio (2000). An average test-to-prediction ratio of 1.08 and a coefficient of variation of 8.3% were obtained using this model. It was also found that the methods of calculations, including code provisions, used in the case of reinforced Portland cement concrete beams are applicable for predicting the shear strength of reinforced geopolymer concrete beams.
For the study of bond behaviour of geopolymer concrete beams, the experimental program included manufacturing and testing twelve tensile lap-spliced beam specimens. No transverse reinforcement was provided in the splice region. The beams were 200 mm wide, 300 mm deep and 2500 mm long. The effect of concrete cover, bar diameter, splice length and concrete compressive strength on bond strength were studied. The failure mode and crack patterns observed for reinforced geopolymer concrete beams were similar to those reported in the literature for reinforced Portland cement beams. The bond strength of geopolymer concrete was observed to be closely related to the tensile strength of geopolymer concrete. Good correlation of test bond strength with predictions from the analytical model proposed by Canbay and Frosch (2005) were obtained when using the actual tensile strength of geopolymer concrete. The average ratio of test bond strength to predicted bond strength was 1.0 with a coefficient of variation of 15.21%. It was found that the design provision and analytical models used for predicting bond strength of lapsplices in reinforced Portland cement concrete are applicable to reinforced geopolymer concrete beams.
Ahmed, Ehab Abdul-Mageed. "Shear behaviour of concrete beams reinforced with fibre-reinforced polymer (FRP) stirrups." Thèse, Université de Sherbrooke, 2009. http://savoirs.usherbrooke.ca/handle/11143/1903.
Full textLi, Ding 1969. "Behaviour and modeling of deep beams with high shear span-to-depth ratios." Thesis, McGill University, 2003. http://digitool.Library.McGill.CA:80/R/?func=dbin-jump-full&object_id=80119.
Full textThese beams were tested under concentrated load to investigate the influence of span-to-depth ratio and the influence of uniformly distributed horizontal and vertical reinforcement. The presence of uniformly distributed steel resulted in higher capacities, better crack control and also served to control bond splitting failures near the supports. Four approaches were used to predict the capacities: a plane-section model, a simplified strut-and-tie model, a model based on the 1996 FIP Recommendations and a refined strut-and-tie model. The 1996 FIP (Federation Internationale de la Precontrainte) Recommendations gave conservative predictions suitable for design. The refined strut-and-tie model gave the most accurate predictions due to the fact that this approach accounted for the contributions of both the horizontal and vertical uniformly distributed reinforcement in the strut-and-tie model.
Li, Zhen Yu 1972. "Behaviour and modeling of deep beams with low shear span-to-depth ratios." Thesis, McGill University, 2003. http://digitool.Library.McGill.CA:80/R/?func=dbin-jump-full&object_id=80122.
Full textThe test results provided information on the influence of the uniformly distributed reinforcement and the crack and strain development up to failure. The ductility of the specimens containing only the main tension ties was limited due to the formation of splitting cracks along the anchorages of the main tension ties during the later stages of testing. The uniformly distributed reinforcement provided additional tension ties that increased the capacity and the ductility. Strut-and-tie models were developed to predict the capacities. The FIP Recommendations (FIP 1996) were used to determine the contributions of the two major mechanisms, direct strut action and indirect strut action. This approach gave very conservative strength predictions. More refined strut-and-tie models were developed for the specimens with uniformly distributed reinforcement. These refined models gave more accurate predictions of the capacities of the deep beams.
Bärtschi, Roland. "Load-bearing behaviour of composite beams in low degrees of partial shear connection /." [Zürich], 2005. http://e-collection.ethbib.ethz.ch/show?type=diss&nr=15895.
Full textErnst, Stefan. "Factors affecting the behaviour of the shear connection of steel-concrete composite beams." View thesis, 2006. http://handle.uws.edu.au:8081/1959.7/32633.
Full textA thesis submitted to the University of Western Sydney, College of Health and Science, School of Engineering, in fulfilment of the requirements for the degree of Doctor of Philosophy. Includes bibliographical references.
Al-Allaf, M. H. F. "Behaviour of lightweight concrete beams strengthened with carbon fibre reinforced polymer in shear." Thesis, University of Salford, 2017. http://usir.salford.ac.uk/42441/.
Full textAli, Alameer. "Behaviour of Prestressed Ultra-High Performance Concrete I-Beams Subjected to Shear and Flexure." Thèse, Université d'Ottawa / University of Ottawa, 2013. http://hdl.handle.net/10393/24280.
Full textSuntharavadivel, Thuraichamy Guganesan. "Behaviour of shear damaged reinforced concrete beams strengthened with external post-tensioning and clamping." University of Southern Queensland, Faculty of Engineering and Surveying, 2008. http://eprints.usq.edu.au/archive/00006254/.
Full textQin, Shunde. "Shear behaviour of corroded reinforced concrete T-beams repaired with fibre reinforced polymer systems." Thesis, University of Birmingham, 2016. http://etheses.bham.ac.uk//id/eprint/6990/.
Full textYang, Fang. "Deformation behaviour of beams reinforced with fibre reinforced polymer bars under bending and shear." Thesis, University of Sheffield, 2015. http://etheses.whiterose.ac.uk/7957/.
Full textUduehi, June. "Comparative study of the structural behaviour of prestressed beams of brickwork and concrete and the shear strength of brickwork beams." Thesis, University of Edinburgh, 1989. http://hdl.handle.net/1842/11485.
Full textShalookh, Othman H. Zinkaah. "Behaviour of continuous concrete deep beams reinforced with GFRP bars." Thesis, University of Bradford, 2019. http://hdl.handle.net/10454/18381.
Full textCelada, Blesa Ulric. "Theoretical and experimental study of the behaviour at service and failure of partially prestressed concrete beams under flexure and shear." Doctoral thesis, Universitat Politècnica de Catalunya, 2019. http://hdl.handle.net/10803/668253.
Full textEl Hormigón Parcialmente Pretensado (HPP) es una estrategia de diseño intermedia entre el hormigón armado y el pretensado total el cual permite la fisuración controlada en fase de servicio; en contraposición, el hormigón totalmente pretensado se dimensiona para evitar la fisuración en servicio. Esta estrategia de diseño puede ser de gran utilidad para la optimización estructural, ya que permite una variación gradual en la rigidez, apertura de fisura, niveles tensionales y resistencia. Esta técnica ha sido estudiada durante décadas; sin embargo, su uso extensivo se ha visto limitado por la falta de metodologías para controlar el ancho de fisura. Esta Tesis busca analizar el comportamiento del HPP sometido a esfuerzos de flexión y cortante. En esta investigación, se estudia el comportamiento de elementos de hormigón parcialmente pretensado, a flexión y cortante, mediante un estudio experimental de dieciséis ensayos. Los especímenes fueron diseñados para representar las almas de puentes en cajón, de ahí la sección en doble‐T de las vigas. De los dieciséis ensayos, doce estudiaron el comportamiento a cortante del HPP y la influencia del ancho del alma, el grado de pretensado, la cuantía de armadura transversal y el trazado del pretensado. El resto de casos fueron ensayados a flexión. El objetivo de estos últimos casos fue evaluar el comportamiento a flexión, en servicio y rotura, con diferentes cuantías de armadura pasiva y activa. Para analizar el comportamiento en servicio, el protocolo de carga constaba de ciclos de carga. Los ciclos recorrían tres niveles de carga, casi‐permanente, frecuente y característico. En cada nivel se analizó y comparó la evolución de los principales parámetros para caracterizar el comportamiento de las vigas. Después de los ciclos, se aplicó una carga monotónica hasta rotura. Se analiza la bondad de diferentes modelos de resistencia a corte para el caso de elementos pretensados con alas comprimidas. De entre los diferentes modelos estudiados, el modelo de “Capacidad de Cordón Comprimido” o “Compression Chord Capacity Model” (CCCM) presentó las mejores predicciones para esta campaña experimental. Así mismo, se desarrolló una técnica fotogramétrica para analizar el patrón de la fisuración a cortante. Esta técnica permite obtener de las imágenes la separación entre fisuras, el ángulo de las fisuras y el ancho de fisura. Esta herramienta permitió generar una ecuación para predecir la cot 𝜃 en servicio y rotura. La ecuación relaciona el ángulo de las fisuras con las tensiones de compresión en el hormigón por el pretensado y su resistencia a tracción y la cuantía de armadura transversal. Con esta técnica se obtuvo la influencia entre los estribos y el ancho de las fisuras a cortante. Posteriormente, se propuso un modelo para predecir el ancho medio a cortante en servicio, usando la deformación media de los estribos, la separación entre fisuras y la inclinación de las fisuras. Las deformaciones se calcularon teniendo en cuenta la contribución a cortante de los estribos. De los resultados experimentales se concluye que, para los ensayos a cortante, las deformaciones en los estribos superan la deformación de plastificación en servicio. Lo que conlleva a grandes oberturas de fisura. Mientras que las deformaciones en la armadura longitudinal de los ensayos a flexión solo llegan a la deformación de plastificación en rotura, manteniendo deformaciones controladas en servicio.
Moraes, Rafael Santos de. "Análise teórica e experimental do comportamento ao cisalhamento de vigas em alvenaria estrutural de blocos de concreto." Universidade de São Paulo, 2017. http://www.teses.usp.br/teses/disponiveis/18/18134/tde-13032018-100759/.
Full textThis work is an in depth study about the mechanical behaviour of masonry beams subjected to shear forces. An extensive literature review, which establishes a panorama on the subject, an experimental program considering material characterization and full scale beams tests and a numerical study for the tested beams are presented. For the beams, thirty seven tests are carried out in which the influence of geometry, reinforcements ratio and a/d ratio (where a is the distance from the load to adjacent support and d is the effective depth) on the shear strength are evaluated. Computational modelling is performed using the DIANA® software in order to complement the experimental results. From the experimental and numerical results it was possible to conclude that, except for beams with 10 mm diameter steel bar, the other models failed in shear, due to the absence of stirrups or their insufficiency. An increase in longitudinal reinforcement ratio from 0,45 to 1,18% improved the theoretical shear strength in 18,4%. For the beams with two and three courses and for a/d ratios 0,77 and 1,72 it was found that there is no significant improvement on the load capacity when the transverse reinforcement ratio is increased from 0,05 to 0,07%. Shear strength mechanisms, such as the dowel action, were effective in the models load capacity. Finally, the numerical analyzes satisfactorily reproduced the experiments, regarding to the pre and post-peak behaviour and in the prediction of the ultimate load.
Alaskar, Abdulaziz. "Shear Behaviour of Slender RC Beams with Corroded Web Reinforcement." Thesis, 2013. http://hdl.handle.net/10012/7472.
Full textSuffern, Christopher Andrew. "Shear Behaviour of Disturbed Regions in Reinforced Concrete Beams with Corrosion Damaged Shear Reinforcement." Thesis, 2008. http://hdl.handle.net/10012/3933.
Full textAzam, Rizwan. "Behaviour of Shear Critical RC Beams with Corroded Longitudinal Steel Reinforcement." Thesis, 2010. http://hdl.handle.net/10012/5534.
Full textSherwood, Edward G. "One-way shear behaviour of large, lightly-reinforced concrete beams and slabs." 2008. http://link.library.utoronto.ca/eir/EIRdetail.cfm?Resources__ID=742588&T=F.
Full textQureshi, J., and Dennis Lam. "Behaviour of Headed Shear Connectors in Composite Beams with Metal Deck Profile." 2009. http://hdl.handle.net/10454/5584.
Full textThis paper presents a numerical investigation into the behaviour of headed shear stud in composite beams with profiled metal decking. A three-dimensional finite element model was developed using general purpose finite element program ABAQUS to study the behaviour of through-deck welded shear stud in the composite slabs with trapezoidal deck ribs oriented perpendicular to the beam. Both static and dynamic procedures were investigated using Drucker Prager model and Concrete Damaged Plasticity model respectively. In the dynamic procedure using ABAQUS/Explicit, the push test specimens were loaded slowly to eliminate significant inertia effects to obtain a static solution. The capacity of shear connector, load-slip behaviour and failure modes were predicted and validated against experimental results. The delamination of the profiled decking from concrete slab was captured in the numerical analysis which was observed in the experiments. ABAQUS/Explicit was found to be particularly suitable for modelling post-failure behaviour and the contact interaction between profiled decking and concrete slabs. It is concluded that this model represents the true behaviour of the headed shear stud in composite beams with profiled decking in terms of the shear connection capacity, load-slip behaviour and failure modes.
Qureshi, J., and Dennis Lam. "Behaviour of Headed Shear Stud in Composite Beams with Profiled Metal Decking." 2009. http://hdl.handle.net/10454/5585.
Full textThis paper presents a numerical investigation into the behaviour of headed shear stud in composite beams with profiled metal decking. A three-dimensional finite element model was developed using general purpose finite element program ABAQUS to study the behaviour of through-deck welded shear stud in the composite slabs with trapezoidal deck ribs oriented perpendicular to the beam. Both static and dynamic procedures were investigated using Drucker Prager model and Concrete Damaged Plasticity model respectively. In the dynamic procedure using ABAQUS/Explicit, the push test specimens were loaded slowly to eliminate significant inertia effects to obtain a static solution. The capacity of shear connector, load-slip behaviour and failure modes were predicted and validated against experimental results. The delamination of the profiled decking from concrete slab was captured in the numerical analysis which was observed in the experiments. ABAQUS/Explicit was found to be particularly suitable for modelling post-failure behaviour and the contact interaction between profiled decking and concrete slabs. It is concluded that this model represents the true behaviour of the headed shear stud in composite beams with profiled decking in terms of the shear connection capacity, load-slip behaviour and failure modes.
Qureshi, J., and Dennis Lam. "Behaviour of Headed Shear Stud in Composite Beams with Profiled Metal Decking." 2012. http://hdl.handle.net/10454/5917.
Full textHashemian, Fariborz. "Structural behaviour and optimization of moment-shaped reinforced concrete beams." 2012. http://hdl.handle.net/1993/8122.
Full textErnst, Stefan, University of Western Sydney, College of Health and Science, and School of Engineering. "Factors affecting the behaviour of the shear connection of steel-concrete composite beams." 2006. http://handle.uws.edu.au:8081/1959.7/32633.
Full textDoctor of Philosophy (PhD)
Perkins, Stephen M. J. "Shear Behaviour of Deep Reinforced Concrete Members Subjected to Uniform Load." Thesis, 2011. http://hdl.handle.net/1807/29598.
Full textSheehan, Therese, Xianghe Dai, and Dennis Lam. "Flexural behaviour of asymmetric composite beam with low degree of shear connection." 2017. http://hdl.handle.net/10454/14048.
Full textThis paper outlines an experiment on a 12 m long composite beam subjected to uniformly distributed loading. Although composite beams are widely used, current Eurocode design guidelines for these types of members can be over-conservative, particularly in relation to the required degree of shear connection. The tested beam comprised a concrete slab supported by profiled metal decking, connected to an asymmetric fabricated steel I-beam using welded shear studs. The specimen was assembled using unpropped construction methods and had a degree of shear connection equal to 33%, significantly lower than the minimum required amount specified in Eurocode 4. A uniformly distributed load was applied to the specimen, which was increased until the failure occurred characterized by yielding of the steel beam. The maximum bending moment of the composite beam obtained from the test was close to the plastic bending resistance according to the Eurocode 4. No concrete crushing or shear stud failure was observed and the end slips exceeded 6 mm, the limit for ductile behaviour in Eurocode 4. The test demonstrated the merits of unpropped construction, which are currently not fully exploited in Eurocode 4. The comparison and analysis suggest that the design limits governing the minimum degree of shear connection might be revised.
RFCS
Colalillo, Michael Anthony. "Behaviour of Shear-critical Reinforced Concrete Beams Retrofitted with Externally Applied Fibre-reinforced Polymers." Thesis, 2012. http://hdl.handle.net/1807/33967.
Full textLam, Dennis, and E. El-Lobody. "Behaviour of Headed Stud Shear Connectors in Composite Beam." 2005. http://hdl.handle.net/10454/5779.
Full textLam, Dennis, J. Qureshi, and J. Ye. "Composite behaviour of headed stud shear connectors in pairs with profiled metal deck flooring." 2010. http://hdl.handle.net/10454/5588.
Full textThis paper presents the experimental and numerical investigation into the behaviour of headed shear studs in composite beams with profiled metal deck flooring. A new single-sided horizontal push test arrangement is proposed to evaluate the shear capacity of the headed shear connectors in pairs with metal deck profiled sheeting. The characteristic resistance obtained from the horizontal push test is compared with Eurocode 4. A three-dimensional finite element model was developed using general purpose finite element program ABAQUS/Explicit. The shear connector capacity, load-slip behaviour and failure modes are validated against experimental results and close correlations were obtained.
Andermatt, Matthias. "Concrete deep beams reinforced with internal FRP." Master's thesis, 2010. http://hdl.handle.net/10048/1518.
Full textStructural Engineering
Torres, Pedro João Alves. "Comportamento de vigas geopoliméricas sujeitas ao corte." Master's thesis, 2017. http://hdl.handle.net/10316/83267.
Full textTendo em conta a realidade atual, é importante desenvolver e adotar medidas de sustentabilidade, para não colocar em causa o futuro das gerações futuras. Neste contexto, é conhecido que ao longo dos anos têm-se verificado diversos problemas no uso do cimento Portland normal CPN, tanto na vertente de impactes ambientais associados à sua produção, como nas limitações ao nível do seu desempenho mecânico, mais concretamente na sua durabilidade. Deste modo, é imperativo desenvolver materiais alternativos ao usual CPN. Sendo assim, pretende-se com este documento estudar a viabilidade de um ligante ativado alcalinamente, o metacaulino castanho, quando utilizado de forma estrutural e submetido essencialmente a esforços de corte.O estudo realizado para este documento é de caracter experimental e incide na avaliação do comportamento de vigas geopoliméricas submetidas ao corte. Para tal, desenvolveu-se uma metodologia de ensaio com 6 pontos de aplicação de carga, proporcionando simetricamente duas zonas de estudo submetidas essencialmente ao esforço transverso, reduzindo o efeito do momento fletor em cada zona.A metodologia de ensaio utilizada permitiu obter resultados bastantes satisfatórios. Entre estes, as vigas geopoliméricas demostraram ser mais dúcteis relativamente às vigas constituídas por CPN e exibiram uma degradação gradual da rigidez após a fase elástica. A mistura geopolimérica apresentou boas características de comportamento ao nível dos parâmetros analisados, embora ainda necessite de melhorar alguns aspetos para que possa ser exequível a sua utilização nas obras correntes de engenharia civil.
Given the current situation, it is important to develop and adopt sustainability measures to not jeopardize the future of next generations. In this context, it is known that over the years there have been several problems with the use of ordinary Portland cement OPC, both in terms of environmental impacts associated with its production, as well as in the limitations of its mechanical performance, more specifically its durability. Thus, it is imperative to develop alternative materials to the usual OPC. Therefore, it is intended with this document to study the viability of an alkaline activated binder, the brown metakaolin, when used in a structural way and subjected essentially to shear stresses.The study carried out for this document is experimental and focuses on the evaluation of the behavior of geopolymer beams subjected to shear. For this, a test methodology with 6 points of load application was developed, providing symmetrically two study areas submitted essentially to the shear stress, reducing the effect of the bending moment in each zone. The test methodology used allowed to obtain quite satisfactory results. Among these, the geopolymer beams proved to be more ductile with respect to the beams constituted by OPC and exhibited a gradual degradation of the stiffness after the elastic zone. The geopolymer mixture presented good behavioral characteristics in terms of the analyzed parameters, although some aspects still need to be improved so it could be used in current civil engineering works.
Universidade de Coimbra - Material e equipamento laboratorial utilizado.
Ortiz, Navas Francisco Roberto. "Effectiveness of polypropylene fibres as shear reinforcement in structural elements." Doctoral thesis, 2020. http://hdl.handle.net/10251/153147.
Full text[ES] Varias investigaciones experimentales y teóricas han sido realizadas para entender el comportamiento a cortante de elementos de hormigón y sus variables. Sin embargo, hoy en día debido a la complejidad del tema, el comportamiento a cortante de elementos de hormigón armado y en especial aquellos que no tienen refuerzo transversal, continúan sin tener una explicación clara. Por otro lado, esta complejidad del cortante aumenta cuando nuevas variables, como las fibras, se incorporan al estudio. Investigaciones han demostrado la efectividad de las fibras de acero para mejorar las propiedades mecánicas de hormigón. Según resultados experimentales, la fibra de acero mejora la resistencia cortante y ductilidad de ciertos elementos. Y en cantidades adecuadas, la fibra puede sustituir total o parcialmente los refuerzos tradicionales de cortante. Es así que varios códigos internacionales han incluido requisitos para tener a las fibras en la respuesta estructural de elementos de hormigón. Sin embargo, estos requerimientos se han creado originalmente para el hormigón reforzado con fibra de acero (Steel fibre-reinforced concrete -SFRC). Nuevas fibras con diferentes materiales y formas, como las fibras macro-sintéticas, han sido introducidas en el mercado. Estas fibras, también llamadas fibras de polipropileno o poliolefina, son una alternativa en la construcción debido a su propiedades y costo final. Inicialmente, las fibras de polipropileno eran usadas únicamente en el hormigón para controlar la fisuración por retracción. Sin embargo, en la última década la industria química ha desarrollado fibras más grandes y con mejores prestaciones de adherencia, que permiten a estas fibras cumplir con requisitos para ser utilizadas estructuralmente. En este contexto, la presente tesis pretende ser una contribución al conocimiento sobre el hormigón reforzado con fibras (Fibre-reinforced concrete - FRC), especialmente en la efectividad de las fibras de polipropileno como refuerzo a cortante. Para esto, primero se realiza un estudio bibliográfico del hormigón reforzado con fibra de polipropileno (PFRC) como material y sus aplicaciones estructurales. Este estudio también tratará sobre los parámetros que afectan el comportamiento a cortante del hormigón tradicional y hormigón reforzado con fibras. Para evaluar la efectividad de las fibras de polipropileno en el cortante, se realizarán tres campañas experimentales. Cada campaña representa un nivel de estudio diferente. El primero es a nivel material en donde se evalúa el comportamiento a cortante a través de especímenes tipo Push-off. El segundo nivel, corresponde al estudio del cortante en elementos a escala real. Para esto se fabrican y ensayan vigas esbeltas críticas a cortante. El último nivel corresponde a una aplicación real de fibras de polipropileno actuando como refuerzo cortante. En esta campaña, se fabrican y ensayan placas alveolares de gran canto con secciones y condiciones de apoyos reales.
[CA] Diverses investigacions experimentals i teòriques han estat realitzades per entendre el comportament a tallant d'elements de formigó i les seues variables. No obstant això, hui en dia a causa de la complexitat del tema, el comportament a tallant d'elements de formigó armat i especialment aquells que no tenen reforç transversal, continuen sense tindre una explicació clara. D'altra banda, aquesta complexitat del tallant augmenta quan noves variables, com les fibres, s'incorporen a l'estudi. Investigacions han demostrat l'efectivitat de les fibres d'acer per a millorar les propietats mecàniques del formigó. Segons resultats experimentals, les fibres d'acer milloren la resistència a tallant i la ductilitat de certs elements. A més, en quantitats adequades, les fibres poden substituir total o parcialment els reforços tradicionals de tallant. És així que diversos codis internacionals han inclòs requisits per a tindre amb compte la resposta estructural de les fibres en els elements de formigó. No obstant això, aquests requeriments s'han creat originalment per al formigó reforçat amb fibres d'acer (Steel fibre-reinforced concrete -SFRC). Noves fibres amb diferents materials i formes, com les fibres macro-sintètiques, han estat introduïdes al mercat. Aquestes fibres, també anomenades fibres de polipropilè o poliolefina, són una alternativa a la construcció a causa de les seues propietats i cost final. Inicialment, les fibres de polipropilè eren usades únicament en el formigó per controlar la fissuració per retracció. No obstant això, en l'última dècada, la industria química ha desenvolupat fibres més grans i amb millors prestacions d'adherència, que permeten a aquestes fibres complir amb requisits per a ser utilitzades estructuralment. En aquest context, la present tesi pretén ser una contribució al coneixement sobre el formigó reforçat amb fibres (Fibre-reinforced concrete - FRC), especialment en l'efectivitat de les fibres de polipropilè com a reforç a tallant. Per això, primer es realitza un estudi bibliogràfic del formigó reforçat amb fibres de polipropilè (PFRC) com a material i les seues plicacions estructurals. Aquest estudi també tractarà sobre els paràmetres que afecten el comportament a tallant del formigó tradicional i del formigó reforçat amb fibres. Per avaluar l'efectivitat de les fibres de polipropilè en el tallant, es realitzaran tres campanyes experimentals. Cada campanya representa un nivell d'estudi diferent. El primer és a nivell material on s'avalua el comportament a tallant a través d'espècimens tipus Push-off. El segon nivell, correspon a l'estudi del tallant en elements a escala real. Per això es fabriquen i assagen bigues esveltes crítiques a tallant. L'últim nivell correspon a una aplicació real de fibres de polipropilè actuant com a reforç a tallant. En aquesta campanya, es fabriquen i assagen plaques alveolars de gran cantell amb seccions i condicions de suports reals.
Ortiz Navas, FR. (2020). Effectiveness of polypropylene fibres as shear reinforcement in structural elements [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/153147
TESIS
Dalfré, Gláucia. "Flexural and shear strengthening of RC elements." Doctoral thesis, 2013. http://hdl.handle.net/1822/24424.
Full textIn a recent experimental program dealing with the Near Surface Mounted (NSM) technique for the flexural strengthening of continuous reinforced concrete (RC) slabs strips, the increase of load carrying and the moment redistribution was lower than the expected values. This experimental program was analysed in depth in this thesis and it was concluded that more efficient flexural strengthening arrangements can be applied if carbon fibre reinforced polymer (CFRP) laminates (of rectangular cross section) are applied not only in the intermediate support (hogging region), but also in the positive bending moment zones (sagging regions). Thus, an experimental and a numerical research program were carried out, and it was verified the possibility of increasing the load carrying capacity in 25% and 50%, maintaining a relatively high level of moment redistribution, when correct NSM flexural strengthening arrangements are used. For assessing the predictive performance of a FEM-based computer program, the experimental tests were simulated by considering the nonlinear relevant aspects of the intervening materials. After has been concluded about the capability of this model to simulate the behaviour of this type of structures, a parametric study was carried out to investigate the influence of the strengthening arrangement and CFRP percentage in terms of load carrying capacity and moment redistribution capacity of continuous RC slab strips flexurally strengthened by the NSM technique. Additionally, to predict the load-deflection response of this type of structures up to its collapse, an analytical model was developed and its performance was appraised by using the data obtained from the experimental program. This model is based on the flexibility method and requires the knowledge of the flexural stiffness of the representative cross sections of the structure, which can be determined from the moment-curvature relationship of these sections. The increase of the load carrying capacity of the strengthened slabs can, however, can be limited by the formation of a shear failure crack in the hogging region. To avoid the occurrence of this brittle failure mode, a new technique, designated Embedded Trough Section (ETS) was developed, and its effectiveness was appraised by testing two series of RC beams of different cross section. Finally, the most relevant conclusions extracted from the present study are presented, and further research developments are suggested.
Num programa experimental recentemente realizado sobre o reforço à flexão de faixas de laje contínuas de betão armado (BA) reforçadas segundo a técnica NSM (Near Surface Mounted, nomenclatura inglesa), o aumento da capacidade de carga e de redistribuição de momento foi inferior ao esperado. Este programa experimental foi analisado em profundidade nesta tese e foi concluído que existem configurações de reforço à flexão mais eficientes que podem ser utilizadas se laminados de fibra de carbono (CFRP) forem aplicados não só na região de apoio central (momento negativo), mas também na região de momentos positivos. Nesse sentido, um programa experimental e numérico foi levado a cabo, e verificou-se a possibilidade de aumentar a capacidade resistente em 25% e 50%, mantendo um nível de redistribuição de momentos relativamente elevada, quando se usam sistemas de reforço NSM adequados. Para avaliar a capacidade de previsão um software baseado no Método dos Elementos Finitos (MEF), os resultados experimentais foram simulados considerando os aspectos mais relevantes do comportamento não-linear dos materiais intervenientes. Após a conclusão deste estudo sobre a capacidade de simulação do comportamento deste tipo de estruturas com este modelo, foi realizado um estudo paramétrico para investigar a influência da disposição do reforço e da percentagem de CFRP na capacidade de carga e capacidade de redistribuição de momento em faixas de laje contínuas reforçadas segundo a técnica NSM. Além disso, um modelo analítico foi desenvolvido para prever a relação força-flecha deste tipo de estruturas até o seu colapso e o seu desempenho foi avaliado usando os dados obtidos no programa experimental. Este modelo é baseado no método de flexibilidade e pressupõe o conhecimento da rigidez à flexão das secções transversais representativas da estrutura, a qual pode ser determinada a partir da relação momento-curvatura destas secções. O aumento da capacidade de carga pode, no entanto, ser comprometido pela formação de fendas de corte junto aos apoios centrais dos elementos estruturais reforçados. Para evitar a ocorrência deste tipo de rotura frágil, uma nova técnica de reforço, designada por Embedded Trough Section (ETS, na nomenclatura inglesa) foi desenvolvida, e a sua eficácia foi avaliada por meio de ensaios de duas séries de vigas com diferentes seções transversais. Finalmente, as principais conclusões extraídas da investigação desenvolvida ao longo deste trabalho são apresentadas, e desenvolvimentos futuros são sugeridos.
Escórcio, Patrícia Carlota Costa. "Experimental and analytical study of concrete structures reinforced with GFRP bars." Doctoral thesis, 2016. http://hdl.handle.net/10400.13/1504.
Full text