Academic literature on the topic 'Shielding wires'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Shielding wires.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Shielding wires"

1

Golovko, V., O. Kotelchuk, S. Naumeiko, and Andrey A. Golyakevich. "Development of Self-Shielded Flux-Cored Wires for Arc Welding of Low-Alloy Steels." Defect and Diffusion Forum 416 (May 27, 2022): 103–14. http://dx.doi.org/10.4028/p-58v9g5.

Full text
Abstract:
Current aspects of the developing of modern self-shielding flux-cored wires composition for arc welding of low-alloyed steels are considered. Advantages and disadvantages of flux-cored wires of carbonate-fluorite, oxide and oxide-fluoride types of are shown in comparison. The effectiveness of gas shielding of molten metal at welding with self-shielding flux-cored wires of carbonate-fluorite type is analyzed considering the thermal properties of their cores. It is shown that to improve reliability of gas shielding at welding using the wires of this type it is important not only to ensure genera
APA, Harvard, Vancouver, ISO, and other styles
2

Khodadadi, A., M. H. Nazari, and S. H. Hosseinian. "Designing an Optimal Lightning Protection Scheme for Substations Using Shielding Wires." Engineering, Technology & Applied Science Research 7, no. 3 (2017): 1595–99. http://dx.doi.org/10.48084/etasr.1175.

Full text
Abstract:
An optimal lightning protection scheme for a substation using shielding wires is investigated in this paper through computer software analysis. An economic approach is utilized by choosing a reasonable trade-off between protection, the number of shielding wires and the heights of them from the ground. This study is initially applied to a simple two-wire system and then extended to a sample substation. The solution for each problem is executed in MATLAB and 3-D realization is shown.
APA, Harvard, Vancouver, ISO, and other styles
3

Khodadadi, A., M. H. Nazari, and S. H. Hosseinian. "Designing an Optimal Lightning Protection Scheme for Substations Using Shielding Wires." Engineering, Technology & Applied Science Research 7, no. 3 (2017): 1595–99. https://doi.org/10.5281/zenodo.809226.

Full text
Abstract:
An optimal lightning protection scheme for a substation using shielding wires is investigated in this paper through computer software analysis. An economic approach is utilized by choosing a reasonable trade-off between protection, the number of shielding wires and the heights of them from the ground. This study is initially applied to a simple two-wire system and then extended to a sample substation. The solution for each problem is executed in MATLAB and 3-D realization is shown.
APA, Harvard, Vancouver, ISO, and other styles
4

Mihailescu, Dănuţ, Octavian Frincu, and Marius Corneliu Gheonea. "The Comparative Analysis of Gas Emissions during Mechanized MAG Welding Using Cored Wires." Advanced Materials Research 814 (September 2013): 82–86. http://dx.doi.org/10.4028/www.scientific.net/amr.814.82.

Full text
Abstract:
The use of cored wire - shielding gas (gas mixture) pair, during mechanized Metal Active Gas - MAG welding, leads to the formation of gas emissions (CO2, CO, NOx, NO, O3 etc) which is harmful for the welder’s health. The paper addresses the experimental method applied to establish the gas emissions developed during MAG welding when rutile cored wires (standard and low fume emissions) and metal powder cored wires (standard and low fume emissions) are used. Carbon dioxide and the shielding gas mixture are investigated, too. Four types of cored wires were comparatively analysed, when three wire s
APA, Harvard, Vancouver, ISO, and other styles
5

Mihailescu, Dănuţ, Octavian Frincu, and Marius Corneliu Gheonea. "The Comparative Analysis of the Concentration of Microparticles during Mechanized MAG Welding Using Cored Wires." Advanced Materials Research 814 (September 2013): 76–81. http://dx.doi.org/10.4028/www.scientific.net/amr.814.76.

Full text
Abstract:
Use of cored wire - shielding gas (gas mixture) pair, during mechanized MAG welding, causes the microparticles formation which is harmful for the welder’s health. The paper presents the experimental method for determining the concentration of the microparticles generated during MAG welding when rutile cored wires (standard and low fume emission) and metal powder cored wires (standard and low fume emission) are used. Carbon dioxide and the shielding gas mixture are investigated, too. Four types of cored wires were comparatively analysed, when three wire speed values were applied. The research o
APA, Harvard, Vancouver, ISO, and other styles
6

Hu, Jianping, Ting Zhu, Jianlin Hu, Zhen Fang, and Ruihe Zhang. "Study on the Lightning Protection Performance for a 110 kV Non-Shield-Wired Overhead Line with Anti-Thunder and Anti-Icing Composite Insulators." Energies 16, no. 2 (2023): 815. http://dx.doi.org/10.3390/en16020815.

Full text
Abstract:
Due to micro landforms and climate, the 110 kV transmission lines crossing the mountain areas are exposed to severe icing conditions for both their high voltage (HV) conductors and shield wires during the winter. Ice accumulation on the shield wire causes excessive sag, which leads to a reduced clearance between earth and HV wires, and could eventually result in tripping of the line due to phase-to-ground flashover. Due to the lack of effective de-icing techniques for the shield wires, removing them completely from the existing overhead line (OHL) structure becomes a reasonable solution to pre
APA, Harvard, Vancouver, ISO, and other styles
7

Okada, T., K. Takahata, S. Nishijima, S. Nakagawa, and M. Yoshiwa. "Magnetic shielding with superconducting wires." IEEE Transactions on Magnetics 24, no. 2 (1988): 895–98. http://dx.doi.org/10.1109/20.11370.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Filar, Krzysztof, Artur Kawecki, Andrzej Jacek Morawski, et al. "Preparation Process of In Situ MgB2 Material with Ex Situ MgB2 Barrier to Obtain Long Sections of Superconducting Multicore Wires." Materials 18, no. 1 (2024): 126. https://doi.org/10.3390/ma18010126.

Full text
Abstract:
In the present study, our emphasis was directed towards the fabrication process of long multi-core superconducting wires, each spanning several hundred meters. These wires feature an in situ MgB2 core, an ex situ MgB2 barrier, and a copper shield. The cost-effectiveness of these constituent materials, coupled with a judicious arrangement of internal components, facilitates the utilization of an economical shielding material for the resulting wire. Our ongoing efforts have successfully yielded several hundred-meter-long wire sections possessing favorable superconducting characteristics, making
APA, Harvard, Vancouver, ISO, and other styles
9

Kuznetsov, B. I., A. S. Kutsenko, T. B. Nikitina, I. V. Bovdui, V. V. Kolomiets, and B. B. Kobylianskyi. "Method for design of two-level system of active shielding of power frequency magnetic field based on a quasi-static model." Electrical Engineering & Electromechanics, no. 2 (February 24, 2024): 31–39. http://dx.doi.org/10.20998/2074-272x.2024.2.05.

Full text
Abstract:
Aim. Development of method for design a two-level active shielding system for an industrial frequency magnetic field based on a quasi-static model of a magnetic field generated by power line wires and compensating windings of an active shielding system, including coarse open and precise closed control. Methodology. At the first level rough control of the magnetic field in open-loop form is carried out based on a quasi-static model of a magnetic field generated by power line wires and compensating windings of an active shielding system. This design calculated based on the finite element calcula
APA, Harvard, Vancouver, ISO, and other styles
10

Kuznetsov, B. I., T. B. Nikitina, I. V. Bovdui, O. V. Voloshko, V. V. Kolomiets, and B. B. Kobylianskiy. "Method of adjustment of three circuit system of active shielding of magnetic field in multi-storey buildings from overhead power lines with wires triangular arrangement." Electrical Engineering & Electromechanics, no. 1 (February 17, 2022): 21–28. http://dx.doi.org/10.20998/2074-272x.2022.1.03.

Full text
Abstract:
Aim. For the first time the method of adjustment of three circuit system of the active shielding of the magnetic field based on experimentally determined space-time characteristics to increase the shielding factor in a multi-storey building located near a single-circuit overhead transmission lines with a wires triangular arrangement was developed. Methodology. When synthesizing the laboratory model of system of active shielding the coordinates of spatial arrangement and of three shielding coils, the currents in shielding coils and resulting magnetic flux density value in the shielding space we
APA, Harvard, Vancouver, ISO, and other styles
More sources

Dissertations / Theses on the topic "Shielding wires"

1

Young, Jeffrey Lee. "Electromagnetic response of thin wires over an homogeneous earth." Diss., The University of Arizona, 1989. http://hdl.handle.net/10150/184906.

Full text
Abstract:
The electromagnetic response of infinitely long, thin wires over a flat earth is presented for two different applications: the shielding properties of an ensemble of parallel wires excited by a plane wave and the electromagnetic coupling of two perpendicular wires excited by a dipole. The shielding study begins with the formulation of the boundary value problem for N wires over a lossy half space. A suitable axial impedance operator is applied to obtain a system of equations whose unknowns are the currents flowing on each wire. Once the currents are determined, the aggregate field produced by
APA, Harvard, Vancouver, ISO, and other styles
2

Mogren, Simon. "Electromagnetic Shielding of Fine Wires for Electrophysiological Sensing." Thesis, KTH, Skolan för kemi, bioteknologi och hälsa (CBH), 2020. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-291457.

Full text
Abstract:
Tests have been performed to determine whether electromagnetic shielding of fine wires for electrophysiological sensing is a possible way to reduce the external noise in recording of nervous signals. By shielding the wires with a layer of silver, forming a coaxial cable, a reduction of the received power on the lead of 11.8-33 dBm was shown over the 10 – 10 000 Hz range when the test wire was subject to an electromagnetic field from an injection cable.  When putting the performance on the interval 50-100 Hz aside the same performance was measured to 25-33 dBm lower received power, which can be
APA, Harvard, Vancouver, ISO, and other styles
3

Lee, Robert 1962. "Electromagnetic coupling by a wire penetrating a circular aperture in an infinite planar conducting screen." Thesis, The University of Arizona, 1988. http://hdl.handle.net/10150/276731.

Full text
Abstract:
We consider the problem of electromagnetic propagation along a wire which passes through an aperture. We begin by formulating an integral equation in terms of the electric field at the aperture. The solution of the integral equation allows us to determine parameters of interest such as the equivalent admittance, the current on the wire, and the electric field. We solve the integral equation using both a zeroth order and method of moments approximation for the aperture field. From this we are able to compute the admittance and current in the frequency domain. We next calculate the current respo
APA, Harvard, Vancouver, ISO, and other styles
4

Wright, Diana Beth 1963. "Electromagnetic coupling by a wire through a cavity-backed circular aperture in an infinite screen." Thesis, The University of Arizona, 1988. http://hdl.handle.net/10150/276823.

Full text
Abstract:
The problem of a wire penetrating a circular aperture in an infinite screen and coupling energy into a cavity behind that screen is considered. We formulate an integral equation in terms of the electric field in the aperture. This integral equation is solved using two approximate methods: a zeroth-order approximation valid at low frequencies, and the method of moments. In addition, we introduce an equivalent circuit model to aid in our physical interpretation of the problem. Numerical results for the interior current on the wire and for the equivalent circuit admittance parameters are presente
APA, Harvard, Vancouver, ISO, and other styles
5

Jul, Lene. "Adding Values, Upholstery Concepts for Automotives Using Smart Textiles." Thesis, Högskolan i Borås, Institutionen Textilhögskolan, 2007. http://urn.kb.se/resolve?urn=urn:nbn:se:hb:diva-18540.

Full text
Abstract:
New textile materials are constantly being brought into the automotive field, and automobile design is a leader in innovative and spectacular developments where smart textile materials are used. The main elements of the current project are textile material research, automotive research, design and development of two upholstery concepts for automotives using smart textiles. The added values are RFI/EMI (Radio Frequency Interference / Electro Magnetic Interference) shielding qualities, light emitting, light reflective and antistatic qualities. Values in the smart-textile area are obtained throug
APA, Harvard, Vancouver, ISO, and other styles
6

Vogel, Veronika. "Endlosfaserverstärkte Thermoplaste zur Abschirmung elektromagnetischer Strahlung." Universitätsverlag Chemnitz, 2018. https://monarch.qucosa.de/id/qucosa%3A36413.

Full text
Abstract:
Durch die Ergänzung von Organoblechen mit gewebten Strukturen aus Metalldrähten können hochbelastbare Bauteile gleichzeitig mit einer abschirmenden Wirkung versehen werden und ermöglichen so Anwendungen wie beispielsweise im Umfeld der Elektromobilität. Im Rahmen der vorliegenden Arbeit wird ein polypropylen-basierter Schichtverbund aus thermoplastischen Hochleistungsfaserverbunden und Metalldrahtgewebe hinsichtlich seiner Eignung zur Abschirmung elektromagnetischer Wellen für Gehäusestrukturen und seiner Verarbeitbarkeit im Spritzgießen näher analysiert. Die Untersuchungen zeigen den Einflus
APA, Harvard, Vancouver, ISO, and other styles
7

Michel, Morgane. "Élaboration d’un fil nanocomposite PET-nanotubes de carbone pour le blindage électromagnétique : suivi de la microstructure induite par le procédé d’étirage et caractérisations des basses fréquences aux hyperfréquences." Thesis, Bourgogne Franche-Comté, 2019. http://www.theses.fr/2019UBFCK054.

Full text
Abstract:
Le principal objectif de cette thèse est de définir les conditions d’obtention de nanocomposites sous forme de fils de polyéthylène téréphtalate chargés dont la capacité d’absorbant hyperfréquence est exaltée dans le domaine 300 MHz à 3 GHz. Le procédé de fabrication de fil repose sur une technique d’extrusion qui a été adaptée de l’échelle industrielle vers l’échelle du laboratoire.Cet objectif principal se subdivise ainsi en plusieurs objectifs secondaires :Rationalisation et compréhension du procédé d’extrusion à l’échelle industrielle : les paramètres expérimentaux de la ligne d’extrusion
APA, Harvard, Vancouver, ISO, and other styles
8

Liu, Wei-Ting, and 劉韋廷. "Study on electrical and electromagnetic interference shielding effect of silver micron-size wires/particles/sheets combined with silicone." Thesis, 2018. http://ndltd.ncl.edu.tw/handle/d3pbm8.

Full text
Abstract:
碩士<br>國立臺灣科技大學<br>機械工程系<br>106<br>This paper mainly studies how to make self-made conductive adhesive with good electromagnetic shielding ability. With the rapid development of technology, various types of communication facilities, electronic devices, and electronic products are widely used, and these electronic products generate electromagnetic waves that affect electronic components and human health. Therefore, there is a need for a mask that can eliminate or reduce electromagnetic waves. Materials, while the traditional types of masking materials are mostly pure metals, but metal materials
APA, Harvard, Vancouver, ISO, and other styles
9

Liu, Kuo-Tsai, and 劉國才. "Improving the Overhead Ground Wire Shielding Angle to Enhance Transmission Line Resistant Lightning Stroke Capacity." Thesis, 2013. http://ndltd.ncl.edu.tw/handle/13950292011201482863.

Full text
Abstract:
碩士<br>國立高雄應用科技大學<br>電機工程系博碩士班<br>101<br>Lightning stroke will not only affect the quality of power supply, but also cause the damage to system equipment.The main purpose of this study is to investigate the relationship between the shielding angle of ground wire and the ability for lightning protection in overhead transmission line.We adopt the actual structure size of the on-site tower to analysis and evaluate the lightning withstand level before and after the shielding angle changed via electrical geometric model(EGM).Besides that, we use TFlash software to statistic the annual failure rate f
APA, Harvard, Vancouver, ISO, and other styles
10

Tsair, Hwang Jiin, and 黃錦財. "A Study on the Fault Responses of Pilot Wire Protective Relays and an Analysis of the Electromagnetic Shielding Properties of Pilot Wire Cables." Thesis, 1994. http://ndltd.ncl.edu.tw/handle/88865937777221712893.

Full text
Abstract:
碩士<br>國立臺灣科技大學<br>電機工程研究所<br>82<br>This thesis is to study the connections between a total blackout of Nan-Kung power station and a phase-to-ground fault at Tang-Rong Ironworks in Kaohsiung, and also to find some practical methods for solving this problem. Through investigating and measurements at several places related to the accident, it has been suggested that the electromagnetic coupling from power line fault currents to PE pilot wires nearby be most likely the link. Such acoupling ca
APA, Harvard, Vancouver, ISO, and other styles

Books on the topic "Shielding wires"

1

T͡Saliovich, A. B. Electromagnetic shielding handbook for wired and wireless EMC applications. Kluwer Academic, 1999.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
2

Tsaliovich, Anatoly. Electromagnetic Shielding Handbook for Wired and Wireless EMC Applications. Springer, 1999.

Find full text
APA, Harvard, Vancouver, ISO, and other styles

Book chapters on the topic "Shielding wires"

1

Kunkel, George M. "Shielded Wires and Cables." In Shielding of Electromagnetic Waves. Springer International Publishing, 2019. http://dx.doi.org/10.1007/978-3-030-19238-9_11.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Keller, Reto B. "Shielding." In Design for Electromagnetic Compatibility--In a Nutshell. Springer International Publishing, 2022. http://dx.doi.org/10.1007/978-3-031-14186-7_13.

Full text
Abstract:
AbstractIn the field of EMC, shields are used to: Reduce electromagnetic emissions from a product. Increase immunity against electric, magnetic, and/or electromagnetic radiation. The shielding theory presented in this book is based on the accepted shielding theory for electromagnetic waves, initially proposed by Schelkunoff ((1943) Electromagnetic waves. D. van Nostrand Company Inc, New York, pp 303–312) in 1943. The formulas in this chapter are approximations for shields with high electrical conductivity. Before we jump into the theory of shielding, here are two practical pieces of advice: Ca
APA, Harvard, Vancouver, ISO, and other styles
3

Do Carmo Lopes, Maria, and Jorge Molina Ávila. "Multiple Scattering Resonance Self-Shielding Factors in Wires." In Proceedings of the Seventh ASTM-Euratom Symposium on Reactor Dosimetry. Springer Netherlands, 1992. http://dx.doi.org/10.1007/978-94-011-2781-3_26.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Podporkin, G. V. "Improvement of Overhead Transmission Lines Lightning Protection by Line Arresters with Separate Groundings and Shielding Wires Fixed at Insulation Racks." In Lecture Notes in Electrical Engineering. Springer International Publishing, 2019. http://dx.doi.org/10.1007/978-3-030-31676-1_110.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Gräbner, Frank. "Shielding Effectiveness of a Wire Mesh." In EMC-Compatible Shielding. Springer Fachmedien Wiesbaden, 2021. http://dx.doi.org/10.1007/978-3-658-33189-4_13.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Boniszewski, Tad. "SPECIFICATIONS FOR SELF-SHIELDING WIRES." In Self-Shielded Arc Welding. Elsevier, 1992. http://dx.doi.org/10.1533/9781855730632.143.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

"Welding consumables manufacturers and their generic brand names for the self-shielding tubular wires." In Self-Shielded Arc Welding. Elsevier, 1992. http://dx.doi.org/10.1016/b978-1-85573-063-2.50015-7.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Genenko, Yuri, and Hermann Rauh. "Meissner state and critical state of thin superconductors in arbitrary paramagnetic environments: finite-element simulations." In Electromagnetics of Superconductor/Paramagnet Heterostructures. Oxford University PressOxford, 2025. https://doi.org/10.1093/9780191782855.003.0008.

Full text
Abstract:
Abstract Building on the results of Chapters 3 to 5 concerning both the flux-free Meissner state and the partially flux-filled critical state in model magnetic environments we take in this Chapter a step further towards investigations of superconductor/paramagnet heterostructures of practical relevance. To perform this, we call upon ANSYS and COMSOL, commercial finite-element programs for computing scalar, vector and tensor fields though not originally designed for modelling superconducting states, by exploiting magnetostatic-electrostatic analogues. The conditions of both an imposed transport
APA, Harvard, Vancouver, ISO, and other styles
9

Zinke, Manuela, Stefan Burger, and Sven Juettner. "Properties of Additively Manufactured Deposits of Alloy 718 Using CMT Process Depending on Wire Batch and Shielding Gas." In Welding Principles and Application [Working Title]. IntechOpen, 2022. http://dx.doi.org/10.5772/intechopen.102455.

Full text
Abstract:
Wire + arc additive manufacturing (WAAM®) is a versatile, low-cost, energy-efficient technology used in metal additive manufacturing (AM). This process uses arc welding to melt a wire and form a three-dimensional (3D) object using a layer-by-layer deposit. In the present study, the effect of heat input and shielding gas during CMT-WAAM welding on cooling time, mechanical properties at room temperature, and macro- and microstructure was investigated based on different part geometries (wall, block) using two S Ni 7718 wire batches. The heat input and consequently the cooling rate were varied by
APA, Harvard, Vancouver, ISO, and other styles
10

Parmantier, Jean Philippe, and Pierre Degauque. "Topology Based Modelling Of Very Large Systems." In Modern Radio Science 1996. Oxford University PressOxford, 1996. http://dx.doi.org/10.1093/oso/9780198565307.003.0007.

Full text
Abstract:
Abstract The theory relies on decomposition of the geometry of the problem in different volumes included within each other (see Fig. 1). This breakdown is made possible thanks to the “Good Shielding Approximation” principle, which supposes that inner volumes cannot interact with external volumes [Baum, 1989]. In practise, such a breakdown is not realistic. Indeed, wi1es are inevitably present in systems, and make the volumes “electromagnetically” dependent.
APA, Harvard, Vancouver, ISO, and other styles

Conference papers on the topic "Shielding wires"

1

Sowa, Andrzej. "Shielding Effectivenes of Conductive Wires Over the Underground Railway Lines." In EMC_1986_Wroclaw. IEEE, 1986. https://doi.org/10.23919/emc.1986.10828442.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Demoulin, B., I. Bacancios, L. Kone, and C. Munteanu. "Study of the Transfer Impedance and Shielding Effectiveness of Cable Trays for Industrial Wires." In 2006_EMC-Europe_Barcelona. IEEE, 2006. https://doi.org/10.23919/emc.2006.10813264.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Large, D., F. Scandella, A. Robineau, et al. "Welding of Lean Duplex Stainless Steel Grades: Microstructure, Corrosion Resistance and Mechanical Properties." In CORROSION 2012. NACE International, 2012. https://doi.org/10.5006/c2012-01097.

Full text
Abstract:
Abstract Recent price fluctuations of raw materials such as chromium and nickel have led to the development of stainless steel grades containing less nickel, which are known as lean duplex stainless steels. A research project has been initiated involving stainless steel manufacturers and end-users in order to study the weldability and properties of such grades. Investigations have been carried out on three lean duplex grades: UNS S32101, UNS S32202 and UNS S32304. Test pieces have been welded using several arc welding processes: Gas Tungsten Arc Welding (GTAW), Gas Metal Arc Welding (GMAW) usi
APA, Harvard, Vancouver, ISO, and other styles
4

Losito, Onofrio, Vincenzo Dimiccoli, and Domenico Barletta. "Magnetic Shielding Effectiveness of Multilayer Wire Mesh Screen." In 2010_EMC-Europe_Wroclaw. IEEE, 2010. https://doi.org/10.23919/emc.2010.10826284.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Jiang, Quanfeng, Qiang-Ming Cai, Jincheng Tang, et al. "Study on Shielding Efficiency of Metal Wire Mesh for Cable Joints." In 2024 Photonics & Electromagnetics Research Symposium (PIERS). IEEE, 2024. http://dx.doi.org/10.1109/piers62282.2024.10617963.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Gao, Changzheng, Lin Li, Xiang Cui, Zhibin Zhao, and Xuesong Gu. "Calculation of the Shielding Effectiveness of Reinforcing Wire Mesh Using NEC." In 2004_EMC-Europe_Eindhoven. IEEE, 2004. https://doi.org/10.23919/emc.2004.10805931.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Yamane, Hiroshi, Yuji Maeda, and Masamitsu Tokuda. "Influence of Extension Lines on Electromagnetic Shielding Effects of the Wire-Mesh Frame Structure." In 11th International Zurich Symposium and Technical Exhibition on Electromagnetic Compatibility. IEEE, 1995. https://doi.org/10.23919/emc.1995.10784191.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Fan, Conghao, Wenjun Sun, Haoxin Wan, Xunwang Zhao, and Xifeng Pu. "Research on shielding effectiveness of field-to-wire coupling model based on time-domain hybrid method." In 2024 International Applied Computational Electromagnetics Society Symposium (ACES-China). IEEE, 2024. http://dx.doi.org/10.1109/aces-china62474.2024.10699736.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Ali Al Ghamdi, Mohammed. "Effect of Heat Treatment on Mechanical Properties of ATIG Welded Aluminum Alloy." In MPWT 2019. NACE International, 2019. https://doi.org/10.5006/mpwt19-14282.

Full text
Abstract:
Abstract The 6XXX aluminum alloys are magnesium and silicon alloys that are widely used in several applications for their attractive mechanical properties. However, there are some problems associated with the welding of aluminum alloys. Aluminum alloys are difficult to weld due to their high thermal conductivity and high thermal expansion. The weldability of aluminum alloys varies significantly, depending on its chemical composition. In this paper, an experimental investigation studies the effect of heat treatment on mechanical properties of 6063 aluminum alloy for a single pass of Activated T
APA, Harvard, Vancouver, ISO, and other styles
10

Payares, Lily Margareth, Virginia Paredes Méndez, Margareth Dugarte, Juan Carlos Rincón Montenegro, and Lizeth Gutiérrez Púa. "Use of the Microalgae Chlorella Sp. to Biofunctionalized Magnesium Surfaces in Order to Decrease the Rate of Corrosion and Promote the Bone Remodeling Process." In CONFERENCE 2022. AMPP, 2022. https://doi.org/10.5006/c2022-18514.

Full text
Abstract:
Extended Abstract Frequently, the human body is susceptible to injuries such as the fracture of one or more of its bones, so it is necessary to use implants or some fixation element to keep the fragments of the fracture together, allowing an orderly repair that facilitates healing or compensates the lack or loss of bone tissue. Temporary orthopedic implants have been used clinically to repair broken or fractured bones during the healing process. The most used are plates, screws, nails, wires, and intramedullary nails. It is usually necessary to perform operations to open the injury site, join
APA, Harvard, Vancouver, ISO, and other styles

Reports on the topic "Shielding wires"

1

Wang, T. S. F. The space-charge impedance of RF-shielding wires. Office of Scientific and Technical Information (OSTI), 1998. http://dx.doi.org/10.2172/304135.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Author, Unknown. L51610 Pulsed Gas Metal Arc Welding of API 5LX-80 Pipe. Pipeline Research Council International, Inc. (PRCI), 1989. http://dx.doi.org/10.55274/r0010413.

Full text
Abstract:
This research program was undertaken to investigate the use of the pulsed- gas metal-arc welding (PGMAW) process for the field, girth welding of API 5LX-80 pipe. The specific program objectives were as follows: Determine the optimum shielding in gas, commercial filler wire, and weld procedure for the PGMA girth 5LX -80 pipe welding in the 5G position of API to determine the mechanical properties of PGMA girth welds deposited in five, API 5LX-80 pipes manufactured by different pipe mills. This report summarizes the materials, equipment, and procedures used, the results obtained, a discussion of
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!