Academic literature on the topic 'SICU'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'SICU.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "SICU"

1

McCarthy, M. C., A. J. Apponi, C. A. Gottlieb, and P. Thaddeus. "Laboratory Detection of Five New Linear Silicon Carbides: SiC3, SiC5, SiC6, SiC7, and SiC8." Astrophysical Journal 538, no. 2 (2000): 766–72. http://dx.doi.org/10.1086/309177.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Hansen, Jeff, Bonnie Marty, Juliana Barr, and Eran Geller. "REDUCTION IN DRUG EXPENDITURES BY SICU TEAM AND SICU PHARMACOTHERAPISTS." Critical Care Medicine 23, Supplement (1995): A31. http://dx.doi.org/10.1097/00003246-199501001-00022.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Nishi, Gregg K., Richard H. Suh, Matthew T. Wilson, Scott A. Cunneen, Daniel R. Margulies, and M. Michael Shabot. "Analysis of Causes and Prevention of Early Readmission to Surgical Intensive Care." American Surgeon 69, no. 10 (2003): 913–17. http://dx.doi.org/10.1177/000313480306901019.

Full text
Abstract:
The purpose of this study was to analyze causes of early readmission to the surgical intensive care unit (SICU), to determine whether readmission can be predicted or prevented, and to compare outcomes of patients readmitted to the SICU with patients not requiring readmission. All patients admitted to the Cedars-Sinai SICU from January 1, 1996, to December 31, 2001, were included. Clinical data was prospectively collected in an on-line computer system. The charts of all early readmission patients were retrospectively reviewed. SICU and hospital outcomes were abstracted from a computerized data
APA, Harvard, Vancouver, ISO, and other styles
4

Wilson, Matthew T., Kenneth L. Crawford, and M. Michael Shabot. "Intensive Care Unit Outcomes of Surgical Centenarians: The “Oldest Old” of the New Millennium." American Surgeon 66, no. 9 (2000): 870–73. http://dx.doi.org/10.1177/000313480006600916.

Full text
Abstract:
This study compared the severity of illness and outcomes of surgical intensive care unit (SICU) patients age 100 years or older with those of younger SICU patients. Severity of illness was measured with the Simplified Acute Physiology Score (SAPS) and the Quantified Therapeutic Intervention Scoring System (QTISS). Outcomes were evaluated with SICU length of stay (LOS), hospital LOS, SICU mortality, and hospital mortality. All patients admitted to an urban, tertiary-care SICU from August 1, 1986 to July 31, 1998 (12 years) were included. A total of 24,395 consecutive patients were evaluated of
APA, Harvard, Vancouver, ISO, and other styles
5

Koss, Wega G., Theodore M. Khalili, Julio F. Lemus, Marjorie M. Chelly, Daniel R. Margulies, and M. Michael Shabot. "Nosocomial Pneumonia is Not Prevented by Protective Contact Isolation in the Surgical Intensive Care Unit." American Surgeon 67, no. 12 (2001): 1140–44. http://dx.doi.org/10.1177/000313480106701205.

Full text
Abstract:
Nosocomial pneumonia (NP) is the leading cause of death from hospital-acquired infection in intubated surgical intensive care unit (SICU) patients. To determine whether protective contact isolation would lower the incidence of NP in intubated patients we performed a prospective, randomized, and controlled study in two SICUs in a tertiary medical center. Over a period of 15 months two identical ten-bed SICUs alternated for 3-month periods between protective contact isolation (isolation group) and standard “universal precautions” (control group). In the isolation group all personnel and visitors
APA, Harvard, Vancouver, ISO, and other styles
6

Abbott, Kenneth L., Philip Hong, Matthew M. Ruppert, et al. "Surgical ICU Admission Criteria: A Scoping Review." Critical Care Explorations 7, no. 7 (2025): e1278. https://doi.org/10.1097/cce.0000000000001278.

Full text
Abstract:
OBJECTIVES: The aims of this scoping review were to: 1) explore factors driving surgical ICU (SICU) admission decisions, 2) provide an environmental scan of SICU admission practices, and 3) identify underexamined domains relevant for SICU triage, admission, and discharge inquiries. DATA SOURCES: Embase, PubMed, and Medline were queried from inception to April 18, 2024, for English-language peer-reviewed studies related to adult SICU admission criteria and decision-making; neonatal ICU, PICU, veterinary ICU, and military ICU data and gray literature were excluded. Studies were not limited by de
APA, Harvard, Vancouver, ISO, and other styles
7

Koenig, William, Kathleen Adams, David Platt, A. David Drezner, and Rocco Orlando. "FUNGAL INFECTIONS IN THE SICU." Critical Care Medicine 14, no. 4 (1986): 330. http://dx.doi.org/10.1097/00003246-198604000-00046.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Grindlinger, G. A., R. Cachecho, S. Wedel, R. Dennis, and F. Millham. "Inadvertant Extubation in the SICU." Critical Care Medicine 21, no. 1 (1993): A159. http://dx.doi.org/10.1097/00003246-199301000-00035.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Fridkin, Scott K., Suzanne M. Pear, Theresa H. Williamson, John N. Galgiani, and William R. Jarvis. "The Role of Understaffing in Central Venous Catheter-Associated Bloodstream Infection." Infection Control & Hospital Epidemiology 17, no. 3 (1996): 150–58. http://dx.doi.org/10.1017/s0195941700006445.

Full text
Abstract:
AbstractObjective:To determine risk factors for central venous catheter-associated bloodstream infections (CVC-BSI) during a protracted outbreak.Design:Case-control and cohort studies of surgical intensive care unit (SICU) patients.Setting:A university-affiliated Veterans Affairs medical center.Patients:Case-control study: all patients who developed a CVC-BSI during the outbreak period (January 1992 through September 1993) and randomly selected controls. Cohort study: all SICU patients during the study period (January 1991 through September 1993).Measurements:CVC-BSI or site infection rates, S
APA, Harvard, Vancouver, ISO, and other styles
10

Dexter, F., K. Pearson, D. L. Griffiths, and P. Jebson. "Surgical ICU Underutilization Does not Significantly Discourage Discharge." Health Services Management Research 9, no. 4 (1996): 238–42. http://dx.doi.org/10.1177/095148489600900403.

Full text
Abstract:
An SICU must have sufficient capacity to handle peak weekly demand to prevent re-admission and/or poor quality of care. Excess capacity may, however, encourage unnecessary SICU utilization. The goal of this study was to assess the influence of availability of SICU beds on patient discharge and re-admission rates. The case series included 1,492 days, 36,816 patient days, 8,821 discharges, and 186 re-admissions within 3 days from a 24-bed multidisciplinary SICU at a tertiary care center. Census was defined to equal the total number of patients in the SICU each day. We found low census levels wer
APA, Harvard, Vancouver, ISO, and other styles
More sources

Dissertations / Theses on the topic "SICU"

1

Guido-Sanz, Francisco. "The Effects of Advanced Practice Nurses (APNs) as Intensivists in a Surgical Intensive Care Unit (SICU) on Patient Outcomes, Healthcare Charges, and APN Intensivist Services in the SICU." FIU Digital Commons, 2014. http://digitalcommons.fiu.edu/etd/1544.

Full text
Abstract:
Intensive Care Units (ICUs) account for over 10 percent of all US hospital beds, have over 4.4 million patient admissions yearly, approximately 360,000 deaths, and account for close to 30% of acute care hospital costs. The need for critical care services has increased due to an aging population and medical advances that extend life. The result is efforts to improve patient outcomes, optimize financial performance, and implement models of ICU care that enhance quality of care and reduce health care costs. This retrospective chart review study examined the dose effect of APN Intensivists in a su
APA, Harvard, Vancouver, ISO, and other styles
2

Rudnick, Wendy C. "Relationship of a structured information transfer process for family members of patients transferred from SICU to an in-patient unit on transfer anxiety." Thesis, National Library of Canada = Bibliothèque nationale du Canada, 2000. http://www.collectionscanada.ca/obj/s4/f2/dsk1/tape4/PQDD_0022/MQ51794.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Liebau-Kunzmann, Verena. "Funktionalisierte polymerabgeleitete Keramiken in den ternären Systemen SiCO und SiCN." Aachen Shaker, 2008. http://d-nb.info/995887926/04.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Rohmer, Eric. "Caractérisation et modélisation mécanique de tubes composites sicf/sic." Phd thesis, Université Sciences et Technologies - Bordeaux I, 2013. http://tel.archives-ouvertes.fr/tel-00966267.

Full text
Abstract:
Ce travail s'inscrit dans un contexte de développement des réacteurs de quatrième génération. Il concerne plus particulièrement la partie composite du gainage tubulaire de type sandwich envisagé par le CEA pour les réacteurs RNR-NA/Gaz. Le renfort est mis en forme par tressage et l'étude se focalise sur des composites tressés interlocks. Ces structures relativement nouvelles nécessitent une caractérisation mécanique poussée. Deux protocoles expérimentaux ont été développés permettant la réalisation d'essais de traction et de pression interne sur tube. Trois textures différentes ont ainsi été c
APA, Harvard, Vancouver, ISO, and other styles
5

Huguet-Garcia, Juan Francisco. "In situ and ex situ characterization of the ion-irradiation effects in third generation SiC fibers." Thesis, Paris 6, 2015. http://www.theses.fr/2015PA066221/document.

Full text
Abstract:
L'utilisation des fibres SiC Tyranno SA3 (TSA3) et Hi Nicalon S (HNS) pour le renforcement de composites céramiques dédiées aux applications nucléaires impose l'étude de leur stabilité microstructurale et de leur comportement mécanique sous irradiation. La cinétique d'amorphisation des fibres a été étudiée et comparée à celle d'un matériau modèle, 6H-SiC monocristallin, sans que des différences significatives puissent être observées. La dose seuil d'amorphisation totale a été évaluée à ~0,4 dpa à température ambiante et aucune amorphisation complète n'a pas être obtenue pour des températures d
APA, Harvard, Vancouver, ISO, and other styles
6

Huguet-Garcia, Juan Francisco. "In situ and ex situ characterization of the ion-irradiation effects in third generation SiC fibers." Electronic Thesis or Diss., Paris 6, 2015. http://www.theses.fr/2015PA066221.

Full text
Abstract:
L'utilisation des fibres SiC Tyranno SA3 (TSA3) et Hi Nicalon S (HNS) pour le renforcement de composites céramiques dédiées aux applications nucléaires impose l'étude de leur stabilité microstructurale et de leur comportement mécanique sous irradiation. La cinétique d'amorphisation des fibres a été étudiée et comparée à celle d'un matériau modèle, 6H-SiC monocristallin, sans que des différences significatives puissent être observées. La dose seuil d'amorphisation totale a été évaluée à ~0,4 dpa à température ambiante et aucune amorphisation complète n'a pas être obtenue pour des températures d
APA, Harvard, Vancouver, ISO, and other styles
7

Duquesne, Loys. "Caractérisation thermique de structures composites SiCf/SiC tubulaires pour applications nucléaires." Thesis, Paris, ENSAM, 2015. http://www.theses.fr/2015ENAM0052/document.

Full text
Abstract:
Les recherches portant sur le développement des composites réfractaires de type SiCf/SiC pour application gainage du combustible des réacteurs de géneration IV ont conduit le CEA à s’intéresser aucomportement thermique de ces matériaux. En particulier, la connaissance des propriétés thermiques représente un des points cles dans la conception des composants. Au regard du concept sandwichdont la complexité de structure et la géométrie cylindrique s'éloigne de celle d'éprouvettes planes classiquement utilisées, les méthodes de mesures usuelles ne conviennent pas.Ce travail de thèse s’intéresse à
APA, Harvard, Vancouver, ISO, and other styles
8

Heatwole, Scott. "In situ infrared diagnositics [sic] for a micro-scale combustion reactor." College Park, Md. : University of Maryland, 2004. http://hdl.handle.net/1903/1848.

Full text
Abstract:
Thesis (M.S.) -- University of Maryland, College Park, 2004.<br>Thesis research directed by: Dept. of Mechanical Engineering. Title from t.p. of PDF. Includes bibliographical references. Published by UMI Dissertation Services, Ann Arbor, Mich. Also available in paper.
APA, Harvard, Vancouver, ISO, and other styles
9

Josiek, Andrei. "CVD dans le système CH₃SiCl₃/H₂ : cinétiques expérimentales de dépôt de SiC et SiC+Si, modélisation." Bordeaux 1, 1995. http://www.theses.fr/1995BOR10613.

Full text
Abstract:
LE DEPOT CHIMIQUE EN PHASE VAPEUR (CVD) DE CERAMIQUES A BASE DE CARBURE DE SILICIUM (SIC) A PARTIR DU MELANGE CH₃SiCl₃/H₂ A ETE ETUDIE POUR DES PRESSIONS TOTALES ET DES TEMPERATURES RELATIVEMENT BASSES (P0 KPA, T75C). L'INFLUENCE DU TEMPS DE SEJOUR DES GAZ DANS LA ZONE CHAUDE DU REACTEUR SUR LA VITESSE DE DEPOT DE SIC A ETE EXAMINEE. UNE TRANSITION ABRUPTE ENTRE DEUX CINETIQUES DE DEPOT DIFFERENTES (CORRESPONDANT AU DEPOT DE SIC OU DE SIC+SI), INDUITE PAR VARIATION D'UN PARAMETRE EXPERIMENTAL, A ETE DETECTEE. LA LOCALISATION DE L'EXCES DE SI DANS LE DEPOT A ETE ETUDIEE AU PLAN THEORIQUE ET EXP
APA, Harvard, Vancouver, ISO, and other styles
10

Liebau-Kunzmann, Verena [Verfasser]. "Funktionalisierte polymerabgeleitete Keramiken in den ternären Systemen SiCO und SiCN / Verena Liebau-Kunzmann." Aachen : Shaker, 2009. http://d-nb.info/1159833575/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
More sources

Books on the topic "SICU"

1

Bierema, Elizabeth. 2J, the surgical intensive care unit (SICU). U.S. Department of Health and Human Services, Public Health Service, National Institutes of Health, Clinical Center, 1989.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
2

Elizabeth, Bierema, and National Institutes of Health (U.S.). Clinical Center, eds. 2J, the surgical intensive care unit (SICU). U.S. Dept. of Health and Human Services, Public Health Service, National Institutes of Health, Clinical Center, 1989.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
3

Dohrn, Zayd. Sick. Samuel French, 2012.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
4

Cohn, Jonathan. Sick. HarperCollins, 2007.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
5

Bonansinga, Jay R. Sick. Orion, 1995.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
6

Indonesia. Direktorat Pembinaan Pengelolaan Lingkungan Hidup., ed. Profil situ-situ di wilayah Jabotabek. Direktorat Pembinaan Pengelolaan Lingkungan Hidup, Direktorat Jenderal Pembangunan Daerah, Departemen Dalam Negeri, 1998.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
7

Marc, Lipton, ed. Sick & tired of being sick & tired. Wynwood Press, 1989.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
8

Berenstain, Jan. Sick days. HarperFestival, 2009.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
9

David, McPhail. Sick day. Holiday House, 2012.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
10

Gaudiani, Jennifer L. Sick Enough. Routledge, 2018. http://dx.doi.org/10.4324/9781351184731.

Full text
APA, Harvard, Vancouver, ISO, and other styles
More sources

Book chapters on the topic "SICU"

1

Mann, S., S. Wiedmann, U. Mann, H. Zirngibl, and K. W. Jauch. "Qualitätssicherung auf der SICU mittels weitgehend automatisierter Datenerfassung." In Klinik und Forschung in der Chirurgie unter dem Aspekt von Effizienz und Ökonomie. Springer Berlin Heidelberg, 1997. http://dx.doi.org/10.1007/978-3-642-60881-0_451.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Imhoff, M. "One Year Experience with a Unix-Based Clinical Information System (CIS) on an SICU." In Intensivmedizinisches Seminar. Springer Vienna, 1993. http://dx.doi.org/10.1007/978-3-7091-9320-4_8.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Xie, Yupeng, Laifei Cheng, Jie Jian, Yanan Xie, and Litong Zhang. "Strengthening/Toughening of Laminated (SiCw +SiCp )/SiC Ceramic Composites." In Ceramic Transactions Series. John Wiley & Sons, Inc., 2014. http://dx.doi.org/10.1002/9781118932995.ch76.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Polat, B. Deniz, and Ozgul Keles. "Si and SiCu Three Dimensional Sculptured Films as Negative Electrodes for Rechargeable Lithium Ion Batteries." In TMS 2016 145th Annual Meeting & Exhibition. Springer International Publishing, 2016. http://dx.doi.org/10.1007/978-3-319-48254-5_60.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Polat, B. Deniz, and Ozgul Keles. "Si AND SiCu Three Dimensional Sculptured Films as Negative Electrodes for Rechargeable Lithium Ion Batteries." In TMS 2016: 145thAnnual Meeting & Exhibition: Supplemental Proceedings. John Wiley & Sons, Inc., 2016. http://dx.doi.org/10.1002/9781119274896.ch60.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Polat, B. Deniz, Ceren Yagsi, and Ozgul Keles. "Thickness Effect on the Three-Dimensional Sculptured SiCu Thin Films Used as Negative Electrodes in Lithium Ion Batteries." In TMS 2016 145th Annual Meeting & Exhibition. Springer International Publishing, 2016. http://dx.doi.org/10.1007/978-3-319-48254-5_61.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Polat, B. Deniz, Ceren Yagsi, and Ozgul Keles. "Thickness Effect on the Three-Dimensional Sculptured SiCu Thin Films Used as Negative Electrodes in Lithium Ion Batteries." In TMS 2016: 145thAnnual Meeting & Exhibition: Supplemental Proceedings. John Wiley & Sons, Inc., 2016. http://dx.doi.org/10.1002/9781119274896.ch61.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Lee, Kang N. "Environmental Barrier Coatings for SiCf/SiC." In Ceramic Matrix Composites. John Wiley & Sons, Inc., 2014. http://dx.doi.org/10.1002/9781118832998.ch15.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Riccardi, B., C. A. Nannetti, J. Woltersdorf, E. Pippel, and T. Petrisor. "High Temperature Brazing for SiC and SiCf /SiC Ceramic Matrix Composites." In Ceramic Transactions Series. John Wiley & Sons, Inc., 2012. http://dx.doi.org/10.1002/9781118406014.ch28.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Jia, Xin-Lei, Jian-Cheng Liu, Ying Meng, Shi-Dong Kang, and Xin-Hao Jiang. "Microstructure Analysis of SiC Ceramics and SiCf/SiC Composites by Diffusion Bonding." In Springer Proceedings in Physics. Springer Singapore, 2019. http://dx.doi.org/10.1007/978-981-13-5947-7_11.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Conference papers on the topic "SICU"

1

Strahringer, David, Kevin Ladentin, Withek Razgaoui, and Rüdiger Quay. "In-Situ Condition Monitoring of SiC-MOSFETs During Active Power Cycling Using Acoustic Emission Testing." In 2024 19th International Microsystems, Packaging, Assembly and Circuits Technology Conference (IMPACT). IEEE, 2024. https://doi.org/10.1109/impact63555.2024.10818920.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Bavarian, Behzad B., S. Metha, C. Davison, B. Aguilar, and Mehrooz Zamanzadeh. "Evaluation of the Environmentally Assisted Cracking of Aluminum-Metal Matrix Composites in Marine Enviroment." In CORROSION 1993. NACE International, 1993. https://doi.org/10.5006/c1993-93285.

Full text
Abstract:
Abstract A series of mechanical and electrochemical experiments were performed on samples of 6091 + 25% SiCp and 6092 + 25% SiCp in oder to investigate potential applications for these promisyng materials in the high speed aircrafts such as Hogh Speed Civil Transport(HSCT). The objective of these experiments was to evaluate the susceptibility of these materials to environment induced cracking in marine environment. Variables examined include pH, applied potential, and concentration of cholride ions. Results of these investigation showed these materials to be susceptible to stress corrosion cra
APA, Harvard, Vancouver, ISO, and other styles
3

Mankena, Santosh Vardhan Reddy, V. S. Yashwanth Kumar, Sai Rithwik Pokala, et al. "SICU Ambience and Patient Health Monitoring System with IOT principles." In 2021 Second International Conference on Electronics and Sustainable Communication Systems (ICESC). IEEE, 2021. http://dx.doi.org/10.1109/icesc51422.2021.9532926.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Huff, T., J. Johnson, and A. Martin. "Ceftazadime-Resistant Gran-Negative Rods in MICU and SICU Patients." In Minority Trainee Research Forum, 2004. TheScientificWorld Ltd, 2004. http://dx.doi.org/10.1100/tsw.2004.169.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Muhammed, Abdul Khader, Tahar Najeh, Rim Mnasri, et al. "198 Safe post-surgical ventilated patient transfer to SICU using checklists." In International Forum on Quality and Safety in Healthcare - Utrecht 2025. British Medical Journal Publishing Group, 2025. https://doi.org/10.1136/bmjoq-2025-qshu.198.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Bache, M. R., P. I. Nicholson, and E. Williams. "In-Situ Assessment of Fracture in SiCf/SiC Under Computed X-Ray Tomography." In ASME Turbo Expo 2018: Turbomachinery Technical Conference and Exposition. American Society of Mechanical Engineers, 2018. http://dx.doi.org/10.1115/gt2018-75795.

Full text
Abstract:
The use of X-ray computed tomography (XCT) for detecting sub-critical damage and ultimate failure mechanisms in a ceramic matrix composite is demonstrated. To this end, an initial XCT investigation of a CMC sample, using a commercially available in-situ mechanical loading rig, is presented. As an important step toward a better understanding of the mechanical behaviour of these materials, in-situ XCT inspection was performed on a macroscopic scaled test coupon, i.e. sampling a significant number of fibre bundles, whilst the material was subjected to monotonic tensile load. The observation of in
APA, Harvard, Vancouver, ISO, and other styles
7

Huang, C. Z., H. L. Liu, J. Wang, and Z. W. Liu. "Study on Mechanical Properties of Multi-Scale and Multi-Phase Nanocomposite Ceramic Tool Materials." In ASME 2006 International Manufacturing Science and Engineering Conference. ASMEDC, 2006. http://dx.doi.org/10.1115/msec2006-21054.

Full text
Abstract:
The single nano-scale and multi-phase nanocomposite ceramic materials including Al2O3/Al2O3n/SiCn and Al2O3/Ti(C0.7N0.3)n/SiCn are successfully fabricated. Their mechanical properties are better than those of the single-phase alumina material and conventional alumina matrix materials. The multi-scale and single-phase nanocomposite ceramic tool material Al2O3/SiCμ/SiCn is also successfully fabricated. Its flexural strength and fracture toughness is higher than those of single-scale materials Al2O3/SiCμ and Al2O3/SiCn. The multi-scale and multi-phase nanocomposite ceramic tool material Al2O3/TiC
APA, Harvard, Vancouver, ISO, and other styles
8

Hameed, Fareeha, Roberto Fedele, and Lucia Mancini. "Analysis of a SiCf/SiC sample under in situ loading by synchrotron x-ray radiation." In INTERNATIONAL CONFERENCE OF COMPUTATIONAL METHODS IN SCIENCES AND ENGINEERING ICCMSE 2020. AIP Publishing, 2021. http://dx.doi.org/10.1063/5.0047746.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Weston, Eleri, P. Ian Nicholson, Stephen Pattison, and Martin Bache. "Mechanical Damage Accumulation in SiCf/SiC CMCs Characterised via In-Situ Computed X-Ray Tomography." In ASME Turbo Expo 2019: Turbomachinery Technical Conference and Exposition. American Society of Mechanical Engineers, 2019. http://dx.doi.org/10.1115/gt2019-90357.

Full text
Abstract:
Abstract The use of an in-situ loading stage combined with an X-ray computed tomography (XCT) system is demonstrated for detecting sub-critical damage and ultimate failure mechanisms in a 0/90° continuous fibre reinforced SiCf/SiC ceramic matrix composite. XCT inspection was performed on macroscopic scaled test coupons sampling a significant number of fibre tows, whilst the material was subjected to monotonic tensile load, both static and cyclic in nature. The observation of inherent, post-processing features and the tracking of the resultant damage within the composite were demonstrated, supp
APA, Harvard, Vancouver, ISO, and other styles
10

Jordan, Steven P., Martin R. Bache, Christopher D. Newton, and Louise Gale. "Characterisation of SiCf/SiC Specimens Using an In-Situ Tensile Stage Within a Scanning Electron Microscope." In ASME Turbo Expo 2019: Turbomachinery Technical Conference and Exposition. American Society of Mechanical Engineers, 2019. http://dx.doi.org/10.1115/gt2019-90356.

Full text
Abstract:
Abstract The present paper will introduce the use of scanning electron microscope based, in-situ tensile testing as a method of detecting cracking in a SiCf/SiC CMC at room temperature. Small scale tensile specimens were prepared, but still sampling multiple longitudinal and transverse fibre tows. Monotonic loading was applied to initiate cracking, whilst contemporary time lapse imaging and retrospective digital image correlation recorded the development of these cracks at the specimen surface. Examples of strain localization, crack initiation and propagation will be presented for a plain gaug
APA, Harvard, Vancouver, ISO, and other styles

Reports on the topic "SICU"

1

Cao, J. In situ toughened SiC ceramics with Al-B-C additions and oxide-coated SiC platelet/SiC composites. Office of Scientific and Technical Information (OSTI), 1996. http://dx.doi.org/10.2172/414374.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Covavisaruch, Sirijutaratana. Comparison of mechanical behaviors of microwave and thermal cured on SiC whisker-filled polybenzoxazine. Chulalongkorn University, 2006. https://doi.org/10.58837/chula.res.2006.76.

Full text
Abstract:
To investigate the effect of microwave cure and thermal cure in silicon carbide whisker (SiCw) filled in polybenzoxazine (PBZ) composite on its corresponding thermal and mechanical behaviors. SiC whisker is thus, used as a filler of the polybenzoxazine to enhance the microwave absorption capability of the molding compound and to reinforce the material. The experimental results reveal that the benzoxazine resin (BA-a) was hardly cured at a high power of 1 kW for 15 min. However, with a relatively low content at 4% by weight SiCw, the benzoxazine resin was found to be cured relatively well. Ther
APA, Harvard, Vancouver, ISO, and other styles
3

Sewell, Christopher Meyer. In-situ VPIC. Office of Scientific and Technical Information (OSTI), 2013. http://dx.doi.org/10.2172/1104911.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Stapp, P. In situ hydrogenation. Office of Scientific and Technical Information (OSTI), 1989. http://dx.doi.org/10.2172/5239585.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Chen, Wei-Ying, Yiren Chen, Peter Baldo, Lin Gao, Dzmitry Harbaruk, and Josh Hlavenka. In-situ and ex-situ characterization of irradiated AM materials. Office of Scientific and Technical Information (OSTI), 2024. http://dx.doi.org/10.2172/2447070.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Snead, Mary A., Yutai Katoh, Takaaki Koyanagi, and Gyanender P. Singh. SiC/SiC Cladding Materials Properties Handbook. Office of Scientific and Technical Information (OSTI), 2017. http://dx.doi.org/10.2172/1399957.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Youngblood, G. E., R. H. Jones, Akira Kohyama, et al. The HFIR 14J irradiation SiC/SiC composite and SiC fiber collaboration. Office of Scientific and Technical Information (OSTI), 1998. http://dx.doi.org/10.2172/330620.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Lara-Curzio, E. Optimization of Pseudo-Porous SiC Fiber Coatings for SiC/SiC Composites. Office of Scientific and Technical Information (OSTI), 2001. http://dx.doi.org/10.2172/777618.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Spiwoks, Markus, and Kilian Bizer. Zur Messung von Overconfidence - Eine experimentelle Studie. Sonderforschungsgruppe Institutionenanalyse, 2016. http://dx.doi.org/10.46850/sofia.9783941627574.

Full text
Abstract:
Diese Studie wendet sich zwei üblichen Verfahren zur Messung von Overconfidence zu und überprüft die Zuverlässigkeit dieser Verfahren. Es zeigt sich, dass die übliche Form der Abfrage der subjektiven Sicherheit bezüglich einer abgegebenen Prognose zu einer systematischen Überschätzung der Overconfidence beitragen kann. Außerdem zeigt sich, dass die übliche Form zur Erfassung der relativen Selbsteinschätzung ebenfalls zu einer Ergebnisverzerrung beitragen kann. Dies gilt insbesondere, wenn sich eine Probanden-gruppe nicht paritätisch aus Frauen und Männern zusammensetzt.
APA, Harvard, Vancouver, ISO, and other styles
10

Chen, Wei-Ying, Yiren Chen, Peter Baldo, Josh Hlavenka, and Dzmitry Harbaruk. In-situ and ex-situ characterization of ion-irradiated AM materials. Office of Scientific and Technical Information (OSTI), 2023. http://dx.doi.org/10.2172/1992453.

Full text
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!